genex probe v100r005c01b050 release notes
TRANSCRIPT
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
1/26
GENEX Probe
V100R005C01B050
Release Notes
Issue 01
Date 2009-03-30
HUAWEI TECHNOLOGIES CO., LTD.
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
2/26
Copyright Huawei Technologies Co., Ltd. 2009. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The information in this document is subject to change without notice. Every effort has been made in the preparation
of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this
document do not constitute the warranty of any kind, express or implied.
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. Please feel
free to contact our local office or company headquarters.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: [email protected]
http://www.huawei.com/mailto:[email protected]://www.huawei.com/mailto:[email protected] -
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
3/26
GENEX ProbeV100R005C01B050
Release Notes About This DocumentContents
About This Document
Arthur
Preparedby
Wang Libo Date 2009-03-30
Reviewedby
Yu Yongxian, Rao Bo, Zhou Guohui, Qiu Rongzhong, Yue
Aiju, Wang Runting, Wang Yongchao
Date 2009-03-30
Tested by Sun Qianran, Li Yang Date 2009-03-30
Approvedby
Guo zhihong Date 2009-03-30
Organization
This document describes the changes in the GENEX Probe V100R005C01B050.
You need to read this document carefully before using the GENEX ProbeV100R005C01B050.This document consists of seven chapters and is organized as follows.
Chapter Description
1Version Mapping Provides the versions of the products and softwareconfigured for this release.
2Version Compatibility Describes the compatibility with earlier product versions.
3Version Changes Describes the changes in features.
4V100R005C01 Features Describes the features of V100R005C01.
5Solved Problems and
Unsolved Problems
Describes the solved problems and unsolved problems.
6Precautions Describes the precautions for this release.
7Related Documents Describes how to obtain related documents.
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
iii
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
4/26
About This Document
GENEX ProbeV100R005C01B050
Release Notes
Contents
1 Version Mapping............................................................................1
1.1 Product Version........................................................................................................................................................1
1.2 Software Versions................................................................................................................................................ ....1
1.3 Related Product Versions.........................................................................................................................................1
1.4 Versions of the OS and Database.............................................................................................................................2
2 Version Compatibility.....................................................................1
2.1 Compatibility with Earlier Product Versions...........................................................................................................1
3 Version Changes.............................................................................1
3.1 Changes from V100R005C01B040 to V100R005C01B050.................................................................................. .1
3.1.1 Feature Changes................................................................................................................................. ........ .......1
3.1.2 GUI Changes........................................................................................................................................... ......... .6
4 V100R005C01 Features..................................................................1
5 Solved Problems and Unsolved Problems.........................................1
5.1 Solved Problems......................................................................................................................................................1
5.1.1 Improvements of V100R005C01B050 on V100R005C01B040............................................................... ........1
5.2 Unsolved Problems................................................................................................................................................. .8
6 Precautions...................................................................................1
7 Related Documents........................................................................1
Figure 1.1 Acronyms and Abbreviations..............................................1
Figure 1.1 Acronyms and Abbreviations..............................................1
iv
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
Issue 01 (2009-03-30)
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
5/26
GENEX ProbeV100R005C01B050
Release Notes 3 Version Changes
1 Version MappingThis chapter provides the version mapping information about the GENEX Probe
V100R005C01B050. The information involves the versions of the operating system and
software.
1.1 Product Version
Product Name GENEX Probe
Product Model V100R005C01
Product Version V100R005C01B050
1.2 Software Versions
Software Name Software Version
GENEX Assistant V100R005C01B050
1.3 Related Product Versions
None.
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
1
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
6/26
3 Version Changes
GENEX ProbeV100R005C01B050
Release Notes
1.4 Versions of the OS and Database
OS Version DatabaseVersion
Remarks
Microsoft Windows 2000 SP2 and later versions None None
Microsoft Windows XP SP2 and later versions None None
2
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
Issue 01 (2009-03-30)
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
7/26
GENEX ProbeV100R005C01B050
Release Notes 3 Version Changes
2 Version Compatibility
2.1 Compatibility with Earlier Product Versions
This version is compatible with all the earlier commercial versions of the product.
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
1
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
8/26
GENEX ProbeV100R005C01B050
Release Notes 3 Version Changes
3 Version Changes
3.1 Changes from V100R005C01B040 toV100R005C01B050
3.1.1 Feature Changes
New Features
None.
Modified Features
1. [Configuring test plans] Test plans are modified.
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
1
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
9/26
3 Version Changes
GENEX ProbeV100R005C01B050
Release Notes
Description The Attach, Detach, and Ping test plans are modified.
Improvement The number of Detach timeouts is decreased, and the Detach successrate is increased.
The Attach test and Detach test cannot be performed simultaneously.This helps users to perform operations correctly.
The test interval can be set by users. This helps to improve testefficiency.
Implementation
In the configuration of Detach plans, the default value oftime out (sec)is set to 3.
For Attach and Detach test plans, the option Ping Count appearsdimmed. By default, the value ofPing Count is 1 and this value cannot
be changed.
For Ping test plans, the Test interval(ms) drop-down list box is added.
Users can select 100,200, 500, or1000 from this drop-down list box, or
enter another value. By default, 1000 is selected.
RelatedOperation
Set the Attach, Detach, and Ping test plans.
PR Number CMM: P_P_152_001
CMM: P_P_152_002
CMM: P_P_152_003
Feature ID WBFD-010010
2. [Predefining key events] Key events can be predefined.
Description The Record Pause and Record Resume system events are added.
Improvement System events help users to analyze the causes of interruption happenedduring data recording.
Implementation
During the test, if the user chooses Record Pause from the menu, oneRecord Pause system event is generated. If the user chooses RecordResume from the menu, one Record Resume system event is generated.
RelatedOperation
Choose Record Pause orRecord Resume.
PR Number CMM: P_P_152_004
Feature ID WBFD-010030
3. [Setting alarms for special situations] An alarm is generated when a special event occurs.
2
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
Issue 01 (2009-03-30)
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
10/26
GENEX ProbeV100R005C01B050
Release Notes 3 Version Changes
Description An alarm is generated only when a special event occurs on the GSMnetwork.
Improvement In case of any important or exceptional event, an audio alarm is generated.This helps users to find the problem in time.
Implementation
An audio alarm is generated when any of the following events occurs:
GSMCallAttemp
GSMCallSetupFail
GSMCallDropped
GSMCallSetup
Attach
Detach
GPSDisconnected
GSMHandoverFail
GSMHandoverIntracellFail
PDPActivationReq
PDPActivationSuc
PDPActivationFail
Scanner Disconnected
UE Disconnected
RelatedOperation
An audio alarm is generated, indicating an important event or an
exceptional event.
PR Number CMM: P_P_152_005
Feature ID WBFD-010040
4. [Other settings] Some settings related to the hardware configuration and license
management are changed.
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
3
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
11/26
3 Version Changes
GENEX ProbeV100R005C01B050
Release Notes
Description When the UE has an external antenna, the GENEX Probe provides userswith the information about the RxLev, RSCP, and RX Power indicators
related to the external antenna gains.
The license management solution is improved.
Improvement Through the external antenna gain handling, users can obtain accuratetest results after subtracting the external antenna gains from the
indicators.
Through the improved license management solution, users can change
the system time to a value that does not exceed 24 hours.
Implementation
When the UE has an external antenna, the external antenna gains must
be subtracted from the RxLev, RSCP, and RX Power indicators.
The License.dll file is replaced. If the user changes the system time to a
value that exceeds 24 hours, the GENEX Probe only generates a
message to inform users of this change. The dongle, however, stillremains in effect.
RelatedOperation
Set the external antenna gains during the hardware configuration.
When the system time is changed, a message is generated to inform
users of the change.
PR Number CMM: P_P_152_006
CMM: P_P_152_007
Feature ID WBFD-010050
5. [Opening preset windows quickly] The methods of representing some indicators are
changed.
4
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
Issue 01 (2009-03-30)
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
12/26
GENEX ProbeV100R005C01B050
Release Notes 3 Version Changes
Description The Rxlev indicator is represented by an integer. The RxQual indicator isrepresented by discrete values instead of a value segment. The information
about the software version is contained in the drive test data.
Improvement Complying with industry standards, the Rxlev indicator is representedby an integer.
Complying with industry standards, the RxQual indicator is represented
by discrete values. This helps users to understand this indicator.
The version information about the software used for data test is
provided. This helps problem location and user communication.
Implementation
The Rxlev indicator is represented by an integer.
The RxQual indicator is represented by discrete values such as 0, 1, 2,
3, 4, 5, 6, and 7.
The information about the software version is added to the drive testfiles generated during the test.
RelatedOperation
Change the display of the Rxlev indicator on the GUI and the display of
the RxQual indicator on the map. View the file information in the
Information window.
PR Number CMM: P_P_152_008
CMM: P_P_152_009
CMM: P_P_152_010
Feature ID WBFD-030010
6. [WCDMA test] More test devices are supported during WCDMA tests.
Description The U1307, E180, and E176 provided by Huawei are supported duringWCDMA tests.
Improvement More test devices are supported during WCDMA tests.
Implementation
The U1307, E180, and E176 are supported during hardware configuration
and data collection.
RelatedOperation
During hardware configuration, select one of the three types of devicesbased on the actual situation.
PR Number CMM: P_P_152_011
Feature ID WOFD-050010
7. [GSM test] The DTI GSM 850/1900 frequency device is supported during GSM tests.
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
5
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
13/26
3 Version Changes
GENEX ProbeV100R005C01B050
Release Notes
Description DTI GSM 850/1900 MHz tests are supported.
Improvement Users in North America can test the GSM 850/1900 band.
Implementati
onThe DTI GSM 850/1900 scanning data is collected and displayed.
RelatedOperation
During hardware configuration, users can select a device for DTI GSM850/1900 MHz tests. Users can also view the DTI GSM 850/1900
scanning data in the DTI Scanner window.
PR Number CMM: P_P_152_012
Feature ID WOFD-050020
8. [Voice quality assessment] The MIC operation is barred during VQA tests.
Description The MIC operation is barred during VQA tests of mobile originating calls(MOCs).
Improvement The evaluation of the incoming call quality is not affected, and the value ofthe VQA indicator is increased.
Implementation
The GENEX Probe automatically bars the MIC operation before each callsetup.
RelatedOperation
The MIC operation is prohibited automatically during VQA tests.
PR Number CMM: P_P_152_013
Feature ID WOFD-060010
Deleted Features
None.
3.1.2 GUI Changes
None.
6
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
Issue 01 (2009-03-30)
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
14/26
GENEX ProbeV100R005C01B050
Release Notes 3 Version Changes
4 V100R005C01 FeaturesThis chapter introduces the features of V100R005C01B050. For details, see the GENEX Probe
Feature Description.
You can download this document and other related documents from http://support.huawei.com.
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
1
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
15/26
GENEX ProbeV100R005C01B050
Release Notes 3 Version Changes
5 Solved Problems and UnsolvedProblems
5.1 Solved Problems
5.1.1 Improvements of V100R005C01B050 onV100R005C01B040
The RXQUAL_SUB indicator cannot be displayed on the map.
Description
The RXQUAL_SUB indicator cannot be displayed on the map.
Cause The default UE of the GENEX Probe is changed from the U626 to the U120E.The configuration design of the U120E is not comprehensive. This leads to this
problem.
Impact The RXQUAL_SUB indicator cannot be displayed on the map. Therefore,users cannot obtain the information related to the RXQUAL_SUB indicator.
SeverityMajor
Solution Improve the map parameter configuration of the U120E.
PRNumber
CMM: P_P_152_014
Test CaseID
CMM: P_P_152_014
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
1
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
16/26
3 Version Changes
GENEX ProbeV100R005C01B050
Release Notes
The audio alarm raised by a call drop is pronounced "Dataservice drop".
Descripion The audio alarm raised by a call drop is pronounced "Data service drop".
Cause The audio file of the call drop is configured incorrectly.
Impact Incorrect information is provided to users.
SeverityMinor
Solution Modify the configuration of the audio file.
PRNumber
CMM: P_P_152_015
Test Case
ID
CMM: P_P_152_015
The GENEX Probe incorrectly judges the GSMCallSetupFail event.
Descripion The GENEX Probe incorrectly judges the GSMCallSetupFail event.
Cause The GENEX Probe does not switch to the status of GSMCallSetupFail eventbecause it fails to judge the GSMCallSetupFail event correctly.
Impact The GENEX Probe fails to provide the information about the
GSMCallSetupFail event.
SeverityMajor
Solution The rules for judging the GSMCallSetupFail event are modified.
PRNumber
CMM: P_P_152_016
Test CaseID
CMM: P_P_152_016
2
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
Issue 01 (2009-03-30)
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
17/26
GENEX ProbeV100R005C01B050
Release Notes 3 Version Changes
The Anritsu ML 8720B cannot be connected to the GENEX Probe.
Descripion The Anritsu ML 8720B cannot be connected to the GENEX Probe.
Cause The setting of the Stop bitparameter in the GENEX Probe does not meet the
requirements of the Anritsu ML 8720B.
Impact Users cannot use the Anritsu ML 8720B.
SeverityMajor
Solution Change the setting of the Stop bit parameter in the GENEX Probe.
PRNumber
CMM: P_P_152_017
Test CaseID
CMM: P_P_152_017
Time transition occurs in the new file after the data in multiplefiles are merged.
Descripion Time transition occurs in the new file after the data in multiple files aremerged.
Cause The files are not sorted by time. This leads to a time disorder after the datamergence.
Impact Users cannot use the data gained after the mergence.
SeverityMajor
Solution The GENEX Probe sorts the files by time before the data mergence.
PRNumber
CMM: P_P_152_018
Test CaseID
CMM: P_P_152_018
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
3
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
18/26
3 Version Changes
GENEX ProbeV100R005C01B050
Release Notes
For one event, the judgment result provided by the GENEX Probeafter the data mergence is different from that provided by theGENEX Assistant.
Descripion For one event, the judgment result provided by the GENEX Probe after thedata mergence is different from that provided by the GENEX Assistant.
Cause The merged data is not separated by spacing flags. In this case, the status of theevent is not cleared out in time.
Impact Error occurs during event judgment.
SeverityMajor
Solution During data mergence, start identifiers are added to the newly generated file. Inthis case, the data in different files can be separated and the event can be
correctly judged.
PRNumber
CMM: P_P_152_019
Test CaseID
CMM: P_P_152_019
The TOffsetORDelay indicator is named TOffsetORDefaly in theTopN Pilot window.
Descripion The TOffsetORDelay indicator is named TOffsetORDefaly in the TopN Pilotwindow.
Cause The spelling of the indicator name is incorrect.
Impact Users cannot understand this indicator.
SeverityMinor
Solution Correct the spelling of this word.
PR
Number
CMM: P_P_152_020
Test CaseID
CMM: P_P_152_020
4
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
Issue 01 (2009-03-30)
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
19/26
GENEX ProbeV100R005C01B050
Release Notes 3 Version Changes
No information about the WCDMA sites is displayed in the CELLwindow after the user selects one or multiple sites from themap.
Descripion The WCDMA engineering parameters are displayed on the map, but noinformation about the WCDMA sites selected by users is displayed in theCELL window.
Cause The information about the WCDMA sites is not handled in the CELL window.
Impact Users cannot obtain the cell information in time.
SeverityMinor
Solution Add the information about the WCDMA sites in the CELL window andsynchronize the information with the selected sites.
PRNumber
CMM: P_P_152_021
Test CaseID
CMM: P_P_152_021
The information about the three sectors of the same site isoverlapped when the information is displayed on the map.
Descripion Engineering parameters can be displayed on the map. After the user selects oneparameter, the information about the three sectors of one site is overlapped
when the information is displayed on the map.
Cause Display offset is not considered when the cell information is displayed.
Impact Users cannot identify the information about different cells.
SeverityMajor
Solution When the cell information is displayed on the map, offsets are considered onthe basis of the sector direction.
PRNumber
CMM: P_P_152_022
Test CaseID
CMM: P_P_152_022
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
5
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
20/26
3 Version Changes
GENEX ProbeV100R005C01B050
Release Notes
The C/I indicator is named CI on the DTI GSM map.
Descripion The C/I indicator is named CI on the DTI GSM map.
Cause The spelling of the indicator name is incorrect.
Impact Users regard that this indicator refers to the ID of a cell, that is, cell ID.
SeverityMinor
Solution Correct the spelling of this word.
PRNumber
CMM: P_P_152_023
Test CaseID
CMM: P_P_152_023
No LAC data is displayed in the UE STATE window during WCDMAtests.
Descripion No LAC data is displayed in the UE STATE window during WCDMA tests.
Cause The LAC data of the WCDMA network is not parsed.
Impact Users cannot obtain the LAC data.
SeverityMajor
Solution Enable the function of parsing the LAC data of the WCDMA network in theUE STATE window.
PRNumber
CMM: P_P_152_024
Test CaseID
CMM: P_P_152_024
6
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
Issue 01 (2009-03-30)
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
21/26
GENEX ProbeV100R005C01B050
Release Notes 3 Version Changes
If the user imports the engineering parameters whose TCHhopping SNs are separated by comma, and then saves theparameters, the TCHs are displayed in different lines.
Descripion If the user imports the engineering parameters whose TCH hopping SNs areseparated by comma, and then saves the parameters, the TCHs are displayed indifferent lines.
Cause Commas are specified to separate the lines in a .csv file. If commas exist inengineering parameters, the parameters are separated after being saved to a
.csv file.
Impact All the TCHs whose TCH hopping SNs are separated by comma cannot besaved.
SeverityMinor
Solution When saving engineering parameters to a .csv file, change all commas existingin the parameters to semicolons.
PRNumber
CMM: P_P_152_025
Test CaseID
CMM: P_P_152_025
On the map, the line indicating the relation between the dataand its corresponding serving cell does not point to the edge ofthe cell.
Descripion On the map, the line indicating the relation between the data and itscorresponding serving cell does not point to the edge of the cell.
Cause The latitude and longitude are inaccurate.
Impact Users cannot know the serving cell corresponding to the data.
SeverityMinor
Solution Improve the latitude and longitude precision.
PRNumber
CMM: P_P_152_026
Test CaseID
CMM: P_P_152_026
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
7
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
22/26
3 Version Changes
GENEX ProbeV100R005C01B050
Release Notes
If a file contains the drive test data of both the TSML and the120E, the GENEX Probe cannot export only the TSML data.
Descripion If a file contains the drive test data of both the TSML and the 120E, theGENEX Probe cannot export only the TSML data. That is, no TSML data is
contained in the newly generated file.
Cause The TSML data is not handled during the data export.
Impact Users cannot detach the TSML data from other data.
SeverityMajor
Solution Handle the TSML data during the data export.
PRNumber
CMM: P_P_152_027
Test CaseID
CMM: P_P_152_027
5.2 Unsolved Problems
None.
8
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
Issue 01 (2009-03-30)
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
23/26
GENEX ProbeV100R005C01B050
Release Notes 3 Version Changes
6 PrecautionsAfter the devices such as the DTI, TSML-W, Anritsu scanner, and GPS are used for one year,
Huawei engineers need to check the precisions of the devices with device providers to ensure
the normal operation of these devices.
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
1
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
24/26
GENEX ProbeV100R005C01B050
Release Notes 3 Version Changes
7 Related DocumentsThe documents for this release are delivered with the software package. Huawei engineers can
obtain these documents when downloading the software package and need to deliver these
documents to the customer.
If the documents for a software patch (SP) version are not delivered with the software package, the
documents for the build (B) version corresponding to the patch version can be used. Huawei engineers canobtain the related documents from the directory of the corresponding build version.
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
1
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
25/26
GENEX Probe V100R005C01B050
Release Notes A Acronyms and Abbreviations
Figure 1.1Acronyms andAbbreviations
Numerics
C
C/I Carrier-to-Interference ratio
G
GPS Global Position System
L
LAC Location Area Code
M
MIC Microphone
R
RSCP Received Signal Code Power
T
TCH Traffic Channel
U
UE User Equipment
V
VQA Voice Quality Assessment
Issue 01 (2009-03-30)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co.,
Ltd
1
-
7/31/2019 GENEX Probe V100R005C01B050 Release Notes
26/26
A Acronyms and Abbreviations
GENEX ProbeV100R005C01B050
Release Notes
Huawei Proprietary and Confidential