general model ba11 specifications active junction box

6
Model BA11 Active Junction Box General Specifications Sensors Cables Fittings Transmitters System configuration GS 12B06W03-01E-E Edition 4 Accessories General The BA11 Active Junction Box is designed for a wide range of industrial environments and is tested against the latest standards. The model BA11 Active Junction Box has the ability to connect multiple Yokogawa SA11 smart adapters, acting as slave devices, to a host system using one trunk connection, resulting in a cost- effective solution. The BA11 Active Junction Box automatically senses a (dis) connected smart adapter, and as a result, switches the 120 Ω line termination for keeping the RS-485 communication balanced. This way, a plug and play solution is provided without the need for manually placed terminating resistors. Features • Auto balancing of RS-485 digital bus • Star topology for connecting multiple (maximum 4) Yokogawa smart adapters. • Indoor- and outdoor application • Application in industrial environments • Wall- and pipe mounting options • NEMA 4X protection (only in combination with option /UM) • General purpose and Non-Incendive version

Upload: others

Post on 21-Nov-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: General Model BA11 Specifications Active Junction Box

Model BA11 Active Junction Box

GeneralSpecifications

Sensors Cables Fittings Transmitters Accessories

System configuration

GS 12B06W03-01E-EEdition 4

Sensors Cables Fittings Transmitters Accessories

General The BA11 Active Junction Box is designed for a wide range of industrial environments and is tested against the latest standards.The model BA11 Active Junction Box has the ability to connect multiple Yokogawa SA11 smart adapters, acting as slave devices, to a host system using one trunk connection, resulting in a cost-effective solution.

The BA11 Active Junction Box automatically senses a (dis)connected smart adapter, and as a result, switches the 120 Ω line termination for keeping the RS-485 communication balanced. This way, a plug and play solution is provided without the need for manually placed terminating resistors.

Features • Auto balancing of RS-485 digital bus • Star topology for connecting multiple (maximum 4) Yokogawa

smart adapters. • Indoor- and outdoor application• Application in industrial environments• Wall- and pipe mounting options• NEMA 4X protection (only in combination with option /UM)• General purpose and Non-Incendive version

Page 2: General Model BA11 Specifications Active Junction Box

2

GS12B06W03-01-E-E

General specifications

1. Basic Architecture : An epoxy coated aluminium die cast

housing provided with connection system for host system and Yokogawa smart adapters. Interconnection cables to be used are model WU11 connection/extension cable, which can be provided in different length up to maximum 100 meter (328ft). The housing can be mounted on a wall, pipe or at the backside of a FLXA402 analyzer using the optional universal mounting set (see section 8).

2. Electrical Power supply Operating* : +2.7 VDC to +5.5 VDC / 30mW avg. Input/Output : Bi-directional digital communication

(RS485) with auto balancing of bus termination (120Ω).

Note: Total power consumption depends on number of Field Devices and the amount of Modbus registers read from individual Field Device in time

3. Mechanical and others Housing Material : Aluminum die cast with epoxy coating Size (LxWxH) : 154 x 64 x 34 mm (5.9x2.5x1.3”) Color : Grey (RAL 7001) IP classification : IP66 (acc. ANSI/IEC 60529:2004;

C22.2 No. 60529:2016) NEMA classification : Type 4X (acc. NEMA 250:2014;

ANSI/UL 50E:2015) Sealing : Neoprene Applicable torque : on cover screw (to meet IP66)

Min. 1.1 Nm - Max. 2.5 Nm Connectors : 5-pins male connector (BUS IN)

for connection to host system and 5-pins female connectors (J1 ~ J4) for connection to smart adapters. The 5-pins female connector (BUS OUT) is for serial connection of BA11 devices.

Material : Nickel-plated brass Insulation : Polybutylene terephthalate (PBT) Contacts : Gold-plated Sealing : Male connector: EPDM; Female

connector: NBR, EPDM Applicable torque : on BA11 connector screws and

protection caps (to meet IP66) 0.25 Nm For connection method and maximum allowed cable length

in a Class I, DIV 2 location, then refer to the enclosed Control Drawing D&E 2019-012-A60.

Labeling : Ink printing combined with adhesive metallized stickers.

Weight : Approximately: 350 gr.

Ambient operating conditions Temperature : -20°C to +55°C (-5°F to +130°F) Humidity : 93% at +40°C (+100ºF),

non-condensing

Storage conditions Temperature : -30°C to +70°C (-20°F to +160°F)

4. Regulatory standards

Non-IncendiveFM-United States Non-Incendive for Class I, Division

2, Groups A, B, C & D Hazardous (Classified) Location,

Indoors/Outdoors with a Temperature code T6/T5/T4 for -20°C ≤ Ta ≤ +55°C when connected in accordance with Control Drawing D&E 2019-012-A60.

By applying: : FM3600: 2018 Electrical Equipment for

Use in Hazardous (Classified) Locations, General Requirements

: FM3611: 2018 Non-Incendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Divisions 1 and 2, Hazardous (Classified) Locations

: FM3810: 2018 Electrical and Electronic Test, Measuring and Process Control Equipment

: UL 121201: 2017 Non-Incendive Electrical Equipment for Use in Class I and II, Division 2, and Class III, Divisions 1 and 2, Hazardous (Classified) Locations

: ANSI/ISA 61010.1: 2012 Safety requirements for electrical equipment for measurement, control and laboratory use – Part 1: General requirements

Certificate no.: FM19US0166X. For Specific conditions of Use refer to section 5.

FM-Canada Non-Incendive for Class I, Division 2, Groups A, B, C & D Hazardous (Classified) Location,

Indoors/Outdoors with a Temperature code T6/T5/T4 for -20°C ≤ Ta ≤ +55°C when connected in accordance with Control Drawing D&E 2019-012-A60.

By applying: : CSA-C22.2 No. 0.4: R2013 Bonding of

Electrical Equipment : CSA-C22.2 No. 213: 2017 Non-

Incendive Electrical Equipment for Use in Class I, Division 2, Hazardous Locations

: C 22.2 No. 61010.1: 2012 Safety requirements for electrical equipment for measurement, control and laboratory use – Part 1: General requirements

: C22.2 No. 94.2: 2015 Enclosures for Electrical Equipment, Environmental Considerations

Certificate no.: FM19CA0089X. For Specific conditions of Use refer to section 5

Page 3: General Model BA11 Specifications Active Junction Box

3

GS12B06W03-01E-E

CE By applying: (768/2008/EC) - EN-ISO 9001: 2008.

• EMC Directive By applying: (2014/30/EU) - IEC 61326-1:2012 Electrical equipment

for measurement, control and laboratory use – EMC requirements – Part 1: General requirements. Emission: Class B, control and laboratory use.

Immunity: For use in industrial locations. - EN 61326-1:2013 Electrical equipment

for measurement, control and laboratory use – EMC requirements – Part 1: General requirements. Emission: Class B, control and laboratory use. Immunity: For use in industrial locations.

- CISPR 11:2015 Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics Limits and methods of measurement. Emission: Radiated emission up to 1 GHz (SAC).

- EN 55011:2016 + A1:2017 Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics Limits and methods of measurement. Emission: Radiated emission up to 1 GHz (SAC).

• LVD Directive By applying: (2014/35/EU) - IEC/EN 61010-1:2010 Safety requirements

for electrical equipment for measurement, control and laboratory use.

- IEC 61010-2-030:2017 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for testing and measuring circuits.

- EN 61010-2-030:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for testing and measuring circuits.

- IEC 60529:1989 + A1:1999 + A2:2013 Degrees of protection provided by enclosures (IP Code).

- EN 60529:1991 + A1:2000 + A2:2013 Degrees of protection provided by enclosures (IP Code).

• RoHS 2 Directive By applying: (2011/65/EU) - EN 50581:2012 and IEC 50581:2012

Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances

Compliancy - AS/NZS CISPR 11 - KC Registration of broadcasting and

communication equipment KCC-R-R-YPA-BA11

Recommendations and guidelines

NAMUR Precompliance checked by applying: - NAMUR NE21: 2017 Electromagnetic

compatibility (EMC) of industrial process and laboratory.

5. Specific Conditions of Use

If the BA11 product is not installed using Non-Incendive Field Wiring, then the BA11 product shall be installed in compliance with the enclosure, mounting, spacing and segregation requirements of the ultimate application, including a tool removable cover.To maintain the IP66 rating, the BA11 product shall be installed using the WU11 cables or the original connector caps supplied with the BA11 product.

To maintain the Type 4X rating, the BA11 product shall be installed using the WU11 cables or the original connector caps supplied with the BA11 product, and the BA11 product shall be installed using the tool secured, NEMA 4X identified mounting bracket which is part of option UM.

6. Model & Suffix Codes

Model Suffix Option DescriptionCode Code CodeBA11 Active Junction BoxMaterial -C Aluminium alloy, epoxy coatingType -AA General purpose -DD NI (Non-Incendive) for

FM-United States/FM-CanadaConn. type -M9 M9 male/female connectors, 5pOptions /UM Universal mounting set

Page 4: General Model BA11 Specifications Active Junction Box

4

GS12B06W03-01-E-E

7. Control Drawing D&E 2019-012-A60

Non

-Haz

ardo

us L

ocat

ion

Clas

s I,

Div

. 2, G

P AB

CD, T

6/T5

/T4

HO

STPo

wer

para

met

ers:

Voc

I/O

Isc

Ca La

NIF

W P

aram

eter

s BA

11Vm

ax5.

5 V

Spec

ified

Voc

of t

he H

OST

sha

ll no

t exc

eed

the

Vmax

of t

he B

A11

or th

e Vm

ax o

f any

of t

he u

nit l

oads

Imax

517

mA

Spec

ified

Isc

of th

e H

OST

sha

ll no

t exc

eed

the

Imax

of t

he B

A11

or th

e Im

ax o

f any

of t

he u

nit l

oads

Ci1.

42 μF

Li0

mH

Sum

of L

IN, L

OU

T, L

1, L

2, L

3, L

4 ≤

250

mtr

. All

cabl

es m

ust b

e ty

pe W

U11

(Cca

ble

= 0.

2 nF

/mtr

., Lc

able

= 0

.1 μ

H/m

tr.)

Not

es: 1)

No

revi

sion

to th

is d

raw

ing

with

out p

rior a

ppro

val o

f FM

.2)

Inst

alla

tion

mus

t be

in a

ccor

danc

e w

ith th

e N

atio

nal E

lect

rical

Cod

e (A

NSI

/NFP

A 70

; CSA

C22

.1) a

nd re

leva

nt lo

cal c

odes

.3)

WAR

NIN

G -

EXPL

OSI

ON

HAZ

ARD

. DO

NO

T O

PEN

WH

ILE

THE

EQU

IPM

ENT

IS E

NER

GIZ

ED O

R W

HEN

AN

EXP

LOSI

VE A

TMO

SPH

ERE

IS P

RESE

NT.

AVER

TISS

EMEN

T - R

ISQ

UE

D'E

XPLO

SIO

N. N

E PA

S O

UVR

IR L

ORS

QU

E L'

ÉQU

IPM

ENT

EST

SOU

S TE

NSI

ON

OU

EN

PRÉ

SEN

CE D

ÚN

E AT

MO

SPH

ÈRE

EXPL

OSI

VE4)

WAR

NIN

G -

SUBS

TITU

TIO

N OF

COM

PON

ENTS

MAY

IMPA

IR S

UIT

ABIL

ITY FO

R D

IVIS

ION

2.

À L'

APTI

TUD

E À

LA

DIV

ISIO

N 2

.5)

Cabl

e co

nnec

tors

mus

t be

fully

eng

aged

usi

ng th

e po

sitio

ning

not

ch a

nd m

echa

nica

l ret

ensi

on.

6)Th

e BA

11 c

onne

ctor

s an

d pr

otec

tion

caps

mus

t be

secu

red

with

a to

rque

of 0

.25

Nm

. The

lid

scre

ws

mus

t be

secu

red

with

a to

rque

of 1

.1 N

m.

7)So

me

equi

pmen

t ide

ntifi

es in

terc

onne

ctio

n pa

ram

eter

s us

ing

term

inol

ogy

asso

ciat

ed w

ith th

e Zo

ne c

lass

ifica

tion

sche

me.

In s

uch

case

, not

e th

at th

e fo

llow

ing

term

s ar

e eq

uiva

lent

:

La

Uo Io Co Lo

Isc

Ca

BA11

#8

Term

inol

ogy

Div

isio

n sc

hem

e:Te

rmin

olog

y Zo

ne s

chem

e:Vo

c

HO

ST p

aram

eter

sTe

rmin

olog

y D

ivis

ion

sche

me:

VmaxBA

11 /

unit

load

par

amet

ers

Ui

Term

inol

ogy

Zone

sch

eme:

Ii Ci Li

BA11

#1BA

11#2

Imax Ci Li

L2

BUS

BU

S

IN

O

UT

J1

J2

J3

J4

unit

load

s1.

..4un

it lo

ads

5...8

unit

load

s29

...32

L L

OU

TL1

BUS

BU

S

IN

O

UT

J1

J2

J3

J4BU

S

BUS

IN

OU

T

J1

J2

J3

J4

L3L4

Sum

of C

i val

ues

for a

ll BA

11s

and

all u

nit l

oads

con

nect

ed, p

lus

the

sum

of a

ll as

soci

ated

cab

le c

apac

itanc

e sh

all n

ot e

xcee

d th

e sp

ecifi

ed C

a va

lue

of th

e H

OST

Sum

of L

i val

ues

for a

ll BA

11s

and

all u

nit l

oads

con

nect

ed, p

lus

the

sum

of a

ll as

soci

ated

cab

le in

duct

ance

sha

ll no

t exc

eed

the

spec

ified

La

valu

e of

the

HO

ST

AVER

TISS

EMEN

T - L

A SU

BSTI

TUTI

ON

DE

COM

POSA

NTS

PEU

T N

UIR

E

Page 5: General Model BA11 Specifications Active Junction Box

5

GS12B06W03-01E-E

8. Dimensions and Mounting

Figure 1. Dimensions BA11 Active Junction Box

24

2.

52

1.

34 34

5.43

1.

42

14

1.

1

1.42

2

Dimension in mm [inches]

Figure 3. BA11 with /UM (NEMA 4X bracket excluded)Figure 2. BA11 with /UM (NEMA 4X bracket included)

14.5

15

2

3.23

1.

1

3.31

Dimension in mm [inches]

Figure 4. Pipe mounting

Page 6: General Model BA11 Specifications Active Junction Box

Figure 6. Mounting at backside of FLXA402 analyzer

Figure 5. Wall mounting

15

14.5

11

2

1.

435

.5

11

Dimension in mm [inches]

3.15

11

2

2

Dimension in mm [inches]

GS 12B006W03-01E-ESubject to change without notice Printed in The Netherlands, 4-2102Copyright©

Dimension in mm [inches]

Yokogawa has an extensive sales and distribution network. Please refer to the European website (www.yokogawa.com/eu) to contact your nearest representative.

YOKOGAWA EUROPE BVEuroweg 23825 HD AMERSFOORTThe Netherlandswww.yokogawa.com/eu

YOKOGAWA ELECTRIC CORPORATIONWorld Headquarters9-32, Nakacho 2-chome, Musashino-shiTokyo 180-8750Japanwww.yokogawa.com

YOKOGAWA CORPORATION OF AMERICA2 Dart RoadNewnan GA 30265USAwww.yokogawa.com/us

YOKOGAWA ELECTRIC ASIA Pte. LTD.5 Bedok South RoadSingapore 469270Singaporewww.yokogawa.com/sg

YOKOGAWA CHINA CO. LTD.Room 1801, Tower B, THE PLACENo.100 Zunyi Road Changing District, Shanghai, Chinawww.yokogawa.com/cn

YOKOGAWA MIDDLE EAST B.S.C.(c)P.O. Box 10070, ManamaBuilding 577, Road 2516, Busaiteen 225Muharraq, Bahrainwww.yokogawa.com/bh

TYPE

O

F CERTIFICATIONMARK

ISO9001