gas leak detector instruction manualleakage; gas rises towards ceiling and accumulates in areas near...
TRANSCRIPT
Introduction
Technical Parameters
This product is designed to detect explosive gases(natural gas and LPG) in the
air for houses, offices and similar places etc. It is an electrical alarm apparatus
that is located in a fixed place that works constantly that can give out a visual and
audible alarm.
Detected Flammable Gases: Natural gas(methane), LPG(liquefied petroleum gas)
Optional Type: Standalone Type
Area of Usage: Households
Operating Voltage: DC5V±10% 1A
Backup Battery(Optional): 3.7V rechargeable battery
Static Current: <110mA @ 5V
Power Consumption: <0.55W
Sensor Type: Catalytic
Alarm Set Point: 5%LEL
Alarm Tolerance: ±3%LEL
Warm-up Time: 1 minute
Response Time: ≤30 seconds
Audible Warning: Buzzer
Visual Warning: Green: System is on, Electric connection
Yellow: Fault, Sensor has lost efficacy
Red: Alarm, Gas Leakage
Loudness Level: 85dB(from the distance of 1 meter)
Body Material: ABS
Operating Temperature: 0℃ ~ +55℃
Areas of Use
It is an electrical apparatus operating constantly in households when fixedly
installed. It is used in natural gas or LPG consuming or storing places such as
residence, office, workplace, plant, storage, kitchen and bath in which gas leak
and accumulation may occur. It may not be used in boats, caravans, mobile
houses and industrial and commercial installations for which different standards
are applied.
Gas Leak Detector
Instruction Manual
※Before installing and using the product,
please read the instruction manual carefully.
AirInlet
Green LED Light
Yellow LED Light
Red LED Light
Display
USB Interface
POWER ALARM FAU LT
SELF-T ESTTest Button
Operation
It shall be attached importance to places having the biggest potential of gas
accumulation while determining location of the gas alarm device. The apparatus
shall not be located on following places:
-Over the oven and chimney hood
-Smelly places
-Near to vacuuming fan(exhaust fan etc.)
-Directly over a sink
-Closed places(e.g. inside a cupboard or behind curtain)
-Vaporous places
-Near to door or window
-A place of which temperature is under 0℃and over +55℃
-A place in which dirt and dust may block the detector
-Wet and moist places
-Gas detector shall be assembled in an area which air movements may not be
blocked by furniture or wares.
-Location of the detector shall not be very close to apertures and ventilation
channels as air stream may be greater and gas concentration may decrease.
-The apparatus shall not be assembled over or near to gas apparatuss as small
gas leakages that may lead to undesired alarms will occur when it starts to operate.
1. Plug in the apparatus.
2. Three lights(Green, Yellow, Red) flash.
Three lights
(Green, Yellow,
Red) flashPreheating
Maintenance
What to do In Case of Alarm
You may clean exterior surface of the apparatus, unplug the device before
cleaning. You may use a wet duster to clean exterior surface of the apparatus.
Never use chemical substances such as spray, polish, detergent etc. The user
shall not perform any repairing.
If the apparatus indicates an alarm signal or you smell gas odor without a signal,
keep calm and perform the following operations.
*Shut off the gas source from the main gas control-valve and/or from storage
tank(if LPG).
*Close gas valves and gas tools(i.e. cookers) starting from the closest one.
*Open the doors and windows in order to increase ventilation.
*Do not use lighter or matches, put our your cigarette. Put out all the open fires,
smoky materials, sources that may cause spark and fire, do not make them
operable once again.
*Do not touch any electrical hardware including gas detecting apparatus, do not
open or close them, do not interfere to their plugs(fuses, door bell, electric
switches etc). Leave the open and closed ones in their current position.
*Do not use mobile phone and radio-set against the risk of spark.
*Extinguish fire, if any. Extinguish all naked fire including all the smoky materials.
*Call gas distribution company from a suitable location.
9. The apparatus gives out visual and audible alarm. Visual and audible alarm
continues until ambient gas volume falls below alarm set point.
10. Apply for the service if the yellow led light on the apparatus flashes.
7. Press the test button, the three lights flash.
8. You may use the gas of a lighter to test detection of the apparatus. Keep
lighter gas upon holes of the product and wait in this position while applying
gas to the apparatus.
3. Wait for 1 minute for warm-up of the apparatus; do not apply test gas
meanwhile because it will not be detected even if it is applied.
4. In the state of warm-up, if the apparatus has voice alarm function, pressing the
test button can switch language(Chinese and English language switching).
Green led light
is always on
Preheati ng
CH4:0.0L EL
5. In the state of warm-up, long pressing the test button will skip warm-up. (Note:
Don’t skip warm-up.)
6. Warm-up finished, the green led light is always on.
Welcome to use voicegas detector, the detectoris warming up, pleasewait for one minute.
(Optionalvoicealarm)
Installation
Natural gas that is comprised of methane gas is lighter than air, in case of gas
leakage; gas rises towards ceiling and accumulates in areas near ceiling.
Therefore, for natural gas, the alarm apparatus shall be located in a position of
30 cm under the ceiling and 1.5-4 meter(s) away from gas supply. LPG that is
comprised of mixture of propane and butane is heavier than air. In case of gas
leakage, LPG falls down to ground. Therefore, for LPG, the alarm apparatus
shall be located in a position of 30 cm above the floor and 1.5-4 meter(s) away
from gas supply.
220VAC or 12VDC
220VAC or 12VDC
Related Humidity: ≤95% RH
Dimension:Φ150mm*H60mm
Considerations and Warnings
Vapor of alcohol and similar substances, spray, very intense cigarette smoke,
torch gas, cleaning agents and chemical substances with very strong odors,
very intense meal and water vapors may cause to alarm to malfunction by
misleading the apparatus.
This product is only used to reduce the accident, cannot make sure everything.
Except that use our detector in right way, pls pay more attention in your daily life
and strengthen safety and security consciousness.