green building performance in australia
DESCRIPTION
Keynote presentation to ARBS conference in Melbourne on 7 May 2012. Topic dealt with actual performance data in green buildings with a focus on Australian building performance.TRANSCRIPT
![Page 1: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/1.jpg)
Jerry YudelsonYudelson Associates
If It Doesn’t Perform, It Can’t Be Green!
![Page 2: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/2.jpg)
Take-AwaysGreen buildings are important for controlling CO2 emissions
Many buildings do not perform as predicted or as needed
Without reporting actual performance, the entire exercise will be wasted
Energy use metrics are well known
![Page 3: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/3.jpg)
8 Testable Propositions
• Green building vital in the global carbon picture• Green building growing rapidly in all sectors• Green building business case is proven• BUT, many green buildings not performing as predicted• Building energy performance reports all vitally needed• Buildings must measure total carbon performance• Zero-net-energy buildings feasible today• Beyond energy, water is the next big issue
![Page 4: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/4.jpg)
Green Building Important for Carbon Reduction
![Page 5: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/5.jpg)
Green Buildings Make Money Sense
![Page 6: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/6.jpg)
Business Case for Green is Proven
Financial/economic return
Risk mitigation
Marketing/public relations
Productivity/health gains
Recruitment/retention
Sustainability concerns
ASU Biodesign Institute B
LEED Platinum
![Page 7: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/7.jpg)
Potential Impact of Rapid Greening
• 14% reduction in CO2, 2025 vs. 2005
• NPV of green building: $650 billion in U.S.– 5x to 10x cost premium
• 2020 Prediction: – Green buildings 95% of new
construction– Green retrofits are 75% of
all retrofits
![Page 8: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/8.jpg)
Green Building Growing Rapidly
![Page 9: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/9.jpg)
Green Building Statistics
30,000+ LEED registered projects (Dec. 2011)
130 countries use LEED
12,000+ LEED certified projects (March 2012)
175,000+ LEED Accredited Professionals
OREGON
HEALTH & SCIENCEUNIVERSITY
“In God We Trust; All Others Must Bring Data.”
-W. Edwards Deming
![Page 10: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/10.jpg)
Building Energy = Carbon Solution
Reducing energy use in buildings is the only Life Cycle Cost-positive carbon mitigation solution25% of total carbon solution can come from buildingsKey issue today is finance, not economics
Choosing GreenChoosing Green
![Page 11: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/11.jpg)
Energy Performance Reports Needed
![Page 12: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/12.jpg)
Performance Reporting Informs
• “What gets measured, gets managed”
• If building energy use is this important to our collective future, why not know what’s going on?
• Without reports, we are flying blind/can’t fix
• Why should governments put their faith in green building without performance reports?
![Page 13: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/13.jpg)
New Green Buildings Under-Performing
![Page 14: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/14.jpg)
Energy Savings in LEED Buildings
![Page 15: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/15.jpg)
What’s the Issue?
• Average savings is 35% vs. standard (Kats)
• BUT, about 25% actually underperform
• One LEED Platinum building:– Modeled at 61% savings– Performs at 48% savings
• Underperforming buildings hurt validity of green building premise
![Page 16: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/16.jpg)
Buildings Must Measure Carbon
![Page 17: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/17.jpg)
Total Carbon Emissions Count
• Total carbon emissions should be the only energy points in green rating schemes; this means:– 80% reductions with new
buildings– 40% in older buildings
• Relative improvement (%) needs to be retired
• Real performance assessment– Buildings will be de-rated
![Page 18: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/18.jpg)
Europe: Measure Total Carbon Emissions
![Page 19: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/19.jpg)
ZerO-Net-Energy Buildings Feasible
![Page 20: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/20.jpg)
Lessons from Lean Manufacturing
• Lean Themes– Boeing 767: $130 million ea.
• Each plane performs identically• Compare with two 350,000-SF buildings
– Reduce energy & water use/carbon footprint
– Eliminate waste– Build in resiliency– Need to make champagne on a beer
budget!• =>Process changes
– Key issue: get green cost premium down to zero, using integrated design process
![Page 21: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/21.jpg)
How Much Energy Should Buildings Use?
• European stretch goal: 100-150 kWh/sqm/a PRIMARY energy use
• U.S. Average: 400 kWh/m2/a (2003)– 50% better than average
still not good enough!– 60% to 90% required– 2030 Challenge
![Page 22: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/22.jpg)
Where Do We Need to Get?
![Page 23: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/23.jpg)
Research: World’s Greenest Buildings
• LEED Platinum (or 6-Star Green Star equivalent)
• Built since 2003• >50,000 sq.ft. (5,000
sqm)• Non-residential• Must provide energy data
for one year• Water data, as available
![Page 24: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/24.jpg)
2 Victoria Avenue, Perth6-Star Green Star – Office As Built
62 kwh/sqm/annum
• Graywater treatment• Active chilled beams• Floor-by-floor air handling
system• Annual operating costs
savings: $85,000• 5 Star NABERS
![Page 25: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/25.jpg)
The Gauge, Melbourne6-Star Green Star – Office As Built
• Blackwater treatment system recycles 96% of wastewater
• Gas-fired cogen plant supplies 25% of energy use
• Individual control of thermal comfort at 90% of stations
• 5 Star NABERS
193 kwh/sqm/annum
![Page 26: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/26.jpg)
Council House 2, Melbourne6-Star Green Star – Office As Built & Design
190 kwh/sqm/annum
• Thermal cooling, night purge, 5 “shower towers”
• 100% fresh air• Solar thermal• PV system @ 3.5-kWh/day• Green roof• Gas cogeneration system• Sewer mining
![Page 27: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/27.jpg)
Workplace 6, Sydney6-Star Green Star – Office As Built
• Blackwater treatment + sewer mining capacity
• Tri-generation plant
• Harbor water heat rejection
• Solar thermal111 kwh/sqm/annum
![Page 28: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/28.jpg)
One Shelley Street, Sydney6-Star Green Star – Office Design
116 kwh/sqm/annum
• Activity Based Working (ABW) design = 20% less space, 35% less paper
• “Diagrid” structure = Flexible interior, 80% daylighting
• Harbor water heat rejection
• Chilled beams• 100% fresh air
![Page 29: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/29.jpg)
Pixel, Melbourne6-Star Green Star – Office Design
• Perfect Green Star Score: 100 + 5 innovation points
• Highest LEED score: 102 of 110 available points
• BREEAM Outstanding• 3 @1.5-kW wind turbines
& 6.5-kW PV• Net-zero water use,
vacuum toilets32 kwh/sqm/annum
![Page 30: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/30.jpg)
One Bligh, Sydney6-Star Green Star - Office As Built
•
106 kwh/sqm/annum
• Blackwater recycling plant for cooling tower makeup
• 65,000-liter rainwater tank• Double-skin glass façade• Tri-generation system: heating,
cooling, electricity generation (vacuum-tube solar collectors)
![Page 31: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/31.jpg)
Asia/Pacific Buildings 6-Star Green Star Equivalent
![Page 32: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/32.jpg)
The Future is Green, But…
If you want to score, run to where the ball is headed, not to where it is.
Ask yourself and your clients: how green will the built environment be in 2015 to 2020?
Non-performing green companies will pay a penalty in that market!
![Page 33: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/33.jpg)
Take-Aways
Green building is important for controlling CO2 emissions
Many buildings are not performing as predicted or as needed
Without reporting performance, the entire exercise will be wasted
Energy use metrics are well known
![Page 34: Green Building Performance in Australia](https://reader038.vdocuments.us/reader038/viewer/2022110306/554e3b12b4c905f4478b4c90/html5/thumbnails/34.jpg)
If It Doesn’t Perform, It Can’t Be Green!
Jerry YudelsonYudelson Associates