goals 1.reduce inventory 25% 2.improve productivity 25% 3.create standard operations september 15-...
TRANSCRIPT
Goals
1. Reduce inventory 25%
2. Improve productivity 25%
3. Create Standard Operations
September 15- 19, 2005
Quality Control Lab
Kaizen Event
Takt Time Chart
0
100
200
300
400
500
600
700
800
Denier Instron Coherency Thermal Shrinkage
Se
co
nd
s
Manual
Auto
Takt Time = 620 minutes = 525 seconds 71 Tests
Trial Setup
Denier
Coherency
Instron
T.S.
WIPWIPWIPWIP
Material FlowExit
Operator OneOperator Two
Operator 3
Summary of AchievementMeasure Before After Improvement
Operators per Shift 5 4 20%
Inventory 65 34 42%
Movement per Test 320 ft 60 ft 81%
Tests per Shift 42 61 31%
Equipment Used 14 10 29%
Material Flow Intersecting, colliding
One direction, flow
Goal is 71
Trial Results
0
2
4
6
8
10
12
14
Test 1 Test 2 Test 3 Test 4 Test 5 Test 6 Test 7 Test 8
Min
ute
s
Above Takt Time- Computer issue
Above Takt Time- Computer issue
Computer issues disrupt ability to meet Takt Time
TAKT TIME
Six Sigma: Reducing Variation• Network too slow• Re-Test procedure causing extra tests• Eliminated unnecessary test• Mistake-proofed sample log screens • Coached adherence to standard operations
across all four shifts• Separated log screens to minimize file
open/close time
Achieved Target of 71 Tests!
Define and Measure
CharterDefined defect as
broken filamentHigh level process
mapDetailed Quality MapGage R & R on
measurement systems
Fish bone diagram to determine cause and effect
Difficulty impact matrix
Process CapabilityComparative Analysis
Visual Inspection Gage R & R ResultsWithin Appraisers
Assessment Agreement
Appraiser # Inspected # Matched Percent 95 % CIBrenda 32 25 78.13 (60.03, 90.72)Vic 32 23 71.88 (53.25, 86.25)Chris 32 23 71.88 (53.25, 86.25)Katrina 32 24 75.00 (56.60, 88.54)Edgar 32 24 75.00 (56.60, 88.54)Sue 32 10 31.25 (16.12, 50.01)
# Matched: Appraiser agrees with him/herself across trials
Repeatability
Goal should be > 90% correct decisions!
Between Appraisers
Assessment Agreement
# Inspected # Matched Percent 95 % CI 32 7 21.88 (9.28, 39.97)
# Matched: All appraisers' assessments agree with each other.
Reproducibility
Visual Inspection Gage R & R Results
• No operators met the gage R&R goal of 90%
• Visual expert was only 62% repeatable!
• Completed parallel study using automated defect counter
• Gage results met 90% goal
Through MSA, determined good product was labeled defective.