general e vol.1
TRANSCRIPT
www.kaise.com
Vol.1GENERAL CATALOG
Electrical Measuring Instruments
7
7
7
8
8
8
8
9
9
9
10
10
10
11
11
11
12
12
12
12
14
14
14
14
14
15
15
15
15
15
15
18
18
18
19
19
19
20
20
20
22
22
22
24
25
25
25
26
26
27
27
27
28
29
30
SK-7660
SK-7661
SK-7682
SK-7718
SK-7719
SK-7720
SK-7722
SK-7706
SK-7707
SK-7708
SK-7600
SK-7602
SK-7603
SK-7615
SK-7625
SK-7640
SK-7810
SK-7815
SK-7820
SK-7825
SK-3500
SK-3502
SK-3000
SK-3002
SK-3003
SK-3010
SK-3012
SK-3013
SK-3016
SK-3320
SK-3710
KU-2602
SK-6161
SK-6163
SK-6150
SK-6500
SK-6555
SK-6592
SK-4033
SK-4035
SK-355
KF-32
KF-20
KT-2020
SK-6166
SK-6167
SK-8401
SK-7830
SK-8402
SK-8301
SK-6850
Temperature Probe
100-41 / 100-62 / 100-63 / 100-57792 / 793 / 944 / 946 / 795
940 / 810-02 / 818 / 818-02 / 880 / 821 / 660731 / 732 / Standard Accessories (excerption)
Other Testers
Accessories
Mark Descriptions
Contents
Digital Multimeters
Analog Multitesters
Clamp Meters
Insulation TestersEarth Tester
AC / DC Digital Clamp Meters
AC Digital Clamp Meters
AC Leakage Clamp Meters
Digital Insulation Testers
Analog Insulation Testers
Earth Tester
Handy-Type
Card-Type DMM
All-in-one DMM
Probe Tester
Bench-Top DMM
Drop-Proof Tester
Analog Multitesters
Digital Multimeters
Digital Tachometer
Low Current DC Clamp Meter
O2 Sensor Checker
Triaxial ELF Magnetic Field Meter
Digital Thermometer
Automotive Testers
2
Note the following WARNINGS and CAUTIONS when using Electric / Electronic Measuring Instruments.
Caution Symbol on the instrument indicates that the user should
read carefully the operating instructions in the manual.
High Voltage Warning Symbol on the instrument indicates that
a potential of 1000V or more high voltage may be present on the
Terminals. The user should use extreme care about safety practices.
Maximum Allowable Ground Voltage Symbol on the instrument
indicates that the maximum voltage between INPUT Terminals
and Earth Ground is 500V in this case. The user must not apply any
voltage that will exceed the maximum voltage.
Safety Symbols1
The ordinary multimeters, analog or digital, are provided with maximum range of
500V to 1000V AC and DC. But, most of them are designed to measure Low Power
Circuits such as TVs, Radios and home electrical apparatus.
Therefore, to measure High Power Circuits or High Power Line more than 220V, such
as Power Supplies for Factory Equipments and Facilities, etc., do NOT use any
ordinary multimeters. Use the instruments especially designed for High Power Line.
High Power Line sometimes includes Surge Voltage more than 10 times of the rated
voltage. So, the Surge Voltage will cause electric shock accidents when measuring
with the ordinary multimeters. Even if the circuit to be measured is of Low Power, if
the voltage is greater than 220V, use the instruments with great care observing
warnings and cautions written in the instruction manuals concerned.
Warnings for High Power Line andHigh Voltage Measurements
2
ISO 9001 : 2000 (Quality assurance)
ISO (International Organization for Standardization) is a global network that identifies
what International Standards are required by business, government and society,
develops them in partnership with the sectors that will put them to use, adopts them
by transparent procedures based on national input and delivers them to be implemented
worldwide.
KAISE CORPORATION has been assessed to comply with the requirements of the
following Quality Management System Standard.
ISO 9001 : 2000 JIS Q 9001 : 2000
Design and Development, Manufacture and Servicing of Electric and Electronic Measuring
Instruments.
Registration Date : 1st October 2005 Original Registration : 1st October 1999
CE Mark
CE marking is a safety mark which can be attached only on a
product meeting the safety requirements of the Directive of Council
of the European Union (EC Directive).
A product attached with the CE mark is designed so as to meet the
requirements of the "Low Voltage Directive" and "EMC Directive" of the EC Directive.
Low Voltage Directive: This Directive covers products of power supply voltage of
50V-1000V(AC) and 75V-1500V(DC), and it defines electric safety requirements against
shocks, burns, etc. The applicable standard is EN61010 corresponding to IEC1010
give on the left. EMC Directive: This Directive stipulates conditions so as not to give
out strong electromagnetic waves from equipment to the outer environment and to
protect equipment from the effect of electromagnetic waves from the outside.
Traceability Chart
Traceability to prove the compliance with national and international standards is an essential factor for measuring instruments used as test instruments associated with quality
assurance. Products of Kaise are calibrated by reference samples which is periodically checked for its compliance with national standards. A calibration certificate and test data
report are available on your request.
AC/DC Voltage
Measuring Instruments in R&D, Production, Inspection and Service Department
Comparative Standards
Resistance Frequency
LCR Meter Digital thermohygrometer Micrometer / Slide Caliper Current ShuntHigh-Accuracy Digital Multimeter
Capacitance Temperature Humidity Length AC/DC Current
National Standards
Calibration Standards
Applied Standards
Calibrated Parameters
National Institute of AdvancedIndustrial Science and Technology
AISTNational Institute of Informationand Communications Technology
NICTNational Institute of Standardsand Technology
NISTJapan Electric Meters InspectionCorporation
JEMIC
Higher-numbered categories correspond to electrical environments with greater momentary energy, so a measurement product designed for CAT Ⅲ environments can endure
greater momentary energy than one designed for CATⅡ. Using a measurement product in an environment designated with a higher-numbered category than that for which the
product is rated rated could result in a severe accident, and must be carefully avoided.
Never use a CATⅠmeasuring product in CATⅡ, Ⅲ, or Ⅳ environments.
The measurement categories comply with the Overvoltage Categories of the IEC60664 Standards.
For Safety
The International Safety Standard IEC61010To ensure safe operation of measurement products, IEC 61010 establishes safety
standards for various electrical environments, categorized as CATⅠto CAT Ⅳ, and
called measurement categories. These are defined as follows.
CAT.ⅠSecondary electrical circuits connected to an AC electrical outlet through a
transformer or similar device.
CAT.ⅡPrimary electrical circuits in equipment connected to an AC electrical outlet
by a power cord (portable tools, household appliances, etc)
CAT.ⅢPrimary electrical circuits of heavy equipment (fixed installations) connected directly
to the distribution panel, and feeders from the distribution panel to outlets.
CAT.ⅣThe circuit from the service drop to the service entrance, and to the power
meter and primary over current protection device (distribution panel).
Distribution board
CAT.Ⅳ
CAT.Ⅲ
CAT.Ⅱ
CAT.Ⅰ
Indoor wiring
Power receptaclePower receptacle
Service entrance
Watthour meter
Service wire
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
3
Clamp Meters Index
Model
Display Counts
Conductor Diameter
DC Current
AC Current
DC Voltage
AC Voltage
Resistance
Frequency
Duty Cycle
Pulse Width
Continuity Test
Diode Test
Capacitance
Temperature
True RMS
Auto Ranging
Manual Ranging
MAX / MIN
Average
Peak Hold
Range Hold
Difference
Display Hold
Power-On Initialize
Comparator
Low Pass Filter
Output Terminal
External Power Supply
Dust Proof & Simple Water Resistant
Auto Power Save (Off)
4000
φ27mm
40A
400A
-40A
400A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ
40kΩ400kΩ4MΩ40MΩ●●-●●●-●●---●-●●●*1
-----●
4000
φ27mm
40A
400A
-40A
400A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ
40kΩ400kΩ4MΩ40MΩ●●-●●●--●-●---●●●*1
-----●
4000
φ19mm
40A
400A
-40A
400A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
------●●-----●●-●-●-●●●*1
-----●
AC / DC Digital Clamp Meters
*1 : for DC Current measurement
4000
φ35mm
400A
1000A
-400A
1000A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ40kΩ
400kΩ4MΩ40MΩ●●-●●●-●●-●-●-●●●*1
----●●
SK-7718
4000
φ35mm
400A
1000A
-400A
1000A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ40kΩ
400kΩ4MΩ40MΩ●●-●●●--●-●--●●●●*1
----●●
4
Clamp Meters Index
Model
Display Counts
Conductor Diameter
DC Current
AC Current
DC Voltage
AC Voltage
Resistance
Frequency
Duty Cycle
Pulse Width
Continuity Test
Diode Test
Capacitance
Temperature
True RMS
Auto Ranging
Manual Ranging
MAX / MIN
Average
Peak Hold
Range Hold
Difference
Display Hold
Power-On Initialize
Comparator
Low Pass Filter
Output Terminal
External Power Supply
Dust Proof & Simple Water Resistant
Auto Power Save (Off)
4000
φ55mm
400A
2000A
-400A
2000A
--
40V
400V
600V
--
40V
400V
600V
-4kΩ40kΩ----●●●●●-●●●●●●●●●●---●●●●
4000
φ55mm
400A
2000A
-400A
2000A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ40kΩ
400kΩ4MΩ40MΩ●●-●●●--●●●--●●●●*1
----●●
SK-7707
4000
φ55mm
400A
2000A
-400A
2000A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ40kΩ
400kΩ4MΩ40MΩ●●-●●●-●●●●-●●●●●*1
----●●
SK-7708
AC / DC Digital Clamp Meters
*1 : for DC Current measurement
4000
φ36mm
400A
1000A
-400A
1000A
--
400V
650V
---
400V
650V
--
4000Ω20kΩ----●●●---●●●-●-●-●●-----●-
SK-7720
4000
φ36mm
400A
1000A
-400A
1000A
--
40V
250V
---
40V
250V
--
4000Ω20kΩ----●●●---●●●-●-●-●●---●●●-
SK-7722
Clam
p M
etersInsulation Testers / Earth Tester
Dig
ital Mu
ltimeters
An
alog
Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
5
Clamp Meters Index
Model
Display Counts
Conductor Diameter
DC Current
AC Current
DC Voltage
AC Voltage
Resistance
Frequency
Duty Cycle
Pulse Width
Continuity Test
Diode Test
Capacitance
Temperature
True RMS
Auto Ranging
Manual Ranging
MAX / MIN
Average
Peak Hold
Range Hold
Difference
Display Hold
Power-On Initialize
Comparator
Low Pass Filter
Output Terminal
External Power Supply
Dust Proof & Simple Water Resistant
Auto Power Save (Off)
4000
φ27mm
---
40A
200A
-------------------------●------●------●
4000
φ27mm
---
40A
400A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ
40kΩ400kΩ4MΩ40MΩ●●-●●●-●●-●---●●------●
4000
φ27mm
---
40A
400A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ40kΩ
400kΩ4MΩ
40MΩ●●-●●●--●-●---●●------●
2000
φ26mm
---2A
20A
200A
400A
200mV
2V
20V
200V
600V
2V
20V
200V
600V
200Ω2kΩ20kΩ
200kΩ2MΩ20MΩ---●●---●*2
------●------●
AC Digital Clamp Meters
*2 : Two-ranges auto for ACA.
2000
φ42mm
---2A
20A
200A
600A
200mV
2V
20V
200V
600V
2V
20V
200V
600V
200Ω2kΩ20kΩ
200kΩ2MΩ20MΩ---●●---●*2
------●------●
4000
φ55mm
---
400A
2000A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ40kΩ
400kΩ4MΩ40MΩ●●-●●●-●●●●--●●●-----●●
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
6
Clamp Meters Index
Model
Display Counts
Conductor Diameter
DC Current
AC Current
DC Voltage
AC Voltage
Resistance
Frequency
Duty Cycle
Pulse Width
Continuity Test
Diode Test
Capacitance
Temperature
True RMS
Auto Ranging
Manual Ranging
MAX / MIN
Average
Peak Hold
Range Hold
Difference
Display Hold
Power-On Initialize
Comparator
Low Pass Filter
Output Terminal
External Power Supply
Dust Proof & Simple Water Resistant
Auto Power Save (Off)
3200
φ30mm
---
30mA
300mA
60A
-------------------------●●----●-●●●--●
SK-7810
3200
φ30mm
---
30mA
300mA
30A
60A
-----
300V
600V
----------------●-●----●-●●---●
SK-7815
AC Leakage Clamp Meters
*3 : mA / A : switch selection
4000
φ24mm
---
40mA
400mA
40A
100A
-----
400V
600V
----------------●*3
------●-
●(with Vibration)
●---●
SK-7820
4000
φ40mm
---
40mA
400mA
40A
100A
-----
400V
600V
----------------●*3
------●-
●(with Vibration)
●---●
SK-7825
Clam
p M
etersInsulation Testers / Earth Tester
Dig
ital Mu
ltimeters
An
alog
Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
7
SK-7660
MAXM I N
PEAKHOLD
Handy-size Clamps with Efficient Functions
AC/DC
VAC/DC
400A
DIFF
DUTY
%HzΩ
FEATURES● 15 measurement functions in one small package.● "Power-On Initialize" (auto zero adjustment) in DCA.● Rubber-molded rotary switch and trigger.● Easy-to-clamp compact & beaked clamp head even
for narrow conductors.● True RMS and peak hold (SK-7660), MAX/MIN (SK-7661)
Accuracy±1.5%rdg±3dgt40 to 200A201 to 300A301 to 400A±1.5%rdg±5dgt (50/60Hz)40 to 200A201 to 300A301 to 400A±0.2%rdg±2dgt±1.0%rdg±3dgt
±1.0%rdg±2dgt
±1.5%rdg±5dgt (40 to 400Hz)
±0.2%rdg±2dgt
±1.0%rdg±3dgt±1.5%rdg±5dgt±0.7%rdg±3dgt±1.2%rdg±5dgt±3.0%rdg±5dgt±1.5%rdg±5dgt±5.0%rdg±5dgt
±1.5%rdg±5dgt±3.0%rdg±3dgt±4.0%rdg±3dgt
±2.0%rdg±3dgt (50/60Hz)±4.0%rdg±5dgt (50/60Hz)±5.0%rdg±5dgt (50/60Hz)
*Frequency Characteristic (40 to 400Hz) : 40A Range (0.5 to 9A) add 1.5% (10 to 40A) add 0.5% 400A Range add 1.0%
SK-7660 SK-7661
OPTIONAL ACCESSORIES880 Line Separator940 Alligator Clips793 Coil-Type Contact Pin
A / A Hz
V / VHz / %
Range40A
400A
40A
400A
5Hz to 1kHz400mV4V40V400V600V4V40V400V600V5Hz to 49.99kHz5% to 95%400Ω4kΩ40kΩ400kΩ4MΩ40MΩ
Continuity Test, Diode Test, Capacitance
Peak Hold (SK-7660), MAX / MIN (SK-7661), Difference, Power-on Initialize (for DC Current measurement),Display Hold, Auto Power OFF
for DC Currentmeasurement
AUTOZERO APODISP
HOLD
SK-7660
TRUERMS
Accuracy±1.5%rdg±3dgt40 to 200A201 to 400A±1.5%rdg±5dgt36 to 200A201 to 400A±1.0%rdg±3dgt
±1.0%rdg±2dgt
±1.5%rdg±5dgt
±2.0%rdg±3dgt±4.0%rdg±3dgt
±2.0%rdg±5dgt±5.0%rdg±5dgt
Range40A
400A
40A
400A
400mV4V40V400V600V4V40V400V600V
Frequency, Duty Cycle
MAX / MIN, Peak Hold, Difference,Power-on Initialize (for DC Current measurement),Display Hold, Auto Power Off
MAXM I N
PEAKHOLD
Focused on High-Flexibility
AC/DC
VAC/DC
400ADISPHOLDDIFF
HzTRUERMSAPO
DUTY
%for Voltagemeasurement
φ27mm
ConductorDiameter
φ19mm
ConductorDiameter
for DC Currentmeasurement
AUTOZERO
FEATURES●Usable for Automotive Measurements.● Peak Current and Peak Voltage.●Max / Min and Difference Measurements.
DCVoltage
ACVoltage
DCCurrent
ACCurrent*
Frequency
Frequency
Duty Cycle
Resistance
OtherMeasurements
Functions
DCVoltage
DCCurrent
ACCurrent
ACVoltage
OtherMeasurements
Functions
AC / DC Digital Clamp Meters
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 40503 times / secAuto Rangingφ27mm Max. 1.5V R03 or AAA Batteries (x 2)CATⅢ 300V, CATⅡ 600V and EMC 170(H) x 58(W) x 27(D)mm 160g100-63 Test Leads (x 1 set)1015 Carrying Case (x 1)1.5V R03 Batteries (x 2)
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 40503 times / sec Auto Rangingφ19mm Max. 1.5V R6P or AA Batteries (x 2) CATⅢ 300V and EMC196(H) x 59(W) x 30(D) mm180g100-57 Test Leads (x 1 set)940 Alligator Clips (x 1 set)1011 Carrying Case (x 1)1.5V R6P Batteries (x 2)
OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set793 Coil-Type Contact Pin
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
8
SK-7720
φ36mm
ConductorDiameter
Versatile Clamp Meter, Compactly Designed
SK-7718
Resistance
OtherMeasurements
Functions
Accuracy±1.5%rdg±5dgt400 to 600A601 to 1000A±1.5%rdg±3dgt400 to 600A601 to 1000A±0.2%rdg±2dgt
±1.0%rdg±5dgt (40Hz to 400Hz)
±1.0%rdg±3dgt
±0.2%rdg±2dgt
±2.0%rdg±2dgt±1.5%rdg±5dgt
±1.0%rdg±3dgt
±4.0%rdg±5dgt±6.0%rdg±5dgt
±1.5%rdg±5dgt±3.0%rdg±5dgt
±1.5%rdg±3dgt±3.0%rdg±3dgt
Range400A
1000A
400A
1000A
1Hz to 1kHz4V40V400V600V400mV4V40V400V600V1Hz to49.99kHz10% to 90%400Ω4kΩ40kΩ400kΩ4MΩ40MΩ
Continuity Test, Diode Test, Capacitance
Peak Hold (SK-7718), MAX / MIN, Difference,Power-on Initialize (for DC Current measurement),Range Hold (SK-7719), Display Hold,Auto Power OFF
A / A Hz
V / V Hz・%
APOMAXM I N
PEAKHOLD
AC/DC
VAC/DC
1000ADISPHOLDDIFF
Ω
TRUERMS
DUTY
%Hz
SK-7718 SK-7719 SK-7718
RNGHOLD
for DC Currentmeasurement
AUTOZERO
φ35mm
ConductorDiameter
FEATURES●AC / DC 1000A Measurements● "Power-On Initialize" (auto zero adjustment) for DCA.●MAX / MIN, Difference, Peak Hold (SK-7718), and Range
Hold (SK-7719)●Dust-proof case is used to protect the tester from dust damage.
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Frequency
Frequency
Duty Cycle
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 99993 times / secAuto Rangingφ35mm Max. 9V 6F22 Battery (x 1)CATⅢ 600V and EMC193(H) x 60(W) x 34.5(D) mm300g 100-57 Test Leads (x 1 set)1012 Carrying Case (x 1)9V 6F22 Battery (x 1)
OPTIONAL ACCESSORIES880 Line Separator100-41 Test Lead Kit100-62 Test Lead Set
940 Alligator Clips793 Coil-Type Contact Pin
DustProof
Simple WaterResistant
Simple WaterResistant
AC / DC Digital Clamp Meters
SK-7720 /SK-7722
PULSEWIDTH
MAXM I N
PEAKHOLD
2 Channel Measurements on Dual Display LCD and Oscilloscope Connection
AC/DC
VAC/DC
1000ADISPHOLDDIFF
DUTY
%HzΩ
TRUERMS
OUTPUT
SK-7722
Resistance
TemperatureFunctions
Range
400A / 1000A
Range400V650V
400A / 1000A
10.0Hz to 4000Hz0.0% to 99.9%1.0mS to 999.9mS
400V / 650V
10.0Hz to 4000Hz0.0% to 99.9%1.0mS to 999.9mS4000Ω20kΩ-30℃ to 150℃Peak Hold, MAX / MIN, Difference, Display Hold, Output Terminal (SK-7722)
Accuracy400.0A400 to 600A601 to 1000AAccuracy±1.0%rdg±3dgt±1.0%rdg±1dgt
400.0A400 to 600A601 to 1000A±0.5%rdg±1dgt±3.0%rdg±3dgt±0.5%rdg±3dgt±1.0%rdg±3dgt (50Hz to 60Hz)±1.5%rdg±3dgt (40Hz to 400Hz)±0.5%rdg±1dgt±3.0%rdg±3dgt±0.5%rdg±3dgt±1.0%rdg±3dgt±1.0%rdg±1dgt±1.0%rdg±3dgt
Range40V250V
Accuracy±1.0%rdg±3dgt±1.0%rdg±1dgt
40V / 250V±1.0%rdg±3dgt (50Hz to 60Hz)±1.5%rdg±3dgt (40Hz to 400Hz)
±1.5%rdg±3dgt±1.5%rdg±1dgt±3.0%rdg±3dgt
50Hz to 60Hz±1.5%rdg±3dgt±1.5%rdg±1dgt±3.0%rdg±3dgt
40Hz to 400Hz±2.5%rdg±3dgt±2.5%rdg±1dgt±4.0%rdg±3dgt
A + V
A + Hz
V + Hz
SK-7720 SK-7722
OPTIONAL ACCESSORIES818 Temperature Probe880 Line Separator922 Input Cord for Battery Power930 Output Cord for Recorder(SK-7722)
100-41 Test Lead Kit
FEATURES● Two different elements can be measured at once and
read on a bigger Dual Display LCD.● Analog Output Terminal for an Oscilloscope or Recorder (SK-7722).●Dust-proof case is used to protect the tester from dust damage.
DCVoltage
ACVoltage
DCCurrent
ACCurrent
FrequencyDuty CyclePulse Width
FrequencyDuty CyclePulse Width
SPECIFICATIONSDisplaySampling Rate
Range SelectionConductor DiameterPower SupplyDimensionsWeightAccessories
::
::::::
4000 count LCD, Maximum reading 999915 times / sec. (each channel), 3.75 times / sec. for A+V measurements in ordinary mode.Auto Rangingφ36mm Max. 9V 6F22 or NEDA 1604 Battery (x 1)200(H) x 64(W) x 33(D) mm310g100-57 Test Leads (x 1 set)1007 Carrying Case (x 1), 9V 6F22 Battery (x 1)
DustProof
100-62 Test Lead Set940 Alligator Clips793 Coil-Type Contact Pin
SK-7718
Clam
p M
etersInsulation Testers / Earth Tester
Dig
ital Mu
ltimeters
An
alog
Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
9
RNGHOLD
MAXM I N
PEAKHOLD
Powerful for Every Measurement
AC/DC
VAC/DC
2000ADISPHOLDDIFF
DUTY
%HzΩ
SK-7707/SK-7708
FEATURES● "Power-On Initialize" (auto zero adjustment) for DCA.● Peak Hold (SK-7708), MAX / MIN measurements.●Dust-proof case is used to protect the tester from dust damage.
TRUERMSAPS
A / A Hz
V / V Hz・%
Range
400A
2000A
400A2000A1Hz to 4.999kHz
4V / 40V / 400V / 600V400mV / 4V / 40V / 400V / 600V1Hz to 100kHz0.1% to 99.9%400Ω4kΩ / 40kΩ / 400kΩ4MΩ40MΩ
Continuity Test, Diode Test, Capacitance
MAX / MIN, Peak Hold (SK-7708), Difference, Power-on Initialize (for DC Current measurement), Range Hold, Display Hold, Auto Power Save
Accuracy
0 to 1000A1001A or more
±1.5%rdg±5dgt
±0.2%rdg±2dgt40Hz to 400Hz±1.5%rdg±5dgt ±1.2%rdg±3dgt ±0.2%rdg±2dgt±2.0%rdg±2dgt±1.5%rdg±5dgt±1.0%rdg±3dgt±3.0%rdg±4dgt±5.0%rdg±7dgt
401Hz to 1KHz±3.0%rdg±5dgt
50Hz to 60Hz±1.5%rdg±5dgt ±1.5%rdg±5dgt ±3.0%rdg±5dgt
40Hz to 1kHz±3.0%rdg±5dgt ±3.0%rdg±5dgt
for DC Currentmeasurement
AUTOZERO
RNGHOLD
MAXM I N
PEAKHOLD
Multi-Functional Clamp Meter with Quadruple Display
AC/DC
VAC/DC
2000ADISPHOLDDIFF
DUTY
%HzΩ
FEATURES●Relevant Measurement Items are Displayed while Current
and Voltage Measurements. ● Connectable to Oscilloscopes or Recorders.●Dust-proof case is used to protect the tester from dust damage.●High-speed sampling, 1000 times / sec.
Accuracy
±1.5%rdg±3dgt
±1.0%rdg±3dgt
±1.5%rdg±3dgt
±0.2%rdg±2dgt±5.0%rdg±2dgt±5.0%rdg±2dgt
±1.5%rdg±3dgt
±0.2%rdg±2dgt±5.0%rdg±2dgt±5.0%rdg±2dgt
±1.0%rdg±2dgt
±2℃
TRUERMS
A + V
A + Hz% / mS
V + Hz% / mS
Range400A2000A40V400V600V400A2000A10Hz to 25kHz1% to 99%0.1mS to 100mS40V400V600V10Hz to 25kHz1% to 99%0.1mS to 100mS4kΩ40kΩ-25℃ to 150℃
Continuity Test, Diode Test
MAX / MIN, Average, Peak Hold, Difference,Output Terminal, Range Hold, Display Hold,Auto Power Save
PULSEWIDTH
APSOUTPUT
AVERAGE
OPTIONAL ACCESSORIES818 Temperature Probe880 Line Separator100-41 Test Lead Kit
100-62 Test Lead Set940 Alligator Clips793 Coil-Type Contact Pin
φ55mm
ConductorDiameter
φ55mm
ConductorDiameter
Resistance
Temperature
Functions
OtherMeasurements
DCVoltage
ACVoltage
DCCurrent
ACCurrent
FrequencyDuty CyclePulse Width
FrequencyDuty CyclePulse Width
Resistance
OtherMeasurements
Functions
DC Voltage
ACVoltage
DCCurrent
ACCurrent
FrequencyDuty Cycle
Frequency
AC / DC Digital Clamp Meters
DustProof
DustProof
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 99991000 times / secAuto / Manual Rangingφ55mm Max. 9V 6F22 Battery (x 1)CATⅢ 600V and EMC 250(H) x 92(W) x 39(D) mm500g100-57 Test Leads (x 1 set)830 Output Cable1007 Carrying Case (x 1)9V 6F22 Battery (x 1)
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 51203 times / secAuto / Manual Rangingφ55mm Max. 9V 6F22 Battery (x 1)CATⅢ 600V and EMC250(H) x 92(W) x 39(D) mm500g 100-57 Test Leads (x 1 set)1007 Carrying Case (x 1)9V 6F22 Battery (x 1)
SK-7708
SK-7708
SK-7708
OPTIONAL ACCESSORIES880 Line Separator100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips793 Coil-Type Contact Pin
Simple WaterResistant
Simple WaterResistant
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
10
SK-7602
MAXM I N
Multi-functional Handy Clamp with Long Battery Life
AC/DC
VAC
400A
APODISPHOLDDIFF
DUTY
%HzΩ
FEATURES●290-hours long time measurement (SK-7603, with alkaline
cells) ● 13 measurement functions in one small package.● Rubber-molded rotary switch and trigger.● Easy-to-clamp compact & beaked clamp head even
for narrow conductors.● True RMS (SK-7660), MAX/MIN and Difference measurement.
Accuracy±1.5%rdg±5dgt (50Hz/60Hz)±3.0%rdg±5dgt (40Hz to 400Hz)±0.2%rdg±2dgt±1.0%rdg±3dgt
±1.0%rdg±2dgt
±1.5%rdg±5dgt (40Hz to 400Hz)
±0.2%rdg±2dgt
±2.0%rdg±3dgt±1.5%rdg±5dgt
±0.7%rdg±3dgt
±1.2%rdg±5dgt±3.0%rdg±5dgt
SK-7602
TRUERMS
A / Hz
V / VHz / %
Range40A400A5Hz to 1kHz400mV4V40V400V600V4V40V400V600V5Hz to49.99kHz5% to 95%400Ω4kΩ40kΩ400kΩ4MΩ40MΩ
Continuity Test, Diode Test, Capacitance
MAX / MIN, Difference, Display Hold,Auto Power OFF
Pocket-sized Clamp Meter
AC
200A APODISPHOLD
FEATURES●One-touch operation.● Strong and beaked Clamp Head against twists.●AUTO POWER OFF : turns off automatically after
10 minutes. ● Full Auto Ranging up to 200A AC.●DISPLAY HOLD Function.●With Carrying Case and spare Battery.
Accuracy
±1.8%rdg±5dgt
Range40A200A
Display Hold, Auto Power OFF
Easy & Useful
Easy - to - ClampSK-7602 / 7603's compact and beaked clamp heads assure easy clamping even for narrow conductors.
Avoid YourFingers SlipsSK-7602 / 7603 are always fit on your hand. Double-Molding Rubbers on a Function Switch and a Trigger avoid your fingers slips during operation.
Test LeadHolderFixable Test Lead on the side of SK-7602 / 7603 by inserting its hook into the holder socket. Useful for Voltage, Resistance, Capacitance Measurements, Continuity and Diode Tests.
OPTIONAL ACCESSORIES880 Line Separator940 Alligator Clips793 Coil-Type Contact Pin
φ27mm
ConductorDiameter
φ27mm
ConductorDiameter
ACCurrent
Functions
AC Digital Clamp Meters
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 43012.5 times / secAuto Rangingφ27mm Max. 3V CR2032 Battery (x 1)CATⅢ 300V and EMC 150(H) x 52(W) x 20(D)mm 110g1004 Carrying Case (x 1)3V CR2032 Battery (x 1 & spare)
OPTIONAL ACCESSORY880 Line Separator
SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:::::::::
4000 count LCD, Maximum reading 40503 times / secAuto Rangingφ27mm Max. 1.5V R03 or AAA Batteries (x 2)CATⅢ 300V, CATⅡ 600V and EMC 171(H) x 58(W) x 27(D)mm 140g100-63 Test Leads (x 1 set)1015 Carrying Case (x 1)1.5V R03 Batteries (x 2)
DCVoltage
ACVoltage
ACCurrent
Frequency
Frequency
Duty Cycle
Resistance
Functions
OtherMeasurements
φ27mm MAX
Clam
p M
etersInsulation Testers / Earth Tester
Dig
ital Mu
ltimeters
An
alog
Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
11
High Quality Clamp Meter that contains DMM functions
AC/DC
VAC
400A APODISPHOLDΩ
FEATURES● Round Clamp Head opens two ways at slant position
assures accuracy and easy use.● Easy Operation with Rotary Switch.●Wide Measurement Ranges.
2A20A200A400A
Accuracy±5.0%rdg±10dgt±2.0%rdg±7dgt
±1.5%rdg±7dgt
Accuracy
±1.0%rdg±5dgt
±0.5%rdg±2dgt±0.8%rdg±2dgt±1.0%rdg±2dgt±1.5%rdg±5dgt±3.0%rdg±5dgt±5.0%rdg±5dgt
Range
2A/20A
200A/400A
Range
2V/20V/200V/600V
200mV2V/20V/200V600V200Ω/2kΩ/20kΩ/200kΩ2MΩ20MΩ
Continuity Test, Diode Test
Display Hold, Auto Power OFF
High Quality Clamp Meter that contains DMM functions
AC/DC
VAC
600A APODISPHOLDΩ
2A20A200A600A
Accuracy±5.0%rdg±10dgt ±2.0%rdg±7dgt
±1.5%rdg±7dgt
Accuracy
±1.0%rdg±5dgt
±0.5%rdg±2dgt±0.8%rdg±2dgt±1.0%rdg±2dgt±1.5%rdg±5dgt±3.0%rdg±5dgt±5.0%rdg±5dgt
Range
2A/20A
200A/600A
Range
2V/20V/200V/600V
200mV2V/20V/200V600V200Ω/2kΩ/20kΩ/200kΩ2MΩ20MΩ
Continuity Test, Diode Test
Display Hold, Auto Power OFF
φ26mm
ConductorDiameter
φ42mm
ConductorDiameter
AC Digital Clamp Meters
SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyDimensionsWeightAccessories
::::::::
2000 count LCD, Maximum reading 19993 times / secAuto Ranging(two-ranges auto for ACA)φ26mm Max. 1.5V LR-44 Batteries (x 2) 171(H) x 72(W) x 35(D) mm180g 100-57 Test Leads (x 1 set)983 Carrying Case (x 1)1.5V LR-44 Batteries (x 2)
FEATURES● Round Clamp Head opens two ways at slant position
assures accuracy and easy use.● Easy Operation with Rotary Switch.●Wide Measurement Ranges.
SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyDimensionsWeightAccessories
::::::::
2000 count LCD, Maximum reading 19993 times / secAuto Ranging (two-ranges auto for ACA)φ42mm Max. 1.5V LR-44 Batteries (x 2) 183(H) x 78(W) x 35(D) mm210g 100-57 Test Leads (x 1 set)983 Carrying Case (x 1)1.5V LR-44 Batteries (x 2)
DCVoltage
ACVoltage
ACCurrent
Resistance
Functions
OtherMeasurements
OPTIONAL ACCESSORIES880 Line Separator100-41 Test Lead Kit100-62 Test Lead Set
940 Alligator Clips793 Coil-Type Contact Pin
940 Alligator Clips793 Coil-Type Contact Pin
DCVoltage
ACVoltage
ACCurrent
Resistance
OtherMeasurementsFunctions
OPTIONAL ACCESSORIES880 Line Separator100-41 Test Lead Kit100-62 Test Lead Set
940 Alligator Clips793 Coil-Type Contact Pin
FEATURES●Auto ranging with Range Hold Function.● Easy to Clamp by Beaked Clamp Head.●Dust-proof case is used to protect the tester from dust damage.
OPTIONAL ACCESSORIES880 Line Separator100-41 Test Lead Kit100-62 Test Lead Set
Accuracy
0 to 600A
0 to 1000A
1001A or more
±1.5%rdg±5dgt (40Hz to 400Hz)
±1.2%rdg±3dgt
±1.5%rdg±5dgt
±1.0%rdg±3dgt
±3.0%rdg±4dgt±5.0%rdg±7dgt
±1.5%rdg±5dgt (50Hz/60Hz)±3%rdg±5dgt (40Hz to 1kHz)±1.5%rdg±5dgt (50Hz/60Hz)±3%rdg±5dgt (40Hz to 1kHz)±3%rdg±5dgt (50Hz/60Hz)
Range
400A
2000A
4V40V400V600V400mV4V40V400V600V400Ω4kΩ40kΩ400kΩ4MΩ40MΩFrequency, Duty Cycle, Continuity Test,Diode Test, CapacitanceMAX / MIN, Difference, Range Hold, Display Hold, Auto Power Save
A Hz・%
V / V Hz・%
RNGHOLD
MAXM I N
High-Valued Clamp Meter
AC/DC
VAC
2000ADISPHOLDDIFF
DUTY
%HzΩTRUERMSAPS
±3%rdg±5dgt (401Hz to 1kHz)
φ55mm
ConductorDiameter
SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:::::::::
4000 count LCD, Maximum reading 49993 times / secAuto / Manual Rangingφ55mm Max. 9V 6F22 Battery (x 1) CATⅢ 600V and EMC 250(H) x 92(W) x 39(D) mm470g100-57 Test Leads (x 1 set)1007 Carrying Case (x 1)9V 6F22 Battery (x 1)
DCVoltage
ACVoltage
ACCurrent
Resistance
OtherMeasurements
Functions
DustProof
Simple WaterResistant
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
12
Advantages of SK-7820 / 7825
FEATURES●Wide range from 40mA to 100A AC.● Vibration and buzzer comparator convenient in noisy
surroundings. ● Low pass filter (cutoff 150Hz or more)● 100-hours continuous measurement (with alkaline cells)● Rubber-molded rotaty switch and trigger neatly fit in
your hand.
OPTIONAL ACCESSORIES880 Line Separator940 Alligator Clips
793 Coil-Type Contact Pin
SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyCE Mark Dimensions
WeightAccessories
:::::::
::
4000 count LCD, Maximum reading 40502 times / sec Auto Ranging (mA / A : switch selection)SK-7820:φ24mm Max., SK-7825:φ40mm Max.1.5V (L) R03 or AAA Batteries (x 2) CATⅢ 300V, CATⅡ 600V and EMCSK-7820:168(H) x 58(W) x 27(D) mmSK-7825:184(H) x 58(W) x 27(D) mmSK-7820:170g, SK-7825:180g 100-63 Test Leads (x 1 set)1020 Carrying Case (x 1), 1.5V LR03 Batteries (x 2)
SK-7825
The World's First Vibration Alert Comparator Installed Clamps
AC
VAPODISP
HOLD
SK-7820/SK-7825
LPFCOMP
ACCurrent
Functions
ACVoltage
Accuracy (50/60Hz)0.10mA to 1.00mA1.01mA or more0.10A to 1.00A1.01A or more40.1A to 80.0A80.1A to 100.0A5.0V to 10.0V10.1V or more
Filter ON (50/60Hz)
add ±1.0%rdg±3dgt
add ±1.0%rdg±3dgt
Frequency Characteristic (40 to 400Hz)
add ±1.0%rdg±3dgt
add ±1.0%rdg±3dgt
±1.0%rdg±7dgt±1.0%rdg±5dgt±2.0%rdg±7dgt±2.0%rdg±5dgt±2.0%rdg±5dgt±4.0%rdg±5dgt ±2.0%rdg±7dgt±2.0%rdg±5dgt
Range
40mA / 400mA
40A
100A
400V / 600V
Vibration alert comparator, Low pass filter, Display Hold, Auto Power OFF
AC
100A
φ40mm
ConductorDiameter
SK-7825
φ24mm
ConductorDiameter
SK-7820
Vibration Alert ComparatorSK-7820 / 7825 incorporate Comparator Function in ~mA range. Buzzer sounds and vibrates if measuring value exceeds the setting value. Even in noisy surroundings, that can drown out the buzzer sound, vibration helps your comparator measurement. (Vibration alert is cancelable.)
Two-types-of Clamp HeadSK-7820's small clamp head assures easy clamping even for narrow conductors. SK-7825's large clamp head is suitable for thick conductors' measurement like 3-phase 3-wire system.
SK-7820
φ24mm Max φ40mm Max
SK-7820 SK-7825
SK-7810
FEATURES● Easy to read LCD.● Comparator : 1mA to 20mA setting. Buzzer sounds
when measured value exceeds the set point.●Max / Min Measurement.●Analog output for recorders. (SK-7810)
● Low Pass Filter cuts off frequencies higher than 150Hz.●Display Hold & Auto Power Save.● Power Hold enables longer measurements.●CE Mark is approved, EMC and LVD (IEC-1010-1) passed.
OPTIONAL ACCESSORIES880 Line Separator100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips793 Coil-Type Contact Pin932 Output Cord for Recorder (SK-7810)
φ30mm
ConductorDiameter
SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:::::::::
3200 count LCD, Maximum reading 32002 times / sec Manual (SK-7810), Auto (SK-7815)φ30mm Max. 1.5V R6P or AA Batteries (x 2) CATⅢ 300V and EMC212(H) x 42(W) x 30(D) mm220g 100-32 Test Leads (x 1 set, for SK-7815)1011 Carrying Case (x 1)1.5V R6P Batteries (x 2)
MAXM I N
Leakage Clamp with Comparator
SK-7810/SK-7815
APODISPHOLDLPFCOMP OUT
PUT
AC
60A
AC Leakage Clamp Meters
SK-7810
Accuracy
±1.0%rdg±5dgt
0A to 50A50.01A to 60.0A
±1.0%rdg±5dgt±5.0%rdg±5dgt
Range30mA300mA
60A
Output Terminal, MAX / MIN,Comparator (up to 20mA), Low pass filter, Display Hold, Auto Power Save
ACCurrent
SK-7810
Functions
Accuracy
±1.0%rdg±5dgt
±1.5%rdg±5dgt0A to 27.0A27.1A to 50.00A50.1A to 60.0A
±2.0%rdg±5dgt
±1.5%rdg±5dgt±2.0%rdg±5dgt ±5.0%rdg±5dgt
Range30mA300mA30A
60A
300V / 600V
MAX / MIN, Comparator (up to 20mA), Low pass filter, Display Hold, Auto Power Save
ACCurrent
SK-7815
ACVoltage
Functions
Clam
p M
etersInsulation Testers / Earth Tester
Dig
ital Mu
ltimeters
An
alog
Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
13
Insulation Testers Index
Model
Digital / Analog
Measurement Ranges
Insulation Resistance
Low Resistance
DC Voltage
AC Voltage
Continuity Test
Comparator
Data Memory
Timer
Live wire warning
Safety lock
High voltage warning
Automatic discharge
Display hold
Zero-ohm adjustment
Auto power save
Digital
4-Ranges
50V
125V
250V
500V
●●●-●●●●●●●●●●
SK-3500
Digital
4-Ranges
125V
250V
500V
1000V
●●●-●●●●●●●●●●
SK-3502
Analog
2-Ranges
100V
250V
----●---●-------
SK-3000
Analog
2-Ranges
250V
500V
----●---●-------
SK-3002
Analog
2-Ranges
500V
1000V
----●---●-------
SK-3003
Model
Digital / Analog
Measurement Ranges
Insulation Resistance
Low Resistance
DC Voltage
AC Voltage
Continuity Test
Comparator
Data Memory
Timer
Live wire warning
Safety lock
High voltage warning
Automatic discharge
Display hold
Zero-ohm adjustment
Auto power save
Analog
2-Ranges
50V
125V
----●---●●-●●---
SK-3010
Analog
2-Ranges
250V
500V
----●---●●-●●---
SK-3012
Analog
2-Ranges
500V
1000V
----●---●●-●●---
SK-3013
Analog
2-Ranges
500V
1000V
--●-●●--●●-●●---
Analog
3-Ranges
250V
500V
1000V
---●---●●-●●---
SK-3320
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
14
SK-3502
50V 125V 250V 500V 125V 250V 500V 1000V
Compact, But Powerfull. Versatile 4-Range Insulation Tester
SK-3500/SK-3502
FEATURES●Wide Range of Insulation Measurement with Enhanced Safety.● Comparator Function.●Data Memory Function. (up to 100 data)
AC/DC
VDISPHOLD
DATAMEMO APSCOMP
50V200MΩ
SK-3500
125V200MΩ
250V2000MΩ
500V2000MΩ
1000V2000MΩ
SK-3502
ΩLOW
SK-3500 SK-3502
200MΩ5MΩ
0.200 to 10 MΩ
0 to 0.199 MΩ, 10.01 to 200.0 MΩ
2000MΩ50MΩ
0.200 to 100 MΩ
0 to 0.199 MΩ100.1 to 2000 MΩ
200MΩ5MΩ
0.200 to 10 MΩ
0 to 0.199 MΩ, 10.01 to 200.0 MΩ
2000MΩ50MΩ
0.200 to 100 MΩ
0 to 0.199 MΩ, 100.1 to 2000 MΩ
±3%rdg±4dgt
±5%rdg±5dgt
±3%rdg±4dgt
±5%rdg±5dgt
Comparator, Data memory, Timer, Live wire warning, Safety lock, High voltage warning, Automatic discharge, Zero-ohm adjustment, BacklightDisplay hold, Auto power save
Common to SK-3500 / SK-350220.00Ω
200mA or more
DCV / ACV fixed (0V to 600V)
±3%rdg±5dgt
6V or more
±3%rdg±5dgtApprox. 660kΩ
400.0Ω
Approx. 10mA
AUTO (10V to 600V)
Multi-Functional Insulation Testers
SK-3000/SK-3002/SK-3003
AC
V250V
500MΩ
SK-3000
100V200MΩ
SK-3000
250V50MΩ
SK-3002
500V100MΩ
SK-3002
500V1000MΩ
SK-3003
1000V2000MΩ
SK-3003
100V 250V 250V 500V 500V 1000VSK-3000 SK-3002 SK-3003
200MΩ0.1 to 200MΩ
5MΩ
500MΩ0.5 to 500MΩ
10MΩ
50MΩ0.05 to 50MΩ
1MΩ
100MΩ0.1 to 100MΩ
2MΩ
1000MΩ1 to 1000MΩ
20MΩ
2000MΩ2 to 2000MΩ
50MΩInfinite Scale : ±10% of Rated Voltage Center Scale : Over 90% of Rated Voltage
First effective range : ±5% of reading valueSecond effective range : ±10% of reading value
Zero and Infinite : ±0.7% of scale length0 to 600V
±3% of full scale valueApprox. 3 minutes
by Battery Scale on BATT. CHECK position
Rated Test Voltage (DC)Max. Effective ReadingEffective rangeCenter ScaleTerminal VoltageAccuracy
RangeAccuracy
Load
Power SourceL side E side
OFF
How to measure Volume Resistance Insulation Resistance Measurements
SK-3003
Digital Insulation Testers
Analog Insulation Testers
SPECIFICATIONSDisplaySampling RatePower SupplyFuseCE MarkDimensionsWeightAccessories
::::::::
4000 count LCD, Maximum reading 40002 times / sec 1.5V R6P or AA Batteries (x 8)F22 (0.5A / 600V) x 1CATⅣ 600V CLASSⅡand EMC120(H) x 130(W) x 70(D) mm600g100-61 Test Leads (x 1 set), 945B Black Alligator Clip (x 1)1016 Carrying Case (x 1), 1.5V P6P Batteries (x 8)Spare Fuse F22 (0.5A / 600V) x 1 (built-in)
SimpleDust Proof
SimpleWater Resistant
OPTIONAL ACCESSORIES766B Black Test Prod (with 767 Test Pin)940R Red Alligator Clip
Rated Test Voltage (DC)Max. Effective ReadingCenter Reading1st effective rangeAccuracy2nd effective range
Accuracy
Display Range (Auto-ranging)Accuracy (After 0Ω Adjustment)Measurement CurrentOpen Circuit VoltageRangeAccuracyInput Resistance
SPECIFICATIONSPower SupplyDimensionsWeightAccessories
::::
1.5V R6P or AA Batteries (x 8)165(H) x 100(W) x 45(D) mm540g100-34 Test Leads (x 1 set), Test Pin (x 1)978 Carrying Case (x 1), 1.5V R6P Batteries (x 8)
InsulationResistance
InsulationResistance
LowResistance
ACVoltage
TimerBattery Check
AC / DCVoltage
Functions
CoreConductor
Insulator
LeadCoating
Before measurement, make sure that the line (circuit) or object under test is not live.
Clam
p M
etersInsulation Testers / Earth Tester
Dig
ital Mu
ltimeters
An
alog
Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
15
50V 125V 250V 500V 500V 1000V 250V 500V 1000V
All-in-one Insulation Tester with Safety Functions
AC
V
50V10MΩ
SK-3010
125V20MΩ
SK-3010
250V50MΩ
SK-3320
500V100MΩ
SK-3320
1000V2000MΩ
SK-3320
250V50MΩ
SK-3012
500V100MΩ
SK-3012
500V1000MΩ
SK-3013
1000V2000MΩ
SK-3013
500V100MΩ
SK-3016
1000V200MΩ
SK-3016
SK-3010 SK-3012 SK-3016SK-3013 SK-3320
10MΩ0.005 to 10MΩ
0.2MΩ
0 to 300V
---
---
---
2Ω/20Ω (OpenV. ≧5V, M.C.200mA)±3% full scale length
Buzzer sounds less than 1Ω / 10Ω
---
0 to 600V
20MΩ0.01 to 20MΩ
0.5MΩ
50MΩ0.01 to 50MΩ
1MΩ
100MΩ0.05 to 100MΩ
2MΩless than 1.3 times of Rated Voltage
1mA to 1.2mA less than 2mA
First effective range : ±5% of reading value Second effective range : ±10% of reading valueThe other area of scale : ±0.7% of scale length
±3% of full scale value
Approx. 3 minutesby Battery Scale on BATT. CHECK position
1000MΩ0.5 to 1000MΩ
20MΩ
2000MΩ1 to 2000MΩ
50MΩ
500V 1000V100MΩ
0.05 to 100MΩ2MΩ
200MΩ0.1 to 200MΩ
5MΩ
50MΩ0.01 to 50MΩ
1MΩ
100MΩ0.05 to 100MΩ
2MΩ
2000MΩ1 to 2000MΩ
50MΩ
OPTIONAL ACCESSORIES766B Black Test Prod (with 767B Test Pin)942R Red Alligator Clip
OPTIONAL ACCESSORIES771 Measuring Cord (40m)777 Two Auxiliary Earthing Sheets
Rated Test Voltage (DC)Max. Effective ReadingEffective rangeCenter ScaleAllowable Voltage at no loadRated Measuring CurrentShorted CurrentAccuracy
RangeAccuracyRangeAccuracy
Live wire warning, High voltage warning, Automatic discharge
FEATURES●Dust proof and water resistant case.● 3-minutes continuous measurement. (Timer Function)● Enhanced safety. (Live wire warning and Automatic
discharge)● Low Resistance and Continuity measurements. (SK-3016)
Automatic Earth Tester
FEATURES●VOLTAGE DROP SYSTEM enables the SK-3710 to measure
EARTH RESISTANCE automatically with one press of POWER Switch only.
●Simple Measurements are available by shorting P terminal and C terminal with attached cord.
● Taut Band Meter Movement of Drop-proof and Internal Core Magnet type minimizes outside magnetic influence and assures trouble-free performance.
● CE Mark is approved with EMCD and LVD (IEC 1010-1) passed.
SK-3710
A. Earth Resistance Range : 10Ω / 100Ω / 1000ΩB. Earth Voltage : 30VA. Earth Resistance : ±5% of full scale value
1. Effect of Earth Voltage : Less than ±5% ofreading value when earth voltage is 5V
2. Effect of Auxiliary Earthing Resistance : ±10% of reading value when AuxiliaryEarthing Resistance is 5kΩ
3. Other : In accordance with JIS C-1304 B. Earth Voltage : ±3% of full scale valueThe deflection method of Voltage Drop System isadopted.by POWER / BATT LED Lamp
Basic Measurement
5 to 10m 5 to 10mPUSH ON ~V
~VE P C
×1 ×10
×100
Ω
AUTOMATIC EARTH TESTER SK-3710
E P C
Do not fail to confirm that the value of AUXILIARY EARTH RESISTANCE is less than 5kΩ.If AUXILIARY EARTH RODs cannot be inserted (for example,concrete), use optional AUXILIARY EARTH SHEET.
Analog Insulation Testers
Earth Tester
SPECIFICATIONSPower SupplyFuseCE MarkDimensionsWeightAccessories
::::::
1.5V R6P or AA Batteries (x 6)F23 (1A / 600V) x 1CATⅢ 600V and EMC169(H) x 148(W) x 50(D) mm570g100-40-2 Test Leads (x 1 set)942B Black Alligator Clip (x 1)766R Red Test Prod (x 1, with 767R Test Pin)1.5V P6P Batteries (x 6)Spare Fuse F23 (1A / 600V) x 1
SPECIFICATIONSPower SupplyDimensionsWeightAccessories
::::
1.5V R6P or AA Batteries (x 8)165(H) x 100(W) x 72(D) mm550g770 Measuring Cords (x 1 set) (5m, 10m, 20m, Single Measuring Cord)775 Auxiliary Earthing Rods (x 1 set)776 Sack for Accessories (x 1)988 Carrying Case (x 1)1.5V R6P Batteries (x 8)
DustProof
WaterResistant
InsulationResistance
ACVoltage
TimerContinuity Test
LowResistance
Battery CheckFunctions
Range andVoltage
Accuracy(20℃)
MeasuringSystem
Battery Check
GreenCord
YellowCord
RedCord
SK-3010
ΩLOW
SK-3016 SK-3016
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
16
Digital Multimeters Index
Model
Display Counts
Bargraph
DC Voltage
AC Voltage
DC Current
AC Current
Resistance
Frequency
Duty Cycle
Continuity Test
Diode Test
Capacitance
Temperature
True RMS
Auto Ranging
Manual Ranging
MAX / MIN
Range Hold
Difference
Display Hold
Comparator
Current by Clamp Adapter
Dust Proof & Simple Water Resistant
Auto Power Save (Off)
4000
-
400mV
4V
40V
400V
1000V
-
4V
40V
400V
750V
-
-
40mA
400mA
4A
20A
-
-
40mA
400mA
4A
20A
-
-
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
●
●
●
●
-
-
-
●
●
-
●
-
-
-
●-
●
4000
-
400mV
4V
40V
400V
1000V
-
4V
40V
400V
750V
-
-
400μA
4000μA
40mA
400mA
4A
20A
400μA
4000μA
40mA
400mA
4A
20A
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
●
●
●
●
●
-
-
●
●
-
●
●
●
-
●-
●
4000
●400mV
4V
40V
400V
1000V
-400mV
4V
40V
400V
750V
-400mA
20A
----
400mA
20A
----
400Ω4kΩ40kΩ
400kΩ4MΩ40MΩ●-●●---●●●●●●-●●●
4000
-
400mV
4V
40V
400V
600V
-
400mV
4V
40V
400V
600V
-
400μA
4000μA
40mA
400mA
4A
10A
400μA
4000μA
40mA
400mA
4A
10A
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
●
●
●
●
●
●
-
●
●
-
●
●
●
-
●
-
●
Clam
p M
etersInsulation Testers / Earth Tester
Dig
ital Mu
ltimeters
An
alog
Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
17
Digital Multimeters Index
Model
Display Counts
Bargraph
DC Voltage
AC Voltage
DC Current
AC Current
Resistance
Frequency
Duty Cycle
Continuity Test
Diode Test
Capacitance
Temperature
True RMS
Auto Ranging
Manual Ranging
MAX / MIN
Range Hold
Difference
Display Hold
Comparator
Current by Clamp Adapter
Dust Proof & Simple Water Resistant
Auto Power Save (Off)
4000
-400mV
4.0V
40V
400V
600V
-4.0V
40V
400V
600V
-------
-----
400Ω4.0kΩ40kΩ
400kΩ4.0MΩ40MΩ●●●●●--●●●●●●---●
4000
-400mV
4.0V
40V
400V
600V
-4.0V
40V
400V
600V
-------
-----
400Ω4.0kΩ40kΩ
400kΩ4.0MΩ40MΩ●●●●●--●-●-●●---●
2000
-200mV
2V
20V
200V
600V
-2V
20V
200V
600V
-------
-----
200Ω2kΩ20kΩ
200kΩ2MΩ
20MΩ--●●---●----●---●
4000
-
400mV
4V
40V
400V
600V
-
400mV
4V
40V
400V
600V
-
400μA
4000μA
40mA
400mA
10A
-
400μA
4000μA
40mA
400mA
10A
-
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
-
-
-
-
-
-
-
●
●
-
●
-
-
●
●
-
-
SK-4033
4000
-
400mV
4V
40V
400V
600V
-
400mV
4V
40V
400V
600V
-
400μA
4000μA
40mA
400mA
10A
-
400μA
4000μA
40mA
400mA
10A
-
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
-
-
-
-
-
-
●
●
●
-
●
-
-
●
●
-
-
SK-4035
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
SK-6161
::
:::
:::
SPECIFICATIONSDisplaySampling Rate
Range SelectionPower SupplyFuse
Dimensions WeightAccessories
4000 count LCD 2.5 times / sec(except frequency duty cycle, capacitance measurements)Auto / Manual Ranging1.5V R6P or AA Batteries (x 2)F14 (0.5A / 250V) x 1 F16 (15A / 250V) x 1160(H) x 75(W) x 34(D) mm, 180g100-57 Test Leads (x 1 set)1020 Carrying Case1.5V R6P Batteries (x 2)Spare Fuses F14 (0.5A / 250V) &F16 (15A / 250V), x 1 each
Advantages of SK-6161/ 6163
Easy-to-readlarge LCD
Colored range switchfor easy operation
18
Digital Multimeters (Handy Type)
High Cost Performance, Temperature Measurement
AC/DC
VAC/DC
A APODISPHOLD
RNGHOLDDIFF
DUTY
%HzΩ
FEATURES●Temperature Measurement. (Temperature Probe is provided)● Tilt Stand and Test Lead Holder on rear side.● Display Hold, Range Hold functions.● Auto Power Off, Reset functions.
Range400mV4V40V400V600V400mV4V40V400V600VRange400μA/4000μA40mA/400mA4A/10A400μA/4000μA40mA/400mA4A/10ARange400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : Approx. 0.44VRange0℃ to 40℃-20℃ to 200℃200℃ to 500℃Frequency, Duty Cycle, Current by Clamp Adapter,Continuity Test, Diode Test, CapacitanceDifference, Range Hold, Display Hold, Auto Power Off, Reset
Resolution0.1mV1mV10mV100mV1V0.1mV1mV10mV100mV1VResolution0.1μA/1μA10μA/100μA1mA/10mA0.1μA/1μA10μA/100μA1mA/10mAResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Resolution
1℃
Accuracy
±0.5%rdg±5dgt
±0.8%rdg±5dgt±1.2%rdg±5dgt
±0.8%rdg±5dgt
±1.2%rdg±5dgtAccuracy
±1.5%rdg±5dgt
±2.0%rdg±5dgt
±2.0%rdg±5dgt
±2.5%rdg±5dgtAccuracy
±1.0%rdg±5dgt
±2.0%rdg±5dgt
Accuracy±3℃±0.75%rdg±3℃±1.5%rdg±3℃
Input Impedance>100MΩ≒11MΩ
≒10MΩ
≒11MΩ
≒10MΩ
Voltage Drop40mV/400mV70mV/700mV500mV/1.4V40mV/400mV70mV/700mV500mV/1.4VTest Current≦0.3mA≦40μA≦4μA≦0.4μA
≦40nA
SensorBuilt-in
External
Range400mV4V40/400/1000V4V40/400/750VRange400μ/4000μA*40m/400mA4A
20A
400μ/4000μA*40m/400mA4A
20A
Range400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : Approx. 0.44VFrequency, Duty Cycle, Current by Clamp Adapter,Continuity Test, Diode Test, Capacitance (SK-6163)Difference (SK-6163), Range Hold, Display Hold (SK-6163), Auto Power Save
Resolution0.1mV1mV10m/100m/1V1mV10m/100m/1VResolution0.1μ/1μA0.01m/0.1mA1mA
10mA
0.1μ/1μA0.01m/0.1mA1mA
10mA
Resolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy±0.5%rdg±2dgt
±0.5%rdg±1dgt
±1%rdg±5dgt
Accuracy±1%rdg±1dgt±1%rdg±1dgt±1.5%rdg±2dgt0~10.00A ±1.5%rdg±2dgt10.01~20.00A ±2.5%rdg±4dgt±1.5%rdg±5dgt±1.5%rdg±5dgt±2%rdg±7dgt0~10.00A ±2%rdg±7dgt10.01~20.00A ±3%rdg±7dgtAccuracy±0.8%rdg±3dgt
±0.8%rdg±2dgt
±2%rdg±3dgt±3%rdg±3dgt
Input Impedance>100MΩ≒11MΩ≒10MΩ≒11MΩ≒10MΩVoltage Drop0.11mV/μA2mV/mA30mV/A
30mV/A
0.11mV/μA2mV/mA30mV/A
30mV/A
Test Current≦0.3mA≦40μA≦4μA≦0.4μA
≦40nA
Easy-to-read Large LCD with 20mm high numerals
AC/DC
VAC/DC
A Ω
FEATURES● Easy-to-read Large LCD with 20mm high numerals.● 300 hours continuous operation with only two 1.5V Batteries.● 20A AC / DC Measurements.
SK-6163SK-6163 SK-6163
* 400μA / 4000μA range is SK-6163 only.
SK-6163
APSDISPHOLD
RNGHOLDDIFF
DUTY
%Hz
100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips793 Coil-Type Contact Pin995 Carrying Case
OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter821 AC Clamp Adapter817-01~817-25 Temperature probe731 BNC Conversion Adapter732 Miniature ConnectorConversion Plug
100-62 Test Lead Set940 Alligator Clips793 Coil-Type Contact Pin
OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter821 AC Clamp Adapter731 BNC Conversion Adapter100-41 Test Lead Kit
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkFuse
Dimensions WeightAccessories
::::::
:::
4000 count LCD2 times / secAuto / Manual Ranging1.5V R6P or AA Batteries (x 2)CATⅡ600V, CATⅢ 300V compliantF14 (0.5A / 250V) x 1F17 (10A / 250V) x 1155(H) x 75(W) x 29(D) mm 180gHolster, 100-50 Test Leads (x 1 set)818-02 Temperature Probe (x 1)1.5V R6P Batteries (x2 & spare)Spare Fuses F14 (0.5A/250V), F17 (10A/250V), x 1 each
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Resistance
Temperature
Other Measurements
Functions
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Other Measurements
Functions
Resistance
Clam
p M
etersInsulation Testers / Earth Tester
Dig
ital Mu
ltimeters
An
alog
Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
19
Digital Multimeters (Handy Type)
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Resistance
Other Measurements
Functions
Range400mV4V40V400V1000V400mV4V40V400V750VRange400mA
20A
400mA
20A
Range400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : ≦0.4VFrequency, Continuity Test, Diode Test, Current (400A AC / DC) by Clamp AdapterMAX / MIN, Difference, Range Hold, Display Hold, Auto Power Save
Resolution100μV1mV10mV100mV1V100μV1mV10mV100mV1VResolution100μA
10mA
100μA
10mA
Resolution100mΩ1Ω10Ω100Ω1kΩ10kΩ
Accuracy
±0.5%rdg±2dgt
±0.8%rdg±1dgt
±2.0%rdg±7dgt
±1.5%rdg±5dgt
Accuracy±1.2%rdg±2dgt0 to 10.00A±2.0%rdg±2dgt10.01 to 20A ±2.5%rdg±4dgt±2.5%rdg±5dgt0 to 10.00A±2.5%rdg±5dgt10.01 to 20A±3.0%rdg±10dgtAccuracy±1.0%rdg±2dgt
±0.7%rdg±2dgt
±1.0%rdg±2dgt±2.0%rdg±2dgt
Input Impedance≧100MΩ≒11MΩ
≒10MΩ
≧100MΩ≒11MΩ
≒10MΩ
Voltage Drop400mV
350mV(10A)
400mV
350mV(10A)
Test Current≦0.5mA≦0.2mA≦40μA≦4μA≦0.4μA≦40nA
4000 Count DMM with Bargraph
AC/DC
VAC/DC
ARNGHOLD
ΩFEATURES● Large LCD with Bargraph.● Tough designed case with Dust-proof and
Water-resistant structure.
SPECIFICATIONSDisplay
Sampling Rate
Range SelectionPower SupplyFuseDimensions WeightAccessories
:
:
::::::
(Numerical) 4000 count LCD,Maximum Reading 9999(Bargraph) 40 segments(1 segment / 100 digits)(Numerical) 2 times / sec(Bargraph) 20 times / secAuto / Manual Ranging1.5V R6P or AA Batteries (x 2)F26 (1A / 600V) x 1, F25 (15A / 600V) x 1180(H) x 86(W) x 35(D) mm 320g100-57 Test Leads (x 1 set)1.5V R6P Batteries (x 2)
DISPHOLD
OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter821 AC Clamp Adapter731 BNC Conversion Adapter 100-41 Test Lead Kit
100-62 Test Lead Set940 Alligator Clips793 Coil-Type Contact Pin995 Carrying Case
793 Coil-Type Contact Pin
BARGRAPH
APSMAXM I N DIFF
Hz
DustProof
Simple & Easy
Range200mV2V20V200V600V2V20V200V600VRange200Ω2kΩ20kΩ200kΩ2MΩ20MΩOpen Circuit Voltage : ≦0.45V
Diode Test, Continuity Test
Display Hold, Auto Power Off
Resolution100μV1mV10mV100mV1V1mV10mV100mV1VResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy±1.3%rdg±5dgt
±1.3%rdg±3dgt
±2.0%rdg±8dgt
Accuracy
±2.0%rdg±4dgt
±5.0%rdg±4dgt
Input Impedance≧100MΩ≒12MΩ
≒10MΩ
≒12MΩ
≒10MΩ
Test Current≦1mA≦0.3mA≦40μA≦4μA≦0.4μA≦0.04μA
AC/DC
V APODISPHOLDΩ
DCVoltage
ACVoltage
Resistance
Other MeasurementsFunctions
Digital Multimeters (Card-Type DMM)
OPTIONAL ACCESSORY940 Alligator Clips
FEATURES● Compact & Light Weight.●Wide Measurement Ranges.●Gold-plated Test Lead Pins.
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkDimensions WeightAccessories
::::::::
2000 count LCD 3 times / secAuto Ranging3V CR2032 Battery (x 1)CATⅡ600V, CATⅢ 300V and EMC109(H) x 55(W) x 9(D) mm Approx. 60g3V CR2032 Battery (x 1), Note-book type Carrying Case
● Large Rotary Switch.●Useful Functions.
High-Precision DMM
Digital Multimeters (All-in-one DMM)
Range400mV4.0V40V400V/600V4.0V40V/400V600VRange400Ω4.0kΩ40kΩ400kΩ4.0MΩ40MΩOpen Circuit Voltage : ≒0.44VFrequency, Duty Cycle, Continuity Test, Diode Test,CapacitanceMAX / MIN, Difference, Range Hold, Display Hold,Auto Power Save
Resolution100μV1mV10mV100mV/1V1mV10mV/100mV1VResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy
±0.5%rdg±3dgt
±1.0%rdg±3dgt
±1.5%rdg±5dgt
Accuracy±1.5%rdg±4dgt
±1.0%rdg±3dgt
±3.0%rdg±3dgt±7.0%rdg±3dgt
Input Impedance≧100MΩ≒11MΩ
≒10MΩ
≒11MΩ
≒10MΩ
Test Current≦0.2mA≦50μA≦5μA≦0.5μA
≦50nA
AC/DC
V
APSDISPHOLD
MAXM I N
RNGHOLDDIFF
DUTY
%HzΩ
DCVoltage
ACVoltage
Resistance
Other Measurements
FunctionsOPTIONAL ACCESSORY940 Alligator Clips793 Coil-Type Contact Pin
FEATURES●Multi-functional Card Type DMM comparable to Large Multi meter.● Very Useful for Any Measurement Conditions.
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkDimensions WeightAccessories
::::::::
4000 count LCD 3 times / secAuto / Manual Ranging3V CR2032 Battery (x 1)CATⅢ 300V and EMC118(H) x 78(W) x 16(D) mm 110g3V CR2032 Battery (x 1)
Simple WaterResistantC
lam
p M
eter
sIn
sula
tion
Test
ers /
Ear
th Te
ster
Dig
ital
Mu
ltim
eter
sA
nal
og
Mu
ltit
este
rsA
uto
mo
tive
Tes
ters
Oth
er T
este
rsA
cces
sori
es
Multi-Functional and Versatile Probe Tester
Range400mV4.0V40V400V/600V4.0V40V/400V600VRange400Ω4.0kΩ40kΩ400kΩ4.0MΩ40MΩOpen Circuit Voltage : ≒0.44VFrequency, Duty Cycle, Continuity Test, Diode Test,CapacitanceMAX / MIN, Difference, Display Hold, Auto Power Off
Resolution100μV1mV10mV100mV/1V1mV10mV/100mV1VResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy
±0.5%rdg±3dgt
±1.0%rdg±3dgt
±1.5%rdg±5dgt
Accuracy±1.5%rdg±4dgt
±1.0%rdg±3dgt
±5.0%rdg±3dgt±7.0%rdg±3dgt
Input Impedance≧100MΩ≒11MΩ
≒10MΩ
≒11MΩ
≒10MΩ
Test Current≦0.2mA≦50μA≦5μA≦0.5μA
≦50nA
OPTIONAL ACCESSORIES940 Alligator Clips792R Red Straight Test Pin793 Coil-Type Contact Pin
AC/DC
VAPODISP
HOLDMAXM I N DIFF
DUTY
%HzΩ
Extra fine test pin only φ0.5mm dia.
MODEL 792RRed Straight Test Pin(Optional Accessories)
φ0.5mm
Extra fine and elastic test
pin only 0.5mm diameter,
that is very suitable for
narrow point measurement.
Insulation coated bottom
to prevent incorrect
measurement.
Output Terminals
FEATURES● Smart Design for Easy of Use.● Fully line-upped function for useful measurements.●MAX / MIN, and Difference Measurements are available.
DCVoltage
ACVoltage
Resistance
Functions
Other Measurements
Digital Multimeters (Probe Tester)
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkDimensions WeightAccessories
::::::::
4000 count LCD 3 times / sec.Auto Ranging3V CR2032 Battery (x 1)CATⅢ 600V and EMC 179(H) x 28(W) x 20(D) mm 60g100-52 Test Leads (x 1)1006 Carrying Case (x 1)3V CR2032 Battery (x 1)
SK-4035
Digital Multimeters (Bench-Top DMM)
OPTIONAL ACCESSORIES660 AC/DC Clamp Adapter821 AC Clamp Adapter731 BNC Conversion Adapter 100-41 Test Lead Kit
100-62 Test Lead Set940 Alligator Clip793 Coil-Type Contact Pin
Bench-Type DMM with Output Terminals
FEATURES●Output terminals to connect and control the external
inspection equipments.●SK-4035 assures the accurate measurementby True RMS.● Comparator function useful for the quality check in the
production line.●Easy-to-use simple lay out keys Easy-to-read large display.
AC/DC
VAC/DC
ATRUERMS
RNGHOLDΩ COMP
Range400mV4V40/400/600V400mV4V40/400/600VRange400μA/4000μA40mA400mA10A400μA/4000μA40mA400mA10ARange400Ω4kΩ40kΩ400kΩ4MΩ40MΩComparator, Range Hold
Resolution0.1mV1mV10mV/100mV/1V0.1mV1mV10mV/100mV/1VResolution0.1μA/1μA10μA100μA10mA0.1μA/1μA10μA100μA10mAResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy
±0.3%rdg±2dgt
±1.0%rdg±5dgt(50Hz~500Hz)
Accuracy
±0.75%rdg±2dgt
±1.5%rdg±2dgt
±1.5%rdg±6dgt(50Hz~500Hz)
Accuracy±0.3%rdg±3dgt
±0.3%rdg±2dgt
±1%rdg±2dgt±3%rdg±4dgt
Input Impedance>100MΩ≒11MΩ≒10MΩ>100MΩ≒11MΩ≒10MΩVoltage Drop<0.05V / <0.25V<0.1V<0.6V<0.5V<0.05V / <0.25V<0.1V<0.6V<0.5VTest Current≦1.1mA≦110μA≦12.0μA≦1.2μA≦0.12μA≦0.12μA
SK-4033/ SK-4035SK-4035
Open Circuit Voltage2.4V
1.2V
:::::
:::
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyFuse
Dimensions WeightAccessories
4000 count LCD 10 times / secAuto / Manual RangingAC adapterF29 (3A/600V ) x 1, F30 (10A/600V ) x 1F31 (0.5A/250V) x 295(H) x 200(W) x260(D) mm, 1,140g100-57 Test Leads (x 1 set), AC AdapterSpare Fuses F31 (0.5A / 250V) x 1
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Resistance
Functions
20
Clam
p M
etersInsulation Testers / Earth Tester
Dig
ital Mu
ltimeters
An
alog
Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
SK-4033/4035
Waster
Suitable for theinspection automation
OutputTerminals
21
Analog Multitesters Index
Model
DC Voltage
AC Voltage
DC Current
AC Current
Resistance
Decibels
Continuity Test
Temperature
Battery Test
Overload Protection
(Internal resistance : 20kΩ / V)
0.3V
3V
12V
30V
120V
300V
1200V
(Internal resistance : 10kΩ/V)
12V
60V
300V
1200V
-60μA
3mA
30mA
600mA
12A
12A
2kΩ200kΩ2MΩ20MΩ●●●-●
SK-355
(Internal resistance : 20kΩ / V)
0.3V
3V
12V
30V
120V
300V
1200V
(Internal resistance : 10kΩ/V)
12V
30V
120V
300V
1200V
60μA
3mA
30mA
600mA
12A *1
-5kΩ
500kΩ5MΩ--●●-●
KF-32
(Internal resistance : 20kΩ / V)
0.3V
3V
12V
30V
120V
300V
1200V
(Internal resistance : 10kΩ/V)
12V
30V
120V
300V
1200V
60μA
3mA
30mA
300mA
--
5kΩ500kΩ5MΩ---●●●
KF-20
Shock Resistant Taut-band Meter is used for SK-355.
Taut-Band(band form spring)
Upper Boss
Tension Spring
Stopper
Pointer
Bottom Boss
Taut-Band method, suitable for
highly sensitive meter, has strong
shock resistant and frictionless
structure that can keep the meter
accuracy always stable.
In this method, moving coil is
supported by upper and bottom
taut-bands applying high tension
from both side. To maintain drop-
proof structure, taut-bands are
protected by two stoppers from
strong mechanical shock.
Taut-band Meter Pivot Meter
Pivot method is popular and
simple meter structure. As shown
in the illustration, pointed pivot is
simply supported by bearing
bush. However, it is weak against
mechanical shock. Pointed pivot
abrades away by the shock or
vibration during use, and causes
inaccurate meter indication.Pivot
Upper BossPointer
Bottom Boss
Bearing Bush
*1:Continuous measurement in 12A DC range is restricted up to 1 minute. More than 1 minute interval is necessary for the next measurement.
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
22
SK-355
Drop-proof Meter of Taut-Band AC / DC 12A Ranges
dBΩDC
AAC/DC
VAC
ADropProof
Range
0.3 / 3 / 12 / 30 / 120 / 300 / 1200V
12 / 60 / 300 / 1200V
60μ/ 3m / 30m / 600m / 12A
12A ( for 1 minute)
2k / 200k / 2M / 20MΩ-10 to +23 / 37 / 51 / 63dB
Temperature : -30℃ to +200℃ (±3% f.s. length)
(by optional Temperature Probe)
Continuity Tests : Buzzer sounds less than approx. 100Ω
InternalResistance
20kΩ/V
10kΩ/V
Tolerance
±3% f.s.
±4% f.s.
±3% f.s.
±4% f.s.
±3% f.s. length
*Optional temperature probe (810-02) is necessary for temperature measurement.
KF-20
Tough-designed Holster with Test Lead Holder
ΩDC
AAC/DC
V
Range
0.3 / 3 / 12 / 30 / 120 / 300 / 1200V
12 / 30 / 120 / 300 / 1200V
60μ/ 3m / 30m / 300mA
5k / 500k / 5MΩBattery Test : 1.5V (R20P / R14P / R6P)
1.5V 250mA (Hi Range)
1.5V 50mA (Low Range)
Temperature : -50℃ to +250℃ (±3% f.s. length)
InternalResistance
20kΩ/V
10kΩ/V
Tolerance
±3% f.s.
±4% f.s.
±3% f.s.
±3% f.s. length
*Optional temperature probe (810-02) is necessary for temperature measurement.
Analog Multitesters (Drop-Proof Tester)
Analog Multitesters
SPECIFICATIONSPower Supply
FuseDimensions WeightAccessories
:
::::
1.5V R6P or AA Battery (x 1)9V 6F22 or NEDA 1604 Battery (x 1)F15 (0.75A / 250V) x 1140(H) x 92(W) x 30(D) mm 280g100-57 Test Leads (x 1 set)1.5V R6P Battery (x 1)9V 6F22 Battery (x 1)Spare Fuse F15 (0.75A / 250V) x 1
SPECIFICATIONSPower SupplyFuseDimensions WeightAccessories
:::::
1.5V R6P or AA Battery (x 1)F12 (0.3A / 250V) x 1136(H) x 90(W) x 30(D) mm 215gHolster100-51 Test Leads (x 1 set)1.5V R6P Battery (built-in & spare) x 1 eachSpare Fuse F12 (0.3A / 250V) x 1
OPTIONAL ACCESSORIES810-02 Temperature Probe 100-41 Test Lead Kit100-62 Test Lead Set
940 Alligator Clips793 Coil-Type Contact Pin
940 Alligator Clips793 Coil-Type Contact Pin
940 Alligator Clips976 Carrying Case793 Coil-Type Contact Pin
OPTIONAL ACCESSORIES810-02 Temperature Probe100-41 Test Lead Kit100-62 Test Lead Set
SPECIFICATIONSPower SupplyFuseDimensions WeightAccessories
:::::
1.5V R6P or AA Battery (x 1)F15 (0.75A / 250V) x 1136(H) x 90(W) x 30(D) mm 215g100-64 Test Leads (x 1 set)1020 Carrying Case, 1.5V R6P Battery (x 1)Spare Fuse F15 (0.75A / 250V) x 1 (built-in)
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Resistance
Decibels
Other Measurements
DCVoltage
ACVoltage
DCCurrent
Resistance
Other Measurements
BATT.TEST
DC 12A measurement
Range
0.3 / 3 / 12 / 30 / 120 / 300 / 1200V
12 / 30 / 120 / 300 / 1200V
60μ / 3m / 30m / 600m / 12A
5k / 500k / 5MΩ(×1 / ×100 / ×1k)
Temperature : -50℃ to +250℃ Continuity Tests : Buzzer sounds less than approx. 30Ω
InternalResistance
20kΩ/V
10kΩ/V
Tolerance
±3% f.s.
±4% f.s.
±3% f.s.
±3% f.s. length
KF-32
AC/DC
V ΩDC
A
FEATURES● DC 12A measurement.● Temperature measurement (optional temperature probe
is necessary)
OPTIONAL ACCESSORIES810-02 Temperature Probe100-41 Test Lead Kit100-62 Test Lead Set
*Continuous measurement in 12A DC range is restricted up to 1 minute. More than 1 minute interval is necessary for the next measurement.*Optional temperature probe (810-02) is necessary for temperature measurement.
DC Voltage
AC Voltage
DC Current
Resistance
Other Measurements
Advantages of KF-32
Easy-to-readlarge character
DC12A RangesBig current can be measured in DC 12A range.
Scale plate with mirrorThe mirror to help the correct reading avoiding the reading error.
Test Leads withgold plated pins
MODEL 810-02
Temperature measurementTemperature can be measured by using optional temperature probe.
Clam
p M
etersInsulation Testers / Earth Tester
Dig
ital Mu
ltimeters
An
alog
Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
23
Automotive Testers Index (Digital Multimeters)
Model
Display Counts
Bargraph
DC Voltage
AC Voltage
DC Current
AC Current
Resistance
Frequency
Duty Cycle
Pulse Width
Continuity Test
Diode Test
Temperature
Revolutions Per Minute
Dwell Angle
Auto Ranging
Manual Ranging
MAX / MIN
Average
Range Hold
Difference
Display Hold
Current by Clamp Adapter
Dust Proof & Simple Water Resistant
Auto Power Save (Off)
9999
●999.9mV
9.999V
99.99V
600V
-999.9mV
9.999V
99.99V
600V
4000mA
10A
4000mA
10A
999.9Ω9.999kΩ99.99kΩ999.9kΩ
4MΩ40MΩ●●●●●●●●●●●●●●●●●●
KT-2020
2000
-200mV
2V
20V
200V
300V
2V
20V
200V
300V
20mA
20A
20mA
20A
200Ω2kΩ20kΩ
200kΩ2MΩ
20MΩ---●●-●-●●--●-●●-●
2000
-2V
20V
200V
300V
-2V
20V
200V
300V
30A
-30A
-200Ω2kΩ
20kΩ200kΩ2MΩ20MΩ---●-●●●●●--●-●●-●
24
Automotive Digital Multimeters
Clam
p M
etersInsulation Testers / Earth Tester
Dig
ital Mu
ltimeters
An
alog
Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
Accessories, Optional Accessories
The charge current of alternator can be measured just clamping.
Extremely versatile Automotive Digital Multimeter
FEATURES● Battery voltage measurement / rpm measurement (except
for rotary engine, diesel engine, and vehicle equipped with MSD or MDI systems.) / Injection pulse width measurement / Car alternator's charging current measurement (optional clamp adapter is necessary) / Sensor measurement / Air conditioner outlet temperature measurement, etc.
●MAX/MIN and Average Measurements.● Bar Graph Display.
KT-2020AC/DC
VAC/DC
A
BARGRAPH
APODISPHOLD
MAXM I N
RNGHOLDDIFF
HzΩDUTY
%PULSEWIDTH
DWELLANGLERPM AVE
RAGE
Range999.9mV9.999V99.99V600V999.9mV9.999V99.99V600VRange4000mA10A4000mA10ARange999.9 Ω9.999kΩ99.99kΩ999.9kΩ4MΩ40MΩFrequency, Duty Cycle, Pulse Width, Dwell Angle, RPM, Temperature, Continuity Test, Diode Test
MAX / MIN, Difference, Average, Range Hold, Display Hold, Auto Power Off
Resolution100μV1mV10mV100mV100μV1mV10mV100mVResolution1mA10mA1mA10mAResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy
±0.3%rdg±3dgt
±0.3%rdg±5dgt±2.5%rdg±5dgt(50Hz to 200Hz)
±2.5%rdg±5dgt(50Hz to 500Hz)
Accuracy±1.2%rdg±6dgt±0.8%rdg±4dgt±2.5%rdg±10dgt±1.2%rdg±3dgt
Accuracy±0.5%rdg±6dgt
±0.5%rdg±2dgt
±0.8%rdg±3dgt
±1.5%rdg±5dgt
Input Impedance≒16MΩ
≒10MΩ, 30pF
≒16MΩ
≒10MΩ, 30pF
Voltage Drop
0.03V/A
0.03V/A
Test Current≦0.46mA≦29μA≦2.9μA≦0.18μA≦0.12μA≦0.12μA
AC / DC Clamp Adapter(Optional Accessories)
RPM Sensor(Accessories)
RPM Sensor(Accessories)
Coil-Type Contact Pin(Optional Accessories)
Test Lead Kit(Optional Accessories)
For engine speed measurement of direct ignition engine that is equipped for the most of gas-powered car recently.
For engine speed measurement by clamping on the high tension cord.
Various measurement is possible by changing test pins.
MODEL 100-41 ●100-40 Lead Wires (1.6m)●766 Test Pipes●767 Test Pin (19mm,φ2mm)●792 Straight Test Pin (25mm,φ0.5mm)●769 L Type Test Pin●942 Alligator Clips●790 Test Hook (Inside Diameterφ10mm,Tip Diameterφ0.9mm)●791 Test Hook (Inside Diameterφ16mm,Tip Diameterφ0.9mm)
Contents
OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter100-41 Test Lead Kit100-62 Test Lead Set
Open Circuit Voltage2.7V DC
1.3V DC
Equipped with anUseful Carrying CaseEasy-to-carry plastic carrying case enables to pack KT-2020 and the all accessories together.
MODEL 653
Direct Ignition Coil Spark Plug
MODEL 654
φ0.4mmExtra fine test pin only 0.4mm diameter. It is suitable for coupler voltage measurement because it takes care not to scratch the object by spring structure.
944 Test Pin946 Battery Clip793 Coil-Type Contact Pin
DustProof
FireProof
Simple WaterResistant
::
::::::
SPECIFICATIONSDisplaySampling Rate
Range SelectionPower SupplyFuseDimensions WeightAccessories
9999 count LCD (Numerical) 4 times / sec(Bargraph) 20 times / secAuto / Manual Ranging9V 6F22 or NEDA 1604 Battery (x 1)F17(10A/250V) x 1 150(H) x 75(W) x 34(D) mm, 252gHolster, 100-46 Test Leads (x 1 set)653 RPM Sensor (for Direct Ignition)654 RPM Sensor (for High Tension Code)818-02 Temperature Probe943 Alligator Clip, 1024 Carrying Case9V 6F22 Battery (Installed) x 1F17 Spare Fuse (10A/250V) x 1
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Resistance
Other MeasurementsFunctions
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
25
Automotive Digital Multimeters
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Other MeasurementsFunctions
Resistance
Range200mV2V20V200V300V2V20V200V300VRange20mA
20A
20mA
20A
Range200Ω2kΩ20kΩ200kΩ2MΩ20MΩOpen Circuit Voltage : approx. ≦0.43VRPM, Continuity Test, Diode Test,Current by Clamp Adapter, Range Hold, Display Hold, Auto Power Save
Resolution0.1mV1mV10mV100mV1V1mV10mV100mV1VResolution10μA
10mA
10μA
10mA
Resolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy
±1.2%rdg±2dgt
±2.3%rdg±7dgt
Accuracy±1.0%rdg±4dgt0 to 10.00A±1.5%rdg±2dgt10.01 to 20A ±2.5%rdg±4dgtt±2.0%rdg±8dgt0 to 10.00A±2.0%rdg±7dgt10.01 to 20A±3.0%rdg±10dgtAccuracy
±1.5%rdg±4dgt
±1.8%rdg±4dgt±5.0%rdg±4dgt
Input Impedance≧100MΩ
≒11MΩ
≒10MΩ
≒11MΩ
≒10MΩ
Voltage Drop≦0.5V
<0.5V
<0.5V
Test Current≦0.4mA≦0.2mA≦30μA≦3μA≦0.3μA≦0.03μA
Motorcycle Multimeter
AC/DC
VAC/DC
ARNGHOLD
ΩFEATURES● RPM, 20mA and 20A DC / AC, and Continuity Tests.● 200A DC / AC measurements by optional 660 Clamp Adapter.
SPECIFICATIONSDisplaySampling RateRange SelectionPower Supply FuseCE MarkDimensions WeightAccessories
:::::::::
2000 count LCD, Maximum Reading 1999 2 times / secAuto / Manual Ranging1.5V R6P or AA Batteries (x 2)F12 (0.3A / 250V) x 1, F18 (15A / 250V) x 1CATⅡ 300V and EMC160(H) x 75(W) x 34(D) mm 180g100-57 Test Leads (x 1 set) 650 RPM Sensor (x 1), 940 Alligator Clips (x 1 set) 995 Carrying Case (x 1), 1.5V R6P Batteries (x 2) Spare Fuses F12 (0.3A / 250V) &F18 (15A / 250V), x 1 each
DISPHOLD
OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips
944 Test Pin946 battery Clip793 Coil-Type Contact Pin
APS
RPM
Focusing on Easy of Use Digital Tachometer.
FEATURES●Quick and Easy Measurement.●Measurable with Various Types of Engines. (except for rotary engine, diesel engine, and vehicle equipped
with MSD or MDI systems.)
SK-8401 DIGITAL TACHOMETER
SPECIFICATIONSDisplayPower Supply CE MarkDimensions WeightAccessories
::::::
Maximum Reading 9999 1.5V R6P or AA Batteries (x 2)CATⅠ 1000V and EMC148(H) x 83(W) x 33(D) mm 180g652 RPM Sensor (x 1)995 Carrying Case (x 1)1.5V R6P (AA) batteries x 2
RPM
SPECIFICATIONSDisplaySampling RateRange SelectionPower Supply FuseDimensions WeightAccessories
::::::::
2000 count LCD, Maximum Reading 1999 2 times / secAuto / Manual Ranging1.5V R6P or AA Batteries (x 2)F19 (25A / 250V) x 1160(H) x 75(W) x 34(D) mm 180g100-57 Test Leads (x 1 set) 818-02 Temperature Probe (x 1)940 Alligator Clips (x 1 set)991 Carrying Case (x 1), 1.5V R6P Batteries (x 2)Spare Fuse F19 (25A / 250V) x 1
OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips
944 Test Pin946 battery Clip793 Coil-Type Contact Pin
OPTIONAL ACCESSORIES650 RPM Sensor (for High Tension Cord)
DWELLANGLE
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Other MeasurementsFunctions
Resistance
Range2V20V200V300V2V20V200V300VRange
30A
30A
Range200Ω2kΩ20kΩ200kΩ2MΩ20MΩOpen Circuit Voltage : approx. ≦0.43VRPM, Dwell Angle, Continuity Test, Temperature,Current by Clamp AdapterRange Hold, Display Hold, Auto Power Save
Resolution1mV10mV100mV1V1mV10mV100mV1VResolution
0.1A
0.1A
Resolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy
±1.2%rdg±2dgt
±2.3%rdg±8dgt
Accuracy0 to 10.00A±1.5%rdg±4dgt10.01 to 30A ±2.5%rdg±4dgt0 to 10.00A±1.5%rdg±4dgt10.01 to 30A±2.5%rdg±7dgtAccuracy
±1.5%rdg±4dgt
±1.8%rdg±4dgt±5.0%rdg±4dgt
Input Impedance≒11MΩ
≒10MΩ
≒11MΩ
≒10MΩ
Voltage Drop
≦0.5V
≦0.5V
Test Current≦0.4mA≦0.2mA≦30μA≦3μA≦0.3μA≦0.03μA
Automotive Multimeter
AC/DC
VAC/DC
ARNGHOLD
Ω
FEATURES● RPM, Dwell Angle, Temperature, 30A DC / AC.● 200A DC / AC by optional 660 Clamp Adapter.
DISPHOLD
rpmRange100 to 9999 rpmDisplay Hold, Auto Power Off
Resolution1 rpm
Accuracy±0.2%rdg±10rpm
Maximum. Input10000 rpm
APS
DISPHOLD APO
RPM
Digital Tachometer
Functions
Quick and Easy Measurement
Measurement ofDirect Ignition Engine
Use 652 RPM Sensor(provided)
Measurement ofHigh Tension CodeType Engine
Use 650 RPM Sensor(option)
SHIFT DH
SK-8401
DISPLAYHOLD POWER
1 2 HI(1Sec<)
DIGITALTACHOMETER
Direct ignition coil
MODEL 652
SHIFT DH
SK-8401
DISPLAYHOLD POWER
1 2 HI(1Sec<)
DIGITALTACHOMETER
MODEL 650
Spark Plug
26
Clam
p M
etersInsulation Testers / Earth Tester
Dig
ital Mu
ltimeters
An
alog
Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
φ20mm
ConductorDiameter
Low Current DC Clamp Meter
Quick and Easy Dark Current Measurement Just Clamping-On
FEATURES●Automatic Zero-Adjustment function to adjust LCD
indications into 0±1 digit when powered on.● Stable LCD reading even in low current.● Shielded clamp core prevents external noise or effect
of external magnetic field.
SK-7830
DC
4000mADC
40A/200A DIFF AUTOZERO APODISP
HOLD
DCCurrent
Functions
Accuracyfrom 5mA0A to 100A101A to 200A
±1.5%rdg±5dgt
±3.0%rdg±5dgt
Range4000mA40A200ADifference, Power-on Initialize, Display Hold, Auto Power OFF
SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:::::::::
4000 count LCD, Maximum reading 405064 times / sec (Display : 1 time / sec) Manual (4000mA), Auto (40A / 200A)φ20mm Max. 1.5V R6P or AA Batteries (x 2) CATⅢ300V, CATⅠ600V and EMC203(H) x 61(W) x 30(D) mm230g 1011 Carrying Case (x 1)1.5V R6P Batteries (x 2)
O2 Sensor Checker
Deterioration level of O2 sensor can be checked easily by bar-graph
FEATURES●Deterioration level of O2 sensor can be checked easily
by bar-graph● Rich, Lean, Average voltages and Cycle are displayed
respectively.● Simulated sensor signal output is available.
SK-8402 O2 SENSOR CHECKER
APODISPHOLD
DCVoltage
Functions
Resolution
1mV
10mV
Accuracy0 to 200mV:±1.5%rdg±10dgt 201 to 999mV:±1.5%rdg±5dgt ±1.5%rdg±5dgt
Range
999mV
6.00VDisplay mode changing, Simulation Test, Display Hold, Auto Power Off
Car Measurement with SK-7830
Connection image
Bar-Graph Display
Dark Current MeasurementDark Current : mA-level low current that is used after turning off the engine by such as car security system or audio settings back-up. Too much dark current causes battery runs out, but its measurement was difficult. SK-7830 solved this problem and make it quick and easy.
Leave the engine turned off for about 15 minutes. All electric components (headlights or lamps) must be turned off. Clamp-on a minus cable of car battery. Read the measurement value. If it is higher than the specified value, check once again.
1
1
2
3
Car Alternator's Charging CurrentMeasurementCar Alternator : Engine generator that outputs DC electricity. Measuring its charging current is effective to find the trouble that might cause battery runs out or battery damages.
Clamp B-terminal cable from car alternator. Start the engine. Alternator has no problem if 20A to 40A is displayed first, and then it slowly becomes lower.
1
2
3
mV
RICH
TEST Z
APO
GOOD CHECK BAD
CHECKreplacement
recommended( )
mV
RICH
TEST Z
APO
GOOD CHECK BAD
BADreplacement
required( )GOOD
(No problem)
mV
RICH
TEST Z
GOOD CHECK BAD
APO
SK-8402
ECU in vehicle sideO2sensor
Test lead
Check harness
Connecting couplerfor O2 sensor side
Connecting couplerfor ECU side
POWER(1Sec<)
S (1Sec<)
(Test)
O2 SENSOR CHECKER
DHT5T1Z
RICH LEANDISPLAYTEST
SK-8402
TEST SEL
C
mV
AUTO DH
RICH
TEST Z T1 T5 S
AVGLEAN
APO
GOOD CHECK BAD
Yello
w
Yello
w
Blac
kBl
ack
Red
Red
Black Red
DC
V
SPECIFICATIONSDisplay
Sampling Rate
Range SelectionPower SupplyDimensions WeightAccessories
:
:
:::::
(Numerical) 999 count LCD,(Bargraph) 13 segments500 times/second(LCD : 1 time/second in stand-by mode)Auto Ranging1.5V R6P or AA Batteries (x 2)148(H) x 83(W) x 33(D) mm 220g100-65 Test Lead (x 1 set) 911Check Harness (x 1)947B Black Alligator Clip (x 1)795 Test Pins: Red & Black (x 1 set)1030 Carrying case (x 1)1.5V R6P Batteries (x 2)
SK-8402 is the O2 Sensor Checker for the O2 sensor of Zirconia, Titania 1V/5V. SK-8402 can not check deterioration judgment of A/F (air-fuel ratio) Sensor or Rear O2 Sensor.
Deterioration level of O2 sensor can be checked easily by bar-graph.
27
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
Advantages of SK-8301
Triaxial ELF Magnetic Field Meter
True RMS! High Performance!
APOMAXM I N
AVERAGE
FEATURES●Accurate Measurement by Triaxial Sensor.● True RMS.
SK-8301 TRIAXIAL ELF MAGNETIC FIELD METER
Range20.00μT200.0μT200.0mG2000mGMAX/MIN, Average, Display Hold, Auto Power Off
Resolution0.01μT0.1μT0.1mG1mG
Accuracy±2%rdg±5dgt (50/60Hz)±5%rdg±5dgt (40Hz to 1kHz)±2%rdg±5dgt (50/60Hz)±5%rdg±5dgt (40Hz to 1kHz)
Maximum. Input
200.0μT
2000mG
::::::::::
SPECIFICATIONSDisplayOperating PrincipleSampling RateRange SelectionRectificationPower SupplyCE MarkDimensions WeightAccessories
2000 count LCD, Maximum Reading 2000 Triaxial True RMS (X, Y, Z)2 times / secondAuto RangingTrue RMS1.5V R6P or AA Batteries (x 2)CATⅠ600V and EMC148(H) x 83(W) x 33(D) mm, 220g1015 Carrying Case1.5V R6P Batteries (x 2)
μTmeasurement
mGmeasurementFunctions
DISPHOLDμT mG
Electromagnetic comes from mixed directions if multiple sources are existing. Even in such field., SK-8301 can measure correct magnetic flux density by its triaxial (X, Y, Z) sensor.
X:Right and leftY:Back and forthZ:Up and Down
Y
X
Z
SK-8301
TRIAXIAL ELFMAGNETIC FIELD METER
Y
X
Z
REC DH
DISPLAYHOLD POWERMAX / MIN
AVG
In the field of multipleelectromagnetic sources
Accurate Measurement by Triaxial Sensor
True RMSDue to large distortion contained in electromagnetic wave, measurement result by average rectification meter should be incorrect. SK-8301 measures in True RMS and the measurement result is always accurate.
Digital Thermometer
Wide Range of Temperature Measurement from -99.9°C to 1300°C (-148°F to 2372°F)
*Compensation Lead : Conventional type (-20℃ to 90℃) 1.5m
Optional Temperature Probes for SK-6850 [TYPE K (CA)]MODEL
817-01
817-03
817-17
817-19
817-24
817-25
Dimensions (Sensor)
3.2φ×250mm
5φ×500mm
1.6φ×150mm
3.2φ×150mm
4.5φmm
3.2φ×150mm
Application
For Liquid Temperature Measurement
For Liquid Temperature Measurement
For Internal Temperature Measurement like food or chemical materials and Liquid Temperature Measurement
For Internal Temperature Measurement like food
Surface Temperature Measurement
For Air Temperature Measurement like Air Conditioner
Measurement Range
-50℃ to 800℃-50℃ to 1150℃-50℃ to 600℃-50℃ to 750℃0 to 600℃0 to 200℃
APOMAXM I N
AVERAGE
FEATURES●MAX/MIN and Average measurements are possible.● Temperature Sensor : K-type thermocouple.● Long-Time Measurement for 1000 Hours. (For alkaline cells)● Centigrade (℃) and Fahrenheit(°F) are Selectable.● Various Types of Optional Temperature Sensor.●Double-molded rubber to get steady grip during
the measurement. ● Easy-to-Read Large Display.
Range-99.9 to 199.9190 to 1300-148 to 2372MAX/MIN, Average, Display Hold, Auto Power Off
Accuracy±0.5%rdg±0.8℃±0.5%rdg±1℃±0.5%rdg±2°F
Resolution0.1℃1℃1°F
Maximum Input
1300℃
2372°F
℃ (Auto-ranging)
°FFunctions
OPTIONAL ACCESSORIES817-01 to 817-25 Temperature Probes732 Miniature Connector Conversion Plug
SPECIFICATIONSDisplayTemperature SensorSampling RateRange SelectionPower SupplyCE MarkDimensionsWeightAccessories
:::::::::
Maximum reading 9999Thermocouple K Type2 times / secondAuto Ranging1.5V R6P or AA Batteries (x 2)CE marking compliant148(H) x 83(W) x 33(D) mm185g818-02 Temperature Probe995 Carrying Case (x 1)1.5V R6P Batteries (x 2)
Dimensions of Temperature Probes
φ14
98
φ1.6 SUS316
150
φ3.2 SUS316
150
φ14
98
225
φ12
500 125
φ15φ5.0
250 109
φ15φ3.2 φ3.2 SUS316
150
φ14
98
MODEL817-01
817-03
817-17
MODEL817-19
817-24
817-25
Tip Form Dimensions Tip Form Dimensions
φ4.5
1.2
2~3 5
Unit : mm
DIGITAL THERMOMETER
28
Test Leads / Test Pins
100-41 Test Lead Kit
Connect Test Plugs and Test Pipes of 100-40 Lead Wire, and connect 3 kinds of Test Pin or 2 kinds of Test Hook.
Test Plug of100-40 Lead Wires
767 / 769 / 792 Test Pin790 / 791 Test Hook766 Test Pipes
Applicable ModelsSK-7682 / 7718 / 7719 / 7720 / 7722 / 7706 / 7707 / 7708 / 7615 / 7625 / 7640 / 7810
7815 / 6161 / 6163 / 6150 / 4033 / 4035 / 355 / 6166 / 6167KU-2602 KF-32 / 20 KT-2020
Coil-Type Contact Pin
Extra fine test pin. It takes care not to scratch the object by spring structure.
Applicable ModelsSK-7660 / 7661 / 7682 / 7718 / 7719 / 7720
7722 / 7706 / 7707 / 7708 / 7602 / 76037615 / 7625 / 7640 / 7810 / 7815 / 78207825 / 6161 / 6163 / 6150 / 6500 / 65554033 / 4035 / 6592 / 355 / 6166 / 6167
KU-2602 KF-32 / 20 KT-2020
Newly-developed test lead for our mini-clamp meter series.+ / - integrated connector that can hardly pulled out during measurement.
Test Leads
Applicable ModelsSK-7660 / 7661 / 7602 / 7603 / 7820 / 7825
Connector
This test pin is suitable for narrow point measurement. That can measure with inserting the pin to the backside of insulation coupler of the car.
Test Pin
Applicable ModelsKT-2020 / 6166 / 6167
Major test lead for our products. Gold-plated pins assures long-lasting contact.
Extra fine test pin only 0.5mm diameter. It is very suitable for narrow point measurement. Use it with connecting to 100-40 test plug.※Difference from 792 straight test pin : 795 can connect to 100-40 directly without 766 test pipes.
Gold platedpins
100-57 Test Leads
Applicable ModelsSK-7682 / 7718 / 7719 / 7720 / 7722 / 7706
7707 / 7708 / 7615 / 7625 / 7640 / 61616163 / 6150 / 4033 / 4035 / 355 / 61666167
φ0.4mm
φ0.4mm
Big alligator clip can hold the battery terminal firmly. It can operate the instrument without putting it.
Battery Clip
Applicable ModelsKT-2020 / 6166 / 6167
100-40Lead Wire
766RRed Test Pipe
942BBlack
Alligator Clips
792RRed Straight
Test Pin
Test Lead SetLead WiresRed Test PipeRed Straight Test PinBlack Alligator Clip
Models100-40766R792R942B
Applicable ModelsSame as the models for 100-41
Test Lead SetCombination of useful components from 100-41.
Test PipesMax. Voltage : 1000VMax. Current : 10A
Alligator ClipsMax. Voltage : 1000VMax. Current : 20AJaw Opening : 20mm
Test Pin
100-40Lead WiresWire Length : 1.6mMax. Voltage : 1000VMax. Current : 10A
1002Carrying case
Straight Test PinTest HookL Type Test Pin
15mm
Max. Current : 1A Max. Voltage : 100V
Test Pin
Applicable ModelsSK-8402 / 100-40
Max. Current : 1A Max. Voltage : 100V
Straight Test Pin
φ0.5mm
Extra fine and elastic test pin only 0.5mm diameter, that is very suitable for narrow point measurement. Insulation coated bottom to prevent incorrect measurement.
Applicable ModelsSK-6592 / 100-41
*Only red pin is available for SK-6592.
Max. Current : 1A Max. Voltage : 100V
φ0.5mm
Clam
p M
etersInsulation Testers / Earth Tester
Dig
ital Mu
ltimeters
An
alog
Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
riesC
lamp
Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g M
ultitesters
Au
tom
otive T
estersO
ther T
estersA
ccessories
*Red and black parts are contained except for 790 and 791.
Test Lead KitLead WiresTest PipesTest PinsL Type Test PinsTest Hook for Dark CurrentTest Hook for Dark CurrentStraight Test PinsAlligator Clips
Models100-40766767769790791792942
ModelsLength of PinInside DiameterTip DiameterMax. VoltageMax. Current
76719mm
-φ2mm1000V10A
79225mm
-φ0.5mm100V1A
76915mm
-φ0.9mm1000V1A
79068mmφ10mmφ0.9mm100V1A
79174mmφ16mmφ0.9mm100V1A
29
821 AC Clamp Adapter
Temperature Probe
Clamp Adapter
821 assures the accurate measurement by true RMS. It can connect not only to the recorder by BNC connector but to the banana input instrument by use of bundled conversion adapter.
731BNC Conversion Adapter
Conversion Adapter
MeasurementAC 0 to 400A
Applicable ModelsKU-2602SK-6161 / 6163 / 6150 / 4033 4035
880 Line Separator
Line Separator
810-02 Temperature Probe
Applied for the testers that have temperature measurement function.
818-02 Temperature Probe
Measurement-50℃ to 100℃
Applicable ModelsKU-2602KT-2020SK-6167 / 6850
818 Temperature Probe
AC / DC Clamp Adapter
660 can measure up to 400A AC / DC by using in combination with Digital Multimeters that can measure 400mV AC / DC.
MeasurementAC 0 to 400ADC 0 to 400A
Applicable ModelsKU-2602SK-6161 / 6163 / 6150 / 4033 4035 / 6166 / 6167KT-2020
732 Miniature Connector Conversion Plug732 can convert miniature connector to banana plug. ※K-type temperature sensor only.
731 can convert BNC connector to banana plug.
Applicable ModelsKU-2602SK-6850
Alligator Clips
Applicable ModelsSK-7660 / 7661 / 7718 / 7719 / 7720 / 7722 / 7706 / 7707
7708 / 7602 / 7603 / 7615 / 7625 / 7640 / 7810 / 78157820 / 7825 / 3500* / 3502* / 6161 / 6163 / 61506500 / 6555 / 4033 / 4035 / 6592 / 355 / 6166 / 6167
KU-2602 KF-32 / 20
*Only red pin is available for SK-3500 / 3502.
Alligator Clips
Applicable ModelsKU-2602SK-6161 / 6163 / 6150 / 4033 / 4035821 AC Clamp Adapter
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
Standard Accessories (excerption)
Test Leads100-03100-34100-36100-36 (Red)100-40100-40-1100-40-2100-44100-45100-46
100-48100-50100-51100-52100-57100-61100-63100-64100-65
Carrying Case976978983985985-02988991995100010041005
10061007101110121013101510161020102210241030
FuseF12 (0.3A / 250V)F13 (0.5A / 250V Non-arcing)F14 (0.5A / 250V)F15 (0.75A / 250V)F16 (15A / 250V)F18 (15A / 250V)F19 (25A / 250V)F22 (0.5A / 600V)
F23 (1A / 600V)F24 (3A / 600V)F25 (15A / 600V)F26 (1A / 600V)F29(3A / 600V)F30(10A / 600V)F31(0.5A / 250V)
Alligator Clips940942942B (Black)
943945B (Black)947B (Black)
Measurement-50℃ to 250℃
Applicable ModelsSK-355KF-32 / 20
Measurement-50℃ to 160℃
Applicable ModelsSK-7720 / 7722 / 7706
Applicable ModelsSK-7660 / 7661 / 7718 / 7719 / 7720 / 7722
7706 / 7707 / 7708 / 7600 / 7602 / 76037615 / 7625 / 7640 / 7810 / 78157820 / 7825
821 Clamp Adapter
Mark Descriptions
30
CapacitanceCapacity of electronic capacitor (electrostatic capacity) is measurable in F (farad) unit.
Diode Test Diode test is possible measuring its forward and reverse side.
TemperatureTemperature is measurable using the temperature probes.
AC CurrentAC Current measurement is possible.
AC
A
DC CurrentDC Current measurement is possible.
DC
A
FrequencyFrequency measurement is possible.Hz
Decibel (low-frequency output)Low frequency output like audio amplifier is measurable in dB (decibel) unit.
dB
Pulse WidthWaveform pulse width for logic or switching controls are measurable in ms (milli-second) unit.
PULSEWIDTH
Dwell AngleElectricity time for automobile engine is measurable converting into an angle.
DWELLANGLE
Revolutions Per MinuteRPM of automobile engine is measurable.
RPM
AC VoltageAC Voltage measurement is possible.
AC
V
Duty CycleThe duty cycle of repeating waveform is measurable and indicated in a percentage basis(%).
DUTY
%
DC VoltageDC Voltage measurement is possible.
DC
V
ResistanceResistance measurement is possible.Ω
Continuity TestThe buzzer sounds when the measuring object is electrically conducting.
Low ResistanceLow Resistance measurement is possible.Ω
LOW
Magnetic FieldMagnetic Field measurement is possible.
TRUERMS
True RMS (True root-mean-square value)True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
APO Auto Power OffPower is automatically turned off when a certain period of time has elapsed after the power on. Some models are enabled to cancel this function.
APS Auto Power SaveDisplay is automatically turned off and into power save condition when a certain period of time has elapsed after the power on. Some models are enabled to cancel this function.
Simple WaterResistant
Simple Water ResistantWater-Resistant case is used to protect the tester from water damage.
DATAMEMO
Data MemoryMeasurement data can be saved in internal memory.
AUTOZERO
Power-On InitializeAutomatic Zero-Adjustment function to adjust LCD indications into 0±1 digit when powered on.
DropProof
Drop ProofAnti-shock structure enables to protect the tester from the strong shock by the 1-meter-dropping-off.
OUTPUT
Output TerminalAn output terminal connectable to the Oscilloscopes or Recorder is available.
DustProof
Fireproof
Dust ProofDust-proof case is used to protect the tester from dust damage.
LPF Low Pass FilterFrequency signals higher than the specified cutting-off frequency are intercepted.
Backlight LCDUseful for easy reading even in dark areas.
COMPComparator (Comparing function)Buzzer sounds when the input value is beyond the specified high and low limits.
DISPHOLD
Display HoldEnables to hold the indicating values on LCD. Useful to note down the measurement values.
MAXM I N
MAX / MINThe minimum and maximum of the measurement values are measurable and indicates on LCD.
AVERAGE
AverageThe average of the measurements value for a certain period of time is measurable.
PEAKHOLD
Peak HoldThe Peak current value in a certain period of time is measurable and indicates on LCD.
DIFF DifferenceA certain measurement value is stored and converted into zero. The difference between measuring value and stored value is indicated with proceeding measurements.
RNGHOLD
Range HoldEnables to hold the ranges when the Current or Voltage values are unstable and difficult to read.
BARGRAPH
BargraphBar Graph is available on LCD. Zoom-up function is available for some models.
Measurement Items
Measurement Functions
Battery TestBattery voltage and its condition are tested applying a certain current to the tester.
BATT.TEST
Fireproof CaseThe fireproof case protects the instrument inside from fire.
μT mG
www.kaise.com
DISTRIBUTOR
70-0201-0000-4 1004
422 Hayashinogo, Ueda City, Nagano Pref., 386-0156 Japan
Telephone : +81-268-35-1601 Fax : +81-268-35-1603
E-mail : [email protected]