geotech 1.66” auto-reclaimer€¦ · reclaimer requires only a regulated compressed air source to...

24
Rev 10/19/12 Part # 16600165 Geotech 1.66” Auto-Reclaimer Installation and Operation

Upload: others

Post on 05-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

Rev 10/19/12 Part # 16600165

Geotech 1.66” Auto-Reclaimer

Installation and Operation

Page 2: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above
Page 3: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

1

TABLE OF CONTENTS

CHAPTER 1: SYSTEM DESCRIPTION ............................................................... 3

FUNCTION AND THEORY ....................................................................................... 3 SYSTEM COMPONENTS ........................................................................................ 4

CHAPTER 2: SYSTEM INSTALLATION ............................................................. 5

TOP FILL ............................................................................................................. 5 BOTTOM FILL ....................................................................................................... 5 DUAL FILL ........................................................................................................... 7

CHAPTER 3: SYSTEM OPERATION .................................................................. 8

TOP FILL ............................................................................................................. 8 BOTTOM FILL ....................................................................................................... 8 DUAL FILL ........................................................................................................... 9

CHAPTER 4: SYSTEM MAINTENANCE ........................................................... 12

CHAPTER 5: SYSTEM TROUBLESHOOTING................................................. 13

CHAPTER 6: SYSTEM SPECIFICATIONS ....................................................... 14

CHAPTER 7: REPLACEMENT PARTS LIST.................................................... 19

THE WARRANTY ................................................................................................ 20

EQUIPMENT RETURN POLICY ......................................................................... 20

EQUIPMENT DECONTAMINATION ................................................................... 20

Page 4: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

2

DOCUMENTATION CONVENTIONS

This manual uses the following conventions to present information:

An exclamation point icon indicates a WARNING of a situation or condition that could lead to personal injury or death. You should not proceed until you read and

thoroughly understand the WARNING message.

A raised hand icon indicates CAUTION information that relates to a situation or condition that could lead to equipment malfunction or damage. You should not proceed until you read and thoroughly understand the CAUTION message.

A note icon indicates NOTE information. Notes provide additional or supplementary information about an activity or concept.

WARNING

CAUTION

NOTES

Page 5: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

3

Chapter 1: System Description

Function and Theory

The GEOTECH 1.66" Auto-Reclaimer top fill, bottom fill, or top/bottom fill system is a fixed intake, automatic total fluids recovery pump. The 1.66" Auto-Reclaimer will recover fluids from depths of up to 250 ft. The GEOTECH Auto-Reclaimer is an automatic and controllerless, positive air-displacement pump. The Auto-Reclaimer works without the use of any external controls, relays, bleeder tubes or bubblers. The Auto-Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above static head. The Auto-Reclaimer does not require clean, dry air to function properly, and can operate on contaminated or industrial air. The GEOTECH Auto-Reclaimer can operate under both positive and *negative (vacuum) pressure environments. The Auto-Reclaimer self-adjusts the discharge flow rate automatically to match individual well recharge rates (up to the pumps maximum capacity).

The Auto-Reclaimer will pump large particulates up to 1/16" in diameter without problems. The unique single self-cleaning valve mechanism will pass high viscosity gear oils without fouling.

* Vacuum conditions may require a Vacuum Equalizer if venting out of the recovery well. Contact your technical sales representative for more information.

Page 6: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

4

System Components

The GEOTECH Auto-Reclaimer system components consist of an Upper Head Valve Assembly, Internal Float Assembly, Bottom Intake Assembly (for Bottom Fill, Top/Bottom Fill), and a Top Fill Intake Screen Assembly (for Top and Dual Fill Models)

Upper Screened Intake Assembly

(Top / Dual Fill Models)

Upper Head Valve Assembly Pump Housing

Internal Float Assembly

Bottom Plug (Top Fill Model)

Bottom Intake (Bottom / Dual Fill Models)

Figure 1

Fluid Discharge Assembly

Control Rod

Center Pipe

Page 7: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

5

Chapter 2: System Installation

Top Fill

Attach the hoses to the proper barbed fittings (see figure 2, page 7). Ensure that all hoses are installed securely and completely (Fluid intake assembly not shown).

Ensure the eyebolt is threaded all the way to the fixed jam nut, and is securely tightened.

Attach the pump hanging cable to the eyebolt; ensuring attachment method is secure and tight. The Auto-Reclaimer can now be lowered into the recovery well. The top fill Auto-Reclaimer is initially lowered into the well where the top inlet is submerged below static groundwater conditions. This allows floating product to enter through the top inlet to fill the housing and be pumped to the surface (see figure 3, page 11).

Bottom Fill

Attach the air inlet, product discharge, and the air exhaust hoses to the proper barbed fittings (see figure 2, page 7).

Attach the pump hanging cable to the eyebolt; ensuring attachment method is secure and tight. The Auto-Reclaimer can now be lowered into the recovery well. The bottom fill Auto-Reclaimer is initially lowered into the well where the bottom inlet is submerged well below static groundwater conditions (see figure 4, page 12.

Ensure the eyebolt is threaded all the way to the

fixed jam nut, and is securely tightened.

Page 8: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

6

Figure 2

Fluid Discharge

Air Supply

Air Exhaust (Vent)

Hanger Eyebolt

Page 9: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

7

Dual Fill

Attach the hoses to the proper barbed fittings (see figure 2, page 7). Ensure that all hoses are installed securely and completely. Ensure the eyebolt is threaded all the way to the fixed jam nut, and securely tightened. Attach the pump hanging cable to the eyebolt; ensuring attachment method is secure and tight. The Auto-Reclaimer can now be lowered into the recovery well. The Dual (top / bottom) fill Auto-Reclaimer is initially lowered into the well where the top inlet is submerged below static groundwater conditions. This allows floating product to enter through both the top and bottom inlets to fill the housing and be pumped to the surface.

Page 10: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

8

Chapter 3: System Operation

Compressed air is utilized in this system as an on

demand supply. Typically, .5 cubic foot of air is

necessary per gallon of liquid pumped.

Top Fill

The Auto-Reclaimer is placed in a recovery well with the top inlet submerged below static groundwater. Provided with a regulated air supply, the Auto-Reclaimer cyclically fills and empties. As the pump fills, the internal float assembly rises until it comes in contact with an upper stop that is connected to a mechanical rocker assembly. The rocker assembly shifts and simultaneously opens the air supply valve. The resulting effect is air pressure builds within the pump housing and displaces the fluids up and out of the pump through the discharge ball check valve. As the pump discharge cycle progresses, the float assembly falls. The float assembly contacts the lower stop, which triggers the rocker assembly, again shifting, thus closing the air supply valve and opening the air exhaust valve. The pressurized air exits out of the air exhaust tube, allowing the pump to refill and begin a new cycle. This cyclic operation continues automatically as fluid is drawn into the well.

Bottom Fill

The Bottom Fill Auto-Reclaimer is placed in a recovery well with the bottom intake submerged below static groundwater. Provided with a regulated air supply, the Auto-Reclaimer cyclically fills and empties. As the pump fills, the internal float assembly rises until it comes in contact with an upper stop that is connected to a mechanical rocker assembly. The rocker assembly shifts and simultaneously opens the air supply valve. The resulting effect is air pressure builds within the pump housing and displaces the fluids up and out of the pump through the discharge ball check valve. As the pump discharge cycle progresses, the float assembly falls. The float assembly contacts the lower stop, which

Page 11: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

9

triggers the rocker assembly, again shifting, thus closing the air supply valve and opening the air exhaust valve. The pressurized air exits out of the air exhaust tube, allowing the pump to refill and begin a new cycle. This cyclic operation continues automatically as fluid is drawn into the well. The Auto-Reclaimer will ultimately catch up to the recharge rate of the well, (see specifications section, maximum flow rate). The fluid level will be maintained at the minimum activation level (see specifications), and the Auto-Reclaimer will pump at the rate equal to the recharge rate of the well.

Dual Fill

The Top/Bottom fill Auto-Reclaimer is placed in a recovery well with the top inlet submerged below static groundwater. Provided with a regulated air supply, the Auto-Reclaimer cyclically fills and empties. As the pump fills, the internal float assembly rises until it comes in contact with an upper stop that is connected to a mechanical rocker assembly. The rocker assembly shifts and simultaneously opens the air supply valve. The resulting effect is air pressure builds within the pump housing and displaces the fluids up and out of the pump through the discharge ball check valve. As the pump discharge cycle progresses, the float assembly falls. The float assembly contacts the lower stop, which triggers the rocker assembly, again shifting, thus closing the air supply valve and opening the air exhaust valve. The pressurized air exits out of the air exhaust tube, allowing the pump to refill and begin a new cycle. This cyclic operation continues automatically as fluid is drawn into the well.

Page 12: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

10

Figure 3

Page 13: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

11

Figure 4

Page 14: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

12

Chapter 4: System Maintenance

Maintenance Procedures Every 3-4 months or when deemed necessary, depending on fluids being pumped, the Auto-Reclaimer should be removed from the well and cleaned inside and out. This may be accomplished using an industrial cleaner, such as phosphate free detergent or Simple Green. The following areas should be examined: Float Assembly - Check for loose screws on float plates. Compression Springs - Check for proper spring geometry. Air Pressure Valve - Verify gap, adjust if necessary. Exhaust Valve - Verify gap, adjust if necessary. O-Rings - Visually inspect for damage. Stop Collar - Verify location distance from female spring guide (see figure below).

Figure 5

Pump does not require clean dry air to operate. However, using dirty particulate filled air will increase maintenance frequency.

Page 15: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

13

Chapter 5: System Troubleshooting

Problem: Pump does not discharge fluid to the surface. Solutions: 1) Ensure air pressure is adequate enough. –

(See specifications section, min operating pressure example: .43 psi per ft. of static head pressure)

2) Inlet screen is clogged –

Clean screen 3) Inlet pipe plug is clogged –

Clear, Clean plug 4) Air exhaust vent hose is clogged –

Clear vent hose 5) Hoses are kinked or cut –

Replace hoses

Page 16: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

14

Chapter 6: System Specifications

48

” G

EO

TE

CH

1

.6

6 A

UT

O-R

EC

LA

IM

ER

ST

AIN

LE

SS

ST

EE

L,

PT

FE

, A

ce

tal, V

ITO

N

ST

AIN

LE

SS

ST

EE

L

48

” B

OT

TO

M L

OA

DIN

G

FIX

ED

IN

TA

KE

CO

NT

RO

LL

ER

LE

SS

PO

SIT

IVE

AIR

DIS

PL

AC

EM

EN

T

1.6

6 in.

(4.2

2cm

.)

54

.7 in.

(13

9.0

cm

.)

9.5

lbs.

(4.3

kg

.)

25

0 f

t. (

15

2.4

m.)

2.0

in

. (5

.08

cm

.)

5-2

75

psi. (

.3-1

8.9

ba

r)

1 p

si. (

.07 b

ar)

ab

ove s

tatic h

ea

d

.4-1

.3 s

cf /

ga

l (3

.0 /

9.7

lite

rs a

ir/lite

rs (

flu

id)

(se

e a

ir c

on

su

mp

tion

cu

rve)

.7 S

pG

(g

r/cc)

.11

ga

l. (

.42

lite

rs)

3.0

0 g

pm

. (1

1.3

6 lpm

.) @

20

ft.

2

.75

gp

m. (1

0.4

1 lpm

.) @

20

ft.

s

ub

merg

en

ce @

100

psi

su

bm

erg

en

ce

@ 1

00

psi

38

.0 in.

(96

.5cm

.)

3

8.0

in

. (9

6.5

cm

.)

ST

AIN

LE

SS

ST

EE

L (

BA

RB

TY

PE

)

1/2

" X

3/8

” M

PT

1/4

” X

1/8

” M

PT

1/4

” X

1/8

” M

PT

22

F T

OP

TE

MP

ER

AT

UR

E F

OR

HD

PE

48

” D

UA

L (

TO

P /

BO

TT

OM

LO

AD

ING

FIX

ED

IN

TA

KE

CO

NT

RO

LL

ER

LE

SS

PO

SIT

IVE

AIR

DIS

PL

AC

EM

EN

T

1.6

6 in.

(4.2

2cm

.)

56

.3 in.

(14

3.0

cm

.)

10

lb

s.

(4.5

kg

.)

25

0 f

t. (

15

2.4

m.)

2.0

in

. (5

.08

cm

.)

CO

NS

TR

UC

TIO

N M

AT

ER

IAL

S

HO

US

ING

MA

TE

RIA

L

CO

NF

IGU

RA

TIO

N

PU

MP

TY

PE

OU

TS

IDE

DIA

ME

TE

R

LE

NG

TH

WE

IGH

T

MA

X.

RA

TE

D D

EP

TH

MIN

. W

EL

L I

D

OP

ER

AT

ING

PR

ES

SU

RE

R

AN

GE

MIN

. O

PE

RA

TIN

G P

RE

SS

UR

E

AIR

CO

NS

UM

PT

ION

MIN

. L

IQU

ID D

EN

SIT

Y

VO

LU

ME

/ C

YC

LE

MA

XIM

UM

FL

OW

RA

TE

MIN

IMU

M A

CT

IVA

TIO

N L

EV

EL

FIT

TIN

GS

HO

SE

SIZ

ES

FL

UID

DIS

CH

AR

GE

AIR

SU

PP

LY

AIR

EX

HA

US

T

TE

MP

ER

AT

UR

E S

PE

CIF

ICA

TIO

NS

Figure 6

Page 17: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

15

Figure 7

GE

OT

EC

H 1

.66 A

UT

O-R

EC

LA

IME

R4

8"

To

p L

oa

din

g F

ixe

d I

nta

ke

(1/2

" ID

Flu

id D

isc

ha

rge

Ho

se

)

0.0

0

0.2

0

0.4

0

0.6

0

0.8

0

1.0

0

1.2

0

1.4

0

1.6

0

02

55

07

51

00

12

51

50

17

52

00

22

52

50

PU

MP

DE

PT

H (

FT

)

GPM

48”

GE

OT

EC

H 1

.66 A

UT

O-R

EC

LA

IME

R

ALL C

ALC

UL

AT

ION

S B

AS

ED

ON

MO

DE

L G

EO

1.6

6

W / M

INIM

UM

10’ S

UB

ME

RG

EN

CE

OF

PU

MP

HE

AD

48”

TO

P L

OA

DIN

G F

IXE

D I

NT

AK

E

(1/2

” ID

Flu

id D

ischarg

e H

ose)

NO

TE

:

SP

EC

IFIC

GR

AV

ITY

AN

D V

ISC

OS

ITY

WIL

L A

LT

ER

LIS

TE

D S

PE

CIF

ICA

TIO

NS

45 P

SI

70 P

SI

100 P

SI

Page 18: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

16

Figure 8

0.0

0

0.5

0

1.0

0

1.5

0

2.0

0

2.5

0

02

55

07

51

00

12

51

50

17

52

00

22

52

50

PU

MP

DE

PT

H (

FT

)

GPM

48”

GE

OT

EC

H 1

.66 A

UT

O-R

EC

LA

IME

R

ALL C

ALC

UL

AT

ION

S B

AS

ED

ON

MO

DE

L G

EO

1.6

6

W / M

INIM

UM

10’ S

UB

ME

RG

EN

CE

OF

PU

MP

HE

AD

48”

BO

TT

OM

LO

AD

ING

FIX

ED

IN

TA

KE

(1/2

” ID

Flu

id D

ischarg

e H

ose)

45 P

SI

70 P

SI

100 P

SI

NO

TE

:

SP

EC

IFIC

GR

AV

ITY

AN

D V

ISC

OS

ITY

WIL

L A

LT

ER

LIS

TE

D S

PE

CIF

ICA

TIO

NS

Page 19: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

17

Figure 9

GE

OT

EC

H 1

.66 A

UT

O-R

EC

LA

IME

R4

8"

Du

al

Lo

ad

ing

Fix

ed

In

tak

e(1

/2" ID

Flu

id D

isc

ha

rge

Ho

se

)

0.0

0

0.5

0

1.0

0

1.5

0

2.0

0

2.5

0

3.0

0

02

55

07

51

00

12

51

50

17

52

00

22

52

50

de

pth

GPM

48”

GE

OT

EC

H 1

.66 A

UT

O-R

EC

LA

IME

R

ALL C

ALC

UL

AT

ION

S B

AS

ED

ON

MO

DE

L G

EO

1.6

6

W / M

INIM

UM

10’ S

UB

ME

RG

EN

CE

OF

PU

MP

HE

AD

48”

DU

AL L

OA

DIN

G F

IXE

D IN

TA

KE

(1/2

” ID

Flu

id D

ischa

rge H

ose)

45 P

SI

70 P

SI

100 P

SI

NO

TE

:

SP

EC

IFIC

GR

AV

ITY

AN

D V

ISC

OS

ITY

WIL

L A

LT

ER

LIS

TE

D S

PE

CIF

ICA

TIO

NS

Page 20: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

18

Figure 10

48"G

EO

TEC

H 1

.66 A

UT

O-R

EC

LA

IMER

AIR

CO

NS

UM

PT

ION

CU

RV

ES

1/2

" ID

FL

UID

DIS

CH

AR

GE H

OS

E

0.0

00

0.2

00

0.4

00

0.6

00

0.8

00

1.0

00

1.2

00

1.4

00

025

50

75

100

125

150

175

200

225

250

DEP

TH

OF P

UM

P IN

WEL

L

MA

XIM

UM

AIR

US

E IN

ST

AN

DA

RD

CU

BIC

FEET

(SC

F)

PER

GA

LL

ON

PU

MP

ED

SCF/gal

45 p

si

70 p

si

100 p

si

48”

GE

OT

EC

H 1

.66 A

UT

O-R

EC

LA

IME

R

AIR

CO

NS

UM

PT

ION

CU

RV

ES

1/2

” ID

FLU

ID D

ISC

HA

RG

E H

OS

E

DE

PT

H O

F P

UM

P I

N W

EL

L

MA

XIM

UM

AIR

US

E IN

ST

AN

DA

RD

CU

BIC

FE

ET

(SC

F)

PE

R G

ALLO

N P

UM

PE

D

45 P

SI

70 P

SI

100 P

SI

Page 21: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

19

Chapter 7: Replacement Parts List

Parts List Parts Description 11150019 Ball, SS6 16600110 Spring, Compression, SS6 16600133 F, Bolt, Eye, SS4 16600160 Set Screw, Dog PT. 17200072 F, Hosebarb, SS6 (Air) 17200072 F, Hosebarb, SS6 (Vent) 17500082 Ball, SS6 17500084 Ball, TFE 26600036 Lower Stop 26600061 Housing, Outer, SS, 1.66 Auto 26600071 Head, Bottom Inlet, 1.66B Auto 26600072 Cap, Bottom Inlet, 1.66B Auto 26600078 Seat, Pres Valve, SS, 1.66 Auto 26600079 Seat, Vent Valve, SS, 1.66 Auto 26600083 Screen, Inlet, SS, 1.66 Auto 26600084 Hosebarb, SS, 1/2” x 3/8” MPT (Discharge) 26600086 Rod, Control, SS4, 1.66 Auto 48” 26600130 Stop Collar 56600025 Assy, Float, 1.66 Auto 16600165 Manual

Page 22: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

20

The Warranty

For a period of one (1) year from date of first sale, product is warranted to be free from defects in materials and workmanship. Geotech agrees to repair or replace, at Geotech’s option, the portion proving defective, or at Geotech’s option to refund the purchase price thereof. Geotech will have no warranty obligation if the product is subjected to abnormal operating conditions, accident, abuse, misuse, unauthorized modification, alteration, repair, or replacement of wear parts. User assumes all other risk, if any, including the risk of injury, loss, or damage, direct or consequential, arising out of the use, misuse, or inability to use this product. User agrees to use, maintain and install product in accordance with recommendations and instructions. User is responsible for transportation charges connected to the repair or replacement of product under this warranty.

Equipment Return Policy

A Return Material Authorization number (RMA #) is required prior to return of any equipment to our facilities, please call 800 number for appropriate location. An RMA # will be issued upon receipt of your request to return equipment, which should include reasons for the return. Your return shipment to us must have this RMA # clearly marked on the outside of the package. Proof of date of purchase is required for processing of all warranty requests. This policy applies to both equipment sales and repair orders. FOR A RETURN MATERIAL AUTHORIZATION, PLEASE CALL OUR SERVICE DEPARTMENT AT 1-800-833-7958 Model Number: ________________ Serial Number: ________________ Date: ________________

Equipment Decontamination

Prior to return, all equipment must be thoroughly cleaned and decontaminated. Please make note on RMA form, the use of equipment, contaminants equipment was exposed to, and decontamination solutions/methods used. Geotech reserves the right to refuse any equipment not properly decontaminated. Geotech may also choose to decontaminate equipment for a fee, which will be applied to the repair order invoice.

Page 23: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above
Page 24: Geotech 1.66” Auto-Reclaimer€¦ · Reclaimer requires only a regulated compressed air source to operate. The Auto-Reclaimer requires an operating pressure of only 1 PSI above

Geotech Environmental Equipment, Inc

2650 East 40th

Avenue Denver, Colorado 80205

(303) 320-4764 ● (800) 833-7958 ● FAX (303) 322-7242

email: [email protected] website: www.geotechenv.com