 Guidance   Handling Modules & Cables BS-240 / 240 II / 240 XL / 240XL II 3 th  March 2015

Upload: andik-manchesterunited

Post on 02-Nov-2015

228 views

Category:

Documents


1 download

DESCRIPTION

SEX

TRANSCRIPT

  • Guidance Handling Modules & Cables BS-240 / 240 II / 240 XL / 240XL II

    3th March 2015

  • General Overview

  • Detail BS24X Series

  • Semirigid

    A minimum bending radius of 10 mm (semi-rigid TX) and 3,5 mm (semi-rigid RX) must be

    ensured. Fix the system cables at SMA connectors with a torque wrench set to 1,00 Nm and

    at SMC connectors with a torque wrench set to 0,35 Nm. Terminate all unused connectors

    of the antenna combiners with 50 Ohm load resistors!

  • Flexi Cabling

    Fix the system cables at SMA connectors with a torque wrench set to 1,00 Nm and at SMC connectors with a torque

    wrench set to 0,35 Nm. Terminate all unused connectors of the antenna combiners with 50 Ohm load resistors!

    The cables have to be routed in such a way that allows the ease exchange of modules (CUs, Combiners and FANs). For

    this reason BTS Base-/Extension cabinets which have been equipped with flexible HF cabling in the factory always, come

    with a pair of cableretainers fitted left-and right hand side at the bottom of each sub-rack (exception: lowest subrack of a

    cabinet). Route the cables, so that the LED-indications of the modules are visible and the test adapter connectors are

    accessible. The task of these cable retainers - which are bended sheet metal parts - is to keep those flexible HF-cables in

    a neat position which inter-connect subracks. If a customer decides to retrofit an 1th generation base station - which has

    not been equipped with cable-retainers -with flexible HF cables, these cables must be loosely fitted with cable-ties

  • Flexi Cable - Partcode

    6

    Choose the type

    According to BTS Type

  • Fitting Indoor Jumper Cable & Connector

    7

  • Unscrew the Module / Part

    Handling with care , Material used from Plastic, for COBA/FAN

  • MFDUAMCO + HYBRID4

    9

  • FCU / COBA

    10

  • FDUAMCO

    11

  • COAMCO

    12

  • OP Ext Alarm

    13

  • SELIC Cabling Location

    Selic Cable & CAN BUS Position

  • Fan