Improving Your Plant’s Uptime, Output and Bottom Line Trevitest ® Mark VIII On an ongoing basis, it’s your responsibility to ensure that your plant’s relief valves are operating at peak efficiency and meeting all safety requirements. How do you do that? Right now the only way to know if a valve needs repair is if it fails or by shutting down the line and testing each valve. Either of these options will cost you - time, productivi- ty, money. That was then, this is now. With the Trevitest® Mark VIII™ diagnostic recorder you now have the ability to test and identify valves in need of repair with no operational interruptions. This technology gives you the means to accurately test every valve, performed in place, on line and under nor- mal operating pressure and temperature. What does this really mean to you? It means your plant will be able to maintain and even improve upon productivity and profitabili- ty. It means you can relax. Your valves have been Furmanited. Trevitest - the Standard in Test and Measurement In addition to its ability to keep your lines up and operational, even during the testing process, what truly sets Trevitest apart from any other diagnostic recorder is its capabil- ity to measure several types of phenomena when a user is testing most any steam, vapor and liquid safety and safety relief valves. Trevitest® Mark VIII™ sets a new standard in testing & measurement Continued on reverse side The challenge was straightfor- ward. The testing of eight, 6’’ x 10” Farris Relief Valves locat- ed on vessels containing 202 tons of liquid petroleum gas (propane) at the British Gas Llandarcy plant. In the past, the testing of each valve would take 3-4 days. With Trevitest Mark VIII, all eight were fully tested in just 16 hours with- out any interruption to the plant. Testing Times The success of this initial project has convinced British Gas to include the Trevitest System as part of its ten-year workshop and overhaul procedure. A “finger- print” will be taken of each valve in the workshop and this will then be tested in situ to assess the need for valve overhaul. Furmanite Secures Ten Year Testing Contract

Upload: naved-hava

Post on 30-Dec-2015

545 views

Category:

Documents


39 download

DESCRIPTION

Trevi test brochure of Furmanite

TRANSCRIPT

Page 1: Furmanite Trevitest Brochure

Improving Your Plant’s Uptime, Output and Bottom Line

Trevitest® Mark VIII™

On an ongoing basis, it’s your responsibility to ensure that your plant’s reliefvalves are operating at peak efficiency and meeting all safety requirements.How do you do that?

Right now the only way to know if a valve needs repair is if it fails or by shutting downthe line and testing each valve. Either of these options will cost you - time, productivi-ty, money. That was then, this is now.

With the Trevitest® Mark VIII™ diagnostic recorder you now have the ability to test andidentify valves in need of repair with no operational interruptions. This technology givesyou the means to accurately test every valve, performed in place, on line and under nor-mal operating pressure and temperature. What does this really mean to you? It meansyour plant will be able to maintain and even improve upon productivity and profitabili-ty. It means you can relax. Your valves have been Furmanited.

Trevitest - the Standard in Test and Measurement

In addition to its ability to keep your lines up and operational, even during the testingprocess, what truly sets Trevitest apart from any other diagnostic recorder is its capabil-ity to measure several types of phenomena when a user is testing most any steam, vaporand liquid safety and safety relief valves.

Trevitest® Mark VIII™sets a new standardin testing &measurement

Continued on reverse side ➔

The challenge was straightfor-ward. The testing of eight,6’’ x 10” Farris Relief Valves locat-ed on vessels containing 202 tonsof liquid petroleum gas (propane)at the British Gas Llandarcy plant.In the past, the testing of eachvalve would take 3-4 days. WithTrevitest Mark VIII, all eight werefully tested in just 16 hours with-out any interruption to the plant.

Testing Times

The success of this initial projecthas convinced British Gas toinclude the Trevitest System aspart of its ten-year workshop andoverhaul procedure. A “finger-print” will be taken of each valvein the workshop and this will thenbe tested in situ to assess theneed for valve overhaul.

Furmanite Secures TenYear Testing Contract

Page 2: Furmanite Trevitest Brochure

The Trevitest Mark VIII has the ability to measure a valve’s spindle deflection (lift poten-tiometer) or valve discharge (acoustic detection), as well as inlet pressure (pressuretransducer). This is in addition to measuring the spring relaxation force (load cell) thathas been available with previous versions.

In other words, Furmanite has engineered a state-of-the-artvalve test solution that enables users to measure pressure,lift or displacement, and sound via acoustic detection. Italso allows users to select critical measurements of forceand line pressure with amazing precision and accuracy.

With the Mark VIII, not only do you have a tool that isnotably more powerful and dynamic than anything elseavailable on the market, but it is remarkably lightweightand modular in design. This considerably enhances itsability to be used under variable plant conditions, as wellas to integrate with other specialty diagnostic equipmentrequired in user-specific applications.

Trevitest - Unlike the Rest

Traditional recorders (including all other existing testing equipment) only measure forceand sometimes pressure. Selecting appropriate force at the precise moment that a valve’sspring tension is overcome is not only difficult, but sometimes possible only through theobservance of the technician – until now.

The Trevitest’s capability to measure a valve’s spindle deflection or valve discharge viaacoustic detection serves as a marker to coincide with the force at the precise instance that avalve’s spring tension is overcome and set pressure is achieved. This new functionality resultsin the most accurate and repeatable selection pos-sible of force and line pressure, which translatesinto phenomenal set pressure accuracy.

Another feature that is unique to the TrevitestMark VIII is its proprietary software, allowingfor simplified collection and color reproductionof all calibrations and graphical traces of eachvalve tested. All of these enhancements enableFurmanite to provide customers with the mostcomprehensive valve test diagnostic recordsavailable on the market today.

Furmanite - Proactive Industry Leaders

For 75 years Furmanite has been considered the worldwide innovator and leader in notonly this critical testing and measurement field, but also for comprehensive on-site andon-line plant and pipeline maintenance. The Company’s single mission and businessgoal is to maximize asset uptime for customers. Specifically, everything Furmanite doesdirectly relates to keeping an asset up, productive and profitable; be it a pipeline, a plant,or personnel.

Furmanite’s end-to-end Safety Valve Repair Solution incorporates the Trevitest Mark VIIItechnology with superior repair and maintenance services. Whether on a daily or emer-gency basis, Furmanite’s highly trained technicians are able to provide a quality andcomprehensive solution specifically engineered to Maximize Asset Uptime. ■

Furmanite, Inc.101 Old Underwood Road ■ Building F ■ La Porte TX 77571Phone: 800-444-5572 ■ Fax: 281-842-5111

www.furmanite.com

Preliminary Document. Specifications subject tochange. Copyright © 2004 Furmanite, Inc. All rightsreserved. The Furmanite logo, Trevitest and TrevitestMark VIII are trademarks of Furmanite, Inc. MaximizingAsset Uptime is a registered service mark of Furmanite,Inc. All other trademarks, service marks, registeredtrademarks, or registered service marks mentioned inthis document are the property of their respective own-ers. Printed in USA.

Trevitest RecorderComponents■ A removable laptop

computer/recorder usingWindows 2000 OS

■ A signal conditioner andhigh performance/highspeed data acquisitionsystem (continuous highspeed data logging at upto 200k S/sec)

■ A portable color printercapable of up to 350pages on a fully chargedbattery

■ Batteries and a chargingsystem are provided forAC or DC operation

■ Transducers & cables(force, pressure, liftpotentiometer, acoustic)

■ Thermal, hydro and nuclearpower generation

■ Offshore oil and gasproduction

■ Refineries and petrochemicalplants

■ Fertilizer plants

■ Food processing plants

■ Pharmaceutical plants

■ Pulp and paper plants

Functionality acrossMultiple Industries

Furmanite holds sixTrevitest-related patents;and is accepted by safetyauthorities worldwide.

Furmanite is certified bythe national Board of Boilerand Pressure VesselInspectors to repairSection I and Section VIIIvalves (VR certified).

Furmanite is NuclearRepair (NR) certified torepair valves in the NuclearIndustry.