going deep on plug loads - aventri · plugs alone = ~7.6 (3.1) kbtu/ft²‐yr‐with controls if...
TRANSCRIPT
5/17/2016
1
@ the Bullitt Center The Integrated Design Lab The Discovery Commons
http://www.bullittcenter.org http:/www.joelrogers.photoshelter.com http:/www.djc.om
Going Deep on Plug Loads: Strategies from the Bullitt Center12th Annual Energy/Facilities Connections (EFC) Conference4 May 2016Leavenworth, WA
Christopher Meek, AIA , IESNA Associate Professor + Director Integrated Design Lab
University of Washington Department of Architecture [email protected]
www.idlseattle.com© UW Integrated Design Lab, 2015
The Bullitt Center
- http://www.bullittcenter.org/
“The greenest commercial building in the world.”
© UW Integrated Design Lab, 2015
Image: Architectural Record
5/17/2016
2
The Bullitt FoundationThe Miller Hull Partnership
PAE EngineersSolar Design AssociatesLuma Lighting Design
The Berger PartnershipSpringline Design
DCI EngineersUW Integrated Design Lab
2020 EngineeringRDH
Point32Schuchart Construction
ClientArchitectureMechanical & ElectricalSolar Array ConsultantLightingLandscapeCivilStructuralDaylighting and Solar Shading DesignNatural Waste Treatment SystemsBuilding EnvelopeDeveloperGeneral Contractor
Design and Construction Team
5/17/2016
3
5/17/2016
4
5/17/2016
5
5/17/2016
6
Net Zero Operation: CBECS Median US Office Building
5/17/2016
7
Net Zero Operation: Seattle Energy Code Building
Net Zero Operation: LEED Platinum Building
5/17/2016
8
Net Zero Operation: Bullitt Center Design
Solar Budget: Net‐Metering
5/17/2016
9
0
100,000
200,000
300,000
400,000
500,000
600,000
700,000
SOLAR
DOMEST HOT WTR
ELEVATOR
VENTFANS
PUMPS & AUX
SPACE COOLING
SPACE HEATING
MISC EQUIP
IT SERVER
LIGHTS
The Road to Net Zero
Net‐Zero Operation
Annual Energy (kW
h)
0
100,000
200,000
300,000
400,000
500,000
600,000
700,000
SOLAR
DOMEST HOT WTR
ELEVATOR
VENTFANS
PUMPS & AUX
SPACE COOLING
SPACE HEATING
MISC EQUIP
IT SERVER
LIGHTS
The Road to Net Zero
Net‐Zero Operation
Annual Energy (kW
h)
5/17/2016
10
Ground Source Heat Pump
Heavy Timber Structure: A 250 Year Building
5/17/2016
11
Courtesy: 2020 Engineering
Water Conservation
Water and Waste Systems: rainwater harvesting and composting toilets
Modeled End‐Use Energy Distribution
© UW Integrated Design Lab, 2014
Diagram: PAE Engineering
5/17/2016
12
CBECS Climate Zone 3 Averages
Plug loads are ~ 17% on an EUI of 92 kBtu/ft²‐yr (15.6)
Plug Load Energy in NW Buildings
Office Building: Seattle Energy Code 2009 (SEC, 2009)
EUI ~42 kBtu/ft²‐yrPlug loads alone = ~12.8 kBtu/ft²‐yr
Plug Loads Consume Approx. 29%* of Seattle Energy Code Office Building Site Energy and
38% of Site Electricity (SEC, 2009)
© UW Integrated Design Lab, 2015
*This is based on modeling done in 2009 – I presume the wattage is dropping somewhat die to adoption of
more laptop computers.
5/17/2016
13
Bullitt Center
EUI ~16 kBtu/ft²‐yr (Now operating ~10 kBtu/ft²‐yr)Plugs alone = ~7.6 (3.1) kBtu/ft²‐yr‐ with controls
If plug load reduction performance is not persistent over time the project will not meet net‐zero operation.
© UW Integrated Design Lab, 2015
Plug Load Energy in NW Buildings
Office Building: Seattle Energy Code 2009 (SEC, 2009)
EUI ~42 kBtu/ft²‐yrPlug loads alone = ~12.8 kBtu/ft²‐yr
Plug Loads Consume Approx. 29%* of Seattle Energy Code Office Building Site Energy and
38% of Site Electricity (SEC, 2009)
5/17/2016
14
Daylighting!
5/17/2016
15
5/17/2016
16
© UW Integrated Design Lab, 2015
5/17/2016
17
5/17/2016
18
“Tenant Engagement” (Office Equipt. Plug Loads)
5/17/2016
19
Energy Conservation Measures
TYPICAL BUILDING
With ENERGY
CONSERVATION
With OCCUPANT
ENGAGEMENT
DESIGN = 38%
DESIGN + PEOPLE= 70%
5/17/2016
20
Green Lease at Bullitt Center
• Many provisions…• Includes tenant energy budget apportioned by
square footage of leased area.
© UW Integrated Design Lab, 2015
UW Leased Area: 7950 ft²Annual Energy budget: 5452 kWh
Plug Load Energy Allocation Density: 0.69 kWh/ft²Plug Load “Density” @ 2000 hrs: 0.345 W/ft² (whole building)@ 200 ft²/person: ~70 W/workstation
Office Plug Load Survey: Workstations
5/17/2016
21
Office Plug Load Survey: Copy Room
Office Plug Load Survey: Kitchen
5/17/2016
22
Monitors Computer
2 – 20” CFL-LCD 1 - Desktop@ 75 Watts each @ 100 Watts
2 – 22” LED-LCD 1 - Desktop@ 40 Watts each @ 80 Watts160 watts
2 – 22” LED-LCD 1 - Laptop@ 14 Watts each @ 62 Watts90 watts
Work Station Efficienciestypical
good (2009)
better (2010)
250 watts
Graphic: PAE Engineering
14watts
14watts
42 watts
22” LED-LCD
14watts
22” LED-LCD
Thin‐client Workstation
5/17/2016
23
Smart Plug Strips
control: switches and sensorsmeter: plugs and lights monitor: visualize and inform
Image: Enmetric Plug Load Manager/UW IDL
Comprehensive Plug‐Load/Task Lighting Management
Web‐based Real Time Plug Load Data Collection, Scheduling, and Reporting at Each Receptacle.
© UW Integrated Design Lab, 2014
5/17/2016
24
Enmetric Plugstripshttps://prod.enmetric.com/Username: [email protected]: idl@enm
Live Demo*
* fingers crossed
M&V and Occupant FeedbackOccupant Feedback and Energy Performance Documentation
© UW Integrated Design Lab, 2015
5/17/2016
25
Predicted vs. ActualBullitt Center Performance
-40,000
-30,000
-20,000
-10,000
0
10,000
20,000
30,000
40,000
50,000
60,000
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug
Elec
tric
Con
sum
ptio
n, k
Wh
Bullitt Center PerformanceActuals, 10/1/15
SCL Power Used PV Exported to SCL PV Used by BullittSavings over Baseline Bullitt Building Use Est. Code BaselineSCL Net Meter - SVC 4 Proposed Tenant Building
Graph: PAE Engineering
Thank you!
Christopher Meek, AIA, IESAssociate Professor and Director Integrated Design Lab
University of Washington Department of Architecture [email protected] www.idlseattle.com
© UW Integrated Design Lab, 2015
5/17/2016
26
Dynamic Solar Shading: Glare Control and Daylight Persistence Measure
Baseline Windows Automated Exterior Blinds
© UW Integrated Design Lab, 2015
5/17/2016
27
Dynamic Luminance Map: Automated Blinds Deployment© UW Integrated Design Lab, 2015