Page 1: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

2

GraphiteVPX/GbE 20-Port Managed Carrier Ethernet Switch

Connect Tech Inc. Tel: 519-836-1291

42 Arrow Road Toll: 800-426-8979 (North America only) Guelph, Ontario Fax: 519-836-4878 N1K 1S6 Email: [email protected] www.connecttech.com [email protected] CTIM-00461 Revision 0.02 2016/10/27

Page 2: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 2 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Table of Contents

Table of Contents ................................................................................................................................... 2

Preface ................................................................................................................................................... 3

Disclaimer ....................................................................................................................................................... 3 Customer Support Overview ........................................................................................................................... 3 Contact Information ........................................................................................................................................ 3 Limited Product Warranty ............................................................................................................................... 4 Copyright Notice ............................................................................................................................................. 4 Trademark Acknowledgment .......................................................................................................................... 4 ESD Warning .................................................................................................................................................. 5

Revision History .................................................................................................................................... 5

Introduction........................................................................................................................................... 6

Product Overview .................................................................................................................................. 8

Block Diagram ................................................................................................................................................ 8 Ordering Part Numbers ................................................................................................................................... 9 Connector Locations (VPG201) .................................................................................................................... 10 Connector Summary ...................................................................................................................................... 11

VPG20x - Detailed Feature Pinouts ...................................................................................................... 12

CLI Management Interface .................................................................................................................. 13

CLI Access via the RS232 Serial Port ........................................................................................................... 13 CLI Basics ..................................................................................................................................................... 14 Complete CLI and Protocol Configuration Reference Guide ........................................................................ 14

Web Management Interface ................................................................................................................. 15

Accessing the Web Management Interface ................................................................................................... 15 Web Management Interface Overview .......................................................................................................... 16 Complete Web Protocol Configuration Reference Guide ............................................................................. 16

Port LED Details ................................................................................................................................. 17

System Management Interface ............................................................................................................. 18

Addressing the I2C Slave Interface (I2C Mux) ............................................................................................. 18 Writing to the I2C Slave Interface................................................................................................................. 19 Reading from the I2C devices ....................................................................................................................... 19

Thermal Details ................................................................................................................................... 20

Thermal Parameters ....................................................................................................................................... 20

Mechanical Details ............................................................................................................................... 21

3D STEP Models ........................................................................................................................................... 21 VPG202 Top Side View ................................................................................................................................ 22 VPG202 – Bottom Side View ....................................................................................................................... 23

RTM Details ........................................................................................................................................ 24

RTG002 – Pinout Information ...................................................................................................................... 25 RTG002 – Top Side View ............................................................................................................................. 26 RTG002 – Bottom Side View ....................................................................................................................... 26

Page 3: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 3 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Preface

Disclaimer The information contained within this user’s guide, including but not limited to any product specification, is

subject to change without notice.

Connect Tech assumes no liability for any damages incurred directly or indirectly from any technical or

typographical errors or omissions contained herein or for discrepancies between the product and the user’s

guide.

Customer Support Overview If you experience difficulties after reading the manual and/or using the product, contact the Connect Tech

reseller from which you purchased the product. In most cases the reseller can help you with product installation

and difficulties.

In the event that the reseller is unable to resolve your problem, our highly qualified support staff can assist you.

Our support section is available 24 hours a day, 7 days a week on our website at:

www.connecttech.com/sub/support/support.asp. See the contact information section below for more

information on how to contact us directly. Our technical support is always free.

Contact Information

Mail/Courier Connect Tech Inc.

Technical Support

42 Arrow Road

Guelph, Ontario

Canada N1K 1S6

Email/Internet

[email protected]

[email protected]

www.connecttech.com

Note:

Please go to the Download Zone or the Knowledge Database in the Support Center on the Connect Tech

website for product manuals, installation guides, device driver software and technical tips.

Submit your technical support questions to our customer support engineers via the Support Center on the

Connect Tech website.

Telephone/Facsimile

Technical Support representatives are ready to answer your call Monday through Friday, from 8:30 a.m. to

5:00 p.m. Eastern Standard Time. Our numbers for calls are: Toll Free: 800-426-8979 (North America only)

Telephone: 519-836-1291 (Live assistance available 8:30 a.m. to 5:00 p.m. EST, Monday to Friday)

Facsimile: 519-836-4878 (on-line 24 hours)

Page 4: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 4 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Limited Product Warranty

Connect Tech Inc. provides a 2 year Warranty for the GraphiteVPX/GbE 20-Port - Managed Carrier Ethernet

Switch. Should this product, in Connect Tech Inc.'s opinion, fail to be in good working order during the

warranty period, Connect Tech Inc. will, at its option, repair or replace this product at no charge, provided that

the product has not been subjected to abuse, misuse, accident, disaster or non-Connect Tech Inc. authorized

modification or repair.

You may obtain warranty service by delivering this product to an authorized Connect Tech Inc. business

partner or to Connect Tech Inc. along with proof of purchase. Product returned to Connect Tech Inc. must be

pre-authorized by Connect Tech Inc. with an RMA (Return Material Authorization) number marked on the

outside of the package and sent prepaid, insured and packaged for safe shipment. Connect Tech Inc. will

return this product by prepaid ground shipment service.

The Connect Tech Inc. Limited Warranty is only valid over the serviceable life of the product. This is defined

as the period during which all components are available. Should the product prove to be irreparable, Connect

Tech Inc. reserves the right to substitute an equivalent product if available or to retract the Warranty if no

replacement is available.

The above warranty is the only warranty authorized by Connect Tech Inc. Under no circumstances will

Connect Tech Inc. be liable in any way for any damages, including any lost profits, lost savings or other

incidental or consequential damages arising out of the use of, or inability to use, such product.

Copyright Notice

The information contained in this document is subject to change without notice. Connect Tech Inc. shall not

be liable for errors contained herein or for incidental consequential damages in connection with the furnishing,

performance, or use of this material. This document contains proprietary information that is protected by

copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to

another language without the prior written consent of Connect Tech, Inc.

Copyright 2015 by Connect Tech, Inc.

Trademark Acknowledgment

Connect Tech, Inc. acknowledges all trademarks, registered trademarks and/or copyrights referred to in this

document as the property of their respective owners. Not listing all possible trademarks or copyright

acknowledgments does not constitute a lack of acknowledgment to the rightful owners of the trademarks and

copyrights mentioned in this document.

Page 5: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 5 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

ESD Warning

Electronic components and circuits are sensitive to

ElectroStatic Discharge (ESD). When handling any circuit

board assemblies including Connect Tech COM Express

carrier assemblies, it is recommended that ESD safety

precautions be observed. ESD safe best practices include,

but are not limited to:

Leaving circuit boards in their antistatic packaging

until they are ready to be installed.

Using a grounded wrist strap when handling circuit

boards, at a minimum you should touch a grounded

metal object to dissipate any static charge that may be

present on you.

Only handling circuit boards in ESD safe areas, which

may include ESD floor and table mats, wrist strap

stations and ESD safe lab coats.

Avoiding handling circuit boards in carpeted areas.

Try to handle the board by the edges, avoiding contact

with components.

Revision History Revision Date Changes

0.00 27/04/2016 Initial Release

0.01 18/06/2016 Added I2C sensor info, updated pictures.

0.02 27/10/2016 Removed pinout details, updated title page

Page 6: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 6 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Introduction

Connect Tech’s GraphiteVPX/GbE Managed Ethernet Switch provides Carrier Grade Ethernet switching

capabilities in a small 3U embedded form factor. Excellent for demanding applications with rugged

environments and extreme temperatures.

The GraphiteVPX/GbE Managed Ethernet Switch is also a highly reliable way to communicate with

10/100/1000 Base-T devices in an embedded system. Powered by the latest generation Carrier Ethernet Switch

engine, the Vitesse 7429 features an embedded MIPS 32-bit CPU, 1Gb external memory and DMA-based

frame extraction and insertion support timing over packet, Ethernet OAM, and performance monitoring.

Feature

Description

Ethernet Switch Engine

Vitesse VSC7429 Carrier Grade Ethernet Switch Chipset

A powerful embedded 416 MHz RISC 32-bit CPU with DDR2

external memory and DMA-based frame extraction and insertion supports

timing over packet, Ethernet OAM, and performance monitoring.

Ethernet PHYs

8 x Cu PHY Ports from Vitesse VSC7429 Switch Engine 12 x Cu PHY Ports from Vitesse VSC8512 External PHY

Memories

1Gb DDR2 SDRAM (125MB)

128Mb Serial NOR Flash (16MB)

Ports

20 x Gigabit Ethernet (10/100/1000 Mbps )

Magnetics

On-board Gigabit Magnetics for all 20 Ports (No external Magnetics required)

Designed for Long-haul Gigabit Ethernet (10/100/1000 Mbps) applications

I/O Connectors

Standard VPX Backplane connectors

4x RJ45 front panel connectors

RJ11 connector for RS232 CLI access

Layer 2 Switching

802.1Q VLAN switch with 8K MACs and 4K VLANs

Push/pop up to two VLAN tags

IPv4/IPv6 multicast

Policing with storm control and MC/BC protection

RSTP and MSTP support

Hardware and software-based learning

Link aggregation (IEEE 802.3ad)

Independent and shared VLAN learning (IVL, SVL)

Jumbo frame support

Management Access

Web Interface

CLI via RS-232

Software API SMNP

Page 7: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 7 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Indicator LEDs

2 LEDs per port indicating connection speed Power Good LED

Fail Status LED

Thermal Trip LED

Standalone Operation

Switch is used as a standalone unit

Input Voltage

5V (VS3) and 3.3V_AUX

Power Consumption

Idle: 1.8A, 9W Typical: 2A, 10W Max: 3A, 15W (with +5V input)

Dimensions

Standard 1” Pitch VPX

Weight

VPG201 = 380g

VPG202 = 390g

Operating Temp

-40°C to +85°C (chipset rated to +125°C TJmax)

Warranty and Support

Two Year Warranty and Free Technical Support

Page 8: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 8 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Product Overview The

Block Diagram

Page 9: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 9 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Ordering Part Numbers

Part Number Photo Description

VPG201

Air Cooled 20 port GbE Switch, 16 backplane

channels, 4 RJ45 channels on the front panel

VPG202

Conduction Cooled 16 port GbE Switch, 16

backplane channels

RTG002

3U extended RTM, with 16 RJ45 channels

Page 10: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 10 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Connector Locations (VPG201)

Note the VPG202 has P3 and P4 removed.

Page 11: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 11 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Connector Summary

Designator Connector Description

P0 VPX P0 Standard VPX connector, has all POWER, CTRL

signals

P1 VPX P1 Is fully populated with 8 GbE BaseT channels

P2 VPX P2 Is fully populated with 8 GbE BaseT channels

P3 RJ11 RJ11 for serial communications with the Ethernet

switch, VPG201 only

P4 RJ45 4x RJ45 connectors for additional access

J1 2x5 Jumper Block N/A

Page 12: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 12 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

VPG20x - Detailed Feature Pinouts

Full pinout details are available only under an NDA (Non-Disclosure Agreement). Please contact sales at Connect

Tech Inc. for further information.

1-800-426-8979

[email protected]

http://www.connecttech.com

Page 13: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 13 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

CLI Management Interface

CLI Access via the RS232 Serial Port To use the CLI management on the VPG you must connect to the RS-232 external management serial port (P3)

or through the backplane serial port connection. Only TX, RX and GND connections are needed for operation.

You then must open the serial port in a terminal program such as: RealTerm, Putty, HyperTerminal, minicom,

etc. The COM port must be set up to run with a baud rate of 115200, 8 data bits, 1 stop bit and no parity.

Note: the VPG external serial port is compatible with RS-232 Input/Output Levels (NOT TTL or CMOS).

RS-232 Serial Parameter Value

Baud Rate 115200 bps

Data Bits 8

Parity None

Stop Bit 1

Output Voltage Swing ±4.2 V

Input Voltage Range ±15 V

Input Threshold Low 0.8 V

Input Threshold High 2.4 V

Page 14: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 14 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

CLI Basics

Once opening the COM port attached to the management port, after boot up your terminal output should look

like the output below. The default login is admin and password is blank(“”). So after typing admin hit

<ENTER> then hit <ENTER> again to login and “?” will display a list of the available commands.

Below is a list of common quick CLI commands. For a complete CLI reference please see the documents

described below.

Common Task CLI Command Syntax

Help menu – from any level, add a ‘?’ to the

end of a command for a list of options at that

level.

show ? OR show ip int ?

What are the IP addresses used by my

switch?

show ip int br

What ports are linked and at what speed? show int * status

What software version is on my switch? show ver

How do I save my configuration? copy running-config startup-config

How do I setup my IP address for vlan1? conf t

int vlan 1

ip add xxx.xxx.xxx.xxx 255.255.255.0

end

Complete CLI and Protocol Configuration Reference Guide

The complete CLI and Protocol Configuration reference guide from Microsemi for the VSC7429 device can be

downloaded here.

The following documents:

- AN1104-Software_Configuration_Guide_ICLI

- AN1115Layer2ProtocolConfigurationGuide

Will have the below mentioned copyright notice.

Copyright 2002-2015 Microsemi Corporation. All Rights Reserved. Unpublished rights reserved under the

copyright laws of the United States of America, other countries and international treaties. Microsemi retains

all ownership, copyright, trade secret and proprietary rights in the documentation.

Page 15: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 15 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Web Management Interface The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor

the device from any web enabled device. Below describes how to access this management interface as well as

provides on overview on the web GUI itself.

Accessing the Web Management Interface

There are two ways to access the web interface for first time use.

Method #1 - Using the default shipping IP

This method DOES NOT require having access to the CLI interface. By default the GraphiteVPX/GbE will

have an IP address of 192.168.42.1, if you would like to connect to this address follow the steps below:

o Directly connect any port of GraphiteVPX/GbE to your host PC using a standard Cat5e ethernet

cable

o Setup your host PC’s IP address to be on the same subnet as GraphiteVPX/GbE (192.168.42.X)

o Open a web browser and go to the 192.168.42.1 address.

o Now you should see the login screen and from here you can setup the GraphiteVPX/GbE to an IP

address on your network.

Method #2 – Changing the GraphiteVPX/GbE IP to one on your network via the CLI

This method requires having access to the CLI interface through means of the external management serial port

or the PCIe/104 bus

o Login to the CLI interface

o Type in the following commands

o configure terminal

o interface vlan 1

o ip address xxx.xxx.xxx.xxx 255.255.255.0

o end

o Now connect GraphiteVPX/GbE to any place on your network.

o Once the system is up simply go to your specified address of xxx.xxx.xxx.xxx in a web browser of

your choice and you will see the login screen for the web interface

Login Screen of Web Management Interface

To login into the web management interface, the default login is admin and the password is blank.

(See below)

Page 16: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 16 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Web Management Interface Overview

Complete Web Protocol Configuration Reference Guide

As mentioned in the CLI section, the complete Protocol Configuration reference guide from Microsemi for the

VSC7429 device can be downloaded here. It will have CLI and Web configuration methods listed.

The following document:

- AN1115Layer2ProtocolConfigurationGuide

Will have the below mentioned copyright notice.

Copyright 2002-2015 Microsemi Corporation. All Rights Reserved. Unpublished rights reserved under the

copyright laws of the United States of America, other countries and international treaties. Microsemi retains

all ownership, copyright, trade secret and proprietary rights in the documentation.

Page 17: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 17 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Port LED Details The VPG uses a serialized LED stream to output the LED status for each port. This serial signal is intended to

be run through shift registers as shown below to de-serialize the stream. To accommodate the 16 ports

(VPG202 – Backplane only) requires the use of four 8-bit shift registers (or eqivilant) setup in the

configuration shown below.

An example circuit is shown below, or an example schematic can be downloaded here.

Page 18: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 18 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

System Management Interface

The GraphiteVPX/GbE supports a slave I2C slave interface on the SM0 (SCL) and SM1 (SDA) signals

connected to the VPX backplane. The I2C address of this interface is determined by the Geographic Address

lines GA0#, GA1#, and GA2#. This interface operates at 100 KHz.

There are 10K OHM pull-ups to the +3.3V_AUX supply on the I2C slave interface on SM0 and SM1.

The I2C interface contains an I2C mux device (PCA9544) to allow the user access 5 temperature sensors that

monitor board edges and internal temperatures of the Ethernet Switch and Ethernet PHY.

Addressing the I2C Slave Interface (I2C Mux)

As stated above, the I2C slave interface uses GA0#, GA1#, and GA2# to determine its final I2C address. See

more details below. Refer to your backplane GA (Geographical Address) lines for the complete configuration

address.

The I2C address will be as such:

Bit7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0

1 1 1 0 GA2# GA1# GA0# R/W

Page 19: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 19 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Writing to the I2C Slave Interface

Refer to the NXP PCA9544 datasheet for access details.

The I2C multiplexor is like a ‘gate’ to open an on board I2C bus to access one of three card side busses:

1) Bus 0 – is a link to one TMP422 (sensor #5) remote temperature sensor (local temp and remote

temperatures of VSC7429 and VSC8512).

2) Bus 1 – is a direct link with XMC sites I2C system interface

3) Bus 2 – is a link to 2 TMP101 temperature sensors on the top edge (Sensor 1 and 2)

4) Bus 3 – is a link to 2 TMP101 temperature sensors on the bottom edge (Sensor 3 and 4)

*Refer to the TI TMP101 datasheet for access and setup of ALERT pin interrupt to the PCA9544. A Thermal

Alert LED is accessible on the solder side of the card if a visual indicator is required.

Reading from the I2C devices

When reading from the I2C slave interface, the last value stored in the command register by a write operation

is used to determine which command to respond to. To change the command for a read operation, a new

command must be written to the command register. This is accomplished by issuing an I2C slave address byte

with the R/W# bit LOW, followed by the command byte. The master can then generate a START condition

and send the I2C slave address byte with the R/W# bit HIGH to initiate a read command. If repeated reads

from the same register are required it is not necessary to continually send the command byte. The slave I2C

interface will remember the original command value until it is changed by the next write operation.

Example XML code to open the I2C mux and access the temperature sensors using the Totalphase Aardvark™

USB to I2C controller can be provided by request.

Page 20: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 20 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Thermal Details

Thermal Parameters

Thermal Parameter Value

Minimum Ambient Operating Temperature -40 °C

Maximum Operating Junction Temperature 125 °C

Recommended VPG TDP 15W

SoC TDP (VSC7429) 8W

PHY TDP (VSC8512) 7W

Die junction to package case top (SoC/PHY) 3.27 °C/W

Die junction to PCB (SoC/PHY) 6.03 °C/W

Die junction to Ambient (SoC/PHY) 12.14 °C/W

Die junction to moving air @ 1 m/s (SoC/PHY) 9.42 °C/W

Page 21: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 21 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

Mechanical Details

3D STEP Models A complete 3D STEP Model file of the VPX GbE Switch can be made available upon request. The VPG20x

is a Standard 3U VITA 65 unit, compliant with a 1” pitch VPX backplane layout.

Page 22: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 22 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

VPG202 Top Side View

Page 23: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 23 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

VPG202 – Bottom Side View

Page 24: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 24 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

RTM Details The main purpose of the RTG002 is to allow the ability for development in a lab environment to access all

features and GbE channels that are available on the VPG201/VPG202. The RTM is a backplane connectable

breakout board.

Page 25: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 25 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

RTG002 – Pinout Information

Photo Description

P3, J3-J10

Standard GbE RJ45 Pinouts (x16)

P1

I2C (VPX SM Bus) Header – a standard

Totalphase Aardvark™ I2C analyzer will

install without need of an adapter

Pinout

Pin 1 I2C_SCL (CLK)

Pin 2 GND

Pin 3 I2C_SDA (DATA)

P2

RJ11 Serial Interface Cable

Pinout

Pin 1 N/C

Pin 2 RX – Module Receive

Pin 3 GND

Pin 4 TX – Module Transmit

Pin 5 N/C

Pin 6 N/C

Page 26: GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch · The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from

GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch

Users Guide

www.connecttech.com

Document: CTIM-00461 Revision: 0.02

Page 26 of 26

Connect Tech Inc. 800-426-8979 | 519-836-1291

Date: 2016/10/27

RTG002 – Top Side View

RTG002 – Bottom Side View