![Page 1: GracePort Ethernet Port R2R26R33R62 Connector Code Data Sheet · R3-2006-07. 5001 Tremont Avenue Davenport, IA 52807 (800) 280-9517 Fax: (563) 386-9639. . R R. UL. RECOGNIZED: E207344](https://reader035.vdocuments.us/reader035/viewer/2022081601/610871b4a6c1a725b24544cf/html5/thumbnails/1.jpg)
![Page 2: GracePort Ethernet Port R2R26R33R62 Connector Code Data Sheet · R3-2006-07. 5001 Tremont Avenue Davenport, IA 52807 (800) 280-9517 Fax: (563) 386-9639. . R R. UL. RECOGNIZED: E207344](https://reader035.vdocuments.us/reader035/viewer/2022081601/610871b4a6c1a725b24544cf/html5/thumbnails/2.jpg)
SPECIFICATIONS: MECHANICALHousing: Cast aluminum baseLatch: Type 304 Stainless Steel (1CR18NI19)Cover: Polycarbonate, UV rated, V-O Flame ratedGasket:Insert Material:
NEOPRENE/EPDM/SBR BlendAcrylic UL94HB
SPECIFICATIONS: ELECTRICALLow voltage (data), limited to 30 VDCHigh voltage supply (for computer use only)120 VAC, 15A (UL)230-240 VAC, 16A (CE only)
©200 Grace Engineered Products, Inc.GracePort is a registered Trademark of Grace Engineered Products, Inc
7®
ThruView™ThruView™
Housings
INSTALLATION!
M 5K
--P -P -M 5B2 P1 Uxx- -
CONNECTORCODES
HOUSING/NEMA CODES
POWER OPTIONSCODES (Special text, logos,
cable lengths, MORE!)
EXCEPTION CODES
M 5K M 5-F
2
1
5
6
7
........Nema 1
........UL Type 4X
........UL Type 12
........UL Type 4X, Type 304 Stainless Steel
........UL Type 4X, Type 316 Stainless Steel
........UL Type 7-9
4
Available Enclosure Types
DataSheets:K4:8/2012
RoHS
Panel Mount Housing DimensionsUL Type 12 Rating
HOUSING CODE:
HOUSING CODE:
HOUSING CODE:
HOUSING CODE:
HOUSING CODE: M 5B 4
M 5F 4
M 5H 4
M 5K 4
M 5M 4
4
R4
5001 Tremont AvenueDavenport, IA 52807
(800) 280-9517 Fax: (563) 386-9639
www.GracePort.com
APPROVALS
ULCE
RECOGNIZED: E207344 Type 12: EN61010/EN60950 (Foreign Power Outlets)
R
GracePorts® are intended to be mounted in or on an enclosure product. Installationshould be performed by a qualified technician and adhere to applicable regulatory codes.These devices are for mounting on the flat surface of enclosures having the same typeenvironmental ratings.
®All installations
On units configured for optional AC power
:1) Cut panel opening and mount GracePort assembly to enclosure with gasket.2) Connect low voltage interface wiring according to documentation provided with unit.
:1) Connect outlet device as per code.
2) Ensure that the metal housing is reliably grounded using grounding means provided.
Note: It is the responsibility of the installer toensure adequate separation of high and low voltage circuits in the end-use product.
........UL Type 43
5-0
HousingCode
A B C D E
2.06 .010 [52.4 .2]� � 1.42 .010 [36.0 .2]� � 2.76 .004 [70.0 .1]� � 1.26 .004 [32.0 .1]� � .18 .010 [4.5 .2]+ +
3.36 .010 [85.4 .2]� � 1.42 .010 [36.0 .2]� � 4.03 .004 [102.4 .1]� � 1.26 .004 [32.0 .1]� � .18 .010 [4.6 .2]+ +
4.42 .010 [112.4 .2]� � 1.42 .010 [36.0 .2]� � 5.12 .004 [130.0 .1]� � 1.26 .004 [32.0 .1]� � .18 .010 [4.6 .2]+ +
3.39 .010 [86.0 .2]� � 2.91 .010 [74.0 .2]� � 4.41 .004 [112.0 .1]� � 2.76 .004 [70.0 .1]� � .26 .010 [6.5 .2]+ +
M 4.80 .010 [122.0 .2]� � 3.15 .010 [80.0 .2]� � 5.83 .004 [148.0 .1]� � 2.76 .004 [70.0 .1]� � .26 .010 [6.5 .2]+ +
MountingDimensionsHousing
Code(inches [mm])
B
F
H
K
F G H I J K
3.15 [80.0] 1.72 [43.6] 3.20 [81.2] 1.60 [40.7] 4.33 [110.1] .96 [24.4]
4.45 [113.0] 1.72 [43.6] 3.20 [81.2] 1.60 [40.7] 4.87 [123.7] .57 [14.4]
5.51 [140.0] 1.72 [43.6] 3.20 [81.2] 1.60 [40.7] 4.87 [123.7] .57 [14.4]
5.08 [129.0] 3.54 [90.0] 4.79 [121.6] 1.60 [40.7] 8.28 [210.2] .45 [11.4]
6.50 [165.0] 3.78 [96.0] 5.02 [127.6] 1.60 [40.7] 8.52 [216.4] .57 [14.4]
OverallDimensions(inches [mm])
Weight (oz)
3.8
5.1
5.9
10.8
13.2
Drawings available at www.graceport.com
M
K
H
F
B
L M
.45 [11.5]
.45 [11.5]
.26 .004 [6.5 .1]� �
.26 .004 [6.5 .1]� �
N/A
N/A
N/A
.18 .004 [4.5 .1]� �
.18 .004 [4.6 .1]� �
.18 .004 [4.6 .1]� �
B
D
E AC
F
G
L
MH
I J
K
8........UL Type 3R
=Diameter
![Page 3: GracePort Ethernet Port R2R26R33R62 Connector Code Data Sheet · R3-2006-07. 5001 Tremont Avenue Davenport, IA 52807 (800) 280-9517 Fax: (563) 386-9639. . R R. UL. RECOGNIZED: E207344](https://reader035.vdocuments.us/reader035/viewer/2022081601/610871b4a6c1a725b24544cf/html5/thumbnails/3.jpg)
INSTALLATION!
GracePorts® are intended to be mounted in or on an enclosure product. Installation should be performed by a qualified technician and adhere to applicable regulatory codes.
** --P -P - -P1 R2 H 3 Uxx-
-R 3
**CONNECTORCODES
HOUSING/NEMA CODES (Special text, logos,
cable lengths, MORE!)
EXCEPTION CODES
POWER OPTIONSCODES
GracePort® Interface ProductsPower Options
Connector Code Data Sheet
AC POWER OPTIONS
If circuit protection is desired, place amperage value as a suffix to power codes shown. Example: US
duplex outlet with 3A breaker = RD3
120 VACDUPLEX
120 VACDUPLEX GFCI
120 VACSIMPLEX
INLET(male)
OUTLET(female) SWITCHED
INLET
IEC320
NORTH AMERICA
INDIAN
CONTINENTALEUROPEAN
FRENCH/BELGIAN
ITALIAN
AUSTRALIAN
BRITISH
RB
RE
RI
R
RM RP RS
RD RF
RHRA
RU
ORDERING CODES SHOWN IN RED
IF YOU DON’T
SEE WHAT
YOU NEED,
ASK US!!!
© 2006 Grace Engineered Products, Inc.GracePort® is a registered Trademark of Grace Engineered Products, Inc
R3-2006-07
5001 Tremont AvenueDavenport, IA 52807
(800) 280-9517 Fax: (563) 386-9639
www.GracePort.com
R R
UL RECOGNIZED: E207344 Type 4/4X/IP-65 (outdoor use) CSA: LR110845 (not for interrupting circuit)CE: EN61010/EN60950 (Foreign Power Outlets)