gree electric appliances,inc.of zhuhai … and high energy f i c en yo tl r a comfortable living...

12
GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI Add:Jinji RD.Qianshan Zhuhai 519070,Guangdong,China Tel: (+86-756)8614883 Fax: (+86-756)8627140 Email: [email protected] http://www.gree.com.cn GREE , MAKING BETTER AIR CONDITIONERS Heat Pump Water Heater System Heat Pump Water Heater System

Upload: doannhan

Post on 23-May-2018

214 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI … and high energy f i c en yo tl r a comfortable living circumstance, but also save energy. Indoor temperature ... Water heating kW 2.0 2.0

GREE ELECTRIC APPLIANCES,INC.OF ZHUHAIAdd:Jinji RD.Qianshan Zhuhai 519070,Guangdong,ChinaTel: (+86-756)8614883 Fax: (+86-756)8627140Email: [email protected] http://www.gree.com.cn

GREE ,

MAKING BETTER AIR CONDITIONERS

Heat Pump Water Heater SystemHeat Pump Water Heater System

Page 2: GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI … and high energy f i c en yo tl r a comfortable living circumstance, but also save energy. Indoor temperature ... Water heating kW 2.0 2.0

Heat P

ump

Wate

r Heate

r Sys

tem

Page 3: GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI … and high energy f i c en yo tl r a comfortable living circumstance, but also save energy. Indoor temperature ... Water heating kW 2.0 2.0

01 02

2

Gree HOME-GMV unit perfectly unites DC variable frequency technology with heat

recovery technology and achieves joint operation of central air-conditioning system

and central water-heating system. It is declared by industrial authorities a

comprehensive air-conditioning and water-heating solution for modern homes.

□ Its unique five-mode operation (cooling, heating, water-heating, cooling + water-heating and heating + water

heating) is a breakthrough in traditional heat recovery technology where heating and water-heating cannot be

achieved at the same time.

□ By DC inverter technology, the compressor regulates output according to the workload for better energy

performance.

□ Thanks to heat recovery technology, free hot water is produced in cooling operation, achieving the highest

energy performance of 6.6, the best in the industry.

□ The multi-unit arrangement with one outdoor unit connected to several indoor units of various designs suits

perfectly your indoor decoration.

□ The combination of air-conditioner with water-heater saves precious floor space.

Extremely long connecting tubes adapt well to various apartment layouts.

□ The 10-16kW cooling output capacity is suitable for 80-200sqm apartments and multi-floor villas.

Unit Performances

4-side Ceiling Air Outlet Air Duct OutletWall-Type Unit Floor CeilingHOME-GMV

Outdoor U

nit

Hot Wind

Waste Heat Discharge

Cold Wind

Cooling Cooling

Traditional Air Conditioners

Large heat energy discharge into air during cooling. It wastes for nothing.

Home-GMV

Recycle waste heat to heat the cool water and get the free hot water.

Cold Wind

Outdoor U

nit

Waste

Heat R

eco

very

WaterTank

+ +

Grade A Energy Performance DCInverter Multi Air-Conditioner

GREE HOME-GMV

HOME-GMV

Cooling Heating Hot water

Three in one

G-4 Air-Source Heat Pump Water Heater

Page 4: GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI … and high energy f i c en yo tl r a comfortable living circumstance, but also save energy. Indoor temperature ... Water heating kW 2.0 2.0

03 04

2. Intelligent – Experience Carefree Living

Five-Mode Operation

□ Cooling:

□ Heating:

□ Water heating:

□ Cooling + Water heating:

□ Heating + Water heating:

Quick cooling in -5~48 degree Celsius outdoor temperature creates a cool and fresh world in the hot summer.

Strong heating in -15~24 degree Celsius outdoor temperature creates a warm world in the cold winter.

Comfortable, safe and healthy living water is provided.

Flexible energy saving process embodies to the best the heat recovery design.

Different from conventional air-conditioning water heating system, the heating and water heating functions here

can be put into use at the same time.

User-Friendly Control

□ Flexible and varied control system caters to different customers.

its previous running mode when it recovers from a power failure. The user,

however, may turn on/off this memory function.

Optional running mode memory enables the air-conditioner to restore to

system to run unattended in a variety of working

conditions, e.g., day or night, indoor or outdoor,

fine or cloudy, windy or raining, supplying hot

living water 24 hours a day without interruption.

Powerful automatic control enables the

wired controller remote controller centralized controller

store water in night use water in day

[ ][ ]Heat Recovery + DC Inverter = Higher Energy PerformanceHeat Recovery + DC Inverter = Higher Energy Performance

3.8kWQ2

2.8kWQ3

1. Double-Way Energy Saving

DC Inverter Technology

high system performance.

□ With stepless power regulation technology, the DC variable frequency

compressor achieves digital stepless output regulation between 20Hz-80Hz.

□ The features of 180 degree current output waveform, small startup current,

small torque pulse and free speed regulation between 900-6600rpm enable the

system to meet the temperature requirements of various circumstances, save

power consumption and ensure comfortable use.

World-brand dual-rotor DC inverter compressor ensures optimal output and

Heat Recovery Technology

□ The expertly designed refrigerating system heat recovery

technology and exhaust heat recovery technology have been

granted China invention and application patents.

□ During cooling operation, the condensing heat is recovered

and reused to heat living water. Therefore, free hot water is

produced when the refrigerating system is on.

□ The comprehensive energy performance of 6.6, the highest

in the industry.

Unit Advantages

New compressor structure.Increast the performanceof median frequency.

The new DC motor increasethe performance of low frequency

Traditional Compressor

Indoor temperature

Settingtemperature

Large fluctuate

Too cold

Time

On Off On Off On

Rated cooling capacity

Frequently turn on and turn off cause large temperature fluctuate.

Traditional DC Inverter compressor

Gree DC Invertercompressor

The cooling speed is slow and the tempera ture fluctuate is large.

The inverter technology with high-power and high energy efficiency not only create comfortable living circumstance, but also save energy.

Indoor temperature

Settingtemperature

Time

On Off Rated cooling capacity

Indoor temperature

Settingtemperature

Time

On

Rated cooling capacity

Heat recovery

Heating water

Heat energy

1kWQ1

Electric energy

Cooling capacity

Indoor cooling

Home-GMV

The comprehensive EER of Home-GMVreaches 6.6 which save more money.

Com

pres

sor

Inve

rter

com

pre

ssor

Dig

ital D

C in

verter

com

pre

ssor

Temperatureequation

Page 5: GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI … and high energy f i c en yo tl r a comfortable living circumstance, but also save energy. Indoor temperature ... Water heating kW 2.0 2.0

05 06

Indoor Unit

Indoor units of various designs are available to suit your indoor furnishings.Indoor units of various designs are available to suit your indoor furnishings.

Cassette Unit

□ Air supply in different directions with 30-75 degree sweep

for even temperature distribution .

□ Lasting filter cleaning and high-lift condensing pump.

Square panel in same size for easy installation.

Air Duct Unit

□ Flexible and easy to install in type-L, type-U and large

rooms.

□ Designed with fresh air baffle for fresh air introduction.

Wall-Type Unit

□ Streamlined design for spaces without ceiling.

□ Cold wind prevention design with multi-layer protection.

Floor Ceiling Unit

□ Floor ceiling type satisfies your more requirement for the

space.

3. Comfortable – Enjoy a Wonderful Life

Suitable Water Temperature

between 35-65 degrees Celsius meets the user needs for various purposes.

□ Quick water heating in large volume ensures hot water supply to different locations.

□ Electronic expansion valve guarantees precise automatic temperature regulation

and constant water temperature.

Hot water from central air-conditioning system with free temperature setting

4. Fashionable – Tells Your Class

Outdoor Unit

specific outdoor unit bay. This system not only saves space but also avoids the damage to the house facing integrity

due to the installation of many outdoor units.

Air-conditioner and water heater only need one outdoor unit, which is placed in the balcony, on the roof or in a

Hot water

Co

ol w

ate

r

Lavabo Bathtub Kitchen

(Multi type: one outdoor unit plus multi indoor unit) (Single type: one outdoor unit plus one indoor unit)

Page 6: GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI … and high energy f i c en yo tl r a comfortable living circumstance, but also save energy. Indoor temperature ... Water heating kW 2.0 2.0

07 08

GMV-Pds100W/Na-K GMV-Pds120W/Na-K GMV-Pds140W/Na-K GMV-Pds160W/Na-K

Capacity Cooling/Heating kW 10.0/11.0 12.0/13.2 14.0/15.4 16.0/17.6

W/W 6.6 6.6 6.6 6.6

kW 5.0 5.0 8.0 8.0

dB(A) 56 56 58 60

kg 5.0 5.0 7.0 7.0

V-Ph-Hz

Cooling/Heating kW 4.5/3.8 5.0/4.2 5.5/4.9 5.9/5.3

Water heating kW 2.0 2.0 3.0 3.0

mm

mm 1110×450×1370 1110×450×1370 1110×450×1370 1110×450×1370

Gas(AC) inch

Liquid(AC) inch

Gas(Water) inch

Liquid(Water) inch

kg 105/115 105/115 115/125 115/125N.W./G.W

Connecting pipes

3/4

3/8

5/8

1/2

Rate power input

Outline dimension (W×D×H) 950×340×1250

Package dimension (W×D×H)

50(Default), 35~65(Adjustable temperature range)

Noise

R410A charged volume

Power supply 220~240V,1Ph,50Hz

Model

COP(Heating)*

Rated water heating capacity

Water temperature

Outdoor Unit

RQD8GA-K RQD5GA-K

mm 650×300×250

mm 725×365×313

V-Ph-Hz 220~240V,1Ph,50Hz 220~240V,1Ph,50Hz

Liquid inch

Gas inch 5/8

Water inlet inch 3/4

Water outlet inch

meter 6

kg 25/28N.W./G.W

Connecting pipes

Refrigerant side

Water side

Water pump lift

Outline Dimension (W×D×H)

Package Dimension (W×D×H)

Power supply

650×300×250

725×365×313

3/4

Hydro-Box model

5/8

3/4

6

25/28

3/4

Hydro-Box

Parameters

Water Tank

SXD250LC-K SXD300LC-K SXD350LC-K SXD400LC-K

L 250 300 350 400

Outline (Diameter×Ht) mm 540×1945 620×1600 620×1895 620×2125

Package (W D H)× × mm 625× 1970630× 705×710×1645 705×710×1920 705×710×2150

Auxiliary electrical heater Rate power input kW 1.5 1.5 1.5 1.5

kg 68/77 71/81 79/90 86/98N.W./G.W

Water tank model

Tank volume

Dimension

Waterpipesdiameter

Cool water inlet

Hot water inlet

inch

inch

1/2

1/2

1/2 1/2 1/2

1/2 1/2 1/2

1/2 1/2

* This cop is tested under the mode of cooling+water heating.

80

130

80

130

80 160

GMV-Pds100W/Na-K

GMV-Pds120W/Na-K

GMV-Pds140W/Na-K

GMV-Pds160W/Na-K 80 160

RQD8GA-K SXD350LC-K or SXD400LC-K GMV-Pds160W/Na-K

GMV-Pds140W/Na-K

GMV-Pds120W/Na-K

GMV-Pds100W/Na-K RQD5GA-K SXD250LC-K SXD300LC-Kor

5. Safe – Cares Your Concerns

well as startup delay rule out any possibility of creepage, dry heating, ultra-high temperature, etc.

□ The fact that no fuel duct or tank is used removes the risk of fuel leakage, fire hazard or

explosion danger.

□ After long winter without using the unit, by turns on the draw off valve to drain the water to

avoids the frost crack of the sleeving inside the unit.

In-unit high and low voltage protection, compressor over current and over load protection as

6. Convenient – Facilitates Installation Work

□ Pressure water tank is adopted in the system and tap water pressure is exploited to drive hot water, saving such

parts as circulating water pump, flow switch and water level gauge.

Primary refrigerant system and simple piping and wiring ensure easy and low-cost installation.

☆ ☆ Total capacity of indoor units can be set to 50-120% of the outdoor unit capacity.Total capacity of indoor units can be set to 50-120% of the outdoor unit capacity.

☆ ☆ Outdoor unit, hydro-box and water tank matching:Outdoor unit, hydro-box and water tank matching:

Central Hot Water System

Central Air Conditioners System

Outdoor Unit

Water Tank

Hydro-box

Duct Type Indoor Unit

The sum of the min. capacity

of indoor units

The sum of the max. capacity

of indoor units

The model of hydro-box Recommend tank capacity (L)

Page 7: GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI … and high energy f i c en yo tl r a comfortable living circumstance, but also save energy. Indoor temperature ... Water heating kW 2.0 2.0

09 10

Cassette unit

GMVL-R71T/Na-K GMVL-R80T/Na-K GMVL-R90T/Na-K GMVL-R100T/Na-K GMVL-R112T/Na-K GMVL-R125T/Na-K

GMV-R71T/Na-K GMV-R80T/Na-K GMV-R90T/Na-K GMV-R100T/Na-K GMV-R112T/Na-K GMV-R125T/Na-K

Cooling kW 7.1 8.0 9.0 10.0 11.2 12.5

Heating kW 8.0 8.8 10.0 11.0 12.5 13.5

V-Ph-Hz

W 35 35 60 60 60 60

1180 1180 1860 1860 1860 1860

CFM 695 695 1095 1095 1095 1095

dB(A) 39 39 40 40 40 40

Outline WxDxH mm 840x840x240 840x840x240 840x840x320 840x840x320 840x840x320 840x840x320

Package WxDxH mm 960x960x310 960x960x310 960x960x394 960x960x394 960x960x394 960x960x394

Net weight kg 30 30 38 38 38 38

Gross weight kg 38 38 46 46 46 46

Outline WxDxH mm 950x950x60 950x950x60 950x950x60 950x950x60 950x950x60 950x950x60

Package WxDxH mm 1040x1025x115 1040x1025x115 1040x1025x115 1040x1025x115 1040x1025x115 1040x1025x115

Net weight kg 6.5 6.5 6.5 6.5 6.5 6.5

Gross weight kg 10 10 10 10 10 10

Gas inch

Liquid inch

Panel

Connecting pipediameter

Motor power input

Air flow volume

Sound pressure level

Main body

Cooling only

Heat pump

Capacity

Power supply

Model

3m /h

5/8

3/8

5/8 5/8

3/8 3/8

5/8 5/8 5/8

3/8 3/8 3/8

Floor Ceiling unit

GMVL-R28Zd/Na-K GMVL-R36Zd/Na-K GMVL-R50Zd/Na-K GMVL-R71Zd/Na-K GMVL-R90Zd/Na-K GMVL-R112Zd/Na-K GMVL-R125Zd/Na-K

GMV-R28Zd/Na-K GMV-R36Zd/Na-K GMV-R50Zd/Na-K GMV-R71Zd/Na-K GMV-R90Zd/Na-K GMV-R112Zd/Na-K GMV-R125Zd/Na-K

Cooling kW 2.8 3.6 5.0 7.1 9.0 11.2 12.5

Heating kW 3.2 4.0 5.8 8.0 10.0 12.5 13.5

V-Ph-Hz

W 10 10 40 100 150 180 180

550 600 700 1170 2100 2200 2300

CFM 324 353 412 689 1236 1294 1353

dB(A) 43 44 50 48 51 54 55

Outline dimension WxDxH mm 840×238×695 1300×188×600 1590×238×695

Package dimension WxDxH mm 1035×295×805 1514×248×724 1814×330×830

kg 28 28 28 34 44 44 44

kg 37 37 37 38 53 53 53

Gas inch

Liquid inch

Sound pressure level

Net Weight

Gross weight

Connecting pipediameter

Capacity

Power supply

Motor power input

Air flow volume

ModelCooling only

Heat pump

3/8

1/4 1/4 1/4

5/8

3/8

5/8 5/8

3/8 3/8

5/8

3/8

840×238×695

1035×295×805

840×238×695

1035×295×805

1590×238×695 1590×238×695

1814×330×830 1814×330×830

3m /h

GMVL-R28T/Na-K GMVL-R36T/Na-K GMVL-R45T/Na-K GMVL-R50T/Na-K GMVL-R56T/Na-K GMVL-R63T/Na-K

GMV-R28T/Na-K GMV-R36T/Na-K GMV-R45T/Na-K GMV-R50T/Na-K GMV-R56T/Na-K GMV-R63T/Na-K

Cooling kW 2.8 3.6 4.5 5.0 5.6 6.3

Heating kW 3.2 4.0 5.0 5.8 6.3 7.0

V-Ph-Hz

W 35 35 35 35 35 35

680 680 680 680 1180 1180

CFM 400 400 400 400 695 695

dB(A) 37 37 37 37 39 39

Outline WxDxH mm 840x840x190 840x840x190 840x840x190 840x840x190 840x840x240 840x840x240

Package WxDxH mm 960x960x257 960x960x257 960x960x257 960x960x257 960x960x310 960x960x310

Net weight kg 25 25 25 25 30 30

Gross weight kg 33 33 33 33 38 38

Outline WxDxH mm 950x950x60 950x950x60 950x950x60 950x950x60 950x950x60 950x950x60

Package WxDxH mm 1040x1025x115 1040x1025x115 1040x1025x115 1040x1025x115 1040x1025x115 1040x1025x115

Net weight kg 6.5 6.5 6.5 6.5 6.5 6.5

Gross weight kg 10 10 10 10 10 10

Gas inch 3/8 5/8 5/8

Liquid inch 1/4 1/4 1/4 1/4 3/8 3/8

Main body

Panel

Connecting pipediameter

Power supply

Motor power input

Air flow volume

Sound pressure level

ModelCooling only

Heat pump

Capacity

3m /h

220-240V,1Ph,50Hz

220-240V,1Ph,50Hz

GMVL-R140T/Na-K

GMV-R140T/Na-K

14.0

14.5

60

1860

1095

40

840x840x320

960x960x394

38

46

950x950x60

1040x1025x115

6.5

10

5/8

3/8

220-240V,1Ph,50Hz

GMV-R22T/NaA-K GMV-R28T/NaA-K GMV-R36T/NaA-K GMV-R45T/NaA-K

2.2 2.8 3.6 4.5

2.5 3.2 4.0 5.0

12 12 12 12

600 600 600 600

353 353 353 353

47 47 47 47

570×570×230

848×728×310

20 20 20 20

27 27 27 27

650×650×50 650×650×50 650×650×50 650×650×50

5 5 5 5

10 10 10 10

3/8 3/8

1/4 1/4 1/4 1/4

GMVL-R22P/NaB-K GMVL-R25P/NaB-K GMVL-R28P/NaB-K GMVL-R36P/NaB-K GMVL-R45P/NaB-K

GMV-R22P/NaB-K GMV-R25P/NaB-K GMV-R28P/NaB-K GMV-R36P/NaB-K GMV-R45P/NaB-K

Cooling kW 2.2 2.5 2.8 3.6 4.5

Heating kW 2.5 2.8 3.2 4.0 5.0

V-Ph-Hz 220-240V,1Ph,50Hz

W 75 75 80 80 100

3m /h 450 450 570 570 840

CFM 265 265 335 335 494

Pa 20/0 20/0 20/0 20/0 50/20

dB(A) 37 37 39 39 40

Outline dimension W×D H× mm 870×680 260× 980 736 266× ×

Package dimension W D H× × mm 1012 780 315× × 1068 766 320× ×

kg 27 27 27 27 34

kg 31 31 31 31 37

Gas inch 3/8

Liquid inch

Sound pressure level

Net Weight

Gross weight

Connecting pipediameter

Power supply

Motor power input

Air flow volume

Standard Esp

ModelCooling only

Heat pump

Capacity

3/8 3/8

1/4 1/4 1/4 1/4 1/4

GMVL-R56P/NaB-K GMVL-R71P/NaB-K GMVL-R90P/NaB-K GMVL-R112P/NaB-K GMVL-R140P/NaB-K

GMV-R56P/NaB-K GMV-R71P/NaB-K GMV-R90P/NaB-K GMV-R112P/NaB-K GMV-R140P/NaB-K

Cooling kW 5.6 7.1 9.0 11.2 14.0

Heating kW 6.3 8.0 10.0 12.5 15.0

V-Ph-Hz

W 240 360 500

3m /h 1400 2000 2500

CFM 824 1177 1471

Pa 60/30 80/40 100/50

dB(A) 44 48 50

Outline dimension W×D H× mm 1112×756 300× 1425 756 300× × 1463 756 300× ×

Package dimension W D H× × mm 1245 785 360× × 1514 785 360× × 1555 810 345× ×

kg 49 62 64

kg 56 71 73

Gas inch 5/8

Liquid inch

Sound pressure level

Net Weight

Gross weight

Connecting pipediameter

Power supply

Motor power input

Air flow volume

Standard Esp

ModelCooling only

Heat pump

Capacity

5/8

3/8

240

1400

824

60/30

44

1112 756 300× ×

1245 785 360× ×

49

56

5/8

3/8 3/8

360

2000

1177

80/40

48

1425 756 300× ×

1514 785 360× ×

62

71

5/8

3/8

5/8

3/8

Model

Cooling kW

Heating kW

V-Ph-Hz

W

CFM

dB(A)

Outline WxDxH mm

Package WxDxH mm

Net weight kg

Gross weight kg

Outline WxDxH mm

Package WxDxH mm

Net weight kg

Gross weight kg

Gas inch

Liquid inch

Main body

Panel

Connecting pipe

diameter

Power supply

Motor power input

Air flow volume

Sound pressure level

Heat pump

Capacity

3m /h

Duct unit

220-240V,1Ph,50Hz

Cassette unit

220-240V,1Ph,50Hz

730×670×102 730×670×102 730×670×102 730×670×102

870×680 260×

1012 780 315× ×

870×680 260× 870×680 260×

1012 780 315× × 1012 780 315× ×

570×570×230

848×728×310

570×570×230 570×570×230

848×728×310 848×728×310

Page 8: GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI … and high energy f i c en yo tl r a comfortable living circumstance, but also save energy. Indoor temperature ... Water heating kW 2.0 2.0

11 12

Nominal Volume (L) Model Name Appearance

150

200

250

SX150LC/B1-K

SX200LC/B1-K

SX250LC/B1-K

Nominal Capacity (kW)

Model

Refrigerant Model Name

Power Supply(V, Ph, Hz)

Appearance

18 R22 GRS-Cm18/A-M 380,3,50

36 R22

65 R22

GRS-Cm36/A-M 380,3,50

GRS-Cm65/A-M 380,3,50

3.5 R22 GRS-C3.5/A1-K 220-240,1,50

5.0 R22 GRS-C5.0/A1-K 220-240,1,50

7.2 R22 GRS-C7.2/A1-K 220-240,1,50

Refrigerant

Nominal Capacity (kW)

Model

Model Name

Power Supply (V, Ph, Hz) Appearance

AIR SOURCE WATER HEATERAIR SOURCE WATER HEATER

AIR SOURCE WATER HEATERAIR SOURCE WATER HEATER

Controller

Controller

AIR SOURCE WATER HEATER

Models

Modular Circulating Water Heater

Single Circulating Water Heater

3.8

5.0

9.0

16.0

R134a

R134a

R410A

R410A

GRS-C3.8/NbA-K

GRS-C5.0/NbA-K

GRS-C9/Na-M

GRS-C16/Na-M

220-240,1,50

220-240,1,50

380-415,3,50

380-415,3,50

300 SX300LC/B1-K

350 SX350LC/B1-K

Non ElectricHeater

With ElectricHeater

400 SX400LC/B1-K

150 SXD150LC-K

200

250

300

SXD200LC-K

SXD250LC-K

SXD300LC-K

Outdoor Unit And Water Tank Matching

Outdoor Unit

GRS-C3.5/A1-K

GRS-C5.0/A1-K

GRS-C7.2/A1-K

GRS-C3.8/NbA-K

GRS-C5.0/NbA-K

Mounted unit

GMVL-R22G/NaB-K GMVL-R28G/NaB-K GMVL-R36G/NaB-K GMVL-R45G/NaB-K

GMV-R22G/NaB-K GMV-R28G/NaB-K GMV-R36G/NaB-K GMV-R45G/NaB-K

Cooling kW 2.2 2.8 3.6 4.5

Heating kW 2.5 3.2 4 5

V-Ph-Hz

W 14 14 22 22

m3/h 360 360 500 500

CFM 212 212 294 294

dB(A) 37/28 37/28 43/28 43/28

Outline dimension WxDxH mm 770×190×250 830×189×285

Package dimension WxDxH mm 955×330×272 1006×385×265

kg 8 8 11 11

kg 14.3 14.3 15.8 15.8

Gas inch

Liquid inch

Gross weight

Connecting pipe

diameter

Motor power input

Air flow volume

Sound pressure level (H/L)

Net Weight

Cooling only

Heat pump

Capacity

Power supply

Model

3/8

1/4

3/8

1/4 1/4 1/4

770×190×250

955×330×272

830×189×285

1006×385×265

GMVL-R50G/NaB-K GMVL-R56G/NaB-K GMVL-R71G/NaB-K GMVL-R80G/NaB-K

GMV-R50G/NaB-K GMV-R56G/NaB-K GMV-R71G/NaB-K GMV-R80G/NaB-K

Cooling kW 5.0 5.6 7.1 8.0

Heating kW 5.8 6.3 8 9

V-Ph-Hz 220-240V,1Ph, 50Hz

W 20 20 26 26

m3/h 700 750 1200 1200

CFM 412 441.5 706 706

dB(A) 45/40 45/40 49/42 49/42

Outline dimension WxDxH mm 1020×228×310 1178×227×326

Package dimension WxDxH mm 1178×325×390 1365×417×333

kg 15.5 15.5 17.5 17.5

kg 20.5 20.5 23 23

Gas inch

Liquid inch

Gross weight

Connecting pipe

diameter

Motor power input

Air flow volume

Sound pressure level (H/L)

Net Weight

Cooling only

Heat pump

Capacity

Power supply

Model

1/4

5/8

3/8

1020×228×310

1178×325×390

1178×227×326

1365×417×333

220-240V,1Ph,50Hz

5/8

3/8

5/8

3/8

Page 9: GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI … and high energy f i c en yo tl r a comfortable living circumstance, but also save energy. Indoor temperature ... Water heating kW 2.0 2.0

13 14

water.The energy consumption is one fourth of electric water heater and one third of gas water

heater with the same capacity.

It consumes electric energy which will generate about 4.6 times heating energy to heat

conversing device. For example, electric water

heater only transfers electric energy to hot water

and gas water heater transfers heat energy by

burning natural gas to hot water. Gree air source

water heater not only transfers electric energy to

hot water but also absorbs heat energy in air,

which will be transferred to hot water. So efficiency of it can reach up to 460%, i.e. 1kW electric

energy can generate 4.6kW heat energy.

Conventional water heater is just an energy-

machine room needed buy any place where without direct sunlight . Intelligent self-diagnose

system is provided for easy maintenance.

The unit can be installed on balcony, rooftop, yard, and basement and so on, no special

are more compact.

Compared with the similar type of products, 36kW and 65kW units with upper side air supply

Standard Features

High efficiency and energy saving

Easy Installation and Maintenance

1kWQ1

Electric energy

4.6kW 3.6kWQ3 Q2

Hot water Heat absorbing

Air absorbs heat

AIR SOURCE WATER HEATERAIR SOURCE WATER HEATER

Comfortable and reliable

water heater to ensure auto adjustment of throttling degree according to change of ambient

and water temperature. Water temperature within 35~60℃ can be adjusted casually(default

50℃). Water temperature deviation ≤1℃, so it is comfortable and accurate.

Electronic expansion valve, applying for patent by Gree exclusively, is used in air source

Accurate water temperature

Air source is a kind of low-grade energy which exists

widely and can be equally supplied and freely applied.

Upgraded by use of heat pump circulation, it can

potentially developed to a new kind of energy saving and

environment friendly technology with practical value.

Air source heat pump water heater by use of heat pump

principle will consume a part of electric energy for

compensation and obtain heat from low-grade energy

(low-temperature air source) around. The heat will be

sent to condenser and released to high-temperature

heat source to generate hot water. With the same

working principle as heat pump water heater, heat pump

air conditioner obtains heat from natural environment

which will be supplied to indoor air, but heat pump water

heater heats domestic water by this part of heat, so it's EER is at least 2 times higher than

conventional electric water heater. Heat pump water heater is kind of high efficiency, energy

saving and environment friendly product.

Heat pump unit usually consists of compressor, water side heat exchanger, air side heat

exchanger, throttling device, high/low pressure accumulator and so on. And air source heat

pump water heater consists of heat pump unit, insulated water tank, water pump, other relative

pipeline valves, etc.

Cold air Heat

exchanger

Compressor

Hot air

Expansion valve Low temp

Water side heat exchanger

High temperature High-temperature hot water

Heat-retaining water tank

Cold water

Hot water user

High-temperature hot water

Description

Page 10: GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI … and high energy f i c en yo tl r a comfortable living circumstance, but also save energy. Indoor temperature ... Water heating kW 2.0 2.0

15 16

hidden heat in the air as low-temperature heat source, so it

can continuously supply hot water all day no matter what

season or what weather like. It is designed to work at wide

ambient temperature range from -15 to 43℃.

Heat pump water heater makes use of sensible heat and

All-day Operation and Wide Application

enhances heat exchanging performance but also ensures

isolation between hot water and refrigerant. Cleaner water

makes your life healthier.

Special thickened inside-thread copper pipe not only

Safe and Reliable

world-famous parts and components ensure safe and

reliable operation of unit.

Special high-temperature condition compressor and

absorbs heat energy in air to heat water, so the water-electricity isolation is completely

realized. Potential fault like electric leakage of using electric water heater, gas poisoning,

explosion and dry combustion caused by using gas water heater will never happen on air

source heat pump water heater, so it is more safe and reliable than the conventional

water heater.

Electric energy drives refrigerant in air source heat pump water heater and refrigerant

unreliable water temperature.

Water temperature of water tank keeps even and constant .There is not any trouble of

according to your habit, giving you more comfortable

arrangement.

The unit can be started up for water heating in advance

Constant water temperature

which protects inner container for a long period of time

ensures clarity of water.

Water tank attached with super long magnesium stick

□ The unit with cleaning function can automatically clean

itself.

Auto cleaning , healthy on every day

□ Gree air source central water heater can be selected from various models and specifications

of main units. Enough water supply capacity and reasonable water system design of central hot

water system make water used by a lot of people simultaneously realized.

Multipoint water supply and simultaneous water using

Intelligent water supply and energy saving

Timer On , bathing at any time

be tracked.

□ Multi-modular network can control up to 16 host units; parameters of each unit can be

freely set. (This is applicable for GRS-Cm18/A-M)

□ Daily timer on/off function; complete safeties to ensure reliable operation.

Microchip control, easy operation interface, and various kind of history operation data can

Intelligent Control

Page 11: GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI … and high energy f i c en yo tl r a comfortable living circumstance, but also save energy. Indoor temperature ... Water heating kW 2.0 2.0

Water Tank

SXD150LC-K SXD200LC-K SXD250LC-K SXD300LC-K

L 150 200 250 300

kW 1.5 1.5 1.5 1.5

Outline (Diameter×Ht) mm 520×1350 540×1595 540×1945 620×1620

Package (W D H)× × mm 605 610 1375× × 625 630 1620× × 625 630 1970× × 675 680 1720× ×

Cool water inlet inch 1/2 1/2 1/2 1/2

Hot water outlet inch 1/2 1/2 1/2 1/2

kg 45/52 57/66 68/77 71/81

Tank volume

Dimension

N.W./G.W

Auxiliary electrical heater power input

water pipes

diameter

Water tank model

With Electric Heater

Non Electric Heater

L

Outline (Diameter×Ht) mm

Package (W D H)× × mm

Cool water inlet inch

Hot water outlet inch

kg

Tank volume

Dimension

N.W./G.W

water pipes

diameter

Water tank model SX150LC/B1-K

150

520x1350

605x610x1375

1/2

1/2

42/50

SX200LC/B1-K

200

540x1595

625x630x1620

1/2

1/2

55/63

SX250LC/B1-K

250

540x1945

625x630x1970

1/2

1/2

66/75

SX300LC/B1-K

300

620x1620

675x680x1720

1/2

1/2

69/79

SX350LC/B1-K

350

620x1895

705x710x1920

1/2

1/2

77/88

SX400LC/B1-K

400

620x2125

705x710x2150

1/2

1/2

84/96

AIR SOURCE WATER HEATERAIR SOURCE WATER HEATER

17

kW

L/h

dB(A)

kg

V-Ph-Hz

Rate power input Water heating kW

W/W

mm

mm

inch

Model

Rated water heating capacity

Rated water supply

Water temperature

Noise

R22 charged volume

Power supply

N.W./G.W.

Outline dimension (W×D×H)

Package dimension (W×D×H)

Connecting pipes

COP(Heating)*

GRS-C9/Na-M

9

193

45

60

3.2

380~415V,3Ph,50Hz

2.5

3.6

1018×840×412

1110×880×450

3/4

1/2

90/100

Gas(AirCon)

Liquid(AirCon)

kg

inch

R410a, 50Hz

GRS-C16/Na-M

16

343

45

62

4.5

380~415V,3Ph,50Hz

4.5

3.6

950×1250×340

1110×1280×450

3/4

1/2

132/145

NOTE:The inner coils water tank must be matched by user.

kW

L/h

dB(A)

kg

V-Ph-Hz

Water heating kW

W/W

mm

mm

inch

kg

Model

Rated water heating capacity

Rated water supply

Water temperature

Noise

R22 charged volume

Power supply

N.W./G.W.

Outline dimension (W×D×H)

Package dimension (W×D×H)

Connecting pipes to water tank

COP(Heating)*

GRS-C3.8/NbA-K

3.8

82

70

50

0.7

220~240V,1Hp,50Hz

1.02

3.73

762×256×750

878×360×800

3/4

50/61

Parameters

Outdoor Unit

GRS-C3.5/A1-K GRS-C5.0/A1-K GRS-C7.2/A1-K

kW 3.5 5 7.2

L/h 75 108 155

℃ 58 58 58

dB(A) 50 52 53

kg 0.65 1 1

V-Ph-Hz 220~240V,1Ph 50Hz, 220~240V,1Ph 50Hz, 220~240V,1Ph 50Hz,

Power input Water heating kW 0.9 1.15 1.75

W/W 3.89 4.35 4.11

mm 762×256×750 762×256×750 870×378×882

mm 878× ×360 800 878× ×360 800 930× ×428 994

inch 3/4 3/4 3/4

kg 50/55 55/61 68/79

Model

Rated water heating capacity

Rated water supply

Water temperature

Noise

R22 charged volume

Power supply

N.W./G.W.

Outline dimension (W×D×H)

Package dimension (W×D×H)

Connecting pipes to water tank

COP(Heating)*

R22, 50Hz

AIR SOURCE WATER HEATERAIR SOURCE WATER HEATER

kW

L/h

dB(A)

kg

V-Ph-Hz

Water heating kW

W/W

mm

mm

inch

kg

Model

Rated water heating capacity

Rated water supply

Water temperature

Noise

R22 charged volume

Power supply

N.W./G.W.

Outline dimension (W×D×H)

Package dimension (W×D×H)

Connecting pipes to water tank

COP(Heating)*

GRS-Cm18/A-M

18

392

55

≤60

4

380V,3Ph,50Hz

4.5

4

1100×410×1250

1250×450×1270

1

150/165

GRS-Cm36/A-M

36

780

55

 ≤65

8.4

380V,3Ph,50Hz

8.7

4.14

1460×530×1850

1560×710×1960

1

380/400

GRS-Cm65/A-M

65

1400

55

≤68

17

380V,3Ph,50Hz

14.5

4.48

1750×800×1760

1860×900×1870

1-1/2

450/470

AIR SOURCE WATER HEATERAIR SOURCE WATER HEATER

R134a, 50Hz

Power input

Power input

GRS-C5.0/NbA-K

5.0

108

70

52

0.95

220~240V,1Hp,50Hz

1.35

3.70

762×256×750

878×360×800

3/4

50/61

18

Page 12: GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI … and high energy f i c en yo tl r a comfortable living circumstance, but also save energy. Indoor temperature ... Water heating kW 2.0 2.0

NOTE