fusion prj-proposal for 10 2 class
TRANSCRIPT
![Page 1: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/1.jpg)
A Real-time Indoor Dust
Monitoring System
Fusion Project Proposal
Team Name: K2V
Tram(iET), Hoang My(iMS), Woojin Joe(iIT)
2013 Fall Semester Fusion Projects Date: Oct. 2
Advisor Professor: Woo, Jung Hun
![Page 2: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/2.jpg)
Table Of Contents
1. Backgrounds
2. Related Works
3. Project Description
4. Approach
5. Evaluation & Challenge
6. Project Schedule
![Page 3: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/3.jpg)
Backgrounds 1/3
● People lives and works inside building up to 90% of time.
● EPA warns seriousness of indoor air pollution.
● In the WHO European Region alone, exposure to particulate
matter (PM) decreases the life expectancy of every person by an
average of almost 1 year(1)
● cause of various illness: asthma, atopic dermatitis, allergy, etc.
○ The prevalence rate of child asthma(2)
■ 13.0%(‘95) - 15.8%(‘00) - 18.6%(‘05)
○ Positive correlation between indoor PM2.5 exposure and the presence of
bronchitis and asthmatic symptoms, especially during the winter season(3)
How to solve this problem?
(1) http://www.euro.who.int/en/what-we-do/health-topics/environment-and-health/air-quality/data-and-statistics
(2) 관계부처 합동 보고서, 실내공기질 관리 기본계획(2009~2013), 2009.
(3) Jonathan A. Bernstein, et. al, The health effects of nonindustrial indoor air pollution, 2008.
![Page 4: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/4.jpg)
Backgrounds 2/3
(4) UK Parliament POST NOTE, UK Indoor Air Quality, 2010.
(5) WHO, Health effects of particulate matter, 2012
![Page 5: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/5.jpg)
Backgrounds 2/2
(6) http://www.frames.gov/partner-sites/emissions-and-smoke/educational-resources/tutorial/lesson-1/particulate-matter/
(7), (8) WHO, Health effects of particulate matter, 2012
The health effects of PM10 and PM2.5 are well documented.
There is no evidence of a safe level of exposure or a threshold below which
no adverse health effects occur(8).
(6)
PM is a widespread air pollutant,
consisting of a mixture of solid
and liquid particles suspended
in the air(7).
![Page 6: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/6.jpg)
Related Works 1/3
● Existiong Sensor or Monitor Device
○ monitors Indoor dust precisely but very expensive.
○ needs professional knowledge.
○ just shows number or index of IAQ
○ doesn’t provide relevant notification in real-time.
![Page 7: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/7.jpg)
Related Works 2/3 (Standards)
(9) http://www.epa.gov/air/criteria.html
(10) http://www.sibata.co.jp/english/product_data/pdf/Dust%20Measurement%20and%20SIBATA%20Products.pdf
(11) http://oneclick.law.go.kr/CSP/CnpClsMain.laf?csmSeq=509&ccfNo=12&cciNo=2&cnpClsNo=1
● US(Ambient Air)(9)
● Japan(10)
● South Korea(11)
Location PM10(ug/m^3)
public buildings; subway, underground shopping area, airport, bus terrminal,
complex shopping mall, ... below 150
medical building below 100
Indoor Parking lot below 200
![Page 8: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/8.jpg)
Related Works 3/3
Methods of Measurement(12)
● Mass Concentration Method
● Beta-Ray Absorption Method
● Light Scattering Method
(12) http://www.sibata.co.jp/english/product_data/pdf/Dust%20Measurement%20and%20SIBATA%20Products.pdf
(13) http://eleparts.co.kr/front/download.php?file_name=%B8%D5%C1%F6%BC%BE%BC%AD.pdf
(14) http://blog.naver.com/PostView.nhn?blogId=rkr7790&logNo=150134100
Dust
Lens
Heater
Dust
Ascending Air
Current
(13)
![Page 9: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/9.jpg)
A system which
- monitors the indoor dust( > 1um) in real-time
- preserve data of PM(Particulate Matter)
- shows the data with GUI using Web Interface
- provides various notification of indoor air quality and
user’s custom monitoring options
Project Description
A Real-time Indoor Dust
Monitoring System
![Page 10: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/10.jpg)
A Real-time Indoor Dust
Monitoring System
Approach 1/2
Sensor
Boards
Indoor dust
Server
Expected Project Output(tentative)
: Sensor board(Arduino)
: Sensor part Program
: Sensor-Sever Connection Module(Program)
: Data Web Server(Raspberry Pi)
: Web Interface Program
User
PM
Dust sensor for air cleaner
![Page 11: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/11.jpg)
A Real-time Indoor Dust
Monitoring System
Approach 2/2
Sensor
Boards Server
- Finding approximate methods of measurement
- Test various indoor air pollution environment.
- Statistical Analysis for finding proper level of indoor dust.
![Page 12: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/12.jpg)
Evaluation & Challenge
Evaluation: Nothing new but more functionality
- cheap & GUI Interface with web
- real-time monitoring & monitoring options
- various notification (twitter, mail, …)
Challenge
- how to calibrate the monitored value
- how to validate accuracy of monitored value
We want to focus to find profer level of PM in indoor area.
We want to check PM data ouf our daily life in real-time.
We want to focus to find profer level of PM in indoor area.
We want to check PM data of our daily life in real-time.
![Page 13: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/13.jpg)
Project Schedule
Reseach & Preparation
for implementation
Week6(Oct.13st)
Week9(Oct. 30st)
First
Implementation
Week11(Nov. 17st)
Second
Implementation
Week14(Dec. 8th)
Deploy & Test
Week16(Dec. 18st)
Prepare
Presentation
![Page 14: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/14.jpg)
Q & A
![Page 15: Fusion prj-proposal for 10 2 class](https://reader038.vdocuments.us/reader038/viewer/2022100518/558b8ce7d8b42a787a8b468b/html5/thumbnails/15.jpg)
Thanks