DISCLAIMERThis installation guide is only to be used in conjunction with panel installation drawings and PermaTherm recommended details. Details shown in the projects shop drawings take precedence over any similar information in this guideline.
Shop drawings may be prepared by your design engineer or the panel contractor. If you need a recommendation for a design engineer, call PermaTherm customer ser-vice. 706-468-7500
This guide is intended to provide the panel installer with recommended methods, procedures and guidelines for the installation of PermaTherm wall and ceiling panels for commercial and industrial cold storage applications. Information presented is ac-curate but may not cover all situations, building conditions and details of your specific project. Consult the design engineer if this guide does not cover your construction requirements. It is the responsibility of the project engineer and panel installer to en-sure specified air tightness of a building using approved drawings and the appropriate type of sealants. It is the sole responsibility of the owner’s panel installer to maintain quality workmanship in accordance with approved shop drawings to ensure the best performance of the wall and ceiling system. PermaTherm recommends installers read this document fully before ordering and receiving panels.
Follow the architect’s approved shop drawings and engineering calculations for your project specific fastening patterns. The engineer of record is responsible for verifying applicable design loads and panel fastening requirements.
We are glad you have chosen PermaTherm panels for your new project. Your building is very important to us and this is why we, at PermaTherm, suggest that only experi-enced panel installers complete the installation. While PermaTherm panels are easy to install, there are certain “tricks of the trade” that only an experienced installer will identify with. If our 25+ years of experience in the cold storage warehouse business have taught us one thing it is that any panels are only as good as the design engineer and panel installer. Choose wisely. You may spend a few more pennies on the front end, but you will save many dollars in the long run.
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 3
INTRODUCTION Thank you for choosing PermaTherm insulated metal panels. PermaTherm has been manufacturing insulated metal panels for the cold storage industry for over 25 years. Our unique approach to help you and your team construct the best building possible is the cornerstone of what we are about. We manufacture high quality EPS panels for cold storage that meet strict guidelines for quality and function.
These are just a few of the benefits of using PermaTherm panels for your project.1. LTTR (long term thermal resistance) R-values as high as 60 R. without any
degradation of R value over time.2. PermaTherm has the strongest insulated metal panel on the market today.
No panel is stronger than our wall and ceiling panels. Greater spans can cut down on red steel requirements.
3. Easy tongue and groove design allows you to construct easily and efficiently.4. PermaTherm panels are available in different textures, profiles and colors.5. Large job or small job, you will get the same attention to detail from our Per-
maTherm team.6. We also produce all of the trim and accessories that you will need to complete
your job. One call gets you everything you need to complete your project.7. Available from 2” thick up to 12” thick. Lengths up to 60 feet.8. PermaTherm panels are warranted for one full year from the date of purchase.9. Short lead times for delivery. In most instances Permathrm can deliver panels
in 3 to 4 weeks.
Why would you use anyone else?
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 4
DELIVERY AND INSPECTION OF YOUR PERMATHERM PANELS
Panels are carefully packaged in large shrink-wrapped bundles, then shipped on flat bed trailers to the construction site. When a shipment is received, check all items against the shipping document for quantities, dimensions, colors, transit damages, etc. Document any shortage of panels and accessories or panel damage on the bill of lading and have it signed by the driver. It is the receiver’s responsibility to make any damage claims immediately. Please note that although every effort is made to preventshipping damage, PermaTherm is not responsible for damage which may occur during transportation, delivery, storage or on-site handling. Damages must be handled be-tween the receiver and the transportation company. The transportation company may send a representative to inspect damage for your claim.
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 5
MATERIAL HANDLING AND STORAGE OF PERMATHERM INSULATED METAL PANELS
The recommended loading/unloading method for bundles less than or equal to 30’ is to use a single forklift with widely spaced forks placed under the center of the bundle.
Panel bundles over 30’ in length may be moved by using two forklifts spaced equally along the length of the bundle. Forks must not extend beyond the width of the pan-els. Fork length needs to be 46 inches to unload. If the forks are longer than 46 use a buffer so as to not allow the forks to extend beyond the width edge of the panels.
PANEL STORAGESite must have adequate storage space to receive and store the panel bundles. This space must be level, firm, clean and free from standing water. Bundles should be stored in a dry condition, with one end slightly elevated to facilitate moisture drainage.
Panels should be inspected upon delivery for presence of moisture. If moisture is pres-ent, bundles should be slit open immediately to allow ventilation and drainage.
Panels in opened bundles should be covered by a plastic sheet or tarp at the end of the working day.
The covering and bundles must be securely fastened to prevent wind damage.
If panels are not to be used immediately, then they should be stored under a tempo-rary shelter with the plastic removed from the top and sides of the bundles. Recover the bundles with a protective tarp and adequately secure both tarp and panels to prevent wind damage.
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 6
MATERIAL HANDLING AND STORAGE OF PERMATHERM INSULATED METAL PANELS
PermaTherm panels have been thoroughly evaluated and tested by independentthird party laboratories to determine all aspects of their performance. The results of these tests, in combination with our comprehensive engineering analysis, enable us to provide design assistance for nearly every project. This includes complete panel analysis of wind, live and thermal loading as well as allowable deflection, fastening and spans.
Current International Building Codes specify wall cladding panels to be designed for a de-flection of L/180. The project designer and/or engineer of re-cord should always check the applicable code(s) for deflec-tion limits. For deflection limits other than L/180, please con-tact PermaTherm’s Technical Services for evaluation.
Insulated panels should not be relied upon to provide significant diaphragm strength. Instead, cross bracing (cables, rods, angle iron etc.) should be used to provide dia-phragm. Insufficient bracing for the walls may result in damage to the panels, and will void the panel warranty.
For more information on any of the above items, please contact PermaTherm’s Customer Service:
706-468-7500The information contained in this guide is thought to be reliable and correct, but is subject to change without notice.
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 7
CUTTING OF PERMATHERM INSULATED METAL PANELS
Personnel working with panel cutting equipment should wear respiratory and eye protection at all times.
Panel cutting should take place prior to panel installation whenever possible. Use the appropriate cutting tools with extreme care to avoid panel delamination. Do not use a cutting disk, torch, and other high heat producing methods for cutting. Hot filings may damage the painted surface of the panel. PermaTherm recommends using a circular saw with a fine-tooth carbide tip blade or PermaTherm’s supplied beater blade, which was made specifically for metal panels. Power snips, nibblers or hand snips may be used to cut trims and flashings.
Milwaukee’s 8” Metal Cutting Circular Saw 6370-20 series shears the metal, produc-ing a virtually spark-free wake and cool, burr and scorch-free edges that don’t require post-cut finishing. Cool cut waste, in the form of metal shavings, is effectively con-tained with a durable magnesium blade shield and channeled into the saw’s integral Chip Tank. Cool cutting also means that materials can be handled almost immediately following a cut, reducing downtime.
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 8
DETAIL: No. 3001Z-Lock Joint System
Detail - Interior Joint Inside
(no caulk on inside)
Z-Lock Joint System
Detail - Exterior Joint
Caulk On Outside OnlyFSI-96 Non skinning Butyl Cauk
This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.
Side View
3/8” bead of caulk is required
269 Industrial Park RoadMonticello, GA 31064
Outside
Inside
Contents and logo are property of PermaTherm, Inc.All rights reserved. Copyright 2019 ©
PERMATHERM INSULATED METAL PANEL SEALANT
Where to caulk1. Female edge of panels: one 3/8”
bead on the inside of the female leg of the panel and one 3/8” bead in the middle of panel.
2. Place two 3/8” beads of caulk on floor on bottom side of panel.
3. All trim on the warm side inside attachment screws.
4. Two 3/8” beads of caulk on all ceiling to wall connections.
See Panel detail for exact location of caulk. Caulk is one of the most important parts of every panel job. Lines must be continues and full 3/8” bead. A break in caulk can cause vapor leaks.
Permatherm’s recommended sealant is our FSI-96 Non Skinning Butyl caulk.
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 9
Floor Wall Intersection C
FSI-96 Non Skinning Butyl Caulk
1/4” - 14 x 7/8” Tek 112” on center
DETAIL: No. 6121Floor Wall Intersection C
WallPanel
Perimeter Base Flashing
Vapor Barrier Flashing
Concrete Floor
Concrete Anchor
Side View
This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.
Silicone or UrethaneSealant
269 Industrial Park RoadMonticello, GA 31064
Contents and logo are property of PermaTherm, Inc.All rights reserved. Copyright 2018 ©
Floor Wall Intersection C
Place base track onto floor with non-skinning butyl caulk on each edge under base track. Secure base track with 3/8” X 4” anchor bolts. Place a thermal cut on the inside of the panel 4” from the bottom. Cut should only cut through the metal skin of the panel 1/4” deep. Place non-skinning butyl caulk inside base track per detail.
Place the panel into base track and secure with ¼” - 14 HWH #5 pt. self-drilling screws at recommended connection points. Con-crete is to be poured per in-dustry specs for cooler ap-plication by your approved concrete contractor.
If using a non stepdown design, use same directions on top of flat concrete floor.
PERMATHERM INSULATED METAL PANEL INSTALLATION FOR GROW ROOMS
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 10
18 ga or 16 ga Base channel
Permatherm InsulatedWall panel
FSI-96 Non Skinning Butyl Caulk
FSI-96 Non Skinning Butyl Caulk
1/4” - 14 x 7/8” Tek 112” on center
1/4” - 14 x 7/8” Tek 112” on center
DETAIL: No. 3008Exterior Perimeter Base Flashing
Side View
Anchor Bolt
This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.
269 Industrial Park RoadMonticello, GA 31064
Contents and logo are property of PermaTherm, Inc.All rights reserved. Copyright 2018 ©
Floor Wall Intersection D
Floor Wall Intersection D
Place base track onto floor with non-skinning butyl caulk on each edge under base track. Secure base track with 3/8” X 4” anchor bolts. Place a thermal cut on the inside of the panel 4” from the bottom. Cut should only cut through the metal skin of the panel 1/4” deep. Place non-skinning butyl caulk inside base track per detail.
Place the panel into base track and secure with ¼” - 14 HWH #5 pt. self-drilling screws at recommended connection points. Con-crete is to be poured per in-dustry specs for cooler ap-plication by your approved concrete contractor.
PERMATHERM INSULATED METAL PANEL INSTALLATION FOR GROW ROOMS
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 11
Wall Details: Interior wall to exterior wall juncture for a Grow Rooms.
We will cover several wall details and intersections. You may have a situation that calls for another detail that is not covered. Give our technical team a call and we can help you with your unique need. 706-468-7500
This depicts a divider wall between two areas against an outside wall.
Secure the wall into base track. Make sure panels are level and plum with the outside wall. If a gap exists, use PermaTherm’s foam fill spray in urethane foam insulation to fill in gap.
Place 2 X 2 inside angle trim onto walls at corner intersection.
Secure with ¼”-14 HWH #5 pt. selfdrilling screws 8” apart.
Interior Wall toExterior Wall Juncture
Cold
1/4” Field cut Thermal Break inMetal Skin (if needed)
1/4” - 14 x 7/8” Tek 1 12” on center (typical)
DETAIL: No. 3002Interior Wall to Exterior Wall-Cold
Inside
Inside
26 gauge Interior Trim Angle Fasciato match panel skin
Top View
This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.
1/4”-14 X 78” Tek 1
Ou
tsid
e
269 Industrial Park RoadMonticello, GA 31064
Contents and logo are property of PermaTherm, Inc.All rights reserved. Copyright 2018 ©
PERMATHERM INSULATED METAL PANEL INSTALLATION FOR GROW ROOMS
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 12
Wall Details: Grow Room Corner Detail
We will cover several wall details and intersections. You may have a situation that calls for another detail that is not covered. Give our technical team a call and we can help you with your unique need. 706-468-7500
Place the corner panel in the caulked base track and secure with 1/4”-14 tek screw at each edge and 8” on center.
Place the intersecting panel against the wall panel. Place caulk on the panel face toward the outside of the wall panel as illistrated. Make sure the panel is level and butts up secure against the adjacent wall panel. If a gap exists, use the PermaTherm ure-thane spray foam to seal any gaps. Clean outside edges and place the PermaTherm Peal & Seal tape over the two panel edges as illustrated.
Caulk as illustrated and place the out-side angle trim onto the outside and secure with the 1/4”-14 tek screws at each edge and 8” apart. On the in-side check for gaps and if any exists,
fill with PermaTherm’s urethane spray to seal. Place the inside angle on the inside corner and secure using the 1/4”-14 tek screws at each edge and 8” apart.
FSI-96 Non skinning Butyl Caulk
26 Gauge Exterior Corner FlashingTo match panel skin
Permatherm Peal & Seal Tape
Grow Room Corner Detail
26 gauge inside angle to match panel skin
1/4” - 14 x 7/8” Tek 112” on center
DETAIL: No. 4911Ceiling to Wall Detail
1/4” - 14 X 7/8” Tek 112” on center
Top View
1/4” Field cut Thermal Break
This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.
Wall panel
269 Industrial Park RoadMonticello, GA 31064
Wall Panel
Contents and logo are property of PermaTherm, Inc.All rights reserved. Copyright 2019 ©
PERMATHERM INSULATED METAL PANEL INSTALLATION FOR GROW ROOMS
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 13
Ceiling to Wall Detail
We will cover several wall details and intersections. You may have a situation that calls for another detail that is not covered. Give our technical team a call and we can helpyou with your unique need. 706-468-7500
Once walls are up and secure, place a bead of caulk on top of the outer part of the wall as illustrated. Place the ceiling panel on top of the wall panel even with the outside.
Once it is secured use 2 X 2 inside angle onto the inside corner juncture of the panel and secure with tek screws at each edge and every 8” along the length of the wall/ceiling.
Place a bead of caulk on the inside of the outside angle piece at the top and on the side per illustration. Secure with tek screws at each edge and every 8” along the length of the wall/ceiling.
FSI-96 Non skinning Butyl Caulk
26 Gauge Exterior Corner FlashingTo match panel skin
Permatherm Vapor Barrier Tape
Ceiling to Wall Detail
26 gauge inside angle to match panel skin
1/4” - 14 x 7/8” Tek 112” on center
DETAIL: No. 4911Ceiling to Wall Detail
1/4” - 14 X 7/8” Tek 112” on center
Side View
1/4” Field cut Thermal Break
This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.
Ceiling panel
Wall panel
269 Industrial Park RoadMonticello, GA 31064
Contents and logo are property of PermaTherm, Inc.All rights reserved. Copyright 2018 ©
PERMATHERM INSULATED METAL PANELINSTALLATION FOR GROW ROOMS
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 14
Partition Wall to Ceiling Panel
We will cover several wall details and intersections. You may have a situation that calls for another detail that is not covered. Give our technical team a call and we can help you with your unique need: 706-468-7500.
When there is a juncture on top of a divider wall place each panel halfway onto wall butting them up firmly together.
Place PermaTherm’s Peel & Seal vapor tape over joint on topof panels.
Place 4” wide flat batten down with two beads of 3/8” caulk one just inside each tek screw as shown in detail drawing. Secure batten with tek screws at each edge and 8” apart on each side of the batten. Place the 2 X 2 inside angle onto the inside corner junctures securing them with tek screws at each edge and every 8”. Place PermaTherm’s Peal & Seal vapor tape on all joints on the top side of the ceiling.
Partition Wall to Ceiling Panel
FSI-96 Non skinning Butyl Caulk
FSI-96 Non Skinning Butyl Caulk
4” Wide 26ga Flat batten
Permatherm’s Peel & Seal vapor tape
1/4” - 14 x 7/8” Tek 112” on center
DETAIL: No.3006Partition Wall to Ceiling Panel
Ceiling PanelCeiling Panel
Wal
l Pan
el
Outside
InsideInside
This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.
Side View
269 Insustrial Park RoadMonticello, GA 31064
Contents and logo are property of PermaTherm, Inc.All rights reserved. Copyright 2019 ©
PERMATHERM INSULATED METAL PANEL INSTALLATION FOR GROW ROOMS
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 15
Wall Details: Girt Attachment A for attachment to Steel Girts
We will cover several wall details and intersections. You may have a situation that calls for another detail that is not covered. Give our technical team a call and we can help you with your unique need. 706-468-7500
This girt attachment is for H beamtype girts. Place 10ga Steel Spline Plate into panels spline groove centered on girt. Using the appro-priate length self drilling screw to attach off-set clip per detail draw-ing.
(Note: Place a thermal cut above the-mid girt across entire length of wall to prevent thermal bowing on outside walls. Contact your design engineer to determine if more than one thermal bowing cut is needed)
Girt Attachment Detail A
Offset Girt Clip
Mid Girt
10ga Steel Spline Plate
DETAIL: No. 1155Girt Attachment Detail “A”
This detail is commonly used for this application; however, every building project is different. You should consult your building engineer to make sure thisdetail will work for your particular application.
Side View
Thermal Cut for outside wallsto prevent thermal bowing.
OutsideInside
269 Industrial Park RoadMonticello, GA 31064
Contents and logo are property of PermaTherm, Inc.All rights reserved. Copyright 2018 ©
PERMATHERM INSULATED METAL PANEL INSTALLATION FOR GROW ROOMS
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 16
Wall Details: Girt Attachment B for attachment to Steel Girts
We will cover several wall details and intersections. You may have a situation that calls for another detail that is not covered. Give our technical team a call and we can help you with your unique need. 706-468-7500
Place 10ga Steel Spline Plate into panels spline groove centered on girt. Using the appropriate length self drilling screw to attach off-set clip per detail drawing.
(Note: Place a thermal cut above the mid girt across entire length of wall to prevent thermal bowing on outside walls. Contact your design engineer to determine if more than one thermal bowing cut is needed)
Girt Attachment Detail B
Offset Girt Clip
Mid Girt
10ga Steel Spline Plate
DETAIL: No. 1188Girt Attachment Detail “B”
Side View
This detail is commonly use for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.
Thermal Cut for outside walls to prevent thermal bowing
Outside Inside
269 Industrial Park RoadMonticello, GA 31064
Contents and logo are property of PermaTherm, Inc.All rights reserved. Copyright 2018 ©
PERMATHERM INSULATED METAL PANEL INSTALLATION FOR GROW ROOMS
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 17
Wall Details: Girt Attachment C for attachment to Steel Girts
We will cover several wall details and intersections. You may have a situation that calls for another detail that is not covered. Give our technical team a call and we can help you with your unique need. 706-468-7500
Place 10ga Steel Spline Plate into panels spline groove centered on girt. Using the appropriate length self drilling screw through girt into 10 gauge spline per detail draw-ing.
(Note: Place a thermal cut above the mid girt across entire length of wall to prevent thermal bowing on out-side walls. Contact your design en-gineer to determine if more than one thermal bowing cut is needed)
Girt Attachment Detail C
10ga Steel Spline Plate
DETAIL: No. 1188Girt Attachment Detail “C”
Side View
This detail is commonly use for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.
Thermal Cut for outside walls to prevent thermal bowing
Outside Inside
Girt
269 Industrial Park RoadMonticello, GA 31064
Contents and logo are property of PermaTherm, Inc.All rights reserved. Copyright 2018 ©
PERMATHERM INSULATED METAL PANEL INSTALLATION FOR GROW ROOMS
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 18
Ceiling Channel Suspended Ceilings
We will cover several wall details and intersections. You may have a situation that calls for another detail that is not covered. Give our technical team a call and we can help you with your unique need. 706-468-7500
Measure distance for threaded rod to make sure ceiling panels are lev-el and plumb. Place threaded rod through center of open web truss or drill through truss and attach wash-ers and nuts. Place panels onto channel and secure onto bottom of ceiling panels with tek screws ev-ery 12” and at each edge. On top of ceiling using PermaTherm’s foam fill, fill the void between the panels with the urethane foam fill all the way up to the top of the panel. Wipe off any excess urethane and clean surface. Place PermaTherm’s Peel & Seal vapor tape over the filled gap in the panels. Place the metal batten down on top of the tape with 2 beads of 3/8” caulk inside each tek screw and secure at edges and 8” apart. Place PermaTherm’s pipe caulk onto Per-maTherm’s threaded rod wrap insu-lation edges and bottom. Place over
the threaded rod and use the self-sealing lap secure the insulation over the threaded rod. Caulk the top of the insulation where the rod comes out of the insulation per de-tails. Place the 26 gauge metal cover cap over the channel housing and secure with tek screws at each edge and 8” apart. Use a clear or white silicone caulk at each edge of the cover cap per detail drawing.
CEILING PANEL
4"WIDE 26ga. Flat Batten
Clear or WhiteSilicone Caulk
Fill Void with Permatherm Foam Pack
Clear or White Silicone Caulk
Ceiling Channel Suspended Ceiling
FSI-96 Non Skinning Butyl Caulk
Bottom Chord of Open Web Truss System( Provided by other)
Metal Cover Cap 26 Gauge
6” Wide 16 Gauge Galvanized Channel
WasherNut
3/8” Nuts(provided by other)
3”x3” Washer 10 Ga( Provided by other)
Permatherm 3/8” X 4” X 36” 2 Lbs. Threaded Rod Insulation to prevent frost build up
FSI-96 Non Skinning Butyl Caulk
3/8” Threaded Rod
1/4” - 14 x 7/8” Tek 112” spacing
DETAIL: No. 3007Ceiling Channel Suspended Ceiling
CEILING PANEL
Side View
OutsideOutside
Inside
This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.
269 Industrial Park RoadMonticello, GA 31064
FSI-96 Non SkinningButyl Caulk
1/4”-14 X 7/8” Tek 112” SpacingPermatherm’sPeel & Seal Vapor Tape
For greater span strength on a suspended Ceiling
Contents and logo are property of PermaTherm, Inc.All rights reserved. Copyright 2019 ©
PERMATHERM INSULATED METAL PANEL INSTALLATION FOR GROW ROOMS
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 19
Rod Eye Suspended Ceiling
We will cover several wall details and intersections. You may have a situation that calls for another detail that is not covered. Give our technical team a call and we can help you with your unique need. 706-468-7500
Measure distance for threaded rod to make sure ceiling panels are level and plumb. Place threaded rod through center of open web truss or drill through truss and attach washers and nuts. Place panels onto channel and secure onto bottom of ceiling panels with tek screws every 12” and at eachedge. On top of the ceiling ,us-ing PermaTherm’s foam fill, fill the void between the panels with the urethane foam fill all the way up to the top of the panel. Wipe off any excess urethane and clean sur-face. Place PermaTherm’s Peel & Seal vapor tape over the filled gap in the panels. Place the metal bat-ten down on top of the tape with 2 beads of 3/8” caulk inside eachtek screw and secure at edges and 12” apart. Place PermaTherm’s pipe caulk onto PermaTherm’s threaded rod wrap insulation edg-
es and bottom. Place over the threaded rod and use the self-sealing lap secure the insulation over the threaded rod. Caulk the top of the insulation where the rod comes out of the top of the insulation per details.
Ceiling Panel Ceiling Panel
T-Bar Suspended Ceiling
FSI-96 Non Skinning Butyl Cauk
FSI-96 Non Skinning Butyl Cauk
All Thread Rod
Permatherm’s 4” X 36” - 2 lbs.Polystyrene Rod Insulation(freezer only)
Permatherm’s Foam Pack UrethaneInsulation
Tee Bar
Rod Eye
1/4” - 14 x 7/8” Tek 18” on center
DETAIL: No. 1119T - Bar Suspended Ceiling
Side View
This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.
Permatherm’sPeel & Seal Vapor Tape
26 Gauge Flat Batten
Permatherm Pipe Caulk
Contents and logo are property of PermaTherm, Inc.All rights reserved. Copyright 2018 ©
OutsideOutside
Inside
PERMATHERM INSULATED METAL PANEL INSTALLATION FOR GROW ROOMS
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 20
Trims:1. Inside angle2. Outside angle3. Flat batten4. Joint Flashing5. Perimeter Base Flashing6. Cap channel
Fasteners:1. 1/4-14 X 7/8” Tek 1 Self Drilling Screw2. 3/8” X 4” anchor bolts3. 1/4-14 X 2” Self drilling Screw4. 3”5. 4”6. 5”7. 6”8. 7”9. 8”
Peal & Seal Vapor Tape 4” 25 mil
Tee Bar 10’ sections of 4” TeeTee Bar clamps with boltsTee Bar eylets with bolts
Channel sections 10’
Threaded Rod 3’, 6’, 8’, 10’
Spray in Urethane foam packs
Off set girt clips
10 gauge splines
Hard Board splines
Beater Blades for cutting metal panels
INSIDE ANGLE OUTSIDE ANGLE
FLAT BATTEN CAP CHANNEL
DRIP EDGE TEE BAR WITH CONNECTOR
10 GAUGE SPINE Z TRIM
HARDBOARD SPLINE
PEEL AND SEAL SEAM TAPE
THREADED ROD
OFF SET CLIPS
LARGE AND SMALL FOAM PACKS
NON SKINNING BUTYL CAULK
SELF DRILLING TEK SCREWS
INSIDE ANGLE WITH 16 GAUGE CORNER
PERMATHERM PANEL ACCESSORIES
Caulk:1. FSI-96 Non Skinning Butyl2. FSI Butyl Caulk for EPS rod
insulation.
WWW.CCROOMS.NETContents and logo are property of PermaTherm, Inc.
All rights reserved. Copyright 2019 ©Page 21