fully automated so you can accomplish more than ever before. · walkaway automation • continuous,...
TRANSCRIPT
T H E T H I N P R E P ® 5 0 0 0 P R O C E S S O R
Walkaway Automation • Continuous, hands-free processing with
up to 45 minutes of walkaway time.
• Carousels can be loaded at accessioning and easily transported.
• Up to 20 vials, slides and filters can be loaded at once.
• Processed slides are racked and ready for staining. Output racks can be loaded directly into select stainers and coverslippers.*
Ergonomic Benefits • Automated vial uncapping and re-capping.
• Minimal risk of repetitive strain injuries for operators.
Chain-of-Custody Verification• Barcodes on the vial are automatically
matched to the label on the slide, ensuring chain-of-custody is maintained.
Intuitive Design • User-friendly touch screen interface for real-time
progress tracking and reporting.
*Adapters may be required for some models.
Fully automated so you can accomplish more than ever before.
Visit ThinPrep.com to learn more.
Slide
1234
04/21/10 16.35
Patient Name Accession #
Slide
1234
04/21/10 16.35
Patient Name Accession #
Slide
1234
04/21/10 16.35
Patient Name Accession #
Slide
1234
04/21/10 16.35
Patient Name Accession #
00000000001238
lower text region
upper text region
00000000000000
E F F I C I E N C Y S T A R T S W I T H T H E T H I N P R E P ® 5 0 0 0 P R O C E S S O R
ThinPrep 5000 Processor Specifications
22 in(56 cm)
26 in(66 cm)
34 in(86 cm)
SS-00308-001 Rev. 002 © 2016 Hologic, Inc. All rights reserved. Hologic, The Science of Sure, ThinPrep, and associated logos are trademarks and/or registered trademarks of Hologic, Inc. and/or its subsidiaries in the United States and/or other countries. This information is intended for medical professionals in the U.S. and other markets and is not intended as a product solicitation or promotion where such activities are prohibited. Because Hologic materials are distributed through websites, podcasts and tradeshows, it is not always possible to control where such materials appear. For specific information on what products are available for sale in a particular country, please contact your Hologic representative or write to [email protected].
1. LABELING 2. LOADING 3. MATCHING/PROCESSING 4. STAINING
Barcode labels are placed on the vials and slides.
Sample vials, matching slides, and filters are loaded into the input carousel.
Barcodes are read on the ThinPrep 5000 Processor from the sample vial and matches it with the slide IDs. The sample is processed only after the match is confirmed.
Processed slides are placed in an alcohol bath and ready for staining.
Visit ThinPrep.com to learn more.
ClearancesWidth: 40 in/102 cm Height: 40 in/102 cm Depth: 36 in/92 cm
Weight 185 lbs/84 kg (approximate)
Carousel capacity Up to 20 vials, slides and filters
Output capacity 8 alcohol baths of up to 20 slides each
Stainer racks compatibility
Compatible with most commercially available stainers/coverslippers
Adapters may be required for some models
Barcode support
Vial and slide label : 1D linear barcodes (Code 128, I2 of 5,Code 39, Code 93)
2D DataMatrix barcodes, ThinPrep imager compatible 7/7 OCR
Supported sample typesGynecological
Non-gyn (Urine, Mucoid, Body Fluid, and Fine Needle Aspiration)