ge circuit breakers and disconnects thermal-magnetic ... · a complete circuit breaker consists of...

2
GE Circuit Breakers and Disconnects Note: All UL listed as HACR type except 10 amp Types TEB, TED, THED— Noninterchangeable Trip Thermal-Magnetic Molded-Case Circuit Breakers bO°C/75°C Conduttoi 10-150 Amperes Rating! hi ough lOOAmpeies, 120-600 Volts AC 75°C Above 100 Amperes 125, 250 Volts DC Single-Pole—Includes Cu/AI load lugs only. If line lugs are required, add suffix "WL" to Catalog Number. One-Pole Two-Pole Three-Pole Ampere Rating 10 15 20 25 30 35 40 45 50 60 70 80 90 100 100NA Type TEB 120 Vac 125 Vdc Catalog Number TEB111010® TEB111015© TEB111020® TEB111025 TEBI 11030 TEB1 11035 TEB111040 TEB111045 TEB111050 TEB111060 TEB1I1070 TEB1 11080 TEB111090 TEB111100 TEB111Y100®® List Price, GO-135B $ 78.50 78.50 78.50 78.50 78.50 78.50 78.50 78.50 78.50 78.50 13400 134.00 134.00 134.00 65.50 Type TED 277 Vac 125 Vdc Catalog Number TED1 13010® TED1 13015® TED1 13020® TED1 13025 TED1 13030 TED1 13035 TED1 13040 TED1 13045 TED1 13050 TED1 13060 TED1 13070 TED1 13080 TEDI 1 3090 TED113100 TED113Y100®® List Price, GO-135B $ 82.50 82.50 8250 8250 82.50 82.50 82.50 82.50 82.50 82.50 159.00 159.00 159.00 159.00 82.50 347 Volts AC® Catalog Number TED1 14015 TED1 14020 TED1 14025 TED1 14030 _ _ _ List Price, GO-1358 $152.00 152.00 15200 152.00 _ _ - Type THED 347 Volts AC Catalog Number THED114015® THFD1 14020® THED1 14025 THED1 14030 _ - List Price, GO-135B $416.00 416.00 416.00 416.00 _ _ _ - Two-Pole—Includes Cu/AI Line and Load Lugs. Ampere Rating 10 15 20 25 30 35 40 45 50 60 70 80 90 100 100NA 150NA Type TEB 240 Vac, 250 Vdc Catalog Number TEB122010WL® TEB122015WL TEB1220?OWL TEB122025WL TEB1P2030WL rEB122035WL TEB122040WL TEB122045WL TEBI22050WL TEB122060WL TEB122070WL TtB122080WL TEB122090WL TEB122100WL TEB122Y100® List Price, GO-135B $159.00 159.00 159.00 159.00 159.00 159.00 159.00 159.00 159.00 159.00 261 00 261 00 261.00 261.00 15900 Type TED 480 Vac 250 Vdc Catalog Number TED124010WL® TED 1 2401 5WL TED124020WL TED124025WL TED124030WL TED124035WL TED124040WL TED124045WL TED124050WL TED124060WL TED124070WL TED124080WL TED124090WL TED124100WL TED124Y100® TED124Y1500® List Price, GO-135B $290.00 290.00 290.00 290.00 290.00 290.00 290.00 290.00 290.00 290.00 377.00 377.00 377.00 377.00 26300 70800 Type THED Hi Break ® 480 Vac 250 Vdc Catalog Number THED124015WL THED124020WL THED124025WL THED124030WL THED124035WL THED124040WL THED124045WL THED124050WL THED124060WL THED124070WL THED124080WL FHED124090WL THFD124100WL - List Price, GO-135B $560.00 560.00 560.00 560.00 560.00 560.00 560.00 560.00 560.00 65300 65300 653.00 653.00 - Three-Pole—Includes Cu/AI Line and Load Lugs. Ampere Rating 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150 100NA 150NA Type TEB 240 Volts AC Catalog Number TEB1 3201 OWL® TEB132015WL TEB132020WL TEB132025WL TEB132030WL TEB132035WL TEB132040WL TEB132045WL TEB132050WL TEB132060WL TEB132070VVL TEB132080WL TEB132090WL TEB132100WL TEB132Y100® List Price, GO-135B $240.00 24000 24000 240.00 240.00 240.00 240.00 24000 240.00 240.00 339.00 339.00 339.00 339.00 240.00 Type TED 480 Volts AC Catalog Number TED134010WL® TED134015WL TED134020WL TED134025WL TED134030WL TED134035WL TED134040WL TED134045WL TED134050WL TED134060WL TED134070WL TEDI34080WL TED134090WL TED134100WL TED1 3411 OWL TED134125WL TED134150WL TED134YT100® TED134YT150® List Price, GO-135B $ 377.00 377.00 377.00 377.00 377.00 377.00 377.00 377.00 377.00 377.00 445.00 445.00 445.00 445.00 1198.00 1198.00 1198.00 377.00 967.00 Type TED ] Type THED Hi Break 600 Volts AC Catalog Number TED136015WL TED136020WL TED136025WL TED136030WL TED136035WL TED136040WL TED136045WL TED136050WL TED136060WL TED136070WL TED136080WL TED136090WL TED136100WL TED136110WL TED136125WL TED136150WL TED136YT100® TED136YT150® List Price, GO-135B $ 439.00 439.00 439.00 439.00 439.00 439.00 439.00 439.00 439.00 534.00 534.00 53400 53400 1188.00 1198.00 1198.00 445.00 967.00 480 Volts AC Catalog Number - - THED134110WL THED134125WL THED134150WL 600 Volts AC Catalog Number THED136015WL THED136020WL THED136025WL THED136030WL THED136035WL THED136040WL THED136045WL THED136050WL THED136060WL THED136070WL THED136080WL THED136090WL THED 1361 OOWL THED136110WL THED136125WL THED136150WL - List Price, GO-135B $ 655.00 655.00 655.00 655.00 655.00 655.00 655.00 655.00 65500 742.00 742.00 742.00 742.00 168300 1683.00 1683.00 ffi Single-pole, 15- and 20-amp breakers are also UL listed as switching-duty breakers, suitable for switching 120 volts ac (TEB), 277 volts ac (TED, THED) fluorescent lighting loads Suitable for 10kAIC at 480 Vac, but not labelled or UL listed Molded-case switch Internal accessory installation requires factory installed dummy trip specify on order Accessories not available for one-pole TEB, TED See page 16-23 ® Two-pole breaker is furnished in three pole case © Molded-case switch includes line and load lugs ® Includes factory installed dummy trip Accessories: See pages 16-19 to 16-32 Prices and data subject to change without notice 1999 Issue 16-7

Upload: others

Post on 17-Aug-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GE Circuit Breakers and Disconnects Thermal-Magnetic ... · A complete circuit breaker consists of a UL listed circuit breaker frame and a rating plug (UL listed interchangeable trip

GE Circuit Breakers and Disconnects

Note: All UL listed as HACRtype except 10 amp

Types TEB, TED,THED—Noninterchangeable Trip

Thermal-Magnetic Molded-Case Circuit BreakersbO°C/75°C Conduttoi 10-150 Amperes

Rating! hi ough lOOAmpeies, 120-600 Volts AC75°C Above 100 Amperes 125, 250 Volts DC

Single-Pole—Includes Cu/AI load lugs only. If linelugs are required, add suffix "WL" to Catalog Number.

One-Pole Two-Pole Three-Pole

AmpereRating

1 01 52025303540455060

708090

100

100NA

Type TEB

120 Vac125 Vdc

Catalog Number

T E B 1 1 1 0 1 0 ®T E B 1 1 1 0 1 5 ©TEB111020®TEB111025TEBI 1 1 0 3 0TEB1 11035T E B 1 1 1 0 4 0TEB111045TEB111050TEB111060

TEB1I1070TEB1 11080TEB111090T E B 1 1 1 1 0 0

TEB111Y100®®

ListPrice,

GO-135B

$ 78.5078.5078.5078.5078.5078.5078.5078.5078.5078.50

13400134.00134.00134.00

65.50

Type TED

277 Vac125 Vdc

Catalog Number

TED1 1 3 0 1 0 ®TED1 13015®TED1 13020®TED1 13025TED1 13030TED1 13035TED1 13040TED1 13045TED1 13050TED1 13060

TED1 13070TED1 13080TEDI 1 3090TED113100

TED113Y100®®

ListPrice,

GO-135B

$ 82.5082.508250825082.5082.5082.5082.5082.5082.50

159.00159.00159.00159.00

82.50

347 Volts AC®Catalog Number

TED1 14015TED1 14020TED1 14025TED1 14030

_————__——

ListPrice,

GO-1358

$152.00152.0015200152.00

_————_———

-

Type THED

347 Volts ACCatalog Number

THED114015®THFD1 14020®THED1 14025THED1 14030

—————_———

-

ListPrice,

GO-135B

$416.00416.00416.00416.00

_————__——

-

Two-Pole—Includes Cu/AI Line and Load Lugs.

AmpereRating

101 52025303540455060

708090

100

100NA150NA

Type TEB

240 Vac, 250 VdcCatalog Number

TEB122010WL®TEB122015WLTEB1220?OWLTEB122025WLTEB1P2030WLrEB122035WLTEB122040WLTEB122045WLTEBI22050WLTEB122060WL

TEB122070WLTtB122080WLTEB122090WLTEB122100WL

TEB122Y100®

ListPrice,

GO-135B

$159.00159.00159.00159.00159.00159.00159.00159.00159.00159.00

261 00261 00261.00261.00

15900

Type TED

480 Vac 250 VdcCatalog Number

TED124010WL®TED 1 2401 5WLTED124020WLTED124025WLTED124030WLTED124035WLTED124040WLTED124045WLTED124050WLTED124060WL

TED124070WLTED124080WLTED124090WLTED124100WL

TED124Y100®TED124Y1500®

ListPrice,

GO-135B

$290.00290.00290.00290.00290.00290.00290.00290.00290.00290.00

377.00377.00377.00377.00

2630070800

Type THED Hi Break ®

480 Vac 250 VdcCatalog Number

THED124015WLTHED124020WLTHED124025WLTHED124030WLTHED124035WLTHED124040WLTHED124045WLTHED124050WLTHED124060WL

THED124070WLTHED124080WLFHED124090WLTHFD124100WL

-

ListPrice,

GO-135B

$560.00560.00560.00560.00560.00560.00560.00560.00560.00

6530065300653.00653.00

-

Three-Pole—Includes Cu/AI Line and Load Lugs.

AmpereRating

101 52025303540455060

708090

100

1 1 0125150

100NA150NA

Type TEB

240 Volts ACCatalog Number

TEB1 3201 OWL®TEB132015WLTEB132020WLTEB132025WLTEB132030WLTEB132035WLTEB132040WLTEB132045WLTEB132050WLTEB132060WL

TEB132070VVLTEB132080WLTEB132090WLTEB132100WL

TEB132Y100®

ListPrice,

GO-135B

$240.002400024000240.00240.00240.00240.0024000240.00240.00

339.00339.00339.00339.00

240.00

Type TED

480 Volts ACCatalog Number

TED134010WL®TED134015WLTED134020WLTED134025WLTED134030WLTED134035WLTED134040WLTED134045WLTED134050WLTED134060WL

TED134070WLTEDI34080WLTED134090WLTED134100WL

TED1 3 4 1 1 OWLTED134125WLTED134150WL

TED134YT100®TED134YT150®

ListPrice,

GO-135B

$ 377.00377.00377.00377.00377.00377.00377.00377.00377.00377.00

445.00445.00445.00445.00

1198.001198.001198.00

377.00967.00

Type TED ] Type THED Hi Break

600 Volts ACCatalog Number

TED136015WLTED136020WLTED136025WLTED136030WLTED136035WLTED136040WLTED136045WLTED136050WLTED136060WL

TED136070WLTED136080WLTED136090WLTED136100WL

TED136110WLTED136125WLTED136150WL

TED136YT100®TED136YT150®

ListPrice,

GO-135B

$ 439.00439.00439.00439.00439.00439.00439.00439.00439.00

534.00534.005340053400

1188.001198.001198.00

445.00967.00

480 Volts ACCatalog Number

-

-

THED134110WLTHED134125WLTHED134150WL

600 Volts ACCatalog Number

THED136015WLTHED136020WLTHED136025WLTHED136030WLTHED136035WLTHED136040WLTHED136045WLTHED136050WLTHED136060WL

THED136070WLTHED136080WLTHED136090WLTHED 1 361 OOWL

THED136110WLTHED136125WLTHED136150WL

-

ListPrice,

GO-135B

$ 655.00655.00655.00655.00655.00655.00655.00655.0065500

742.00742.00742.00742.00

1683001683.001683.00

ffi Single-pole, 15- and 20-ampbreakers are also UL listed asswitching-duty breakers,suitable for switching 120 voltsac (TEB), 277 volts ac (TED,THED) fluorescent lightingloads

Suitable for 10kAIC at 480 Vac,but not labelled or UL listedMolded-case switch Internalaccessory installation requiresfactory installed dummy tripspecify on order Accessoriesnot available for one-pole TEB,TED See page 16-23

® Two-pole breaker is furnishedin three pole case

© Molded-case switch includesline and load lugs

® Includes factory installeddummy trip

Accessories:See pages 16-19 to 16-32

Prices and data subject to change without notice 1999 Issue 16-7

Page 2: GE Circuit Breakers and Disconnects Thermal-Magnetic ... · A complete circuit breaker consists of a UL listed circuit breaker frame and a rating plug (UL listed interchangeable trip

Gf Circuit Breakers and Disconnects

Section 16

Spectra RMS™ Molded Case Circuit BreakersFeaturesSE150, SF250, SG600 and SK1200 circuit breaker frames have adigital solid state, rms sensing trip system with field installable,front-mounted rating plugs to establish or change the breakerampere rating Adjustable instantaneous with tracking short-timeis standard on all frames including SE150

A complete circuit breaker consists of a UL listed circuit breakerframe and a rating plug (UL listed interchangeable trip unit)Terminal lugs for cable connection are available if required

• All frames use the same UL listed field-installable internalaccessories (auxiliary switch shunt trip undervoltage release,and bell alarm)

• All frame sizes have maximum UL listed interrupting ratings of200 kA @ 240 volts ac and 100 kA @ 480 volts ac with 600 voltsac ratings to 65 kA depending on frame size UL listed currentlimiting versions are provided through the SG600 frame for the65 kA @ 480 volts ac and the 100 kA @ 480 volts ac modelswith no increase in physical frame size

• Spectra RMS Mag-Break* instantaneous-only motor circuitprotectors also use the same digital, solid-state trip unit andrating plugs as the circuit breakers The interchangeable ratingplug establishes the instantaneous pickup range (with trackingshort-time) but does not change the frame ampere rating

• Spectra RMS molded case switches have a fixed, high-setinstantaneous trip (without tracking short-time function) andhave short circuit withstand ratings equal to their equivalentbreaker frame size interrupting rating in most cases

• Spectra RMS breakers are ambient insensitive Trip times will notvary over the range 10-50°C breaker ambient Refer to GET-7002for further application information

• Spectra RMS breakers contain no parts that would supportfungus growth and are therefore inherently fungusproof

Other MCCB Features• Broad product line to meet virtually any application need• Reduced downtime A tripped breaker is easily spotted and can

be immediately reset after the fault has been corrected• Eliminates single phasing A common trip bar disconnects all

poles simultaneously on both overloads and short circuits• Offers application flexibility through the use of a wide variety of

accessory devices and special attachments• Repetitive operation—no fuses to replace• Breakers can be repetitively tested Fuses must be destroyed to

confirm calibration accuracy

For more information on GE Disconnects and Circuit Breakerssee Publication Index Section 18

Fusible SwitchesNonfusible Switches

16-216-2

Type FD1 Fusible Disconnect Switches 16-3 16-4DILOS Nonfusible Disconnect Switches 16-5,16-6Molded Case Circuit Breakers 16-7 to 16-18Accessories and Modifications 16-19 to 16-32V-Line™ Miniature Circuit Breakers 16-33 to 16-36

1999 Issue 16-1