SEN Plus ED.03
Reliable LV switchgear solutions The heart of your business
GEPower Protection
GE imagination at work
1
SEN PlusM
arkets
Test and standards
Dust and waterproof
Internal form of separation
Compact
Smart and simple design
Durable surface protection
Maintenance free busbar system
Future investment
Why SEN Plus?
IP54
BoundarylessFour Pole - KEMA type tested assemblies up to 6300A for powerdistribution and control as per IEC 61439-1 /EN 60439-1 and IEC/TR 61641 for internal arcing.Enables a boundaryless environment
Production environmentCertified to IEC 60529-1 for IP30 - IP54 arrangements.Enables the installation of the equipment in a range of environmental conditions
Safe modificationsUp to Form 4B as per IEC 60439-1Enables safe modification under energised conditions
Functional floor spaceIncreases functional floor space in building services
Fast deliveryFast and efficient assembly techniques secures fast deliveries and customer satisfaction.Secures fast deliveries
ResistantProduct design and epoxy powder coating provides a shock and shock resistant design.Minimises damage during installation
Lower investmentCentral design and ongoing testing to the latest standards.Lowers investment costs
Environmental benefitsFully RoHS compliant and control of waste and packaging reduces manufacturing processes, additional power monitoring features provide energy saving opportunities.
Commercial• Small and large offices• Warehouses• Shopping malls• Schools• Hospitals• Airports
Industrial• Printing • Machinery• Pharmaceutical• Automotive, paper & pulp• Chemical industry• Marine• Oil & Gas
Utilities• Water treatment plants• Waste management• Energy distribution
(Electricity and Gas)• Telecommunications• Cable providers• Public transport
The SEN Plus system has been designed from the outset based on customer requirements. The result is a product that offers unrivalled flexibility and user safety, backed up by comprehensive testing and support for many specific applications:
Buildings, machineryand processes
Flexible system to suit your requirements
SEN Plus system can meet the most demanding
requirements from high current applications up to 6300A down to
motor control applications for a few kW. Furthermore the system is available in
different configurations, which include:• Fixed, plug-in, withdrawable
• Front or rear acess• Distribution• Motor control
The system offers varying forms of separation up to Form 4B to IEC 60439-1 and ingress
protection from IP30 to IP54.
2 3
Technical dataSafe
ty
Electrical dataRated operational voltage Ue 690V AC / 600V DCRated frequence f 50 / 60HzRated impulse voltage / Overvoltage category Uimp 8kV / IIIRated current horizontal busbars up to 7800APeak withstand current Ipk up to 220kAShort time withstand current Icw up to 100kA Rated current vertical busbars 850 / 1200 / 1550 / 1900A
Mechanical dataModularity 1 E = 25mmDimensions Height 2000 / 2200mm Depth 600 / 800 / 1200mm Width 400 / 500 / 600 / 800 / 1000 / 1200mmDegree of protection IP30 up to IP54Form of internal separation up to Form 4bColour RAL 7035 Epoxy-polyester
StandardsType tested IEC 61439-2 , IEC 60439-1,
DIN EN 60439-1, VDE 0660 Teil 500, BS EN 60439-1
Internal arc tests IEC/TR 61641Seisimic withstand UBC
Complete system controlAs a manufacturer of various types of protective equipment GE offers a complete choice, which includes:• Miniature, Moulded Case & Air Circuit Breakers• Fuses & Switch Disconnectors• Variable Speed Drives & Contactors
Communication and control increasingly forms part of a system – data exchange via Profibus or Modbus is available for most components, to ensure a homogeneous setup.
Environmental considerationsThe care of the environment in which we live and work is playing an increasinglyimportant place in the considerations for the purchase of electrical equipment.SEN Plus has taken this into account through every aspect of its design.
Manufacturing processThe manufacturing plants are certified to ISO 14001 eliminating waste and packaging.Six Sigma and ISO 9001 ensure that waste is eliminated through highest efficiency in processing and design. SEN Plus is fully RoHS compliant.ComponentsThe steelwork used is mild steel and does not contain harmful Cadmium. The frames are zinc plated to prevent corrosion and ensure the product has a long life. OperationYou can manage your impact upon the environment while operating SEN Plus by using the various accessories that can improve energy efficiency, like usage of variable speed drives, kWh meters or intelligent motor management modules. A range of software is available to get the highest grade of efficiency while using such products.
Technical data
SafetyThe combination of SEN Plus and the new EntelliGuard™ Air Circuit Breaker excel in terms of safety – both for personnel as well as system protection.
Limitation of internal arc faults has been independently tested to ensure compartmentalisation of the functional areas to limit the fault to the point of origin.The switchboard has been independently Type Tested to IEC 61439.With a fault withstand rating of 100kA the system is equipped to deal with large faults.
SEN Plus SEN Plus
4
SEN Plus
5
SEN PlusBenefi tsBe
nefi t
s
Great benefitsRigid frame construction• Non welded self supporting
construction • Doors and covers
in 2mm sheet steel
Seismic proofed design• Suitable for installation across the world
under extreme seismic conditions• UBC zone 4 requirements
Simplified cabling• Optimized terminal bar arrangement
for large cable cross sections
Internal form of separation• Panel clearly structured into the 3
different zones - equipment zone, cable zone and busbar zone
• Up to form 4 separation possible
Easy commissioning at site • Main busbars links are accessible
from the front
For your safety• Finger proof shrouds and
barriers prevent accidental contact with busbars
• Door locks according to yoursafety requirements
Freq(HZ)
TRS(g)
F(H
1.00 0.11 71.12 0.19 81.26 0.26 81.41 0.41 11.59 0.41 11.78 0.66 12.00 0.94 12.24 1.17 12.52 1.44 12.83 1.70 23.17 1.93 23.56 2.23 24.00 2.45 24.49 2.45 35.05 2.46 35.66 2.55 46.35 2.49 4
High level in the Front-to-Back & Vertical direction: Vertical reference
File with TRS: tChannel: VertA
Damping = 4%
Resp
onse
[g]
Frequency [HZ]
10
10 100
1
10.1
Optimum accessibility• 135/180° door opening angle
Complete system integration • Equipped with the complete range of
IEC 60947 tested components
1. Equipment zone2. Cable zone3. Busbar zone
1
2
3
6
SEN Plus
7
SEN PlusBenefi tsBe
nefi t
s
Modularity• Increased stacking density in the equipment
zone due to 25mm module steps in vertical busbar shrouds
Ready for 6400A• Power Center can be equipped with the
EntelliGuard™ Air Circuit Breaker up to 6400A• Full range available in only 3 frame sizes
Short-circuit rating up to 100kA • Circuit breaker and busbars are
available for 100kA, 1 sec
State of the art electronic trip • With integrated ampere- and powermeter• In 4 different versions to cover all needs
Communication• Modbus and Profibus are available to
integrate industrial automation and communication requirements
VPS modules • For modular components on DIN-rails• Mounting plates
All for your safety
EPOS- DP
Profibus BP
ethernet TCP/IP
acyclic data exchange
cycl
ic d
ata
exch
ange
conf
igur
atio
n
process control system
bis 3-7-DP ES S-DP
win B GOPC-server
MACompact design• Small footprint with two breakers
in one column
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
Enveloppe 2000AIcu=Ics
AvailableInterruption tiers
Enveloppe 6400AIcu=Ics
Enveloppe 4000AIcu=Ics
Easy and safe operation • A special mechanism allows full
operation of the module while the door is closed. This ensuresthe maximum safety level forthe operator.
SET UP
METER
STATUS
EVENTS
SET UP
METER
STATUS
EVENTS
8
SEN Plus
9
SEN PlusBe
nefi t
sBenefi ts
It´s all about reliability
Operator protection • All operations are possible when the doors are closed• Enclosure is tested under arc fault conditions
High short-circuit value of the vertical riser system • Fully rated 3 and 4 pole system
Fast and easy cabling• Pre-configured copper links, directly to the device or via
terminal bars• Cable compartment can be 200, 400 or 600mm wide
Distribution and Control applications in one column• Standard adapters in 2 different
heights ensure combinations of standard 3 and 4 pole fuse loadbreak switch units and motor starters in one column
For your safety• Short-circuit proof and fatigue
free self-aligning stabs secure a high safety level during operation
10
SEN Plus
11
SEN Plus Standard applications
Motor Control Center - Fully withdrawable modules
Motor Control Center - Plug-in modules
Motor Control Center - Fixed modules
Functions with circuit breakersMax. load
in (kW)Motor starter DOLModule size in (E)
Motor starter ReverseModule size in (E)
Motor starter Star/DeltaModule size in (E)
at 400 Vac at 690 Vac at 400 Vac at 690 Vac at 400 Vac at 690 Vac11 12 1215 1230 5 12 8 12 1037 555 12 12 1275 12 12 1290 24 24
110 30 30132 18 12160 24200 30220 24 30 24250 24 36 36
Functions with circuit breakers at 400 and 690 VacFeeder (3 pole)
at 400 VacFeeder (4 pole)
at 400 VacFeeder (3 pole)
at 690 VacFeeder (4 pole)
at 690 VacCurrent
in (A)Module size
in (E)Current
in (A)Module size
in (E)Current
in (A)Module size
in (E)Current
in (A)Module size
in (E)160 8 160 8 160 8 160 8250 10 250 10 250 10 250 10400 10 400 10 400 24 400 24630 10 630 10 630 24 630 24
Functions with fuses (DIN)Max. load
in (kW)Motor starter DOLModule size in (E)
Motor starter ReverseModule size in (E)
Motor starter Star/DeltaModule size in (E)
at 400 Vac at 690 Vac at 400 Vac at 690 Vac at 400 Vac at 690 Vac11 5 515 10
18,5 522 530 537 10 10 10 10 1045 10 1255 12 24 1075 3090 24 30 24
132 36 30 36 30 24200 36220 36 36 36 36 36 30
Empty modules for motor control applications
Height in (E) 4 5 6 8 10 12 16 18 24 30 36Fixed x x x x x x
Currentin (A)
Feeder [3 pole]Module size in (E)
Feeder [4 pole]Module size in (E)
at 400 Vac at 690 Vac at 400 Vac at 690 Vac63 5 5 6 10
160 5 10 6 10400 10 10 12 12630 10 10 12 12
Functions with fuses (DIN)Max. load
in (kW)Motor starter DOLModule size in (E)
Motor starter ReverseModule size in (E)
Motor starter Star/DeltaModule size in (E)
at 400 Vac at 690 Vac at 400 Vac at 690 Vac at 400 Vac at 690 Vac11 5 515 8
18,5 522 530 837 8 8 8 8 845 8 1255 12 18 875 2490 18 24 18
132 24 18 30 24 18200 30220 36 18 36 30 36 30
Currentin (A)
Feeder (3 pole)Module size in (E)
Feeder (4 pole)Module size in (E)
at 400 Vac at 690 Vac at 400 Vac at 690 Vac160 2 2 4 4250 3 3 6 6400 6 6 12 12630 6 6 12 12
Functions with circuit breakersMax. load
in (kW)Motor starter DOLModule size in (E)
Motor starter ReverseModule size in (E)
Motor starter Star/DeltaModule size in (E)
at 400 Vac at 690 Vac at 400 Vac at 690 Vac at 400 Vac at 690 Vac11 10 1015 1030 4 10 4 10 437 555 10 18 2475 18 18 2490 24 30
110 30 36132 18 24160 24220 18 30 30250 24 36 36
Currentin (A)
Feeder (3 pole)Module size in (E)
Feeder (4 pole)Module size in (E)
at 400 Vac at 690 Vac at 400 Vac at 690 Vac63 4 8 8 8
160 5 8 8 8400 10 24 10 24630 18 24 18 24
Stan
dard
app
licat
ions
12
SEN Plus
13
SEN PlusD
imensionsD
imen
sion
s
Power center
DimensionsHeight: 2000/2200 mm Depth: 600/800/1200 mmWidth: 400/500/600/800/1000/1200 mm
Depth Current
600 mm 3200 A
800 mm 4000 A
1200 mm 6300 A
Motor control center
DimensionsHeight: 2000/2200 mm Depth: 600/800/1200 mmWidth: 800/1000/1200 mm
Depth Current
600 mm 3200 A
800 mm 4000 A
1200 mm 6300 A
• All widths available with 3 doors or one large door
• Available in combination withEntelliGuard Air Circuit Breaker
400 mm 1000 A 1 ACB
500 mm 2000 A 1 ACB
600 mm 2500 A 1 or 2 ACB
800 mm 3200 A 1 or 2 ACB
1000 mm 6300 A 1 ACB
1200 mm 6300 A 4-pole 1 ACB
• Cable compartment in different widths available
• Module sizes from 2 to 36 E 1E=25 mm– Fixed modules – Plug-in modules– Fully withdrawable modules
• Power ranges see pages 10 and 11
Drawer compartment
Cable compartment
Busbar compartment
600 mm
800 mm
1200 mm
2000
/220
0
600 mm
800 mm
1200 mm
2000
/220
0
600 mm
800 mm
1200 mm
2000
/220
0
600 mm
800 mm
1200 mm
2000
/220
0
400 800
1000 1000
600 mm
800 mm
1200 mm
2000
/220
0
600 mm
800 mm
1200 mm
2000
/220
0
1200 1200
680808Ref. E/5361/E/EX 8.0 Ed. 02/10
© Copyright GE Power Protection 2010
@
Power Protection (formerly GE Power Controls), a division of GE Industrial Solutions, is a fi rst class European supplier of low-voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company’s products comes from wholesalers, installers, panel-board builders, contractors, OEMsand utilities worldwide.
www.ge.com/ex/powerprotection www.ge.com/eu/powerprotection
GEPower Protection
4831
0
GE CONSUMER & INDUSTRIAL HUNGARYVáci út 77 H-1340 Budapest Hungary
Customer Service Tel. +361 447 6046 Fax +361 447 5060 E-mail: mea.export [email protected]: www.gepowershop.com
GE POWER CONTROLS Ltd Salthouse Road Brackmills NorthamptonNN4 7EXUnited Kingdom
Customer Service Tel. 0800 587 1251 Fax 0800 587 1239 E-mail: [email protected]
GE POWER PROTECTIONNieuwevaart 51B-9000 Gent - BelgiumTel. +32/9 265 21 11Fax +32/9 265 28 00E-mail: [email protected]
GE imagination at work