GTP” General Treatment GTP” General Treatment Products Products Glycol Feed Packages Glycol Feed Packages Introduction, Sizes, Models, Wiring and Introduction, Sizes, Models, Wiring and Trouble Shooting Trouble Shooting Spring 2006 Spring 2006 “GR-E” Residential “GP-E” Industrial Wiring Trouble Shooting Contact Us Introduction “GX” Wall Mount

Upload: agustin-addy

Post on 29-Mar-2015

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

““GTP” General Treatment GTP” General Treatment ProductsProducts

Glycol Feed PackagesGlycol Feed PackagesIntroduction, Sizes, Models, Wiring and Trouble Introduction, Sizes, Models, Wiring and Trouble

ShootingShooting

Spring 2006Spring 2006

“GR-E” Residential

“GP-E” Industrial

Wiring

Trouble Shooting

Contact Us

Introduction

“GX” Wall Mount

Page 2: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GTP” IntroductionGTP” Introduction

GTP is your new source for:GTP is your new source for: Glycol Feed SystemsGlycol Feed Systems Poly and Steel TanksPoly and Steel Tanks Tank StandsTank Stands High Speed MixersHigh Speed Mixers

and Custom Systems.and Custom Systems.

GTPGTP now offers a complete line of: Glycol Feed Systems ranging from: 7.5 now offers a complete line of: Glycol Feed Systems ranging from: 7.5 Gallon, 15 Gallon, 30 Gallon, 50 Gallon and 100 GallonGallon, 15 Gallon, 30 Gallon, 50 Gallon and 100 Gallon

Poly and Steel Tanks and Tank Stands ranging from: 5 to 500 GallonPoly and Steel Tanks and Tank Stands ranging from: 5 to 500 GallonHigh Speed Mixers - Bracket, Flanged, Clamp, Thread and Tank Mounts ranging High Speed Mixers - Bracket, Flanged, Clamp, Thread and Tank Mounts ranging

from: 1/50HP to 1HP. from: 1/50HP to 1HP. And a complete package of accessories/options available for each product.And a complete package of accessories/options available for each product.With a combined 27 years of industry experience and for a quality product at a With a combined 27 years of industry experience and for a quality product at a

great price, let great price, let GTPGTP be your new source of H.V.A.C. treatment equipment. be your new source of H.V.A.C. treatment equipment.

Coming soon:Coming soon: A complete line of Bypass/Filter FeedersA complete line of Bypass/Filter Feeders

Page 3: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GR-E” Residential PackagesGR-E” Residential Packages

FeaturesFeatures 7.5 & 15 Gallon sizes7.5 & 15 Gallon sizes Industrial Poly Tank and Industrial Poly Tank and

Hinged CoverHinged Cover 0.5GPH Metering Pump0.5GPH Metering Pump Pressure Switch, Check Valve, Pressure Switch, Check Valve,

Pressure Relief Valve and Pressure Relief Valve and Isolation ValveIsolation Valve

Surge ChamberSurge Chamber Customer Defined SettingsCustomer Defined Settings 2 Year Factory Warranty2 Year Factory Warranty

Page 4: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GR-E” Residential PackagesGR-E” Residential Packages

OptionsOptions Pump Outputs:Pump Outputs:

1.0GPH Metering Pump or1.0GPH Metering Pump or

6.4GPH Metering Pump6.4GPH Metering Pump Audible Alarm & Silence Audible Alarm & Silence

SwitchSwitch Dry Contact on Low LevelDry Contact on Low Level High Level AlarmHigh Level Alarm Mixer and Control SwitchMixer and Control Switch Pressure RangesPressure Ranges Wall Mounting BracketWall Mounting Bracket

Page 5: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GR-E” Model NumbersGR-E” Model Numbers

Model Number: GR07-E1-3/HM-AL

GR = Base model

Residential glycol feed package, tank, hinged lid, control box, 0.5 GPH metering pump, pressure switch, low level switch and indicator, suction and discharge manifold.

Page 6: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GR-E” Model NumbersGR-E” Model Numbers

07 = Tank size

GR = Base model

Tank size in gallons. Residential packages can be ordered in 7.5 gallon (“07”) and 15 gallon (“15”) tank sizes.

Model Number: GR07-E1-3/HM-AL

Page 7: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GR-E” Model NumbersGR-E” Model Numbers

GR = Base model

07 = Tank size

-E1 = Standard package

“-E1” is the base package which includes standard pump, control panel and manifolds.

Model Number: GR07-E1-3/HM-AL

Page 8: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GR-E” Model NumbersGR-E” Model Numbers

GR = Base model

07 = Tank size

-E1 = Standard package

-3 = Pressure code

“-3” pressure code sets the pressure switch, pressure relief valve and pressure gauge. “-3” = 3-10 cut in, 9-30 cut out, 6-20 PSID. Optionally you can order “-1” = 10-45 cut in, 20-50 cut out, 10-30 PSID. “-2” = 40-80 cut in, 65-100 cut out, 20-40 PSID.

Model Number: GR07-E1-3/HM-AL

Page 9: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GR-E” Model NumbersGR-E” Model Numbers

GR = Base model

07 = Tank size

E1 = Standard package

-3 = Pressure code

/HM-AL = Optional features

“/HM-AL” Optional codes. This is where you would order optional features such as “HM” high temperature manifold and “AL” audible alarm and silence switch. (See pricing for details and additional options)

Model Number: GR07-E1-3/HM-AL

Page 10: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GP-E” Industrial PackagesGP-E” Industrial Packages

FeaturesFeatures 30, 55 & 100 Gallon sizes30, 55 & 100 Gallon sizes Industrial Poly Tank and 1/3 Industrial Poly Tank and 1/3

Hinged CoverHinged Cover Carbon Steel FrameCarbon Steel Frame Lockable Control PanelLockable Control Panel 1/3HP Gear Pump1/3HP Gear Pump Pressure Switch, Check Valve, Pressure Switch, Check Valve,

Pressure Relief Valve and Pressure Relief Valve and Isolation ValveIsolation Valve

2 Year Warranty2 Year Warranty

Page 11: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GP-E” Industrial PackagesGP-E” Industrial Packages

OptionsOptions 1/2HP Bronze Gear Pump1/2HP Bronze Gear Pump High Temperature ManifoldHigh Temperature Manifold Audible Alarm & Silence Audible Alarm & Silence

SwitchSwitch Dry Contact on Low LevelDry Contact on Low Level High Level AlarmHigh Level Alarm Mixer and Control SwitchMixer and Control Switch Surge ChamberSurge Chamber

Page 12: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GP-E” Model NumbersGP-E” Model Numbers

Model Number: GP55-E4-1/HM-AL

GP = Base model

Industrial glycol feed package, tank, hinged lid, tank stand, lockable control panel, 1/3HP open motor gear pump, pressure switch, low level switch and indicator, suction and discharge manifold.

Page 13: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GP-E” Model NumbersGP-E” Model Numbers

55 = Tank size

Tank size in gallons. Industrial packages can be ordered in 30 gallon (“30”), 55 gallon (“55”) and 100 gallon (“100) tank sizes.

GP = Base model

Model Number: GP55-E4-1/HM-AL

Page 14: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

E4 = Standard package, 1/3HP pump

“-E4” is the base package which includes standard pump, control panel and manifolds. “-H4” is a high temp package with steel tank, cover and manifolds. Adding a D before the package (“-DE4”) will indicate a dual pumps and dual manifolds.

GP = Base model

55 = Tank size

“ “GP-E” Model NumbersGP-E” Model Numbers

Model Number: GP55-E4-1/HM-AL

Page 15: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

-1 = Pressure code

“-1” pressure code sets the pressure switch, pressure relief valve and pressure gauge. 1 = 10-45 cut in, 20-50 cut out, 10-30 PSID. 2 = 40-80 cut in, 65-100 cut out, 20-40 PSID. 3 = 3-10 cut in, 9-30 cut out, 6-20 PSID.

GP = Base model

55 = Tank size

-E4 = Standard package, 1/3HP pump

“ “GP-E” Model NumbersGP-E” Model Numbers

Model Number: GP55-E4-1/HM-AL

Page 16: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

/HM-AL = Optional features

“/HM-AL” Optional codes. This is where you would order optional features such as “HM” high temperature manifold and “AL” audible alarm and silence switch. (See pricing for details and additional options)

GP = Base model

55 = Tank size

-E4 = Standard package, 1/3HP pump

-1 = Pressure code

“ “GP-E” Model NumbersGP-E” Model Numbers

Model Number: GP55-E4-1/HM-AL

Page 17: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

FeaturesFeatures Compact Freight Friendly Compact Freight Friendly

DesignDesign Carbon Steel FrameCarbon Steel Frame Lockable Control PanelLockable Control Panel 1/3HP Gear Pump1/3HP Gear Pump Pressure Switch, Check Valve, Pressure Switch, Check Valve,

Pressure Relief Valve and Pressure Relief Valve and Isolation ValveIsolation Valve

2 Year Warranty2 Year Warranty

“ “GX” Wall Mount Glycol FeedGX” Wall Mount Glycol Feed

Page 18: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

OptionsOptions 1/2HP Bronze Gear Pump1/2HP Bronze Gear Pump High Temperature ManifoldHigh Temperature Manifold Audible Alarm & Silence Audible Alarm & Silence

SwitchSwitch Dry Contact on Low LevelDry Contact on Low Level High Level AlarmHigh Level Alarm Surge ChamberSurge Chamber

“ “GX” Wall Mount Glycol FeedGX” Wall Mount Glycol Feed

Page 19: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GX” Wall Mount Glycol FeedGX” Wall Mount Glycol Feed

Model Number: GX-E4-1/HM-AL

GX = Base model

Wall mount “freight friendly” glycol feed package, wall mount bracket, lockable control panel, 1/3HP open motor gear pump, pressure switch, low level switch and indicator, suction and discharge manifold.

Page 20: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GX” Wall Mount Glycol FeedGX” Wall Mount Glycol Feed

Model Number: GX-E4-1/HM-AL

GX = Base model

E4 = Standard package, 1/3HP pump

“-E4” is the base package which includes standard pump, control panel and manifolds.

Page 21: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GX” Wall Mount Glycol FeedGX” Wall Mount Glycol Feed

Model Number: GX-E4-1/HM-AL

GX = Base model

E4 = Standard package, 1/3HP pump

-1 = Pressure code

“-1” pressure code sets the pressure switch, pressure relief valve and pressure gauge. 1 = 10-45 cut in, 20-50 cut out, 10-30 PSID. 2 = 40-80 cut in, 65-100 cut out, 20-40 PSID. 3 = 3-10 cut in, 9-30 cut out, 6-20 PSID.

Page 22: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

“ “GX” Wall Mount Glycol FeedGX” Wall Mount Glycol Feed

Model Number: GX-E4-1/HM-AL

GX = Base model

-1 = Pressure code

E4 = Standard package, 1/3HP pump

/HM-AL = Optional features

“/HM-AL” Optional codes. This is where you would order optional features such as “HM” high temperature manifold and “AL” audible alarm and silence switch. (See pricing for details and additional options)

Page 23: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

Wiring: StandardWiring: Standard

The diagram shown is for all systems based on

standard items.

Optional Dual Pumps

Optional Audible Alarm

Optional Dry Contact

Page 24: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

Wiring: Optional Dual PumpsWiring: Optional Dual Pumps

This diagram is for dual glycol systems.

Standard Wiring

Optional Audible Alarm

Optional Dry Contact

Page 25: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

Wiring: Optional Audible Wiring: Optional Audible AlarmAlarm

This diagram is for dual standard systems with

audible alarm.

Optional Dual Pumps

Standard Wiring

Optional Dry Contact

Page 26: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

Wiring: Optional Dry ContactWiring: Optional Dry Contact

This diagram is for dual standard system with dry

contact.

Optional Dual Pumps

Optional Audible Alarm

Standard Wiring

Page 27: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

Trouble ShootingTrouble ShootingPROBLEMPROBLEM POSSIBLE CAUSE OR ACTIONPOSSIBLE CAUSE OR ACTION

Low flow rateLow flow rate Piping / equipment is dirty or fouled. Discharge is restricted or Piping / equipment is dirty or fouled. Discharge is restricted or undersized. Gears on pump are worn or fouled.undersized. Gears on pump are worn or fouled.

Pump runs, but no fluidPump runs, but no fluid Suction piping is restricted or plugged. Piping suction valve is closed. Suction piping is restricted or plugged. Piping suction valve is closed. Pump is rotating in the wrong direction.Pump is rotating in the wrong direction.

Pressure is lowPressure is low Line is restricted. Gears are worn or fouled.Line is restricted. Gears are worn or fouled.

Pump starts and stops runningPump starts and stops running Gears are worn or fouled. The suction line may be clogged. Suction Gears are worn or fouled. The suction line may be clogged. Suction piping is restricted or plugged.piping is restricted or plugged.

Excessive noise while pump is in Excessive noise while pump is in operationoperation

Pump head and gear may be misaligned. Pump mounting hardware Pump head and gear may be misaligned. Pump mounting hardware is loose. System pressure is excessive.is loose. System pressure is excessive.

Pump does not shut off at low Pump does not shut off at low levellevel

Float switch is faulty, defective or damaged. Low level relay is faulty, Float switch is faulty, defective or damaged. Low level relay is faulty, defective or damaged. Wiring is incorrect or shorted.defective or damaged. Wiring is incorrect or shorted.

System does not relieve pressure System does not relieve pressure properlyproperly

Pressure relief valve is clogged. Pressure relief valve is set Pressure relief valve is clogged. Pressure relief valve is set improperly.improperly.

Pump cycles on and off Pump cycles on and off repetitivelyrepetitively

Piping leak on discharge side. Pressure settings are adequate for Piping leak on discharge side. Pressure settings are adequate for system size or pressure.system size or pressure.

If you still need help, contact us..

Page 28: GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial

Last Home Back Next

Contact Us Contact Us

Mailing Address:Mailing Address:General Treatment ProductsGeneral Treatment ProductsP.O. Box 8697P.O. Box 8697Brea, CA 92822-5697Brea, CA 92822-5697

Phone:Phone: 714) 257-9165 714) 257-9165FAX:FAX: 714) 257-9215 714) 257-9215

Internet:Internet: http://www.gtpcompany.com http://www.gtpcompany.comE-Mail:E-Mail: [email protected] [email protected]

Shipping Address:Shipping Address:General Treatment ProductsGeneral Treatment Products254 Viking Ave.254 Viking Ave.Brea, CA 92821Brea, CA 92821