genready load center and transfer switch load center.pdffront cover & door. 43.25. generator...
TRANSCRIPT
• 200amp
• 40circuitcapacitywiththeuseoftandembreakers
• MultilistedforusewithSiemens,SquareDandGE1”breakers
• Dimensionsarethesameasastandard42-spacemainloadcenter
• UtilizesstandardSiemenscomponents
• Protectupto18circuits,upto30withtheuseoftandembreakers
• 10circuitsavailablefornon-protectedloads
• Circuitscaneasilybeshiftedfromprotectedtonon-protectedandviceversa
• ETLlistedforserviceequipmentandconsumersafety
• ModelsavailablewithorwithoutEZTransferOperator™factoryinstalled
• Singlepanelsarecompatiblewithgeneratorsratedupto125Amps/30kW
• MultipleGenReadyloadcenterscanbesupportedwithasinglegenerator
• FlushMountNEMA1EnclosureorNEMA3REnclosure
GENREADY™ LOAD CENTER FEATURES
DESCRIPTIONThe GenReady load center is a hybrid panel that operates as a normal load center and also allows for seamless integration of standby generators. It is available in a NEMA 1 configuration for indoor installations, or in a NEMA 3R configuration for outdoor applications. For installation flexibility, it is multi-listed for use with multiple breaker manufacturers.
EZ TRANSFER™ OPERATOR FEATURES• FactoryinstalledontheGenReadyAdvancedmodel.CanbeeasilyinstalledinthefieldontheGenReadyBasicwithavailablekit
• Allowsformanualorautomaticoperation
Please Note: The GenReady Panel is designed to be directly compatible with any Generac manufactured product. Use of another manufacturer’s generator may require the purchase and installation of additional sensing and control components.
Model 005448-2 (NEMA 1 Basic)Model 005449-2 (NEMA 1 Advanced)Model 005453-2 (NEMA 3R Basic)Model 005454-2 (NEMA 3R Advanced)Model 005447-0 (EZ Transfer Operator™)
GENERAC® TRANSFER SWITCH™
GenReady® Load Center and Transfer Switch
®
PRODUCT OPTIONS
NEMA1GenReadyBasicLoadCenter
Model Number 5448
NEMA1GenReadyAdvancedLoadCenterwithEZ
TransferOperator™Model Number 5449
NEMA3RGenReadyAdvancedLoadCenterwithEZ
TransferOperator™Model Number 5454
EZTransferOperator™FieldInstallationKit
Model Number 5447
Includes:
•125ACircuitBreaker
•125ALowerPanelCircuitSwitch
•200AMainCircuitBreaker
IncludesGenReadyBasicplus:
•EZTransferOperator™
•125ALowerPanel,GeneratorCircuitSwitch
•15ADoublePoleBreakerforSensingCircuit
•Plusallothercomponentsfoundinthefieldinstallationkit.
IncludesGenReadyBasicplus:
•EZTransferOperator™
•125ALowerPanel,GeneratorCircuitSwitch
•15ADoublePoleBreakerforSensingCircuit
•Plusallothercomponentsfoundinthefieldinstallationkit.
TransferOperatorFieldInstallationKitIncludes:
•TransferOperator
•15ADoublePoleBreakerforGeneratorSensingCircuit
•125ALowerPanel,GeneratorCircuitSwitch
•HoldDownBracket
•InterlockBar
•MountingHardware
•Decals
•InstallationGuide
GenReady™ Load Center and Transfer Switch
UNIT DIMENSIONS
14.38
42
Outside Dimensions of Enclosure Shell
15.63
4
Front Cover&
Door
43.25
Generator
Utility
Transfer Operator
Neutral
EquipmentGround
Bonding Connection
14.875
14.38
42
Outside Dimensions of Enclosure Shell
4.5
5
NEMA 1 NEMA 3R
GenReady™ Load Center and Transfer Switch
SPECIFICATIONSEnclosure............................................................................ NEMAType1,orNEMA3R,galvanizedG90steelw/polyesterpowdercoat
MainBreaker.......................................................................................................................................................................... 200Amp
GeneratorSwitch.................................................................................................................................................................... 125Amp
Mainbreakerwiresize........................................................................................................................................#1to300mcmCu-Al
Generatorswitchwiresize..............................................................................................................................#2to1/0Cu,1/0-2/0Al
NeutralLug.................................................................................................................................................................. #6to300mcm
GroundLug.............................................................................................................................................................................#14-2/0
Maximumnumberofcircuits
(standard1"breakers/tandembreakers)
Protectedcircuits...................................................................................................................................................................... 18/30
Non-protectedcircuits...............................................................................................................................................................10/NA
Totalcircuits.............................................................................................................................................................................. 28/40
WithstandratingMainbus(amps)............................................................................................................................................... 10,000
MeetsNECwirebendingspace......................................................................................................................................................... Yes
ETLlisted.......................................................................................................................................................................................... Yes
SeismicallyqualifiedtomeetUBCcode............................................................................................................................................. Yes
Weight–GenReadyBasicw/oEZtransferoperator
(GenReadyAdvancedwithEZtransferoperator)..........................................................................................................45.5lbs.(49lbs.)
Operatingtemperaturerange......................................................................................................................................... -20ºFto140ºF
GeneracPowerSystems,Inc.•S45W29290HWY.59,Waukesha,WI53189•generac.com©2011GeneracPowerSystems,Inc.Allrightsreserved.Allspecificationsaresubjecttochangewithoutnotice.Bulletin0175200SBY-H/PrintedinU.S.A.05/17/11
GenReadyBasic GenReadyAdvanced GenReadyComplete
TheGenReadyloadcenterisinstalledwith-outtheEZTransferOperator™.Itreplacesthehome’smainloadcenter.Thisoptionwillsavethehomeownerthousandsinupgradecostswhenageneratorisinstalled.
TheGenReadyloadcenterisinstalledwiththeEZTransferOperator™.Allfuelandelec-tricallines(contractorsupplied)areinstalledtotheplannedgeneratorsitealongwiththegeneratorpad(ifrequired).Thehomeiscompletelywiredandreadyfortheadditionofageneratorinthefuture.
EverythingincludedintheGenReadyAdvancedlevelisinstalledalongwithanautomaticstandbygenerator.Thehome’sselectedcircuitswillbebackedupbygen-eratorpowerwhenevertheutilityislost.
INSTALLATION OPTIONS
TheNEMA3RGenReadyinstallationissimilarbutissuitableforoutdoorinstallations.
®
GenReady™ Load Center and Transfer Switch