1. The structural notes are intended to complement the project specifications. Specific notes and details in thedrawings shall govern over the structural notes and typical details.
2. Typical details and sections shall apply where specific details are not shown.3. The contractor shall verify all site conditions and dimensions. If actual conditions differ from those shown in the
contract drawings, the contractor shall immediately notify the architect/engineer before proceeding with thefabrication or construction of any affected elements.
4. Drawings shall not be scaled for the purpose of preparing shop drawings or for construction. Where dimensionson the design drawings are not provided or inferred, the contractor may scale drawings only to estimate memberlengths for the purpose of bidding.
5. Changes to these contract drawings may be made only by an authorized representative of Dunn Associates, Inc.Dunn Associates, Inc. shall not be held responsible or liable for any claims arising directly or indirectly fromchanges made without written authorization by an authorized representative of Dunn Associates, Inc.
6. Omissions or conflicts between the contract drawings and/or specifications shall be brought to the attention of thearchitect/engineer before proceeding with any work involved. In case of conflict, follow the most stringentrequirement as directed by the architect/engineer at no additional cost to the owner.
7. The contractor shall submit a written request to the architect/engineer before proceeding with any changes,substitutions, or modifications. Any work done by the contractor before receiving written approval will be at thecontractor's risk.
8. The contractor shall coordinate with all trades any items that are to be integrated into the structural system suchas openings, penetrations, mechanical and electrical equipment, etc. Sizes and locations of mechanical andother equipment that differs from those shown on the contract drawings shall be reported to thearchitect/engineer. Contractor shall take measures as required to insure that construction loads shall not exceeddesign loads for the structure.
9. The contractor shall be responsible for means, methods, techniques, sequences, and procedures in order tocomply with the contract drawings and specifications. The contractor shall provide adequate shoring and bracingas required for the chosen method of erection. Shoring and bracing shall remain in place until final connectionsfor the permanent members are completed. The building shall not be considered stable until all connections arecompleted. Walls shall not be considered self-supporting and shall be braced until the floor/roof system iscompleted.
10. Site observations by a field representative of Dunn Associates, Inc. shall not be construed as approval ofconstruction, the procedures, nor special inspection.
12. All work shall be done in accordance with OSHA requirements. Potential conflicts between these documents andOSHA requirements shall be brought to the attention of the structural engineer before proceeding with the work.
13. Shop Drawings and submittals:13.1. Review of shop drawings and submittals by Dunn Associates, Inc. is for general compliance only and is
not intended for approval. The shop drawing review shall not relieve the contractor from the responsibilityof completing the project according to the contract documents.
13.2. Submittals for the following items shall be submitted to the Project Architect/Engineer for review prior tofabrication and/or installation:13.2.1. Concrete Mix Design13.2.2. Concrete Reinforcing13.2.3. Masonry Block and Grout13.2.4. Masonry Reinforcing13.2.5. Anchorage and Embeds13.2.6. Structural Steel13.2.7. Steel Open Web Joists13.2.8. Steel Decking13.2.9. Deferred Design Items
13.3. Quality control submittals shall be submitted to special inspector for review prior to fabrication/installation.Courtesy copies shall be provided to the project architect and engineer for their records.
13.4. Detailing and shop drawing production for structural elements will require information (includingdimensions) contained in the architectural, structural and/or other consultants' drawings. The structuraldrawings shall be used in conjunction with the architectural and other consultant's drawings. See theArchitectural Drawings for dimensions, doors, windows, non-bearing interior and exterior walls, elevations,slopes, stairs, curbs, drains, recesses, depressions, railings, waterproofing, finishes, chamfers, kerfs, etc.
13.5. Shop drawings made from reproductions of the structural drawings will be rejected unless the contractorsigns a release agreement prior to the shop drawings being reviewed. The contractor may also obtainelectronic files of the plan sheets after signing a release agreement. Electronic files of the detail sheetsand schedule sheets will not be made available.
13.6. The Contractor may choose to submit shop drawings and submittals for review electronically. TheContractor may do this provided a minimum of one hard copy set is submitted for review. The submittalwill be stamped as received by Dunn Associates, Inc. when the hard copy is received by our office. Hardcopies of small submittals need not be submitted if the Contractor receives the approval for this exceptionby the Engineer of Record.
BASIS OF DESIGN
1. Governing Building Code---------------------------------------------- International Building Code 20152. Risk Category------------------------------------------------------------- III3. Floor Live Loads
3.1. Uniformly Distributed Loads3.1.1. Offices + Partitions-----------------------------80 psf3.1.2. Lobbies & Main Floor Corridors------------ 100 psf3.1.3. Catwalks/Fly Gallery-------------------------- 60 psf3.1.4. Light Storage------------------------------------125 psf3.1.5. Stage Floor/Mechanical Rooms----------- 150 psf
3.2. Concentrated Loads, all areas------------------------------ 2000 lbs4. Roof Snow Load
4.1. Ground Snow Load-------------------------------------------- Pg = 43 psf4.2. Flat Roof Snow Load------------------------------------------ Pf = 40 psf4.3. Snow Exposure Factor--------------------------------------- Ce = 1.04.4. Thermal Factor------------------------------------------------- Ct = 1.24.5. Snow Load Importance Factor------------------------------ Is = 1.1
5. Wind Load5.1. Ultimate Wind Design Speed -------------------------------120 mph5.2. Wind Exposure------------------------------------------------- B5.3. Internal Pressure Coefficient-------------------------------- ± 0.18
6. Seismic Design Criteria6.1. Mapped Spectral Response Accelerations
6.1.1. Short Period Acceleration------------------- SS = 1.5426.1.2. 1-Second Acceleration----------------------- S1 = 0.530
6.2. Spectral Response Coefficients6.2.1. Short Period Acceleration------------------- SDS = 1.0286.2.2. 1-Second Acceleration----------------------- SD1 = 0.530
6.2. Site Class (Soil Profile)--------------------------------------- D6.3. Seismic Importance Factor---------------------------------- 1.256.4. Seismic Design Category------------------------------------ D6.5. Effective Structural Seismic Weight----------------------- W
6.5.1. Lateral Force Resisting System------------Special Masonry Shear Walls/Ordinary Steel MF6.5.2. Response Modification Coefficient-------- R = 5/3.56.5.3. System Overstrength Factor---------------- Ωo = 2.5/36.5.4. Deflection Amplification Factor------------- CD = 3.5/36.5.5. Design Base Shear---------------------------- V = Cs*W = 0.257W, 0.367W
6.6. Analysis Procedure-------------------------------------------- Equivalent Lateral Force7. Serviceability Criteria
7.1. Interstory Seismic/Wind Drift-------------------------------- Δa < 0.015h ('h' is story height)7.2. Deflection Limits------------------------------------------------ Total----------------- Live/Snow/Wind
Floor--------------------------------------------------------------- L/240---------------- L/360Roof---------------------------------------------------------------- L/240---------------- L/360Perimeter--------------------------------------------------------- ____----------------- L/600(3/8" max)Wall---------------------------------------------------------------- ____----------------- L/240
FOUNDATION
1. Soils Report by:---------------------------------------------------------- Gordon Geotechnical Engineering, Inc.2. Report Number & Date:------------------------------------------------ August 2, 20163. Soil Bearing Pressure:--------------------------------------------------1,500 psf, on Suitable Native Soils4. Frost Protection:----------------------------------------------------------30 inches minimum5. Lateral Soil Pressure Fluid Equivalent Density:
5.1. Active------------------------------------------------------------- 45 pcf (retaining walls)5.2. Lateral Seismic Soil Pressure-------------------------------100 psf5.3. Passive----------------------------------------------------------- 300 pcf
6. Coefficient of Friction--------------------------------------------------- 0.5
EARTHWORK
1. Consult the project specifications and soils report for further earthwork requirements. In absence of information,refer to the following notes.
2. Clearing: The entire building area shall be scraped to remove the top 4" of soil including all vegetation and debris.3. Contractor shall provide temporary shoring for excavations as required.4. Contractor shall provide measures necessary to prevent damage to or settlement of new or existing construction
and utilities on or adjacent to project site.5. Contractor shall provide dewatering as required to protect the site from flooding.6. Proof rolling: The natural undisturbed soil below all footings shall be proof rolled prior to placing concrete.
Remove all soft spots and replace with compacted structural fill.7. Compacted structural fill: All fill material shall be a well-graded granular material with a maximum size less than 4"
and with not more than 10% passing a #200 sieve. Fill beneath footings shall be compacted to 95% of themaximum laboratory density as determined by ASTM D 1557. All fill shall be tested. Compacted structural fillshall be placed in lifts not exceeding 8" in uncompacted thickness.
8. Floor slabs shall be underlain by a granular layer at least 4" thick. The granular layer shall have a maximum sizeless than 1" with not more than 5% passing a #200 sieve and shall be compacted to at least 90% of the maximumlaboratory density as determined by ASTM D 1557.
9. The soils engineer shall review all excavations and fill placement prior to placing concrete.
Table Footnotes:a. Cement to comply with ASTM C150. Use Type V cement where required by soils report.b. Air content ± 1.5%, measured at point of final placement. Air-entraining admixtures shall comply with
ASTM C260 (when used). Calcium chloride shall not be added to the concrete mix. Unreinforced concreteslabs on grade may have calcium chloride not exceeding one percent.
c. Air entrainment shall be adjusted for the use of admixtures and fly ash.d. Slump limit ± 1" applies to non-plasticized concrete. Test shall be conducted prior to adding
plasticizer if used.e. These values shall be used for parking slabs on grade or other slabs within the building footprint
with exterior exposure. See civil drawings for site concrete requirements.1. Materials unless noted otherwise:
1.1. Normal Weight aggregates----------------------------------------------------------- ASTM C331.2. Fly Ash, Class F Pozzolan----------------------------------------------------------- ASTM C6181.3. Reinforcing Steel
1.3.1. General------------------------------------------------------------------- ASTM A615 Grade 601.3.2. Columns, Beams, Shearwalls--------------------------------------- ASTM A706-60ksi
ASTM A615 is permitted if mill certifications are submitted showing that actual yield strengthdoes not exceed the specified strength by more than 18000 psi, the ratio of tensile to yieldstrength is greater than 1.25, and required minimum elongations of A706 are met.
1.3.3. Subject to the above requirements, ASTM A615 Grade 75 steel may be used at thecontractor's option, except in special moment frames, special concrete shear walls, shearstirrups or torsional reinforcement.
1.4. Deformed Bar Anchors (DBA) ------------------------------------------------------ ASTM A4961.5. Headed Stud Anchors (HSA) ------------------------------------------------------- ASTM A1081.6. Anchor Bolts: See steel and/or wood section(s) of general notes.1.7. No aluminum conduit or product containing aluminum or any other material injurious to concrete shall be
embedded in concrete.2. The contractor shall be responsible for the design, detailing, care, placement and removal of all formwork and
shores.2.1. Supporting forms and shoring shall not be removed until structural members have acquired sufficient
strength to safely support their own weight and any construction load to which they may be subjected. Inno case, however, shall forms and shoring be removed in less than 24 hours after concrete placement.
3. Reinforcement shall have the following concrete clear cover:3.1. Cast-in-place Concrete
3.1.1. Cast against and permanently exposed to earth--------------- 3"3.1.2. Formed concrete exposed to earth or weather:
#6 thru #18 bars-------------------------------------------------------- 2"#5 and smaller bars--------------------------------------------------- 1 1/2"
3.1.3. Concrete not exposed to weather or in contact with ground:Slabs, Walls, Joists; #11 bars and smaller --------------------- 3/4"Beams, Columns: Primary Reinforcement, Ties,-------------- 1 1/2"Stirrups, Spirals
4. Construction Joints and Control Joints:4.1. Provide a beveled 2" x 4" x continuous or intermittent keyway in all horizontal and vertical construction
joints including between top of footing and foundation walls. In addition, all joints shall be intentionallyroughened to a full amplitude of approximately 1/4".
4.2. Control joints shall be installed in slabs on grade so the length to width ratio of the slab is no more than1.25:1. Control joints shall be completed within 12 hours of concrete placement. Control joints may beinstalled by either:4.2.1. Saw cut with depth of 1/4 the thickness of the slab4.2.2. Tooled joints with depth of 1/4 the thickness of the slab
4.3. Install construction or control joints in slabs on grade at a spacing not to exceed 30 times the slabthickness in any direction, unless noted otherwise. Construction joints shall not exceed a distance of125'-0" on center in any direction.
5. Construction5.1. Use chairs or other support devices recommended by the CRSI to support bar and tie reinforcement bars
and WWR prior to placing concrete. WWR shall be continuously supported at 36" on center maximum.Reinforcing steel for slabs on grade shall be adequately supported on precast concrete units. Lifting thereinforcing off the grade during placement of concrete is not permitted.
5.2. Contractor shall coordinate placement of all openings, curbs, dowels, sleeves, conduits, bolts, inserts andother embedded items prior to concrete placement.
5.3. All embeds and dowels shall be securely tied to formwork or to adjacent rebar prior to concrete placement.5.4. No pipes, ducts, sleeves, etc. shall be placed in structural concrete unless specifically detailed or
approved by the structural engineer. Penetrations through walls when approved shall be built into the wallprior to concrete placement. Penetrations will not be allowed in footings or grade beams unless detailed.Piping shall be routed around these elements and footings stepped to avoid piping.
5.5. Reinforcing bars shall not be welded unless specifically shown on drawings. In such cases, use only AWSstandards. Do not substitute reinforcing bars for DBAs or HSAs.
5.6. Reinforcing bars partially embedded in concrete shall not be field bent, except as shown in the contractdrawings or permitted by the EOR.
5.7. Top of concrete columns shall be flush (±1/4") with bottom of supported cast-in-place members.6. Detailing:
6.1. Lap splice lengths shall be detailed to comply with the "Reinforcing Bar Lap Splice Schedule" containedwithin the contract drawings.6.1.1. Do not splice stirrups and ties. Do not splice vertical bars in retaining walls unless specifically
shown.6.1.2. At shear wall boundary elements lap lengths shall be increased by 25%.6.1.3. Splices may be made with mechanical splices capable of 125% of yield strength of the bar
being spliced (Type 1). Splices located within lateral resisting elements shall also develop thetensile strength of the bar (Type 2). Mechanical splices shall be the positive connecting typecoupler and shall meet all ACI requirements. Use "Cadweld", "Lenton" Standard Couplers,"Bar-Lock" or equal with internal protector. If mechanical splices are used, splices or couplerson adjacent bars shall be staggered a minimum of 24" apart along the longitudinal axis of thereinforcing bars.
6.2. At joints provide reinforcing dowels to match the member reinforcing, unless noted otherwise.6.3. At all discontinuous control or construction slab on grade joints, provide (2) #4 x 48".6.4. Provide corner bars at intersecting wall corners using the same bar size and spacing as the horizontal wall
reinforcing.6.5. All vertical reinforcing shall be doweled to footings, or to the structure below with the same size and
spacing as the vertical reinforcing for the element above. Dowels extending into footings shall terminatewith a 90° standard hook and shall extend to within 4" of the bottom of the footing. Footing dowels (#8bars and smaller) with hooks need not extend more than 20" into footings.
6.6. In concrete shearwalls, the horizontal wall reinforcing shall terminate at ends of walls and openings intothe far end of the jamb column with a standard hook . Horizontal wall reinforcing shall be continuousthrough construction and control joints. Ties on boundary elements shall extend a minimum of 12" into thefoundation.
6.7. See details for reinforcing around miscellaneous openings. All recesses that interrupt reinforcing shall bereinforced the same as an opening.
6.8. Reference ACI 315 for additional detailing requirements.7. Contractor required to submit concrete mix design for review by the engineer prior to any placement of concrete.8. Contractor shall refer to and follow the recommendations in ACI 305R for hot weather concreting and ACI 306R
for cold weather concreting.9. Contractor is not to backfill against retaining walls unless walls have achieved design strength or have been
shored. Contractor is not to backfill against basement walls without placement of the main floor diaphragm unlessthe walls have been shored or approval of the EOR has been granted, or it has been noted otherwise on thedesign drawings.
10. Construction activity or storage of materials shall not take place on newly placed concrete for a minimum of 7days after concrete placement.
Concrete Use Comp. Strengthf 'c (psi)
ExposureClasses
CementType
Max. W/CMRatio
Max.Flyash
AirContent
AggregateSize, Max.
SlumpLimit
Interior Slabs on Grade 3500 F0, S0, P0, C0 I, II 0.45 25% 1.5% 3/4" 5"
Exterior Concrete(reinforced)
5000 F3, S0, P0, C2 I, II 0.40 25% 6% 3/4" 4"
ab,c
d
CONCRETE
Concrete shall be supplied in accordance with ACI 318 and the following requirements:
Exterior Concrete(unreinforced)
4500 F3, S0, P0, C0 I, II 0.45 25% 6% 3/4" 4"
e
e
Footings 4500 F1, S0, P0, C0 I, II 0.45 25% 4.5% 1 1/2" 5"
Mat Footings 4500 F1, S0, P0, C0 I, II 0.45 25% 4.5% 1 1/2" 5"
Foundation Walls 4500 F1, S0, P0, C1 I, II 0.45 25% 5% 3/4" 4"
POST-INSTALLED ANCHORS
1. Post-installed anchors shall only be used where specifically detailed or called for on the design drawings. Ifcircumstances arise during construction where the Contractor desires to substitute a post-installed anchor inplace of a cast-in-place anchor, the Contractor shall submit a formal written request for each circumstance to theArchitect and Engineer for review.
2. Follow all ICC Evaluation Report and manufacturers' requirements and recommendations for post-installedanchor installation. Where conflicts may exist, the most stringent requirement applies.
3. Post-installed anchors that are exposed to exterior conditions, or interior spaces where moisture can accumulate,shall be either galvanized or stainless steel anchors.
4. For installation of adhesive anchors horizontally or vertically inclined, installers must have AMI/CRSI AdhesiveAnchor Installer Certification.
5. Follow manufacturer and ICC evaluation report requirements for installation temperature of adhesive anchors.Adhesive anchors shall not be installed or cured outside of approved temperature ranges. Adhesive anchors maynot be installed in concrete less than 21 days old without prior approval.5.1. Adhesive anchors in concrete (normal weight only) shall be
5.1.1. HIT-RE 500-SD by Hilti (ESR-2322)5.1.2. HIT-RE 500v3 by Hilti (ESR-3814)5.1.3. HIT-HY 200 by Hilti (ESR-3187)5.1.4. SET-XP by Simpson (ESR-2508)5.1.5. AT-XP by Simpson (IAPMO ES ER-0263)5.1.6. Pure 110+ by Powers (ESR-3298)5.1.7. Epcon S7 by ITW (ESR-2308)5.1.8. Epcon G5 by ITW (ESR-1137)5.1.9. Epcon C6+ by ITW (ESR-3577)
MASONRY
1. Materials, unless noted otherwise:1.1. Concrete Masonry Units (CMU): Medium weight (115pcf) (min. unit strength of 1900 psi) f'm = 1900 psi1.2. Mortar: Type "S" (1800 psi minimum compressive strength)1.3. Grout shall attain a minimum compressive strength of 2000 psi at 28 days.1.4. Reinforcing Steel----------------------------------------------- ASTM 615 Grade 60 (Fy = 60 ksi)1.5. Deformed Bar Anchors (DBA)------------------------------ ASTM A4961.6. Headed Stud Anchors (HSA)------------------------------- ASTM A1081.7. Anchor Bolts----------------------------------------------------- ASTM A3071.8. Heavy hex nuts and hardened washers------------------ ASTM A563
2. Reinforcement shall have the following cover:2.1. Other reinforcement shall have a minimum coverage of one bar diameter over all the bars, but not less
than 3/4". When masonry is exposed to soil, minimum coverage shall be 1 1/2".3. Construction Requirements
3.1. All units shall be laid with full mortar beds on the face shells. All head joints shall be filled solidly withmortar for a distance in from the face of the units not less than the thickness of the longitudinal face shells. Cells which are to be grouted shall have full head joints.
3.2. Masonry walls, beams and columns shall be constructed with running bond unless noted otherwise.3.3. Solid grouting of walls is unacceptable except where specifically noted.3.4. All cells containing reinforcement, embeds, anchor bolts, etc. shall be filled solid with grout. Grout shall be
placed by mechanical vibration during placing and revibrated after excess moisture has been absorbedbut before workability is lost. Puddling or rodding of grout is not allowed.
3.5. Where walls are not grouted solid, each grout pour shall terminate flush with the top of the uppermost unitexcept at cells with vertical reinforcing where the grout shall be 1 1/2" below top of unit to provideconstruction key.
3.6. Grout pours shall be limited to 5'-0" unless high lift grouting procedures are followed.3.7. All masonry below grade shall be solid grouted and use Type "M" mortar (2500 psi minimum compressive
strength).3.8. Vertical cells to be filled with grout shall have vertical alignment sufficient to maintain a clear,
unobstructed, vertical cell measuring not less than 2" by 3". All steel reinforcement shall be securedagainst displacement prior to grouting by wire positioners or other suitable devices at intervals notexceeding 200 bar diameters or 10'-0" maximum, or at bar splice locations. Vertical reinforcing shall belocated at the center of the wall unless noted otherwise.
3.9. Reinforcing bars shall not be welded unless specifically shown on drawings. In such cases, use only AWSstandards. Do not substitute reinforcing bars for DBAs or HSAs.
3.10. Control Joints: Spacing shall not exceed 26'-0". See architectural drawings for locations.3.11. Grout all beam and joist pockets solid after installation of beams and joists.3.12. Embed channels and plates shall be placed so as to create a flush surface with the face of the wall.3.13. Anchor bolts and headed stud anchors shall be set in a grouted cell. Anchor bolts and headed stud
anchors shall have 1/2" grout surrounding the shank at its penetration. Grout shall be flush with the face ortop of the masonry.
4. Detailing Requirements4.1. Lap all masonry reinforcing per the "Masonry Reinforcing Bar Lap Splice Schedule" contained within the
contract drawings. In the absence of this schedule, lap all masonry reinforcing per bar size as follows:4.1.1. Single bars centered in each cell: #3 = 16", #4 = 22", #5 = 26",#6 = 43", #7 = 60", #8 = 72", #9
= 82"4.1.2. Flush wall pilaster/column, 2 bars per cell with 2.5" cover: #3 = 16", #4 = 22", #5 = 32", #6 =
54", #7 = 63", #8 = 72", #9 = 82"4.2. All vertical reinforcing shall be doweled to the foundation wall, footing (structure below) and to the
structure below with the same size dowel, spacing (and in the same core) as the vertical wall reinforcingabove.
4.3. Corner Bars: Horizontal reinforcement shall be continuous at all corners and at intersecting walls.Provide corner bars with the required lap splice length.
4.4. See details for reinforcing around miscellaneous openings.4.5. Horizontal wall reinforcing shall be continuous through joining concrete walls, masonry walls, columns,
and pilasters. Provide a key between the wall and the column or pilaster. Horizontal wall reinforcing shallbe placed inside the column vertical reinforcing.
4.6. Horizontal reinforcing shall terminate with a standard hook at edge of openings and ends of walls withoutcorner bars as shown in details.
4.7. Horizontal wall reinforcing shall terminate with a standard 180° hook at each side of control joints exceptat floor and roof levels, lintels, beams and at top of parapets as shown in details.
4.8. All masonry column ties shall terminate with 135° hooks plus a 6 bar diameter extension (4" minimum).
STRUCTURAL STEEL
1. Codes and Standards: Fabrication, Erection and Quality Control of structural steel shall comply with the latestedition of the following:1.1. American Institute of Steel Construction (AISC) 360, "Specification for Structural Steel Buildings," with
"Commentary".1.2. AISC 341 "Seismic Provisions for Structural Steel Buildings."1.3. AISC 303 "Code of Standard Practice" excluding sections 3.4, 4.4 and 4.4.1.1.4. AISC "Specification for Structural Joints Using ASTM A325 or A490 Bolts"1.5. American Welding Society (AWS), Structural Welding Codes D1.1, D1.3, D1.4, and D1.8, except as
modified by the "Steel Construction Manual".2. Material:
2.1. Wide Flange Sections---------------------------------------- ASTM A992 (50 ksi)2.2. Plate
2.2.1. Typical------------------------------------------- ASTM A362.2.2. Braced/Moment Frames--------------------- ASTM A572 Grade 50
2.3. Notch-toughness requirements apply for demand critical welds. Minimum Charpy V-Notch requirementsare 20 ft-lbs at 0°F and 40 ft-lbs at 70°F
2.4. Hollow Structural Shapes2.4.1. Rectangular------------------------------------- ASTM A500 Grade B (46 ksi)2.4.2. Round-------------------------------------------- ASTM A500 Grade B (42 ksi)
2.5. Other Structural Shapes (M, C, etc)----------------------- ASTM A362.6. Bolted Connections-------------------------------------------- ASTM A3252.7. Anchor Bolts
2.7.1. All Columns unless noted otherwise: ASTM F1554 Grade 105 with ASTM A563 heavy hexnuts with Grade A hardened washers.
2.7.2. Braced Frame/Moment Frame Columns unless noted otherwise: ASTM F1554 Grade 105(equiv to A193 Grade B7) with ASTM A563 heavy hex nuts with ASTM F436 minimum 5/16"thick washers. Bottom assembly to include double heavy hex nuts with 5/16" min thick platewasher.
2.8. Weld Filler Metal2.8.1. Shielded Metal Arc Welding---------------- AWS A5.1, low-hydrogen only
Low-hydrogen restrictions do not apply when welding sheet steels in accordance with AWSD1.3, including attaching these steels to structural members.
2.8.2. Gas-Metal & Metal-Cored Arc Welding-- AWS A5.182.8.3. Flux-Cored Arc Welding--------------------- AWS A5.20
E7XT-4 or E7XT-11 electrodes are not permitted.2.8.4. Intermixing of welds made from self-shielded welding electrodes with welds made by other
processes is not allowed in seismic critical welds, unless tested in accordance with AWSD1.8, annex B. The Field Erection Contractor is responsible for verifying that intermixing ofself-shielded weld metal with weld metal of other processes will not occur, or alternatively, thewelding procedure is qualified by testing.
2.9. Deformed Bar Anchors (DBA)------------------------------ ASTM A4962.10. Headed Stud Anchors (HSA)------------------------------- ASTM A1082.11. Non-Shrink Grout---------------------------------------------- ASTM C1107 Grade B
Non-shrink grout shall be prepackaged, non-metallic and non-gaseous.Furnish certified independent test data to Structural Engineer.Fluid Consistency (flow cone) = 20 to 30 secondsCompressive Strength in 28 days = 7,500 psi
2.12. Refer to architectural drawings for structural steel fireproofing requirements .3. Structural Detailing
3.1. Welds may be performed in the shop or the field. Designations of field welds on the Contract Documentsare shown where it is anticipated field welds may be required, and are shown only for the purpose ofassisting the Contractor in the bidding process. The Contractor shall coordinate the welding sequencebetween sub-contractors, and any costs associated with variations in the welding sequence are outsidethe scope of the Design Engineer, and are the responsibility of the Contractor. Field welding is to beminimized where possible. Contractor is to verify that the sequencing of welds meets all safetyregulations, and the requirements of the Construction Documents and their referenced codes.
OPEN WEB STEEL JOISTS AND GIRDERS
1. All open web steel joist and girders shall be fabricated and erected in accordance with the latest edition of SteelJoist Institute (SJI), "Standard Specifications and Code of Standard Practice."
2. Joists or girders with slopes greater than 1/2" per foot shall be designed to meet or exceed the load capacities,listed in the SJI load tables, of the joist or girder sizes indicated on the framing plan, as if the joists or girders wereinstalled level.
3. Provide special bearing ends to accommodate slopes from sloped joists, sloped girders or sloped bearingconditions.
4. Modifications to any joist or girder, including holes through the top and bottom chords, without the written consentand direction from the manufacturer is not allowed.
5. Design loads, unless noted otherwise:5.1. Wind loads (W) shown are calculated using ASCE 7.5.2. Seismic loads (E and Em) shown are calculated using ASCE 7.5.3. Gravity loads (D, L, S, etc.) shown are Allowable Stress (Working Stress) levels.5.4. Loads shown are at levels to be used directly by the Load Combinations from Section 1605 of the IBC
without further adjustment.5.5. Allowable stress increases are permitted as allowed by the referenced standard being used for design.
6. The deflection of all open web joists and girders shall be limited to L/240 for total load and L/360 for live load,unless noted otherwise.
7. A certificate of compliance must be submitted to the building official upon completion of fabrication per IBC 2207.5.
METAL DECKING
1. Steel deck shall comply with the latest requirements of the Steel Deck Institute.2. Steel deck material shall comply with the manufacturer's ICC Report and have a minimum yield strength of 33ksi.3. All deck shall be 3-span continuous minimum. In areas where 3-span conditions are not possible, the contractor
shall provide heavier gauge deck as required to provide the equivalent loading of the specified deck under a3-span condition.
4. Steel roof deck shall not be used to support loads from plumbing, fire sprinklers, HVAC ducts, light fixtures,architectural elements, or equipment of any kind, unless specifically noted.
5. Conduits are permitted in deck slabs subject to local code requirements and fire rating considerations. Whenconduit is installed in the slab, it shall be limited to conduits of 1" diameter or less, or less than 1/3 the concretecover over flutes, and no crossovers occur, and conduit is spaced at least 18" apart with a 3/4" minimum cover.
6. All members supporting deck shall be dry before welding.7. Crimp seams before button punching or welding interlocking seams.8. Where deck is to receive sprayed-on fire proofing, painted deck shall be coated with special paint that will allow
the sprayed-on fire proofing to adhere to the painted deck.9. All welds performed on roof deck or galvanized deck are to be painted.10. Steel deck shall be galvanized (G60) when used above or below mechanical equipment rooms.11. Steel roof deck shall be painted with interlocking side seams with the following minimum properties:
Type/Ga-------------S(in3/ft)-----------------I (in4/ft)-------------Allowable shear value---------------Notes1 1/2" B/20----------0.233--------------------0.223----------------1170 plf for 7'-0" span---------------Type 13" N/18--------------0.663---------------------1.369----------------1057 plf for 12'-0" span-------------Type 211.1. Weld steel roof deck to supporting framing members with 3/4" diameter puddle welds at the following
spacings (Closer spacings may be used to develop minimum shear requirements):11.1.1. 6" on center to all supports perpendicular to deck corrugations (7 welds per 36" sheet) or 8"
on center for Type N deck (4 welds per 24" sheet).11.1.2. 6" on center to all supports parallel to deck corrugations.11.1.3. Interlocking side seams between adjacent pieces of decking may be attached with "PunchLok
II" by Verco Manufacturing (VSC2) or "ASC DeltaGrip side seam connection" by ASC SteelDeck at 12" on center minimum.
11.2. The Contractor may submit, for review and approval, the manufacturer's ICC report of an alternate methodof deck attachment, including Hilti X-HSN 24 (open web joist attachment) and Hilti X-ENP 19 (steel beamattachment). The alternate method shall provide minimum deck diaphragm shear values equal to orgreater than those noted above. The alternate method shall be approved by the engineer of record priorto the substitution.
11.3. Provide a minimum deck bearing of 2". Lap splices shall be centered over the support. To ensure properlap placement, 4" of lap is recommended, however, it may be reduced to 2" minimum. Deck laps less thanthe minimum will need to be replaced with deck that meets the minimum lap.
COLD FORMED STEEL
1. Cold Formed Steel Framing1.1. The design of cold formed steel and low alloy steel structural members shall be in accordance with
AISI-NASPEC, North American Specification for the Design of Cold-Formed Steel Structural Members.1.2. The design, installation and construction of cold formed steel for structural and non-structural framing shall
be in accordance with AISI-CFSD, Standard for Cold-Formed Steel Framing - General Provisions.1.3. All steel framing members shall comply with ASTM A1003.1.4. Follow all manufacturers' guidelines and recommendations for all products.1.5. Unless noted otherwise, all welded connections shall be done according to AWS standards.1.6. All interior non-bearing steel stud walls that extend above the ceiling but do not attach to the structure
above shall be braced with diagonal metal-stud braces (45°). The kl/r ratio of the brace shall not exceed200 and shall not be spaced further apart than 10'-0" on center. Connect diagonal braces to the top of thesteel stud walls and to the top flange of the steel beams with (2) #10 tek screws minimum. Where aconcrete deck occurs above, use two powder-driven fasteners per diagonal brace. Other approvedmethods may be used.
1.7. Anchor bolts: See steel section of general notes.2. Connection Hardware
2.1. Exterior framing shall be attached to primary structure to provide vertical and lateral drift as indicated inthese drawings. The "DriftTrack DTSL" by the Steel Network or equivalent is suitable to meet thisrequirement. Inside and outside corner joints shall be detailed to accommodate the lateral drift indicated.See architectural drawings for joint location and details.
2.2. All connection hardware (examples: "StiffClip", "VertiClip", "DriftClip", "BridgeClip", etc) shown shall besupplied by the Steel Network, Inc.
2.3. Install all hardware per the manufacturer's guidelines and recommendations.2.4. The contractor may submit an alternate connection method for approval by Dunn Associates, Inc. and the
Architect.
ABBREVIATIONS
AB Anchor BoltABV AboveALT AlternateARCH Architect
BFB Braced Frame BeamBFC Braced Frame ColumnBLDG BuildingBLW BelowBM BeamBOTT BottomBRB Buckling Restrained BraceBRDG BridgingBRG BearingBTW Between
CANT CantileveredCJ Control JointCJP Complete Joint PenetrationCL Center LineCMU Concrete Masonry Unit
JST Joist
K Kip(s) = 1000 PoundsKLF Kips Per Lineal FootKSF Kips Per Square Foot
LB Pounds (#)LOC Location
MAS MasonryMAX MaximumMECH MechanicalMEZZ MezzanineMFB Moment Frame BeamMFC Moment Frame ColumnMFR ManufacturerMIN MinimumMISC MiscellaneousMTL Metal
NTS Not To Scale
DEFERRED SUBMITTALS
1. Deferred submittals are items that are not part of our scope which require architectural and/or engineering review. Deferred submittals include plans, details, calculations and/or other relevant design information stamped by aProfessional Engineer licensed in the state in which construction will occur.
2. Deferred submittals shall first be submitted to the project architect and/or engineer for review and coordination.Upon completion of the architect/engineer review, the architect/engineer will submit the deferred submittals to theBuilding Official for review and approval. The submittal to the Building Official shall include a letter stating that thearchitect/engineer review has been performed and that the plans and calculations for the deferred submittal itemsare found to be in general conformance with the design drawings with no exceptions.
3. Construction related to deferred submittals shall not commence until the Building Official has approved thesubmittal. Approved deferred submittals shall be available at the jobsite throughout construction.
4. Items requiring deferred submittals are listed below. These items shall be designed and fabricated by themanufacturer according to specifications given in the construction documents.4.1. Open Web Steel Roof Joists and Girders (by steel joist manufacturer)4.2. Steel Ladders and stairs (by steel stair manufacturer). Suppliers to provide any additional required
support steel beyond that of the main building framing system shown on the design drawings.4.3. Seismic Bracing for mechanical, electrical and plumbing components per ASCE 7, Chapter 13 (by MEP
consultant)
5. Follow manufacturer and ICC evaluation report requirements for installation temperature of adhesive anchors.
5.2. Adhesive anchors in grouted masonry shall be5.2.1. HIT-HY 70 by Hilti (ESR-2682)5.2.2. AT-XP by Simpson (IAPMO UES ER-263)5.2.3. SET-XP by Simpson (IAPMO UES ER-265)5.2.4. ET-HP by Simpson (IAPMO UES ER-241)
6. Mechanical anchors6.1. Mechanical anchors in concrete shall be
6.1.1. Kwik Bolt TZ by Hilti (ESR-1917)6.1.2. Kwik HUS-EZ by Hilti (ESR-3027)6.1.3. Strong-Bolt 2 by Simpson (ESR-3037)6.1.4. Titen HD by Simpson (ESR-2713)6.1.5. Torq-cut by Simpson (ESR-2705)6.1.6. Trubolt+ by ITW (ESR-2427)6.1.7. Tapcon/Sammy Anchors by ITW (ESR-2202)6.1.8. Wedge-Bolt+ by Powers (ESR-2526)6.1.9. Power-Stud+ SD2 by Powers (ESR-2502)6.1.10. Power-Stud+ SD3, SD4 and SD6 Stainless by Powers (ESR-3471)6.1.11. Snake+ by Powers (ESR-2272)
6.2. Mechanical anchors in grouted masonry shall be6.2.1. Kwik Bolt 3 by Hilti (ESR-1385)6.2.2. Kwik HUS-EZ by Hilti (ESR-3056)6.2.2. Titen HD by Simpson (ESR-1056)6.2.3. Strong-Bolt 2 by Simpson (IAPMO ES ER-0240)6.2.3. Wedge-All by Simpson (ESR-1396)6.2.4. Power-Stud+ SD1 by Powers (ESR-2966)6.2.5. Wedge-Bolt+ by Powers (ESR-1678)
7. The Contractor may submit, for review and approval, the manufacturer's ICC evaluation report of alternate anchorsystems. The alternate method shall provide minimum capacities equal to or greater than those in the abovenoted anchors. The alternate method shall be approved by the engineer of record prior to the substitution.
Non-shrink grout shall be prepackaged, non-metallic and non-gaseous.
3.2. Provide full depth web stiffener plates at each side of all beams at all bearing points. Stiffener plates shallbe the thickness called out below unless noted otherwise. Stiffeners shall be welded on both sides of theplate-to-flange and plate-to-web interfaces. Do not weld into the web-to-flange fillet region of the member.FLANGE WIDTH----------------------------------------------- STIFFENER THICKNESS & WELD SIZELess than 8 1/4"------------------------------------------------ 1/4" & 3/16"8 1/4" to 12 1/4"------------------------------------------------ 3/8" & 1/4"12 1/4" to 16 1/2"----------------------------------------------- 1/2" & 5/16"16 1/2" to 20 3/4"----------------------------------------------- 5/8" & 3/8"
3.3. Bolting and Fasteners3.3.1. Ordinary steel-to-steel connections, simple span framing, and beam/girder-to-bearing plates
are the standard connection used throughout the design drawings, unless noted otherwise:3.3.1.1. Use A325N bolts or tension-controlled bolts.3.3.1.2. Tighten these fasteners to a "snug tight" condition.3.3.1.3. Where a steel-to-steel connection is not shown, provide a framed connection per
AISC for one half the total uniform load capacity of the beam for the span andsteel specified.
3.3.2. Fasteners and washers shall not be reused. Scrap dirty, rusted, or water-contaminated boltassemblies.
3.4. Weld Access Holes and Temporary Attachments3.4.1. Fabricate beam copes and weld access holes using the geometry described in AISC 360
Section J1.6.3.4.2. Runoff tabs are to be removed unless noted otherwise.
3.5. Backup Bars: Remove backup bars from all beam bottom flange connections in demand critical welds,unless noted otherwise. Backgouge the root and weld to sound metal. Reweld the gouged area and adda 5/16" reinforcing fillet weld.
3.6. Protected Zones: No connections, other than those on the design drawings, shall be made within theprotected zone of the SLRS as identified in AISC 341.3.6.1. Locate headed studs, welds, miscellaneous metal, etc outside of the protected zone.3.6.2. Paint the protected zones with bright paint before and after fire coating operations to identify
them.3.7. All welds not noted on drawings shall be minimum 1/4" fillet welds.3.8. All structural steel members shall be considered as an unrestrained fire-resistance-rated assembly.
4. Welding of Reinforcing Steel or Bolts4.1. Reinforcing Bars: Do not weld rebar except as specifically detailed in the drawings. In such cases, use
only AWS standards. Do not substitute reinforcing bars for deformed bar anchors, structural bolts, orheaded stud anchors.
4.2. Do not weld anchor bolts, including "tack" welds.4.3. Headed Stud Anchor welding and Deformed Bar Anchor welding shall conform to the manufacturer's
specifications.
COL ColumnCONC ConcreteCONN ConnectionCONT ContinuousCOORD CoordinateCTR Center
DB Deck BearingDBA Deformed Bar AnchorDBL DoubleDCW Demand Critical WeldDET DetailDIA DiameterDIM DimensionDWG Drawing
(E) ExistingEA EachEF Each FaceEL ElevationELEC ElectricalENGR EngineerEQ EqualEQUIP EquipmentEQ SP Equally SpacedEW Each WayEJ Expansion JointEXT Exterior
FLR FloorFND FoundationFTG Footing
ga GageGALV GalvanizedGSN General Structural Notes
HORIZ HorizontalHSA Headed Stud AnchorHSS Hollow Structural Section
IBC International Building CodeICC International Code CouncilINT Interior
oc On CenterOPNG OpeningOPP Opposite
PCF Pounds per Cubic FootPEN Penetrate or PenetrationPERP PerpendicularPJP Partial Joint PenetrationPL PlatePLF Pounds per Lineal FootPREFAB PrefabricatedPSF Pounds per Square FootPSI Pounds per Square Inch
REINF ReinforceREQD RequiredRTU Roof Top Unit
SCHED ScheduleSFRS Seismic Force Resisting SystemSIM SimilarSOG Slab on GradeSTD StandardSTIFF StiffenerSTL SteelSTRUCT StructuralSW Shear Wall
T&B Top and BottomTEMP TemperatureTHRU ThroughT/ Top ofTYP Typical
UNO Unless Noted Otherwise
VERT Vertical
W/ WithWWR Welded Wire ReinforcementWP Working Point
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:09:1
4 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
BDR09.09.2016
16073
GENERAL
STRUCTURAL
NOTES
S101
09.09.2016PERMIT SET
GENERAL STRUCTURAL NOTES
Permit Set
This set is submitted as a complete set of structural drawings to be reviewed by the City orGoverning Jurisdiction responsible for issuing a Building Permit. Upon their final review and re-submittal of these drawings it is understood that this set will be re-issued for General Contractorpricing. The General Contractor is not to provide a GMP off this submittal.
# Date Revision
SPECIAL INSPECTION, TESTING AND STRUCTURAL OBSERVATION REQUIREMENTS
1. Special Inspections and Testing1.1. Special inspections and testing as required per the construction documents and per IBC Chapter 17 shall
be provided for this project unless waived by the Building Official.1.2. An independent agency/agencies employed by the Owner, shall perform the special inspection and testing
services required.1.3. The special inspection and testing requirements of this section of the General Structural Notes and the
special inspection tables serve as the Engineer of Record's statement of special inspections and structuralobservations required by IBC Chapter 17.
2. Contractor Responsibilities2.1. Each Contractor responsible for the construction of a main wind or seismic force-resisting system, a
designated seismic system, or a wind or seismic force-resisting component shall submit a writtenstatement of responsibility to the Building Official and Owner prior to commencing with the work involved.It shall contain acknowledgement of awareness of the special inspection and testing requirements.
2.2. The Contractor shall coordinate and cooperate with all the required inspections, testing, and/or structuralobservations required for the project. The Contractor shall not proceed with subsequent work untilrequired inspections, testing, and/or structural observations have been provided.
2.3. The Contractor shall correct all work found to be deficient, and re-test at no additional cost to the Owner.2.4. The Contractor shall notify the Engineer of Record at least (7) days prior to any required structural
observations.2.5. Submit all required documentation to the Special Inspector for review.
3. Special Inspector Responsibilities3.1. Each Special Inspector shall be a qualified person who shall demonstrate competence and relevant
experience or training, to the satisfaction of the Building Official, for the inspection of the particular type ofconstruction or operation requiring special inspection.
3.2. Special Inspectors shall keep records of their inspections.3.3. Inspection reports shall indicate whether the work inspected was or was not completed in accordance with
the construction documents and the referenced building codes.3.4. Non-conforming work and/or discrepancies shall be brought to the Contractor's immediate attention for
correction.3.5. The Special Inspector shall notify the Architect/Engineer of any non-conforming work or discrepancies that
the Contractor cannot readily correct.3.6. Any uncorrected non-conforming work or discrepancies shall be brought to the attention of the
Architect/Engineer and the Building Official prior to completion of that phase of the work.3.7. Submit the following to the Building Official:
3.7.1. Special Inspections and Testing Reports.3.7.2. Certificates of Compliance for:
3.7.2.1. Fabrication of structural elements from approved fabricators.3.7.2.2. The seismic qualifications of nonstructural components, supports, and
attachments.3.7.2.3. Designated Seismic Systems.3.7.2.4. Open-web steel joists and joist girders.
3.7.3. Reports of:3.7.3.1. Pre-construction tests for shotcrete.3.7.3.2. Material properties verifying compliance with the requirements of AWS D1.4 for
weldability for reinforcing bars other than ASTM A706.3.7.3.3. Mill tests for ASTM A615 reinforcing bars used to resist earthquake induced
forces in special moment frames, special structural walls or coupling beams instructures assigned to Seismic Design Category B, C, D, E, or F.
4. Quality Control Submittals for Structural Steel4.1. Provide Level III non-destructive testing (NDT) personnel certifications.4.2. Provide welder qualification records to verify project welders are tested and qualified in accordance with
AWS D1.1 before welding structural or miscellaneous steels, D1.3 before welding sheet steels (10 gaugeand thinner), and D1.4 before welding reinforcing steel. Submit documentation to the approved inspectionagency for review before welding.4.2.1. Special, restricted welder qualification testing is required for welders joining the bottom-flange
through the weld access hole connection in demand critical welds. Qualify welders for theminimum groove angle and maximum deposition rate used in production. Follow theinstructions for supplemental qualification testing in AWS D1.8, Section 5.1. Qualificationtesting must take place within two years from the start of this project.
4.3. Provide welder identification methodology. The fabricator/erector shall maintain a system by which thewelder who has welded a joint or member can be identified. Stamps, if used, shall be the low stress type.
4.4. Provide welding procedures that comply with AWS D1.1, D1.3, D1.4, D1.8, as required by the project.Welding procedures shall be made available to welders and inspectors.4.4.1. Provide weld filler metal product data sheets identifying optimum welding parameters and
storage conditions with each welding procedure submittal.4.4.2. Identify the maximum welding heat input per inch of weld (KJ/in) permitted by the welding
procedures.4.4.3. Identify the maximum deposition rate that will be used while welding on any demand critical
weld.4.4.4. Provide typical welding filler metal Certificates of Conformance that identify the WPS Heat
Input Envelope.4.5. Provide a preliminary welding repair procedure to follow should welding repairs be required within the
Seismic Protected Zone.4.6. Provide mill/material test reports (MTR) or certificates of conformance (CC) that verify compliance of
furnished materials to the requirements of the approved contract documents. MTRs or CCs are requiredfor structural shapes, plate, metal deck, fasteners, headed studs, DBAs, weld filler metal, and boltassemblies used as primary, load-bearing members. Maintain the heat number traceability of structuralshapes and plate used as primary, load bearing members.
5. Structural Steel Non-Destructive Testing (NDT) Personnel Qualifications5.1. NDT personnel will:
5.1.1. Qualify in accordance with the recommended practices of the American Society ofNondestructive Testing, SNT-TC-1A, latest edition.
5.1.2. Pass eye examinations meeting: (1) ASTM requirements at least once a year, and (2) AWSD1.1 every three years.
5.1.3. Be certified in accordance with the AWS QC-1, latest edition.5.1.4. Level III must be qualified by ASNT testing in the applicable method under review.
5.2. Only Level II and Level III technicians, qualified by testing in the applicable method, are permitted tointerpret nondestructive testing results.
5.3. Only Senior Certified or Certified Welding Inspectors (SCWI, CWI) are permitted to evaluate welds.Certified Associate Welding Inspectors may evaluate welds when under the direct supervision of a SCWIand/or CWI.
5.4. Approved Inspection Agency will certify the following:5.4.1. Level III inspector has reviewed the NDT procedures5.4.2. Project ultrasonic testing technicians, testing demand critical welds, are trained and qualified
in accordance with AWS D1.8, Annex E5.4.3. That the Inspection Agencies' ultrasonic testing procedures are qualified by weld mockups
similar to AWS D1.1, Annex S.6. Special Inspections
6.1. Fabricated Items (1704.2.5): Where fabrication of structural, load bearing or lateral load-resisting membersor assemblies is being conducted on the premises of a fabricator's shop, special inspections of thefabricated items shall be performed during fabrication. Special inspections during fabrication are notrequired where the work is done on the premises of a fabricator registered and approved by the buildingofficial to perform such work without special inspection. At the completion of fabrication, the approvedfabricators shall submit a certificate of compliance to the Owner for submittal to the Building Official.
6.2. Structural Steel: Special inspection and non-destructive testing (NDT) are required during the fabricationand erection of any load-bearing members and assemblies. Special inspection, except NDT, may bewaived when the work is performed in a fabricating shop, or by an erector approved by the BuildingOfficial to perform work without Special Inspection. NDT of welds completed in an approved fabricator'sshop may be performed by the fabricator when approved by the Building Official. When the fabricatorperforms the NDT, the fabricator shall submit the NDT reports for review by the Special Inspector. Specialinspection and NDT shall be provided per the special inspection tables for structural steel in theconstruction documents.6.2.1. Perform all welding and welding special inspection activities in accordance with AWS D1.1,
D1.3, D1.4, and D1.8, AISC 360 Chapter N, and AISC 341 Chapter J, as appropriate for thematerial form and welding methods employed. Approved methods and acceptance criteriaare established in these codes.
6.2.2. Perform all bolting and bolting inspection activities in accordance with AISC 360 Specificationfor Structural Steel Buildings Using A325 and A490 Bolts, AISC 360 Chapter N, and AISC341 Chapter J, as applicable.
6.2.3. Non-Destructive Testing (NDT) of welds is required as follows:6.2.3.1. Ultrasonic testing (UT), magnetic particle testing (MT), penetrant testing (PT),
and radiographic testing (RT), where required, shall be performed in accordancewith AWS D1.1/D1.1M. Acceptance criteria shall be in accordance with AWSD1.1/D1.1M for statically loaded structures, unless otherwise designated on thedesign drawings or project specifications.
6.2.3.2. All NDT shall be documented. NDT reports shall be distributed to thefabricator/erector, the Building Official, the Contractor, and the Architect.
6.2.3.3. Amount of NDT is permitted to be reduced according to AISC 360 Chapter N andAISC 341 Chapter J if appropriate criteria are met, and if approved by theBuilding Official and the Engineer of Record.
6.2.3.4. Requirements for structures in Seismic Design Categories C thru F:6.2.3.4.1. Ultrasonic test all complete joint penetration groove6.2.3.4.2. Magnetic particle test or penetrant test all thermally cut surfaces ofaccess holes for flange or web thicknesses exceeding 2”. Magnetic particle testor penetrant test all thermally cut surfaces of beam copes access holes for flangeor web thicknesses exceeding 1 ½” for members of the seismic force resistingsystem in Seismic Design Categories C thru F. Any crack shall be deemedunacceptable.
6.2.4. Special inspections and Testing for Non-Shrink Grout are required as follows:6.2.4.1. Periodic special inspection verifying the use of required mix design.6.2.4.2. Samples of non-shrink grout shall be tested for compressive strength at least
daily, with additional tests required for each additional 10 bags mixed per day.6.3. Steel Construction (1705.2): The special inspections and nondestructive testing of steel construction in
buildings shall be in in accordance with the following:6.3.1. Structural Steel. Special inspections and non-destructive testing of structural steel elements
in buildings, structures, and portions thereof shall be in accordance with the QualityAssurance inspection requirements of AISC 360 and tables in the construction documents.
6.3.2. Cold-Formed Steel Deck. Special inspections and qualification of welding special inspectorsfor cold-formed steel floor and roof deck shall be in accordance with the Quality Assurance
or penetrant test all thermally cut surfaces of beam copes access holes for flange
6.3.2. Cold-Formed Steel Deck. Special inspections and qualification of welding special inspectorsfor cold-formed steel floor and roof deck shall be in accordance with the Quality Assuranceinspection requirements of SDI QA/QC.
6.3.3. Open-Web Steel Joists and Joist Girders. Special inspections of open-web steel joists andjoist girders in buildings, structures, and portions thereof shall be in accordance with Table1705.2.3 in the construction documents.
6.3.4. Cold-Formed Steel Trusses Spanning 60 Feet or Greater. The special inspector shall verifythat the temporary installation restraint/bracing and the permanent individual truss memberrestraint/bracing are installed in accordance with the approved truss submittal package.
6.4. Concrete (1705.3): Special inspections and tests of concrete construction shall be performed inaccordance with Table 1705.3 in the construction documents.6.4.1. Special inspections of welding of and qualifications of special inspectors for reinforcing bars
shall be in accordance with the requirements of AWS D1.4 for special inspections and forspecial inspector qualifications.
6.4.2. In the absence of sufficient data or documentation providing evidence of conformance toquality standards for concrete materials, the building official shall require testing inaccordance with the appropriate standards and criteria for the materials.
6.5. Masonry (1705.4): Special inspections and tests of masonry construction shall be performed inaccordance with the Qualtiy Assurance program requirements of ACI 530 and 530.1.6.5.1. Engineered masonry and vertical masonry foundation elements in Risk Categories I, II and III
shall be special inspected per Table 3.1.2- Masonry Level B Quality Assurance in theconstruction documents.
6.6. Soils (1705.6): Special inspections and tests of existing site soil conditions, fill materials, placement, andload-bearing requirements shall be performed in accordance with the approved soils report and Table1705.6 in the construction documents. The Special Inspector shall verify that proper materials andprocedures are used. The approved geotechnical report and the construction documents shall be used todetermine compliance
6.7. Post-Installed Anchors: Special inspections and tests shall be performed during installation ofpost-installed anchors according to the requirements of the ICC Evaluation Report and table 1705.3 in theconstruction documents.
6.8. See architectural drawings for additional required inspections pertaining to sprayed fire-resistant materials(1705.14), mastic and intumescent fire-resistant coatings (1705.15), EIFS (1705.16), fire resistantpenetrations and joints (1705.17), or smoke control systems (1705.18).
7. Special Inspections for Seismic Resistance (1705.12): Special inspections for seismic resistance are requiredfor this project per IBC section 1705.12. Provide as follows:7.1. Structural Steel (1705.12.1): Special Inspections for seismic resistance shall be in accordance with the
following as applicable:7.1.1. Seismic Force-Resisting Systems; Special Inspections of structural steel in the seismic
force-resisting systems of buildings and structures assigned to Seismic Design Category B, C,D, E, or F shall be performed in accordance with the Quality Assurance requirements of AISC341 and the construction documents.
7.1.2. Structural Steel Elements; Special Inspections of structural steel elements in the seismicforce-resisting systems of buildings and structures assigned to Seismic Design Category B, C,D, E, or F other than those covered in section7.1.1 above, including struts, collectors, chords,and foundation elements, shall be performed in accordance with the Quality Assurancerequirements of AISC 341 and the construction documents.
7.2. Designated Seismic Systems (1705.12.4): For structures assigned to Seismic Design Category C, D, E, orF, the Special Inspector shall examine designated seismic systems requiring seismic qualifications inaccordance with ASCE7 Section 13.2.2, and verify that label, anchorage and mounting conforms to thecertificate of compliance.
7.3. Architectural Components (1705.12.5): Periodic special inspection is required for the erection andfastening of exterior cladding, interior and exterior nonbearing walls and interior and exterior veneer instructures assigned to Seismic Design Category D, E, or F.7.3.1. Access Floors. Periodic special inspection is required for the anchorage of access floors in
structures assigned to Seismic Design Category D, E, or F.7.4. Plumbing, Mechanical, and Electrical Components (1705.12.6): Periodic special inspection of plumbing,
mechanical, and electrical components shall be required for the following:7.4.1. Anchorage of electrical equipment for emergency and standby power systems in structures
assigned to Seismic Design Category C, D, E, or F.7.4.2. Anchorage of other electrical equipment is structures assigned to Seismic Design Category E
or F.7.4.3. Installation and anchorage of piping systems designed to carry hazardous materials and their
associated mechanical units in structures assigned to Seismic Design Category C, D, E, or F.7.4.4. Installation and anchorage of ductwork designed to carry hazardous materials in structures
assigned to Seismic Design Category C, D, E, or F.7.4.5. Installation and anchorage of vibration isolated systems in structures assigned to Seismic
Design Category C, D, E, or F where the approved construction documents require a nominalclearance of 1/4” or less between the equipment support frame and restraint.
8. Testing for Seismic Resistance (1705.13): Testing for seismic resistance is/is not required for this project perIBC section 1705.13. Provide as follows:8.1. Structural Steel (1705.13.1):
8.1.1. Seismic Force-resisting Systems. Non-destructive testing of structural steel in the seismicforce-resisting systems of structures assigned to Seismic Design Category B, C, D, E, or Fshall be performed in accordance with the Qualtiy Assurance requirements of AISC 341.
8.1.2. Structural Steel Elements. Non-destructive testing of structural steel elements in the seismicforce-resisting systems of structures assigned to Seismic Design Category B, C, D, E, or Fshall be performed in accordance with the Qualtiy Assurance requirements of AISC 341.
8.2. Non-Structural Components (1705.13.2): For structures assigned to Seismic Design Category B, C, D, E,or F where the requirements of ASCE 7 Section 13.2.1 for nonstructural components, supports orattachments are met by seismic qualification as specified in Item #2 therein, the registered designprofessional of the applicable discipline shall specify on the approved construction documents therequirements for seismic qualification by analysis, testing, or experience data. Certificates of Compliancefor the seismic qualification shall be submitted to the Building Official.
8.3. Designated Seismic Systems (1705.13.3): For structures assigned to Seismic Design Category C, D, E,or F and with designated seismic systems that are subject to the requirements of ASCE 7 Section 13.2.2for certification, the registered design professional of the applicable discipline shall specify on theapproved contract documents the requirements to be met by analysis, testing, or experience data asspecified therein. Certificates of Compliance documenting that the requirements are met shall besubmitted to the Building Official.
9. Special Inspections for Wind Resistance (1705.11): Special inspections for wind resistance are not required forthis project per IBC Section 1705.11.
10. Structural Observations/Site Observations (1704.6): Structural observations are required for this project per IBCsection 1704.6.10.1. The Engineer of Record or his representative shall perform the structural observations as required.10.2. A registered design professional employed by the Owner shall perform the structural observations as
required.10.3. Structural Observations of the following stages of construction shall be provided. The Contractor shall
notify (in writing) the [EOR/design professional] performing the structural observations at least 7 days priorto the following stages of construction so that they may have the opportunity to review the work. At theconclusion of the work, a site observation report will be provided stating that the site visits have beenmade and report any unresolved deficiencies.10.3.1. Initial placing of any concrete, including but not limited to: footings, shear walls, or slabs on
grade.10.3.2. Initial grout pours for masonry walls10.3.3. Initial erection of structural steel10.3.4. Completion of structural roof deck10.3.5. Initial finish work
10.4. Structural observation/Site observation reports will be provided to the Architect. Distribution to theContractor, Owner, and/or Building Official will be through the Architect.
11. Seismic/Wind Main Force Resisting Systems That Require Special Inspections11.1. Masonry Shear Walls11.2. Steel Moment Frames11.3. Metal Roof Deck
WOOD
1. Materials1.1. Dimension Lumber and Timbers (Sawn Lumber)
1.1.1. All dimensioned lumber shall comply with USDOC PS20.1.1.2. Visually graded dimension lumber shall be Douglas Fir-Larch #2 or better.1.1.3. Visually graded timbers (5" x 5" and larger) shall be Douglas Fir-Larch #1 or better.1.1.4. Machine stress rated (MSR) lumber shall be 1600f-1.6E or better.1.1.5. Approved end jointed lumber may be used interchangeably with solid sawn members of the
same species and grade.1.2. Laminated Veneer Lumber (LVL) and Rim Board
1.2.1. All LVL shall be a minimum of 1 3/4" thick with the following design values in psi: Fb = 2600,E = 2.0x10^6, Fcperp=750, Fv = 285, Fcpar =2510, Ft = 1555).
1.2.2. All rim boards shall be a minimum of 1 1/2" thick . See bearing wall schedule for verticalcapacity requirements.
1.2.3. Handle, store and install all LVL per the manufacturer's guidelines.1.2.4. Connect multiple members together per the manufacturer's guidelines.1.2.5. LVL, LSL and Rim Board of equal design properties as determined by ASTM D5456 may be
substituted with written approval from Dunn Associates, Inc.1.3. Wood Structural Panel Sheathing
1.3.1. Wood structural panels shall conform to the requirements for its type in USDOC PS1 orUSDOC PS2. The panels must be identified by the trademarks of the approving testing andinspection agency.
1.3.2. Wood sheathing shall be APA rated sheathing Exposure 1 unless noted otherwise. See plansand schedules for thickness and span rating.
1.4. Nails1.4.1. All Nails shall conform to the requirements specified in ASTM F1667, "Standard Specification
of Driven Fasteners: Nails, Spikes and Staples."1.4.2. All nails shall be common nails with the following properties:
Nail------------------Shank Diameter--------------------------------Min. Penetration into Support6d--------------------0.113"--------------------------------------------1.25"8d--------------------0.131"--------------------------------------------1.50"10d-------------------0.148"--------------------------------------------1.63"12d-------------------0.148"--------------------------------------------1.63"16d-------------------0.162"--------------------------------------------1.75"Nails with properties less then those listed above shall not be used without prior writtenapproval from Dunn Associates, Inc.
1.4.3. Nails with "T", brad, finish or casing heads are not permitted. Nails with Round (full), Offset,Oval, Clipped or Notched heads are acceptable.
1.4.4. Deformed shank nails shall have either a helical (screw) or an annular (ring) shank.1.5. Bolts
1.5.1. Anchor Bolts: ASTM F1554 Grade 36 (or A307 Grade A/C or A36)1.5.2. All anchor bolts connecting shearwall sill plates to the concrete foundation shall have a
PL1/4"x3"x3" washer between the sill plate and the nut, UNO. See the shear wall schedule.1.5.3. Connection Bolts: ASTM A307 Grade A/C or ANSI Standard B18.2.1.1.5.4. Bolt holes shall be a minimum of 1/32" to a maximum of 1/16" larger than the bolt diameter.
Holes shall be accurately aligned in main members and side plates or side members. Boltsshall not be forcibly driven.
1.5.5. At all bolted connections, provide a standard cut or larger washer or metal plate between thewood and the bolt head and between the wood and the nut.
1.6. Connection Hardware1.6.1. All connection hardware shown shall be supplied by Simpson Strong-Tie Incorporated.1.6.2. Install all hardware per the manufacturer's guidelines.1.6.3. Connection hardware of equal design properties, including USP Structural Connectors or
other manufacturers may be substituted with written approval from Dunn Associates, Inc.1.7. Continuous Rod Hold Down systems
1.7.1. Maximum rod elongation shall be limited to 1/8", or as required by building official.1.7.2. Maximum total system elongation (rod, take-up device, couplers, bearing plate, and plate
crushing) shall be limited to 0.2", as shown by calculation, or as required by building official.1.7.3. Systems shall anchor at each floor level and/or point of lateral reaction. Skipping of floors is
not permitted.1.7.4. An ICC or IAPMO approved take-up device shall be provided at every level and
accommodate 1/8" shrinkage per level for engineered wood floor framing, or 1/4" shrinkageper level for solid sawn floor trusses.
2. All fasteners in contact with preservative-treated or fire-treated wood shall be hot-dipped zinc-coated galvanizedor stainless steel.
3. All wood in contact with concrete, masonry or soil shall be preservative-treated or redwood.4. General framing and carpentry shall be connected as per "THE MINIMUM NAILING SCHEDULE" unless noted
otherwise.5. Provide solid shaped blocking at least 2" (nominal) thick and full depth of joist at ends and at each support of joist.
Provide approved bridging at an 8'-0" on center maximum between joist end supports.6. All bearing and shear walls shall have a minimum of 2 top plates. See details for splices in top plates.7. Provide a double joist under parallel partitions.8. Solid blocking at eaves may be omitted where required for ventilation (1 block in 5 blocks), UNO.9. Holes or penetrations through bearing walls shall be limited to the clear space between studs. Holes in shear wall
sheathing shall be limited to 6" diameter (max), spaced at a minimum of 3 diameters on center. The maximumaccumulated length of openings in a shear wall shall not exceed 20% of the wall length, UNO.
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:09:1
5 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
Author09.09.2016
16073
GENERAL
STRUCTURAL
NOTES
S102
09.09.2016PERMIT SET
# Date Revision
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC
TABLE 1705.6: REQUIRED VERIFICATION AND INSPECTION OF SOILS
VERIFICATION AND INSPECTION TASK CONTINUOUS DURING TASK LISTED PERIODIC DURING TASK LISTED
TABLE 1705.2.2: REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTIONOTHER THAN STRUCTURAL STEEL
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC REFERENCED STANDARD IBCREFERENCE
TABLE 1705.3: REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
REFERENCED STANDARD IBC REFERENCE
a
a
REQUIRED VERIFICATION AND INSPECTION OF STRUCTURAL STEEL CONSTRUCTIONPRIOR TO BOLTING OR WELDING
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC REFERENCED STANDARD
REQUIRED VERIFICATION AND INSPECTION OF STRUCTURAL STEEL CONSTRUCTIONDURING BOLTING OR WELDING
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC REFERENCED STANDARD
REQUIRED VERIFICATION AND INSPECTION OF STRUCTURAL STEEL CONSTRUCTIONAFTER BOLTING OR WELDING
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC REFERENCED STANDARD
TABLE 1.19.2: MASONRY LEVEL B QUALITY ASSURANCERISK CATEGORY I, II, AND III ENGINEERED MASONRY
INSPECTION TASK FREQUENCY
PERIODIC
REFERENCE FOR CRITERIA
MINIMUM TESTS
MINIMUM INSPECTION
CONTINUOUS TMS 402 /ACI 530 /ASCE 5
TMS 602 /ACI 530.1 /
ASCE 6
- X -
- X -
- X
X -
- X
X
- -
- X
- X
- X
- X
X -
X -
- X
-
- X
X
- X
-
X -
- X
- X
1. Material verification of cold-formed steel deck:
AWS D1.4ACI 318: Section 3.5.2
1. Verify materials below shallow foundations are adequate to achieve thedesign bearing capacity.
2. Verify excavations are extended to proper depth and have reached propermaterial.
3. Perform classification and testing of compacted fill materials.
4. Verify use of proper materials, densities and lift thicknesses during placementand compaction of compacted fill.
5. Prior to placement of compacted fill, observe subgrade and verify that sitehas been prepared properly.
Applicable ASTM materialstandards
For SI: 1 inch = 25.4 mm.a. Where application, see also Section 1705.11. Special inspection for seismic resistance.
1. Inspection of reinforcing steel, including prestressingtendons and placement.
2. Inspection of reinforcing steel welding in accordancewith Table 1705.2.2, Item 2b
3. Inspection of anchors cast in concrete where allowable loads havebeen increased or where strength design is used.
5. Verifying use of required design mix.
6. At the time fresh concrete is sampled to fabricate specimens forstrength tests, perform slump and air content tests, anddetermine the temperature of the concrete.
7. Inspection for maintenance of specified curing temperatureand techniques.
8. Verification of in-situ concrete strength, prior to stressing of tendonsin post-tensioned concrete and prior to removal of shores and formsfrom beams and structural slabs.
9. Inspect formwork for shape, location and dimensions of the concretemember being formed.
ACI 318: 6.1.1
ACI 318: 6.2
ACI 318: 5.11-5.13
ASTM C 172ASTM C 31
ACI 318: 5.6, 5.8
ACI 318: Ch 4, 5.2-5.4
AWS D1.4ACI 318: 3.5.2
ACI 318: 3.5, 7.1-7.7 1910.4
1908.5, 1909.1
1904.2, 1910.21910.3
1910.10
1910.9
AWS D1.3
ACI 318; 8.1.3,21.1.8
- X4. Inspection of anchors post-installed in hardened concrete members. ACI 318: 3.8.6, 8.1.3, 21.1.8 1909.1
For SI: 1 inch = 25.4 mm.a. Where application, see also Section 1705.11. Special inspection for seismic resistance.b. Specific requirements for special inspection shall be included in the research report for anchor issued by an approved source in accordance
with ACI 355.2 or other qualification procedures. Where specific requirements are not provided, special inspection requirements shallbe specified by the registered design professional and shall be approved by the building official prior to commencement of the work.
b
-X
-X
-X
1. Required Special Inspections prior to bolting or welding
a. Verify welding procedure specifications are available AISC 360-10 Table N5.4-1
b. Observe and document Reduced Beam Section requirements ifapplicable (Contour, finish and dimensional tolerances)
a. Verify connecting elements, including the appropriate fayingsurface condition and hole preparation, if specified, meet theapplicable requirements
2. Additional required Special Inspections prior to bolting or welding inSeismic Design Categories C thru F
b. Verify manufacturer's certifications for welding consumables is available AISC 360-10 Table N5.4-1
X-c. Verify material type/grade AISC 360-10 Table N5.4-1 and AISC 341-10 Table J6-1
X-d. Verify fabricator or erector has a system by which a welder who weldeda joint or member can be identified
AISC 360-10 Table N5.4-1 andAISC 341-10 Table J6-1
e. Verify the following for the fit-up of groove welds (including jointgeometry)
AISC 360-10 Table N5.4-1 andAISC 341-10 Table J6-1
X-1) Joint preparation
X-2) Dimensions (alignment, root opening, root face, bevel)
X-3) Cleanliness (condition of steel surfaces)
X-
4) Tacking (tack weld quality and location)
g. Verify the following for the fit-up of fillet welds
X-1) Dimensions (alignment, gaps at root)
5) Backing type and fit (if applicable)
X-
X-
f. Verify the configuration and finish of access holes
2) Cleanliness (condition of steel surfaces)
3) Tacking (tack weld quality and location)
AISC 360-10 Table N5.4-1 and AISC 341-10 Table J6-1
AISC 360-10 Table N5.4-1 and AISC 341-10 Table J6-1
X-
X-
-Xh. Verify manufacturer's certifications available for fasteners AISC 360-10 Table N5.6-1
X-i Verify fasteners are marked in accordance with ASTM requirements AISC 360-10 Table N5.6-1
X-j. Verify proper fasteners are selected for the joint detail (grade, type)
X-k. Verify proper procedure selected for joint detail
X-l. Observe and document pre-installation verification testing byinstallation personnel for fastening assemblies and methods used.
AISC 360-10 Table N5.6-1 andAISC 341-10 Table J7-1
X-
m. Verify proper storage is provided for bolts, nuts, washers and otherfastener components.
AISC 341-10 Table J7-1
AISC 360-10 Table N5.6-1 and AISC 341-10 Table J7-1
AISC 360-10 Table N5.6-1 and AISC 341-10 Table J7-1
AISC 341-10 Table J8-1
X- AISC 360-10 Table N5.6-1 andAISC 341-10 Table J7-1
1) Packing
2) Exposure Control
AISC 360-10 Table N5.4-2 and AISC 341-10 Table J6-2a. Verify use of qualified welders
AISC 360-10 Table N5.4-2 and AISC 341-10 Table J6-2b. Verify the control and handling of consumables
X-
X-
X-
c. Verify no welding occurs over cracked tack welds X- AISC 360-10 Table N5.4-2 and AISC 341-10 Table J6-2
d. Verify environmental conditions AISC 360-10 Table N5.4-2 and AISC 341-10 Table J6-2
X-
X-
1) Wind speed within limits
2) Precipitation and temperature
e. Verify weld specification procedures are followed AISC 360-10 Table N5.4-2 and AISC 341-10 Table J6-2
X-
X-
1) Settings on weld equipment
2) Travel speed X-
X-3) Selecting weld materials -
4) Shielding gas type/flow rate X-
5) Preheat applied X-
6) Interpass temperature maintained (min/max) X-
X-7) Proper position (F, V, H, OH)
f. Verify welding techniques AISC 360-10 Table N5.4-2 and AISC 341-10 Table J6-2
X-1) Interpass and final cleaning
2) Each pass within profile limitations X-
3) Each pass meets quality requirements X-
g. Verify fastener assemblies, of suitable condition, are placed in all holesand washers are positioned as required
AISC 360-10 Table N5.6-2 andAISC 341-10 Table J7-2
h. Verify joints are brought to the snug-tight condition prior to thepretensioning operation
AISC 360-10 Table N5.6-2 andAISC 341-10 Table J7-2
X-
X-
i. Verify fastener components not turned by the wrench are preventedfrom rotating
AISC 360-10 Table N5.6-2 andAISC 341-10 Table J7-2
X-
j. Verify fasteners are pretensioned in accordance with RCSCSpecification progressing from the most rigid point toward the free edges
AISC 360-10 Table N5.6-2 andAISC 341-10 Table J7-2
X-
2. Additional required Special Inspections during bolting or welding in SeismicDesign Categories C thru F
a. Verify intermix of filler metals avoided unless approved AISC 341-10 Table J6-2X-
1. Note: Special inspection is not required during bolting of snug tight connections2. Note: Special inspection is not required during bolting for pretensioned joints or slip-critical joints when installer
is using the turn-of-nut method with matchmarking techniques, the direct tension indicator method, or twist-off-type tension control bolt method
1. Required Special Inspections after bolting or welding
a. Verify welds are cleaned AISC 360-10 Table N5.4-3 and AISC 341-10 Table J6-3X-
b. Verify size, length and location of welds AISC 360-10 Table N5.4-3 and AISC 341-10 Table J6-3-X
c. Verify welds meet visual acceptance criteria AISC 360-10 Table N5.4-3 and AISC 341-10 Table J6-3
1) Crack prohibition
2) Weld/base metal fusion
3) Crater cross section
4) Weld profiles
5) Undercut
6) Porosity
-X
-X
-X
-X
-X
-X
d. Inspect arc strikes for cracks AISC 360-10 Table N5.4-3-X
e. Visually inspect the web k-area for cracks within 3" of webdoubler plates and stiffeners
AISC 360-10 Table N5.4-3-X
f. Verify backing bars removed (if required) and weld tabs removed AISC 360-10 Table N5.4-3 and AISC 341-10 Table J6-3-X
g. Observe repair activities -X
h. Document acceptance or rejection of welded joint or member andbolted connections
-X
i. Verify structural steel framing is in compliance with details shown onthe Construction Documents, including bracing, stiffeners, memberlocations, and proper application of joint details at each connection
X
AISC 360-10 Table N5.4-3 and AISC 341-10 Table J6-3
AISC 360-10 Table N5.6-3
AISC 360-10 Chapter N-
2. Additional required Special Inspections after bolting or welding in SeismicDesign Categories C thru F
a. Verify placement of reinforcing or contouring fillet welds (if required) AISC 341-10 Table J6-3
b. Verify placement of backing fillet welds (if required) AISC 341-10 Table J6-3-X
c. Inspect and document protected zones have no holes andunapproved attachments
AISC 341-10 Table J8-1-X
-X
1. Required Special Inspections during bolting or welding1, 2
Verification of Slump flow and Visual Stability Index (VSI) as delivered to the project site inaccordance with Specification Article 1.5 B.1.b.3 for self consolidating grout.
2. As masonry construction begins, verify that the following are in compliance:
b. Construction of mortar joints
a. Proportions of site-prepared mortar
1. Verify compliance with the approved submittals
c. Grade and size of prestressing tendons and anchorages
d. Location of reinforcement, connectors, and prestressing tendons andanchorages
e. Prestressing technique
f. Properties of thin-bed mortar for AAC masonry
3. Prior to grouting, verify that the following are in compliance:
a. Grout space
b. Grade, type, and size of reinforcement and anchor bolts, andprestressing tendons and anchorages
c. Placement of reinforcement, connectors, and prestressing tendonsand anchorages
d. Proportions of site-prepared grout and prestressing grout for bondedtendons
e. Construction of mortar joints
4. Verify during construction:
a. Size and location of structural elements
b. Type, size, and location of anchors, including other details of anchorageof masonry to structural members, frames, or other construction
c. Welding of reinforcement
d. Preparation, construction, and protection of masonry during coldweather (temperature below 40°F (4.4°C)) or hot weather(temperature above 90°F (32.2°C))
e. Application and measurement of prestressing force
f. Placement of grout and prestressing grout for bonded tendons is incompliance
g. Placement of AAC masonry units and construction of thin-bedmortar joints
5. Observe preparation of grout specimens, mortar specimens, and/or prisms
(a) Frequency refers to the frequency of inspection, which may be continuous during the task listed or periodically during the listed task, as defined in the table.(b) Required for the first 5000 square feet (465 square meters) of AAC masonry.(c) Required after the first 5000 square feet (465 square meters) of AAC masonry.
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
(b) (c)
(b) (c)
Art. 3.3 F
Art. 1.8 C, 1.8 D
Art. 3.5, 3.6 C
Art. 3.3 B.8
Art. 3.6 B
Sec. 2.1.7.7.2, 3.3.3.4 (c),8.3.3.4(b)
Sec. 1.16.4.3, 1.17.1
Art. 1.5
Art. 2.1, 2.6 A
Art. 3.3 B
Art. 2.4 B, 2.4 H
Art. 3.4, 3.6 A
Art. 3.6 B
Art. 2.1 C
Art. 3.2 D, 3.2 F
Art. 2.4, 3.4
Art. 3.2 E, 3.4, 3.6 A
Art. 2.6 B, 2.4 G.1.b
Art. 3.3 B
(a)
Sec. 1.16
Sec. 1.16
Art. 1.4 B.2.a.3, 1.4 B.2.b.3,1.4 B.2.c.3, 1.4 B.3, 1.4 B.4
Verification of f ' and f ' in accordance with Specification Article 1.4 B prior to construction, except wherespecifically exempted by this Code
-
-
2. Inspection of welding:
m ACC
b. Manufacturer's certified test reports.
a. Identification markings to conform to ASTM standards specifiedin the approved construction documents.
2) Reinforcing steel resisting flexural and axial forces inintermediateand special moment frames, and boundary elements of specialstructural walls of concrete and shear reinforcement.
a. Cold-formed steel deck:
1) Floor and roof deck welds.
b. Reinforcing steel:
1) Verification of weldability of reinforcing steel other thanASTM A 706.
4) Other reinforcing steel.
3) Shear reinforcement.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:09:1
7 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
Author09.09.2016
16073
GENERAL
STRUCTURAL
NOTES
S103
09.09.2016PERMIT SET
# Date Revision
SW-1
SW-1
SW-1
SW-1
FOOTING AND FOUNDATIONPLAN NOTES:
MARKS AND SYMBOLS LEGEND
FTG DESIGNATIONTOF EL, SEE DET ON (S501) FOR REQDFROST DEPTH
FTG EL
1. COORDINATE LOCATION OF DEPRESSED SLABS, SLOPEDSLABS, AND FLOOR DRAINS WITH ARCHITECTURAL ANDMECHANICAL DRAWINGS.
2. SEE ARCHITECTURAL DRAWINGS AND CIVIL DRAWINGS FOREXTERIOR CONCRETE WORK AT DOORS, SIDEWALKS, ETC.
3. CENTER ALL SPOT FOOTINGS UNDER COLUMNS AS SHOWNON PLAN, TYPICAL UNO.
4. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS TO ALLSTEEL COLUMNS.
5. SEE FOOTING AND FOUNDATION DETAILS ON SHEET (S501)FOR BURIED PIPES RUNNING PARALLEL AND PERPENDICULARTO FOOTINGS.
6. SEE FOOTING AND FOUNDATION DETAILS ON SHEET (S501)FOR TYPICAL CONSTRUCTION AND CONTROL JOINTS INFLOOR SLABS.
7. SEE FOOTING AND FOUNDATION DETAILS ON SHEET (S501) FORLOCATIONS WHERE CONTROL JOINTS ARE DISCONTINUOUS.
8. SEE FOOTING AND FOUNDATION DETAILS ON SHEET (S501)FOR FILL BENEATH FOOTINGS
9. SEE FOOTING AND FOUNDATION DETAILS ON SHEET (S501)FOR REINFORCING AROUND MISCELLANEOUS OPENINGS INMASONRY WALLS.
10. SEE FOOTING AND FOUNDATION DETAILS ON SHEET (S501)FOR REINFORCING AROUND RECESSES IN MASONRY WALLS.
11. SEE FOOTING AND FOUNDATION DETAILS ON SHEET (S501)FOR MASONRY CONTROL JOINTS.
12. SEE FOOTING AND FOUNDATION DETAILS ON SHEET (S501)FOR TERMINATION ON HORIZONTAL WALL REINFORCING ATENDS OF WALLS.
13. SEE MASONRY LINTEL SCHEDULE (S301) FOR JAMB COLUMNSAT SIDES OF OPENINGS.
DEPRESSED FND WALL,POUR SLAB OVER, SEE FTG ANDFND DETS ON (S501)
FTG STEP, SEE FTG ANDFND DETS ON (S501)
FLR OFFSET, SEE FTG ANDFND DETS ON (S501)
CONC WALL, SEE SCHED ON (S301)
S S
CONC WALL, SEE SCHED ON (S301)CW-X
CONC WALL BLW AND MAS WALL ABV,SEE SCHED ON (S301)
MW-X
CW-X
FC-x CONT FTG, SEE SCHED ON (S301)
FS-x SPOT FTG, SEE SCHED ON (S301)
CJ CONTROL JOINT, SEE FTG AND FND DETS ON (S501)
FD FLR DRAIN, SEE ARCH FOR EXACT LOCATION
SECTION MARKSHEET NUMBER
DEPRESSED SLAB, SEE ARCH PLANS FOREXACT LOCATION AND EL
MAS WALL, SEE SCHED ON (S301)
STL COL
MAS WALL, SEE SCHED ON (S301)MW-X
HELICAL PIER, BY SUPPLIER/MFRSEE SCHED ON (S302)
SW-x WOOD SHEAR WALL, SEE SCHED ON (S510)
(E)FC2.0 102'-2"
(E)FS6.0 102'-2"
(E)FC2.0 101'-2"
(E)FS6.0 102'-2"
(E)FC2.0 100'-0"
(E)FC2.0 99'-4"
(E)FC5.0 100'-0"
(E)FC3.0 101'-2"
(E)FC5.0 101'-2"
(E)FC2.0 102'-2"
(E)FC2.0 101'-2"
(E)FC2.0 100'-0"
(E)FC2.0 100'-0"
(E)FC2.0 100'-0"
(E)FC1.0 97'-0"
(E)FC1.0 97'-0"
(E)FC3.0 100'-0"
(E)FC3.0 100'-0"
(E)FC3.0 100'-0"
(E)FC3.0 #6 114'-7"
(E)FC2.0 114'-7"
(E)F
C3.
0 #6
113'
-10"
(E)F
C3.
0 #6
112'
-2"
(E)F
C3.
0 #6
110'
-5"
(E)F
C3.
0 #6
108'
-10"
(E)F
C3.
0 #6
107'
-3"
(E)F
C3.
0 #6
105'
-8"
(E)F
C3.
0 #6
104'
-4"
(E)F
C3.
0 #6
103'
-1"
(E)F
C3.
0 #6
101'
-2"
(E)F
C3.
0 #6
113'
-10"
(E)F
C3.
0 #6
112'
-2"
(E)F
C3.
0 #6
110'
-5"
(E)F
C3.
0 #6
108'
-10"
(E)F
C3.
0 #6
105'
-8"
(E)F
C3.
0 #6
104'
-4"
(E)F
C3.
0 #6
103'
-1"
(E)F
C3.
0 #6
102'
-1"
(E)F
C3.
0 #6
107'
-3"
(E)FC3.0 #6 101'-2"
(E)F
C3.
0 #6
101'
-2"
FC4.
511
4'-7
"
FC2.
011
4'-7
"
FC3.0 114'-7"
FC3.0 114'-7"
CW
-08A
CW-08
CW-08
CW
-08
STUD WALLS2x6 AT 16"oc
4" UNREINFORCEDCONC SLAB OVER 4" OFGRAVELT/ SLAB = 116'-1"
4" UNREINFORCEDCONC SLAB OVER 4" OFGRAVELT/ SLAB = 116'-1"
4" UNREINFORCEDCONC SLAB OVER 4" OFGRAVELT/ SLAB = 117'-10"
HSS20X20X3/4
HSS20X20
X3/4
HSS4X4X
1/4
HSS4X4X
1/4
HSS4X4X
1/4
HSS20X20
X3/4
HSS12X12
X1/2
HSS12X12
X1/2
FC3.0 100'-0"
FC3.0 102'-0"
FC3.
010
2'-0
"
FC2.0 100'-0"
FC2.0 100'-0"
FS4.0 100'-0"
1
1
2
2
3
3
4
4
AA
CC
DD
BB
EE
FF
GG
HH
5
5
6
6
7
7
8
8
6.2
6.2
HSS4X4X1/4
FC3.0 102'-0"
CW
-08A
CW-08A
MW
-06
D1
S502
D2
S502
TYP AT EXT, UNO
MW-08
D2
S502
D2
S502
D3
S502
CW
-08A
MW
-06
CW-14
MW-06
CW
-08
MW
-08
CW
-08A
MW
-06
CW-06
MW-06
CW-08
MW-08
FC3.
010
0'-0
"
CW-08
MW-08
FC3.0 100'-0"
CW-14
MW-06
FC3.
010
0'-0
"
C2
S502
C2
S502
C2
S502
C2
S502
D3
S502
C1
S502
A1
S502
FC3.
010
0'-0
"
MW-06
CW-06
CW-12
TYP AT EXT, UNO
FC3.0 100'-0"
TYP AT INT, UNO
FC2.0 100'-0"
CW-08
MW-08
FC3.0 100'-0"
CW-08ATYP AT LOADINGDOCK
TYP AT LOADINGDOCK
D2
S502
FC3.0 100'-0"
CW-08A
MW-08
FC3.0 100'-0"
A4
S510 TYP
A3
S510 TYP
D2
S502
D2
S502
1'-0"2'-0"
2'-0"2'-0"
2'-0"
1'-0"
1'-6" 1'-6"
1'-0"
3'-0"3'-0"
1'-0"
1'-0"
6'-0"
1'-0"
A4
S501TYP (4)LOC
C1
S502CW-08A
1 2 3 4
56
78
9 101112
13
1415
16
17
18
1920 21
22
232425 26
2728
24" THICK MAT FOOTINGREINF WITH #7 AT 9" oc EW,TOP AND BOTT. HOOK AT EDGEST/FTG = 102'-0"
24" THICK MAT FOOTINGREINF WITH #7 AT 9" oc EW,TOP AND BOTT. HOOK AT EDGEST/FTG = 103'-2"
24" THICK MAT FOOTINGREINF WITH #6 AT 9" oc EW,TOP AND BOTT. HOOK AT EDGEST/FTG = 103'-2"
24" THICK MAT FOOTINGREINF WITH #7 AT 9" oc EW,TOP AND BOTT. HOOK AT EDGEST/FTG = 103'-2"
24" THICK MAT FOOTINGREINF WITH #7 AT 9" oc EW,TOP AND BOTT. HOOK AT EDGEST/FTG = 103'-2"
TYP (6)LOC
CW-08A
FC3.0 100'-0"
CW-08A
FC3.0 100'-0"
HSS6X6X
1/4
C1
S502
CW-08
TYP AT INT, UNO
FC2.0 114'-7"
CW-08
TYP AT (2) PIER CAP
CUT OPENING IN (E)MAS WALL FOR NEW3'-0" DOOR, SEE DET
TYP5"
FC3.0 100'-0"
4" THICK SOG REINF W/ #3 AT 24"ocEW OVER 4" GRANULAR FILL OVERPREPAIRED SUBGRADE.T/SLAB = 104'-0", VERIFY W/ ARCH
HSS10X6X
1/2
HSS10X6X
1/2
B2
S502CUT NEW OPENING IN WALL
FC2.0 100'-0"
MW-06
CUT OPENING IN (E) MAS WALL,NEW 3'-0" DOOR, SEE DET
INFILL (E) OPENING W/FLUTED MAS TO MATCH (E)SEE DET /(B1 S502)
1'-0"
3'-6"
3'-6"
CUT OPENING IN (E)MAS WALL FOR NEW6'-0" DOOR, SEE DET
TYP AT (7) PIER CAP
TYP AT (5) PIER CAP
3" MIN TOPPING SLAB REINF W/6"X6"-W1.4/W1.4 WWF. SEEARCH FOR ELEV. PATCH FLOORSLAB AS REQUIRED AFTERINSTALLATION OF NEWFOUNDATIONS
3" MIN TOPPING SLAB REINFW/ 6"X6"-W1.4/W1.4 WWF.SEE ARCH FOR ELEV
3" MIN TOPPING SLAB REINFW/ 6"X6"-W1.4/W1.4 WWF.SEE ARCH FOR ELEV. PATCHFLOOR SLAB AS REQUIREDAFTER INSTALLATION OF NEWFOUNDATIONS.
/(C5 S702)
/(C5 S702)
4" THICK SOG REINF W/ #3 AT 24"ocEW OVER 4" GRANULAR FILL OVERPREPAIRED SUBGRADE.T/SLAB = 102'-1" VERIFY W/ ARCH
REMOVE (E) FOUNDATION ASREQUIRED FOR INSTALLATIONOF NEW WALL
SIZE MAS LINTEL TO SPAN FULLOPENING W/OUT 6" CMU COLS
B2
S502 SIM
EXTENT OFBASEPL BYND, TYP
B4
S502
B6
S502
A2
S502
EXTENT OFBASEPL BYND, TYP
A3
S502
HSS20X20
X3/4
A3
S502
A3
S502
A3
S502
(E) CONC SEATING STEPSTO REMAIN, SEE ARCH
REBUILT CONC STEPS, SEEARCH FOR INFORMATION
1'-1
0"
A5
S502
B4
S501(2) PLCS
SITE WALL, SEEARCH FOR EXTENT
FC2.0 100'-0"FC2.0 102'-0"
REMODEL / ADDITIONPLAN NOTES
1. THE EXISTING INFORMATION SHOWN IS TO BE FIELDVERIFIED. IT SHOULD BE ANTICIPATED THAT ADJUSTMENTSWILL BE NECESSARY.
2. INFORMATION FOR DIMENSIONS IS CONTAINED IN ASEPARATE SET OF ARCHITECTURAL PLANS.
3. THE CONTRACTOR SHALL VERIFY THESE DRAWINGS WITHEXISTING CONDITIONS AND NOTIFY THEARCHITECT/ENGINEER IMMEDIATELY OF INCONSISTENCIESBETWEEN THE DRAWINGS AND ACTUAL CONDITIONS BEFOREPROCEEDING WITH DEMOLITION OR CONSTRUCTION.
4. THE CONTRACTOR SHALL ALSO NOTIFY THE OWNERIMMEDIATELY IF ANY WORK INDICATED IN THE CONTRACTDOCUMENTS CANNOT BE PERFORMED DUE TO EXISTINGFIELD CONDITIONS.
5. IF ANY EXISTING FIRE PROOFING OR FIRE ASSEMBLIES AREDAMAGED DURING DEMOLITION OR CONSTRUCTION, THEYSHALL BE REPAIRED TO CONFORM TO ORIGINAL FIRERATING.
6. REMOVE EXISTING CONSTRUCTION AS INDICATED IN THEARCHITECTURAL DEMO DRAWINGS AND WHERE NOTED INSTRUCTURAL DETAILS.
7. THE CONTRACTOR SHALL NOT CUT STRUCTURAL WORK IN AMANNER RESULTING IN A REDUCTION OF LOAD CARRYINGCAPACITY OR LOAD/DEFLECTION RATIO. THE CONTRACTORSHALL NOTIFY THE ENGINEER OF ALL STRUCTURAL CUTSPRIOR TO EXECUTION SO THAT APPROVAL CAN BEOBTAINED.
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:09:2
0 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
Author09.09.2016
16073
FOOTING
AND
FOUNDATION
PLAN
S201
09.09.2016PERMIT SET
NORTH
S201 SCALE: 1/8" = 1'-0"
A1 FOOTING AND FOUNDATION PLAN
# Date Revision
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
ROOF FRAMING PLAN NOTES: MARKS AND SYMBOLS LEGEND1. VERIFY ROOF SLOPES, DRAINS, AND DECK BEARING
ELEVATIONS WITH ARCHITECTURAL DRAWINGS. SEE ROOFFRAMING DETAILS ON SHEET (S701).
2. ALL JOISTS SHALL HAVE 5" DEEP BEARING ENDS. UNO.3. ALL ROOF OPENINGS SHALL BE FRAMED AS INDICATED IN
ROOF FRAMING DETAILS ON SHEET (S701).4. SEE ROOF FRAMING DETAILS ON SHEET (S701) FOR
CONCENTRATED LOADS LOCATED FURTHER THAN 6" FROMJOIST PANEL JOINT.
5. SEE ROOF FRAMING DETAILS ON SHEET (S701) FORMECHANICAL UNITS HUNG BELOW JOISTS.
6. VERIFY SIZE, WEIGHT, AND LOCATION OF ALL ROOF TOPMECHANICAL UNITS WITH ARCHITECTURAL AND MECHANICALDRAWINGS. SEE ROOF FRAMING DETAILS ON SHEET (S701)FOR STEEL FRAMES AT ALL ROOF TOP EQUIPMENT.COORDINATE OPENINGS WITH MECHANICAL, ELECTRICAL,AND GENERAL CONTRACTORS.
7. OPEN WEB STEEL JOISTS AND JOIST GIRDERS SHALL BEDESIGNATED BY THE MANUFACTURER TO SUPPORT THEMECHANICAL AND LATERAL LOADS SHOWN ON THE ROOFFRAMING PLANS IN ADDITION TO THE UNIFORM AND POINTLOADS SHOWN.
8. WHERE SKYLIGHTS OR MECHANICAL UNITS INTERRUPTHORIZONTAL BRIDGING, PROVIDE CROSS BRIDGING AT JOISTSPACES ON EA SIDE, TYPICAL.
9. WHERE DIAGONAL BRIDGING CONFLICTS WITH MECHANICALDUCTS, REMOVE DIAGONAL BRIDGING AND REPLACE WITHHORIZONTAL BRIDGING (AFTER ROOF DECK IS IN PLACE).
10. * - INDICATES THAT THESE JOISTS SHALL BE DESIGNED FORAN ADLOAD OF 1000# AT ANY TOP CHORD PANEL POINT. THISLOAD IS TO BE ADDED TO THE GIRDER TOP CHORD LOAD.MULTIPLE "*" ARE ADDITIVE.
11. JOIST DESIGNER SHALL DESIGN JOISTS AND SUPPLYADDITIONAL BRIDGING AS REQUIRED FOR 13 PSF NET UPLIFTDUE TO WIND. THERE IS NO UPLIFT ON GIRDERS.
12. SEE ROOF FRAMING DETAILS ON SHEET (S701). FORREINFORCING AROUND MISCELLANEOUS MASONRYOPENINGS SEE DETAILS ON SHEET (S501).
13. SEE FOOTING AND FOUNDATION DETAILS ON SHEET (S501)FOR MASONRY CONTROL JOINTS.
14. SEE FOOTING AND FOUNDATION DETAILS ON SHEET (S501)FOR TERMINATION OF HORIZONTAL REINFORCING AT ENDSOF MASONRY WALLS.
15. SEE ARCHITECTURAL PLANS FOR ALL STEEL COLUMNLOCATIONS (DIMENSIONS).
16. SPRINKLER DESIGNER SHALL COORDINATE THE SPRINKLERDESIGN WITH THE JOIST/GIRDER SHOP DRAWINGS.
17. MASONRY LINTEL DEPTH BASED ON ROUGH OPENING WIDTH.SEE MASONRY LINTEL SCHEDULE (S301) FOR REINFORCINGAND JAMB COLUMNS AT SIDES OF OPENINGS.
MTL ROOF DECK
RD ROOF DRAIN, SEE ARCH AND MECH FOR EXACT LOCATION
HORIZ BRDG REQD FOR UPLIFT, SEE STLJST SUPPLIER FOR REQUIREMENTS
D-x
UNIFORM ROOF SNOW LOAD, SEE GSN
MAX PSF
O PSF
D-1 MAX = 65 PSFL =13'-3"
D-2 MAX = 68 PSFL =13'-9"
'L'
SNOW DRIFT LOADING DIAGRAM
WOOD WALL ABV, SEE SCHED ON (S510)
SECTION MARKSHEET NUMBER
MAS WALL, SEE SCHED ON (S301)
STL COL
T=C=xK ROOF JST TOP CHORD SHALL BE DESIGNED FOR AN ADDITIONAL LOAD OF __KIPS IN TENSION AND COMPRESSION. LOADS ARE PROVIDED AT ULTIMATE STRENGTH LEVEL
DOUBLE SHEAR CONNECTION, SEE SCHED ON(S302)
2x8
AT 1
6"oc
(3)2
x10
ROOF SHEATHING:19/32" OSB W/ 40/20 SPANRATING 8d AT 6"ocEDGES, AND 12"oc FIELD
W36X170 MFB
W12X14
W12
X14
W12
X14
W12
X14
W12X14
W12X14
W12X14
W12X14
W12X14
W12X14
W12X14
W12
X14
W12
X14
W12X14
W12
X14
W36
X170
W36X170
W30
X90
W12X14
W12X14
W12X14
W36X135
W12X14
W12X14
W12X14
W36X170 MFB W36X170
W36X170
W18
X35
W21X44
W12X14W12X14
W21X44 W21X44
W16X31
W14X22 W14X22
W16X31 MFBW16X31
1
1
2
2
3
3
4
4AA
CC
DD
BB
EE
FF
GG
HH
5
5
6
6
7
7
8
8
6.2
6.2
W36
X135
MFB
W18
X40
W18
X40
W8X10
W18X35
W30
X108
W16
X26
W16
x26
W12x14
W12x14
W12
X14
W12x14
W16
x26
W12x14W12X14
W1 2X1 4
W12X14
W12X14
W12X14
W12X14
W12X14
W12X14
W12X14
W12X14
W12X14
W21X44
W36
X170
W24
X76
W12
X14
W12
X14
B2
S701 TYP
B3
S701 TYP
B3
S701 TYP
C2
S701
C2
S701
C2
S701
C2
S701
B2
S701 TYPD4
S601
TYP AT CATWALKHANGING COLUMN
B2
S701 TYP
B2
S701 TYP
B3
S701 TYP
2x8 BLOCKING AT 16"oc,TYP
A5
S510 TYP
A6
S510 TYP
A5
S510 TYP
A6
S510 TYP
W36
X135
C1
S702
C1
S702
2
W12X14
W12X14
W12
X14
W12
X14
W12
X14
W12
X14
W12
X14
W12
X14
W12
X14
W12
X14
W12
X14
W12X14
W12X14
CANT
CAN
T
W16
X26
SIM
W36
X135
MFB
W36X170
TYP
W12X14
W12X14
53
53
W14X22
W8X10
W8X10
W8X10
W8X10
W8X10
W8X10
W8X10
W12
X19
W12
X14
C12X
20.7
W12X14
W8X10
W16
X26
W14X22
W14X22
18" O
WSJ
(350
/235
+ D
RIF
T)
14" OWSJ (350/235 + DRIFT)
28" OWSJ (350/235 + DRIFT)
(5) E
Q S
PCS
4
AA
CC
DD
BB
EE
FF
GG
HH
5
5
6
6
7
7
8
8
6.2
6.2
EXISTING ROOFFRAMING
EXISTING ROOFFRAMING
HSS6
X6X3
/16
HSS6
X6X3
/16
CANT
HSS6x6x5/16
HSS6X6X3/16
HSS8x6x3/8 BLW,RADIUSED HSS6x6x3/16BLKG ABOVE BTWNOUTLOOKERS
C2
S701
C2
S702 TYPA2
S701 TYP
A2
S701 TYP
A3
S701
D3
S702
D4
S702
A3
S701
D4
S702
D2
S702
D6
S702
B2
S701 TYP
1
1
1
CANOPY ABOVE
D-1
D-2
HSS10X6X1/2
6"
HSS6X6X1/4 (ABV)
CANT
CANT
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4 HSS
6X6X
3/16
HSS6
X6X3
/16
HSS6
X6X3
/16
W10X12
HSS
6X6X
3/16
HSS
6X6X
3/16
HSS8
X6X3
/8 (B
LW)
HSS8X6X3/8 (BLW)
HSS6X6X1/4
HSS6X6X1/4
HSS8X6X3/8 (BLW)
C4
S702
C3
S702
HSS6X6X1/4 (ABV)
HSS6x6x1/4 POSTSBTWN HIGH/LOW BM,TYP (9) LOC
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6x6x3/8, TYP
PROVIDE 1/2" EXPANSIONJOINT AROUND COLUMN ATEXISTING ROOF, TYP
HIGH/LOW
HIGH/LOW
A3
S701SIM
A3
S701SIM
SIM
W8X10
W8X10
A3
S702
CANT
MAS WALL
(6) EQ SPCS
B5
S702
A2
S702
A1
S702
B6
S702
53
53
SIM
B1
S702
OH
B1
S702
LOW
4
4
CC
DD
EE
FF
5
5
6
6
7
7
8
8
6.2
6.2
HSS6X4X1/4
HSS6X4X1/4
HSS6X4X1/4
HSS6X4X1/4
HSS6X4X1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS6
X4X1
/4
HSS6
X4X1
/4
HSS6X4X1/4HSS6X4X1/4
HSS6X4X1/4
HSS6X4X1/4
HSS6X4X3/8
HSS6X4X1/4
HSS6X4X3/8
HSS6X4X1/4
HSS6X4X1/4
HSS6X4X1/4
HSS4X4X1/4
HSS6X4X1/4
HSS4X4X1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS4X4X1/4
HSS4X4X1/4
HSS6X4X1/4 HSS6X4X1/4
HSS4X4X1/4HSS4X4X1/4
HSS6X4X1/4 HSS6X4X1/4
HSS4X4X1/4HSS4X4X1/4
HSS6X4X1/4 HSS6X4X1/4
HSS4X4X1/4HSS4X4X1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS
6X4X
1/4
HSS6X4X1/4
HSS6X4X1/4
HSS6X4X1/4
HSS6X4X1/4
HSS4X4X
3/16
HANGER, TYP
1 1/4"x3/16" GALVGRATING, TYP
D1
S601 TYP
D1
S601 TYP
D2
S601 TYP
D2
S601 TYP
D3
S601 TYP
D3
S601 TYP
D2
S601 TYP
D2
S601 TYP
HSS6X4X1/4
HSS6X4X1/4
HSS4X4X1/4
HSS6X4X1/4
HSS6X4X1/4
HSS6x4x1/4
HSS4X4X1/4
HSS4x4x1/4 BRACEUP, TYP
D5
S601TYP
HSS6x4x1/4
HSS6x4x1/4
OPEN
OPEN
C1
S601
C1
S601
C1
S601
C4
S601TYP ATEAST
C2
S601C2
S601
C3
S601
TYP ATWEST
C2
S601
C1
S601
53
53
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:09:2
2 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
Author09.09.2016
16073
ROOF
FRAMING
PLAN
S202
09.09.2016PERMIT SET
NORTH
S202 SCALE: 1/8" = 1'-0"
B1 UPPER ROOF FRAMING PLANNORTH
S202 SCALE: 1/8" = 1'-0"
B5 LOW ROOF FRAMING PLAN
NORTH
S202 SCALE: 1/8" = 1'-0"
1 CATWALK FRAMING PLAN
# Date Revision
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:09:5
0 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
Author09.09.2016
16073
ROOF 3D
VIEWS
S203
09.09.2016PERMIT SET
NO SCALE:S203
1 3D VIEWNO SCALE:S203
2 3D VIEW
NO SCALE:S203
3 3D VIEWNO SCALE:S203
4 3D VIEW
# Date Revision
ML-1
MASONRY LINTEL NOTES:
1. LINTEL WIDTH AND MATERIAL TYPES SHALL BE THE SAME AS THE WALL IN WHICH THELINTEL IS CONSTRUCTED.
2. GROUT MASONRY LINTELS MONOLITHICALLY WITH THE SUPPORT WALL OR COLUMN AT EAEND.3. MASONRY LINTELS ML-1 THRU ML-4 SHALL BE USED OVER OPENINGS IN MASONRY WALLS
WHEN A SPECIFIC MASONRY LINTEL IS NOT OTHERWISE SPECIFIED. WHEN A LINTEL ISSPECIFIED ON THE PLANS, THE MAXIMUM SPAN AS NOTED IN THIS SCHEDULE SHALL NOTAPPLY. CONSULT THE STRUCTURAL ENGINEER FOR LINTELS NOT SPECIFIED ON THEPLANS WHICH HAVE A SPAN GREATER THAN 10'-0".
4. MASONRY LINTELS ML-1 THRU ML-4 SHALL NOT BE LOCATED DIRECTLY BELOW FLOOR ORROOF BEAMS OR GIRDERS UNLESS NOTED OTHERWISE ON THE PLANS. JOISTS SHALL NOTBEAR ON ANY LINTEL LESS THAN 16" DEEP. CONSULT THE STRUCTURAL ENGINEER FORLINTELS NOT SHOWN ON THE PLANS WHICH ARE LOCATED DIRECTLY BELOW FLOOR ORROOF BEAMS OR GIRDERS.
5. EXTEND ALL HORIZONTAL REINFORCING BEYOND THE EDGE OF ALL OPENINGS. IF HORIZONTALREINFORCING CANNOT EXTEND LAP SPLICE LENGTH BEYOND EDGE OF OPENING, PROVIDE 90°STANDARD HOOK.
6. SPLICE TOP BARS AT MID-SPAN OF LINTEL ONLY AND BOTTOM BARS OVER SUPPORTS ONLY.7. HORIZONTAL WALL REINFORCING SHALL CONTINUE THRU MASONRY LINTELS, WHERE BOTH
HORIZONTAL WALL REINFORCING AND LINTEL REINFORCING OCCUR IN THE SAME COURSE, USETHE LARGER REINFORCING.
8. DOWEL VERTICAL REINFORCING OF WALL ABOVE LINTEL INTO THE FULL DEPTH OF LINTEL.9. SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS.
MASONRY LINTEL SCHEDULE
MARK LINTEL DEPTHHORIZONTAL STIRRUPS
REINFORCINGLINTEL SPAN(MAX)
COMMENTS
NONE(1) #7 BARML-1 8" 3' - 4" MC-1 EA END
ML-2 16" (1) #7BAR CONT T&B #4 AT 8"oc6' - 0" MC-1 EA END
ML-3 24" (1) #7BAR CONT T&B #4 AT 8"oc8' - 0" MC-2 EA END
ML-4 32" (1) #7BAR CONT T&B #4 AT 8"oc10' - 0" MC-3 EA END
8"
ML-2
16"
ML-3
24"
ML-4
32"
MASONRY WALL NOTES:
1. COORDINATE WITH ARCHITECTURAL DRAWINGS, MASONRY WALL FINISHES, TYPES OF MATERIAL, COURSING, ETC.2. DO NOT SOLID GROUT WALLS UNLESS NOTED OTHERWISE.3. ALL MASONRY BELOW GRADE SHALL BE GROUTED SOLID.4. VERTICAL REINFORCING SHALL BE CENTERED IN THE WALL UNLESS NOTED OTHERWISE.5. (1) VERTICAL BARS MINIMUM AT ALL CORNERS AND END OF WALLS.6. HORIZONTAL WALL REINFORCING SHALL BE PLACED BETWEEN VERTICAL MASONRY COLUMN REINFORCING BARS.7. HORIZONTAL WALL REINFORCING SHALL CONTINUE THRU MASONRY LINTELS, WHERE BOTH HORIZONTAL WALL
REINFORCING AND LINTEL REINFORCING OCCUR IN THE SAME COURSE, USE THE LARGER REINFORCING.8. MASONRY WALLS NOT DESIGNATED ON THE PLANS SHALL BE REINFORCED AS FOLLOWS:
9. SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS.10. MASONRY SHALL BE SPECIAL INSPECTED SEE GENERAL STRUCTURAL NOTES.11. HORIZONTAL WALL REINFORCEMENT SPACING SHALL NOT EXCEED 48"oc OR THE WALL LENGTH.
THICKNESS
6"8"
10"12"
VERTICAL REINFORCING
#5 BARS AT 32"oc#5 BARS AT 32"oc#6 BARS AT 32"oc#6 BARS AT 32"oc
HORIZONTAL REINFORCING
#4 BARS AT 48"oc#5 BARS AT 48"oc#6 BARS AT 48"oc
(2) #5 BARS AT 48"oc
MASONRY WALL SCHEDULE
TYPE 'C'(SINGLE HORIZ BARS)
DBL VERT BARS)
TYPE 'B'(DBL MAT REINF)
TYPE 'A'(SINGLE MAT REINF)
HORIZ WALL REINF
HORIZ WALL REINF
HORIZ WALL REINF
VERT WALL REINF
VERT WALL REINF
VERT WALL REINF
2 1/
2"2
1/2"
2 1/
2"2
1/2"
MARK THICKNESSVERTICAL HORIZONTAL
REINFORCINGMATERIALS SOLID
GROUTTYPE JOINT
MW-06 6" CMU (1) #5 AT 32"oc (1) #4 AT 48"oc A NONO
MW-08 8" CMU (1) #5 AT 32"oc (1) #5 AT 48"oc A NONO
TYPE 'D'(DBL HORIZ DBL VERT BARS)
HORIZ WALL REINF
VERT WALL REINF
2 1/
2"2
1/2"
NON-BEARING MASONRY ORCONCRETE WALL BRACING SCHEDULE
NON-BEARING MASONRY OR CONCRETE WALL BRACING NOTES:
1. ALL NON-BEARING WALLS AND PARTITIONS SHALL BE BRACED AT THE TOP.2. NON-BEARING WALLS THAT ARE NOT DIRECTLY CONNECTED TO THE STRUCTURE AT THE TOP SHALL BE BRACED AT A
MINIMUM OF 8'-0"oc.3. NON-BEARING WALLS MAY BE BRACED BY INTERSECTING WALLS IF THE SUPPORTING WALLS ARE EQUAL TO OR
GREATER IN HEIGHT THAN THE WALL WHICH THEY BRACE. THE MINIMUM LENGTH OF THE MASONRY SUPPORT WALLSHALL BE 4'-0". WHERE INTERSECTING WALLS ARE SPACED MORE THAN 8'-0"oc APART, AN ANGLE BRACE IS REQUIRED.
FOR METAL STUDS, SEEGSN
L5x5x1/4 x 6" LONG W/ (2) 5/8"Øx 6" HSA
DIAGONAL STL BRACE, SEESCHED FOR SIZE AND MAXLENGTH, EXTEND BRACE TO TOPOF NEAREST BM OR JST
STL BM OR JST
MAS OR CONC WALL
(1) 3/4"Ø BOLT
1
1 MAX
(1) 5/8"Ø ADHESIVEANCHOR INTO CONCSTRUCTURE
SEE SCHEDULE
L = M
AXIMUM LE
NGTH FOR BRACE SIZEANGLE BRACE SIZE MAXIMUM LENGTH 'L'
L2 1/2X2 1/2X3/16 8'-0"
L3x3x3/16 9'-6"
L3 1/2x3 1/2x1/4 11'-0"
L4x4x1/4 13'-0"
L5x5x5/16 16'-3"
L6x6x5/16 19'-9" 6"
3"
3/16 2"
AT CONTRACTORSOPTION
3/16 2"(3) SIDES
3/16(2) PLCS, TYP
TYPE "A" TYPE "B" TYPE "C" TYPE "D"
EQ EQ
VERT REINF
HORIZREINF
VERT REINF
HORIZREINF
WALL REINFORCEMENT PLACEMENT TYPES:
CONCRETE WALL NOTES:
1. SEE GENERAL STRUCTURAL NOTES FOR COVER AND OTHER REQUIREMENTS NOT NOTED IN SCHEDULE.2. CONCRETE WALLS NOT DESIGNATED ON THE PLANS SHALL BE REINFORCED AS FOLLOWS:
3. PLACE STEEL IN THE CENTER OF THE WALL (EXCEPT TYPE 'B' AND RETAINING WALLS). WALLS THICKER THAN 10" SHALLHAVE TWO CURTAINS OF REINFORCEMENT (PLACED NEAR EA FACE OF THE WALL), UNLESS NOTED OTHERWISE ON THESTRUCTURAL DRAWINGS.
THICKNESS
6"8"
10"12"
VERTICAL REINFORCING
#4 BARS AT 18"oc#4 BARS AT 18"oc#4 BARS AT 16"oc
#4 BARS AT 18"oc EA FACE
HORIZONTAL REINFORCING
#4 BARS AT 16"oc#4 BARS AT 12"oc#5 BARS AT 15"oc
#4 BARS AT 16"oc EA FACE
CONCRETE WALL SCHEDULE
MARK THICKNESSREINFORCING
VERTICALCOMMENTS
HORIZONTAL TOP AND BOTTOMWALL TYPE
CW-08 8" (1) #4 AT 18"oc (1) #4 AT 12"oc (1) #4 A
CW-14 14" (2) #4 AT 16"oc (2) #4 AT 14"oc (2) #4 C __
3" MIN
CW-18 18" (2) #4 AT 16"oc (2) #5 AT 16"oc (2) #5 C __
CW-08A 8" (1) #5 AT 12"oc (1) #4 AT 12"oc (1) #4 B REBAR TOWARDS SOIL SIDE
CW-12 12" (2) #4 AT 16"oc (2) #4 AT 16"oc (2) #4 C __
NOTES:
1. THIS SCHEDULE SHALL BE USED FOR ALL SPLICES, UNLESS NOTED OTHERWISE.2. HORIZONTAL BARS ARE CLASSIFIED AS TOP BARS WHERE 12", OR MORE, OF FRESH CONCRETE IS CAST
BELOW THE REINFORCING BARS.3. CLASS 'B' SPLICES SHALL BE USED FOR ALL SPLICES UNLESS NOTED OTHERWISE.4. TIES AND STIRRUPS SHALL NOT BE SPLICED.5. FOR ALL LIGHTWEIGHT CONCRETE, LAP LENGTHS SHALL BE MULTIPLIED BY 1.3.6. FOR ALL EPOXY COATED BARS, LAP LENGTHS SHALL BE MULTIPLIED BY 1.3 FOR TOP BARS AND 1.5 FOR
REGULAR BARS.7. LAP LENGTHS SHALL BE MULTIPLIED BY 1.25 AT SHEARWALL BOUNDARY ELEMENTS.8. DEVELOPMENT LENGTH 'Ld' IS EQUAL TO CLASS 'A' SPLICE.9. IF REINFORCING HAS CLEAR COVER LESS THAN ONE BAR DIAMETER, LAP LENGTHS SHALL BE MULTIPLIED BY 1.5.10. IF REINFORCING IS NOT ENCLOSED IN TIES OR STIRRUPS AND IS SPACED TIGHTER THAN 3 BAR DIAMETERS ON
CENTER, LAP LENGTHS SHALL BE MULTIPLIED BY 1.5.11. LAP LENGTHS SHALL BE MULTIPLIED BY 1.25 FOR GRADE 75 REBAR.
45° BEND
180° HOOK 135° HOOK(SEISMIC)
OFFSET
D
D
D
D
D4d OR 2 1/2" MIN
D
d
d
12
2
D
d
12d
6d O
R 3" M
IN
90° HOOK
D = 6d FOR #3 - #8D = 8d FOR #9 - #11D = 10d FOR #14 - #18
CONCRETE REINFORCING BAR LAP SPLICE SCHEDULE
REGULAR TOP
CLASS CLASS
A B A B
BARSIZE
f'c = 3000 PSI
#3 17" 22"22" 28"
#4 22" 29"29" 38"
#5 28" 36"36" 47"
#6 33" 43"43" 56"
#7 48" 63"63" 81"
#8 55" 72"72" 93"
#9 62" 81"81" 105"
#10 70" 91"91" 118"
#11 78" 101"101" 131"
REGULAR TOP
CLASS CLASS
A B A B
f'c = 4000 PSI
15" 19"19" 25"
19" 25"25" 33"
24" 31"31" 41"
29" 37"37" 49"
42" 54"54" 71"
48" 62"62" 81"
54" 70"70" 91"
61" 79"79" 102"
67" 87"87" 114"
REGULAR TOP
CLASS CLASS
A B A B
f'c = 4500 PSI
14" 18"18" 23"
18" 24"24" 31"
23" 30"30" 38"
27" 35"35" 46"
40" 51"51" 67"
45" 59"59" 76"
51" 66"66" 86"
57" 74"74" 96"
64" 82"82" 107"
REGULAR TOP
CLASS CLASS
A B A B
f'c = 5000 PSI
13" 17"17" 22"
17" 23"23" 29"
22" 28"28" 36"
26" 34"34" 49"
38" 49"49" 63"
43" 56"56" 72"
48" 63"63" 81"
54" 71"71" 92"
60" 78"78" 102"
REGULAR TOP
CLASS CLASS
A B A B
f'c = 3500 PSI
16" 21"21" 26"
21" 27"27" 36"
26" 34"34" 44"
31" 40"40" 52"
45" 59"59" 75"
51" 67"67" 82"
58" 75"75" 98"
65" 85"85" 110"
73" 94"94" 122"
#3
BAR SIZE
9"
f'c = 3000 PSI
8"
f'c = 4000 PSI
7"
f'c = 4500 PSI
7"
f'c = 5000 PSI
6"
f'c = 6000 PSI
#4
#5
#6
#7
#8
#9
#10
#11
11" 10" 9" 9" 8"
14" 12" 12" 11" 10"
17" 15" 14" 13" 12"
20" 17" 16" 15" 14"
22" 19" 18" 17" 16"
25" 22" 21" 20" 18"
28" 25" 23" 22" 20"
31" 27" 26" 24" 22"
HOOKED BAR DEVELOPMENT LENGTHS, Ldh
NOTES:
1. FOR GRADE 75 REBAR, MULTIPLY LENGTHS BY 1.25.2. FOR LIGHTWEIGHT CONCRETE, MULTIPLY LENGTHS BY 1.3.3. FOR EPOXY COATED REINFORCEMENT, MULTIPLY LENGTHS BY 1.2.4. FOR HOOKS WITH 2.5" MINIMUM SIDE COVER PERPENDICULAR TO PLANE OF
HOOK, MULTIPLY LENGTHS BY 0.7.5. FOR LATERAL LOAD RESISTING ELEMENTS, CRITICAL SECTIONS SHALL BE TAKEN AS THE FACE OF TIE / HOOP AT CONFINED CORES OF COLUMN JOINTS OR SHEAR WALL BOUNDARY ZONE.
TYPICAL SECTION SECTION AT LATERAL LOADRESISTING ELEMENT
2" MIN
2" MIN Ldh
FACE OF CONC
STANDARDHOOK
CRITICALSECTION
Ldh
CRITICALSECTION
FACE OF CONC
STANDARDHOOK
LATERAL LOADRESISTINGELEMENT
TYPICAL FOOTING SECTION
TYP FTG REINF
3" C
LR
3" CLR 3" CLREQ EQ EQ
CONCRETE FOOTING NOTES:
1. PLACE ALL FOOTING REINFORCING IN BOTTOM OF FOOTING WITH 3" CLEAR CONCRETE COVER, UNLESS NOTED OTHERWISE.2. TOP REINFORCING, WHERE SPECIFIED, SHALL BE PLACED IN THE TOP OF THE FOOTING WITH 2" MINIMUM CONCRETE COVER.3. IF FOOTINGS ARE EARTH FORMED, FOOTING WIDTH AND LENGTH SHALL BE 6" WIDER AND LONGER THAN SCHEDULED.4. SEE GENERAL STRUCTURAL NOTES FOR ALL OTHER REQUIREMENTS.5. NOT ALL FOOTINGS ARE USED, SEE FOUNDATION PLAN FOR FOOTING MARKS.6. RUN CONTINUOUS BARS IN 'FC' FOOTING THROUGH INTERSECTED 'FS' FOOTINGS.7. EXTEND CONTINUOUS FOOTINGS 1'-0" BEYOND END OF WALL, EXCEPT AT INTERSECTING CORNERS OR UNO ON PLAN.8. FOOTINGS MAY BE THICKER THAN THE SCHEDULED DEPTH IN AREAS SURROUNDING ANCHOR BOLTS OR HOLD DOWNS, SEE
ANCHORAGE AND HOLD DOWN DETAILS.
C4500-S1500
FS3.0 3' - 0" 3 #5 2' - 6" EQ 2' - 6"#53 '-0" 12" EQ3
CONCRETE FOOTING SCHEDULE
CONT CONTFC2.0 2' - 0" 12" 3 #4 EQ
CONT CONTFC2.5 2'-6"' #5 2' - 0" 14"12" 3 #5 EQ
MARK WIDTHNO SPACING
REINFORCING CROSSWISECOMMENTSLENGTH
SIZE LENGTH NO SPACING
REINFORCING LENGTHWISE
SIZE LENGTHDEPTH
CONT CONTFC1.5 1'-6"' 12" 2 #4 EQ
CONT CONTFC3.0 3' - 0" #5 2' - 6" 14"12" 3 #5 EQ
CONT CONTFTS1.5 1' - 6" 12" 2 #4 EQ
CONT CONTFTS2.0 2' - 0" 12" 3 #4 EQ
FS3.5 3' - 6" 3 #5 3' - 0" EQ 3' - 0"#53 '-6" 12" EQ3
FS4.0 4' - 0" 4 #5 3' - 6" EQ 3' - 6"#54 '-0" 12" EQ4
FS4.5 4' - 6" 4 #5 4' - 0" EQ 4' - 0"#54 '-6" 12" EQ4
FS5.0 5' - 0" 5 #5 4' - 6" EQ 4' - 6"#55 '-0" 12" EQ5
FS5.5 5' - 6" 5 #5 5' - 0" EQ 5' - 0"#55 '-6" 12" EQ5
FS6.0 6' - 0" 6 #5 5' - 6" EQ 5' - 6"#56 '-0" 12" EQ6
CONT CONTFC4.5 4' - 6" #5 4' - 0" 14"12" 4 #5 EQ
CONFIGURATION FOR MAS COL
4" TYP
TIES
VERT COL REINF
TIE,
TYP
2" C
LR T
O
MASONRY COLUMN NOTES:
1. HORIZONTAL WALL REINFORCEMENT SHALL BE LOCATED TO THE INSIDE OF VERTICAL BARS. THECENTERLINE OF VERTICAL BARS SHALL BE LOCATED 2 1/2" FROM FACE OF THE MASONRY.
2. UNLESS NOTED OTHERWISE, VERTICAL REINFORCING AND TIES SHALL EXTEND TO FULL WALL HEIGHT.3. VERTICAL MASONRY COLUMN REINFORCING SHALL EXTEND INTO FOOTING AND TERMINATE WITH A
STANDARD 90° HOOK. FOR CONCRETE FOUNDATION WALLS OVER 5'-0" TALL, VERTICAL COLUMNREINFORCING SHALL DOWEL 4'-0" MINIMUM INTO THE FOUNDATION WALL.
4. IN CONCRETE FOUNDATION WALLS, VERTICAL MASONRY COLUMN REINFORCING SHALL BE TIED WITH #3TIES AT THE SAME SPACING AND CONFIGURATION AS MASONRY COLUMNS ABOVE.
5. SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS.6. SPACE TIES AT 48"oc FROM A POINT 24" ABOVE OPENINGS TO THE TOP OF THE WALL.7. THIS SCHEDULE APPLIES AT AT 6" MASONRY WALL. REDUCE TIES AS REQUIRED TO FIT WITHIN WALL.
RUN HORIZ REINF THRU COL
TYPE 1
TYPE 2
TYPE 3
TYPE 4
TYPE 5
MARK COLUMN SIZEVERTICAL TIES
REINFORCING
TYPE
MC-1 8" x 16" (4) #5 #2 AT 8"oc 1
MASONRY COLUMN SCHEDULE
MC-2 8" x 24" (6) #5 #2 AT 8"oc 2
MC-3 8" x 32" (8) #5 #2 AT 8"oc 3
MC-4 8" x 40" (10) #5 #2 AT 8"oc 4
MC-5 8" x 48" (12) #5 #2 AT 8"oc 5
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:09:5
0 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
Author09.09.2016
16073
SCHEDULES
S301
09.09.2016PERMIT SET
NO SCALE:S301
A1 MASONRY LINTEL SCHEDULE
NO SCALE:S301
C1 MASONRY WALL SCHEDULENO SCALE:S301
C3 NON-BEARING MASONRY OR CONCRETE WALL BRACING SCHEDULENO SCALE:S301
C5 CONCRETE WALL SCHEDULE
NO SCALE:S301
D2CONCRETE REINFORCING BAR LAP SCHEDULES ANDDIAGRAMS
NO SCALE:S301
D1 CONCRETE FOOTING SCHEDULE
# Date Revision
NO SCALE:S301
A3 MASONRY COLUMN SCHEDULE
BEAM TO PARALLEL BEAM WEB PLATE CONNECTION SHEAR CONNECTOR PLATES AT SKEWED MEMBERS TO WIDEFLANGE SECTIONS
BEAM TO BEAM WEB PLATE CONNECTION
BOLT SPACING ANDEDGE DIST, TYP
STL BM
STL BM
WEB PL
STL BM
STL BM
WEB PL
CONDITION A FORSKEWS UP TO 30
DEGREES
CONDITION BFOR SKEWS OVER 30
TO 45 DEGREES
CONDITION CFOR SKEWS OVER 45
TO 60 DEGREES
BACKING BAR(BEVEL)
BACKING BAR(BEVEL)
CLIP ANGLES: L5x3 1/2. THICKNESS SHALL BE EQUAL TO ONE HALF THE BEAM WEBTHICKNESS PLUS 1/16" (1/4" MIN). FOR TWO ROWS OF BOLTS OR SKEWED CONNECTIONS,USE BENT PLATES. WHERE COLUMN WIDTH IS SMALLER THAN THE CONNECTING CLIPANGLES, ANGLE LEGS SHALL BE REDUCED TO MATCH WIDTH OF COLUMN.
BEAM WEB CONNECTION PLATES. THICKNESS EQUALS THE BEAM WEB THICKNESS PLUS1/8" (3/8" MIN).
FILLET WELDS SHALL BE AS FOLLOWS:ONE SIDE: PLATE THICKNESS MINUS 1/16" (1/4" MINIMUM)TWO SIDES: 1/2 PLATE THICKNESS PLUS 1/16"
(1/4" MINIMUM) EA SIDE.
THICKNESS EQUALS BEAM FLANGE THICKNESS OF BEAM FRAMING INTO COLUMN WEB(3/8" MINIMUM).
BOLT EDGE DISTANCE SHALL BE 1 1/2" MINIMUM AT ALL EDGES. BOLT SPACING SHALL BEAT 3". BOLT SPACING MAY BE REDUCED TO 3x THE BOLT DIAMETER IF IT IS REQUIREDFOR A SINGLE ROW OF BOLTS. A SINGLE ROW OF BOLTS IS PREFERRED.
WHEN MORE THAN ONE COLUMN OF BOLTS IS NEEDED, THE FIRST COLUMN SHALL BECOMPLETE WITH THE REMAINDER OF THE BOLTS PLACED IN THE SECOND COLUMN.
A-325 BOLT SCHEDULE
2
5
CLEA
RANC
ES
MIN
TO
PROV
IDE
5
1/4"
5
3/16"
.
2
2
3
3
3 1/2" MIN
1/2" GAP MAX
COPE BM ASREQD
3 1/2" MAX
6
BOLT SPACING ANDEDGE DIST, TYP
5
5
BEAM TO HSS CLIP ANGLE CONNECTION
STL COL
BOLT SPACING
5
COPE AS REQDSTL BM
3CLIP ANGLES NEARSIDE AND FAR SIDE
1
CLIP ANGLES NEARSIDE AND FAR SIDE
1
3 3
MAXIMUM BEAM SIZE IN EACH BEAMDEPTH GROUP No. PER BEAM SIZE
A-325N BOLTS
W8 2 7/8"Ø
W10 2 7/8"Ø
W12 3 7/8"Ø
W14 3 7/8"Ø
W16 4 7/8"Ø
W18 5 7/8"Ø
W21 6 7/8"Ø
W24 6 7/8"Ø
W27 7 7/8"Ø
W30 8 7/8"Ø
W33 9 7/8"Ø
W36 10 7/8"Ø
W40 11 7/8"Ø
W44 12 7/8"Ø
3" TYP
5"
3
SHEAR CONNECTION PLATESAT SKEWED MEMBERS TO HSS
3
5
3"
5 MIN TO PROVIDECLEARANCE
BM WEB
HSS WALL
BENT WEBPL 2
TYP, EA ANGLE2xTYP
(3) SIDES
(3) SIDES, TYP
TYP
CLEARANCES
MIN TO PROVID
E
CLEARANCES
MIN TO PROVIDE1
2
3
4
5
6
HELICAL PIER LOAD SCHEDULE
1. LOADS SHOWN ARE ACTUAL ALLOWABLE LOADS. THE HELICAL PIERDESIGNER SHALL APPLY APPROPRIATE SAFETY FACTORS FOR PIERDESIGN.
2. CONTRACTOR TO COORDINATE NEED FOR ADDITIONAL HELICAL PIERS, IFREQD W/ EOR PRIOR TO GRADE BM REBAR FABRICATION.
3. HELICAL PIER TYPES 2 AND 3 SHALL BE INSTALLED AT A 1V:1H SLOPEPARALLEL TO THE GRADE BEAM AND IN LINE WITH THE MOMENT FRAMECOLUMNS TO A DEPTH TO ACHIEVE LOAD SPECIFIED IN THE SCHEDULE.TERMINATE THE TOP OF THE HELICAL PIER NINE INCHES INTO THE GRADEBEAM WITH AN END EFFECTER CAP THAT CAN ACHIEVE THE LATERALLOAD IN TENSION OR COMPRESSION WITH THE APPROPRIATE SAFETYFACTORS.
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:09:5
1 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
Author09.09.2016
16073
SCHEDULES
S302
09.09.2016PERMIT SET
NO SCALE:S302
D1TYPICAL BOLTED WEB PLATE CONNECTIONS WITH BOLTSCHEDULE (SINGLE SHEAR)
NO SCALE:S302
D5 DETAIL
# Date Revision
A A
b + 2d MIN
24" M
IN
d (V
ARIE
S)
CONC FTG
STRUCT FILLSEE GSN
CONSULT THE PROJECT SPECIFICATIONSAND SOILS REPORT FOR EARTHWORKREQUIREMENTS. IN ABSENCE OFINFORMATION, REFER TO THE DTL ABV
b
2
1 BOTT OF TRENCH TO BE ABVTHIS LINE
BACKFILL TRENCHPER GSN
CONC FTG
CONC WALL
PIPE
6"
IF THIS DIMEXCEEDS 1'-6", DONOT THICKEN FTG
PIPE BELOW FOOTING
6" M
IN
PIPE THROUGH FOOTING
THICKEN FTG
THICKENED FTG
LAP SPLICE
PROVIDE ADDITIONALLENGTHWISE REINFAS SHOWN TO MATCHBAR THAT IS CUT
PROVIDE SLEEVE FORALL PIPES PASSINGTHRU WALLS AND FTGS
CONC FTGPROVIDE SLEEVE FORALL PIPES PASSINGTHRU WALLS AND FTGS
1/2" CLEAR
12" MIN 3d 12" MIN
"d" = LARGEST PIPE DIAMETER
1/2" CLEAR
3d
"d" = LARGEST PIPE DIAMETER
12" MIN 12" MIN
CLR3"
8" M
IN
0" T
O 1
'-6"
VAR
IES
DOWELS TO MATCHVERT WALL REINF
'Z' BARS TO MATCHCONT FTG REINF 2x4 BEVELED KEYWAY,
CONT
CONC FND WALL
4'-0
" MAX
H
1.5 H MIN
W
CONC FTG
PROVIDE TRANSVERSEREINF IN VERT FTG TOMATCH FTG TRANSVERSEREINF
EQ
EQ
(2) #5 x 4'-0" ATEA STEP, TYP
"T" T
YP
"T" TYP"T" = FTGTHICKNESS
ADDITIONAL VERTBARS AT CORNERTYP
CORNER BARS TOMATCH WALL HORIZBARS
CONC WALL
CORNER BARS TO MATCHWALL HORIZ BARS
CONC WALL
ADDITIONAL VERT BARSAT INTERSECTIONTYP
LAP LENGTH, TYP
LAP
LEN
GTH
, TYP
LAP
LEN
GTH
MAS WALL
ADDITIONAL VERT BAR ATINTERSECTION, TYP (4)PLACES
LAP LENGTH
MIN
LAP LENGTH
MIN
LAP LENGTH
MIN
LAP LENGTH
MIN
CORNER BAR TO MATCHWALL HORIZ BARS
CORNER BAR TO MATCHWALL HORIZ BARS
ADDITIONAL VERT BARAT INTERSECTION, TYP(3) PLACES
MAS WALL
LAP LENGTH
PREFORMED "T" QUICK JOINT ORSAWCUT, USE TOOLED JOINTS ATEXT SLABS
4" SLAB ON GRADE
CONTROL JOINT
4" SLAB ON GRADE
CONSTRUCTION JOINT
5" AND 6" SLAB ON GRADE
CONSTRUCTION JOINT
5" AND 6" SLAB ON GRADE
CONTROL JOINT
5" AND 6" SLAB ON GRADE
CONSTRUCTION JOINT
ALTERNATE
EDGE EA SIDE W/ 1/8"RADIUS
EDGE EA SIDE W/ 1/8"RADIUS
JOINT DOWEL; 5/8"Ø x 18" SLIPDOWEL AT 18"oc OR 4 1/2"x4 1/2"DIAMOND DOWEL AT 24"oc ORAPPROVED EQ
BARS CONTTHRU CJ
DISCONTINUEBARS AT COLD CJ
BARS CONTTHRU CJ
PREFORMED "T" QUICK JOINT ORSAWCUT , USE TOOLED JOINTSAT EXT SLABS
INSTALL BACKER RODIMMEDIATELY AFTERSAWCUTTING JOINTS
t
THIC
KNES
S (t)
1/4"
SLA
B
t
2" C
LR
THIC
KNES
S (t)
1/4
SLAB
2" C
LR2"
CLR
INSTALL BACKER RODIMMEDIATELY AFTERSAWCUTTING JOINTS
EDGE EA SIDE W/ 1/8"RADIUS
JOINT DOWEL; 5/8"Ø x 18" SLIPDOWEL AT 18"oc OR 4 1/2"x4 1/2"DIAMOND DOWEL AT 24"oc ORAPPROVED EQ
DISCONTINUE BARS ATCOLD CJ
2" C
LR
1
3 (MIN)
EDGE W/ 1/8" RADIUS
CONC SOG
CONC SOG
CONSTRUCTION JOINT
1
3 (MIN)
EDGE W/ 1/8" RADIUS
CONC SOG
CONC SOG
CONTROL JOINT
SAWCUT
6" MIN
THIC
KNES
S "t"
1/4"
SLA
B
6" MIN
"t""t"
INSTALL BACKER RODIMMEDIATELY AFTERSAWCUTTING JOINTS
#4 x CONT
JOINT DOWEL: 5/8" x 18" SLIPDOWEL AT 18"oc OR 4 1/2 x 4 1/2DIAMOND DOWEL AT 24"oc ORAPPROVED EQUAL
JOINT DOWEL: 5/8" x 18" SLIPDOWEL AT 18"oc OR 4 1/2 x 4 1/2DIAMOND DOWEL AT 24"oc ORAPPROVED EQUAL
#4 x CONT
(2) #4 x 4'-0" BARS AT EA CORNER OFRECESSED OR DEPRESSED SLABSWHERE CONTROL OR CONSTRUCTIONJOINTS DO NOT EXTEND BYNDCORNER
(2) #4 x 4'-0" BARS WHERE CONTROLOR CONSTRUCTION JOINTS DO NOTEXTEND FROM CORNERS OF FLRSLAB BLOCK OUTS AT BLDG COL
(2) #4 x 4'-0" BARS WHERECONTROL OR CONSTRUCTIONJOINTS INTERSECT BUT DO NOTCONT BYND
RECESSED ORDEPRESSED SLAB
CJ
CJ
PLAN VIEW
PLAN VIEW
PLAN VIEW
BLOCK OUT
COL
REINF INSIDE CORNERSSIM TO DEPRESSED SLABS
CONC FND WALL / CONC COL
CONC FTG
EXT FINAL GRADE
INT FINISH FLR
STRUCTURE ABVFINISHED FLR NOTE: CONTRACTOR SHALL
VERIFY AND COMPARE ALLFINAL EXT GRADE ELS W/ TOPOF FTG ELS NOTED TO INSUREMIN REQD FROST DEPTH ISPROVIDED
TYP AT EXT FND PER
GSN
REQ
UIR
ED F
RO
ST D
EPTH
6" M
IN
1'-4" MIN
3d MIN
3d M
IN6"
MIN
END OF CONC WALL
6" M
AX
6" M
AX
PROVIDE TYP WALLHORIZ REINF
PROVIDE TYPHORIZ REINFBTWN SLEEVES
PROVIDE SLEEVE FOR ALLPIPES OR CONDUITS PASSINGTHRU WALLS. 8"Ø MAX
PROVIDE TYP WALL HORIZREINF
d = DIAMETER OF PIPE SLEEVE
FOR PIPE SLEEVE DIAMETERSGREATER THAN 8", SEE TYP TRIMBARS AROUND MISCELLANEOUSCONCRETE WALL OPENINGS
IF SPACING REQUIREMENTSCANNOT BE MET, ENGINEEROF RECORD IS TO BECONTACTED PRIOR TOSLEEVES BEING INSTALLED
BOTT/ CONC
WALL
TOP/ CONC
WALL
MECH HOUSE KEEPING PAD
#3 AT 12"oc, EA WAY
EQUIPMENT CONNECTIONBY OTHERS AS REQD
#3 AT 12"oc, EA WAY
8" MIN
STRUCTURAL FLOOR(CONC OVER MTL DECKOR SOG)
CLR2"
#3 AT 12"oc AROUNDPERIMETER W/ STDHOOK EACH END
NOTE: DET MAY BE USED IN LIEU OF POST-INSTALLED HOUSEKEEPING PAD DET
OPENINGS CLOSER THAN 16" EDGETO EDGE SHALL BE TREATED AS ASINGLE OPENING
MISCOPENING OR
RECESS
FLR OR ROOF LEVEL
(1) #5 AT 8" WALLS(1) #6 AT 10" WALLS(2) #5 AT 12" WALLS
MEASURED FROMEDGE OF OPNG
FLR LEVEL
SEE MAS LINTELSCHED FOR REINF
VERT BARS TO MATCHWALL REINF (BARSTO BE FLR TO FLR)
STANDARD HOOK
LAP LENGTH OR
STANDARD HOOK
LAP LENGTH OR
TRIM BARS NOT REQD FOR OPENINGS6" WIDE OR LESS
3'-0" MAX
SEE MAS LINTELSCHED FOR REINFABV RECESS
RECESS IN WALL
STD 180 DEG HOOK
VERT REINF FULLHEIGHT OF WALL ATEA SIDE OF RECESS
#5 HORIZ BAR BLWRECESS, EXTEND 48BAR Ø EA SIDEOF RECESSED OPNG
PLAN VIEW
SECTION CONDITION AT HORIZONTAL BOND BEAM AND JOINT REINFORCING
HORIZ REINF CONTTHRU JOINT
CONT VERT CJ
(1) VERT BAR TO MATCH VERT WALLREINF, EA SIDE OF JOINT
JOINT MATERIAL DUR-O-WALL WF TYPE (ORAPPROVED EQ) SIZE VARIES BASED ON WALLTHICKNESS, VERIFY W/ ARCH
TYP VERT REINFIN LAST CELL
HORIZ REINF TO TERMINATEW/STD 180 DEG HOOK ATSINGLE LAYER OF VERT REINF
TYP VERT REINFIN LAST (2) CELLS
HORIZ REINF TO TERMINATEW/STD 90 DEG HOOK AT DBLLAYER OF VERT REINF EXTENDBYND VERT REINF
LAP LENGTH
LAP LENGTH
MAS WALL
SINGLE LAYER VERTICAL REINFORCING
DOUBLE LAYER VERTICAL REINFORCING
TIES SEE MAS COL SCHEDCONC BLOCKOUT
(E) CONC WALL
(E) CONC FTG
(E) CONC SLAB
2" MIN4"
TYP
1 1/
2"7"
EDGE OF (E) CONC WALL
EDGE OF (E) CONC FTG
V.I.F.
5"
3/4" THICK BASE PL W/ (4)3/4"Øx4" KWIK HUS-EZ BOLT
1/4
(E) MAS WALL
T/ PIER CAP
VARIES
COL
HSS STL COL
CONC PIER CAP,EXTEND TO (E) WALL
IN THE EVENT OF ABCONFLICT W/ (E) FTG, CHIP(E) FTG OR CORE HOLE TOALLOW FULL EMBEDMENT
(E) FTG, EXTENTVARIES, FIELD VERIFY
S502
C3
HELICAL PIERS BY SUPPLIER
EXTEND PIER CAP DOWNTO ADJACENT (E) FTGWHERE OCCURS
THICKEN FTG AS REQD AT AB'S
PIER CAP BY SUPPLIER TOACHIEVE SPECIFIED LOADING
3" C
LRPI
ER C
AP T
HIC
KNES
S
2'-0
"
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:09:5
3 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
Author09.09.2016
16073
FOOTING
AND
FOUNDATION
DETAILS
S501
09.09.2016PERMIT SET
NO SCALE:S501
D1 TYPICAL SUBGRADE PREPARATIONNO SCALE:S501
D3 TYPICAL PIPE PARALLEL TO FOOTINGNO SCALE:S501
D4 TYPICAL PIPE PERPENDICULAR TO FOOTING
NO SCALE:S501
C1 TYPICAL FOOTING STEP AT CONCRETE FOUNDATION WALLNO SCALE:S501
C2TYPICAL CORNER BARS FOR SINGLE REINFORCEDCONCRETE WALLS (PLAN VIEW)
NO SCALE:S501
C3TYPICAL CORNER BARS FOR SINGLE REINFORCEDMASONRY WALLS (PLAN VIEW)
NO SCALE:S501
C4 TYPICAL SLAB ON GRADE JOINTSNO SCALE:S501
C6 TYPICAL SLAB ON GRADE DEPRESSION DETAILS
NO SCALE:S501
B1TYPICAL SLAB ON GRADE DISCONTINUITIES REQUIRINGADDITIONAL REINFORCING
NO SCALE:S501
D2 TYPICAL FOOTING DEPTH DETAIL FOR FROST PROTECTIONNO SCALE:S501
D5TYPICAL SMALL PIPE OR CONDUIT THROUGH CONCRETEWALL
NO SCALE:S501
B2POST INSTALLED ANCHOR DETAIL FOR HOUSEKEEPINGPAD ON CONCRETE OVER METAL DECK OR SOG
NO SCALE:S501
B3TYPICAL REINFORCING DETAIL FOR MISCELLANEOUSMASONRY WALL OPENINGS AND RECESSES
NO SCALE:S501
A1TYPICAL MASONRY WALL RECESS DETAILS FOR SINGLEREINFORCED MASONRY WALLS (PLAN VIEW)
NO SCALE:S501
A2TYPICAL CONTROL JOINT FOR SINGLE REINFORCEDMASONRY WALLS (PLAN VIEW)
NO SCALE:S501
A3TYPICAL TERMINATION OF HORIZONTAL REINFORCING FORREINFORCED MASONRY WALLS (PLAN VIEW)
NO SCALE:S501
A4 TYPICAL STEEL COLUMN TO EXISTING CONCRETE FOOTING
# Date Revision
NO SCALE:S501
B4 MOMENT FRAME COLUMN TO PIER CAP
A
A
A A
A A
CONC SOG
CONC FTG
VERT WALL REINF
HORIZ WALL REINF
CONT BAR -#5 AT 6" AND 8" THICKMAS WALL
OPTION
SOLID GROUT ALL CELLSBLW GRADE
DOWEL TO MATCH VERTWALL REINF ABV
MAS WALL
HORIZ WALL REINF
HORIZ WALL REINF
ALTERNATE HOOK DIRECTION
8" T
YP
1/4" ROUGHENEDSURFACE
CONC SOG
CONC FTG
HORIZ WALL REINF
BOTT CONT REINFCONC WALL
HORIZ WALL REINF
VERT WALL REINF
TOP CONT REINF
CHAMFER, SEE ARCH
WHERE 'H' EXCEEDS 24"#4 AT 24"
DOWEL TO MATCH VERTWALL REINF ABV
MAS WALLSILL OPTION
CONT #5 BAR
PRECAST CONC SILL, SEEARCH MAS WALL BYND
24" 18"
"H"
ALTERNATE HOOK DIRECTION1/4" ROUGHENEDSURFACE
CONC BLOCKOUT
STL COL
CONC SOG
CONC FTG 1/2"Ø ASTM F1554 GR36HEAVY HEX AB'S
3" M
INC
OVE
R
1/2" STL BASE PL ON 2"OF NON-SHRINK GROUT
1/4
(E) CONC/MASONRY WALL
SECTION A-A
9" E
MBE
D4"
PR
OJ.
1 1/2"
1 1/
2"
TYP1/2"
SEE
PLAN
(2) ADDITIONAL #5 BARS xOPNG + 4'-0". CTRD AT ALLOPNG
CONC SOG
CONC FTG
WALL BYND
#4 'ZEE' DOWEL AT 16"oc
#5 BAR x CONT
1/4" ROUGHENED SURFACE
1
3 (MIN)
JOINT DOWEL: 5/8"Ø x 18" SLIPDOWEL AT 18"oc OR 4 1/2 x 4 1/2DIAMOND DOWEL AT 24"oc ORAPPROVED EQUAL
SEE ARCH FOR
OPENING CONFIGURATION
CONC SOG
EXT SLAB OR GRADE
T&B CONT REINF
DOWEL TO MATCH VERTWALL REINF ABV
CONC FTG
CONC WALL
1
3 (MIN)
WALL BYND24" 18"
#4
1/4" ROUGHENED JOINT
8" T
YP
#4 x CONT. EXTEND 4'-0" MINEA END BEYOND OPENING
SLOPE
#4 x 4'-0" AT 18"oc
1/4" ROUGHENED SURFACE
1
3
AT WALL VERT REINF
2'-0"
(2) CONT #5 BARS
#4 CONT AT 12"ocHOOK DOWN ATEDGE OF STAIRS
6" M
IN
10"
#4 BARS AT 12"oc,MAYBE FIELD BENT (1) TIMEONLY, EA BEND
2x4 x CONTKEYWAY
CONC SOG
SECTION A-A
SEE ARCHFOR RAILING
CONT #4 BARAT 12"oc
(2) CONT#5 BARS
SEE ARCH FOR RISEAND RUN OF STAIRS
CONC STEM WALL(CW-08A)
CONC FTG
2x4 KEYWAY, TYP
DOWEL TO MATCHWALL REINF
CONC SOG
CONC SOG
CONC SOG
AT RAMPELIMINATE STEP
1'-0
"
8"
1'-0
"
CONC SOG
CONC FTG
HORIZ WALL REINF
BOTT CONT REINF
CONC WALL
HORIZ WALL REINF
VERT WALL REINF
TOP CONT REINF
WHERE 'H' EXCEEDS 24"#4 AT 24"
DOWEL TO MATCH VERTWALL REINF ABV
MAS WALL
24" 18"
1/4" ROUGHENEDSURFACE TYP
VERT REINF PER SCHED ONDETAIL /(C5 S301)
CONC SOG
SEE ARCH
SEE ARCH
CONC BLOCKOUT
STL COL
CONC FTGAB'S
STL BASE PL ON 2"NON-SHRINK GROUT
T/CONC SOG
SEE ARCH DWGS
T/FTG
CLR3" THICKEN FTG AT AB'S
1'-9
" EM
BED
PRO
J.
6"
(E) CONC SLAB. SAWCUT ASREQ'D FOR INSTALLATIONOF FTG
C5
S502
(2) HEAVY HEX NUTS W/ PLWASHER AT EA BOLT.AT HSS20x20:1 1/2"x5 1/2" SQ PL WASHERAT HSS12x12:1"x4" SQ PL WASHER
BASE PLATE FOR HSS20x20 BASE PLATE FOR HSS12x12
3" 50ksi BASE PL
3/4"x5" SQ PL WASHER, TYP
5 1/
2" T
YP
TYP
1'-3
1/2
"
TYP
1'-3
1/2
"5
1/2"
TYP
TYP
1'-9
"
TYP
1'-9
"
COL
4" T
YP
TYP
10"
TYP
10"
4" T
YP
TYP
1'-2
"
TYP
1'-2
"
CJP DCW
5/16TYP
CJP DCW
5/16TYP
2" 50ksi BASE PL
1/2"x3 1/2" SQ PL WASHER,TYP
(8) 3" HOLES FOR 2"ØASTM F1554 GR 105 AB'S
(8) 2 1/4" HOLES FOR 1 1/2"ØASTM F1554 GR 105 AB'S
STL COL TYP
FILL BOLT HOLES W/ NON-SHRINK GROUT PRIOR ROPLACING PL WASHER, TYP
COL
COL
PROVIDE INTERMEDIATEVERT #5 MAX SPACINGAT 32"oc
NEW MASONRY INFILL,SIZE TO MATCH (E)
PROVIDE MIN (1) #5 VERTAT EA EDGE OF INFILL
PROVIDE HORIZ #5 ATMIN SPACING OF 48"oc
#5 DOWEL TO BE EPOXIED INTO(E) SOLID GROUTED CELLS
TYP
6" M
IN
4"
TYP
4"
VERIFY W/ (E) 2'-0" MIN
1'-6"
2'-0
"
SECTION A-A
HSS JAMB/COL, SEE PLAN
NOTCH (E) FDN WALL AS REQ'D
3/4"x9"x12" BP W/ (2) 3/4" EPOXYAB W/ 6" EMBEDMENT OR CASTIN AB 9" INTO PIER
NEW SOG, SEE PLAN
TYP TIE "U" BAR
(E) CMU WALL, SEE PLAN
(E) FND, VERIFY W/ (E)
MIN8"
2'-0"x1'-6" PIER W/ (7) #5 BAR(VERT) W/ #4 TIES AT 6"oc
(2) LAYERS #4 AT 12"oc MAX SPACING EW
4'-0" LONG ADD FTG CENTEREDAT HSS COL LOC
AT SIM COND, TERMINATE CONC PIER AT TOPOF PIER CAP, EXTEND VERTS THRU CAP
TOP OF PIER CAP WHERE OCCURS
TYP
EQ EQ
CONC FTG
CONC WALLEXT SOG TYP
1/4" ROUGHENED SURFACE
1/4" ROUGHENEDSURFACE, TYP
PLACE REBAR AT SOIL SIDE OFWALL, TYP SEE CONC WALLSCHED ADD'L INFORMATION
SEE ARCH
TYP
DRILL AND EPOXY#4 BAR W/ 4" MINEMBEDMENT
#4 HORIZ x CONT TYP
TYP
Ldh
MIN
TYP
LAP
SPLI
CE
TYP
8"
SEE ARCH
CONC SOG, REINF SAME ASDOCK SLAB
DOCK SOG, SEE PLAN FORREINF
24" 18"
#4 AT 24"oc
24" 18"
#4 AT 24"oc
CONC FTG
CONC WALL
CONC SOG
1/4" ROUGHENED SURFACE
1/4" ROUGHENEDSURFACE, TYP
PLACE REBAR AT SOIL SIDE OFWALL, TYP SEE CONC WALLSCHED FOR ADD'L INFORMATION
SEE PLAN
#4 HORIZ x CONT TYP
TYP
LAP
SPLI
CE
DOCK SOG, SEE PLAN FORREINF
24" 18"
#4 AT 24"oc
8"
STL COL
3/4" BASE PL ON 1 1/2"NON-SHRINK GROUT
EXT SOG
14"x14" CONC PIER W/ (4) #5AND #4 TIES AT 6"oc, EPOXYBARS INTO (E) FTG ASREQUIRED 6" MIN
EPOXY FTG BARS INTO(E) FTG 10" MIN
(E) MAS WALL
(E) CONC WALL
(E) FTG
5"
8"
SECTION A-A
4" 1 1/2"
9"1
1/2"
SOG
CONC WALL
FINISH, SEE ARCH
EXT SOG
CONC FTG
(E) MAS WALL
T/ PIER CAP
VARIES
COL
HSS STL COL
CONC PIER CAP,EXTEND TO (E) WALL
IN THE EVENT OF ABCONFLICT W/ (E) FTG, CHIP(E) FTG OR CORE HOLE TOALLOW FULL EMBEDMENT
(E) FTG, EXTENTVARIES, FIELD VERIFY
9" M
AX6"
MIN
S502
C3
HELICAL PIERS BY SUPPLIER
EXTEND PIER CAP DOWNTO ADJACENT (E) FTGWHERE OCCURS
THICKEN FTG AS REQD AT AB'S
3" C
LR
CORE FTG AS REQD TO ALLOWINSTALLATION OF HELICAL PIERS.PACK CORED HOLE W/ CONC
PIER CAP BY SUPPLIER TOACHIEVE SPECIFIED LOADING
4"4"
LAP (TYP)
#4 BAR DRILLED AND EPOXIED INTO(E) MAS WALL W/ 8" EMBED (TYP)AT HORIZ REINF
MAS WALL VERT REINFNOT SHOWN
(E) MAS WALL REINFNOT SHIOWN
(E) FTG REINFNOT SHOWN
CONC FTG
#5 BARS DRILLED ANDEPOXIED INTO (E) FTGW/ 10" EMBED LAP W/NEW FTG REINF
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:09:5
6 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
Author09.09.2016
16073
FOOTING
AND
FOUNDATION
DETAILS
S502
09.09.2016PERMIT SET
NO SCALE:S502
D3TYPICAL SINGLE MAT REINFORCING MASONRY WALL ONINTERIOR CONCRETE FOOTING
NO SCALE:S502
D1TYPICAL SINGLE MAT REINFORCING MASONRY WALL ONCONCRETE FOUNDATION WALL
NO SCALE:S502
D6 TYPICAL STEEL COLUMN TO CONCRETE FOOTINGNO SCALE:S502
D4 TYPICAL INTERIOR WALL OPENING DETAIL AT 8" WALLSNO SCALE:S502
D2 TYPICAL FOUNDATION WALL AT OPENING
NO SCALE:S502
C1 CONCRETE STAIR OR RAMP DETAILNO SCALE:S502
C2TYPICAL SINGLE MAT REINFORCING MASONRY WALL ONCONCRETE FOUNDATION WALL AT STEP
NO SCALE:S502
C3 HSS MOMENT FRAME COLUMN TO CONCRETE FOOTINGNO SCALE:S502
C5 MOMENT FRAME BASE PLATE DETAIL
# Date RevisionNO SCALE:S502
B1 TYPICAL EXISTING MASONRY WALL INFILLNO SCALE:S502
B2 TUBE STEELNO SCALE:S502
B4 CONCRETE WALL AT PLAZANO SCALE:S502
B6 CONCRETE WALL AT DOCK AREA
NO SCALE:S502
A1 STEEL COLUMN AT (E) WALLNO SCALE:S502
A2 TICKET WINDOW FOOTING WALLNO SCALE:S502
A3 MOMENT FRAME COLUMN TO PIER CAPNO SCALE:S502
A5 NEW MASONRY WALL TO EXISTING MASONRY WALL
A
A
A
A
NOTES:1. NAILING SCHEDULE IS PER TABLE OF THE I.B.C.2. NAILING REQUIREMENTS SHOWN HERE DO NOT REPLACE HARDWARE ON THE PLANS OR DETAILS.3. ALL NAILS USED ARE COMMON NAILS, UNO.
MINIMUM NAILING SCHEDULECONNECTION NAILING
BRDG TO JST, TOE NAIL EA ENDSOLE PL TO JST OR BLK, FACE NAILTOP PL TO STUD, END NAILSTUD TO SOLE PL, END NAILDBL STUDS, FACE NAILDBL TOP PL, FACE NAILBLK BTWN JST OR RAFTERS TO TOP PL, TOE NAILRIM JST TO TOP PL, TOE NAILTOP PL, LAPS AT WALL INTERSECTION, FACE NAILCONT HEADER, TWO PIECESCEILING JST TO PL, TOE NAILCONT HEADER TO STUD, TOE NAILCEILING JST, LAPS OVER PARTITIONS, FACE NAILCEILING JST TO PARALLEL RAFTERS, FACE NAILRAFTER TO PL, TOE NAIL1" BRACE TO EA STUD AND PL, FACE NAILBUILT-UP CORNER STUDSBUILT-UP GIRDER AND BM
COLLAR TIE TO RAFTER, FACE NAILJACK RAFTER TO HIP, TOE NAIL
FACE NAILROOF RAFTER TO 2x RIDGE BM, TOE NAIL
FACE NAILJST TO BAND JST, FACE NAILLEDGER STRIP, FACE NAIL AT EA JOISTPLYWOOD AND PARTICLEBOARD:
SUBFLOOR, ROOF AND WALLSHEATHING (TO FRAMING)
1/2" AND LESS19/32" - 1"1 1/8" - 1 1/4
COMBINATION SUB FLOOR -UNDERLAYMENT (TO FRAMING)
3/4" AND LESS7/8" - 1"1 1/8" - 1 1/4"
NAILS SPACED AT 6 INCHES ON CENTER AT EDGES, 12INCHES AT INTERMEDIATE SUPPORTS, EXCEPT 6" INCHESAT ALL SUPPORTS WHERE SPANS ARE 48 INCHES ORMORE. FOR NAILING OF DIAPHRAGMS AND SHEAR WALLS,REFER TO THE APPROPRIATE SCHEDULE.
(2) 8d16d AT 1'-4"oc(2) 16d(2) 16d16d AT 2'-0"oc16d AT 1'-4"oc(3) 8d8d AT 0'-6"oc(2) 16d16d AT 1'-4"oc ALONG EA EDGE(3) 8d(4) 8d(3) 16d(3) 16d(3) 8d(2) 8d16d AT 2'-0"oc3" x 0.131 AT 24"oc AT TOP AND BOTTAND STAGGERED, (3) 3" x 0.131 ATENDS AND AT EA SPLICE(3) 10d(3) 10d(2) 16d(2) 16d(2) 16d(3) 16d(3) 16d
8d8d OR 10d10d
8d8d OR 10d10d
SHEATHING SCHEDULE AT ROOF AND FLOOR
NOTES:1. ALL ROOF SHEATHING SHALL BE APA RATED SHEATHING WITH A MINIMUM SPAN RATING OF 40/20. USE OSB INSTEAD OF PLYWOOD UNLESS
OTHERWISE APPROVED BY THE EOR.2. NAIL ROOF SHEATHING TO SUPPORTS. GLUE AND NAIL FLOOR SHEATHING TO SUPPORTS.3. USE COMMON NAILS (8d DIAMETER = 0.131”, 10d DIAMETER = 0.148”). MINIMUM NAIL PENETRATION INTO FRAMING MEMBERS, 8d = 1 1/2”, 10d = 1 5/8”.4. DRIVE NAILS WITH NAIL HEADS FLUSH WITH THE SURFACE OF THE SHEATHING. DO NOT OVER DRIVE OR UNDER DRIVE NAILS. EDGE NAILS SHALL BE
PLACED 3/8” FROM EDGE OF PANEL.5. PANEL EDGES PERPENDICULAR TO SUPPORTS SHALL BE UNBLOCKED UNLESS FULLY BLOCKED IS SPECIFICALLY NOTED. PROVIDE PANEL EDGE
NAILING AS SPECIFIED ALONG ALL SUPPORTED EDGES (ALL EDGES IF FULLY BLOCKED), BOUNDARIES, TOP PLATES OF SHEAR WALLS, STRAPS,COLLECTORS, AND AT ALL OTHER LOCATIONS AS INDICATED AND/OR REQUIRED FOR A COMPLETE INSTALLATION.
6. PROVIDE FIELD NAILING AT 12”oc TYPICAL FOR ALL DIAPHRAGMS.7. ALL SHEATHING PANELS SHALL HAVE A MINIMUM WIDTH OF 2’-0”, UNLESS PANEL IS FULLY BLOCKED AND NAILED TO ADJACENT PANELS.8. PLACE ALL SHEATHING PANELS JOINTS ALONG THE CENTER OF A SINGLE COMMON BACK-UP MEMBER, TYPICAL.9. 10. EXTERIOR FLOOR SHEATHING SHALL BE PLYWOOD (NOT OSB) WHEN REQUIRED BY THE ARCHITECT.
OTHER EDGE
STAGGER JOINTS
CONT EDGE
FIELD NAILING
1/16
" GAP
AT
SID
E JO
INTS
EDGE OF PLYWOOD SHEETSCTR ON JSTS AND BLOCKS
1/8" GAP AT END JOINTS
LEDGER
BN
EN
EDGE BLK, WHERE NOTEDIN SCHED, USE 2x4 FLATBLK, UNO
LOCATIONWOOD
SHEATHINGTHICKNESS
NAIL SIZEEDGE NAIL
CONT EDGE OTHER EDGE
EDGEBLOCK
BOUNDARYNAIL
FIELDNAIL
ROOF 19/32" 8d 6" 6" 6"12" NO
SEE SW SCHED FOR AB SIZEAND SPACING. USE 5/8"Ø AT48"oc ELSEWHERE TYP, UNO
D = 6" MIN, 12" MAX
'D' 'D'
EQ
ALL AB TO HAVE A 6" MINEMBEDMENT TO TOP OF J-BOLTOR NUT, TYP UNO
'D'
'D'
WHERE SOLE PL IS DRILLEDOR NOTCHED MORE THAN 1/3WIDTH, INSTALL AB EA SIDEOF NOTCH
"D"
SPLICE"D"
PT/DF SOLE PL
EQ EQ
(2) 2x4 STUDS (3) 2x4 STUDS (4) 2x4 OR MORE STUDS
10d NAILS 30d NAILSOR SDW22438 SCREWS
1/2"Ø BOLTS W/ WASHERSOR SDW22600 SCREWS
(4 PLY ONLY)
2 1/
2"
1"
3 1/
2"
1 1/2"
(2) 2x6 OR GREATER STUDS (3) 2x6 OR GREATER STUDS (4) 2x6 OR GREATER OR MORE STUDS
2 1/
2"6"
TYP
1"
3 1/
2"8"
TYP
1 1/2"
8" T
YP
2" FOR GREATER1 1/2" FOR 2x6
4"
6" T
YP
6" T
YP
10d NAILS 30d NAILSOR SDW22438 SCREWS
1/2"Ø BOLTS W/ WASHERSOR SDW22600 SCREWS
(4 PLY ONLY)
8" T
YP
1 3/4" 1 3/4"
4"
= NAIL NEAR SIDE
= NAIL FAR SIDE
THIS DTL DOES NOT APPLY TO MULTIPLESTUDS IN SHEATHED WALL.AT MULTIPLE STUDS IN WALLS PROVIDE(1) ROW 16d NAILS AT 8"oc IN 2x4 WALLSOR (2) ROWS 16d NAILS AT 8"oc IN 2x6 OR2x8 WALLS.
1. L = CLEAR SPAN OF JST / BEAM.2. NO NOTCHING PERMITTED IN STUDS.3. NO HOLES OR NOTCHES PERMITTED IN
BEAMS WHICH ARE LESS THAN 6" DEEP.4. NO NOTCHES IN GLU-LAMS WITHOUT PRIOR
APPROVAL FROM ENGINEER.5. FOR LVL AND I-JST REFER TO
MANUFACTURERS REQUIREMENTS.
dj /
6 M
AX
L/3 MAXNO NOTCHES
STUD
ds 2dj MIN
MAX
dj/3
JST/
BMdj
2" M
IN2"
MIN
2" M
AXdj
/3
L/3 MIN dj MIN
NO HOLESEQ EQ
MINds
ds / 4 MAX
L
STUD
BEAM
dj MIN
UPPER PL SPLICE
(20) 16d NAILS MIN EA SIDEOF EA SPLICE
DBL TOP PL SPLICESSHALL OCCUR OVERSTUDS, TYP UNO
MIN
4'-0"
WALL STUDS
LOWER PL SPLICE
SHTGTHICKNESS
BOTHSIDES
SHEATHED
NAILSIZE
STUD/ BLKG ATJOINT
SILL NAILINGAT BOTT OF WALL
(SEE NOTE 15)
SOLE BOLTINGTO CONCRETE(SEE NOTE 12)
MARKEDGE NAIL
(EN)
SHEAR WALL SCHEDULE
SW-1
SW-2
SW-3
7/16"
7/16"
7/16"
NO
NO
NO
8d
8d
8d
6"
4"
3"
2x (1) 16d AT 8"oc
3x
3x
(1) 16d AT 5"oc
(1) 16d AT 4"oc
5/8"Ø AT 48"oc
5/8"Ø AT 40"oc
5/8"Ø AT 32"oc
FRAMING ANCHORAT TOP OF WALL
(SEE NOTE 15)
(1) A35 AT 16"oc
(1) A35 AT 16"oc
(1) A35 AT 16"oc
EN
HDU WHEREAPPLIES
FIELD NAIL
EN INTO HDPOST1/
16" G
AP A
T SI
DE
JOIN
TS
1/8" GAP AT END JOINTSSW/EN TO UPPER TOP PL
BLK ALL JOINTS
SOLE PL, USE 3xWHERE BOTH SIDESARE SHEATHED
EDGE OF WOODSHEATHING SHEETS CTRON STUDS AND BLKS
EN
JOINT STUD, USE 3x WHEREREQD BY SCHED
WOOD SHEATHING SHEETSMAY BE INSTALLEDVERTICALLY
TYP ELEVATION
STUD AND BOLT
PL WASHER 1/4"3"x REQD W/SLOTTED HOLE
ANCHOR BOLT, STD WASHERAND NUT
PT/DF SOLE PL
1/2" MAX 1/2" MAX
STUD AND BOLT
PL WASHER 1/4"3"x3" W/SLOTTED HOLE
ANCHOR BOLT, STDWASHER AND NUT
PT/DF SOLE PL
1/2" MAX
SW SHTG
(1) PLY (2) PLY
SW SHTG
TYPICAL ANCHOR BOLTS AT SHEAR WALLS (PLAN VIEW)
NOTES:1. ALL WALL SHEATHING SHALL BE APA RATED SHEATHING WITH A MINIMUM SPAN INDEX OF 24/16. USE OSB INSTEAD OF PLYWOOD UNLESS OTHERWISE APPROVED BY THE EOR.2. ALL EXTERIOR WALLS SHALL BE SHEATHED WITH 7/16" SHEATHING AND NAILED WITH 8d NAILS AT 6”oc AT PANEL EDGES AND AT 12”oc IN THE FIELD, TYPICAL, UNO. SEE SHEAR WALL
SCHEDULE FOR ADDITIONAL REQUIREMENTS.3. SHEATHING AT EXTERIOR WALLS MAY NEED TO BE FIRE-TREATED. SEE ARCHITECTURAL DRAWINGS.4. USE COMMON NAILS (8d DIAMETER = 0.131”, 10d DIAMETER = 0.148”). MINIMUM NAIL PENETRATION INTO FRAMING MEMBERS, 8d = 1 1/2”, 10d = 1 5/8”.5. DRIVE NAILS WITH NAIL HEADS FLUSH WITH THE SURFACE OF THE SHEATHING. DO NOT OVER DRIVE OR UNDER DRIVE THE NAILS. EDGE NAILS SHALL BE PLACED 3/8” FROM EDGE OF
PANEL.6. ALL PANEL EDGES SHALL BE FULLY BLOCKED, UNO. PROVIDE PANEL EDGE NAILING AS SPECIFIED ALONG ALL PANEL EDGES, UPPER TOP PLATES, SILL PLATES, HOLD-DOWN
ELEMENTS, STRAPS, COLLECTORS, AND AT ALL OTHER LOCATIONS AS INDICATED AND/OR AS REQUIRED FOR A COMPLETE INSTALLATION.7. PROVIDE FIELD NAILING AT 12”oc TYPICAL FOR ALL SHEATHED WALLS.8. PLACE ALL SHEATHING PANELS WITH A 1/8” GAP AT END JOINTS, 1/16" GAP AT SIDE JOINTS. PLACE ALL SHEATHING PANEL JOINTS ALONG THE CENTER OF A SINGLE COMMON BACK-
UP MEMBER, TYPICAL (EXCEPT AS NOTED BELOW). SEE SCHEDULE FOR THICKNESS REQUIREMENTS FOR BACK-UP MEMBER (STUDS, BLOCKING). AS AN ALTERNATE, (2) 2x MEMBERSMAY BE USED INSTEAD OF A 3x MEMBER FOR STUDS, PLATES, OR BLOCKING AT SHEATHING PANEL JOINTS PROVIDED THE (2) 2x MEMBERS ARE STITCH NAILED WITH 16d NAILS ATSPACING TO MATCH THE PANEL EDGE NAIL PACING SHOWN IN THE SCHEDULE.
9. DO NOT SPLICE SHEATHING ALONG TOP PLATES OR SILL PLATES UNLESS THE PLATE MEETS THE MINIMUM THICKNESS INDICATED IN THE SCHEDULE.10. AT WALLS WITH SHEATHING ON EACH FACE OF THE WALL, STAGGER ALL PANEL JOINTS ON ONE FACE OF THE WALL FROM THE PANEL JOINTS ON THE OTHER FACE OF THE WALL,
BOTH HORIZONTAL AND VERTICAL JOINTS.11. SOLE PLATES AT THE FOUNDATION LEVEL SHALL BE 2x MATERIAL, EXCEPT WHEN BOTH FACES OF THE WALL ARE SHEATHED THEY SHALL BE 3x MATERIAL, TYPICAL, UNO.12. ALL ANCHOR BOLTS IN SOLE PLATES SHALL BE POSITIONED AND TIED INTO PLACE PRIOR TO CASTING CONCRETE. PLACE ANCHOR BOLTS ALONG CENTERLINE OF STUD WALL. SHIFT
LAYOUT OF STUDS AS REQUIRED TO MISS ANCHOR BOLTS. PROVIDE A PLATE WASHER BELOW EACH ANCHOR BOLT NUT. THE PLATE WASHER SHALL EXTEND TO WITHIN 1/2” OF THEFACE OF THE SHEATHING. MINIMUM SIZE OF PLATE WASHER SHALL BE 3”x3”x1/4”. HOWEVER, AT WALLS WITH SHEATHING ON EACH FACE OF THE WALL, THE PLATE WASHER WILLNEED TO EXTEND TO WITHIN 1/2" OF EACH FACE OF SHEATHING. PLATE WASHERS MAY HAVE A DIAGONALLY SLOTTED HOLE WITH A WIDTH OF UP TO THE DIAMETER OF THE BOLTPLUS 3/16” AND A LENGTH OF 1 3/4” PROVIDED A STANDARDCUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. ANCHOR BOLTS SHALL HAVE 6” MINIMUM EMBED TO THE TOP OF THE J-BOLT OR NUT.
13. PROVIDE A HOLD-DOWN AT EACH END OF EACH SHEAR WALL. SEE THE TYPICAL SHEAR WALL AND HOLD-DOWN DETAILS. PLACEMENT OF HOLD-DOWNS SHALL ALLOW FOR THECORRECT NUMBER OF TRIMMER AND KING POSTS AT OPENINGS.
14. WHERE PERPENDICULAR SHEAR WALLS MEET AT A COMMON CORNER, USE THE LARGER HOLD-DOWN SPECIFIED FOR EACH WALL AND NAIL THE SHEATHING FROM EACH WALL TOTHE HOLD DOWN POST. IF SHEATHING FROM BOTH WALLS CANNOT ATTACH TO THE SAME HOLD-DOWN POST, INSTALL BOTH HOLD-DOWNS. AT CONTINUOUS ANCHOR ROD TYPEHOLD DOWNS, INSTALL BOTH HOLD DOWNS.
15. THE SILL NAILING AND FRAMING ANCHOR PORTIONS OF THE SCHEDULE ONLY APPLY WHERE VERTICAL WALL SHEATHING IS INTERRUPTED BY FLOOR FRAMING ELEMENTS. IN CASESWHERE SILL NAILING IS NOT REQUIRED, SILL PLATES SHALL BE FASTENED TO WOOD BELOW WITH 16d NAILS AT 8”oc. WHERE REQUIRED SILL NAILING IS 6"oc OR LESS (EFFECTIVE),RIM BOARD SHALL BE 3 1/2" WIDE LVL MEMBERS OR REQUIRED WIDTH PER MANUFACTURER. SEE BEARING WALL FRAMING SCHEDULE FOR TYPICAL RIM BOARD.
SW-4 7/16" NO 8d 2" 3x (1) 16d AT 3"oc 5/8"Ø AT 24"oc(2) A35 AT 16"oc
SW-5 7/16" YES 8d 4" 3x (2) 16d AT 5"oc 5/8"Ø AT 24"oc(2) A35 AT 16"oc
SW-6 7/16" YES 8d 3" 3x (2) 16d AT 4"oc 5/8"Ø AT 16"oc(2) A35 AT 16"oc
NOTE:WHERE SHEAR WALL SHEATHING (DASHED LINE) IS SHOWN CONTINUOUSACROSS OPENINGS ON PLAN, PROVIDE STRAPS PER DETAIL ABOVE. STRAPSARE NOT REQUIRED BETWEEN INDIVIDUAL SHEAR WALLS.
KING STUD
HEADER, SEE PLAN
SIMPSON STRAP ASINDICATED, TYP
DBL 2x X CONT SILL PLNO SPLICE
EDGE NAIL SHEATHING ALLAROUND OPNG FULL HEIGHTOF KING STUD AND FULLLENGTH OF BLOCKS
2x FLAT BLOCK TO RECEIVESTRAP NAILING TYP
SPAN (ft) SIZENUMBER OFTRIM STUDS
NUMBER OFKING STUDS
SPANSIZE
NUMBER OFTRIM STUDS
NUMBER OFKING STUDS
EXTERIOR WALL INTERIOR WALL
0'-0" > < 3'-0" (3) 2x8 1 2 0'-0" > < 3'-0" (3) 2x8 1 2
3'-0" > < 5'-0" (3) 2x10 2 2 3'-0" > < 5'-0" (3) 2x10 2 2
HEADER SCHEDULE
5'-0" > < 6'-6" (3) 1 3/4 x 9 1/2 LVL 2 3 5'-0" > < 6'-6" (3) 1 3/4 x 9 1/2 LVL 3 2
SEE PLANSEE PLAN> 6'-6" >6'-6"
CONT PL
BRG STUD(S)KING STUD(S)
'SIMPSON' LCE4 POSTCAP, FILL ALL HOLESW/ 16d NAILS
(4) 16d NAILS EAEND OF HEADER
WOOD BM, USE SHTGAS FILLER AS REQD,SEE DTLFOR NAILING
SECTION A-A
CRIPPLE STUDS
WOOD BM
/(A2 S510)BRG STUDS FOR OPNGABV, WHERE OCCURS
SQUASH BLKG ATALL BRG STUDS
ROOF FRAMING
DBL TOP PL
SECTION A-A
QUADRUPLE 2x
DOUBLE 2x TRIPLE 2x
2'-0"
1'-0" 1'-0"
(2) ROWS 1/2"Ø THRUBOLT AT 24"oc ONE EAEDGE, STAGGERED(OR SDW22600)
2"2"
WOOD BEAM NOTES:1. BUILT-UP LVL BEAMS SHALL BE CONNECTED
PER MANUFACTURER'S GUIDELINES.
3" x .131" AT 24"oc EA EDGE,STAGGERED TYP,(3) 3" x .131" AT ENDS
2"2"
3" x .131" AT 24"oc EAEDGE, STAGGERED TYP,(OR SDW22438 SCREWS)(3) 3" x .131" AT ENDS
DOUBLE I JST
10d WEB FILL NAILING AT 12"ocEA FACE TOP AND BOTT
(2) 3/4" WOOD PANELS OR2x FILLER BLK
2"2"
2"2"
CONC FTG
CONC WALL
CONC SOG
STUD WALL
PT/DF SOLE PLEN
SW SHTGAB PER SW SCHED
EXT SLAB OR GRADE
1/4" ROUGHENED SURFACE
EXT FINISH, SEE ARCH
FRO
ST D
EPTH
PER
GSN
SEE
ARC
H
GYP PER ARCH
2x2 PT/DF NAILER
EMBE
D
6"
6" M
IN
SEE ARCH
ROOF SHTGBN
PFT
HDR WHEREOCCURS
H1 OR SDWC EA JOIST
A35 AT 32"oc
DBL TOP PL
STUD WALL
2x FLAT BLKG W/ (2)16d NAILS AT 12" oc
EN
RAILING, SEEARCH
LIGHT BAR, SEEARCH
SEE ARCH
ROOF SHTG
BN
HDR WHERE OCCURS2x LEDGER
DBL TOP PL
STUD WALL
2x BLKG
EN
16d AT 6"oc
EN
CONC FTG
CONC WALL
CONC SOG
EXT RETAINED SOIL
1/4" ROUGHENED SURFACE
SEE
ARC
H
EMBE
D
6"
PLACE REBAR ATSOIL SIDE OF WALL,SEE CONC WALLSCHED
FOR INFORMATION NOT SHOWNHERE SEE DETAIL /(A3 S510)
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:09:5
8 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
Author09.09.2016
16073
WOOD
FRAMING
SCHEDULES
AND DETAILS
S510
09.09.2016PERMIT SET
NO SCALE:S510
D1 MINIMUM NAILING SCHEDULENO SCALE:S510
D2 SHEATHING SCHEDULE AT ROOF AND FLOOR
NO SCALE:S510
D3 TYPICAL SOLE PLATE BOLTING TO CONCRETE (PLAN VIEW)NO SCALE:S510
D4 TYPICAL BUILT-UP 2x WOOD COLUMN CONNECTIONS
NO SCALE:S510
C1 TYPICAL PERMITTED NOTCHES AND HOLESNO SCALE:S510
C2 TYPICAL TOP PLATE SPLICENO SCALE:S510
C3 SHEAR WALL SCHEDULE AND TYPICAL DETAILS
NO SCALE:S510
A1 HEADER SCHEDULENO SCALE:S510
A2 TYPICAL BUILT-UP WOOD BEAM CONNECTIONSNO SCALE:S510
A3 TYPICAL PERIMETER WALL AT CONCRETE WALLNO SCALE:S510
A5 PFT AT PERIMETER BEARINGNO SCALE:S510
A6 BLOCKING AT PERIMETER BEARING
# Date Revision
NO SCALE:S510
A4 TYPICAL PERIMETER WALL AT CONCRETE WALL
A A
SEE ARCH FOR RAILING
GALV. GRATING
STL BM
1/4"x5 1/2"xCONT KICK PLATETYP BOTH SIDES OF CATWALK
1/4
KICK PL TO RAILPOST
1/4POST TO BM
HSS STRUT
HSS CAP PL PERDETAIL
HANGING HSS COL,SEE PLAN
CATWALK BM
1/4(3) SIDES
3/16PJP CAP PL
/(D1 S601)
GALV. GRATING
GALV. GRATING
HANGING STL HSS COL, SEE PLAN
STL BM
WP
SECTION A-A
3/16
1/4" CAP PL/ERECTION AID
2 1/4" MIN
1/4(3) SIDES
1/4HANGING COL TO PL
ROOF DECK NOTSHOWN FOR CLARITY
STIFF PL BOTHSIDES, PER GSN
HSS HANGING COL,SLOT HSS OVER PLSLOT WIDTH = PLTHICKNESS +1/8"
STL BM
PL 5/8"x8"x10" KNIFEDTHROUGH HSS COL
5/16
5/16PL TO BM
CAP PL BOTHSIDES OF KNIFEPL
3/16HSS TO PL
STEP DOWN
STEP UP
HSS BM L2x2X1/4 x 0'-6" AT BM LOC
3/16
3/16
GRATING
1/4" CAP PL
1/4" CAP PL
HSS BM
GRATINGPL 1/4x1 1/4 x CONT
3/16 2-12
HSS6x4x3/16 BLKG
HSS BM
BTWN BMS
PL 1/4x1 1/4 x CONT
2-12
2-12
3/16 2-12
PLAN VIEW
ELEVATION VIEW
± 4"
HSS6x4x1/4 CATWALK BEAM
HSS20x20 MOMENT FRAME COL
HSS6x4x1/4 CATWALK BEAM,GRATING NOT SHOWN FORCLARITY
1/4
ROOF FRAMING
TOP
3/16TYP
PL 1/2x6" SQ, TYP
HSS4x4x1/4 BRACE, TYP6" MAX
SEE (S701) FOR ROOFFRAMING DETAILS
3/16
BOTTOM S601
D1 TYP
HSS4x4x1/4 BRACE
3/16
PL 1/2x6" SQ
3/16
MIN3"
ROOF FRAMING
PL 1/2 x 6" SQ,TYP
HSS4x4x1/4 BRACE, TYP
3/16TYP
3/16TYP
SEE (S701) ROOFFRAMING DETAILS
HANGING STL COL
GALV GRATING
ROOF FRAMING
S601
C3
SEE (S701) FOR ROOFFRAMING DETAILS
PL 1/2 x 6" SQ,TYP
HSS4x4x1/4 BRACE,TYP
3/16TYP
3/16TYP
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:10:0
0 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
Author09.09.2016
16073
CATWALK
FRAMING
DETAILS
S601
09.09.2016PERMIT SET
NO SCALE:S601
D2 RAILING TO CATWALK BEAMNO SCALE:S601
D3 TYPICAL STRUT CONNECTION AT CATWALK LEVEL CHANGENO SCALE:S601
D1TYPICAL BEAM TO BEAM CONNECTION AT CATWALKHANGING COLUMN
NO SCALE:S601
D4 HANGING HSS COLUMN TO BEAM DETAIL
# Date Revision
NO SCALE:S601
D5 CATWALK STEP DETAIL
NO SCALE:S601
C1 CATWALK BEAM TO MOMENT FRAME COLUMNNO SCALE:S601
C2 NORTH / SOUTH CATWALK BRACINGNO SCALE:S601
C3 WEST CATWALK BRACINGNO SCALE:S601
C4 EAST CATWALK BRACING
OPEN
A
A
A SIM
A SIM
OPEN OPEN OPEN
OPEN
MECH UNIT, SEE MECH DWGS
(2) L5x3x1/4 (LLV) USE UNISTRUT FORUNITS WEIGHING LESS THAN 300#
L6x4x5/16 x 0'-10" (LLV) TYP
HANGING RODS, SEE MECHCONTRACTOR
5 1/2"x3" SPACER PL 1/16" THICKERTHAN HANGING RODS AT THIRDPOINTS
MTL ROOF DECK
(FOR UNITS WEIGHING 2500#'S OR LESS)
1/4TYP
1/4
1/4
3/16
PLAN VIEW
PIPE SLEEVE
18ga PL W/ #10 SHEET MTLSCREWS AT 6"oc EW
MTL ROOF DECK
12" SQ < 4"Ø
24" SQ < 8"Ø
36" SQ < 12"Ø
WEB STIFF, SEE GSN
STL BMSTL BM
STL BMSTL BM
MTL ROOF DECK
MTL ROOF DECK
D1
S302
D1
S302
SEE EXT WALL CONNECTIONDETS FOR ADDITIONALREINF REQD
L
BENT PL (SEE TABLE)
< 6"
6" ≤ 10"
10" ≤ 12"
CLOSURE PL
3/16"
1/4"
5/16"
STL BM
L
1/2"
BM
3/8" BENT PL MAY BE USEDFOR OVERHANG < 16"
MTL ROOF DECKMTL ROOF DECK
UN
O
4"
PROVIDE 3/4" MIN GAP ATBRICK VENEER, CURTAINWALL OR STL STUD FRAMING.PROVIDE 1 1/4" MIN GAP APRECAST FRAMING
BYPASS FRAMING ASREQD, SEE ARCH DWGS
3/16 2-12TYP
STL BM
L
1/2"
STL BM
BM
NOTE: FOR ROOF EDGEOVERHANG GREATER THAN12", SEE DET
WEB STIFF, SEE GSN
MTL ROOF DECKMTL ROOF DECK
D1
S302
C1
S701
NOTE:ROOF DECK TO BE WELDEDTO ANGLE FRAME
L5x3x1/4 (LLV) x 0'-6" TYP
SEE FRAMING OPTION FORALT FRAMING
TRIM VERT LEGAT JST
FRAMING OPTION
SEE TYP ROOF TOP MECH UNIT SUPPORTDET FOR FRAMES BENEATHMECH UNITS WEIGHING MORE THEN 700#
PROVIDE EXTRA WEB MEMBERS PER(C3/S701) FOR OPNGS 6'-0" AND LARGER
OPEN WEB STL JST OR BM
SEE DET (B1/S701) FOROPNGS LESS THAN 12" IN Ø
SEE ARCH/MECH
OPNG DIM
ANGLE FRAMEL5x3x1/4 (LLV)
SEE
ARC
H/M
ECH
OPN
G D
IM
3/16TYP
3/16
3/16TYP
1/4
/(C4 S701)
UNIT PARALLEL TO JSTS PLAN VIEW
SECTION A-A
C12x30 BLW LONG SIDEOF CURB
L4x4x1/4 BLW DECK VERTLEG DOWN
C12x30 BLW LONG SIDEOF CURB
REMOVE DECK ATPEN ONLY C12x30 AT
6'-0"oc MAX
REMOVE DECK ATPEN ONLY
ROOF JST
DECK NOT SHOWN FORCLARITY
ROOF JST
RTU - CURB
TAPERED BLK
CHANNEL, LOCATE INDECK FLUTES ASSHOWN
RTU
NOTE: ACTUALCONFIGURATION OFFRAME TO SUPPORTMECH UNIT TO BESUPPLIED BY THE MECHENGINEER
1. INSTALL CHANNEL FROM TOP SIDE ABOVE DECK, LOCATE INDECK FLUTES ADJUSTING SPACING IN 6" INCREMENTS TOSUPPORT LONG SIDE OF CURB.
2. POSITION CURB OVER CHANNELS AND LOCATE REQUIRED DUCTPENETRATIONS THRU ROOF. REFER TO MECHANICAL PLANS FOREXACT SIZES AND LOCATIONS.
3. POSITION ANGLES BELOW DECK AND WELD TO CHANNELSTHRU DECK FROM TOP SIDE. OMIT CROSS ANGLES IF EDGES OFPENETRATION IS WITHIN 6" OF A JOIST.
4. CUT ROOF DECK ONLY AS REQUIRED FOR DUCT PENETRATIONS.
MECHANICAL UNIT SUPPORT NOTES
UNIT PERPENDICULAR TO JSTS PLAN VIEW
1/8THRU DECK
1/8THRU DECK
1/8THRU DECK, TYP
TRIM HORIZ LEG OF ANGLEWHERE UNIT SPANS OVERMORE THAN 2 JSTS
SOLID BLK THE FLUTES OF THE STL DECK BENEATH THE CURB OF THE MECH UNIT W/ HSS11/2x1 1/2x3/16x 0'-6", TACK WELDED TO THE STL DECK OR W/ SOLID BLK CONNECTED TO THESTL DECK
OPEN WEB STL JSTOR BM
SEE ARCH/MECH
CURB DIM
OPN
G F
OR
DU
CT
SEE
ARC
H/M
ECH
NOTE:ROOF DECK TO BE WELDEDTO ANGLE FRAME
6" M
IN
BEYOND JST TOP CHORD PANELPOINT COORD W/ JST SUPPLIER
L6x4x5/16 (LLV) TYP
L3X3x1/4 AROUND DUCTOPNG TYP
ANGLE FRAMEL6x4x5/16 (LLV) UNDER MECHUNIT CURBING
6" M
IN
BEYOND JST TOP CHORD PANELPOINT COORD W/ JST SUPPLIER
STL JST
3/16TYP
3/16 3-12TYP
2" MIN1/4"x3" PL
HANGER BY SUPPLIER
MTL ROOF DECK
60 lb MAXIMUM PERFLUTE (ONE POINTLOAD PER BAY)
HANGER BY SUPPLIER
MTL ROOF DECK
30 lb MAXIMUM PERFLUTE (ONE POINTLOAD PER BAY)
60 lb MAXIMUM PERFLUTE (ONE POINTLOAD PER BAY)
15 lb MAXIMUM PERFLUTE (ONE POINTLOAD PER BAY)
1/4"x1 1/2"x1 1/2"PL WASHER
MTL ROOF DECK
(2) #8 SELF DRILLINGSCREWS, TYP
L3x3x1/4
MTL ROOF DECK
12 ga x 3" WIDE STL STRAP
(MINIMUM 20 GAUGE DECK)(SUSPENDED LOADS FROM ROOF DECK ARE NOT PERMITTED FOR DECK
SPANS GREATER THAN 7'-0" AND SINGLE SPANS GREATER THAN 6'-0")
BAY IS DEFINED AS AN AREABETWEEN BEAMS OR JOISTS
(2) #8 SELF DRILLINGSCREWS, TYP
HANGER BY SUPPLIER
HANGER BY SUPPLIER
CANTILEVERED FLR BMSTL BM
(3) 7/8"Ø ERECTION BOLTS TYP
1/2" SHEAR TAB, TYP
WELD ACCESS HOLE,TYP
STL BM
5/16W/ 1" RETURN TYP
CJP, TYP
50 KSI WEB PL = BM WEBTHICKNESS + 1/8" W/ (3) 7/8" ØERECTION BOLTS (TYP)
BM BRG PL AS FOLLOWS:W8 - W10 3/4"x5 1/2" x 1'-0"W12 - W14 3/4"x5 1/2" x 1'-0"W16 - W18 3/4"x5 1/2" x 1'-0"W21 - W24 3/4"x5 1/2" x 1'-8"ALL PLS WITH (2) 3/4"øx 0'-10" HSA AT 10" GA
BRG PL 3/4" x 5 1/2" x 1'-0" W/ (2)3/4"ø x10" HSAAT 8" GA
BRG PL 3/4"xWALLTHICKNESS x 1'-0"W/(2) 3/4"ø x 0'-10" HSAAT 8" GA
BM BRG PL AS FOLLOWS:W8 & W10 - PL 1'-0" x 3/4"
x WALL THICKNESSW12 & W14 - PL 1'-0"x3/4"
x WALL THICKNESSW16 & W18 - PL 1'-0"x3/4"
x WALL THICKNESSW21 & W24 - PL 1'-0"x3/4"
x WALL THICKNESSALL PLS W/ (2) 3/4"ø x 8"HSA AT 10" GA
ST JST
1/2" JOINT WHEREOCCURS
MAS WALL
STL BM STL BM
ST JST
3 1/2"
5" TYP
3 1/2"
5" TYP1/2" TYP
MAS WALL
(1) #5 CONT BAR AT DB
(2) #5 CONT BARS AT JSTBRG
BTWN JSTS
DB L5x3x1/4 x CONT (LLH)PARALLEL TO DECK FLUTES
EMBED PL 3/8"x4" x 0'-8" W/ (2)3/4"x5" HSA AT 32"oc ((2) MINBTWN JSTS)
BRG PL
MTL ROOF DECK
GROUT JST POCKET SOLIDAFTER JST HAS BEENINSTALLED
3 1/2"STL JST
S701
A1 TYP
1/4
1/4
2
2TYP
3/16TYP
3/16
3/16TYP
MTL ROOF DECK
HORIZ BRDG BY JST SUPPLIER
DB ANGLEL3x3x1/4 x CONT PERP TODECK FLUTES
(2) #5 CONT BAR DB
MAS WALL
BRDG ATTACHMENTL3x3x1/4 x JST DEPTH W/ (2)3/4"Ø EPOXY BOLTS W/ 5"EMBED
EMBED PL 3/8"x4" x 0'-8" W/ (2)3/4"x5" HSA AT 5" GA AT 32"oc ((2)MIN BTWN JSTS)
NOTES:1. PER 'SJI' REQD BOTT HORIZ BRIDG SHALL
NOT KICK UP AT A DIAGONAL TOWARDSDECK BRG, BUT SHALL BE INSTALLED HORIZAS SHOWN.
2. DO NOT WELD BRDG TO WEB MEMBERS.3. DO NOT HANG ANY MECH, ELEC, ETC. EQUIP
FROM BRDG.
3/16TYP
3/16
3/16TYP
AT SIM: PROVIDE L5x3x1/4 x CONT (LLV) W/3/4" EPOXY BOLTS AT 24" oc W/ 5"EMBEDMENT INTO (E) CMU WALL
TYP DECK BRG ANGLE
JST BRG END
PL1/2"x5"x0'-8" W/ 3/4"ø x 0'-8"HSA EA SIDE OF MAS CJ
RUN HORIZ WALL REINFCONT THRU MAS CJ
MAS WALL
6" 6"
MAS CJ (MCJ)
SEE ARCH
1/4 4TYP
MTL ROOF DECK
HORIZ BRDG BY JST SUPPLIER
(2) #5 CONT BAR DB
MAS WALL
NOTES:1. PER 'SJI' REQD BOTT HORIZ BRIDG SHALL
NOT KICK UP AT A DIAGONAL TOWARDSDECK BRG, BUT SHALL BE INSTALLED HORIZAS SHOWN.
2. DO NOT WELD BRDG TO WEB MEMBERS.3. DO NOT HANG ANY MECH, ELEC, ETC. EQUIP
FROM BRDG.
PL 1/4"x5" x CONT W/3/4"Ø x 5" HSA AT 32"oc
BRDG ATTACHMENT L3x3x1/4 xJST DEPTH W/ (2) 3/4"Ø THRUBOLTS
3/16TYP
6"
6"
P = CONCENTRATED LOAD
ADDITIONAL DIAGONAL WEBMEMBER, L2x2x3/16 MIN
TYP ROOF JST
P = CONCENTRATED LOAD
NOTE:WHERE CONCENTRATED LOADS ON OPEN WEB JSTS ARE LOCATED MORE THAN 6" FROM THEPANEL POINTS AT EITHER THE TOP OR BOTT CHORD, ADDITIONAL DIAGONAL WEB MEMBERSSHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AT THE LOCATION OF THECONCENTRATED LOAD
3/16TYP
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:10:0
2 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
Author09.09.2016
16073
ROOF
FRAMING
DETAILS
S701
09.09.2016PERMIT SET
NO SCALE:S701
C4 HANGING MECHANICAL UNIT
NO SCALE:S701
B1TYPICAL PIPE SLEEVE HOLE DETAIL (12"Ø OR LESS) THRUROOF DECK
NO SCALE:S701
B2 TYPICAL STEEL BEAM TO STEEL BEAM CONNECTION DETAILS
NO SCALE:S701
C1 TYPICAL CLOSURE PLATE (OVERHANG 'L' ≤ 12")NO SCALE:S701
C2 TYP ROOF EDGE CONDITION AT BEAM (OVERHANG 'L' ≤ 12")
NO SCALE:S701
D1TYPICAL ROOF OPENING OR MECHANICAL UNIT WEIGHINGLESS THAN 700#
NO SCALE:S701
D3TYPICAL ROOF OPENING OR MECHANICAL UNITS (PLANVIEW)
NO SCALE:S701
D2TYPICAL ROOF TOP MECHANICAL UNIT WEIGHING MORETHAN 700#
NO SCALE:S701
B4 SUSPENDED LOADS FROM METAL DECKNO SCALE:S701
B3 TYPICAL CANTILEVER BEAM CONNECTION AT BEAM
NO SCALE:S701
A1 BEARING PLATE SCHEDULE FOR ROOF JOIST/BEAMNO SCALE:S701
A2 TYPICAL JOIST / DECK BEARING DETAILNO SCALE:S701
A3 TYPICAL DECK BEARING WITH BRIDGING DETAILNO SCALE:S701
A4 JOIST BEARING AT MASONRY CONTROL JOINT DETAIL
NO SCALE:S701
B6TYPICAL DECK BEARING AT MASONRY WALL WITHBRIDGING ATTACHMENT
NO SCALE:S701
C3 TYPICAL JOIST REINFORCING
# Date Revision
A A
A A
A A
OPEN
OPEN
OPEN OPEN
OPEN OPEN
OPEN OPEN
MTL ROOF DECK
(2) #5 CONT BARS AT JST BRG
MAS WALL
BRG PL
BTWN JSTS
DB PL 1/4"x5"x CONT W/3/4"Ø x 0'-5" HSA AT 32"oc
ALT BTWN JSTS
12ga BENT PL OR EQ
STL JST
S701
A1 TYP
3 1/2"
4"
1/8 3-12TYP
1/4
1/4
2
2TYPMTL ROOF DECK
(2) #5 CONT BARS AT JST BRG
MAS WALL
BRG PL
BTWN JSTS
DB PL 1/4"x5"x CONT W/3/4"Ø x 0'-5" HSA AT 32"oc
EDGE ANGLE L5x3x1/4x CONT (LLH)
EDGE ANGLE L5x3x1/4 xCONT (LLH)
STL JST
S701
A1 TYP
3 1/2"
1/4
1/4
2
2TYP
3/16
1/8 3-12
MTL ROOF DECK
(2) #5 CONT BARS AT JST BRG
MAS WALL
BRG PL
BTWN JSTS
DB PL 1/4"x5"x CONT W/3/4"Ø x 0'-5" HSA AT 32"oc
ALT BTWN JSTS
12ga BENT PL OR EQ
STL JST STL JST
S701
A1 TYP
4"
1/4
1/4
2
2TYP
1/8 3-12TYP
MTL ROOF DECK
WALL PARALLEL TO DECK FLUTES
MTL ROOF DECK
WALL PERPENDICULAR TO DECK FLUTES
(2) #4 CONT BAR AT DB
PL 3/8"x6"x CONT W/ 3/4"Ø x6" HSA AT 32"oc
PL 3/8"x5"x CONT W/ 3/4"Ø x 6"HSA AT 32"oc
(2) #4 CONT BAR AT DB
MAS WALL
MAS WALL
MTL ROOF DECK
STL JST
HSS4x6x1/4 POST
HSS BM
L3x3x1/4 x CONT, RADIUS TOMATCH ROOF
MTL ROOF DECK
STL BM
3/16
1/4
BTWN JSTS
STL BM
HSS5x5x3/16
2-12
2-12
C1
S701
CJP
CJP TOP &BOTT FLGS
TYP
CJP TOP & BOTT HSSTO PL, TYP
STL COL, SEE PLAN
STL BM, SEE PLAN
CONTINUITY PL (50ksi) THICKNESS =GREATER BM FLANGE + 1/8"
(3) ERECTION BOLTS
1/2" SHEAR TAB
W/ 1" RETURN5/16
HSS TO MATCH COL SIZE
CAP PL (50ksi) THICKNESS =GREATER BM FLANGE + 1/8"
(3) #5 CONT BARS x 4'-0"MIN AT BM BRG
MTL ROOF DECK
TYP HORIZ REINF AT TOP OFWALL
MAS COLGROUT BM POCKET SOLIDAFTER BM HAS BEENINSTALLED
STL BM
BRG PL
(1) #5 CONT BAR AT DB
BTWN BMS
DB L5x3x1/4 x CONT (LLH)PARALLEL TO DECK FLUTES
EMBED PL 3/8"x4" x 0'-8" W/ (2)3/4"x5" HSA AT 32"oc ((2) MINBTWN BMS)
BM WEB STIFF, EA SIDE,SEE GSN
S701
A1 TYP
3 1/2"
3/16
3/16TYP
1/4
1/4
4
4TYP
5" M
AX
OF
BOLT
3" T
O C
L
(E) MAS WALL
L4x4x3/8x8" W/ 3/4"ØBOLT AT 32"oc
HSS HEADER, SEE PLAN
1/8"xCONTx6" WIDE CLOSURE PL
1" MIN OVERLAP
3/4"Ø THRU BOLTAT 18"oc
L8x4x1/2xCONT EA SIDE. SEEDETAIL FOR EXTENDEDLENGTH BEYOND JAMBS AT EASIDE
(E) CMU TO BE SOLID GROUTED (4)FULL COURSES ABOVE OPENING
4"x4"x3/16" PL WASHERAT EA BOLT
5-16 3-12
5/16 3-12
1/8 312
/(C4 S702)
4"
TOS = (DB)-1'-0"
START ANGLES 4"BLW TOP OF COL
L4x4x3/8x0'-8" EA SIDE W/ 3/4"ØTHRU BOLT W/ 4" PLx3/16 WASHERON BACK SIDE. PROVIDE ANGLESAT 32"oc FOR FULL HEIGHT OF COL
EXTEND DBL ANGLE AS SHOWNIN DET 2'-0" PASTEDGE OF NEW OPENING IN CMUWALL
L8x8x1/2x0'-6" BEARINGSEAT W/ 3/8" GUSSET
ARCH
SEE
2'-0"
EDGE OF NEW OPENINGIN CMU WALL
STL ANGLE INSTALLEDPER
L4x4x1/4x0'-6"
HSS JAMB COL, SEE PLAN
1/4" CAP PL
5/16
1/43 SIDES
C3
S702
/(C3 S702)
/(C3 S702)
CEILING ELEV
SEE ARCH
1'-0
"
PORTION OF (E) WALL TO BE REMOVED
L6x3x3/8xCONT (LLV) W/ 3/4"ØTHRU BOLT AT 16"oc. EXTENDANGLES 16" BEYOND EAEDGE OF OPENING
PL 1/8"x4"xCONT1/8 3-12
2"EQ
EQEQ
2"
3" 6" 3" L (MIN)
RETURN MAS WALL
EMBED PL AT EA END OF BM3/4"x12"x2'-0" W/ (6) 3/4"Ø x 5"HSA'S CENTERED ON BM
MAS WALL
3/8" STIFFPL, TYP
STL BM
HSA AT BACK OFEMBED PL, TYP
L5x5x3/8 x 0'-10" TOP AND BOTT
5/16(3) SIDES, TYP
5/16
TYP AT EA END OFBM/WALL
D1
S302
A1
S701
'L'
SECTION A-A
JST TOP CHORD
L3x3x1/4 x 0'-6", TYP
L3x3x1/4, TYP
FRAMING OPTION
TRIM VERT LEG ATJST
JST TOP CHORD
L3x3x1/4 x 0'-6", TYP
L3x3x1/4, TYP
JST TOP CHORD
L3x3x1/4 x 0'-6" TYP
L3x3x1/4 TYP
SEE FRAMING OPTION FOR ALTFRAMING
DECK LEDGER ANGLE
L3x3x1/4 x 0'-6" TYP
L3x3x1/4 TYP
SEE FRAMING OPTION FORALT FRAMING
STRUCT WALL
TRIM VERT LEG TYP ATLEDGER
3/16TYP
3/16TYP
3/16TYP
3/16TYP
3/16TYP
3/16TYP
3/16TYP
3/16TYP
3/16TYP
3/16TYP
S702
C2 TYP
S702
C2 TYPOPP
OPP
MAS WALL
HSS BMS701
A1 TYP
MTL ROOF DECK
EDGE ANGLE
PROVIDE 3/8"THICK CAP PL
PROVIDE 3/8"THICK CAP PL
HSS POST
HSS BM
3/16
3/16BM TO BM
HSS BM
3/16
3/16BM TO POST
3/16TYP
HSS BM
HSS BM SKEWED
HSS POST
HSS BM
MTL ROOF DECK
EDGE ANGLE
3/8" CAPPL
3/16
3/16TYP
3/16
3/16TYP
1/4
HSS BM SKEWED
HSS COL
MTL ROOF DECK
HSS BM
3/16
3/16
3/16
3/16
3/16
3/16
EDGE ANGLE
(E) MAS WALL
MTL ROOF DECK
HSS BM
EDGE ANGLE
3/8" CAP PL
(E) MAS WALL
GROUTED CELLS IF NOTPREVIOUSLY GROUTED
3/16
PLUG WELD A36RODS TO PL1/2" x 9" SQ PL
(4) 3/4"Ø A36 THREADED RODSDRILLED AND EPOXIED W/ 5"EMBED 6" SQ SPACING
MTL ROOF DECK(E) MAS WALL
GROUT CELL
BTWN BMS
L4x4x1/4 DECK BRG ANGLE3/4"Ø A36 ALL THREAD RODW/ 5" EMBED, SPACE AT32"oc MAX AND 8" MAXFROM ENDS
SEE
ARCH
#5 AT 48"oc HORIZ
(2) #4 AT 32"oc VERT
1/2" DBA x 24" TO LAP W/ WALL VERTS
WEB STIFF 32"oc EA SIDE
STL BM
L5x3x1/4 (LLH) x CONT
MTL ROOF DECK
MAS WALL
1/4
1/4TYP
1 2 3 4 5
A
B
C
D
Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, Utah 84109T 801.924.5000http://www.archnexus.com
Original drawings remain the property ofthe Architect and as such the Architectretains total ownership and control. Thedesign represented by these drawings issold to the client for a one time use,unless otherwise agreed upon in writingby the Architect.© Architectural Nexus, Inc. 2014
NEXUS PROJECT #:CHECKED BY:DRAWN BY:DATE:
TAK
E
6
DIMENSIONS AND ELEVATIONS, AS THEY RELATE TO THEBUILDING IN GENERAL, i.e. GRID TO GRID DIMENSIONS ORDECK BEARING ELEVATIONS, ARE SUPPLIED BY THEARCHITECT. THEY ARE PROVIDED ON THE STRUCTURALPLANS AND DETAILS FOR THE CONVENIENCE OF THECONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONSWITH ARCHITECTURAL DRAWINGS.
NOTE:THESE STRUCTURAL DRAWINGS ARE BASED ONARCHITECTURAL DRAWINGS DATED 08.16.2016
This
dra
win
g, a
s an
inst
rum
ent o
f pro
fess
iona
l ser
vice
, is
the
prop
erty
of D
UN
N A
SSO
CIA
TES
INC
, and
sha
ll no
t be
used
, in
who
le o
r par
t for
any
oth
er p
roje
ct w
ithou
t the
writ
ten
perm
issi
on o
f an
auth
oriz
ed re
pres
enta
tive
of D
UN
N A
SSO
CIA
TES
INC
. Una
utho
rized
use
will
be p
rose
cute
d to
the
fulle
st e
xten
t of t
he la
w. C
opyr
ight
© 2
016
by D
UN
N A
SSO
CIA
TES
INC
.
9/9
/2016 4
:10:0
5 P
M
MU
RR
AY
CIT
Y
MU
RR
AY
PA
RK
AM
PH
I TH
EA
TE
R495 E
5300 S
PERMIT SET
Author09.09.2016
16073
ROOF
FRAMING
DETAILS
S702
09.09.2016PERMIT SET
NO SCALE:S702
D2 TYPICAL JOIST / DECK BEARING DETAILNO SCALE:S702
D1 TYPICAL JOIST / DECK BEARING DETAILNO SCALE:S702
D3 TYPICAL JOIST / DECK BEARING DETAILNO SCALE:S702
D4 TYPICAL DECK BEARING AT MASONRY WALLNO SCALE:S702
D6 TYPICAL JOIST TO STEEL BEAM CONNECTION
NO SCALE:S702
C1 BEAM TO HSS COLUMN MOMENT CONNECTION
# Date Revision
NO SCALE:S702
C2 TYPICAL BEAM / DECK BEARING DETAILNO SCALE:S702
C3 HSS HEADER DETAIL AT EXISTING CMUNO SCALE:S702
C4 TUBE STEEL JAMB/COLUMN AT NEW CMU OPENINGNO SCALE:S702
C5 TYPICAL INTERIOR OPENING IN CMU WALL DETAIL
NO SCALE:S702
B1 STEEL CHANNEL CANTILEVERED THRU MASONRY WALL
WEBSTIFF
NO SCALE:S702
B2 TYPICAL ROOF DRAIN SUPPORT (PLAN VIEW)NO SCALE:S702
B5 CANOPY DETAILNO SCALE:S702
B6 CANOPY DETAIL
NO SCALE:S702
A1 CANOPY DETAILNO SCALE:S702
A2 CANOPY AT EXISTING WALLNO SCALE:S702
A3 MASONRY PARAPET DETAIL