gas sampling results, 1st quarter 2003, w/tl to d basinger ... · work order summary client: phone:...
TRANSCRIPT
"Gardner, Tom"<[email protected]>
07/01/2003 07:27 AM
SFUND RECORDS CTR
2066401
To: David Basinger/R9/USEPA/US@EPA, SteveWall/R9/USEPA/US@EPA, "Sandra Doty (E-mail)"<[email protected]>
cc: "Gaddy, Alan" <[email protected]>Subject: Landfill Gas Analysis
«0301202_d.pdf» «0301202COC.pdf» «lq2003h2s .pdf»«lQ20031fganalysis .pdf » «!Q2003sunlfgCOC.pdf »David, attached are electronic copies of the analytical data from the firstquarter of 2003. If you still want copies of the 4th quarter 2002, let meknow. I do not have electronic copies of the 4th quarter 2 0 0 2 . I will faxto you the last 5 well reading logs. If you have any other requests, pleaselet me know. Thanks. Tomg.
0301202_d.pdf 0301202COC.pdf 1q2003h2s.pdf 1Q2003lfganalysis.pdf 1Q2003sunlfgCOC.pdf
AIR TOXICS LTD.AN ENVIRONMENTAL ANALYTICAL LABORATORY
Air Toxics Ltd. Introduces the Electronic Report
Thank you for choosing Air Toxics Ltd. To better serve our customers, we are providing your report by e-mail.This document is provided in Portable Document Format which can be viewed with Acrobat Reader byAdobe.
This electronic report includes the following:• Work order Summary;• Laboratory Narrative;• Results; and• Chain of Custody (copy).
180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA - 95630
(916) 985-1000 .FAX (916) 985-1020Hours 8:00 A.M to 6:00 P.M. Pacific
E-mail to:[email protected]
@ AIR TOXICS LTD.AN ENVIRONMENTAL ANALYTICAL LABORATORY
WORK ORDER #: 0301202
Work Order Summary
CLIENT:
PHONE:
FAX:
DATE RECEIVED:DATE COMPLETED:
Mr. Rob TidwellEnvironmental Technologies of Nevada,Inc.770 East Sahara AvenueLas Vegas, NV 89104
702-734-5400
702-735-4523
1/8/03
1/8/03
BILL TO:
P.0.#
PROJECT #
CONTACT:
Mr. Rob TidwellEnvironmental Technologies of Nevada,Inc.770 East Sahara AvenueLas Vegas, NV 89104
10199007.01 Task 21 Sunrise Mtn Landfill
Karen Burden
FRACTION #01A02A03A
NAMEFlare R2Lab BlankLCS
TESTModified ASTMD-5504Modified ASTMD-5504Modified ASTMD-5504
RECEIPTVACJPRES.Tedlar Bag
NANA
CERTIFIED BY: DATE: 01/08/03
Laboratory Director
Certfication numbers: AR DEQ, CA NELAP - 02110CA, LA NELAP/LELAP- AI 30763, NJ NELAP - CA004NY NELAP - 11291, UT NELAP - 9166389892
Name of Accrediting Agency: NELAP/Florida Department of Health, Scope of Application: Clean Air Act,Accreditation number: E87680, Effective date: 07/01/02, Expiration date: 06/30/03
Air Toxics Ltd. certifies that the test results contained in this report meet all requirements of the NELAC standards
This report shall not be reproduced, except in full, without the written approval of Air Toxics Ltd.
180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA - 95630(916) 985-1000 . (800) 985-5955 . FAX (916) 985-1020
Pase 1 of 5
LABORATORY NARRATIVEModified ASTM D-5504
Environmental Technologies of Nevada, Inc.Workorder# 0301202
One 1 Liter Tedlar Bag sample was received on January 08, 2003. The laboratory performed the analysis ofsulfur compounds via Modified ASTM D-5504 using GC/SCD. The method involves direct injection of the airsample into the GC via a fixed 1.0 mL sampling loop. See the data sheets for the reporting limits for eachcompound.
Receiving Notes
There were no receiving discrepancies.
Analytical Notes
There were no analytical discrepancies.
Definition of Data Qualifying Flags
Seven qualifiers may have been used on the data analysis sheets and indicate as follows:B - Compound present in laboratory blank greater than reporting limit.J - Estimated value.E - Exceeds instrument calibration range.S - Saturated peak.Q - Exceeds quality control limits.U - Compound analyzed for but not detected above the detection limit.M - Reported value may be biased due to apparent matrix interferences.File extensions may have been used on the data analysis sheets and indicatesas follows:a-File was requantifiedb-File was quantified by a second column and detectorrl-File was requantified for the purpose of reissue
Page 2 of 5
AIR TOXICS LTD.SAMPLE NAME: Flare R2
ID#: 0301202-01A
SULFUR GASES BY MODIFIED ASTM D-5504 GC/SCD
File Name:Oil. Factor.
Compound
b010809„ t 10000 •J * gfk
Rpt. Limit(ppbv)
-'«.» Datg of Collection: 1/7/03Date of Analysis: 1/8/03
Amount(ppbv)
Hydrogen Sulfide 40000 6300000
Container Type: 1 Liter Tedlar Bag
Page 3 of 5
AIR TOXICS LTD.SAMPLE NAME: Lab Blank
ID#: 0301202-02ASULFUR GASES BY MODIFIED ASTM D-5504 GC/SCD
FIlaName:Ml. Factor
Compound
Hydrogen Sulfide
b0108041.00
Rpt. Limit(ppbv)
4.0
Date of Collection: NADate of Analysis: 1/8/03
Amount
Not Detected
Container Type: NA - Not Applicable
Page 4 of 5
AIR TOXICS LTD.SAMPLE NAME: LCS
ID#: 0301202-03ASULFUR GASES BY MODIFIED ASTM D-5504 GC/SCD
File Name:Oil. Factor.
Compound
«&,. 1-°° V, "/Nf^IxT »Rpt. Limit
(ppbv)
^ '^ Date of Collection: NA^ffxffKt Date of Analysis: 1/8/03
%Recovery
Hydrogen Sulfide 4.0 79
Container Type: NA - Not Applicable
Page 5 of 5
AIR TOXICS LTD.AN ENVIRONMENTAL ANALYTICAL LABORATORY
Air Toxics Ltd. Introduces the Electronic Report
Thank you for choosing Air Toxics Ltd. To better serve our customers, we are providing your report bye-mail. This document is provided in Portable Document Format which can be viewed with Acrobat Readerby Adobe.
This electronic report includes the following:• Work order Summary;• Laboratory Narrative;• Results; and• Chain of Custody (copy).
180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA - 95630
(916) 985-1000 .FAX (916) 985-1020Hours 8:00 A.M to 6:00 P.M. Pacific
E-mail to:[email protected]
AIR TOXICS LTD.AN ENVIRONMENTAL ANALYTICAL LABORATORY
WORK ORDER #: 0303267A
Work Order Summary
CLIENT:
PHONE:
FAX:
DATE RECEIVED:DATE COMPLETED:
Mr. Ty SalazarWestmark Environmental Services Inc.3642 North Rancho Dr.Suite 102Las Vegas, NV 89130
702-839-2960
702-839-2962
03/14/03
03/21/03
BELL TO:
P.O.*
PROJECT #
CONTACT:
Mr. Tom GardnerEnvironmental Technologies of Nevada,Inc.770 East Sahara AvenueLas Vegas, NV 89104
Sunrise Gas Samples
Kelly Buettner
FRACTION #01A02A03A04A
NAMEFlare Main-2SUNGW02Lab BlankLCS
TESTModified ASTM D-5504Modified ASTM D-5504Modified ASTM D-5504Modified ASTM D-5504
RECEIPTVAC./PRES.Tedlar BagTedlar Bag
NANA
CERTIFIED BY: DATE: 03/21/03
Laboratory Director
Certfication numbers: AR DEQ, CA NELAP - 0211 OCA, LA NELAP/LELAP- AI 30763, NJ NELAP - CA004NY NELAP - 11291, UT NELAP - 9166389892
Name of Accrediting Agency: NELAP/Florida Department of Health, Scope of Application: Clean Air Act,Accreditation number: E87680, Effective date: 07/01/02, Expiration date: 06/30/03
Air Toxics Ltd. certifies that the test results contained in this report meet all requirements of the NELAC standards
This report shall not be reproduced, except in full, without the written approval of Air Toxics Ltd.
180 BLUE RAVINE ROAD. SUITE B FOLSOM, CA - 95630(916) 985-1000 . (800) 985-5955 . FAX (916) 985-1020
Page 1 of6
LABORATORY NARRATIVEModified ASTM D-5504
Environmental Technologies of Nevada, Inc.Workorder# 0303267A
Two 1 Liter Tedlar Bag samples were received on March 14, 2003. The laboratory performed the analysisof sulfur compounds via Modified ASTM D-5504 using GC/SCD. The method involves direct injection olthe air sample into the GC via a fixed 1.0 mL sampling loop. See the data sheets for the reporting limits foreach compound.
RequirementDetection
Standards
Initial Calibration
Dilution
ASTMD-5504Less than 5 pgS/sensitivity
Permeation tubeCompressed cylindergas
External StandardSingle point at leastonce per day; The RFof each compoundshould be within 1 0 %of RF for DimethylSulfide.
Via split injection
ATL Modifications4 ppbv
Standards may also be formulated from liquid stock andblended in a Tedlar bag
External Standard Multi points (3compounds </= 30%; %RSD </=The low point of the curve is theLimit.
- 5) Average % RSD for all30 % for Hydrogen Sulfide.same as the Reporting
Bag or syringe dilution with N2
Receiving Notes
Samples Flare Main-2 and SUNGW02 were received past the recommended hold time of 24 hours. Thediscrepancy was noted in the Login email and the analysis proceeded.
Analytical Notes
There were no analytical discrepancies.
Definition of Data Qualifying Flags
Seven qualifiers may have been used on the data analysis sheets and indicate as follows:B - Compound present in laboratory blank greater than reporting limitJ - Estimated value.E - Exceeds instrument calibration range.S - Saturated peak.Q - Exceeds quality control limits.U - Compound analyzed for but not detected above the detection limitM - Reported value maybe biased due to apparent matrix interferences.File extensions may have been used on the data analysis sheets and indicatesas follows:a-File was requantifiedb-File was quantified by a second column and detectorrl-File was requantified for the purpose of reissue
Page 2 of 6
AIR TOXICS LTD.SAMPLE NAME: Flare Main-2
ID#: 0303267A-01A
SULFUR GASES BY MODIFIED ASTM D-5504 GC/SCD
File Name:DH. Factor:
Compound
~"C /. ' ' 2*5600 T~" " A ~-~* r t<* " *"£
Rpt. Limit(ppbv)
Date of Collection: 3/12/03Date of Analysis: 3/14/03
Amount(ppbv)
Hydrogen Sulfide 100000 12000000
Container Type: 1 Liter Tedlar Bag
Page 3 of 6
AIR TOXICS LTD.SAMPLE NAME: SUNGW02
ID#: 0303267A-02A
SULFUR GASES BY MODIFIED ASTM D-5504 GC/SCD
Fit* Name:Oil. Factor:
Compound
b03140650.0
Rpt. Limit(PPbv)
Date of Collection: 3/12/03Date of Analysis: 3/14/03
Amount(ppbv)
Hydrogen Sulfide 200 32000
Container Type: 1 Liter Tedlar Bag
Page 4 of 6
AIR TOXICS LTD.SAMPLE NAME: Lab Blank
ID#: 0303267A-03A
SULFUR GASES BY MODIFIED ASTM D-5504 GC/SCD
File Name:Oil. Factor:
Compound
b031403
1.00 * ISL >
Rpt. Limit<PPbv)
, Date of Collection: NADate of Analysis: 3/14/03
Amount(ppbv)
Hydrogen Sulfide 4.0 Not Detected
Container Type: NA - Not Applicable
Page 5 of 6
AIR TOXICS LTD.SAMPLE NAME: LCS
ID#: 0303267A-04A
SULFUR GASES BY MODIFIED ASTM D-5504 GC/SCD
Flla Name:Oil. Factor:
Compound
b0314021.00
Rpt. Limit(ppbv)
Date of Collection: NADate of Analysis: 3/14/03
%Recovery
Hydrogen Sulfide 4.0 116
Container Type: NA - Not Applicable
Page 6 of 6
AIR TOXICS LTD.AN ENVIRONMENTAL ANALYTICAL LABORATORY
Air Toxics Ltd. Introduces the Electronic Report
Thank you for choosing Air Toxics Ltd. To better serve our customers, we are providing your report by e-mail.This document is provided in Portable Document Format which can be viewed with Acrobat Reader byAdobe.
This electronic report includes the following:• Work order Summary;• Laboratory Narrative;• Results; and• Chain of Custody (copy).
180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA - 95630
(916) 985-1000 .FAX (916) 985-1020Hours 8:00 A.M to 6:00 P.M. Pacific
E-mail to:[email protected]
AIR TOXICS LTD.AN ENVIRONMENTAL ANALYTICAL LABORATORY
WORK ORDER #: 0303267BR1
Work Order Summary
CLIENT:
PHONE:
FAX:
DATE RECEIVED:
DATE COMPLETED:
DATE REISSUED:
FRACTION #01A02A03A04A
Mr. Ty SalazarWestmark Environmental Services Inc.3642 North Rancho Dr.Suite 102Las Vegas, NV 89130
702-839-2960
702-839-2962
3/14/03
3/27/03
3/27/03
NAMEFlare Main-2SUNGW02Lab BlankLCS
BILL TO:
P.O.#
PROJECT #
CONTACT:
Mr. Tom GardnerEnvironmental Technologies of Nevada,Inc.770 East Sahara AvenueLas Vegas, NV 89104
Sunrise Gas Samples
Kelly Buettner
IEJSIModified ASTM D-1945Modified ASTM D-1945Modified ASTM D-1945Modified ASTM D-1945
RECEIPTVAC/PRES.Tedlar BagTedlar Bag
NANA
CERTIFIED BY: DATE: 03/27/03
Laboratory Director
Certfication numbers: AR DEQ, CA NELAP - 0211 OCA, LA NELAP/LELAP- AI30763, NJ NELAP - CA004NY NELAP -11291, UT NELAP - 9166389892
Name of Accrediting Agency: NELAP/Florida Department of Health, Scope of Application: Clean Air Act,Accreditation number: E87680, Effective date: 07/01/02, Expiration date: 06/30/03
Air Toxics Ltd. certifies that the test results contained in this report meet all requirements of the NELAC standards
This report shall not be reproduced, except in full, without the written approval of Air Toxics Ltd
180 BLUE RAVINE ROAD, SUITE B FOLSOM, CA - 95630(916) 985-1000 . (800) 985-5955 . FAX (916) 985-1020
Page 1 of 7
LABORATORY NARRATIVEModified ASTM D-1945
Environmental Technologies of Nevada, Inc.Workorder# 0303267BR1
Two 1 Liter Tedlar Bag samples were received on March 14, 2003. The laboratory performed analysis viamodified ASTM Method D-1945 for Methane and fixed gases in natural gas using GC/FID or GC/TCD.The method involves direct injection of up to 1.0 mL of sample. With the exception of analyses conducted inaccordance with AFCEE 3.0, all reported compound quantifications were calculated from response factorsderived from the first Continuing Calibration Verification of each relevant analytical batch. See the datasheets for the reporting limits for each compound.
RequirementNormalization
Sample analysis
Sample calculation
Standard preparation
ASTM D-1945Sum of original valuesShould not differ from100.0% by more than1.0%
Equilibrate samples to20-50° F. above sourcetemperature at fieldsampling
Response factor iscalculated using peakheight for C5 andlighter compounds.
Prepared by blendingpure standards
ATL ModificationsSum of original values may range between 75-125%.
No heating of samples is performed.
Peak areas are used for all target analytes toconcentrations.
Purchased blend certified to ± 5% accuracy
quantitate
or better
Receiving Notes
There were no receiving discrepancies.
Analytical Notes
Sample Flare Main-2 was diluted due to a high level of Hydrogen Sulfide. Diluted results for Nitrogen andOxygen are not accurate and therefore not reported since ambient air concentrations of these elements arehigh. Since Nitrogen and Oxygen are not reported, results were not normalizied and do not equal 100% asper ASTM-D1945 protocol. An estimated BTU value was reported per client's request.
Due to high sulfur concentration in samples Flare Main-2 and SUNGW02 , the nickel catalyst was bypassed,resulting in a higher reporting limit of 0.1% for Carbon Monoxide and Carbon Dioxide. Sampleconcentrations were based on the response of a single point calibration for all analytes.
Sample SUNGW02 results are normalized to total 100% per ASTM D-1945 protocol.
RE-ISSUED ON MARCH 26, 2003 TO CORRECT THE DILUTION FACTOR FOR SAMPLEFLARE MAIN-2.
Definition of Data Qualifying Flags
Six qualifiers may have been used on the data analysis sheets and indicate as follows:
Page 2 of 7
J - Estimated value.E - Exceeds instrument calibration range.S - Saturated peak.Q - Exceeds quality control limits.U - Compound analyzed for but not detected above the detection limitM - Reported value may be biased due to apparent matrix interferences.
File extensions may have been used on the data analysis sheets and indicatesas follows:a-File was requantifiedb-File was quantified by a second column and detectorrl-File was requantified for the purpose of reissue
Page 3 of 7
AIR TOXICS LTD.SAMPLE NAME: Flare Main-2
ID#: 0303267BR1-01ANATURAL GAS ANALYSIS BY MODIFIED ASTM D-1945
File Name:DII. Factor
3031418R1500
Date of Collection: 3/12/03Date of Analysis: 3/14/03
CompoundRpt. Limit Amount
OxygenNitrogenCarbon MonoxideMethaneCarbon DioxideEthanePropaneIsobutaneButaneNeopentaneIsopentanePentaneC6+
Estimated BTU/Cu.F.= 550Estimated Sp. Gravity= 0.30Container Type: 1 Liter Tedlar Bag
5050
0.500.0500.500.500.500.500.500.500.500.505.0
Not DetectedNot DetectedNot Detected
54Not DetectedNot DetectedNot DetectedNot DetectedNot DetectedNot DetectedNot DetectedNot DetectedNot Detected
Page 4 of 7
AIR TOXICS LTD.SAMPLE NAME: SUNGW02
ID#: 0303267BR1-02ANATURAL GAS ANALYSIS BY MODIFIED ASTM D-1945
File Name:Oil. Factor
30314171.00
jate of Collection: 3/12/03Date of Analysis: 3/14/03
CompoundRpt. Limit Amount
OxygenNitrogenCarbon MonoxideMethaneCarbon DioxideEthanePropaneIsobutaneButaneNeopentane
IsopentanePentaneC6+
Total BTU/Cu.F.= 3.7Total Sp. Gravity= 1.0Container Type: 1 Liter Tedlar Bag
0.00100.00100.010
2377
Not Detected0.0440.24
Not DetectedNot DetectedNot DetectedNot DetectedNot Detected
6.0026Not Detected
0.066
Page 5 of 7
AIR TOXICS LTD.SAMPLE NAME: Lab Blank
ID#: 0303267BR1-03A
NATURAL GAS ANALYSIS BY MODIFIED ASTM D-1945
File Nam«:
DII. Factor3031416
1.00
Date of Collection: NADate of Analysis: 3/14/03
CompoundRpt. Limit Amount
OxygenNitrogenCarbon MonoxideMethaneCarbon DioxideEthanePropaneIsobutaneButaneNeopentane
IsopentanePentaneC6+
Total BTU/Cu.F.= NATotal Sp. Gravity= NAContainer Type: NA - Not Applicable
0.100.100.10
0.000100.100.00100.00100.00100.00100.00100.00100.00100.010
Not DetectedNot DetectedNot DetectedNot DetectedNot DetectedNot DetectedNot DetectedNot DetectedNot DetectedNot DetectedNot DetectedNot DetectedNot Detected
Page 6 of 7
AIR TOXICS LTD.SAMPLE NAME: LCS
ID#: 0303267BR1-04A
NATURAL GAS ANALYSIS BY MODIFIED ASTM D-1945
File Name:Oil. Factor
30314141.00
Date of Collection: NA
Bate of Analysis: 3/14/03
CompoundRpt. Limit
%Recovery
OxygenNitrogenCarbon MonoxideMethaneCarbon DioxideEthanePropaneIsobutaneButaneNeopentane
0.100.100.10
0.00010
0.100.0010
0.0010
0.0010
0.0010
0.0010
104100100100971009810310194
IsopentanePentaneC6+
Total BTU/Cu.F.= NATotal Sp. Gravity= NAContainer Type: NA - Not Applicable
0.00100.00100.010
9899106
Page 7 of 7