MS439466B GC FUJI ORTHO BAND LC PASTE PAK AUTOMIX – PASTE B Page 1 of 2 MATERIAL SAFETY DATA SHEET
SECTION 1 - SOURCE/IDENTITY/USE INFORMATION DISTRIBUTOR GC AMERICA INC. 3737 West 127th St. Alsip, Illinois, 60803 Telephone: 708-597-0900 Hours: Mon.- Fri. 8:00 am. - 5:00 pm. C.S.T. Transportation Emergency No. 800-424-9300 COMMON NAME: GC FUJI ORTHO BAND LC PASTE PAK AUTOMIX – PASTE B CHEMICAL NAME: N.A. PRODUCT USE: Light-cured glass ionomer for bonding of orthodontic appliances. The following information is provided with regard to the toxicity and hazards the pure components present in this product. SECTION 2 - HAZARDOUS INGREDIENTS/IDENTITY INFORMATION
COMPONENT C.A.S. EXPOSURE LIMITS LD50/LC50 %
Polyacrylic acid TWA=10ppm (ACGIH)
LD50=2500mg/kg (oral rat)
30-35
Distilled water N.E. N.E. 30-35 Silicon dioxide (fumed amorphous)
7631-86-9 N.E. N.E. 23
Polybasic carboxylic acid N.E. N.E. 5-10 Initiator N.E. N.E. 1-5
SECTION 3 - PHYSICAL/CHEMICAL PROPERTIES
BOILING POINT: N.E. SPECIFIC GRAVITY: N.E. VAPOR PRESSURE: N.E. MELTING POINT: N.E. VAPOR DENSITY: 1.5g/mL EVAPORATION RATE : N.E. SOLUBILITY IN WATER: Partially soluble in water ODOR THRESHOLD: N.E. COEFFICIENT OF OIL/WATER DISTRIBUTION: N.E. APPEARANCE AND ODOR: Odorless paste SECTION 4 - FIRE AND EXPLOSION DATA FLASH POINT: N.E. FLAMMABLE LIMITS: N.E. EXTINGUISHING MEDIA: Alcohol foam, dry chemical SPECIAL FIRE FIGHTING PROCEDURES: N.E. UNUSUAL FIRE AND EXPLOSION HAZARDS: N.E. HAZARDOUS COMBUSTION PRODUCTS: N.E. SECTION 5 - REACTIVITY DATA STABILITY: Stable Unstable POLYMERIZATION: Will Not Occur Will Occur CONDITIONS TO AVOID: Avoid high temperatures. INCOMPATIBILITY (Materials to Avoid): None known HAZARDOUS DECOMPOSITION OR BY-PRODUCTS: No decomposition if used or stored according to specifications. SECTION 6 - HEALTH HAZARD DATA and FIRST AID INFORMATION
YES NO NE NA NTP IARC OSHA OTHER MUTAGENIC AFFECTS X TERATOGENIC AFFECTS X REPRODUCTIVE TOXIN X CARCINOGENICITY X SENSITIZER X
12 March 201226 May 2009
MS439466A GC FUJI ORTHO BAND LC PASTE PAK AUTOMIX – PASTE A Page 1 of 2 MATERIAL SAFETY DATA SHEET
SECTION 1 - SOURCE/IDENTITY/USE INFORMATION DISTRIBUTOR GC AMERICA INC. 3737 West 127th St. Alsip, Illinois, 60803 Telephone: 708-597-0900 Hours: Mon.- Fri. 8:00 am. - 5:00 pm. C.S.T. Transportation Emergency No. 800-424-9300 COMMON NAME: GC FUJI ORTHO BAND LC PASTE PAK AUTOMIX – PASTE A CHEMICAL NAME: N.A. PRODUCT USE: Light-cured glass ionomer for bonding of orthodontic appliances. The following information is provided with regard to the toxicity and hazards the pure components present in this product. SECTION 2 - HAZARDOUS INGREDIENTS/IDENTITY INFORMATION
COMPONENT C.A.S. EXPOSURE LIMITS LD50/LC50 %
Fluoro-alumino-silicate glass (amorphous)
TLV=10mg/m3
PEL=15mg/m3 (ACGIH)
N.E. 60-65
Dimethacrylate N.E. N.E. 25-30 Silicon dioxide 7631-86-9 N.E. N.E. 7 Urethanedimethacrylate N.E. N.E. 1-5
SECTION 3 - PHYSICAL/CHEMICAL PROPERTIES
BOILING POINT: N.E. SPECIFIC GRAVITY: N.E. VAPOR PRESSURE: N.E. MELTING POINT: N.E. VAPOR DENSITY: 2.0g/mL EVAPORATION RATE : N.E. SOLUBILITY IN WATER: Insoluble ODOR THRESHOLD: N.E. COEFFICIENT OF OIL/WATER DISTRIBUTION: N.E. APPEARANCE AND ODOR: Odorless paste SECTION 4 - FIRE AND EXPLOSION DATA FLASH POINT: 107°C FLAMMABLE LIMITS: N.E. EXTINGUISHING MEDIA: Use extinguishing media appropriate to the surrounding area. SPECIAL FIRE FIGHTING PROCEDURES: N.E. UNUSUAL FIRE AND EXPLOSION HAZARDS: N.E. HAZARDOUS COMBUSTION PRODUCTS: Carbon dioxide, carbon monoxide SECTION 5 - REACTIVITY DATA STABILITY: Stable Unstable POLYMERIZATION: Will Not Occur Will Occur CONDITIONS TO AVOID: Avoid high temperatures and humidity. INCOMPATIBILITY (Materials to Avoid): N.E. HAZARDOUS DECOMPOSITION OR BY-PRODUCTS: No decomposition if used or stored according to specifications. . SECTION 6 - HEALTH HAZARD DATA and FIRST AID INFORMATION
YES NO NE NA NTP IARC OSHA OTHER MUTAGENIC AFFECTS X TERATOGENIC AFFECTS X REPRODUCTIVE TOXIN X CARCINOGENICITY X SENSITIZER X
30 June 2008