gv-hd700 6 sm ver1.0

Upload: roberto-laterza

Post on 02-Jun-2018

247 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/10/2019 GV-HD700 6 SM ver1.0

    1/38

    SECTION 6

    ADJUSTMENTS

    ADJ

    Revision HistoryRevision History

    Link Link

    Adjusting items when replacing main parts and boards

    List of service tools

    Before starting adjustments

    PREPARATIONS BEFORE ADJUSTMENTS

    INITIALIZATION OF EVR DATA

    ADJUSTMENT PROGRAM

    LCD SYSTEM ADJUSTMENTS

    ORIGIN OSCILLATION CHECK

    LCD SECTION ADJUSTMENTS

    TAPE PATH ADJUSTMENT

    HOW TO ENTER PLAYBACK MODE WITHOUTCASSETTE

    HOW TO ENTER RECORD MODE WITHOUTCASSETTE

    MECHANISM SECTION ADJUSTMENTS

    AUDIO SYSTEM ADJUSTMENTS

    VIDEO SYSTEM ADJUSTMENTS

    SERVO AND RF SYSTEM ADJUSTMENTS

    SYSTEM CONTROL SYSTEM ADJUSTMENTS

    PREPARATIONS BEFORE ADJUSTMENTS

    VIDEO SECTION ADJUSTMENTS

    SERVICE MODE

    DATA PROCESS

    ADJUSTMENT REMOTE COMMANDER (RM-95)

    SERVICE MODE

    ADJUSTMENT REMOTE COMMANDER(NEW LANC JIG)

    APPLICATION OF ADJUSTMENT(SeusCam)

    Sony EMCS Co.GV-HD700/HD700E_ADJ

    NTSC MODEL: GV-HD700PAL MODEL: GV-HD700E

    GV-HD700/HD700RMT-844

    Ver. 1.0 2007.08

    2007H0800-1 2007.08

    Published by Kohde TEC9-852-218-51

  • 8/10/2019 GV-HD700 6 SM ver1.0

    2/386-1GV-HD700/HD700E_ADJ

    1. Before starting adjustments

    EVR Data Re-writing Procedure When Replacing BoardThe data that is stored in the repair board, is not necessarily correct.ily correct.

    Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.

    Procedure 1Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after aboard is replaced.

    Procedure 2Remove the EEPROM from the board of the machine that is going to be repaired. Install the removedEEPROM to the replaced board.

    Procedure 3When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed orinstalled, save the data from the same model of the same destination, and download it.

    After the EVR data is saved and downloaded, check therespective items of the EVR data.

    (Refer to page 6-3 for the items to be checked)

    Remove the EEPROM and install it.

    (Former board) (New board)

    (Machine before starting repair) (Machine after a board is replaced)PC PC

    Save the EVR datato a personal computer. . Download the saveddata to a machine. .

    (Machine to be repaired) (Machine to be repaired)

    (The same model of the same destination)

    Save the data

    Download the data

    PC

    SECTION 6ADJUSTMENTS

  • 8/10/2019 GV-HD700 6 SM ver1.0

    3/386-2GV-HD700/HD700E_ADJ

    1-1. Adjusting items when replacing main parts and boards Adjusting items when replacing main partsWhen replacing main parts, adjust the items indicated by z in the following table.Note 1: When replacing the drum assy or the mechanism deck, reset the data of page: 7, address: A8 to AB to 00. (Refer to Record of

    Use check (1) of 6-4. SERVICE MODE)

    Table 6-1-1 (1)

    LCD Panel driver video input level adj.V-COM adj.White balance adj.

    Mechanism Tape path adj.System control Node uniqe ID No. i nputServo, RF CAP FG duty adj.

    Switching position adj.

    Error rate check Video S VIDEO OUT Y level adj.

    S VIDEO OUT chroma level adj.COMPONENT OUT Y level adj.COMPONENT OUT Pr level adj.COMPONENT OUT Pb level adj.

    Initialization of Initialization of A, B, D, 1A, 1B page dataEVR da ta Initia lizat ion of 8, 9, C, 13, 18, 1C, 1D page data

    Adjustment Section Adjustment ( L C D p a n e

    l )

    ( D r u m a s s e m

    b l y )

    ( N o t e

    1 )

    L C D M o d u l e

    L C D 9 0 1

    M e c

    h a n i s m

    d e c k

    ( N o t e 1 )

    M e c

    h a n i s m

    d e c k

    M 9 0 1

    M e c

    h a n i s m

    d e c k

    M D

    b l o c

    k

    V D - 0

    3 8 b o a r

    d I C 1 8 0 1

    ( B a s e

    b a n d s i g n a l p r o c e s s , e t c .

    )

    V D - 0

    3 8 b o a r

    d I C 3 0 0 1

    ( D V s i g n a l p r o c e s s o r )

    V D - 0

    3 8 b o a r

    d I C 6 4 0 1

    ( V i d e o s i g n a l

    l i n e

    i n / o u t

    )

    V D - 0

    3 8 b o a r

    d I C 2 0 0 1

    ( D 4 d r i v e r

    )

    R P - 2 4 4 b o a r

    d I C 2 0 0 1

    ( R E C / P B a m p )

    P D - 3

    3 2 b o a r

    d I C 4 0 0 6

    ( L C D d r i v e )

    Replaced part

    Block replacement

    Mounted partreplacement

  • 8/10/2019 GV-HD700 6 SM ver1.0

    4/386-3GV-HD700/HD700E_ADJ

    Note 2: IC4406, IC5002 (Flash memory) on the VD-038 board cannot be replaced.

    Adjusting items when replacing EEPROMWhen replacing a board or EEPROM, adjust the items indicated by z in the following table.

    Replaced part

    Adjustment Section Adjustment ( E E P R O M )

    ( C o m p l e t e )

    V D - 0

    3 8 b o a r

    d I C

    4 4 0 6

    , 5 0 0 2

    V D - 0

    3 8 b o a r

    d

    ( C o m p l e t e )

    R P - 2

    4 4 b o a r

    d

    ( C o m p l e t e )

    P D - 3

    3 2 b o a r

    d

    S u p p o r

    t i n g

    Initialization of Initialization of A, B, D, 1A, 1B page dataEV R data Initialization of 8, 9, C, 13, 18, 1C, 1D page dataLCD Panel driver video input adj.

    V-COM adj.White balance adj.

    Mechanism Tape path adj.System control N ode uniqe ID No. inputServo, RF CAP FG duty adj.

    Switching position adj.Error rate check

    S VIDEO OUT Y level adj.S VIDEO OU T chroma level adj.COMPONENT OUT Y level adj.COMPONENT OUT Pr level adj.COMPONENT OUT Pb level adj.

    R a d a r W

    Table 6-1-1 (2)

    Video

  • 8/10/2019 GV-HD700 6 SM ver1.0

    5/386-4GV-HD700/HD700E_ADJ

    1-2. List of service tools Oscilloscope Color monitor Vectorscope Digital voltmeter Frequency counter Audio level meter Calculating machine capable of calculating hexadecimal numbers Camcorder

    Fig. 6-1-1

    Tracking standard(XH2-1)8-967-997-01

    SW/OL standard(XH2-3H)8-967-997-14

    Audio operation check

    for NTSC (XH5-3)8-967-997-51

    for PAL (XH5-3P)8-967-997-55

    J-13

    J-12J-10

    J-7 J-8 J-9

    J-11

    J-4

    Adjustment remotecommander(RM-95)J-6082-053-B

    System operation check

    for NTSC (XH5-5)

    8-967-997-61

    for PAL (XH5-5P)8-967-997-66

    AC power adaptor

    AC-L15A1-479-283-13

    AC-L1001-479-286-21or

    J-6J-5

    Adjustment remotecommander(NEW LANC JIG)J-6082-565-A

    J-1 J-3J-2

    Multi cable

    for serviceJ-6082-535-A

    LANC cableJ-6082-442-A

    A: CPC-15J-6082-564-A

    B: I/F unit forLANC controlJ-6082-521-A

    A

    B

    Personal computer(Note)

    HASP key and applicationfor adjustment (SeusCam)

    Contact our service headquater of each areahow to get the application for adjustment(SeusCam) and HASP key.

    USB cable1-829-868-41

    Note: Personal computerOS: Windows 98/98SE/ME/2000/XP Home/XP ProRAM: 256MB or more recommendedUSB: 2.0 recommended (also compatible with 1.1)

    Two connectors are required.

  • 8/10/2019 GV-HD700 6 SM ver1.0

    6/386-5

    GV-HD700/HD700E_ADJ

    6-1. LCD SECTION ADJUSTMENTS

    1-1. PREPARATIONS BEFORE ADJUSTMENTS

    1-1-1. PreparationsNote: Before perform the adjustment, check that the data of page:

    0, address: 10 is 00.If not, select page: 0, address: 10, and set data 00.

    1) Connect the equipment for adjustments according to Fig. 6-1-2.

    Fig. 6-1-2

    LANC jackA/V OUT

    (USB) jack

    DC IN jack

    Back ofLCD Module

    Back View

    Adjustment remotecommander

    (RM-95)

    (NEW LANC JIG)

    CN4006(FOR CHECK)

    1

    8

    PD-332 BOARD (SIDE A)

    Multi cable

    for service

    GNDGNDNCMONI_YNCMONI_PrNCMONI_Pb

    12345678

    AC IN

    AC adaptor

    PC (The SeusCam must be installed in the PCOS: Windows 98/98SE/ME/2000/XPRAM: 256MB or more recommendedUSB: 2.0 recommended (also compatible with 1.1) Two connectors are required.

    HASP Key

    USB cable(1-829-868-41)

  • 8/10/2019 GV-HD700 6 SM ver1.0

    7/386-6GV-HD700/HD700E_ADJ

    1-2. INITIALIZATION OF EVR DATANote 1: Pages used for the EVR consists of 12 pages. There are

    8, 9, A, B, C, D, 13, 18, 1A, 1B, 1C, 1D pages.Note 2: If 2-digit page is selected, set higher-order digit to page:

    0, address: 10 as data, and then select lower-order digitby a usual method.e.g.: Set data: 06 to page: 0, address: 10, and then selectpage: D. Thus, the page 6D can be selected.

    1-2-1. Initialization of A, B, D, 1A, 1B Page DataNote: Check that the data of page: 0, address: 10 is 00.

    1. Initializing of A, B, D, 1A, 1B Page DataNote: If the A, B, D, 1A, 1B page data has been initialized, the

    following adjustments need to be performed again.1) Modification of A, B, D, 1A, 1B page data

    Adjustment Page A

    Adjustment Address 10 to FF

    Adjustment Page B

    Adjustment Address 00 to FFAdjustment Page D

    Adjustment Address 10 to FF

    Adjustment Page 1A

    Adjustment Address 00 to FF

    Adjustment Page 1B

    Adjustment Address 00 to FF

    Initializing method:

    Order Page Address Data Procedure

    1 0 01 01

    2 0 10 00

    3 7 04Set the following data

    00: NTSC model01: PAL model

    Set the following data20: Initializing A page21: Initializing B page22: Initializing D page23: Initializing 1A page24: Initializing 1B page4 7 0125: Initializing A and 1A

    page

    26: Initializing B and 1Bpage

    28: Initializing A, B, D, 1Aand 1B page

    5 7 00 01 Press PAUSE (Write) button.

    6 7 02 Check the data changes to01.

    7 Perform Modification of A,B, D, 1A, 1B Page Data

    1-2-2. Initialization of 8, 9, C, 13, 18, 1C, 1D Page Data

    1. Initializing of 8, 9, C, 13, 18, 1C, 1D Page DataNote 1: If Initialization of Pages 8, 9, C, 13, 18, 1C, 1D is ex-

    ecuted, all data on pages 8, 9, C, 13, 18, 1C, 1D are ini-tialized. (Only an individual page cannot be initialized)

    Note 2: If the 8, 9, C, 13, 18, 1C, 1D page data has been initial-ized, the following adjustments need to be performedagain.1) Modification of 8, 9, C, 13, 18, 1C, 1D page data2) LCD system adjustments (if all areas were initial-

    ized)3) Node unique ID No. input (if all areas were initial-

    ized)4) Servo, RF system adjustments (if all areas were ini-

    tialized)5) Video system adjustments (if all areas were initial-

    ized)

    Adjustment Page 8

    Adjustment Address 00 to FF

    Adjustment Page 9

    Adjustment Address 00 to FF

    Adjustment Page C

    Adjustment Address 10 to FF

    Adjustment Page 13

    Adjustment Address 00 to FF

    Adjustment Page 18

    Adjustment Address 00 to FF

    Adjustment Page 1C

    Adjustment Address 00 to FF

    Adjustment Page 1DAdjustment Address 00 to FF

    Initializing method:

    Order Page Address Data Procedure

    1 0 01 01

    2 0 10 00

    Set the following data, andpress PAUSE (Write) button.(Note 3)

    3 3 81 00: Initializing all areas01: Initializing other than

    adjustment address

    4 3 80 0C Press PAUSE (Write) button.

    Check the data changes to5 3 801C.

    6Perform Modification of 8,9, C, 13, 18, 1C, 1D PageData

    Note 3: If other than adjustment address was initialized, the ad- justed data is not initialized.

  • 8/10/2019 GV-HD700 6 SM ver1.0

    8/386-7GV-HD700/HD700E_ADJ

    1-4. ORIGIN OSCILLATION CHECKCheck the frequency of the clock for synchronization.If deviated, the synchronization will be disrupted and the colorwill become inconsistent.

    Subject Not required

    Measurement Point VIDEO OUT

    Measuring Instrument Frequency counter

    Specified value f = 3.579545MHz 72 Hz (NTSC)f = 4.433619MHz 89 Hz (PAL)

    Checking method:1) Check that the frequency (f) satisfies the specified value.

    1-3. ADJUSTMENT PROGRAMThe GV-HD700/HD700E are adjusted by the Automatic Adjust-ment Program.The Automatic Adjustment Program enters automatically via theSeusCam the adjustment operations that were formerly enteredmanually by the adjustment remote commander (some items maybe adjusted by manual operation on the operation screen of theSeusCam).

    1. Precautions When Using Automatic Adjustment Program1) The Automatic Adjustment Program writes the adjustment

    results such as EVR data to the set through two-waycommunication with the camera via the SeusCam. Accordingly,the Automatic Adjustment Program must be used in theenvironment where the SeusCam operates.

    2) The Automatic Adjustment Program cannot be used when theSeusCam (digital camera adjustment software) is running. Exitthe SeusCam before using the Automatic Adjustment Program.

    3) The SeusCam must be already started on the PC when usingthe Automatic Adjustment Program. With the SeusCam not

    started, some adjustment items will take time in adjustment.4) The program run time may vary depending on theenvironment of the personal computer used.

    Note: Before using the Automatic Adjustment Program, set thefollowing data using the adjustment remote commander.

    1) Select page: 0, address: 01, and set data: 02) Select page: A, address: 15, set data: 01, and press the PAUSE

    button.These settings are released if the [END] button is clicked on theMain Menu screen of the Automatic Adjustment Program.

    2. Start of Automatic Adjustment ProgramUnzip the GV-HD700_LCD_Adj.zip. Double-click the applica-

    tion file (Ex.: LCD-1_Adj.vb e ), and the Automatic AdjustmentProgram will start.

    Adjustment

    Panel Driver VideoInput Level Adj. 1

    Panel Driver VideoInput Level Adj. 2V-Com Adj.White Balance Adj.

    AdjustmentProgram

    LCD-1_Adj.vb e

    LCD-2_Adj.vb e

    VCOM_Adj.vb eWB_Adj.vb e

    Adjusting AddressPage Address

    8 D8, D9, DA

    C 31, 45, 46

    C 3BC 41, 42, 43, 44

    1-5-3. Panel Driver Video Input Level Adjustment 1 (PD-332 board)Adjust the analog input signal (component) level to the panel driver.

    Mode VTR stop

    Signal No signal

    Measurement Point PD-332 board CN4006 (for check)

    Measuring Instrument Oscilloscope

    Adjustment Page 8

    Adjustment Address D8 (Y gain)

    D9 (Cr gain)

    DA (Cb gain)

    Specified Value All white signal waveform = 1Vp-p 40mV

    Fig. 6-1-1

    Adjusting method:1) Execute LCD-1_Adj.vb e . The window as shown below appears

    on the screen. Then click OK to start the adjustment.

    2) Program pauses and data input column window appears onthe screen as shown below. Then input data meets the speci-fied value and click OK button on the window.

    3) When the window as shown below appears on the screen, theadjustment is done and click OK on the message window.

    1-5. LCD SYSTEM ADJUSTMENTS

    Note 1: Taken an extreme care not to destroy the liquid crystaldisplay module by static electricity when replacing it.

    Note 2: Set the LCD BRIGHT, LCD COLOR to the centerNote 3: Open the LCD panel during the LCD system adjustment.

    1-5-1. Preparations1) Connect PC and others to the set as shown in Fig. 6-1-2.

    2) Execute SeusCam.3) Turn power on the set.4) Click Connect button on the SeusCam program screen.

    1-5-2. Adjustment Items and ProgramsThe adjustment items for LCD system are as listed in Table 6-1-1.

  • 8/10/2019 GV-HD700 6 SM ver1.0

    9/386-8GV-HD700/HD700E_ADJ

    Mode VTR stop

    Signal No signal

    Measurement PointCheck on LCD screenMeasuring Instrument

    Adjustment Page C

    Adjustment Address 31 (Y gain)

    45 (Cb gain)

    46 (Cr gain)

    Specified Value All white signal waveform = 1Vp-p 40mV

    1-5-4. Panel Driver Video Input Level Adjustment 2 (PD-332 board)Adjust the analog input signal (component) level to the panel driver.

    1-5-5. V-COM Adjustment (PD-332 board)Set the DC bias of the common electrode drive signal of LCD tothe specified value.If deviated, the LCD display will be move, producing flicker andconspicuous vertical lines.

    Adjusting method:1) Execute LCD-2_Adj.vb e . The window as shown below appears

    on the screen. Then click OK to start the adjustment.

    2) Adjustment goes automatically.3) When the window as shown below appears on the screen, the

    adjustment is done and click OK on the message window.

    LCD panel ofGV-HD700/HD700E Front of

    the lensVideo out jack

    Osilloscope

    L = Arbitrary

    L Camcorder

    LCD panel of GV-HD700/HD700E fullyappears on the LCD screen of Camcorder.

    Mode VTR stop

    Signal No signal

    Measurement PointCamcorder, OscilloscopeMeasuring Instrument

    Adjustment Page C

    Adjustment Address 3B

    Specified Value Waveform becomes minimum

    Note 1: Perform Panel Driver Video Input Level Adjustmentsbefore this adjustment.

    Note 2: Adjust in a dark place.

    Adjusting method:1) Execute VCOM_Adj.vb e . The window as shown below ap-

    pears on the screen. Then click OK to start the adjustment.

    2) After adjustment, the window as shown below appears on thescreen.Confirm the waveform and the specified value is satisfied, click No to quit the adjustment.In case of the specified value is not satisfied, click Yes tocontinue adjustment. Repeat it until the specified value is sat-isfied.

    In case of setting data is difficult, input the default value asfollows.

    Factory settingPage Address Data C 3B 40

    3) When the window as shown below appears on the screen, theadjustment is done and click OK on the message window.

  • 8/10/2019 GV-HD700 6 SM ver1.0

    10/386-9GV-HD700/HD700E_ADJ

    1-5-6. White Balance AdjustmentCorrect the white balance at transmissive mode.If deviated, the LCD screen color cannot be reproduced.

    Mode VTR stop

    Signal No signal

    Measurement Point Check on LCD screenMeasuring Instrument

    Adjustment Page C

    Adjustment Address 41 R_BIAS42 B_BIAS43 R_GAIN44 B_GAIN

    Specified Value Screen becomes white

    Note 1: Adjust in a dark place.Note 2: After adjustment, be sure to turn power off the set.

    Adjusting method:

    1) Execute WB_Adj.vb e . The window as shown below appearson the screen. Then click OK to start the adjustment.

    2) Program pauses and the data input column window appearson the screen as shown below. Then input data meets thespecified value and click OK button on the window.

    3) When the window as shown below appears on the screen, theadjustment is done and click OK onthe message window.

    4) Turn power off the set.

  • 8/10/2019 GV-HD700 6 SM ver1.0

    11/386-10GV-HD700/HD700E_ADJ

    6-2. MECHANISM SECTION ADJUSTMENTS

    On the mechanism section adjustmentFor details of mechanism section adjustments, checks, and replace-ment of mechanism parts, refer to the separate volume DV ME-CHANICAL ADJUSTMENT MANUAL IX N Mechanism .

    2-1. HOW TO ENTER RECORD MODEWITHOUT CASSETTE

    1) Connect the adjustment remote commander to the LANC jack.2) Turn the HOLD switch of the adjustment remote commander

    to the ON position.3) Close the cassette compartment without the cassette.4) Select page: 3, address: 01, set data: 0C, and press the PAUSE

    (Write) button of the adjustment remote commander.(The mechanism enters the record mode automatically.)Note: The function buttons become inoperable.

    5) To quit the record mode, select page: 3, address: 01, set data:00, and press the PAUSE (Write) button of the adjustment re-

    mote commander. (Whenever you want to quit the recordmode, be sure to quit following this procedure.)

    2-2. HOW TO ENTER PLAYBACK MODEWITHOUT CASSETTE

    1) Connect the adjustment remote commander to the LANC jack.2) Turn the HOLD switch of the adjustment remote commander

    to the ON position.3) Close the cassette compartment without the cassette.4) Select page: 3, address: 01, set data: 0B, and press the PAUSE

    (Write) button of the adjustment remote commander.(The mechanism enters the playback mode automatically.)Note: The function buttons become inoperable.

    5) To quit the playback mode, select page: 3, address: 01, setdata: 00, and press the PAUSE (Write) button of the adjust-ment remote commander. (Whenever you want to quit theplayback mode, be sure to quit following this procedure.)

    2-3. TAPE PATH ADJUSTMENT

    1. Preparation for Adjustment1) Clean the tape running side (tape guide, drum, capstan shaft,

    pinch roller, etc.).2) Connect the adjustment remote commander to the LANC jack.3) Turn the HOLD switch of the adjustment remote commander

    to the ON position.

    4) Connect an oscilloscope to RP-244 board CN1002 via tha CPC jig.Channel 1: RP-244 board CN1002 Pin 1 (Note)External trigger: RP-244 board CN1002 Pin 2 Note: Connect a 75 resistor between pins 1 and 8 of

    CN1002.75 resistor (Parts code: 1-247-804-11)

    5) Playback the alignment tape for tracking. (XH2-1)6) Select page: 3, address: 33, and set data: 08.7) Select page: 3, address: 26, set data: 31, and press the PAUSE

    (Write) button.8) Check that the oscilloscope RF waveform is normal at the en-

    trance and exit.If not normal, adjust according to the separate volume

    DV MECHANICAL ADJUSTMENT MANUAL IXN Mechanism .

    CN1002 of RP-244 board

    Pin No. Signal Name

    1 RF_MON

    2 SWP

    3 REG_GND

    4 N.C.

    5 N.C.

    6 N.C.

    7 N.C.

    8 REG_GND

    2. Procedure after operations1) Connect the adjustment remote commander to the LANC jack

    and set the HOLD switch to the ON position.2) Select page: 3, address: 26, set data: 00, and press the PAUSE

    (Write) button.3) Select page: 3, address: 33, and set data: 00.

    Fig. 6-2-1

    CH1

    Entrance side Exit sideCheck this section(Normal waveform)

    CH2(Trigger)

    3.3 msec

  • 8/10/2019 GV-HD700 6 SM ver1.0

    12/386-11GV-HD700/HD700E_ADJ

    6-3. VIDEO SECTION ADJUSTMENTS

    3-1. PREPARATIONS BEFORE ADJUSTMENTS

    3-1-1. Precautions on AdjustingNote: Before performing the adjustment, check the data of page:

    0, address: 10 is 00. If not, select page: 0, address: 00,and set data 00.

    3-1-2. Adjusting ConnectorsThe measuring point of the playback RF signal is CN1002 of RP-244 board. Connect the measuring instruments via the CPC jig. Refer to MECHANISM SECTION ADJUSTMENT for themeasuring method. The following table lists the pin numbers andsignal names of CN1002.

    Pin No. Signal Name

    1 RF_MON

    2 SWP

    3 REG_GND

    4 N.C.

    5 N.C.

    6 N.C.

    7 N.C.

    8 REG_GND

    Table 6-3-1

    Fig. 6-3-1

    3-1-3. Connecting the EquipmentConnect the measuring instruments as shown in Fig. 6-3-1, andperform the adjustments.

    A/V OUT jackAudio L (White)

    Audio R (Red)

    Video (Yellow)

    S Video (Black)

    COMPONENTOUT jack

    Pr (Red)

    Pb (Blue)

    Y (Green)

    AC IN

    DC IN jack

    VIDEO system adjustment (COMPONENT OUT)

    VIDEO system adjustment (S VIDEO, VIDEO)

    Osilloscope

    Terminated75

    Osilloscope

    Terminated75 ohm

    Adjustment remote commander

    RM-95NEW LANC JIG

    AC adaptorAC-L100 or AC-L15A

    Multi cablefor service

    1 8

    RP-244 BOARD(SIDE A)

    CPC-15

    I/F unit for LANC control

    CN1002

  • 8/10/2019 GV-HD700 6 SM ver1.0

    13/386-12GV-HD700/HD700E_ADJ

    3-1-4. Alignment TapesUse the alignment tapes shown in the following table.Use tapes specified in the signal column of each adjustment.

    Name Use

    Tracking standard (XH2-1) Tape path adjustment

    SW/OL standard (XH2-3H)Switching position adjust-ment

    Audio operation check Audio system adjustment(XH5-3(NTSC), XH5-3P(PAL))

    System operation check Operation check

    (XH5-5(NTSC), XH5-5P(PAL))

    Fig. 6-3-2 shows the 75% color bar signals recorded on the align-ment tape for Audio Operation Check.

    Note: Measure with video terminal (Terminated at 75 )

    Fig. 6-3-2 Color bar signal of alignment tapes

    For NTSC model

    For PAL model

    Color bar signal waveform Color bar pattern

    Color bar signal waveform Color bar pattern

    3-1-5. Output Level and Impedance

    1 V0.714 V

    0.286 V

    White (75%)

    White (100%)

    Y e l l o w

    C y a n

    G r e e n

    M a g e n t a

    R e d

    B l u e Burst signal

    0.286 V

    Q I

    Horizontal sync signal

    (75%) W

    h i t e

    Y e l l o w

    C y a n

    G r e e n

    M a g e n t a

    R e d

    B l u e

    Q I

    White(100%)

    Black

    1 V0.7 V

    0.3 V

    White (100%)

    Y e l l o w

    C y a n

    G r e e n

    M a g e n t a

    R e d

    B l u e

    Burst signalHorizontal sync signal

    0.3 V(100%)

    Y e l l o w

    C y a n

    G r e e n

    M a g e n t a

    R e d

    B l u e

    W h i t e

    B l a c k

    Audio/Video output10-pin connectorVideo signal: 1 Vp-p, 75 (ohms), unbalancedLuminance signal: 1 Vp-p, 75 (ohms), unbalancedChrominance signal: 0.286 Vp-p, 75 (ohms), un balanced (NTSC)Chrominance signal: 0.3 Vp-p, 75 (ohms), unbalanced (PAL)Audio signa l: 327 mV (at load impedance 47 k (kilohms)),Output impedance with less than 2.2 k (kilohms)

    COMPONENT OUT jackY: 1 Vp-p, 75 (ohms), unbalanced P B /PR, CB /CR: +/- 350 mVp-p

  • 8/10/2019 GV-HD700 6 SM ver1.0

    14/386-13GV-HD700/HD700E_ADJ

    D1 (decimal) D 2 (decimal) H 1 (hexadecimal)(Service model code)

    00001 to 65535 D 1 FE

    65536 to 131071 D 1 65536 FE

    131072 to196607 D 1 131072 FE

    196608 to 262143 D 1 196608 FE262144 to 327679 D 1 262144 FE

    327680 to 393215 D 1 327680 FE

    393216 to 458751 D 1 393216 FE

    458752 to 524287 D 1 458752 FE

    524288 to 589823 D 1 524288 FE

    589824 to 655359 D 1 589824 FE

    655360 to 720895 D 1 655360 FE

    720896 to 786431 D 1 720896 FE

    786432 to 851967 D 1 786432 FE

    851968 to 917503 D 1 851968 FE

    917504 to 983039 D 1 917504 FE

    983040 to 999999 D 1 983040 FE

    Table 6-3-2

    4) Enter H 1 to address: 09 on page: 13.Example: If H 1 = FE,Select page: 0, address: 10, and set data: 01.Select page: 3 (13), address: 09, and set data: FE, then pressthe PAUSE (Write) button.

    5) From Table 6-3-3, obtain the maximum decimal number lessthan D 2, and it is assumed to be D 3.Example: If D 2 = 12345.

    D3 = 122886) From Table 6-3-3, obtain a hexadecimal number that corre-sponds to D 3, and it is assumed to be H 3.Example: If D 3 = 12288,

    H3 = 30007) C al uc ul at e D 4 using following equations (decimal

    caluculation). (0 D 4 225)D4 = D 2D 3

    Example: If D 2 = 12345 and D 3 = 12288,D4 = 12345 12288 = 57

    8) Convert D 4 into a hexadecimal number to obtain H 4. (See Table6-4-1 "Hexadecimal - decimal conversion table" in 6-4. Ser-vice Mode)

    -

    Example: If D 4 = 57,

    H4 = 399) Enter higher two digits of H 3 to address: 0A on page: 13.

    Example: If H 3 = 3000,Select page: 0, address: 10, and set data: 01.Select page: 3 (13), address: 0A, and set data: 30, then pressthe PAUSE (Write) button.

    the PAUSE (Write) button.

    10) Enter H 4 to address: 0B on page: 13.Example: If H 4 = 39,Select page: 0, address: 10, and set data: 01.Select page: 3 (13), address: 0B, and set data: 39, then press

    11) Select page: 0, address: 10, and set data: 00.12) Select page: 0, address: 01, and set data: 00.

    3-2. SYSTEM CONTROL SYSTEM ADJUSTMENTS

    1. Initialization of EEPROM DataIf the EEPROM data is erased due to some reason, perform "1-2.INITIALIZATION OF EEPROM DATA", of "6-1. LCD SECTIONADJUSTMENTS".

    2. Node Unique ID No. InputNote 1: Perform "2-2. Input of Serial No." if the data on page 13

    has been cleared and original node unique ID No. is un-certain.Usually read the data on page 13 before repair, and writeit after repair.

    ,.

    Note 2: If reading/writing data on pages 13, set data: 01 to page:0, address: 10, and then select pages: 3. By this data set-ting, the pages 13 can be selected.After the data reading/writing finished, return the dataon page: 0, address: 10 to "00".

    2-1. Input of Company ID

    Write the company ID to the EEPROM (nonvolatile memory).Page 13

    Address 04, 05, 06, 07, 08

    Input method:1) Select page: 0, address: 01, and set data: 01.2) Select page: 0, address: 10, and set data: 01.3) Select page: 3 (13), and enter the following data.Note 3: Each time the data is set, press the PAUSE (Write) but-

    ton on the adjusting remote commander.

    Address Data

    04 08

    05 0006 46

    07 01

    08 02

    4) Select page: 0, address: 10, and set data: 00.5) Select page: 0, address: 01, and set data: 00.

    2-2. Input of Serial No.Write the serial No. and model code to the EEPROM (nonvolatilememory).In writing the serial No., a decimal number should be convertedinto a hexadecimal number.

    Page 13

    Address 09, 0A, 0B

    1) Select page: 0, address: 01, and set data: 01.2) Read the serial No. from the model name label, and it is as-

    sumed to be D 1.Example: If serial No. is "77881",

    D1 = 778813) From Table 6-3-2, obtain D 2 and H 1 that correspond to D 1.

    Example: If D 1 = 77881,D2 = D 165536 = 12345H1 = FE

  • 8/10/2019 GV-HD700 6 SM ver1.0

    15/386-14GV-HD700/HD700E_ADJ

    D3 H3 D3 H3 D30 0000 8192 2000 16384 4000 24576 6000 32768 8000 40960 A000 49152 C000 57344 E000

    256 0100 8448 2100 16640 4100 24832 6100 33024 8100 41216 A100 49408 C100 57600 E100

    512 0200 8704 2200 16896 4200 25088 6200 33280 8200 41472 A200 49664 C200 57856 E200

    768 0300 8960 2300 17152 4300 25344 6300 33536 8300 41728 A300 49920 C300 58112 E300

    1024 0400 9216 2400 17408 4400 25600 6400 33792 8400 41984 A400 50176 C400 58368 E400

    1280 0500 9472 2500 17664 4500 25856 6500 34048 8500 42240 A500 50432 C500 58624 E500

    1536 0600 9728 2600 17920 4600 26112 6600 34304 8600 42496 A600 50688 C600 58880 E600

    1792 0700 9984 2700 18176 4700 26368 6700 34560 8700 42752 A700 50944 C700 59136 E700

    2048 0800 10240 2800 18432 4800 26624 6800 34816 8800 43008 A800 51200 C800 59392 E800

    2304 0900 10496 2900 18688 4900 26880 6900 35072 8900 43264 A900 51456 C900 59648 E900

    2560 0A00 10752 2A00 18944 4A00 27136 6A00 35328 8A00 43520 AA00 51712 CA00 59904 EA00

    2816 0B00 11008 2B00 19200 4B00 27392 6B00 35584 8B00 43776 AB00 51968 CB00 60160 EB00

    3072 0C00 11264 2C00 19456 4C00 27648 6C00 35840 8C00 44032 AC00 52224 CC00 60416 EC00

    3328 0D00 11520 2D00 19712 4D00 27904 6D00 36096 8D00 44288 AD00 52480 CD00 60672 ED00

    3584 0E00 11776 2E00 19968 4E00 28160 6E00 36352 8E00 44544 AE00 52736 CE00 60928 EE00

    3840 0F00 12032 2F00 20224 4F00 28416 6F00 36608 8F00 44800 AF00 52992 CF00 61184 EF00

    4096 1000 12288 3000 20480 5000 28672 7000 36864 9000 45056 B000 53248 D000 61440 F000

    4352 1100 12544 3100 20736 5100 28928 7100 37120 9100 45312 B100 53504 D100 61696 F100

    4608 1200 12800 3200 20992 5200 29184 7200 37376 9200 45568 B200 53760 D200 61952 F200

    4864 1300 13056 3300 21248 5300 29440 7300 37632 9300 45824 B300 54016 D300 62208 F300

    5120 1400 13312 3400 21504 5400 29696 7400 37888 9400 46080 B400 54272 D400 62464 F400

    5376 1500 13568 3500 21760 5500 29952 7500 38144 9500 46336 B500 54528 D500 62720 F500

    5632 1600 13824 3600 22016 5600 30208 7600 38400 9600 46592 B600 54784 D600 62976 F600

    5888 1700 14080 3700 22272 5700 30464 7700 38656 9700 46848 B700 55040 D700 63232 F700

    6144 1800 14336 3800 22528 5800 30720 7800 38912 9800 47104 B800 55296 D800 63488 F800

    6400 1900 14592 3900 22784 5900 30976 7900 39168 9900 47360 B900 55552 D900 63744 F900

    6656 1A00 14848 3A00 23040 5A00 31232 7A00 39424 9A00 47616 BA00 55808 DA00 64000 FA00

    6912 1B00 15104 3B00 23296 5B00 31488 7B00 39680 9B00 47872 BB00 56064 DB00 64256 FB00

    7168 1C00 15360 3C00 23552 5C00 31744 7C00 39936 9C00 48128 BC00 56320 DC00 64512 FC00

    7424 1D00 15616 3D00 23808 5D00 32000 7D00 40192 9D00 48384 BD00 56576 DD00 64768 FD00

    7680 1E00 15872 3E00 24064 5E00 32256 7E00 40448 9E00 48640 BE00 56832 DE00 65024 FE00

    7936 1F00 16128 3F00 24320 5F00 32512 7F00 40704 9F00 48896 BF00 57088 DF00 65280 FF00

    H3 D3 H3 D3 H3 D3 H3 D3 H3 D3 H3

    Note: D 3: DecimalH3: Hexadecimal

    Table 6-3-3

  • 8/10/2019 GV-HD700 6 SM ver1.0

    16/386-15GV-HD700/HD700E_ADJ

    Input method:1) Select page: 0, address: 01, and set data: 01.2) Select page: B, and enter the following data.Note 5: Each time the data is set, press the PAUSE (Write) but-

    ton on the adjusting remote commander.

    Address Data

    D6 First and first 2nd digits of serial numberD7 First 3rd and 4th digits of serial number

    D8 First 5th and 6th digits of serial number

    D9 First 7th and 8th digits of serial number

    Note 6: If the serial number is less than 8 digits, set "0" at the topof serial number by the amount of shortage of digits.

    Example: If the serial number is "1234567", set "01234567".D6 = 01D7 = 23D8 = 45D9 = 67

    3) Select page: 0, address: 01, and set data: 00.

    Charactor ! " # $ % & ' ( )

    ASCII Code 20 21 22 23 24 25 26 27 28 29

    Charactor * + , - . /

    ASCII Code 2a 2b 2c 2d 2e 2f

    Charactor 0 1 2 3 4 5 6 7 8 9

    ASCII Code 30 31 32 33 34 35 36 37 38 39

    Charactor : ; < = > ?

    ASCII Code 3a 3b 3c 3d 3e 3f

    Charactor @ A B C D E F G H I

    ASCII Code 40 41 42 43 44 45 46 47 48 49

    Charactor J K L M N O

    ASCII Code 4a 4b 4c 4d 4e 4f

    Charactor P Q R S T U V W X Y

    ASCII Code 50 51 52 53 54 55 56 57 58 59

    Charactor Z [ ] ^ _

    ASCII Code 5a 5b 5c 5d 5e 5f

    Charactor ` a b c d e f g h i

    ASCII Code 60 61 62 63 64 65 66 67 68 69

    Charactor j k l m n o

    ASCII Code 6a 6b 6c 6d 6e 6f Charactor p q r s t u v w x y

    ASCII Code 70 71 72 73 74 75 76 77 78 79

    Charactor z { | } ~

    ASCII Code 7a 7b 7c 7d 7e

    2-2.USB Serial Number Data SettingSet the serial number data of the USB.

    Note 1: Before the repair, read the data of the set to be repaired,and write the read data after the repair.Perform "3-1. Moodel Number Input" and "3-2. SerialNumber Input", if the data on page B is erased and origi-nal USB serial number si unknown.

    e ,

    Note 2: Check that the data of page: 0, address: 10 is "00".

    3-1. Model Number InputWrite the model number to the EEPROM (nonvolatle memory).For the model number, enter the ASCII codes that correspond tothe last 5 characters of the model name given on the model namelabel of the set.

    Page B

    Address D1, D2, D3, D4, D5

    Input method:

    1) Select page: 0, address: 01, and set data: 01.2) Select page: B, and enter the following data.Note 3: Each time the data is set, press the PAUSE (Write) but-

    ton on the adjusting remote commander. .

    Address Data

    D1 Last 5th character on model name label (Note 4)

    D2 Last 4th character on model name label

    D3 Last 3rd character on model name label

    D4 Last 2nd character on model name label

    D5 Last character on model name label

    Note 4: If the model name is less than 5 characters, justify the

    codes to the right and set "20" for the remainder. .

    Example: If the model name is"GV-HD700", set "4844373030".

    D1 = 48D2 = 44D3 = 37D4 = 30D5 = 30

    "GV-HD700E", set "4437303045".D1 = 44D2 = 37D3 = 30D4 = 30D5 = 45

    3) Select page: 0, address: 01, and set data: 00.

    Table 6-3-4

    3-2. Serial Number InputWrite the serial number to the EEPROM (nonvolatile memory).For the serial number, set the serial number given on the modelname label of the set.

    Page B

    Address D6, D7, D8, D9

  • 8/10/2019 GV-HD700 6 SM ver1.0

    17/386-16GV-HD700/HD700E_ADJ

    1. CAP FG Duty Adjustment (RP-244 board)RadarW adarRadarW adarRadarW

    Set the CAP FG signal duty cycle to 50% to establish an appropri-ate capstan servo. If deviated, the uneven rotation of capstan andnoise can occur.

    Mode VTR stop

    Signal No signal

    Measurement Point Displayed data of page: 3, address:03

    Measuring Instrument Adjusting remote commander

    Adjustment Page C

    Adjustment Address 16

    Specified value The data of page: 3, address: 03 is 00

    Note 1: Check that the data of page: 0, address: 10 is 00 .

    Adjusting method:

    Order Page Address Data Procedure

    1Close the cassette compart-ment without insertingcassette.

    2 0 01 01

    3 3 03 FF

    4 3 01 1B Press PAUSE (Write) button.

    5 3 02Check the data changes inthe following order 1B t 2B t 00

    6 3 03 Check the data is 00 . (Note 2)

    7 0 01 00Note 2: If the data is 01 , adjustment has errors or the mecha-

    nism deck is defective.If the data is 80 , the mechanism deck is in emergencystate or the end of tape was detected.

    3-3. SERVO AND RF SYSTEM ADJUSTMENTSBefore perform the servo and RF system adjustments, check thatthe specified values of Origin Oscillation check is satisfied.Check that the data of page: 0, address: 10 is 00 . If not, selectpage: 0, address: 10, and set the data 00 .

    Adjusting Procedure:1. CAP FG duty adjustment2. Switching position adjustment3. Error rate check

  • 8/10/2019 GV-HD700 6 SM ver1.0

    18/386-17GV-HD700/HD700E_ADJ

    Note 3: If bit0 of the data is 1 , the EVEN channel is defective.If bit1 of the data is 1 , the ODD channel is defective.Contents of the defect is see written into page: C, ad-dress: 10 and 12. See following table.(For the bit values, refer to 6-4. SERVICE MODE , 4-4. 3. Bit value discrimination .)If bit3 of the data is 1 , the tape end being played, sorewind the tape and perform the adjustment again.

    When the EVEN channel is defective

    Data of page: C, Contents of defectaddress: 10

    EE Writing into Flash memory (IC2601) isdefective

    E8 Adjustment data is out of range

    E7 No data is returned from IC3001

    When the ODD channel is defective

    Data of page: C, Contents of defectaddress: 12

    EE Writing into Flash memory (IC2601) isdefective

    E8 Adjustment data is out of range

    E7 No data is returned from IC3001

    2. Switching Position Adjustment (RP-244 board) adaradarRadarW

    Mode VTR playback (VCR mode)

    Signal SW/OL standard (XH2-3)

    Measurement Point Displayed data of page: 3, address:

    03Measuring Instrument Adjusting remote commander

    Adjustment Page C

    Adjustment Address 10, 11, 12, 13

    Specified value The data of page: 3, address: 03 is 00

    Note 1: Check that the data of page: 0, address: 10 is 00 .

    Adjusting method:

    Order Page Address Data Procedure

    1

    Insert the SW/OL standard

    tape and enter the VTR stopmode.

    2 0 01 01

    3 C 10 EE Press PAUSE (Write) button.

    4 3 03 FF

    5 3 21 Check the data is 02 . (Note 2)

    6 3 01 0D Press PAUSE (Write) button.

    7 3 02 Check the data changes to 00 .

    8 3 03 Check the data is 00 . (Note 3)

    9 0 01 00

    Note 2: If the data is 72 , the tape top being played. After play-ing the tape for 1 to 2 seconds, stop it, perform step 5 andhigher.If the data is 62 , the tape end being played. After re-wind the tape, perform step 5 and higher.

  • 8/10/2019 GV-HD700 6 SM ver1.0

    19/386-18GV-HD700/HD700E_ADJ

    3. Error Rate Check (RP-244 board) RadarW adarRadarW adarRadarW

    Note: Check that the data of page: 0, address: 10 is 00.

    3-1. Preparations before adjustments

    Mode Recording

    Subject Arbitrary

    Switch setting1) REC FORMAT (Menu setting) ........................................ DV

    Adjusting method:

    Order Page Address Data Procedure

    1 0 01 01

    2 0 10 01

    3 C 0D C8 Press PAUSE (Write) button.(1C)

    4 0 10 00

    5 Record for 2 minutes.

    3-2. Error Rate Check

    Mode VTR playback

    Subject Recorded signal at Preparationsbefore adjustments

    Measurement Point Displayed data of page: 3, address:03

    Measuring Instrument Adjusting remote commander

    Adjustment Page 1C

    Adjustment Address B3 to C8

    Specified value The data of page: 3, address: 03 is00

    Note 1: If reading/writing data on pages 1C, set data: 01 to page:0, address: 10, and then select pages: C. By this data set-ting, the pages 1C can be selected.After the data reading/writing finished, return the dataon page: 0, address: 10 to 00.

    Initial Value of Page 1C: Address: B3 to C8

    Address Initial Address Initial Address Initialvalue value value

    B3 00 BB 00 C3 80

    B4 00 BC 00 C4 00B5 00 BD 00 C5 00

    B6 00 BE 00 C6 00

    B7 00 BF 00 C7 00

    B8 80 C0 00 C8 00

    B9 00 C1 00

    BA 00 C2 00

    Table 6-3-5

    Adjusting method:

    Order Page Address Data Procedure

    1 0 01 01

    2

    Check that the data of page:1C, address: B3 to C8 is theinitial value. (See Table 6-3-4)

    3Playback the recorded signalat Preparations beforeadjustments.

    4 3 03 FF

    5 3 01 40 Press PAUSE (Write) button.

    6 3 02 Check the data changes to00.

    7 3 03 Check the data is 00. (Note 2)

    8 Perform Processing afterCompleting Adjustments.

    Note 2: If the data is other than 00, Error rate is abnormal.For the contents of the abnormality, see the followingtable.

    Data of page: 3, Contents of defectaddress: 03

    01 EVEN channel is abnormal.

    02 ODD channel is abnormal.

    03 EVEN channel and ODD channel areabnormal.

    Note 3: If Error rate is abnormal, Check the use tape, clean thetape running surface. And after inputting initial values topage 1C: address: B3 to C8, perform re-adjustment. (SeeTable 6-3-4)

    Processing after Completing Adjustment:

    Order Page Address Data Procedure

    1 0 01 01

    2 0 10 01

    3 C 0D 00 Press PAUSE (Write) button.(1C)

    4 0 10 00

    5 0 01 00

  • 8/10/2019 GV-HD700 6 SM ver1.0

    20/386-19GV-HD700/HD700E_ADJ

    1-2. S VIDEO OUT Y Level Adjustment (VD-038 board)

    Mode VCR

    Signal No signal

    Measurement Point Y signal terminal of S VIDEO plugof A/V jack (75 terminated)

    Measuring Instrument OscilloscopeAdjustment Page C

    Adjustment Address 90 (NTSC)8A (PAL)

    Specified value A = 1000 14 mVp-p

    Adjusting method:

    Order Page Address Data Procedure

    1 Perform Preparations .

    2 CChange the data and set the Ysignal level (A) to the

    specified value.

    3 C Press PAUSE (Write) button.

    4 Perform Processing after

    Complete Adjustment .

    3-4. VIDEO SYSTEM ADJUSTMENTSBefore perform the video system adjustments, check that the speci-fied values of Origin Oscillation Check is satisfied.Check that the data of page: 0, address: 10 is 00 .If not, select page: 0, address: 10, and set the data 00 .

    Adjusting Procedure:1. S VIDEO OUT Y level adjustment2. S VIDEO OUT chroma level adjustment3. VIDEO OUT level check 4. COMPONENT OUT Y level adjustment5. COMPONENT OUT Pr level adjustment6. COMPONENT OUT Pb level adjustment

    1. S VIDEO, VIDEO OUT Adjustment1-1. PreparationsPerform the following data setting before the S VIDEO,VIDEO OUT Adjustment .

    Order Page Address Data Procedure

    1 Set the unit to VCR mode.

    2 0 01 01

    3 0 10 01

    4 8 00 01 Press PAUSE (Write) button.(18)

    5 8 01 60 Press PAUSE (Write) button.(18)

    6 C 0F 10 Press PAUSE (Write) button.(1C)

    7 8 06 55 Press PAUSE (Write) button.(18)

    8 8 04 C0 Press PAUSE (Write) button.(18)

    9 0 10 00

    10 Wait for 5 sec.

    11 0 FF 3E

    12 B 00 02

    13 C 85 Check the data is 55 .

    14 B 00 00

    15 0 FF 00Fig. 6-3-3

    H

    A

    (NTSC)90

    (PAL)8A(NTSC)

    90(PAL)

    8A

  • 8/10/2019 GV-HD700 6 SM ver1.0

    21/386-20GV-HD700/HD700E_ADJ

    H

    A

    0.28 sec (NTSC)

    B

    0.28 sec (NTSC)0.23 sec (PAL) 0.23 sec (PAL)

    C

    Fig. 6-3-4

    1-3. S VIDEO OUT Chroma Level Adjustment(VD-038 board)

    Mode VCR

    Signal No signal

    Measurement Point Chroma signal terminal of S VIDEOplug of A/V jack (75 terminated)External trigger: Y signal terminal of S VIDEO plug of A/V jack (75 terminated)

    Measuring Instrument Oscilloscope

    Adjustment Page C

    Adjustment Address 91, 92 (NTSC)8B, 8C (PAL)

    Specified value Cr level: A = 714 14 mVp-p(NTSC)A = 700 14 mVp-p(PAL)

    Cb level: B = 714 14 mVp-p(NTSC)B = 700 14 mVp-p(PAL)

    Burst level: C = 286 6 mVp-p(NTSC)

    C = 300 6 mVp-p(PAL)

    Adjusting method:

    Order Page Address Data Procedure

    1 Peform Preparations.

    2 CChange the data and set theCr signal level (A) to thespecified value.

    3 C Press PAUSE (Write) button.

    4 CChange the data and set theCb signal level (B) to thespecified value.

    5 C Press PAUSE (Write) button.

    6 Check the burst signal (C) tothe specified value.

    7 Perform Processing after

    Complete Adjustment.

    (NTSC)91

    (PAL)8B

    (NTSC)91

    (PAL)8B

    (NTSC)92

    (PAL)8C

    (NTSC)92

    (PAL)8C

  • 8/10/2019 GV-HD700 6 SM ver1.0

    22/386-21GV-HD700/HD700E_ADJ

    1-5. Processing after Complete AdjustmentPerform the setting through the procedure mentioned below whenyou finish the S VIDEO, VIDEO OUT Adjustment.

    Order Page Address Data Procedure

    1 0 10 01

    2C

    0F 00 Press PAUSE (Write) button.(1C)

    3 8 04 80 Press PAUSE (Write) button.(18)

    4 8 00 00 Press PAUSE (Write) button.(18)

    5 8 01 00 Press PAUSE (Write) button.(18)

    6 8 06 00 Press PAUSE (Write) button.(18)

    7 0 10 00

    8 0 01 00

    1-4. VIDEO OUT Level Check (VD-038 board)

    Mode VCR

    Signal No signal

    Measurement Point Video terminal of A/V jack (75 terminated)

    Measuring Instrument OscilloscopeSpecified value Sync level: A = 286 18 mVp-p(NTSC)

    A = 300 18 mVp-p(PAL)Burst level: B = 286 18 mVp-p(NTSC)

    B = 300 18 mVp-p(PAL)

    Checking method:

    Order Page Address Data Procedure

    1 Peform Preparations

    2 Check the sync signal level(A) to the specified value.

    3Check the burst signal level(B) to the specified value.

    4 Perform Processing afterComplete Adjustment.

    Fig. 6-3-5

    H

    B

    A

  • 8/10/2019 GV-HD700 6 SM ver1.0

    23/386-22GV-HD700/HD700E_ADJ

    3. COMPONENT OUT Pr Level Adjustment(VD-038 board)

    Mode REC

    Subject Arbitrary

    Measurement Point Pr signal terminal of COMPONENTOUT jack (75 terminated)

    Measuring Instrument Oscilloscope

    Adjustment Page C

    Adjustment Address 95

    Specified value Pr level: A = 525 10 mVp-pSync level: B = C = 300 10 mVp-p

    Switch setting:1) REC FORMAT (Menu setting) ............................. HDV1080i

    Adjusting method:

    Order Page Address Data Procedure

    1 0 01 01

    2 0 10 01

    3 8 00 Set the bit value of bit7 is1, and press PAUSE(18)(Write) button. (Note)

    4 0 10 00

    5 C 95Change the data and set thePr signal level (A) to thespecified value.

    6 C 95 Press PAUSE (Write) button.

    7 Check the sync signal (B, C)to the specified value.

    8 0 10 01

    9 8 00 Set the bit value of bit7 is0, and press PAUSE(18)(Write) button. (Note)

    10 0 10 00

    11 0 01 00

    Note: For the bit values, refer to 6-4. SERVICE MODE ,4-4. 3. Bit value discrimination .

    Fig. 6-3-7

    H

    A

    C

    B

    2. COMPONENT OUT Y Level Adjustment(VD-038 board)

    Mode REC

    Subject Arbitrary

    Measurement Point Y signal terminal of COMPONENTOUT jack (75 terminated)

    Measuring Instrument Oscilloscope

    Adjustment Page C

    Adjustment Address 93

    Specified value Y level: A = 1000 10 mVp-pSync level: B = C = 300 10 mVp-p

    Switch setting:1) REC FORMAT (Menu setting) ............................. HDV1080i

    Adjusting method:

    Order Page Address Data Procedure

    1 0 01 01

    2 0 10 01

    3 8 00 Set the bit value of bit7 is1, and press PAUSE(18)(Write) button. (Note)

    4 0 10 00

    5 C 93Change the data and set the Ysignal level (A) to thespecified value.

    6 C 93 Press PAUSE (Write) button.

    7 Check the sync signal (B, C)to the specified value.

    8 0 10 01

    9 8 00 Set the bit value of bit7 is0, and press PAUSE(18)(Write) button. (Note)

    10 0 10 00

    11 0 01 00

    Note: For the bit values, refer to 6-4. SERVICE MODE ,4-4. 3. Bit value discrimination .

    Fig. 6-3-6

    H

    A

    C

    B

  • 8/10/2019 GV-HD700 6 SM ver1.0

    24/386-23GV-HD700/HD700E_ADJ

    H

    A

    C

    B

    4. COMPONENT OUT Pb Level Adjustment(VD-038 board)

    Mode REC

    Subject Arbitrary

    Measurement Point Pb signal terminal of COMPONENTOUT jack (75 terminated)

    Measuring Instrument Oscilloscope

    Adjustment Page C

    Adjustment Address 94

    Specified value Pb level: A = 525 10 mVp-pSync level: B = C = 300 10 mVp-p

    Switch setting:1) REC FORMAT (Menu setting) ............................. HDV1080i

    Adjusting method:

    Order Page Address Data Procedure

    1 0 01 01

    2 0 10 01

    3 8 00 Set the bit value of bit7 is1, and press PAUSE(18)(Write) button. (Note)

    4 0 10 00

    5 C 94 Change the data and set thePb signal level (A) to thespecified value.

    6 C 94 Press PAUSE (Write) button.

    7 Check the sync signal (B, C)to the specified value.

    8 0 10 01

    9 8 00 Set the bit value of bit7 is0, and press PAUSE(18)(Write) button. (Note)

    10 0 10 00

    11 0 01 00

    Note: For the bit values, refer to 6-4. SERVICE MODE , 4-4.3. Bit value discrimination .

    Fig. 6-3-8

  • 8/10/2019 GV-HD700 6 SM ver1.0

    25/386-24GV-HD700/HD700E_ADJ

    3-5. AUDIO SYSTEM ADJUSTMENTS

    [Connecting the measuring instruments for the audio]Connect the audio system measuring instruments in addition tothe video system measuring instruments as shown in Fig. 6-3-9.

    Fig. 6-3-9

    1. Playback Level Check

    Mode VTR playback

    SignalAlignment tape:

    For audio operation check (XH5-3 (NTSC))(XH5-3P (PAL))

    Measurement Point Audio left or right terminal of A/V jack

    Measuring Instrument Audio level meter and frequencycounter

    Specified Value

    32 kHz mode: 1 kHz, + 3.0 2.0 dBs48 kHz mode: 1 kHz, + 3.0 2.0 dBs44.1 kHz mode:The 7.35 kHz signal level during EMPOFF is +2.0 2.0 dBs.The 7.35 kHz signal level during EMPON is 6 2 dB from the signal levelduring EMP OFF.

    Checking Method:1) Check that the playback signal level is the specified value.

    A/V jack Audio (L)

    Audio (R)

    Audio level meter

    In Playback

    Main unit

  • 8/10/2019 GV-HD700 6 SM ver1.0

    26/386-25GV-HD700/HD700E_ADJ

    6-4. SERVICE MODE

    4-1. ADJUSTMENT REMOTE COMMANDER(RM-95)

    The adjustment remote commander (RM-95) is used for changingthe calculation coefficient in signal processing, EVR data, etc. The

    adjustment remote commander (RM-95) performs bi-directionalcommunication with the unit using the remote commander signalline (LANC). The resultant data of this bi-directional communica-tion is written in the non-volatile memory.

    1. Using the Adjustment Remote Commander (RM-95)1) Connect the adjustment remote commander to the LANC ter-

    minal.2) Set the HOLD switch of the adjustment remote commander

    (RM-95) to HOLD (SERVICE position). If it has been prop-erly connected, the LCD on the adjustment remote commander(RM-95) will display as shown in Fig. 6-4-1.

    Fig. 6-4-1

    3) Operate the adjustment remote commander (RM-95) as fol-lows. Changing the page

    The page increases when the EDIT SEARCH+ button ispressed, and decreases when the EDIT SEARCH button ispressed. There are altogether 16 pages, from 0 to F.

    Changing the addressThe address increases when the FF ( M ) button is pressed,and decreases when the REW ( m ) button is pressed. Thereare altogether 256 addresses, from 00 to FF.

    Changing the data (Data setting)The data increases when the PLAY ( N ) button is pressed,and decreases when the STOP ( x ) button is pressed. Thereare altogether 256 data, from 00 to FF.

    Writing the adjustment dataThe PAUSE button must be pressed to write the adjustmentdata in the nonvolatile memory. (The new adjusting datawill not be recorded in the nonvolatile memory if this stepis not performed)

    4) After completing all adjustments, turn off the main power sup-ply (8.4 V) once.

    Page Data Address

    HexadecimalnotationLCD DisplayDecimal notationconversion value

    0 1 2 3 4 5 6 7 8 9 A B C D E F

    0 1 2 3 4 5 6 7 8 9 A b c d E F

    0 1 2 3 4 5 6 7 8 9 10 11 12131415

    2. Precautions Upon Using the Adjustment RemoteCommander (RM-95)

    Mishandling of the adjustment remote commander may erase thecorrect adjustment data at times. To prevent this, it is recommendedthat all adjustment data be noted down before beginning adjust-ments and new adjustment data after each adjustment.

  • 8/10/2019 GV-HD700 6 SM ver1.0

    27/386-26GV-HD700/HD700E_ADJ

    4-2. ADJUSTMENT REMOTE COMMANDER (NEW LANC JIG)

    The adjustment remote commander (New LANC Jig) is used forchanging the calculation coefficient in signal processing, EVR data,etc. The adjustment remote commander (New LANC Jig) performsbi-directional communication with the unit using the remote com-mander signal line (LANC). The resultant data of this bi-direc-tional communication is written in the non-volatile memory.

    1. Using the Adjustment Remote Commander(New LANC Jig))

    1) Connect the adjustment remote commander (New LANC Jig)to the LANC terminal via the LANC cable (J-6082-442-A).

    2) Set the slide switch of the adjustment remote commander (NewLANC Jig) to SERVICE (SERVICE position). If it has beenproperly connected, the LCD on the adjustment remote com-mander (New LANC Jig) will display as shown in Fig. 6-4-2.

    Fig. 6-4-2

    3) Operate the adjustment remote commander (New LANC Jig)as follows. Changing the page

    The page increases when the Page+ ( M ) button is pressed,

    and decreases when the Page (m ) button is pressed. Changing the address

    The address increases when the ADD+ ( N ) button is pressed,and decreases when the ADD (X ) button is pressed. Thereare altogether 256 addresses, from 00 to FF.

    Changing the data (Data setting)The data increases when the Data+ button is pressed, anddecreases when the Data button is pressed. There are alto-gether 256 data, from 00 to FF.

    Writing the adjustment dataThe Write ( x ) button must be pressed to write the adjust-ment data in the nonvolatile memory. (The new adjustingdata will not be recorded in the nonvolatile memory if thisstep is not performed)

    4) After completing all adjustments, turn off the main power sup-ply (8.4 V) once.

    2. Precautions Upon Using the Adjustment RemoteCommander (New LANC Jig)

    Mishandling of the adjustment remote commander (New LANCJig) may erase the correct adjustment data at times. To preventthis, it is recommended that all adjustment data be noted downbefore beginning adjustments and new adjustment data after eachadjustment.

    Page Address Data

    p:00 a:00 d:00

  • 8/10/2019 GV-HD700 6 SM ver1.0

    28/386-27GV-HD700/HD700E_ADJ

    4-3. APPLICATION FOR ADJUSTMENT(SeusCam)

    The adjustment software (SeusCam) can change operational coef-ficients of signal processing, EVR data, etc. same as the adjust-ment remote commander. The SeusCam performs two-way com-.

    munication between PC and camcoder using the USB terminal.The two-way communication result data can be written in the non-volatile memory..Note 1: The SeusCam is used exclusively for the camcoders

    (DCR, DHR, CCD, etc.). It cannot be used for digitalcameras (DSC, MVC, etc.).

    Note 2: Before using the SeusCam, set the following data usingthe adjustment remote commander. .1) Select page: 0, address: 01, and set data: 01.2) Select page: A, address: 15, set data: 01, and press

    the PAUSE button.

    After use, release the set data.1) Select page: 0, address: 01, and set data: 01.

    2) Select page: A, address: 15, set data: 00, and pressthe PAUSE button.

    3) Select page: 0, address: 01, and set data: 00.

    1. Connection1) Connect the HASP key to the USB terminal of the PC.2) Connect the PC and camcoder with the USB cable.3) Start the SeusCam on the PC.4) Click [Connect] on the SeusCam screen. If the connection is

    normal, the SeusCam screen will be as shown in Fig. 6-4-3,indicating the "connected" state.Note: The SeusCam will go in "disconnect" state, if the set is

    turned off (for instance, by resetting the set). In such acase, click

    [Connect] on the SeusCam screen to re-store the "connected" state.

    2. OperationPage changeTo change the page, click [Page] on the SeusCam screen andenter the page to be changed. The page is displayed in hexa-decimal notation.

    Address changeTo change the address, click [Address] on the SeusCam screenand enter the address to be changed. The address is displayed inhexadecimal notation.

    Data changeTo change the data, click [Set] on the SeusCam screen and en-ter the data. The data is displayed in hexadecimal notation.This operation does not write the data to the nonvolatile memory.

    Data writingTo write the data to the nonvolatile memory, click [Write] onthe SeusCam screen and enter the data to be written.

    Data readingThe data displayed on the SeusCam screen are the data valuesat the time when the pages and addresses were set, and they areenot updated automatically, To check the data change, click [Read] on the SeusCam screen and update the displayed data.

    3. Difference in Display Between SeusCam andAdjustment Remote Commander

    There is no difference in display of address and data betweenSeusCam and adjustment remote commander. Though the page isdisplayed in one digit on the adjustment remote commander, it isdisplayed in two digits on the SeusCam.The "page 1A" or "page 1F" is selected after setting data: 01 tothe page: 0, address: 10 on the adjustment remote commander,

    while it can be selected by clicking the [Page] and entering "1A"or "1F" on the SeusCam. For the "page A " or "page F", enter "0A"or "0F".

    4. Precaution on Use of SeusCamWrong SeusCam operation could clear correct adjustment data.To prevent the data clear by mistake, it is recommended to save alladjustment data by clicking [Page Edit] on the SeusCam screenbefore starting the adjustment.

    Saving Method:1) Click [Page Edit] on the SeusCam screen to display the SeusCam

    Page Edit screen.2) Click [Page] , and enter the page number to be saved.3) Click [Read] to read the data to be saved from the set.4) Click [File] and save the data to PC.

    Loading Method:1) Select page: 00, address: 01 and set data: 01.2) Click [Page Edit] on the SeusCam screen to display the SeusCam

    Page Edit screen.3) Click [File] and load the data from PC.4) Click [Write] on the SeusCam Page Edit screen.Fig. 6-4-3

  • 8/10/2019 GV-HD700 6 SM ver1.0

    29/386-28GV-HD700/HD700E_ADJ

    Hexadecimal-decimal Conversion TableLower digit ofhexadecimal

    Upper digitof hexadecimal

    0 1 2 3 4 5 6 7 8 9 A(A)

    B(b )

    C(c )

    D(d )

    E(E )

    F(F )

    0123

    456

    789A (A )

    B (b )C ( c )D (d )

    E ( E )F (F )

    0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

    16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

    32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47

    48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63

    64 65 66 67 68 69 70 71 72 73 74 77 76 77 78 79

    80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95

    96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111

    112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

    128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143

    144 145 146 147 148 149 150 151 152 153 154 155 156 157 158

    174

    159

    175160 161 162 163 164 165 166 167 168 169 170 171 172 173

    177176 178 179 180 181 182 183 184 185 186 187 188 189 190 191

    192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207

    208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223

    224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239

    240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255

    0

    1

    Note: The characters shown in the parenthesis ( ) shown the display on the adjustment remote commander.(Example) If the DDS display or the adjustment remote commander shows BD ( bd );

    Because the upper digit of the adjustment number is B ( b ), and the lower digit is D ( d ), the meeting point189 of 1 and 2 in the above table is the corresponding decimal number.

    0

    2

    4-4 . DATA PROCESSThe calculation of the DDS display and the adjustment remotecommander display data (hexadecimal notation) are required forobtaining the adjustment data of some adjustment items. In thiscase, after converting the hexadecimal notation to decimal nota-tion, calculate and convert the result to hexadecimal notation, anduse it as the adjustment data. Indicates the hexadecimal-decimalconversion table.

    Table 6-4-1

  • 8/10/2019 GV-HD700 6 SM ver1.0

    30/386-29GV-HD700/HD700E_ADJ

    4-5 . SERVICE MODE

    Note: Before performing the adjustment, check the data of page:0, address: 10 is 00. If not, select page: 0, address: 00,and set data 00.

    1. Setting the Test Mode

    Page A Address 10

    Data Function

    00 Normal

    02 Forced VTR power ON

    Before setting the data , select page: 0, address: 01, and set data:01.

    For page A, the data set will be recorded in the non-volatilememory by pressing the PAUSE (Write) button of the adjust-ment remote commander. In this case, take note that the test

    mode will not be exited even when the main power is turned off (8.4 Vdc).

    After completing adjustments/repairs, be sure to return the dataof this address to 00, and press the PAUSE (Write) button of theadjustment remote commander. And select page: 0, address: 01,and set data: 00.

    2. Emergence Memory Address2-1. Emergence Memory Address (Mechanism

    section)

    Page C Address F4 to FF

    Address Contents

    F4 EMG code when first error occurs

    F6Upper: MSW code when shift starts when first error

    occursLower: MSW code when first error occurs

    F7 Lower: MSW code to be moved when first erroroccurs

    F8 EMG code when second error occurs

    FAUpper: MSW code when shift starts when second

    error occursLower: MSW code when second error occurs

    FB Lower: MSW code to be moved when second error

    occursFC EMG code when last error occurs

    FEUpper: MSW code when shift starts when last error

    occursLower: MSW code when last error occurs

    FF Lower: MSW code to be moved when last erroroccurs

    When no error occurs in this unit, data 00 is written in the aboveaddresses (F4 to FF). when first error occurs in the unit, the datacorresponding to the error is written in the first emergency ad-dress (F4 to F7). In the same way, when the second error occurs,the data corresponding to the error is written in the second emer-gency address (F8 to FB).Finally, when the last error occurs, the data corresponding to theerror is written in the last emergency address (FC to FF).Note: After completing adjustments, be sure to initialize the data

    of addresses F4 to FF to 00.

    Initializing method:

    Order Page Address Data Procedure

    1 0 01 01

    2 3 03 FF

    3 3 01 37 Press PAUSE (Write) button.

    4 3 02 Check the data changes to00.

    5 3 03 Check the data changes to00.

    6 0 01 01

  • 8/10/2019 GV-HD700 6 SM ver1.0

    31/386-30GV-HD700/HD700E_ADJ

    0

    0

    1

    0

    =

    2

    0

    1

    1

    1

    =

    7

    UNLOAD

    Lock releasedCassette compartment

    Pinch roller pressing

    LS chassis movement section

    EJ BL

    0

    0

    1

    1

    =

    3

    0

    1

    1

    1

    =

    7

    ULE BL

    0

    0

    0

    1

    =

    1

    0

    1

    1

    1

    =

    7

    LD1 (SR) LD2 (HL)BL

    0

    1

    0

    1

    =

    5

    0

    1

    1

    1

    =

    7

    BL

    0

    1

    0

    0

    =

    4

    0

    1

    1

    1

    =

    7

    STOP BL

    0

    1

    1

    0

    =

    6

    R/P

    LOAD

    D (MSB) C

    B A (LSB)

    Mechanical Position

    2-3. MSW CodeMSW when errors occur:Information on MSW (mode SW) when errors occurMSW when movement starts:Information on MSW when movements starts when the mechanism position is moved (When the L motor is moved)MSW of target of movement:Information on target MSW of movement when the mechanism position is moved

    2-2. EMG Code (Emergency Code)Codes corresponding to the errors which occur are written in Cpage, addresses F4, F8 and FC . The type of error indicated by thecode are shown in the following table.

    Code Emergency Type

    00 No error

    10 Loading motor emergency during loading

    11 Loading motor emergency during unloading

    22 T reel emergency during normal rotation

    23 S reel emergency during normal rotation

    24 T reel emergency (Short circuit between S reelterminal and T reel terminal)

    30 FG emergency at the start up of the capstan

    40 FG emergency at the start up of the drum

    42 FG emergency during normal rotation of the drum

    Position

    EJ

    BL

    ULE

    LD1 (SR)

    LD2 (HL)

    STOP

    R/P

    NULL

    Code

    2

    7

    3

    1

    5

    4

    6

    0F

    Contents

    Position at which the cassette component lock is released, at the farthest unload side mechanicallyat which the mechanism can move no further in the UNLOAD direction.BLANK code, at the boundary between codes.EJECT completion position. when the cassette is ejected, the mechanism will stop at this position.Cassette IN standby. The guide will start protruding out as the mechanism moves towards theLOAD position.When prepraing TOP load processing or when DEW is detected, rolling up tape by T reel ispreformed at this position.When prepraing TOP load processing or when DEW is detected, rolling up tape by S reel ispreformed at this position.Stop position in the loading state. The pinch roller separates, the tension regulator returns, and thebrake is imposed on both reels.PB, REC, CUE, REVIEW, PAUSE, FF, REW positions. When pinch roller is pressed, and thetension regulator is ON, the mechanism is operating at this position in modes in which normalimages are shown.Code not existing in the MD. Default value.Status before finding any mechanism position.

  • 8/10/2019 GV-HD700 6 SM ver1.0

    32/386-31GV-HD700/HD700E_ADJ

    3. Bit Value DiscriminationBit values must be discriminated using the display data of the ad-

    justment remote commander for the following items. Use the tablebelow to discriminate if the bit value is 1 or 0.

    (Example) If the remote commander display is 8E, bit value frombit 7 to bit 4 can be discriminated from the column A ,and those from bit 3 to bit 0 from column B .

    PageAddress

    bit3 to bit0 discrimination

    bit7 to bit4 discrimination

    Display on the adjustment remote commander

    Display on theadjustment

    remotecommander

    01

    23456789

    A ( A )B (b )C ( C )D (d )E (E )F (F )

    Bit valuesbit3or

    bit700

    00000011111111

    bit2or

    bit600

    00111100001111

    bit1or

    bit500

    11001100110011

    bit0or

    bit401

    01010101010101

    A

    B

    4. Jack Check (1)

    Page 2 Address 73

    Using method:1) Select page: 2, address: 73.

    2) By discriminating the bit value of display data, the state of jack can be discriminated.

    5. Jack Check (2)

    Page 7 Address FB

    Using method:1) Select page: 7, address: FB.2) By discriminating the bit value of display data, the state of jack can be discriminated.

    6. Jack Check (3)

    Page 7 Address FF

    Using method:1) Select page: 7, address: FF.2) By discriminating the bit value of display data, the state of jack can be discriminated.

    Bit Function When bit value = 0 When bit value = 1

    0 DC IN jack (FP-705 board J101) Used Not used

    Bit Function When bit value = 1 When bit value = 0

    0 A/V OUT jack (JK-345 board CN502) Used Not used

    Bit Function When bit value = 1 When bit value = 0

    1 COMPONENT OUT jack (JK-345 board CN503) Used Not used

  • 8/10/2019 GV-HD700 6 SM ver1.0

    33/386-32GV-HD700/HD700E_ADJ

    7. Jack Check (4)

    Page 3 Address CF

    Bit Function When bit value = 1 When bit value = 0

    0 HDMI OUT jack (JK-345 board CN401) Used Not used

    Using method:1) Select page: 3, address: CF.2) By discriminating the bit value of display data, the state of jack can be discriminated.

    8. Jack Check (5)

    Page 3 Address 61

    Bit Function When bit value = 1 When bit value = 0

    6 PHONES jack (HP-151 board J901) Used Not used

    Using method:1) Select page: 3, address: 61.2) By discriminating the bit value of display data, the state of jack can be discriminated.

    9. Jack Check (6)

    Page 3 Address CF

    Bit Function When bit value = 1 When bit value = 0

    2 S VIDEO IN jack (JK-346 board J701) Used Not used

    Using method:1) Select page: 7, address: FB.2) By discriminating the bit value of display data, the state of jack can be discriminated.

    10. Jack Check (7)

    Page 7 Address FB

    Bit Function When bit value = 1 When bit value = 06 HDV/DV i. Link jack (JK-345 board CN501) Used Not used

    Useing method:1) Select page: 7, address: FB2) By discriminating the bit valu of display data, the state of jack can be discriminated.

    11. Switch Check (1)Page 2 Address 81

    Bit Function When bit value = 1 When bit value = 0

    0 POWER (FK-093 board S830) ON OFF

    3 EJECT (FP-706 flexible board S151) ON OFF

    4 CC DOWN (Mechanism chassis) ON (DOWN) OFF (UP)

    5 DISPLAY/BATT INFO (FK-093 board S829) ON OFF

    Using method:1) Select page: 2, address: 81.

    2) By discriminating the bit value of display data, the state of switch can be discriminated.

  • 8/10/2019 GV-HD700 6 SM ver1.0

    34/386-33GV-HD700/HD700E_ADJ

    12. Switch Check (2)

    Page 7 Address 65 to 6B

    Note: Check that the data of page: 0, address: 10 is 00.

    Using method:1) Select page: 7, address: 65 to 6B.2) By discriminating the display data, the pressed key can be discriminated.

    Address

    65(KEY AD0)

    (IC4003 )

    66(KEY AD1)

    (IC4003 )

    67(KEY AD2)

    (IC4003 )

    68(KEY AD3)

    (IC4003 )

    69(KEY AD4)

    (IC4003 )

    6A(KEY AD5)

    (IC4003 )

    6B(KEY AD6)

    (IC4003 )

    00 to 0C

    STOP(FK-093)(S824)

    PAUSE(FK-093)(S826)

    UP(FK-093)(S813)

    DOWN(FK-093)(S807)

    RIGHT(FK-093)(S804)

    LEFT(FK-093)(S802)

    EXEC(FK-093)(S819)

    STATUSCHECK(FK-093)(S814)

    VOLUME+

    (FK-093)(S827)

    ASSIGN1(FK-093)(S828)

    ASSIGN2(FK-093)(S822)

    MEMORYPLAY

    (FK-093)(S817)

    MEMORYINDEX(FK-093)(S810)

    MEMORYDELETE(FK-093)(S805)

    ASSIGN3(FK-093)(S816)

    VOLUME-

    (FK-093)(S821)

    LCD BRIGHT

    +(FK-093)(S815)

    LCD BRIGHT

    -(FK-093)(S809)

    LCDON/OFF(FK-093)(S808)

    MENU(FK-093)(S820)

    ALL SCAN(FK-093)(S823)

    MEMORYPHOTO(FK-093)(S825)

    LCDOPEN(FP-714)(S651)

    LCDCLOSE(FP-714)(S651)

    0D to 27

    REW(FK-093)(S818)

    32 to 3A

    REC(FK-093)

    (S811, 812)

    4F to 58

    PLAY(FK-093)(S806)

    73 to 7B

    FF(FK-093)(S803)

    8B to B7

    SLOW(FK-093)(S801)

    B8 to E6

    E7 to FF

    Data

    139

    140

    141

    142

    143

    144

    145

  • 8/10/2019 GV-HD700 6 SM ver1.0

    35/386-34GV-HD700/HD700E_ADJ

    13. LED Check

    Page 7 Address 00, 01, 02 and 04

    Note: Check that the data of page: 0, address: 10 is 00.

    Using method:

    Order Page Address Data Procedure

    1 7 01 90

    2 7 02 FF

    3 7 04 01

    4 7 00 01 Press PAUSE (Write) button.

    5 7 02 Check the data changes to01.

    6

    Check that the followingLED are lit. POWER MS ACCESS

    7 7 01 908 7 02 FF

    9 7 04 00

    10 7 00 01 Press PAUSE (Write) button.

    11 7 02 Check the data changes to01.

    14. Record of Use Check (1)

    Page 7 Address A4 to AF

    Note 1: This data will not be erased (reset) when the lithium 3 Vpower supply (RR-003 board BT9601) is removed.

    Note 2: When the drum was replaced, initialize the drum rota-tion counted time.

    Note 3: Check that the data of page: 0, address: 10 is 00.

    Using method:1) The record of use data is displayed at page: 7, addresses: A4 to

    AF.

    Address

    A4

    A5

    A6

    A7

    A8

    A9

    AA

    AB

    AC

    AD

    AE

    AF

    Function

    Power supplying Hour (H)

    time Hour (M)

    Hour (L)

    (BCD code) Minute

    Drum rotation Hour (H)

    counted time Hour (M)

    Hour (L)

    (BCD code) Minute

    Tape run time Hour (H)

    Hour (M)

    Hour (L)

    (BCD code) Minute

    Remarks

    100000th p lace digit and 10000th place digit of counted time (decimal digit)

    1000th place digit and 100th place digit of counted time (decimal digit)

    10th place digit and 1st place digit of counted time (decimal digit)

    100000th p lace digit and 10000th place digit of counted time (decimal digit)

    1000th place digit and 100th place digit of counted time (decimal digit)

    10th place digit and 1st place digit of counted time (decimal digit)

    100000th p lace digit and 10000th place digit of counted time (decimal digit)

    1000th place digit and 100th place digit of counted time (decimal digit)

    10th place digit and 1st place digit of counted time (decimal digit)

  • 8/10/2019 GV-HD700 6 SM ver1.0

    36/386-35GV-HD700/HD700E_ADJ

    15. Record of Use Check (2)

    Page 7 Address 90 to 95

    Note 1: This data will not be erased (reset) when the lithium 3 Vpower supply (RR-003 board BT9601) is removed.

    Note 2: When the drum was replaced, initialize the drum rota-tion counted time.

    Note 3: Check that the data of page: 0, address: 10 is 00.

    Using method:1) The record of use data is displayed at page: 7, addresses: 90 to

    95.

    Initializing method:

    Order Page Address Data Procedure

    1 7 90 00 Press PAUSE (Write) button.

    2 7 91 00 Press PAUSE (Write) button.3 7 92 00 Press PAUSE (Write) button.

    4 7 93 00 Press PAUSE (Write) button.

    5 7 94 00 Press PAUSE (Write) button.

    6 7 95 00 Press PAUSE (Write) button.

    Address

    90

    91

    9293

    94

    95

    Initializing method:

    Order Page Address Data Procedure

    1 7 A4 00 Press PAUSE (Write) button.

    2 7 A5 00 Press PAUSE (Write) button.

    3 7 A6 00 Press PAUSE (Write) button.

    4 7 A7 00 Press PAUSE (Write) button.5 7 A8 00 Press PAUSE (Write) button.

    6 7 A9 00 Press PAUSE (Write) button.

    7 7 AA 00 Press PAUSE (Write) button.

    8 7 AB 00 Press PAUSE (Write) button.

    9 7 AC 00 Press PAUSE (Write) button.

    10 7 AD 00 Press PAUSE (Write) button.

    11 7 AE 00 Press PAUSE (Write) button.

    12 7 AF 00 Press PAUSE (Write) button.

    Function

    Eject count with tape Count (H)

    Count (M)

    (BCD code) Count (L)

    Eject count without Count (H)

    tape Count (M)

    (BCD code) Count (L)

    Remarks

    100000th place digit and 10000th place digit ofEject count (decimal digit)

    1000th place digit and 100th place digit of Eject count (decimal digit)

    10th place digit and 1st place digit of Eject count (decimal digit)

    100000th place digit and 10000th place digit of Eject count (decimal digit)

    1000th place digit and 100th place digit of Eject count (decimal digit)

    10th place digit and 1st place digit of Eject count (decimal digit)

  • 8/10/2019 GV-HD700 6 SM ver1.0

    37/386-36GV-HD700/HD700E_ADJ

    16. Record of Use Check (3)

    Page 7 Address C8 to CD

    Note 1: This data will not be erased (reset) when the lithium 3 Vpower supply (RR-003 board BT9601) is removed.

    Note 2: Check that the data of page: 0, address 10 is 00.

    Using method:1) The record of use data is displayed at page: 7, addresses: C8 to

    CD.

    17. Record of Self-diagnosis Check

    Page 7 Address B0 to C6

    Note 1: This data will not be erased (reset) when the lithium 3 Vpower supply (RR-003 board BT9601) is removed.

    Note 2: Check that the data of page: 0, address 10 is 00.

    *1 : 01 t C, 03 t E

    Using method:1) The past self-diagnosis codes are displayed at page: 7, address:

    BC to C6. Refer to 1-5. SELF-DIAGNOSIS FUNCTION of SERVICE MANUAL, LEVEL 2 for detail of the self-diag-nosis code.

    Address

    C8

    C9

    CA

    CB

    CC

    CD

    Function

    User initial power Year

    on date Month

    (BCD code) Day

    Final condensation Year

    occurrence date Month

    (BCD code) Day

    Remarks

    After setting the clock, set the date of power on next

    Address

    B0

    B1

    B2

    B4

    B5

    B6

    B8

    B9

    BA

    BC

    BD

    BE

    C0

    C1

    C2

    C4

    C5

    C6

    Self-diagnosis code

    Repaired by code (Occurred 1st time) *1

    Block function code (Occurred 1st time)

    Detailed code (Occurred 1st time)

    Repaired by code (Occurred 2nd time) *1

    Block function code (Occurred 2nd time)

    Detailed code (Occurred 2nd time)

    Repaired by code (Occurred 3rd time) *1

    Block function code (Occurred 3rd time)

    Detailed code (Occurred 3rd time)

    Repaired by code (Occurred 4th time) *1

    Block function code (Occurred 4th time)

    Detailed code (Occurred 4th time)

    Repaired by code (Occurred 5th time) *1

    Block function code (Occurred 5th time)

    Detailed code (Occurred 5th time)

    Repaired by code (Occurred the last time) *1

    Block function code (Occurred the last time)

    Detailed code (Occurred the last time)

    Initializing method:

    Order Page Address Data Procedure

    1 7 01 C0

    2 7 00 01 Press PAUSE button.

    3 7 B0 to C6 Check that the data is 00.

    4 7 00 00

    5 7 01 00

  • 8/10/2019 GV-HD700 6 SM ver1.0

    38/38

    Revision History

    Reverse

    Ver.

    1.0

    Date

    2007.08

    History

    Official Release

    Contents

    S.M. Rev.issued

    985221851.pdf