16 Software • BIOS, Drivers, and Operating System Installation A. Confirm BIOS Version: Look on the Server/System Management screen in the BIOS Setup Utility to determine the installed BIOS version. Compare this to the versions at: http://www.intel.com/support/motherboards/server. If new versions are available, update the BIOS on your server. See the Techinical Product Specification on the Intel ® Server Deployment Toolkit CD for update instructions. B. Configure your RAID Controller: Use the instructions provided with the RAID controller. C. Install your Operating System: Use the instructions provided with the RAID controller and with the operating system. D. Install Operating System Drivers: With the operating system running, insert the Intel ® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Intel ® Deployment Assistant will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files. Side 2 9 Install Optical Drive and Hard Drive(s) See the documentation that came with your server chassis for drive installation. 14 Install Add-in Card[s] See the documentation that came with your server chassis for add-in card installation. For the Intel ® Server Chassis P4000 series, see the Quick Start User's Guide accompanying the chassis. 15 Finishing Up Before installing your operating system, you must finish your chassis installation, make I/O connections and plug in AC power. See your chassis documentation for AC power and grounding requirements. CAUTION: See your chassis documentation for AC power and grounding requirements. Network USB 0-1 USB 2-3 NIC1 10/100/ 1000 Mb NIC2 10/100/ 1000 Mb Video Serial A Common Problems and Solutions The system does not boot or show video at power-on. Check that the +12V CPU power connector is plugged in. Without this cable, the processors will not have any power. Only Intel ® Xeon ® E3-1200 processors, the 2 nd Generation Intel ® Core™ i3 processors, Intel ® Xeon ® E3-1200 V2 processors or the 3 rd Generation Intel ® Core™ i3 processors with 95W and less Thermal Design Power (TDP) are supported on this server board. Previous generation Intel ® Xeon ® processors are not supported. Beep code 1-5-2-1 in a system means you do not have the supported processor installed. The system generates the memory error beep code and POST diagnostic LED message {0XE0~0XEF} that indicates memory errors in early POST. Remember, all DIMMs must be: DDR3 1066/1333/1600 MHz UDIMM. From the same manufacturer. Installed beginning with DIMM A1. For a list of hardware components that have been tested with this system, see: http://www.intel.com/support/motherboards/server. 11 Attach Intrusion Switch Cable Note: For a non-Intel chassis, see your chassis documentation for intrusion switch requirements. Server Board Server Board Intrusion Switch Connector IMPORTANT NOTE: Return to your Intel ® Server Chassis Quick Start User's Guide, or your non-Intel ® chassis documentation to finish installation and configuration of your Intel ® Server Board S1200BTS. Return to this document to finish up, including software, BIOS, drivers and operating system installation. 1 2 Attach Front Panel, Serial, and USB Connections Note: For a non-Intel ® chassis, see your chassis documentation for front panel features and server board connection requirements. Internal USB/Serial Connector Detail Serial B USB Front Panel USB Floppy USB Connector Detail 13 Chassis Fan Connections For a non-Intel ® server chassis, see the "Making Connections ... Quick Reference" section below, and the documentation accompanying your chassis for specific chassis fan connection requirements. Attach fans with 4-pin connectors here. Server Board 7 Install DIMM Memory Modules To Install DIMMs: DDR3 DIMM Memory Identification: Open both DIMM socket levers. Push down firmly on the DIMM until it snaps into place and both levers close. Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot. C A D IMPORTANT! Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot. E Note location of alignment notch. B CAUTION: Avoid touching contacts when handling or installing DIMMs. DIMM notch and socket bump must align as shown. Other Memory DDR3 This server board supports up to 4 DDR3 1066/1333/1600 ECC UDIMM. CAUTION: Observe normal ESD (ElectroStatic Discharge) procedures to avoid possible damage to system components. Memory Configurations and Population Order: Memory Type: Minimum of one 1 GB, DDR3 1066/1333/1600 MHz ECC UDIMM. A C D B E Note: For additional memory configurations, see the Intel ® Server Board S1200BTS Techinical Product Specification at: http://www.intel.com/support/motherboards/server. Memory sizing and configuration is supported only for qualified DIMMs approved by Intel ® . For a list of supported memory, see the tested memory list at http://serverconfigurator.intel.com/default.aspx DIMM A2 DIMM A1 DIMM B2 DIMM B1 Intel ® Server Board S1200BTS Component Layout Note: Not all components, jumpers and connectors are described in this diagram. Refer to your Server Board Technical Product Specification on the Intel ® Server Deployment Toolkit CD for additional information. SATA 5 SATA 2 SATA 1 SATA 0 USB 4-5 Front Panel Connector SATA 4 SATA 3 SATA_SGPIO SYS FAN_3 SYS FAN_1 Processor Socket CPU Fan Connector CMOS battery HDD LED TPM SATA Key Chassis Intrusion CPU Power Connector Diagnostic LEDs SYS FAN_2 Note: Refer to the Technical Product Specification for Diagnostic LED decoder list. Slot 4 ( PCI ) 3 2 Default Recover J2G1 BIOS Recovery 3 2 Default Clear J1H3 CMOS Clear 3 2 Default J1G1 Password Clear Cleared 3 2 Default J2J1 Enabled ME Force Update Serial-A VGA NIC2 USB2 USB3 NIC1 USB0 USB1 Main Power Connector DIMM_A2 DIMM_A1 DIMM_B2 DIMM_B1 Slot 6 ( PCIe x 8 ) LP Riser Slot 5 ( PCIe x 4 ) Slot 7 ( PCIe x 8 ) USB 6 2 Reset Button NIC 2 Link/Act NIC 1 Link/Act Power Button HDD LED Power LED Front Panel Header (J1C1) Document/Tool Available Documents Technical Product Specification Monthly Specification Update Spares, Parts List, and Configuration Guide Sever Configurator Tool Software and Drivers Content In-depth technical information Technical information and issues update Supported accessories and spares list Tested peripherals and operating systems list Tested memory list Supported processors list Up-to-date firmware, driver and utility information Additional Reference documents available at: http://www.intel.com/support/motherboards/server. A complete list of accessories and spares can be found at: http://www.intel.com/support/motherboards/server (search for the document titled “Spares and Configuration Guide”.) Accessories and Order Codes Intel ® Integrated RAID Module Intel ® Integrated RAID Module Intel ® Trusted Platform Module AXXTPME3 AXXRMS2AF040 AXXRMS2LL040 Additional Reference documents available at: http://www.intel.com/support/motherboards/server ATX I/O Shield AXXTIO SATA Slim-Line DVD AXXSATADVDROM Making Connections to the Server Board ... Quick Reference = Make this connection = Make this connection D. System Fan 1 Header E. System Fan 2 Header F. System Fan 3 Header Intel ® Server Chassis P4000 series CPU/System Fan Connections A. +12V CPU Power Connector B. Main Power Connector C. Front Panel Header Required Connections Intel ® Server Chassis P4000 series = Make this connection Optional Connections H. USB 4-6 I. SATA Connectors J. SATA SGPIO K. TPM L. SATA Key M. Chassis Intrusion Header Intel ® Server Chassis P4000 series G. CPU Fan Header IMPORTANT Note: Cables should be tied for better airflow. Use cable-ties as necessary. C Front Panel Serial ATA I USB H 6 4-5 Main Power 12V CPU Power A Intrusion M SATA Key L SATA SGPIO J TPM K B CPU Fan G E Sys Fan 3 D Sys Fan 1 F Sys Fan 2 Note: For a non-Intel Chassis, see your chassis documentation for server board connection information. Note: Not all optional connections are shown in this diagram. Refer to your Server Board Service Guide, and your server chassis documentation for additional connection information. 8 Make Server Board Power Connections Attach the CPU power connector. Attach the main power connector. IMPORTANT NOTE: If you are using a non-Intel server chassis with an ATX power supply, see the documentation that came with your chassis for installation information. CAUTION: Note the location of the latch on each power cable connector and align it with the matching tab on each server board socket. Main Power Connector Detail B Latch Tab CPU Power Connector Detail A A B 1 0 Connect Hard Drives/Optical Drive to Server Board Connect SATA Data Cables to server board here. Begin cable connections at the SATA 0 location. SATA Data Cable Connector Server Board 0 4 2 Server Board 1 5 3

Upload: duonghuong

Post on 21-Aug-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

16 Software • BIOS, Drivers, and Operating System Installation

A. Confirm BIOS Version: Look on the Server/System Management screen in the BIOS Setup Utility to determine the installed BIOS version. Compare this to the versions at:http://www.intel.com/support/motherboards/server.If new versions are available, update the BIOS on your server. See the Techinical Product Specification on the Intel® Server Deployment Toolkit CD for update instructions.

B. Configure your RAID Controller: Use the instructions provided with the RAID controller.

C. Install your Operating System: Use the instructions provided with the RAID controllerand with the operating system.

D. Install Operating System Drivers: With the operating system running, insert theIntel® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Intel®Deployment Assistant will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files.

Side

2

9 Install Optical Drive and Hard Drive(s)

See the documentation that came with your server chassis for drive installation.

14 Install Add-inCard[s]

See the documentation that came with your server chassis for add-in card installation.

For the Intel® Server Chassis P4000 series, see the Quick Start User's Guide accompanying the chassis.

15 Finishing UpBefore installing your operating system, you must finish your chassis installation, make I/O connections and plug in AC power.See your chassis documentation for AC power and grounding requirements.

CAUTION: See your chassisdocumentation for AC power and grounding requirements.

Network

USB0-1

USB2-3

NIC110/100/

1000 Mb

NIC210/100/

1000 Mb

VideoSerial A

Common Problems and SolutionsThe system does not boot or show video at power-on.

• Check that the +12V CPU power connector is plugged in. Without this cable, the processors will not have any power.

• Only Intel® Xeon® E3-1200 processors, the 2nd Generation Intel® Core™ i3 processors, Intel® Xeon® E3-1200 V2 processors or the 3rd Generation Intel® Core™ i3 processors with 95W and less Thermal Design Power (TDP) are supported on this server board. Previous generation Intel® Xeon® processors are not supported. Beep code 1-5-2-1 in a system means you do not have the supported processor installed.

• The system generates the memory error beep code and POST diagnostic LED message {0XE0~0XEF} that indicates memory errors in early POST.

• Remember, all DIMMs must be: – DDR3 1066/1333/1600 MHz UDIMM. – From the same manufacturer. – Installed beginning with DIMM A1.

For a list of hardware components that have been tested with this system, see:http://www.intel.com/support/motherboards/server.

11 Attach Intrusion Switch Cable

Note: For a non-Intel chassis, see your chassis documentation for intrusion switch requirements.

ServerBoard

ServerBoard

IntrusionSwitch

Connector

IMPORTANT NOTE: Return to your Intel® Server Chassis Quick Start User's Guide, or your non-Intel® chassis documentation to finish installation and configuration of your Intel® Server Board S1200BTS.

Return to this document to finish up, including software, BIOS, drivers and operating system installation.

12 Attach Front Panel, Serial, and USB Connections

Note: For a non-Intel® chassis, see your chassis documentation for front panel features and server board connection requirements.

InternalUSB/SerialConnector

Detail

Serial B

USB

Front Panel

USB Floppy

USBConnector

Detail

13 Chassis Fan Connections

For a non-Intel® server chassis, see the "Making Connections ... Quick Reference"section below, and the documentation accompanying your chassis for specificchassis fan connection requirements.

Attach fans with 4-pin connectorshere.

ServerBoard

7 Install DIMM Memory Modules To Install DIMMs:DDR3 DIMM Memory Identification:

Open both DIMM socket levers.

Push down firmly on the DIMM until itsnaps into place and both levers close.

Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot.

C

A

D

IMPORTANT! Visually check that eachlatch is fully closed and correctlyengaged with each DIMM edge slot.

E

Note location of alignment notch.B

CAUTION: Avoid touching contacts when handling or installing DIMMs.

DIMMnotch and

socketbump must

align asshown.

OtherMemory

DDR3

This server board supports up to 4 DDR3 1066/1333/1600ECC UDIMM.

CAUTION: Observe normal ESD (ElectroStatic Discharge) procedures to avoid possible damage to system components.

Memory Configurations and Population Order:

Memory Type: Minimum of one 1 GB, DDR3 1066/1333/1600 MHz ECC UDIMM.

A

C

D B

ENote: For additional memory configurations, see the Intel® Server Board S1200BTS Techinical Product Specification at: http://www.intel.com/support/motherboards/server.

Memory sizing and configuration is supported only for qualified DIMMs approved by Intel®. For a list of supported memory, see the tested memory list athttp://serverconfigurator.intel.com/default.aspx

DIMM A2DIMM A1DIMM B2DIMM B1

Intel® Server Board S1200BTS Component Layout

Note: Not all components, jumpers and connectors are described in this diagram. Refer to your Server Board Technical Product Specification on the Intel® Server Deployment Toolkit CD for additional information.

SATA 5

SATA 2

SATA 1SATA 0

USB 4-5

Front PanelConnector

SATA 4

SATA 3

SATA_SGPIOSYS FAN_3 SYS FAN_1

Processor Socket

CPU FanConnector

CMOS battery

HDD LED

TPM

SATA Key

Chassis Intrusion

CPU PowerConnector

DiagnosticLEDs

SYS FAN_2

Note: Refer to the Technical Product Specificationfor Diagnostic LED decoder list.

Slot

4 (

PCI )

3

2Default

RecoverJ2G1

BIOSRecovery

3

2Default

ClearJ1H3

CMOSClear

3

2Default

J1G1

PasswordClear

Cleared

3

2Default

J2J1Enabled

MEForce

Update

Serial-AVGA

NIC2USB2USB3

NIC1USB0USB1

Main PowerConnector

DIM

M_A

2D

IMM

_A1

DIM

M_B

2

DIM

M_B

1

Slot

6 (

PCIe

x 8

) LP

Rise

r

Slot

5 (

PCIe

x 4

)

Slot

7 (

PCIe

x 8

)

USB 6

2

Reset Button

NIC 2Link/Act

NIC 1Link/Act

Power Button

HDD LED

Power LED

Front Panel Header(J1C1)

Document/ToolAvailable Documents

Technical Product SpecificationMonthly Specification UpdateSpares, Parts List, and Configuration Guide

Sever Configurator Tool

Software and Drivers

ContentIn-depth technical informationTechnical information and issues updateSupported accessories and spares list

Tested peripherals and operating systems listTested memory listSupported processors list

Up-to-date firmware, driver and utility information

Additional Reference documents available at:http://www.intel.com/support/motherboards/server.

A complete list of accessories and spares can be found at:http://www.intel.com/support/motherboards/server(search for the document titled “Spares and Configuration Guide”.)

Accessories and Order Codes

Intel® Integrated RAID Module

Intel® Integrated RAID Module

Intel® Trusted Platform Module AXXTPME3

AXXRMS2AF040

AXXRMS2LL040

Additional Reference documents available at: http://www.intel.com/support/motherboards/server

ATX I/O Shield AXXTIO

SATA Slim-Line DVD AXXSATADVDROM

Making Connections to the Server Board ... Quick Reference

= Make this connection

= Make this connection

D. System Fan 1 HeaderE. System Fan 2 HeaderF. System Fan 3 Header

Intel® Server ChassisP4000 seriesCPU/System Fan Connections

A. +12V CPU Power ConnectorB. Main Power ConnectorC. Front Panel Header

Required ConnectionsIntel® Server Chassis

P4000 series

= Make this connection

Optional Connections

H. USB 4-6I. SATA ConnectorsJ. SATA SGPIOK. TPML. SATA KeyM. Chassis Intrusion Header

Intel® Server ChassisP4000 series

G. CPU Fan Header

IMPORTANT Note:Cables should be tied for better airflow.Use cable-ties as necessary.

CFront Panel

Serial ATA

I

USB

H 6

4-5

Main Power

12V CPU PowerA

IntrusionM

SATA KeyL

SATA SGPIO

JTPM K

B

CPU Fan

GESys Fan 3

DSys Fan 1

FSys Fan 2

Note: For a non-Intel Chassis, see your chassis documentation for server board connection information.

Note: Not all optional connections are shown in this diagram. Refer to your Server Board Service Guide, and your server chassis documentation for additional connection information.

8 Make ServerBoard PowerConnections

Attach the CPU power connector.

Attach the main power connector.

IMPORTANT NOTE: If you are using a non-Intel server chassis with an ATX power supply, see the documentation that came with your chassis for installation information.

CAUTION: Note the location of the latch on each power cable connector and align it with the matching tab on each server board socket.

Main PowerConnector Detail

B

Latch

Tab

CPU PowerConnector Detail

AA

B

10 Connect Hard Drives/OpticalDrive to Server Board

Connect SATA Data Cablesto server board here.

Begin cable connectionsat the SATA 0 location.

SATA DataCable Connector

ServerBoard

0

4

2

ServerBoard

1

5

3