gsky green wall spec drawing set v2.0
TRANSCRIPT
CONCRETE WALL
WATERPROOFING
GSKY SS FRAME
3/8" DIA SS WEDGE ANCHOR
GSKY TOP TRIM
GSKY SIDE TRIM
GSKY STANDARD
GREEN WALL PANEL
SEE 8-p-2 FOR DRAIN
DETAIL
CONCRETE WALL WITH
SMOOTH SURFACE
3/8" DIA SS WEDGE ANCHOR
2"
1 1/
2"
6 1/
2" 5"
3"
4" 11 7/8" TYP.
GSKY SS FRAME WATERPROOFING
GSKY TRIM MOUNTING ANGLE
STAINLESS OR ALUMINUM GSKY
SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE
GSKY STANDARD
GREEN WALL PANEL
SEE 10-p AND 11-p FOR
IRRIGATION DETAIL
GSKY TRIM MOUNTING
ANGLE
STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
CONCRETE WALL
WITH SMOOTH
SURFACE
WATERPROOFING
GSKY STANDARD
GREEN WALL PANEL
3/8" DIA SS WEDGE
ANCHOR
GSKY SS FRAME
5"
6 1/2"
3"4"11
7/8
"
GSKY IRRIGATION
DRIP LINE
3/8" DIA SS WEDGE
ANCHOR
NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
GSKY FRAME
MIN
2" E
MBE
D1
1/2"
2"
CONCRETE WALL
WATERPROOFING
1
3D VIEW / CONCRETE WALL
SCALE 3/8" - 1'-0" (FILE # 1-p-1)
DESIGN NOTE:
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*EMBEDDED PIPE OR CONDUIT LOCATIONS MUST BE INDICATED TO GSKY
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
2
PLAN DETAIL / CONCRETE WALL
SCALE 3/4" - 1'-0" (FILE # 1-p-2)
3
SECTION DETAIL / CONCRETE WALL
SCALE 3/4" - 1'-0" (FILE # 1-p-3)
4
FASTENER DETAIL / CONCRETE WALL
SCALE 3" - 1'-0" (FILE # 1-p-4)
#704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com
DRAWING #
DRAWING TITLE:
GSKY GREEN WALL PANELS
DATE:
REV DATE:
SCALE:AUG 18, 2010
N/A PAPER SIZE: 11 x 17
3D VIEW
PLAN DETAIL
SECTION DETAIL
FASTENER DETAIL
CONCRETE WALL STRUCTURE / INTERIOR OR EXTERIOR
AS NOTED
1-p
WATERPROOFING
GSKY SS FRAME
3/8" DIA CONCRETE ANCHOR
CMU WALL (VOID MUST BE FILLED)
GSKY TOP TRIM
GSKY SIDE TRIM
GSKY STANDARD
GREEN WALL PANEL
SEE 8-p-1 FOR
DRAIN DETAIL
CMU WALL (VOID MUST BE
FILLED)
3/8" DIA CONCRETE
ANCHOR
2"
1 1/
2"
6 1/
2" 5"
3"
4" 11 7/8" TYP.
GSKY SS FRAME WATERPROOFING
GSKY TRIM MOUNTING ANGLE
STAINLESS OR ALUMINUM GSKY
SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE
GSKY STANDARD
GREEN WALL PANEL
SEE 10-p AND 11-p FOR
IRRIGATION DETAIL
GSKY TRIM MOUNTING
ANGLE
STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
GSKY STANDARD
GREEN WALL PANEL
GSKY SS FRAME
5"
6 1/2"
3"4"11
7/8
"
GSKY IRRIGATION
DRIP LINE
CMU WALL (VOID
MUST BE FILLED)
WATERPROOFING
3/8" DIA CONCRETE
ANCHOR
1 1/
2"
2"
3/8" DIA SS CONCRETE
ANCHOR
NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
GSKY FRAME
CMU WALL WITH
FILLED VOID
WATERPROOFING
DESIGN NOTE:
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*CMU VOID SPACE MUST BE FILLED WITH MORTAR FOR ANCHORING
*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*EMBEDDED PIPE OR CONDUIT LOCATIONS MUST BE INDICATED TO GSKY
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
1
3D VIEW / CMU WALL
SCALE 3/8" - 1'-0" (FILE # 2-p-1)
2
PLAN DETAIL / CMU WALL
SCALE 3/4" - 1'-0" (FILE # 2-p-2)
3
SECTION DETAIL / CMU WALL
SCALE 3/4" - 1'-0" (FILE # 2-p-3)
4
FASTENER DETAIL / CMU WALL
SCALE 3" - 1'-0" (FILE # 2-p-4)
#704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com
DRAWING #
DRAWING TITLE:
GSKY GREEN WALL PANELS
DATE:
REV DATE:
SCALE:AUG 18, 2010
N/A PAPER SIZE: 11 x 17
3D VIEW
PLAN DETAIL
SECTION DETAIL
FASTENER DETAIL
CMU WALL STRUCTURE / INTERIOR OR EXTERIOR
AS NOTED
2-p
2x6 BLOCKING AT GSKY FRAME
SCREW LOCATIONS MAY BE
REQUIRED (CHECK WITH
PROJECT ENGINEER)
GSKY SS FRAME
1/4" DIA WOOD OR METAL
SCREW
STUD WALL STRUCTUREGSKY TOP TRIM
GSKY SIDE TRIM
GSKY STANDARD
GREEN WALL PANEL
WATERPROOFING
3/4" PLYWOOD BEHIND GREEN
WALL
WALL FINISH TO MAKE
RECESSED GREEN
WALL OPTION
SEE 8-p-1 FOR
DRAIN DETAIL
2x6 BLOCKING AT GSKY FRAME
SCREW LOCATION MAYBE
REQUIRED (CHECK WITH
PROJECT ENGINEER)
1/4" DIA WOOD OR
METAL SCREW
2"
1 1/
2"
5"
3"
4" 11 7/8" TYP.
GSKY SS FRAME
WATERPROOFING
GSKY TRIM MOUNTING ANGLE
STAINLESS OR ALUMINUM GSKY
SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE
GSKY STANDARD
GREEN WALL PANEL
GREEN WALL CAN BE
RECESSED INTO
WALL FINISH
3/4" PLYWOOD BEHIND GREEN
WALL
WOOD OR METAL STUD
WALL STRUCTURE
SEE 10-p AND 11-p FOR
IRRIGATION DETAIL
GSKY TRIM MOUNTING
ANGLE
STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
GSKY STANDARD
GREEN WALL PANEL
GSKY SS FRAME
5"
6 1/2"
3"4"11
7/8
"
GSKY IRRIGATION
DRIP LINE
WATERPROOFING
1/4" DIA WOOD OR
METAL SCREW
WOOD OR METAL STUD
WALL STRUCTURE
3/4" PLYWOOD
BEHIND GREEN WALL
2x6 BLOCKING AT GSKY
FRAME SCREW LOCATION
MAYBE REQUIRED (CHECK
WITH PROJECT ENGINEER)
1 1/
2"
2"
1/4" DIA SS WOOD OR
METAL SCREW
NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
GSKY FRAME
WATERPROOFING
3/4" PLYWOOD BEHIND
GREEN WALL
2x6 BLOCKING AT GSKY
FRAME SCREW LOCATION
MAYBE REQUIRED (CHECK
WITH PROJECT ENGINEER)
DESIGN NOTE:
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*3/4" PLYWOOD MUST BE INSTALLED BEHIND GREEN WALL AREA
*BLOCKING AT GSKY FRAME SCREW LOCATIONS MAY BE REQUIRED CHECK WITH PROJECT ENGINEER
*STUD LOCATION MUST BE IDENTIFIED ON THE AS-BUILT DRAWING
*GREEN WALL CAN BE RECESSED AT INDOOR WALL (NOTE THAT GUTTER WILL EXTEND OUT; SEE 8-p-1 FOR DETAIL)
*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
1
3D VIEW / STUD WALL
SCALE 3/8" - 1'-0" (FILE # 3-p-1)
2
PLAN DETAIL / STUD WALL
SCALE 3/4" - 1'-0" (FILE # 3-p-2)
3
SECTION DETAIL / STUD WALL
SCALE 3/4" - 1'-0" (FILE # 3-p-3)
4
FASTENER DETAIL / STUD WALL
SCALE 3" - 1'-0" (FILE # 3-p-4)
#704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com
DRAWING #
DRAWING TITLE:
GSKY GREEN WALL PANELS
DATE:
REV DATE:
SCALE:AUG 18, 2010
N/A PAPER SIZE: 11 x 17
3D VIEW
PLAN DETAIL
SECTION DETAIL
FASTENER DETAIL
STUD WALL STRUCTURE / INTERIOR OR EXTERIOR
AS NOTED
3-p
STEEL STRUCTURE
GSKY SS FRAME
1/4" DIA SS SELF TAPPING
SCREW
INSULATION AS REQUIRED
GSKY TOP TRIM
GSKY SIDE TRIM
GSKY STANDARD
GREEN WALL PANEL
HORIZONTAL STEEL MEMBER
AT GSKY FRAME SCREW
LOCATIONS
BACK COVER
SOLID GROUND FINISH FOR
MAINTENANCE ACCESS BASED
ON THE SIZE OF GREEN WALL
SEE 8-p-3 FOR
DRAIN DETAIL
INSULATION AS REQUIRED
BY GSKY
STEEL STRUCTURE
2"
1 1/
2"
6 1/
2" 5"
3"
4" 11 7/8" TYP.
GSKY SS FRAME
HORIZONTAL STEEL MEMBER
AT GSKY FRAME SCREW
LOCATIONS BY OTHERS
GSKY TRIM MOUNTING ANGLE
STAINLESS OR ALUMINUM GSKY
SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE
GSKY STANDARD
GREEN WALL PANEL
1/4" DIA SS SELF
TAPPING SCREW
BACK COVER
SEE 10-p AND 11-p FOR
IRRIGATION DETAIL
GSKY TRIM MOUNTING
ANGLE
STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
GSKY STANDARD
GREEN WALL PANEL
GSKY SS FRAME
5"
6 1/2"
3"4"11
7/8
"
GSKY IRRIGATION
DRIP LINE
STEEL STRUCTURE
HORIZONTAL STEEL
MEMBER AT GSKY
FRAME SCREW
LOCATIONS
1/4" DIA SS SELF
TAPPING SCREW
BACK COVER
1/4" DIA SS SELF
TAPPING SCREW
NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
GSKY FRAME
1 1/
2"
2"
HORIZONTAL STEEL
MEMBER AT GSKY FRAME
SCREW LOCATIONS
DESIGN NOTE:
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*HORIZONTAL STEEL MEMBER MUST LINE UP WITH GSKY FRAME SCREW LOCATIONS; ASK GSKY FOR CONSULTANT
*WATERPROOFING MAY BE REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
1
3D VIEW / STEEL WALL
SCALE 3/8" - 1'-0" (FILE # 4-p-1)
2
PLAN DETAIL / STEEL WALL
SCALE 3/4" - 1'-0" (FILE # 3-p-2)
3
SECTION DETAIL / STEEL WALL
SCALE 3/4" - 1'-0" (FILE # 3-p-3)
4
FASTENER DETAIL / STEEL WALL
SCALE 3" - 1'-0" (FILE # 4-p-4)
#704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com
DRAWING #
DRAWING TITLE:
GSKY GREEN WALL PANELS
DATE:
REV DATE:
SCALE:AUG 18, 2010
N/A PAPER SIZE: 11 x 17
3D VIEW
PLAN DETAIL
SECTION DETAIL
FASTENER DETAIL
STEEL WALL STRUCTURE / INTERIOR OR EXTERIOR
AS NOTED
4-p
STEEL STRUCTURE
GSKY SS FRAME
1/4" DIA SS SELF
TAPPING SCREW
GSKY TOP TRIM
GSKY SIDE TRIM
GSKY STANDARD
GREEN WALL PANEL
HORIZONTAL STEEL MEMBER
AT GSKY FRAME SCREW
LOCATIONS
SOLID GROUND FINISH FOR
MAINTENANCE ACCESS BASED
ON THE SIZE OF GREEN WALL
SEE 8-p-3 FOR
DRAIN DETAIL
2"
1 1/
2"
6 1/
2" 5"
3"
4" 11 7/8" TYP.
GSKY SS FRAME
HORIZONTAL STEEL MEMBER
AT GSKY FRAME SCREW
LOCATIONS
GSKY TRIM MOUNTING ANGLE
STAINLESS OR ALUMINUM GSKY
SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE
GSKY STANDARD
GREEN WALL PANEL
1/4" DIA SS SELF
TAPPING SCREW
SEE 10-p AND 11-p FOR
IRRIGATION DETAIL
GSKY TRIM MOUNTING
ANGLE
STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
GSKY STANDARD
GREEN WALL PANEL
GSKY SS FRAME
5"
6 1/2"
3"4"11
7/8
"
GSKY IRRIGATION
DRIP LINE
STEEL STRUCTURE
BY OTHERS
HORIZONTAL STEEL
MEMBER AT GSKY
FRAME SCREW
LOCATIONS BY OTHERS
1/4" DIA SS SELF
TAPPING SCREW
BY GSKY
1 1/
2"
2"
1/4" DIA SS SELF
TAPPING SCREW
NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
GSKY FRAME
HORIZONTAL STEEL
MEMBER AT GSKY FRAME
SCREW LOCATIONS
DESIGN NOTE:
*STRUCTURE TYPE SHOWN ON 1-p, 2-p, 3-p AND 4-p CAN BE USED
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*HORIZONTAL STEEL MEMBER MUST LINE UP WITH GSKY FRAME SCREW LOCATIONS; ASK GSKY FOR CONSULTANT
*WATERPROOFING MAY BE REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
1
3D VIEW / DOUBLE SIDED WALL
SCALE 3/8" - 1'-0" (FILE # 5-p-1)
2
PLAN DETAIL / DOUBLE SIDED WALL
SCALE 3/4" - 1'-0" (FILE # 5-p-2)
3
SECTION DETAIL / DOUBLE SIDED WALL
SCALE 3/4" - 1'-0" (FILE # 5-p-3)
4
FASTENER DETAIL / DOUBLE SIDED WALL
SCALE 3" - 1'-0" (FILE # 5-p-4)
#704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com
DRAWING #
DRAWING TITLE:
GSKY GREEN WALL PANELS
DATE:
REV DATE:
SCALE:AUG 18, 2010
N/A PAPER SIZE: 11 x 17
3D VIEW
PLAN DETAIL
SECTION DETAIL
FASTENER DETAIL
DOUBLE SIDED WALL STRUCTURE / INTERIOR OR EXTERIOR
AS NOTED
5-p
BLOCKING MATERIAL TO
SECURE GSKY FRAME BY
OTHERS (CHECK WITH
BUILDING ENVELOPE
CONSULTANT FOR THERMAL
BRIDGE)
GSKY SS FRAME
1/4" DIA WOOD OR METAL
SCREW
CONCRETE STRUCTUREGSKY TOP TRIM
GSKY SIDE TRIM
GSKY STANDARD
GREEN WALL PANEL
EIFS SYSTEM
WATERPROOFING
3/4" PLYWOOD BEHIND GREEN
WALL
SEE 8-p-4 FOR
DRAIN DETAIL
CONCRETE WALL WITH
SMOOTH SURFACE
2"
1 1/
2"
6 1/
2" 8 3/
4"
3"
4" 11 7/8" TYP.
GSKY SS FRAME WATERPROOFING
GSKY TRIM MOUNTING ANGLE
STAINLESS OR ALUMINUM GSKY
SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE
GSKY STANDARD
GREEN WALL PANEL
1/4" DIA WOOD OR
METAL SCREW
BLOCKING MATERIAL TO
SECURE GSKY FRAME
3/4" PLYWOOD BEHIND
GREEN WALL
WALL FINISH
SEE 10-p AND 11-p FOR
IRRIGATION DETAIL
GSKY TRIM MOUNTING
ANGLE
STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
CONCRETE WALL
WITH SMOOTH
SURFACE
WATERPROOFING
GSKY STANDARD
GREEN WALL PANEL
GSKY SS FRAME
5"
6 1/2"
3"4"11
7/8
"
GSKY IRRIGATION
DRIP LINE
1/4" DIA WOOD OR
METAL SCREW
WALL FINISH
BLOCKING MATERIAL TO
SECURE GSKY FRAME
3/4" PLYWOOD BEHIND
GREEN WALL
EIFS SYSTEM
1 1/
2"
2"
NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
GSKY FRAME
BLOCKING MATERIAL TO
SECURE GSKY FRAME
WATERPROOFING
3/4" PLYWOOD BEHIND
GREEN WALL
1/4" DIA SS WOOD OR
METAL SCREW
DESIGN NOTE:
*STRUCTURE TYPE SHOWN ON 1-p, 2-p, 3-p AND 4-p CAN BE USED
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*3/4" PLYWOOD MUST BE INSTALLED BEHIND GREEN WALL AREA
*BLOCKING AT GSKY FRAME SCREW LOCATIONS MUST BE INSTALLED; CHECK WITH ENVELOPE CONSULTANT FOR THERMAL BRIDGE
*WATERPROOFING IS REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
1
3D VIEW / EIFS WALL
SCALE 3/8" - 1'-0" (FILE # 6-p-1)
2
PLAN DETAIL / EIFS WALL
SCALE 3/4" - 1'-0" (FILE # 6-p-2)
3
SECTION DETAIL / EIFS WALL
SCALE 3/4" - 1'-0" (FILE # 6-p-3)
4
FASTENER DETAIL / EIFS WALL
SCALE 3" - 1'-0" (FILE # 6-p-4)
#704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com
DRAWING #
DRAWING TITLE:
GSKY GREEN WALL PANELS
DATE:
REV DATE:
SCALE:AUG 18, 2010
N/A PAPER SIZE: 11 x 17
3D VIEW
PLAN DETAIL
SECTION DETAIL
FASTENER DETAIL
EIFS WALL STRUCTURE / INTERIOR OR EXTERIOR
AS NOTED
6-p
SEE 7-p-3 FOR GSKY
CORNER PANEL
DETAIL
SEE 7-p-2 FOR GSKY
CORNER TRIM
DETAIL
SEE 7-p-4 FOR
GUTTER OVER
OPENING
11 7/8" TYP. 6 3/4"
6 3/
4"
CORNER TRIM
MOUNTING
BRACKET 3' O/C
STAINLESS OR
ALUMINUM GSKY
CORNER TRIM
5"
11 7/8" TYP. 5"
5"
GSKY CORNER
PANEL
GSKY CORNER
PANEL MOUNTING
BRACKET
STAINLESS OR ALUMINUM
GSKY GUTTER DRAIN
OVER OPENING
DRAIN PIPE TO DIRECT
WATER FROM GUTTER TO
MAIN DRAINAGE (RUN
DRAIN PIPE IN SIDE TRIM) SEE 8-p FOR MIN WIDTH
LINE OF SIDE TRIM
(TRIM WIDTH CAN
MATCH WITH WITH
GUTTER WIDTH)
4"
1
3D VIEW FOR TYPICAL DETAILS
SCALE NTS (FILE # 7-p-1)
2
PLAN DETAIL / CORNER TRIM
SCALE 1" - 1'-0" (FILE # 7-p-2)
#704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com
DRAWING #
DRAWING TITLE:
GSKY GREEN WALL PANELS
DATE:
REV DATE:
SCALE:AUG 18, 2010
N/A PAPER SIZE: 11 x 17
3D VIEW
CORNER TRIM
CORNER PANEL
GUTTER OVER OPENING
TYPICAL DETAILS / INTERIOR OR EXTERIOR
AS NOTED
7-p
3
PLAN DETAIL / CORNER PANEL
SCALE 1" - 1'-0" (FILE # 7-p-3)
4
SECTION DETAIL / GUTTER OVER OPENING
SCALE 1" - 1'-0" (FILE # 7-p-4)
4"
SEE TABLE FOR MIN WIDTH
STAINLESS OR
ALUMINUM GUTTER
DRAIN
2" DRAIN PIPE WITH
SCREEN COVER
STRIP OF MEMBRANE
OVER GUTTER
SEE TABLE FOR MIN WIDTH
WATERPROOFING
MIN
6"
DRAIN AREA WITH
GRAVEL
HARD SURFACE FOR
MAINTENANCE WITH LIFT
PERFORATED
DRAINAGE PIPE
SEE TABLE FOR MIN WIDTH
DRAIN AREA WITH
GRAVEL
2" DRAIN PIPE WITH
SCREEN COVER
FINISHED CURB
AROUND DRAIN AREA
WATERPROOFING
MIN
6"
± 6"
SEE TABLE FOR MIN WIDTH
METAL GRATING COVER
TRENCH DRAIN AREA
2" DRAIN PIPE WITH
SCREEN COVER
SLOPED FLOOR FINISH
WATERPROOFING
1
SECTION DETAIL / GUTTER DRAIN
SCALE 1" - 1'-0" (FILE # 8-p-1)
GUTTER DRAIN
HEIGHT: LESS THAN 16 PANELS HEIGHT: BETWEEN 16 AND 24 PANELS
TRENCH DRAIN
GROUND DRAIN
CURB DRAIN
MIN 12" NOT ADEQUATE
MIN 24"
MIN 36" (ASK GSKY)
MIN 12"
*DRAIN AREA SHOULD EXTEND MIN 1/2 DRAIN WIDTH FROM EACH SIDES OF GREEN WALL
*MIN WIDTH MAY CHANGE DEPENDING ON PLANT SELECTION
*WATERPROOFING IN TRENCH AND CURB DRAIN ARE REQUIRED
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
HEIGHT: MORE THAN 24 PANELS
NOT ADEQUATE
MIN 24"
MIN 36" (ASK GSKY)
MIN 12"
MIN 24"
MIN 36" (ASK GSKY)
MIN 12"
#704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com
DRAWING #
DRAWING TITLE:
GSKY GREEN WALL PANELS
DATE:
REV DATE:
SCALE:AUG 18, 2010
N/A PAPER SIZE: 11 x 17
GUTTER DRAIN
GRAVEL DRAIN
TRENCH DRAIN
CURB DRAIN
DRAIN DETAILS / INTERIOR OR EXTERIOR
AS NOTED
8-p
2
SECTION DETAIL / TRENCH DRAIN
SCALE 1" - 1'-0" (FILE # 8-p-2)
3
SECTION DETAIL / GRAVEL DRAIN
SCALE 1" - 1'-0" (FILE # 8-p-3)
4
SECTION DETAIL / CURB DRAIN
SCALE 1" - 1'-0" (FILE # 8-p-4)
*REQUIREMENTS:
*ICU - 48"h x 24"w x 36"d (INCLUDING DOOR SWING)
*CONTROLLER - 13"h x 15"w x 20"d (INCLUDING DOOR SWING)
*EASY ACCESS FOR MAINTENANCE
*ADEQUATE PRESSURE TO GET MIN PSI AT BOTTOM OF GREEN WALL (TYP
65 PSI, UP TO 50 FT HEIGHT WALL)
INSTALL BOOSTER PUMP IF REQUIRED (BY PLUMBER)
*120V / 2 AMP POWER (HARD WIRE) (BY ELECTRICIAN)
*DEDICATED TELEPHONE LINE RJ 11 (FOR OTHERS)
*GROUNDING CONNECTION IF REQUIRED (BY ELECTRICIAN)
*1 1/4" CONDUIT BETWEEN ACC AND EACH TRIM SPACES FOR ZONE VALVE
CONTROL WIRES AND FREEZING SENSOR (BY ELECTRICIAN)
*BACK-FLOW PREVENTOR AS REQUIRED (BY PLUMBER)
*GREEN WALL MUST BE DESIGNED TO HAVE SPACE FOR ZONE VALVES TO
RUN ALONG THE SIDE OF THE GREEN WALL WITHIN THE SIDE TRIM (MIN 7"
WIDE TRIM) OR ABOVE THE WALL IN THE TOP TRIM (MIN 8" HIGH TRIM)
*NON-FREEZING INDOOR SPACE WITH FLOOR DRAIN
CONTROLLER / TIMER
HARD WIRE CONNECTION
120 VAC / 2 AMP IN CONDUIT
BY ELECTRICIAN
DEDICATED TELEPHONE LINE
WITH RJ 11 CONNECTION BY
ELECTRICIAN
CONDUIT WITH 16 GA SOLID
COPPER MULTI-STRAND
CABLE BY OTHERS
(# OF WIRES DETERMINED BY
# OF IRRIGATION ZONES AND
SENSORS ON THE WALL)
PRESSURE REGULATION
VALVE
FERTILIZER INJECTOR
FERTILIZER TANK
1" IRRIGATION MAIN LINE
INLET (SIZE MAY VARY)
2'1'-3"
1'-1
"
4'
1" CONDUIT BY G-SKY
FLOW SENSOR
REQUIRES MIN. 1' STRAIGHT
PIPE BEFORE AND AFTER
THE SENSOR
CONTROLLER / TIMER
HARD WIRE CONNECTION
120 VAC / 2 AMP IN CONDUIT
BY ELECTRICIAN
DEDICATED TELEPHONE LINE
WITH RJ 11 CONNECTION BY
ELECTRICIAN
PRESSURE REGULATION
VALVE
FERTILIZER INJECTOR
FERTILIZER TANK
1" IRRIGATION MAIN LINE
INLET (SIZE MAY VARY)
3'1'-3"
1'-1
"
4'
1" CONDUIT BY G-SKY
DEDICATED IRRIGATION ZONE
SUPPLY LINES FROM ICU TO
GREEN WALL BY OTHERS
3/4" FIPT STUB-OUTS ARE
REQUIRED; 1" SUPPLY LINE
MAY BE USED TO KEEP FLOW
TO STUB-OUT
FLOW SENSOR
REQUIRES MIN. 1'
STRAIGHT PIPE BEFORE
AND AFTER THE SENSOR
MASTER VALVE
GRAVITY DRAIN VALVE FOR
AUTOMATED WINTERIZATION
*REQUIREMENTS:
*ICU - 48"h x 36"w x 48"d (INCLUDING DOOR SWING)
*CONTROLLER - 13"h x 15"w x 20"d (INCLUDING DOOR SWING)
*EASY ACCESS FOR MAINTENANCE
*ADEQUATE PRESSURE TO GET MIN PSI AT BOTTOM OF GREEN WALL (TYP
65 PSI, UP TO 50 FT HEIGHT WALL)
INSTALL BOOSTER PUMP IF REQUIRED (BY PLUMBER)
*120V / 2 AMP POWER (HARD WIRE) (BY ELECTRICIAN)
*DEDICATED TELEPHONE LINE RJ 11 (BY OTHERS)
*GROUNDING CONNECTION IF REQUIRED (BY ELECTRICIAN)
*BACK-FLOW PREVENTOR AS REQUIRED (BY PLUMBER)
*CAN BE EXPANDED MAX 6 ZONES TO ACCOMMODATE IF THERE IS NO
SPACE FOR VALVES AT THE GREEN WALL(S)
*NON-FREEZING INDOOR SPACE WITH FLOOR DRAIN
*CAN BE LOCATED OUTDOORS WITH ADDITIONAL ENCLOSURE
*CAN BE CUSTOM DESIGNED TO ACCOMMODATE FREEZING CLIMATES
ICU-600
IRRIGATION CONTROL UNIT FOR:
*GREEN WALLS SMALLER THAN 1080 SQFT (INTERIOR OR EXTERIOR)
*EXTERIOR WALLS IN USDA PLANT ZONE 9 OR HIGHER (NON-FREEZING
CLIMATES)
ICU-1000
IRRIGATION CONTROL UNIT FOR:
*GREEN WALLS LARGER THAN 1080SQFT (INTERIOR OR EXTERIOR)
*EXTERIOR GREEN WALLS IN FREEZING CLIMATES USDA PLANT
ZONE 8 OR BELOW (USDA PLANT ZONE 8 = MAX 20F OR -6.7C)
DEDICATED IRRIGATION ZONE
SUPPLY LINES FROM ICU TO
GREEN WALL BY OTHERS
1" FIPT STUB-OUTS ARE REQUIRED
1
ICU-1000 / ZONE VALVES AT GREEN WAL
SCALE 3/4" - 1'-0" (FILE # 9-p-1)
2
ICU-600 / ZONE VALVES AT ICU
SCALE 3/4" - 1'-0" (FILE # 9-p-2)
#704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com
DRAWING #
DRAWING TITLE:
GSKY GREEN WALL PANELS
DATE:
REV DATE:
SCALE:AUG 18, 2010
N/A PAPER SIZE: 11 x 17
ICU-1000
ICU-600
PLUMBING REQUIREMENTS
ELECTRICAL REQUIREMENTS
IRRIGATION CONTROL UNIT (ICU) DESIGNS
AS NOTED
9-p
3/4" FIPT IRRIGATION
STU-OUT BY OTHERS
SEE DRAWING #1 FOR
STUB-OUT LOCATIONS
1 1/2"
4"
MAX
2"
S
S
S S
MAX 36 PANELS IN SINGLE ROW
MAX
5 P
ANEL
S HE
IGHT
IN S
INGL
E ZO
NE
CAN BE IN SAME ZONE IF 3 OUT
OF 5 ROWS IN SINGLE ZONE
ARE CONTIUOUS
IF MORE THAN 3 OUT 5 ROWS
ARE TERMINATED BY OPENING,
REQUIRE ANOTHER STUB-OUT
3/4" STUB-OUT WITH FIPT
CONNECTION (MAIN LINE
MAY BE 1" TO KEEP FLOW)
S
MAX 36 PANELS IN SINGLE ROW
MAX
5 P
ANEL
S HE
IGHT
IN S
INGL
E ZO
NE
Z Z Z Z
LOCATE ZONE VALVES WITH IN
TOP TRIM SPACE; MIN 8" TOP TRIM
SPACE IS REQUIRED
SINGLE IRRIGATION STUB-OUT
AND CONDUIT FOR ICU-1000; SEE
9-p FOR REQUIREMENTS
C
F
INSTALL FREEZING AND REV
FREEZING SENSOR FOR
FREEZING REGION
D
D
D
D
LOCATE DRAIN VALVES AT
BOTTOM OF EACH ZONE FOR
FREEZING REGION
6 1/2"
8"
1" IRRIGATION
SUPPLY LINE FROM
STUB-OUT
CONTROL WIRES
(FREE WIRED OR IN
CONDUIT)
ZONE VALVES
GSKY TOP TRIM
MAX. 36 PANELS IN EACH CONTINUOUS ROW
MAX. 5 PANELS HEIGHT IN ONE ZONE
MAIN IRRIGATION SUPPLY LINE CAN BE COPPER, PEX OR PVC TO MEET
LOCAL CODE (BY PLUMBER)
STUB-OUT SHOULD BE INSTALLED WITH FEMALE PIPE THREAD FITTINGS
1
IRRIGATION LAYOUT FOR ICU-600 / ZONE VALVES AT ICU
SCALE NTS (FILE # 10-p-1)
2
IRRIGATION STUB-OUT DETAIL FOR ICU-600
SCALE 1-1/2" = 1'-0" (FILE # 10-p-2)
3
IRRIGATION LAYOUT FOR ICU-1000 / ZONE VALVES IN TOP TRIM
SCALE NTS (FILE # 10-p-3)
#704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com
DRAWING #
DRAWING TITLE:
GSKY GREEN WALL PANELS
DATE:
REV DATE:
SCALE:AUG 18, 2010
N/A PAPER SIZE: 11 x 17
IRRIGATION LAYOUT FOR ICU-1000
IRRIGATION LAYOUT FOR ICU-600
STUB-OUT DETAIL
ZONE VALVE DETAIL
IRRIGATION LAYOUT 1
AS NOTED
10-p
4
ZONE VALVE DETAIL FOR ICU-1000 IN TOP TRIM
SCALE 1-1/2" = 1'-0" (FILE # 10-p-4)
1" IRRIGATION
SUPPLY LINE FROM
STUB-OUT
CONTROL WIRES
(FREE WIRED OR IN
CONDUIT)
ZONE VALVES
GSKY TOP TRIM
6"
7"
6 1/
2"
S
MAX 36 PANELS IN SINGLE ROW
MAX
5 P
ANEL
S HE
IGHT
IN S
INGL
E ZO
NE
C
Z
Z
Z
Z
Z
Z
SINGLE IRRIGATION STUB-OUT
AND CONDUIT FOR ICU-1000; SEE
8-p FOR REQUIREMENTS
LOCATE ZONE VALVES WITH IN
SIDE TRIM SPACE; MIN 6" SIDE
TRIM SPACE IS REQUIRED
MAX
50
PAN
ELS
HEIG
HT
INSTALL FREEZING AND REV
FREEZING SENSOR FOR
FREEZING REGION
F
D
D
D
D
D
D
LOCATE DRAIN VALVES AT
BOTTOM OF EACH ZONE FOR
FREEZING REGION
MAX. 36 PANELS IN EACH CONTINUOUS ROW
MAX. 5 PANELS HEIGHT IN ONE ZONE
MAIN IRRIGATION SUPPLY LINE CAN BE COPPER, PEX OR PVC TO MEET
LOCAL CODE (BY PLUMBER)
STUB-OUT SHOULD BE INSTALLED WITH FEMALE PIPE THREAD FITTINGS
#704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com
DRAWING #
DRAWING TITLE:
GSKY GREEN WALL PANELS
DATE:
REV DATE:
SCALE:AUG 18, 2010
N/A PAPER SIZE: 11 x 17
IRRIGATION LAYOUT FOR ICU-1000
ZONE VALVE DETAIL
-
-
IRRIGATION LAYOUT 2
AS NOTED
11-p
1
IRRIGATION LAYOUT FOR ICU-1000 / ZONE VALVES IN SIDE TRIM
SCALE NTS (FILE # 11-p-1)
2
ZONE VALVE DETAIL FOR ICU-1000 IN TOP TRIM
SCALE 1-1/2" = 1'-0" (FILE # 11-p-2)