CONCRETE WALL WATERPROOFING GSKY SS FRAME 3/8" DIA SS WEDGE ANCHOR GSKY TOP TRIM GSKY SIDE TRIM GSKY STANDARD GREEN WALL PANEL SEE 8-p-2 FOR DRAIN DETAIL CONCRETE WALL WITH SMOOTH SURFACE 3/8" DIA SS WEDGE ANCHOR 2" 1 1/2" 6 1/2" 5" 3" 4" 11 7/8" TYP. GSKY SS FRAME WATERPROOFING GSKY TRIM MOUNTING ANGLE STAINLESS OR ALUMINUM GSKY SIDE TRIM SECURE INTO TRIM MOUNTING ANGLE GSKY STANDARD GREEN WALL PANEL SEE 10-p AND 11-p FOR IRRIGATION DETAIL GSKY TRIM MOUNTING ANGLE STAINLESS OR ALUMINUM GSKY TOP TRIM SECURE INTO TRIM MOUNTING ANGLE CONCRETE WALL WITH SMOOTH SURFACE WATERPROOFING GSKY STANDARD GREEN WALL PANEL 3/8" DIA SS WEDGE ANCHOR GSKY SS FRAME 5" 6 1/2" 3" 4" 11 7/8" GSKY IRRIGATION DRIP LINE 3/8" DIA SS WEDGE ANCHOR NEOPRENE WASHER BETWEEN WALL AND GSKY FRAME GSKY FRAME MIN 2" EMBED 1 1/2" 2" CONCRETE WALL WATERPROOFING 1 3D VIEW / CONCRETE WALL SCALE 3/8" - 1'-0" (FILE # 1-p-1) DESIGN NOTE: *STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM *WALL SURFACE MUST BE SMOOTH *WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED) *ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL) *WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED) *EMBEDDED PIPE OR CONDUIT LOCATIONS MUST BE INDICATED TO GSKY *TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL *GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS 2 PLAN DETAIL / CONCRETE WALL SCALE 3/4" - 1'-0" (FILE # 1-p-2) 3 SECTION DETAIL / CONCRETE WALL SCALE 3/4" - 1'-0" (FILE # 1-p-3) 4 FASTENER DETAIL / CONCRETE WALL SCALE 3" - 1'-0" (FILE # 1-p-4) #704 - 318 HOMER ST VANCOUVER, BC V6B 2V2 604-708-0611 ph 604-357-1315 fax www.gsky.com DRAWING # DRAWING TITLE: GSKY GREEN WALL PANELS DATE: REV DATE: SCALE: AUG 18, 2010 N/A PAPER SIZE: 11 x 17 3D VIEW PLAN DETAIL SECTION DETAIL FASTENER DETAIL CONCRETE WALL STRUCTURE / INTERIOR OR EXTERIOR AS NOTED 1-p

Upload: li-gallegos

Post on 22-Nov-2014

1.447 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: GSky Green Wall Spec Drawing Set V2.0

CONCRETE WALL

WATERPROOFING

GSKY SS FRAME

3/8" DIA SS WEDGE ANCHOR

GSKY TOP TRIM

GSKY SIDE TRIM

GSKY STANDARD

GREEN WALL PANEL

SEE 8-p-2 FOR DRAIN

DETAIL

CONCRETE WALL WITH

SMOOTH SURFACE

3/8" DIA SS WEDGE ANCHOR

2"

1 1/

2"

6 1/

2" 5"

3"

4" 11 7/8" TYP.

GSKY SS FRAME WATERPROOFING

GSKY TRIM MOUNTING ANGLE

STAINLESS OR ALUMINUM GSKY

SIDE TRIM SECURE INTO TRIM

MOUNTING ANGLE

GSKY STANDARD

GREEN WALL PANEL

SEE 10-p AND 11-p FOR

IRRIGATION DETAIL

GSKY TRIM MOUNTING

ANGLE

STAINLESS OR ALUMINUM

GSKY TOP TRIM SECURE

INTO TRIM MOUNTING ANGLE

CONCRETE WALL

WITH SMOOTH

SURFACE

WATERPROOFING

GSKY STANDARD

GREEN WALL PANEL

3/8" DIA SS WEDGE

ANCHOR

GSKY SS FRAME

5"

6 1/2"

3"4"11

7/8

"

GSKY IRRIGATION

DRIP LINE

3/8" DIA SS WEDGE

ANCHOR

NEOPRENE WASHER

BETWEEN WALL AND

GSKY FRAME

GSKY FRAME

MIN

2" E

MBE

D1

1/2"

2"

CONCRETE WALL

WATERPROOFING

1

3D VIEW / CONCRETE WALL

SCALE 3/8" - 1'-0" (FILE # 1-p-1)

DESIGN NOTE:

*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM

*WALL SURFACE MUST BE SMOOTH

*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)

*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)

*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)

*EMBEDDED PIPE OR CONDUIT LOCATIONS MUST BE INDICATED TO GSKY

*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL

*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

2

PLAN DETAIL / CONCRETE WALL

SCALE 3/4" - 1'-0" (FILE # 1-p-2)

3

SECTION DETAIL / CONCRETE WALL

SCALE 3/4" - 1'-0" (FILE # 1-p-3)

4

FASTENER DETAIL / CONCRETE WALL

SCALE 3" - 1'-0" (FILE # 1-p-4)

#704 - 318 HOMER ST

VANCOUVER, BC V6B 2V2

604-708-0611 ph 604-357-1315 fax

www.gsky.com

DRAWING #

DRAWING TITLE:

GSKY GREEN WALL PANELS

DATE:

REV DATE:

SCALE:AUG 18, 2010

N/A PAPER SIZE: 11 x 17

3D VIEW

PLAN DETAIL

SECTION DETAIL

FASTENER DETAIL

CONCRETE WALL STRUCTURE / INTERIOR OR EXTERIOR

AS NOTED

1-p

Page 2: GSky Green Wall Spec Drawing Set V2.0

WATERPROOFING

GSKY SS FRAME

3/8" DIA CONCRETE ANCHOR

CMU WALL (VOID MUST BE FILLED)

GSKY TOP TRIM

GSKY SIDE TRIM

GSKY STANDARD

GREEN WALL PANEL

SEE 8-p-1 FOR

DRAIN DETAIL

CMU WALL (VOID MUST BE

FILLED)

3/8" DIA CONCRETE

ANCHOR

2"

1 1/

2"

6 1/

2" 5"

3"

4" 11 7/8" TYP.

GSKY SS FRAME WATERPROOFING

GSKY TRIM MOUNTING ANGLE

STAINLESS OR ALUMINUM GSKY

SIDE TRIM SECURE INTO TRIM

MOUNTING ANGLE

GSKY STANDARD

GREEN WALL PANEL

SEE 10-p AND 11-p FOR

IRRIGATION DETAIL

GSKY TRIM MOUNTING

ANGLE

STAINLESS OR ALUMINUM

GSKY TOP TRIM SECURE

INTO TRIM MOUNTING ANGLE

GSKY STANDARD

GREEN WALL PANEL

GSKY SS FRAME

5"

6 1/2"

3"4"11

7/8

"

GSKY IRRIGATION

DRIP LINE

CMU WALL (VOID

MUST BE FILLED)

WATERPROOFING

3/8" DIA CONCRETE

ANCHOR

1 1/

2"

2"

3/8" DIA SS CONCRETE

ANCHOR

NEOPRENE WASHER

BETWEEN WALL AND

GSKY FRAME

GSKY FRAME

CMU WALL WITH

FILLED VOID

WATERPROOFING

DESIGN NOTE:

*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM

*WALL SURFACE MUST BE SMOOTH

*CMU VOID SPACE MUST BE FILLED WITH MORTAR FOR ANCHORING

*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)

*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)

*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)

*EMBEDDED PIPE OR CONDUIT LOCATIONS MUST BE INDICATED TO GSKY

*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL

*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

1

3D VIEW / CMU WALL

SCALE 3/8" - 1'-0" (FILE # 2-p-1)

2

PLAN DETAIL / CMU WALL

SCALE 3/4" - 1'-0" (FILE # 2-p-2)

3

SECTION DETAIL / CMU WALL

SCALE 3/4" - 1'-0" (FILE # 2-p-3)

4

FASTENER DETAIL / CMU WALL

SCALE 3" - 1'-0" (FILE # 2-p-4)

#704 - 318 HOMER ST

VANCOUVER, BC V6B 2V2

604-708-0611 ph 604-357-1315 fax

www.gsky.com

DRAWING #

DRAWING TITLE:

GSKY GREEN WALL PANELS

DATE:

REV DATE:

SCALE:AUG 18, 2010

N/A PAPER SIZE: 11 x 17

3D VIEW

PLAN DETAIL

SECTION DETAIL

FASTENER DETAIL

CMU WALL STRUCTURE / INTERIOR OR EXTERIOR

AS NOTED

2-p

Page 3: GSky Green Wall Spec Drawing Set V2.0

2x6 BLOCKING AT GSKY FRAME

SCREW LOCATIONS MAY BE

REQUIRED (CHECK WITH

PROJECT ENGINEER)

GSKY SS FRAME

1/4" DIA WOOD OR METAL

SCREW

STUD WALL STRUCTUREGSKY TOP TRIM

GSKY SIDE TRIM

GSKY STANDARD

GREEN WALL PANEL

WATERPROOFING

3/4" PLYWOOD BEHIND GREEN

WALL

WALL FINISH TO MAKE

RECESSED GREEN

WALL OPTION

SEE 8-p-1 FOR

DRAIN DETAIL

2x6 BLOCKING AT GSKY FRAME

SCREW LOCATION MAYBE

REQUIRED (CHECK WITH

PROJECT ENGINEER)

1/4" DIA WOOD OR

METAL SCREW

2"

1 1/

2"

5"

3"

4" 11 7/8" TYP.

GSKY SS FRAME

WATERPROOFING

GSKY TRIM MOUNTING ANGLE

STAINLESS OR ALUMINUM GSKY

SIDE TRIM SECURE INTO TRIM

MOUNTING ANGLE

GSKY STANDARD

GREEN WALL PANEL

GREEN WALL CAN BE

RECESSED INTO

WALL FINISH

3/4" PLYWOOD BEHIND GREEN

WALL

WOOD OR METAL STUD

WALL STRUCTURE

SEE 10-p AND 11-p FOR

IRRIGATION DETAIL

GSKY TRIM MOUNTING

ANGLE

STAINLESS OR ALUMINUM

GSKY TOP TRIM SECURE

INTO TRIM MOUNTING ANGLE

GSKY STANDARD

GREEN WALL PANEL

GSKY SS FRAME

5"

6 1/2"

3"4"11

7/8

"

GSKY IRRIGATION

DRIP LINE

WATERPROOFING

1/4" DIA WOOD OR

METAL SCREW

WOOD OR METAL STUD

WALL STRUCTURE

3/4" PLYWOOD

BEHIND GREEN WALL

2x6 BLOCKING AT GSKY

FRAME SCREW LOCATION

MAYBE REQUIRED (CHECK

WITH PROJECT ENGINEER)

1 1/

2"

2"

1/4" DIA SS WOOD OR

METAL SCREW

NEOPRENE WASHER

BETWEEN WALL AND

GSKY FRAME

GSKY FRAME

WATERPROOFING

3/4" PLYWOOD BEHIND

GREEN WALL

2x6 BLOCKING AT GSKY

FRAME SCREW LOCATION

MAYBE REQUIRED (CHECK

WITH PROJECT ENGINEER)

DESIGN NOTE:

*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM

*WALL SURFACE MUST BE SMOOTH

*3/4" PLYWOOD MUST BE INSTALLED BEHIND GREEN WALL AREA

*BLOCKING AT GSKY FRAME SCREW LOCATIONS MAY BE REQUIRED CHECK WITH PROJECT ENGINEER

*STUD LOCATION MUST BE IDENTIFIED ON THE AS-BUILT DRAWING

*GREEN WALL CAN BE RECESSED AT INDOOR WALL (NOTE THAT GUTTER WILL EXTEND OUT; SEE 8-p-1 FOR DETAIL)

*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)

*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)

*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)

*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL

*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

1

3D VIEW / STUD WALL

SCALE 3/8" - 1'-0" (FILE # 3-p-1)

2

PLAN DETAIL / STUD WALL

SCALE 3/4" - 1'-0" (FILE # 3-p-2)

3

SECTION DETAIL / STUD WALL

SCALE 3/4" - 1'-0" (FILE # 3-p-3)

4

FASTENER DETAIL / STUD WALL

SCALE 3" - 1'-0" (FILE # 3-p-4)

#704 - 318 HOMER ST

VANCOUVER, BC V6B 2V2

604-708-0611 ph 604-357-1315 fax

www.gsky.com

DRAWING #

DRAWING TITLE:

GSKY GREEN WALL PANELS

DATE:

REV DATE:

SCALE:AUG 18, 2010

N/A PAPER SIZE: 11 x 17

3D VIEW

PLAN DETAIL

SECTION DETAIL

FASTENER DETAIL

STUD WALL STRUCTURE / INTERIOR OR EXTERIOR

AS NOTED

3-p

Page 4: GSky Green Wall Spec Drawing Set V2.0

STEEL STRUCTURE

GSKY SS FRAME

1/4" DIA SS SELF TAPPING

SCREW

INSULATION AS REQUIRED

GSKY TOP TRIM

GSKY SIDE TRIM

GSKY STANDARD

GREEN WALL PANEL

HORIZONTAL STEEL MEMBER

AT GSKY FRAME SCREW

LOCATIONS

BACK COVER

SOLID GROUND FINISH FOR

MAINTENANCE ACCESS BASED

ON THE SIZE OF GREEN WALL

SEE 8-p-3 FOR

DRAIN DETAIL

INSULATION AS REQUIRED

BY GSKY

STEEL STRUCTURE

2"

1 1/

2"

6 1/

2" 5"

3"

4" 11 7/8" TYP.

GSKY SS FRAME

HORIZONTAL STEEL MEMBER

AT GSKY FRAME SCREW

LOCATIONS BY OTHERS

GSKY TRIM MOUNTING ANGLE

STAINLESS OR ALUMINUM GSKY

SIDE TRIM SECURE INTO TRIM

MOUNTING ANGLE

GSKY STANDARD

GREEN WALL PANEL

1/4" DIA SS SELF

TAPPING SCREW

BACK COVER

SEE 10-p AND 11-p FOR

IRRIGATION DETAIL

GSKY TRIM MOUNTING

ANGLE

STAINLESS OR ALUMINUM

GSKY TOP TRIM SECURE

INTO TRIM MOUNTING ANGLE

GSKY STANDARD

GREEN WALL PANEL

GSKY SS FRAME

5"

6 1/2"

3"4"11

7/8

"

GSKY IRRIGATION

DRIP LINE

STEEL STRUCTURE

HORIZONTAL STEEL

MEMBER AT GSKY

FRAME SCREW

LOCATIONS

1/4" DIA SS SELF

TAPPING SCREW

BACK COVER

1/4" DIA SS SELF

TAPPING SCREW

NEOPRENE WASHER

BETWEEN WALL AND

GSKY FRAME

GSKY FRAME

1 1/

2"

2"

HORIZONTAL STEEL

MEMBER AT GSKY FRAME

SCREW LOCATIONS

DESIGN NOTE:

*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM

*WALL SURFACE MUST BE SMOOTH

*HORIZONTAL STEEL MEMBER MUST LINE UP WITH GSKY FRAME SCREW LOCATIONS; ASK GSKY FOR CONSULTANT

*WATERPROOFING MAY BE REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)

*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)

*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)

*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL

*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

1

3D VIEW / STEEL WALL

SCALE 3/8" - 1'-0" (FILE # 4-p-1)

2

PLAN DETAIL / STEEL WALL

SCALE 3/4" - 1'-0" (FILE # 3-p-2)

3

SECTION DETAIL / STEEL WALL

SCALE 3/4" - 1'-0" (FILE # 3-p-3)

4

FASTENER DETAIL / STEEL WALL

SCALE 3" - 1'-0" (FILE # 4-p-4)

#704 - 318 HOMER ST

VANCOUVER, BC V6B 2V2

604-708-0611 ph 604-357-1315 fax

www.gsky.com

DRAWING #

DRAWING TITLE:

GSKY GREEN WALL PANELS

DATE:

REV DATE:

SCALE:AUG 18, 2010

N/A PAPER SIZE: 11 x 17

3D VIEW

PLAN DETAIL

SECTION DETAIL

FASTENER DETAIL

STEEL WALL STRUCTURE / INTERIOR OR EXTERIOR

AS NOTED

4-p

Page 5: GSky Green Wall Spec Drawing Set V2.0

STEEL STRUCTURE

GSKY SS FRAME

1/4" DIA SS SELF

TAPPING SCREW

GSKY TOP TRIM

GSKY SIDE TRIM

GSKY STANDARD

GREEN WALL PANEL

HORIZONTAL STEEL MEMBER

AT GSKY FRAME SCREW

LOCATIONS

SOLID GROUND FINISH FOR

MAINTENANCE ACCESS BASED

ON THE SIZE OF GREEN WALL

SEE 8-p-3 FOR

DRAIN DETAIL

2"

1 1/

2"

6 1/

2" 5"

3"

4" 11 7/8" TYP.

GSKY SS FRAME

HORIZONTAL STEEL MEMBER

AT GSKY FRAME SCREW

LOCATIONS

GSKY TRIM MOUNTING ANGLE

STAINLESS OR ALUMINUM GSKY

SIDE TRIM SECURE INTO TRIM

MOUNTING ANGLE

GSKY STANDARD

GREEN WALL PANEL

1/4" DIA SS SELF

TAPPING SCREW

SEE 10-p AND 11-p FOR

IRRIGATION DETAIL

GSKY TRIM MOUNTING

ANGLE

STAINLESS OR ALUMINUM

GSKY TOP TRIM SECURE

INTO TRIM MOUNTING ANGLE

GSKY STANDARD

GREEN WALL PANEL

GSKY SS FRAME

5"

6 1/2"

3"4"11

7/8

"

GSKY IRRIGATION

DRIP LINE

STEEL STRUCTURE

BY OTHERS

HORIZONTAL STEEL

MEMBER AT GSKY

FRAME SCREW

LOCATIONS BY OTHERS

1/4" DIA SS SELF

TAPPING SCREW

BY GSKY

1 1/

2"

2"

1/4" DIA SS SELF

TAPPING SCREW

NEOPRENE WASHER

BETWEEN WALL AND

GSKY FRAME

GSKY FRAME

HORIZONTAL STEEL

MEMBER AT GSKY FRAME

SCREW LOCATIONS

DESIGN NOTE:

*STRUCTURE TYPE SHOWN ON 1-p, 2-p, 3-p AND 4-p CAN BE USED

*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM

*WALL SURFACE MUST BE SMOOTH

*HORIZONTAL STEEL MEMBER MUST LINE UP WITH GSKY FRAME SCREW LOCATIONS; ASK GSKY FOR CONSULTANT

*WATERPROOFING MAY BE REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)

*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)

*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)

*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL

*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

1

3D VIEW / DOUBLE SIDED WALL

SCALE 3/8" - 1'-0" (FILE # 5-p-1)

2

PLAN DETAIL / DOUBLE SIDED WALL

SCALE 3/4" - 1'-0" (FILE # 5-p-2)

3

SECTION DETAIL / DOUBLE SIDED WALL

SCALE 3/4" - 1'-0" (FILE # 5-p-3)

4

FASTENER DETAIL / DOUBLE SIDED WALL

SCALE 3" - 1'-0" (FILE # 5-p-4)

#704 - 318 HOMER ST

VANCOUVER, BC V6B 2V2

604-708-0611 ph 604-357-1315 fax

www.gsky.com

DRAWING #

DRAWING TITLE:

GSKY GREEN WALL PANELS

DATE:

REV DATE:

SCALE:AUG 18, 2010

N/A PAPER SIZE: 11 x 17

3D VIEW

PLAN DETAIL

SECTION DETAIL

FASTENER DETAIL

DOUBLE SIDED WALL STRUCTURE / INTERIOR OR EXTERIOR

AS NOTED

5-p

Page 6: GSky Green Wall Spec Drawing Set V2.0

BLOCKING MATERIAL TO

SECURE GSKY FRAME BY

OTHERS (CHECK WITH

BUILDING ENVELOPE

CONSULTANT FOR THERMAL

BRIDGE)

GSKY SS FRAME

1/4" DIA WOOD OR METAL

SCREW

CONCRETE STRUCTUREGSKY TOP TRIM

GSKY SIDE TRIM

GSKY STANDARD

GREEN WALL PANEL

EIFS SYSTEM

WATERPROOFING

3/4" PLYWOOD BEHIND GREEN

WALL

SEE 8-p-4 FOR

DRAIN DETAIL

CONCRETE WALL WITH

SMOOTH SURFACE

2"

1 1/

2"

6 1/

2" 8 3/

4"

3"

4" 11 7/8" TYP.

GSKY SS FRAME WATERPROOFING

GSKY TRIM MOUNTING ANGLE

STAINLESS OR ALUMINUM GSKY

SIDE TRIM SECURE INTO TRIM

MOUNTING ANGLE

GSKY STANDARD

GREEN WALL PANEL

1/4" DIA WOOD OR

METAL SCREW

BLOCKING MATERIAL TO

SECURE GSKY FRAME

3/4" PLYWOOD BEHIND

GREEN WALL

WALL FINISH

SEE 10-p AND 11-p FOR

IRRIGATION DETAIL

GSKY TRIM MOUNTING

ANGLE

STAINLESS OR ALUMINUM

GSKY TOP TRIM SECURE

INTO TRIM MOUNTING ANGLE

CONCRETE WALL

WITH SMOOTH

SURFACE

WATERPROOFING

GSKY STANDARD

GREEN WALL PANEL

GSKY SS FRAME

5"

6 1/2"

3"4"11

7/8

"

GSKY IRRIGATION

DRIP LINE

1/4" DIA WOOD OR

METAL SCREW

WALL FINISH

BLOCKING MATERIAL TO

SECURE GSKY FRAME

3/4" PLYWOOD BEHIND

GREEN WALL

EIFS SYSTEM

1 1/

2"

2"

NEOPRENE WASHER

BETWEEN WALL AND

GSKY FRAME

GSKY FRAME

BLOCKING MATERIAL TO

SECURE GSKY FRAME

WATERPROOFING

3/4" PLYWOOD BEHIND

GREEN WALL

1/4" DIA SS WOOD OR

METAL SCREW

DESIGN NOTE:

*STRUCTURE TYPE SHOWN ON 1-p, 2-p, 3-p AND 4-p CAN BE USED

*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM

*WALL SURFACE MUST BE SMOOTH

*3/4" PLYWOOD MUST BE INSTALLED BEHIND GREEN WALL AREA

*BLOCKING AT GSKY FRAME SCREW LOCATIONS MUST BE INSTALLED; CHECK WITH ENVELOPE CONSULTANT FOR THERMAL BRIDGE

*WATERPROOFING IS REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)

*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)

*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)

*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL

*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

1

3D VIEW / EIFS WALL

SCALE 3/8" - 1'-0" (FILE # 6-p-1)

2

PLAN DETAIL / EIFS WALL

SCALE 3/4" - 1'-0" (FILE # 6-p-2)

3

SECTION DETAIL / EIFS WALL

SCALE 3/4" - 1'-0" (FILE # 6-p-3)

4

FASTENER DETAIL / EIFS WALL

SCALE 3" - 1'-0" (FILE # 6-p-4)

#704 - 318 HOMER ST

VANCOUVER, BC V6B 2V2

604-708-0611 ph 604-357-1315 fax

www.gsky.com

DRAWING #

DRAWING TITLE:

GSKY GREEN WALL PANELS

DATE:

REV DATE:

SCALE:AUG 18, 2010

N/A PAPER SIZE: 11 x 17

3D VIEW

PLAN DETAIL

SECTION DETAIL

FASTENER DETAIL

EIFS WALL STRUCTURE / INTERIOR OR EXTERIOR

AS NOTED

6-p

Page 7: GSky Green Wall Spec Drawing Set V2.0

SEE 7-p-3 FOR GSKY

CORNER PANEL

DETAIL

SEE 7-p-2 FOR GSKY

CORNER TRIM

DETAIL

SEE 7-p-4 FOR

GUTTER OVER

OPENING

11 7/8" TYP. 6 3/4"

6 3/

4"

CORNER TRIM

MOUNTING

BRACKET 3' O/C

STAINLESS OR

ALUMINUM GSKY

CORNER TRIM

5"

11 7/8" TYP. 5"

5"

GSKY CORNER

PANEL

GSKY CORNER

PANEL MOUNTING

BRACKET

STAINLESS OR ALUMINUM

GSKY GUTTER DRAIN

OVER OPENING

DRAIN PIPE TO DIRECT

WATER FROM GUTTER TO

MAIN DRAINAGE (RUN

DRAIN PIPE IN SIDE TRIM) SEE 8-p FOR MIN WIDTH

LINE OF SIDE TRIM

(TRIM WIDTH CAN

MATCH WITH WITH

GUTTER WIDTH)

4"

1

3D VIEW FOR TYPICAL DETAILS

SCALE NTS (FILE # 7-p-1)

2

PLAN DETAIL / CORNER TRIM

SCALE 1" - 1'-0" (FILE # 7-p-2)

#704 - 318 HOMER ST

VANCOUVER, BC V6B 2V2

604-708-0611 ph 604-357-1315 fax

www.gsky.com

DRAWING #

DRAWING TITLE:

GSKY GREEN WALL PANELS

DATE:

REV DATE:

SCALE:AUG 18, 2010

N/A PAPER SIZE: 11 x 17

3D VIEW

CORNER TRIM

CORNER PANEL

GUTTER OVER OPENING

TYPICAL DETAILS / INTERIOR OR EXTERIOR

AS NOTED

7-p

3

PLAN DETAIL / CORNER PANEL

SCALE 1" - 1'-0" (FILE # 7-p-3)

4

SECTION DETAIL / GUTTER OVER OPENING

SCALE 1" - 1'-0" (FILE # 7-p-4)

Page 8: GSky Green Wall Spec Drawing Set V2.0

4"

SEE TABLE FOR MIN WIDTH

STAINLESS OR

ALUMINUM GUTTER

DRAIN

2" DRAIN PIPE WITH

SCREEN COVER

STRIP OF MEMBRANE

OVER GUTTER

SEE TABLE FOR MIN WIDTH

WATERPROOFING

MIN

6"

DRAIN AREA WITH

GRAVEL

HARD SURFACE FOR

MAINTENANCE WITH LIFT

PERFORATED

DRAINAGE PIPE

SEE TABLE FOR MIN WIDTH

DRAIN AREA WITH

GRAVEL

2" DRAIN PIPE WITH

SCREEN COVER

FINISHED CURB

AROUND DRAIN AREA

WATERPROOFING

MIN

6"

± 6"

SEE TABLE FOR MIN WIDTH

METAL GRATING COVER

TRENCH DRAIN AREA

2" DRAIN PIPE WITH

SCREEN COVER

SLOPED FLOOR FINISH

WATERPROOFING

1

SECTION DETAIL / GUTTER DRAIN

SCALE 1" - 1'-0" (FILE # 8-p-1)

GUTTER DRAIN

HEIGHT: LESS THAN 16 PANELS HEIGHT: BETWEEN 16 AND 24 PANELS

TRENCH DRAIN

GROUND DRAIN

CURB DRAIN

MIN 12" NOT ADEQUATE

MIN 24"

MIN 36" (ASK GSKY)

MIN 12"

*DRAIN AREA SHOULD EXTEND MIN 1/2 DRAIN WIDTH FROM EACH SIDES OF GREEN WALL

*MIN WIDTH MAY CHANGE DEPENDING ON PLANT SELECTION

*WATERPROOFING IN TRENCH AND CURB DRAIN ARE REQUIRED

*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

HEIGHT: MORE THAN 24 PANELS

NOT ADEQUATE

MIN 24"

MIN 36" (ASK GSKY)

MIN 12"

MIN 24"

MIN 36" (ASK GSKY)

MIN 12"

#704 - 318 HOMER ST

VANCOUVER, BC V6B 2V2

604-708-0611 ph 604-357-1315 fax

www.gsky.com

DRAWING #

DRAWING TITLE:

GSKY GREEN WALL PANELS

DATE:

REV DATE:

SCALE:AUG 18, 2010

N/A PAPER SIZE: 11 x 17

GUTTER DRAIN

GRAVEL DRAIN

TRENCH DRAIN

CURB DRAIN

DRAIN DETAILS / INTERIOR OR EXTERIOR

AS NOTED

8-p

2

SECTION DETAIL / TRENCH DRAIN

SCALE 1" - 1'-0" (FILE # 8-p-2)

3

SECTION DETAIL / GRAVEL DRAIN

SCALE 1" - 1'-0" (FILE # 8-p-3)

4

SECTION DETAIL / CURB DRAIN

SCALE 1" - 1'-0" (FILE # 8-p-4)

Page 9: GSky Green Wall Spec Drawing Set V2.0

*REQUIREMENTS:

*ICU - 48"h x 24"w x 36"d (INCLUDING DOOR SWING)

*CONTROLLER - 13"h x 15"w x 20"d (INCLUDING DOOR SWING)

*EASY ACCESS FOR MAINTENANCE

*ADEQUATE PRESSURE TO GET MIN PSI AT BOTTOM OF GREEN WALL (TYP

65 PSI, UP TO 50 FT HEIGHT WALL)

INSTALL BOOSTER PUMP IF REQUIRED (BY PLUMBER)

*120V / 2 AMP POWER (HARD WIRE) (BY ELECTRICIAN)

*DEDICATED TELEPHONE LINE RJ 11 (FOR OTHERS)

*GROUNDING CONNECTION IF REQUIRED (BY ELECTRICIAN)

*1 1/4" CONDUIT BETWEEN ACC AND EACH TRIM SPACES FOR ZONE VALVE

CONTROL WIRES AND FREEZING SENSOR (BY ELECTRICIAN)

*BACK-FLOW PREVENTOR AS REQUIRED (BY PLUMBER)

*GREEN WALL MUST BE DESIGNED TO HAVE SPACE FOR ZONE VALVES TO

RUN ALONG THE SIDE OF THE GREEN WALL WITHIN THE SIDE TRIM (MIN 7"

WIDE TRIM) OR ABOVE THE WALL IN THE TOP TRIM (MIN 8" HIGH TRIM)

*NON-FREEZING INDOOR SPACE WITH FLOOR DRAIN

CONTROLLER / TIMER

HARD WIRE CONNECTION

120 VAC / 2 AMP IN CONDUIT

BY ELECTRICIAN

DEDICATED TELEPHONE LINE

WITH RJ 11 CONNECTION BY

ELECTRICIAN

CONDUIT WITH 16 GA SOLID

COPPER MULTI-STRAND

CABLE BY OTHERS

(# OF WIRES DETERMINED BY

# OF IRRIGATION ZONES AND

SENSORS ON THE WALL)

PRESSURE REGULATION

VALVE

FERTILIZER INJECTOR

FERTILIZER TANK

1" IRRIGATION MAIN LINE

INLET (SIZE MAY VARY)

2'1'-3"

1'-1

"

4'

1" CONDUIT BY G-SKY

FLOW SENSOR

REQUIRES MIN. 1' STRAIGHT

PIPE BEFORE AND AFTER

THE SENSOR

CONTROLLER / TIMER

HARD WIRE CONNECTION

120 VAC / 2 AMP IN CONDUIT

BY ELECTRICIAN

DEDICATED TELEPHONE LINE

WITH RJ 11 CONNECTION BY

ELECTRICIAN

PRESSURE REGULATION

VALVE

FERTILIZER INJECTOR

FERTILIZER TANK

1" IRRIGATION MAIN LINE

INLET (SIZE MAY VARY)

3'1'-3"

1'-1

"

4'

1" CONDUIT BY G-SKY

DEDICATED IRRIGATION ZONE

SUPPLY LINES FROM ICU TO

GREEN WALL BY OTHERS

3/4" FIPT STUB-OUTS ARE

REQUIRED; 1" SUPPLY LINE

MAY BE USED TO KEEP FLOW

TO STUB-OUT

FLOW SENSOR

REQUIRES MIN. 1'

STRAIGHT PIPE BEFORE

AND AFTER THE SENSOR

MASTER VALVE

GRAVITY DRAIN VALVE FOR

AUTOMATED WINTERIZATION

*REQUIREMENTS:

*ICU - 48"h x 36"w x 48"d (INCLUDING DOOR SWING)

*CONTROLLER - 13"h x 15"w x 20"d (INCLUDING DOOR SWING)

*EASY ACCESS FOR MAINTENANCE

*ADEQUATE PRESSURE TO GET MIN PSI AT BOTTOM OF GREEN WALL (TYP

65 PSI, UP TO 50 FT HEIGHT WALL)

INSTALL BOOSTER PUMP IF REQUIRED (BY PLUMBER)

*120V / 2 AMP POWER (HARD WIRE) (BY ELECTRICIAN)

*DEDICATED TELEPHONE LINE RJ 11 (BY OTHERS)

*GROUNDING CONNECTION IF REQUIRED (BY ELECTRICIAN)

*BACK-FLOW PREVENTOR AS REQUIRED (BY PLUMBER)

*CAN BE EXPANDED MAX 6 ZONES TO ACCOMMODATE IF THERE IS NO

SPACE FOR VALVES AT THE GREEN WALL(S)

*NON-FREEZING INDOOR SPACE WITH FLOOR DRAIN

*CAN BE LOCATED OUTDOORS WITH ADDITIONAL ENCLOSURE

*CAN BE CUSTOM DESIGNED TO ACCOMMODATE FREEZING CLIMATES

ICU-600

IRRIGATION CONTROL UNIT FOR:

*GREEN WALLS SMALLER THAN 1080 SQFT (INTERIOR OR EXTERIOR)

*EXTERIOR WALLS IN USDA PLANT ZONE 9 OR HIGHER (NON-FREEZING

CLIMATES)

ICU-1000

IRRIGATION CONTROL UNIT FOR:

*GREEN WALLS LARGER THAN 1080SQFT (INTERIOR OR EXTERIOR)

*EXTERIOR GREEN WALLS IN FREEZING CLIMATES USDA PLANT

ZONE 8 OR BELOW (USDA PLANT ZONE 8 = MAX 20F OR -6.7C)

DEDICATED IRRIGATION ZONE

SUPPLY LINES FROM ICU TO

GREEN WALL BY OTHERS

1" FIPT STUB-OUTS ARE REQUIRED

1

ICU-1000 / ZONE VALVES AT GREEN WAL

SCALE 3/4" - 1'-0" (FILE # 9-p-1)

2

ICU-600 / ZONE VALVES AT ICU

SCALE 3/4" - 1'-0" (FILE # 9-p-2)

#704 - 318 HOMER ST

VANCOUVER, BC V6B 2V2

604-708-0611 ph 604-357-1315 fax

www.gsky.com

DRAWING #

DRAWING TITLE:

GSKY GREEN WALL PANELS

DATE:

REV DATE:

SCALE:AUG 18, 2010

N/A PAPER SIZE: 11 x 17

ICU-1000

ICU-600

PLUMBING REQUIREMENTS

ELECTRICAL REQUIREMENTS

IRRIGATION CONTROL UNIT (ICU) DESIGNS

AS NOTED

9-p

Page 10: GSky Green Wall Spec Drawing Set V2.0

3/4" FIPT IRRIGATION

STU-OUT BY OTHERS

SEE DRAWING #1 FOR

STUB-OUT LOCATIONS

1 1/2"

4"

MAX

2"

S

S

S S

MAX 36 PANELS IN SINGLE ROW

MAX

5 P

ANEL

S HE

IGHT

IN S

INGL

E ZO

NE

CAN BE IN SAME ZONE IF 3 OUT

OF 5 ROWS IN SINGLE ZONE

ARE CONTIUOUS

IF MORE THAN 3 OUT 5 ROWS

ARE TERMINATED BY OPENING,

REQUIRE ANOTHER STUB-OUT

3/4" STUB-OUT WITH FIPT

CONNECTION (MAIN LINE

MAY BE 1" TO KEEP FLOW)

S

MAX 36 PANELS IN SINGLE ROW

MAX

5 P

ANEL

S HE

IGHT

IN S

INGL

E ZO

NE

Z Z Z Z

LOCATE ZONE VALVES WITH IN

TOP TRIM SPACE; MIN 8" TOP TRIM

SPACE IS REQUIRED

SINGLE IRRIGATION STUB-OUT

AND CONDUIT FOR ICU-1000; SEE

9-p FOR REQUIREMENTS

C

F

INSTALL FREEZING AND REV

FREEZING SENSOR FOR

FREEZING REGION

D

D

D

D

LOCATE DRAIN VALVES AT

BOTTOM OF EACH ZONE FOR

FREEZING REGION

6 1/2"

8"

1" IRRIGATION

SUPPLY LINE FROM

STUB-OUT

CONTROL WIRES

(FREE WIRED OR IN

CONDUIT)

ZONE VALVES

GSKY TOP TRIM

MAX. 36 PANELS IN EACH CONTINUOUS ROW

MAX. 5 PANELS HEIGHT IN ONE ZONE

MAIN IRRIGATION SUPPLY LINE CAN BE COPPER, PEX OR PVC TO MEET

LOCAL CODE (BY PLUMBER)

STUB-OUT SHOULD BE INSTALLED WITH FEMALE PIPE THREAD FITTINGS

1

IRRIGATION LAYOUT FOR ICU-600 / ZONE VALVES AT ICU

SCALE NTS (FILE # 10-p-1)

2

IRRIGATION STUB-OUT DETAIL FOR ICU-600

SCALE 1-1/2" = 1'-0" (FILE # 10-p-2)

3

IRRIGATION LAYOUT FOR ICU-1000 / ZONE VALVES IN TOP TRIM

SCALE NTS (FILE # 10-p-3)

#704 - 318 HOMER ST

VANCOUVER, BC V6B 2V2

604-708-0611 ph 604-357-1315 fax

www.gsky.com

DRAWING #

DRAWING TITLE:

GSKY GREEN WALL PANELS

DATE:

REV DATE:

SCALE:AUG 18, 2010

N/A PAPER SIZE: 11 x 17

IRRIGATION LAYOUT FOR ICU-1000

IRRIGATION LAYOUT FOR ICU-600

STUB-OUT DETAIL

ZONE VALVE DETAIL

IRRIGATION LAYOUT 1

AS NOTED

10-p

4

ZONE VALVE DETAIL FOR ICU-1000 IN TOP TRIM

SCALE 1-1/2" = 1'-0" (FILE # 10-p-4)

Page 11: GSky Green Wall Spec Drawing Set V2.0

1" IRRIGATION

SUPPLY LINE FROM

STUB-OUT

CONTROL WIRES

(FREE WIRED OR IN

CONDUIT)

ZONE VALVES

GSKY TOP TRIM

6"

7"

6 1/

2"

S

MAX 36 PANELS IN SINGLE ROW

MAX

5 P

ANEL

S HE

IGHT

IN S

INGL

E ZO

NE

C

Z

Z

Z

Z

Z

Z

SINGLE IRRIGATION STUB-OUT

AND CONDUIT FOR ICU-1000; SEE

8-p FOR REQUIREMENTS

LOCATE ZONE VALVES WITH IN

SIDE TRIM SPACE; MIN 6" SIDE

TRIM SPACE IS REQUIRED

MAX

50

PAN

ELS

HEIG

HT

INSTALL FREEZING AND REV

FREEZING SENSOR FOR

FREEZING REGION

F

D

D

D

D

D

D

LOCATE DRAIN VALVES AT

BOTTOM OF EACH ZONE FOR

FREEZING REGION

MAX. 36 PANELS IN EACH CONTINUOUS ROW

MAX. 5 PANELS HEIGHT IN ONE ZONE

MAIN IRRIGATION SUPPLY LINE CAN BE COPPER, PEX OR PVC TO MEET

LOCAL CODE (BY PLUMBER)

STUB-OUT SHOULD BE INSTALLED WITH FEMALE PIPE THREAD FITTINGS

#704 - 318 HOMER ST

VANCOUVER, BC V6B 2V2

604-708-0611 ph 604-357-1315 fax

www.gsky.com

DRAWING #

DRAWING TITLE:

GSKY GREEN WALL PANELS

DATE:

REV DATE:

SCALE:AUG 18, 2010

N/A PAPER SIZE: 11 x 17

IRRIGATION LAYOUT FOR ICU-1000

ZONE VALVE DETAIL

-

-

IRRIGATION LAYOUT 2

AS NOTED

11-p

1

IRRIGATION LAYOUT FOR ICU-1000 / ZONE VALVES IN SIDE TRIM

SCALE NTS (FILE # 11-p-1)

2

ZONE VALVE DETAIL FOR ICU-1000 IN TOP TRIM

SCALE 1-1/2" = 1'-0" (FILE # 11-p-2)