GE Molded Case Circuit Breakers
* TEYLine Circuit Breakers15-100 amperes
277 Vac, Single-Pole250Vd.c
480Y/277 Vac, Two- and Three-Pole60/7 5 °C Conductor Ratings
UL listed as HACR type
Bolt-On Mounting Base for TEY(For 1-, 2-, or 3-Pole)
Description
Accepts one three-pole or threesingle-pole breakers. Base assembliesstack together with no loss of one poleper inch spacing.
CatalogNumber
TEY3B
ListPrice, GO-1 35B
$31.50
The TEY is a one-inch wide per pole, compact, "bolt-on" circuitbreaker for use on grounded 480Y/277 Vac systems. The bolt-onmounting base, shown in the accessory table below, makes theTEY suitable for varied applications as a lug-lug breaker.
UL Listed Interrupting Ratings(rms symmetrical kilo-amperes)
System Voltage
Single-poleTwo-poleThree-pole
120 Vac
65
240 Vac
146565
277 Vac14
480Y/277 Vac
1414
125 Vdc
1010
250 Vdc
10
AmpereRating
152030405060708090
100
Single-Pole
CatalogNumber
TEY115®TEY120®TEY130TEY140TEY150TEY160TEY170TEY180TEY190TEY1100
ListPrice
GO-135B
$ 72.0072.0072.0072.0072.0072.00
142.00142.00142.00142.00
Two-Pole
CatalogNumber
TEY215TEY220TEY230TEY240TEY250TEY260TEY270TEY280TEY290TEY2100
UstPrice
GO-135B
$216.00216.00216.00216.00216.00216.00352.00352.00352.00352.00
Three-Pole
CatalogNumber
TEY315TEY320TEY330TEY340TEY350TEY360TEY370TEY380TEY390TEY3100
ListPrice
GO-135B
$316.00316.00316.00316.00316.00316.00424.00424.00424.00424.00
Internal Accessories For TEY(Two- and Three-Pole Breaker Only—Factory Installed Only)
Auxiliary Switch, Single-Pole(6A at 240 Vac. 1M at 1 25 Vdc, ViA at 250 Vdc,
"A" switch (normally open)"B" switch (normally closed)"AB" switch (both)
Shunt Trip1 20-277 Vac control voltage
Add suffix toBreaker
Catalog Number
ASIAAS1BASAB
ST12
ListPrice Adder,
GO-135B
$148.00148.00
' 288.00
358.00
Available Wire RangesCircuit Breaker (load lug)15, 20A
30-60A
70-1 OOA
Bolt-on Mounting Base,Cat. No. TEY3B (line lugs)
#14, #12Cu#12, #10 Al
#10-6Cu#8-4 Al
#4-1 Cu#2-1/0 Al
#14-1/0 Cu#12-1/0 Al
CD Single-pole, 15 and 20 amp breakers are also UL listed as switchingduty breakers, suitable for switching 120, 240, or 277 Volts ac.
Prices and data subject to change without notice 1999 Issue 4-17
GE Molded Case Circuit Breakers
K1200 Line• Thermal Magnetic Circuit Breakers• Magnetic Breakers• Molded-Case SwitchesThese breakers are available only with interchangeable trip units.Two frame sizes are available, the 800 ampere frame (300 to 800amperes) and the 1200 ampere frame (600 to 1200 amperes). Tripunits are not interchangeable between frames.
"Complete Circuit Breaker" price includes frame, trip, Cu/AI line,and load lugs. Units will be shipped unassembled unless specified"must be factory assembled." If line lugs are not required on thebreaker, eliminate "WL" from catalog number and subtract priceof line lugs.
To order the frame, trip, and lugs separately, select the requiredcomponents from table. Magnetic circuit breakers must beordered as components. A complete breaker consists of frame,trip and one line and one load lug per pole. Price of ordering"Complete Circuit Breaker" vs. frame, trip, and line and load lugsseparately is the same.
Molded-case switches can also be ordered as complete units(designated Type TKMA—Y) or as separate components. Theyare UL listed only as complete units. To indicate required lugs,see the table below.
x Unless otherwise noted, all circuit breakers are UL listed in FileE-11592. Molded-case switches are UL listed in File E-57546.R Frame—1000/1600/2000 Amp Molded-Case Circuit Breakers• Solid-state MicroVersaTrip Plus™ or MicroVersaTrip PM™
Trip Unit• Interchangeable trip unit via rating plugs• 65 and 100 kA ratings available• Standard and 100% rated versions• Uses standard Power Break* accessories• Stationary/manual onlyCurrent Limiting Circuit Breakers• 150, 225, 400 and 600 ampere frame sizes• UL listed interrupting ratings are 200 kA at 240 and 480 volts ac
maximum and 50 kA at 600 volts ac maximum• Thermal magnetic constructionCircuit Breakers with MicroVersaTrip' Trip Units• Solid-state construction with MicroVersaTrip RMS-9 digital rms
sensing microprocessor trip units.• Available in J and K frame construction with ampere ratings from
60-1200A.For ordering information see pages 4-36 through 4-41. UL listed,File E-11592. All breakers are UL listed in File E-11592.Tri-Break' Line• Integrally Fused Thermal Magnetic Circuit Breakers• Integrally Fused Magnetic Circuit Breakers• Integrally Fused Molded-Case Switches
Molded Case Circuit BreakersThese breakers are available in four types. Type TB1 (15-100amperes) catalog numbers include frame, trip, line and load lugs,and current limiters all factory assembled. Types TB4 (125 to 400amperes), TB6 (300 to 600 amperes) and TB8 (600 to 800 amperes)include frame, trip and limiters, factory assembled, but do notinclude line or load lugs. If line and load lugs are required, orderseparately. Unless otherwise noted, TB1, TB4, TB6, and TB8breaker components are UL listed in File E-42263. Fusedmolded-case switches are UL listed in File E-57546.Mag-Break9 Line• Magnetic only circuit breakers (motor circuit protectors)
These breakers are available only with noninterchangeableadjustable magnetic trip, in frame Types E, F, J, K, and Tri-Break.All breakers are shipped factory assembled, complete with Cu/AIline and load lugs.
All magnetic only circuit breakers and limiters are UL ComponentRecognized in Files E-11592 and E-66390, respectively, unlessotherwise noted.
AccessoriesOrder accessories from the appropriate table:
Thermal Magnetic Circuit Breakers, Magnetic Circuit Breakers, andMolded-Case Switches®—pages 4-48 to 4-65.MicroVersaTrip RMS-9 or 4-function Solid-State Circuit Breakers— .pages 4-48 to 4-65.
© Installation of accessories in molded-case switches requires dummytrip; see page 4-51 for information. Dummy trip not required forTri-Break or Q Line molded-case switches.
Spectra RMS™ Breakers—pages 4-47 to 4-65.Spectra RMS™ Breakers with MicroVersaTrip Plus™ Trip Units orMicroVersaTrip PM™ Trip Units—pages 4-32 to 4-35 and 4-47 to 4-65.
Molded-Case Circuit Breaker and SwitchTerminal Configuration CodeOrder standard Cu/AI lugs by using suffix codes presented. Order lugsseparately if special lugs are required. For optional lugs, see page 4-62.
Breaker/SwitchType
TQD/TJD
Molded CaseBreakers,ThermalMagneticMoldedCaseSwitchSpectra RMS™BreakersJ.K.MicroVersaTrip"BreakersMine Duty™BreakersMag- Break*Breakers
Suffix
BlankLoadLugsOnly
LoadLugsOnly
Line andLoadLugsNo
Lugs
NoLugs
NoLugs
Line andLoad Lugs
WL
Line andLoad Lugs
Line andLoad Lugs
-
XL
-
-
NoLugs
X2LineLugsOnly
LineLugsOnly
LineLugsOnly
LL
NoLugs
NoLugs
LoadLugsOnly
Order Lugs Separately
Order Lugs Separately
Order Lugs Separately
- - - —
For E 150 circuit breakers suffix XL is used to specify "no lugs".
Data subject to change without notice 1999 Issue 4-3
pi N II
GE Molded Case Circuit Breakerst. VERTICAL Molded Case Circuit Breakers
Quick Reference GuideRatings do not apply to molded-case switches.
TJJ, TJK, THJK TFJ, TFK, THFK
E150 (UL File E-11592; Fixed Thermal Magnetic Trip Unit; CSA LR 57114)
Jlte^
CircuitBreakerType
TEY®
TEB®
TED®
THED®
TEL®
AmpereRating
15-100
10-1009>
10-100
15-10010-150
15-30
15-100
15-1001 1 0 - 1 5 0
-15-150
No.Poles
12
3
1
2
3
1
2 '
3
1
2
3
3
MaximumVoltage Rating
ac277
120
277,347®480
600
277,347®
480
480,600
600
do125
250
125
250
—
125
250
500
125
250
-
UL Listed Interrupting Ratings—rms Symmetrical Amps (In Thousands)ac Voltage
12065
10
-
-
120/240
-
—
-
100
240
14
65
—
10
—
18
—
65
65
42
100
277
14
1 4
-
14
65
-
-
480
-
-
10
1 8
—
25
65
600
-
-
—
—
1 4
—
18
25
do Voltage1251 01 0—
5——
10
20®
-
-
250
—
1 0
—
5
—
—
10
10
—
20®
10
-
500®—
—
—
—
—
—
10
—
—
-
Dimensions(In.)
H
5'/4
65/ie
6^16
65/16
65/ie
W
1
2
3
1%
2%'
4Vfr
1%
23/4
41*
1%
41/a
4'/B
D
3'/18
3%
3%
3%
ytte
A
-
24'/64
Z"A>
2"/tn
27/16
B
-
2'%4
21%4
21s/64
2'%2
c
-
"/16
__
1 '/16
——
"/,6
11/16
E
-
s%2
23/32
2%2
2%2
Approx.Ship Wt./Std. Pack
26 lb/2424 lb/1 2
28 lb/8
26 lb/24
24lb/1228 lb/8
26 lb/24
24lb/12
28 lb/8
3Vz lb/1
"225 (UL File E-11592; TFJ, Fixed Thermal Magnetic Trip Unit; TFK, THFK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)
CircuitBreaker
Type
TFJ®
TFK®
THFK®
TFL®
AmpereRating
70-225
70-250
70-225
70-225
70-225
No.Poles
2
3
2
3
2
3
3
MaximumVoltage Rating
ac480
600
480
600
480
600
600
dc
250
500
250
—
250
—
-
UL Listed Interrupting Ratings —rms Symmetrical Amps (In Thousands)ac Voltage
120
-
120/240
100
240
25
25
65
100
277
-
480
22
22
25
65
600
—
1 8
_
18
—
1 8
25
dc Voltage125
-
2501 0
10®
10
—
20®
—
-
500®—
10
—
—
_
—
-
Dimensions(in.)
H
10'/8
101*
10'/B
101*
W
41*
4%
41*
'41*
D
3'Vie
31yi«
3^18
3«/16
A
3%
3%
37/6
3%
B
3'/B
3%
3%
3%
C
"/16
"/,e
"/16
11/16
E
1 3 /16 •
1*i6
1Vie
1*ie
Approx.Ship Wt./Std. Pack
10 lb/1
12 lb/110 lb/112 lb/110 lb/112 lb/1
-
J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)
TJK4
THJK4
250-600
250-600
2
3
2
3
2
3
2
3
600
600
250
500
250
500
250
—
250
-
42
65
30
35
2210
20
10
20®
40
—
40
-
—
' 20®
—
20
—
—
—
_
81/4
3'3/16
3%
315/16 3^16
3«/16
1% 1*6
16lb/117'/2lb/1
18 lb/120 lb/116 lb/1
17Vzlb/1
18 lb/120 lb/1
K1200 (UL File E-11592; Interchangeable Thermal Magnetic Trip Unit; CSA LR 40350)
TKM8
TKM12
THKM12
2
3
2
3
2
3
2
3
600250
500
250
—
42
65 35
.2210
20 <D
40®
—
—
22
—
—8'/4
5'/2
5/2
SQ/IB
5"/16
1%
1%
%
%
33 lb/1
39 lb/138 lb/1
41VMW133 lb/139 lb/138 lb/1
41 14 lb/1
UL listed with poles in seriesfor 500 Vdc ungroundedbattery applications.
© All UL listed as HACR type.® 10 amp not UL listed.
® UL listed/CSA Certified for10kA @ 347 Vac (TED) and18kA@ 347V (THED). Alsorated 10kA @ 480V but notUL listed.
© UL listed at 10,000 amps.® Discontinued© Also 10,000 amps at 500 Volts
dc. Not UL listed.
500 Vdc on TJJ only.
(continued on page 4-8)
Data subject to change without notice 1999 Issue 4-7