guaranteed roofing solutions - radmat · [email protected] working kings cross gas holder triplets...

6
GUARANTEED ROOFING SOLUTIONS

Upload: others

Post on 23-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GUARANTEED ROOFING SOLUTIONS - Radmat · Quantum@radmat.com Working Kings Cross Gas Holder Triplets Walkway NF 1:100@A3 05/09/17 Q170585-L01-01 Rev03 Information 1. Do not scale from

GUARANTEED ROOFING SOLUTIONS

Page 2: GUARANTEED ROOFING SOLUTIONS - Radmat · Quantum@radmat.com Working Kings Cross Gas Holder Triplets Walkway NF 1:100@A3 05/09/17 Q170585-L01-01 Rev03 Information 1. Do not scale from

What is Quantum®?

16/5347

Page 3: GUARANTEED ROOFING SOLUTIONS - Radmat · Quantum@radmat.com Working Kings Cross Gas Holder Triplets Walkway NF 1:100@A3 05/09/17 Q170585-L01-01 Rev03 Information 1. Do not scale from

Lose height, gain value

Scan the code or visit the Quantum® website at:

prothermquantum.com

Page 4: GUARANTEED ROOFING SOLUTIONS - Radmat · Quantum@radmat.com Working Kings Cross Gas Holder Triplets Walkway NF 1:100@A3 05/09/17 Q170585-L01-01 Rev03 Information 1. Do not scale from

The Anatomy of Quantum®

Page 5: GUARANTEED ROOFING SOLUTIONS - Radmat · Quantum@radmat.com Working Kings Cross Gas Holder Triplets Walkway NF 1:100@A3 05/09/17 Q170585-L01-01 Rev03 Information 1. Do not scale from

Quantum® Performance

RWO

RWO

RWO

GG

E

GE G

GE

GGE

GG

E

GG

E

GE

GGE

GGG

GGG

GE

GG

G

EG

G

EG

EG

GG

GG

GG

G

G G

G EG

G EG

EG

G EG

G G

G G

EGG

EGG

EG

G

EG

EGG

EGG

EGG

EGGG

EG

G

EG

G

EG

EG

G

EG

G

EG

G

EG

EG

G

EG

GE

G

GE

G

GG

GGG

GE G

GE G

E G

GE G

GE G

GG

E G

GE G

GE G

GE G

EG

G

EG

B

C

B

B

C D

B

C

B

C DB B

BB

B

B

B

B

B

B

B

B

B

B

BBB

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

BBB

B

CD

F

F

F

F

F

CD

CD

CD

CD

CCD

CD

CD

CD

CD

CD

C D

G

G

B

B

B B B

B

B

B

B

B

C

B

B

BB

B

B

B

B

BB B

THIS CAD DRAWING (electronic or paper format) AND THE COPYRIGHT THEREON ARETHE PROPERTY OF RADMAT BUILDING PRODUCTS AND MUST NOT BE REPRODUCED

IN PART OR IN WHOLE OR PASSED ON TO OTHERS WITHOUT PERMISSION

Tel: (01858) 410 372Fax: (01858) 410 572

[email protected]

Working

Kings Cross Gas Holder TripletsWalkway

NF 1:100@A305/09/17

Q170585-L01-01 Rev03

Information

1. Do not scale from this drawing2. Contractor to be responsible for checking all details against architects drawings/site requirements.

Advise Radmat Building Products immediately of any discrepancies.3. The drawing includes sufficient material to complete the scheme any additional material requested will

be charged at the going rate, and may incur additional transport surcharges.4. The scheme does not account for insulation to upstands unless otherwise stated.5. A suitable finished roof deck without substantial depression is assumed, unless otherwise stated.

If backfalls or depressions are present further advice should be sought.6. Setting out from edges indicated , if shown.7. Flex infills are cut from whole boards on site by the contractor. Quantum boards are NOT to be cut.8. Orders placed against this drawing reference/revision number assume approval of the scheme.

DatumSection Point

20mm ProTherm G to be overlaid over whole roof,including pitch pockets.

Total Roof Area: 153.7m²U-value achieved: 0.2W/m²K

55mm ProTherm Quantum PURE(+5mm Regupol beneath Quantum)

60mm ProTherm Flex Infill

RWO

RWO

RWO

THIS CAD DRAWING (electronic or paper format) AND THE COPYRIGHT THEREON ARETHE PROPERTY OF RADMAT BUILDING PRODUCTS AND MUST NOT BE REPRODUCED

IN PART OR IN WHOLE OR PASSED ON TO OTHERS WITHOUT PERMISSION

Tel: (01858) 410 372Fax: (01858) 410 572

[email protected]

Outline

Kings Cross Gas Holder TripletsWalkway

NF 1:100@A305/09/17

Q170585-L01 Revision 03

Information

1. Do not scale from this drawing2. Contractor to be responsible for checking all details against architects drawings/site requirements.

Advise Radmat Building Products immediately of any discrepancies.3. The drawing includes sufficient material to complete the scheme any additional material requested will

be charged at the going rate, and may incur additional transport surcharges.4. The scheme does not account for insulation to upstands unless otherwise stated.5. A suitable finished roof deck without substantial depression is assumed, unless otherwise stated.

If backfalls or depressions are present further advice should be sought.6. Setting out from edges indicated , if shown.7. Flex infills are cut from whole boards on site by the contractor. Quantum boards are NOT to be cut.8. Orders placed against this drawing reference/revision number assume approval of the scheme.

DatumSection Point

52mm ProTherm Quantum PLUS

50mm ProTherm Flex Infill

20mm ProTherm G to be overlaid over whole roof,including pitch pockets.

Total Roof Area: 153.7m²U-value achieved: 0.2W/m²K

55mm ProTherm Quantum PURE(+5mm Regupol beneath Quantum)

60mm ProTherm Flex Infill

Quantum System thickness 85mm*

Area weighted ‘U’ value (W/m2K)

* 5mm Regupol, 75mm Quantum, 5mm Regupol with 250mm concrete deck, ceiling void and plasterboard ceiling.

0.12 0.14 0.15 0.16

ProTherm Quantum System‚ U‚ values based on 15% Flex installed over 250mm concrete deck, ceiling void and plasterboard ceiling.

1 2 3 4 5 6 7

U-value W/m2K

SSL-FFL(mm)

System Height (mm)

XPS(mm)

Quantum®

(mm)Regupol

RCM (mm)Waterproofing

(mm)

0.20 190 115 80 20 5 10

0.15 250 175 140 20 5 10

0.14 190 115 50 50 5 10

0.13 190 115 30 70 5 10

0.13 250 175 120 40 5 10

0.11 250 175 100 60 5 10

0.09 250 175 80 80 5 10

0.08 250 175 50 110 5 10

0.23 135 60 5 40 5 10

0.21 140 65 5 45 5 10

0.18 150 75 5 55 5 10

Page 6: GUARANTEED ROOFING SOLUTIONS - Radmat · Quantum@radmat.com Working Kings Cross Gas Holder Triplets Walkway NF 1:100@A3 05/09/17 Q170585-L01-01 Rev03 Information 1. Do not scale from

26/03/2018