graceport ethernet port r2r26r33r62 connector code data sheet · r3-2006-07. 5001 tremont avenue...

3

Upload: others

Post on 06-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GracePort Ethernet Port R2R26R33R62 Connector Code Data Sheet · R3-2006-07. 5001 Tremont Avenue Davenport, IA 52807 (800) 280-9517 Fax: (563) 386-9639. . R R. UL. RECOGNIZED: E207344
JLNERI
Text Box
Cross Reference RA Part Number PN-419601
JLNERI
Red_Pointed_Right
JLNERI
Typewritten Text
F 4 R 3 - T160 U39
JLNERI
Red_Pointed_Right
JLNERI
Rectangle
JLNERI
Highlight
JLNERI
Red_Pointed_Right
Page 2: GracePort Ethernet Port R2R26R33R62 Connector Code Data Sheet · R3-2006-07. 5001 Tremont Avenue Davenport, IA 52807 (800) 280-9517 Fax: (563) 386-9639. . R R. UL. RECOGNIZED: E207344

SPECIFICATIONS: MECHANICALHousing: Cast aluminum baseLatch: Type 304 Stainless Steel (1CR18NI19)Cover: Polycarbonate, UV rated, V-O Flame ratedGasket:Insert Material:

NEOPRENE/EPDM/SBR BlendAcrylic UL94HB

SPECIFICATIONS: ELECTRICALLow voltage (data), limited to 30 VDCHigh voltage supply (for computer use only)120 VAC, 15A (UL)230-240 VAC, 16A (CE only)

©200 Grace Engineered Products, Inc.GracePort is a registered Trademark of Grace Engineered Products, Inc

ThruView™ThruView™

Housings

INSTALLATION!

M 5K

--P -P -M 5B2 P1 Uxx- -

CONNECTORCODES

HOUSING/NEMA CODES

POWER OPTIONSCODES (Special text, logos,

cable lengths, MORE!)

EXCEPTION CODES

M 5K M 5-F

2

1

5

6

7

........Nema 1

........UL Type 4X

........UL Type 12

........UL Type 4X, Type 304 Stainless Steel

........UL Type 4X, Type 316 Stainless Steel

........UL Type 7-9

4

Available Enclosure Types

DataSheets:K4:8/2012

RoHS

Panel Mount Housing DimensionsUL Type 12 Rating

HOUSING CODE:

HOUSING CODE:

HOUSING CODE:

HOUSING CODE:

HOUSING CODE: M 5B 4

M 5F 4

M 5H 4

M 5K 4

M 5M 4

4

R4

5001 Tremont AvenueDavenport, IA 52807

(800) 280-9517 Fax: (563) 386-9639

www.GracePort.com

APPROVALS

ULCE

RECOGNIZED: E207344 Type 12: EN61010/EN60950 (Foreign Power Outlets)

R

GracePorts® are intended to be mounted in or on an enclosure product. Installationshould be performed by a qualified technician and adhere to applicable regulatory codes.These devices are for mounting on the flat surface of enclosures having the same typeenvironmental ratings.

®All installations

On units configured for optional AC power

:1) Cut panel opening and mount GracePort assembly to enclosure with gasket.2) Connect low voltage interface wiring according to documentation provided with unit.

:1) Connect outlet device as per code.

2) Ensure that the metal housing is reliably grounded using grounding means provided.

Note: It is the responsibility of the installer toensure adequate separation of high and low voltage circuits in the end-use product.

........UL Type 43

5-0

HousingCode

A B C D E

2.06 .010 [52.4 .2]� � 1.42 .010 [36.0 .2]� � 2.76 .004 [70.0 .1]� � 1.26 .004 [32.0 .1]� � .18 .010 [4.5 .2]+ +

3.36 .010 [85.4 .2]� � 1.42 .010 [36.0 .2]� � 4.03 .004 [102.4 .1]� � 1.26 .004 [32.0 .1]� � .18 .010 [4.6 .2]+ +

4.42 .010 [112.4 .2]� � 1.42 .010 [36.0 .2]� � 5.12 .004 [130.0 .1]� � 1.26 .004 [32.0 .1]� � .18 .010 [4.6 .2]+ +

3.39 .010 [86.0 .2]� � 2.91 .010 [74.0 .2]� � 4.41 .004 [112.0 .1]� � 2.76 .004 [70.0 .1]� � .26 .010 [6.5 .2]+ +

M 4.80 .010 [122.0 .2]� � 3.15 .010 [80.0 .2]� � 5.83 .004 [148.0 .1]� � 2.76 .004 [70.0 .1]� � .26 .010 [6.5 .2]+ +

MountingDimensionsHousing

Code(inches [mm])

B

F

H

K

F G H I J K

3.15 [80.0] 1.72 [43.6] 3.20 [81.2] 1.60 [40.7] 4.33 [110.1] .96 [24.4]

4.45 [113.0] 1.72 [43.6] 3.20 [81.2] 1.60 [40.7] 4.87 [123.7] .57 [14.4]

5.51 [140.0] 1.72 [43.6] 3.20 [81.2] 1.60 [40.7] 4.87 [123.7] .57 [14.4]

5.08 [129.0] 3.54 [90.0] 4.79 [121.6] 1.60 [40.7] 8.28 [210.2] .45 [11.4]

6.50 [165.0] 3.78 [96.0] 5.02 [127.6] 1.60 [40.7] 8.52 [216.4] .57 [14.4]

OverallDimensions(inches [mm])

Weight (oz)

3.8

5.1

5.9

10.8

13.2

Drawings available at www.graceport.com

M

K

H

F

B

L M

.45 [11.5]

.45 [11.5]

.26 .004 [6.5 .1]� �

.26 .004 [6.5 .1]� �

N/A

N/A

N/A

.18 .004 [4.5 .1]� �

.18 .004 [4.6 .1]� �

.18 .004 [4.6 .1]� �

B

D

E AC

F

G

L

MH

I J

K

8........UL Type 3R

=Diameter

JLNERI
Rectangle
JLNERI
Red_Pointed_Right
JLNERI
Rectangle
JLNERI
Red_Pointed_Up_Left
JLNERI
Rectangle
Page 3: GracePort Ethernet Port R2R26R33R62 Connector Code Data Sheet · R3-2006-07. 5001 Tremont Avenue Davenport, IA 52807 (800) 280-9517 Fax: (563) 386-9639. . R R. UL. RECOGNIZED: E207344

INSTALLATION!

GracePorts® are intended to be mounted in or on an enclosure product. Installation should be performed by a qualified technician and adhere to applicable regulatory codes.

** --P -P - -P1 R2 H 3 Uxx-

-R 3

**CONNECTORCODES

HOUSING/NEMA CODES (Special text, logos,

cable lengths, MORE!)

EXCEPTION CODES

POWER OPTIONSCODES

GracePort® Interface ProductsPower Options

Connector Code Data Sheet

AC POWER OPTIONS

If circuit protection is desired, place amperage value as a suffix to power codes shown. Example: US

duplex outlet with 3A breaker = RD3

120 VACDUPLEX

120 VACDUPLEX GFCI

120 VACSIMPLEX

INLET(male)

OUTLET(female) SWITCHED

INLET

IEC320

NORTH AMERICA

INDIAN

CONTINENTALEUROPEAN

FRENCH/BELGIAN

ITALIAN

AUSTRALIAN

BRITISH

RB

RE

RI

R

RM RP RS

RD RF

RHRA

RU

ORDERING CODES SHOWN IN RED

IF YOU DON’T

SEE WHAT

YOU NEED,

ASK US!!!

© 2006 Grace Engineered Products, Inc.GracePort® is a registered Trademark of Grace Engineered Products, Inc

R3-2006-07

5001 Tremont AvenueDavenport, IA 52807

(800) 280-9517 Fax: (563) 386-9639

www.GracePort.com

R R

UL RECOGNIZED: E207344 Type 4/4X/IP-65 (outdoor use) CSA: LR110845 (not for interrupting circuit)CE: EN61010/EN60950 (Foreign Power Outlets)

JLNERI
Rectangle
JLNERI
Red_Pointed_Right