  • Troubleshooting Guide

    Fuller TransmissionsTRTS0920 EN-USJune 2015

  • Warnings and Precautions

    Warnings and Precautions

    Before starting a vehicle always be seated in the driver’s seat, place the transmission in neutral, set the parking brakes anddisengage the clutch.

    Before working on a vehicle place the transmission in neutral, set the parking brakes and block the wheels.

    Before towing the vehicle place the transmission in neutral, and lift the rear wheels off the ground, remove the axle shafts,or disconnect the driveline to avoid damage to the transmission during towing.

    The description and specifications contained in this service publication are current at the time of printing.

    Eaton Corporation reserves the right to discontinue or modify its models and/or procedures and to change specifications at anytime without notice.

    Any reference to brand name in this publication is made as an example of the types of tools and materials recommended for useand should not be considered an endorsement. Equivalents may be used.

    This symbol is used throughout this manual to call attention to procedures where carelessness or failure to followspecific instructions may result in personal injury and/or component damage.

    Departure from the instructions, choice of tools, materials and recommended parts mentioned in this publication may jeopardizethe personal safety of the service technican or vehicle operator.

    Warning: Failure to follow indicated procedures creates a high risk of personal injury to the service technician.

    Caution: Failure to follow indicated procedures may cause component damage or malfunction.

    Note: Additional service information not covered in the service procedures.

    Tip: Helpful removal and installation procedures to aid in the service of this unit.

    Always use genuine Eaton replacement parts.

    WARNING!

  • Table of Contents

    General Information

    How to use this Troubleshooting/Operation Guide ...... 1Transmission Identification ......................................... 2Component Identification ............................................ 4Lubricants and Sealants .............................................. 6Suggested Test Fixtures .............................................. 7

    Air System Troubleshooting

    8, 9, 10, 11, 13, 15, and 18-Speed Troubleshooting ... 8RTLO 10-Speed Troubleshooting .............................. 23Combination Cylinder Troubleshooting ..................... 33FR-1X210 Troubleshooting ....................................... 51

    Operation

    Air Line Color Chart ................................................... 64Slave Valve Preselection System ............................... 657,8,9 and 10-Speed Range Air Systems .................... 667L,8,9 and 10-Speed (2-Speed auxiliary) .................. 67RT & RTO-610,6610, 6609, and 8609 Models .......... 69Deep Reduction Air System

    (with Dash Mounted Valve) ................................ 71RT, RTO, & RTX xx607LL,

    xx608LL, and xx615 models .............................. 72Deep Reduction Air System

    (with A-6915 Roadranger Valve) ........................ 75RT, RTO, & RTX xx607LL,

    xx608LL, and xx615 Models .............................. 769 and 13-Speed Air Systems

    (Top 2 & Convertible) and 18-Speed (Top-2) .... 79RT, RTO, & RTOO xx613 and xx813 Models ............. 83RTLO-xx613 Models ................................................. 86RTLO-xx713 Models ................................................. 89RTLO-xx913 Models ................................................. 92RT0-15618 and RTLO-xx618 Models ........................ 95RTLO-xx718 Models ................................................. 99RTLO-xx918 Models ............................................... 103Combination Cylinder Air System ............................ 1077LL/DLL/MLL, 8LL, 9MLL, and 15-Speed Models .. 108Unique Air Systems ................................................. 111RT &RTO 613 and 6613 Models ............................. 112RT & RTO 613 and 6613 Models

    With A-6915 Roadranger Valve ........................ 115RT & RTO 613 and 6615 Models ............................. 1167608LL with A-6915 Roadranger Valve ................... 1197608LL Models ....................................................... 120RTLO-xx610 Speed Air System ............................... 123

    RTLO-xxX610 Models ..............................................125RTL-xx710 Speed Models ........................................129RTL-xx710 Models ..................................................130AT-1202 Auxillairy Transmission

    (with 2 Position Shift Valve) .............................134AT-1202 Auxiliary Housing (3 Position Valve) .........135

    System Components

    A-4740 Air Filter/Regulator Assembly ......................137A-5161/A-5454 Air Filter/Regulator Assembly .........138A-3546 Range Valve ................................................139A-5010/A-6909 Roadranger Valve ...........................14014651 Reduction Valve (Dash-Mounted) .................141A-5015/A-6915 Roadranger Valve ...........................142Two Position Selector Valve ....................................143A-4900/A-6913 Roadranger Valve ...........................144A-5013/A-6913 Roadranger Valve ...........................145Three Position Selector Valve ..................................147A-5510/A-6910 Roadranger Valve ...........................148Range Actuator Valve (Old Design) ..........................150Range Actuator Valve (Latest Design) .....................15119470 Poppet-Type Slave Valve ..............................152A-4688 Slave Valve ..................................................153A-5000 Slave Valve ..................................................154Range Cylinder ........................................................155Range Cylinder for 610, 6610, 6609 and 8609 ........156Dash-Mounted Deep Reduction Cylinder .................157Deep Reduction Cylinder with Roadranger Valve .....158RTLO-xx610 Model Range Cylinder Assembly ........160RTL-xx710 Model Range Cylinder Assembly ...........162Intermediate Shift Cylinder Assembly

    613 and 6613, 3-Position Selector Valve ..........164Intermediate Shift Cylinder Assembly

    613 and 6613, A-5015 Roadranger Valve .........166Combination Cylinder Assembly ..............................168Splitter Cylinder Assembly .......................................171RTLO-xx610 Model Splitter Cylinder Assembly

    (Old Design) ....................................................173RTLO-xx610 Model Splitter Cylinder Assembly

    (Latest Design) .................................................175RTL-xx710 Model Splitter Cylinder Assembly ..........177RTLO-xx613 Model Splitter Cylinder Assembly .......179RTLO-xx713 Model Splitter Cylinder Assembly .......181RTLO-xx913 Model Splitter Cylinder Assembly .......183RTO-15618 and RTLO-xx618 Model

    Splitter Cylinder Assembly ...............................185RTLO-xx718 Model Splitter Cylinder Assembly .......187RTLO-xx918 Model Splitter Cylinder Assembly .......189

  • Table of Contents

    Engineering Reference Drawings

    Basic Air System Drawings - 6610,8609, and 6609 ....................................... 191

    Basic Air System Drawings - 07L, 08, 08L, 09, and 10-Speed Models .......... 192

    Basic Air System Drawings - 07LL, 08LL, and 15 Speed Models .................. 193

    Basic Air System Drawings - 707LL, 7/908LL, 7/909LL, and 7/915 Speed Models ................................. 194

    Basic Air System Drawings - 11613, 14613, and 15613 Speed Models .................................................. 195

    Basic Air System Drawings - 6613, and 7608LL Speed Models ............................................................. 196

    Basic Air System Drawings - 18 Speed Models Left-Hand Drive ................... 197

    Basic Air System Drawings - 18 Speed Right-Hand Drive ............................. 198

  • General Information

    1

    General Information

    How to use this Troubleshooting/Operation Guide

    The purpose of this manual is to assist in the diagnosis and repair of your air system. Use this manual in conjunction with otherservice literature produced by Eaton®, including Service Bulletins, Illustrated Parts Lists, Service Manuals, and OEM service ma-terial.

    This guide provides four functions• Troubleshooting Guide: Designed to isolate and resolve air system problems.

    • System Operation and Schematics: Designed to explain a complete air system's operation.

    • System Components: Designed to explain each component's function and operation.

    • Engineering Reference Drawings: Detailed drawings with optional parts and part numbers.

  • General Information

    2

    Transmission Identification

    2-Speed Auxiliary/3-Speed and 2x2 Auxiliary

    Air Hoses

    SlaveValve

    Air Lines

    RoadrangerValve

    Range Cylinder

    Air Filter/Regulator

    Deep Reduction orSplitter Cylinder

    Air Hoses

    SlaveValve

    Air Lines

    RoadrangerRoadrangerValve

    Range Cylinder

    Air Filter/Regulator

    2-SpeedAuxiliary

    3-Speed&2X2 Auxiliary

  • General Information

    3

    General Information

    Combination Cylinder / RTLO-10 Speeds

    Combination

    Cylinder

    Air Hoses

    SlaveValve

    Air Lines

    Air Filter/Regulator

    CombinationCylinder

    RoadrangerValve

    Air Lines

    RoadrangerValve

    Range Cylinder

    Air Filter/Regulator

    RTLO-10 Speeds

    Splitter Cylinder

    CY

    L

    NO

    NC

    RangeActuatorValve

    Air Hose

  • General Information

    4

    Component Identification

    Air Filter/ Regulators

    Control Valves - Old ProductionTwo Position Selector

    A-5010

    A-3546

    UP-HIG

    H DOW

    N-LOW

    A-5510

    A-5015

    Blue

    Deep Reduction Valve14651

    A-4900

    Red

    A-5013

    Gray

    Three Position Selector

    WHEN IN LOWRANGE

    SHIFT ONLY

    DO NOTPRE-SELECT

    OUT IN

    DEP REDUCT IONE

    Gray

    8, 9, and 10 Speeds 8LL, 15, 6613 Speeds

    RT/RTLO 13 Speeds RTLO-18 SpeedsRTLO-10 Speeds

  • General Information

    5

    General Information

    Control Valves - Current Production

    Slave Valves

    Range Valves

    A-6909

    A-6910

    A-6915

    Blue

    A-6913

    Red

    A-6918

    GrayGray

    8, 9, and 10 Speeds 8LL, 15, 6613 Speeds

    RT/RTLO 13 Speeds RTLO-18 SpeedsRTLO-10 Speeds

    A-4688 - Old19470 - Obsolete A-5000 - Current

    23545

    CY

    L

    NO

    NC

    23545 - old design

    P

    SE

    XH

    4303110 - latest design

    PS

    SEX

    H

  • General Information

    6

    Lubricants and Sealants

    The use of improper sealants and lubricants during air system assembly can cause improper component operation and severetransmission damage.

    The following are the recommended sealants and lubricants to be used when assembling air system components:

    Name: Eaton® Fuller® Silicone Lubricant

    Part #: 71203 (8 oz. container)—Fleet size

    Part #: 71206 (4 cc container)—Single application

    Where Used: All O-rings and mating surfaces

    Name: Eaton® Fuller® Sealant

    Part #: 71205 (2 cc container)—Single application

    Part #: 71206 (4 cc container)—Single application

    Where Used: Air fittings and threads

  • General Information

    7

    General Information

    Suggested Test Fixtures Note: For the Automated transmission models, refer to their Troubleshooting Guides for air system diagnostics.

    5/32" Air Line

    85003 - Elbow

    12881 - 1/8" Tee85003 - Elbow

    5/32" Air Line

    5/32" Air Line

    84006 - 5/32" Push-To-Connect to 1/8" NPTF

    12881 - 1/8" Tee 12769 - 1/8" Nipple

    5/32" Air Line

    84502 - Elbow

    12881 - 1/8" Tee85002 - Elbow Assembly

    83501 - Grip Nut83001 - Compression Sleeve

    1/8" Air Line

    0-100 PSI Gauge

    0-100 PSI Gauge

    0-100 PSI Gauge

    84006 - 5/32" Push-To-Connect to 1/8" NPTF

    84006 - 5/32" Push-To-Connect to 1/8" NPTF

    Test Fixture for Range Cylinder

    Test Fixture For 5/32" Air Line

    Test fixture for 1/8" Air lines

  • Air System Troubleshooting

    8

    8, 9, 10, 11, 13, 15, and 18-Speed Troubleshooting Symptom

    • Air Leak at Shift Knob

    • Air Leak at Slave Valve

    • Air Leak from Transmission Breather or Transmission Case is Pressurized

    • Air Leak at Splitter Cylinder Cover Exhaust Port

    • No or Slow Range Shift into Low

    • No or Slow Range Shift into High

    • Range Shifts with Shift Lever in Gear

    WARNING: Use care when removing air lines or checking for air flow from disconnected lines. High pressure air mayexhaust suddenly. Wear safety glasses. Exhaust all air pressure from system before removing air filter/regulator or com-bination cylinder cover.

    Note: During all testing, the vehicle air pressure must be greater than 90 PSI (620 kPa). If during testing the pressure falls below90 PSI (620 kPa), make sure the transmission is in neutral, start the engine, and let the pressure build to governor cutoff.After the pressure reaches the governor cutoff, continue testing. The pressure is critical if the vehicle is equipped with aPressure Protection Valve that would shut off the air supply to certain air circuits if the system pressure dropped below apreset level.

    IMPORTANT: Use the following air system troubleshooting procedures for part replacement only if the symptom can be dupli-cated. If the problem is intermittent, parts that are not defective could be replaced.

    Instructions

    1. Start at “Procedures” for Step A.

    2. Based on the “Result” of the procedure, go to the corresponding “What To Do Next”.

  • Air System Troubleshooting

    9

    Air System Troubleshooting

    Procedure 1: Symptom - Air Leak at Shift KnobNormal Operation:

    • A burst of air will be exhausted from the shift knob when moving the range selector from low to high. This is the air beingexhausted from the “P” air line.

    • A burst of air will be exhausted from the shift knob when moving the splitter button rearward (shifting to low split). Thisis the air being exhausted from the “SP” air line.

    Possible Causes:

    • Incorrectly attached air lines

    • Internal leak in slave valve

    • Internal leak at insert valve

    • Internal leak at shift knob

    Table 10 Air Leak at Shift Knob

    Procedure Result What to do next

    Step A Remove lower skirt on shift knob.Check for leaking fitting at the shiftknob.

    Leak found. Repair leaking fitting or air line.

    No leak found. Go to Step B.

    Step B Check air lines to make sure all linesare connected to the proper ports onthe shift knob.

    Air lines are not connected to theproper ports.

    Connect lines properly.

    A.) Reversal of “S” and “P” lines willresult in a constant leak from the ex-haust when high range is selected.B.) Reversal of the H/L and “SP”lines will result in a constant leakwhen the splitter button is rearward.

    Air lines are connected to the properports.

    Go to Step C.

    Step C Move the range selector lever downto low range. Check for constant airflow from the exhaust “E” port.

    Constant air flow from the “E” port. Replace knob.

    No air flow from “E” port. Go to Step D.

    Step D Move the range selector up to highrange. Disconnect the small air lineconnected to the “P” port of the shiftknob. Check for air flow from theport and air line.

    Constant air is leaking from the “P”port or the “E” port.

    Repair or replace the shift knob.

    Air is coming out of the disconnect-ed air line.

    1. Verify that the air line is connectedto the slave valve “p” port.

    2. If properly connected, replace theslave valve.

    Air is not leaking from either port ordisconnected air line.

    Go to Step E.

  • Air System Troubleshooting

    10

    Step E Reattach the air line to the “P” port.Move the range selector down to lowrange and move the splitter buttonrearward. Disconnect line from the“SP” port. Check for air flowing fromthe SP port on the shift knob.

    Air is flowing from the SP line. 1. Check to make sure the “SP” lineis connected to the splitter cylindercover.

    2. If the line is properly attached,check that the insert valve (old style)is properly installed (stem facing in-ward) and that the insert valve boreis not defective.

    3. Replace the insert valve.

    Air is not flowing from the line. Repair or replace the shift knob.

    Table 10 Air Leak at Shift Knob

    Procedure Result What to do next

  • Air System Troubleshooting

    11

    Air System Troubleshooting

    Procedure 2: Symptom - Air Leak at Slave ValveNormal Operation:A momentary exhaust of air at the slave valve occurs during a range shift. The air from the low side of the range cylinder isexhausted as air pressure is applied to the high range side. Likewise, air from the high range side of the piston is exhausted as airpressure is applied to the low range side. The exhaust port is located at the slave valve to transmission mounting interface.

    Possible Causes:

    • Internal leak in range cylinder.

    • Internal leak in slave valve.

    Table 11 Air Leak at Slave Valve

    Procedure Result What to do next

    Step A Confirm that air is leaking from the ex-haust port on the slave valve and not afitting or air line.

    Air is leaking from fitting or air line. Repair or replace fitting or air line.

    Air is definitely leaking from slavevalve exhaust port.

    Go to Step B.

    Step B Move range selector down to select lowrange.Remove the 1/4" I.D. rubber air line atthe high range supply port on the rangecylinder.Feel for air flow from the open port onthe range cylinder.Notice if the air leak at the slave valveonly occurs when the transmission is inhigh range.Repeat the above test but remove thelow range air hose and check with highrange selected.

    Air is flowing from high range sup-ply port on range cylinder.

    Remove range cylinder cover andrepair leaking range piston or pis-ton seal. After repair, check forproper range operation.

    No air flow from high range port. Repair or replace slave valve.

  • Air System Troubleshooting

    12

    Procedure 3: Symptom - Air Leak from Transmission Breather or Transmission Case isPressurizedNormal Operation:There should be no measurable air flow from the transmission breather.

    Possible Causes:

    • Leak at range yoke bar O-ring

    • Leak at splitter yoke bar O-ring

    Table 12 Air Leak from Transmission Breather or Transmission Case is Pressurized

    Procedure Result What to do next

    Step A Listen for the air leak with the trans-mission shifted to both low andhigh range.

    Leak is only in low range. Remove range cylinder and inspect fordamaged range yoke bar, yoke bar O-ring, or range cylinder. Repair as neces-sary.

    Leak is in both low andhigh range.

    Remove splitter cylinder. Inspect fordamaged splitter yoke bar, O-ring, or cyl-inder. Repair as necessary.

  • Air System Troubleshooting

    13

    Air System Troubleshooting

    Procedure 4: Symptom - Air Leak at Splitter Cylinder Cover Exhaust PortNormal Operation: A burst of air will exhaust from this port when shifting into low split (the splitter button is moved rearward while in low range).

    Possible Causes:

    • Damaged/defective insert valve

    • Leak past insert valve external O-rings

    • Leak past splitter cylinder piston

    Table 13 Air Leak at Splitter Cylinder Cover Exhaust Port

    Procedure Result What to do next

    Step A (oldstyle)

    Remove insert valve. Check for contamination, dam-aged seals, or sticky movement. Check the insertvalve bore in the splitter cylinder cover for contami-nation or damage which would result in leakage pastthe insert valve O-rings.

    Contamination or damagefound.

    Repair or replace as neces-sary.

    No contamination or damagefound.

    Go to Step B.

    Step B Remove the splitter cylinder cover and piston.Check the piston bore for contamination or damage.Check the piston seals for damage.NOTE: Early production transmissions used a papergasket to seal the splitter cover to cylinder, if neces-sary, replace this configuration with the spool valvedesign which uses an O-ring.

    Contamination or damagefound.

    Repair or replace as neces-sary.

  • Air System Troubleshooting

    14

    Procedure 5: Symptom - No or Slow Range Shift into LowNormal Operation:When the range selector on the shift knob is moved down to select low range, air pressure will flow through the shift knob to the"P" port on the slave valve. The slave valve will direct air pressure through the low range 1/4" rubber hose to the range cylinder toshift the range. There will be a brief burst of air at the slave valve as the high range side of the range piston exhausts. Likewise,when high range is selected, the air pressure in the "P" will be exhausted at the shift knob. This will cause the slave valve to directair to the rear side of the range cylinder piston. The air pressure on the low range side will be exhausted at the slave valve.

    Possible Causes:

    • Incorrect air line hook up

    • Insufficient air supply to transmission

    • Damaged or defective air filter / regulator assembly

    • Damaged or defective shift knob master valve

    • Damaged or defective slave valve

    • Damaged or defective range cylinder

    • Damaged or defective range yoke or yoke bar

    • Damaged or defective range synchronizer

    • Damaged or defective gearing in auxiliary section of transmission

    Table 14 No or Slow Range Shift into Low

    Procedure Result What to do next

    Step A Place the shift lever in neutral.Check for constant air leakage at the shiftknob, slave valve, and transmission casebreather when both low and high rangehave been selected.

    Constant air leak is detected. Go to the other corresponding symp-tom first. See beginning of Air SystemTroubleshooting section.

    No constant leak is detected. Go to Step B.

    Step B Place shift lever in neutral. Move range selector up to high rangeposition. At the rear of the transmission,disconnect the 1/4" rubber air line fromthe low range supply port on the rangecylinder. Check for air flow from the lowrange port.

    Air flows from the low rangeport.

    Remove range cylinder cover and re-pair leaking range piston or piston seal.

    No air flow from low rangeport.

    Go to step C.

    Step C Check for air flow from the disconnectedair line.

    Air flows from disconnectedair line.

    Go to step F.

    No air flow from disconnect-ed line.

    Go to step D.

  • Air System Troubleshooting

    15

    Air System Troubleshooting

    Step D Install a 100 PSI air gauge in the discon-nected air line end. With the shift lever inneutral, move the range selector down toselect low range. Observe the gauge.

    The gauge read 0 PSI. Go to step F.

    The gauge reads pressure butis lower than 58 PSI or higherthan 63 PSI.

    Replace the filter/regulator and checkfor proper range operation.

    The gauge reads between 58 -63 PSI.

    Go to step E.

    Step E Confirm that shift lever is still in neutral.Have an assistant move the range selec-tor up and down between low and highrange. Does the pressure measured atthe gauge respond rapidly when goingfrom high to low?

    Pressure rapidly changes be-tween 58-63 PSI and 0 at thegauge.

    Air system appears to be operatingsatisfactory. Go to step R.

    Pressure does not changerapidly at gauge.

    1. Check for a plugged or dirty filter inthe filter/regulator assembly.

    2. Check for a pinched or obstructed1/4" rubber air line between the filter/regulator and slave valve.

    3. Check for a pinched or obstructed1/4" rubber air line between the slavevalve and the test gauge.

    4. If all are satisfactory, go to step F.

    Step F Place shift lever in neutral. At the shift knob, move the range selec-tion lever up to select high range.At the slave valve, remove the air linefrom the "P" port. (should be a blackline). Check for air flow from the discon-nected line.

    Air flows from the discon-nected line.

    1. Confirm that the air lines are con-nected to the correct ports at the shiftknob.

    2. If the lines are correct, replace theshift knob.

    No air flow from the discon-nected line.

    Go to step G.

    Step G Check for air flow from the "P" port onthe slave valve.

    Air flows from this port. Replace the slave valve.

    No air flow from this port. Go to step H.

    Table 14 No or Slow Range Shift into Low

    Procedure Result What to do next

  • Air System Troubleshooting

    16

    Step H Place the shift lever in neutral. Install a100 PSI pressure gauge in line with the"P" line. Move the range selector backand forth from low to high range. Thegauge should show rapid pressurechange.

    The gauge responds slowly. 1. Check for a restricted line betweenthe shift knob and slave valve.

    2. If the lines are correct, replace theshift knob.

    3. Check for a plugged or dirty filter inthe filter / regulator assembly.

    4. Check for a pinched or obstructed1/4" rubber air line between the filter/regulator and slave valve.

    5. Check for a pinched or obstructed airline between the slave valve and the "S"port on the shift knob.

    6. If all are good, replace the shift knob.

    The gauge rapidly moves be-tween 58-63 PSI and 0 PSI.

    Go to step I.

    Step I If possible, leave air lines attached toslave valve. Unbolt the slave valve fromtransmission side. Check for free move-ment of the plunger pin protruding fromthe case under the slave valve. The pinshould extract when the transmission isshifted into gear and retract when shiftedinto neutral.NOTE: If desired, the slave valve can beactuated and tested while unbolted fromthe transmission case. The air lines, ofcourse, must remain attached.

    Actuating plunger pin doesnot move freely.

    1. Remove actuating plunger pin andcheck for damage.

    2. Check for missing or broken spring.

    Actuating plunger pin movesfreely.

    Repair or replace slave valve and checkfor proper range operation.

    Table 14 No or Slow Range Shift into Low

    Procedure Result What to do next

  • Air System Troubleshooting

    17

    Air System Troubleshooting

    Step R If air system has been tested and foundto operate satisfactory, the auxiliary sec-tion must be removed to inspect for me-chanical problem.Remove auxiliary section and inspectfor:•Binding of range yoke bar or piston•Damaged or defective range yoke•Damaged or defective range synchro-nizer •Cracked countershaft weld resulting ingear turning on shaft•Damaged or defective range slidingclutch•Auxiliary section gearing out of time

    Table 14 No or Slow Range Shift into Low

    Procedure Result What to do next

  • Air System Troubleshooting

    18

    Procedure 6: Symptom - No or Slow Range Shift into HighNormal Operation:When the range selector on the shift knob is moved down to select low range, air pressure will flow through the shift knob to the'P" port on the slave valve. The slave valve will direct air pressure through the low range 1/4" rubber supply hose to the rangecylinder to shift the range. There will be a brief burst of air at the slave valve as the high range side of the range piston exhausts.

    Likewise, when high range is selected, the air pressure in the "P" will be exhausted at the shift knob. This will cause the slave valveto direct air to the rear side of the range cylinder piston. The air pressure on the low range side will be exhausted at the slave valve.

    Possible Causes:

    • Incorrect air line hook up

    • Insufficient air supply to transmission

    • Plugged filter

    • Incorrect regulator pressure

    • Damaged or defective shift knob master valve

    • Damaged or defective slave valve

    • Damaged or defective range cylinder

    • Damaged or defective range yoke or yoke bar

    • Damaged or defective range synchronizer

    • Damaged or defective gearing in auxiliary section of transmission

    Table 15 No or Slow Range Shift into High

    Procedure Result What to do next

    Step A Place the shift lever in neutral.Check for constant air leakage at the shiftknob, slave valve, and transmission casebreather when both low and high rangehave been selected.

    Constant air leak is detected. Go to the other corresponding symp-tom first. See beginning of Air SystemTroubleshooting section.

    No constant leak is detected. Go to Step B.

    Step B Place shift lever in neutral. Move range selector down to low rangeposition.At the transmission rear, disconnect the1/4" rubber air line from the range cylin-der high range supply port.Check for air flow from the cylinder highrange port.

    Air flows from the high rangeport.

    Remove range cylinder cover and re-pair leaking range piston or piston seal.After repair, check for proper range op-eration.

    No air flow from high rangeport.

    Go to step C.

    Step C Check for air flow from the disconnectedair line.

    Air flows from disconnectedair line.

    Go to step F.

    No air flow from disconnect-ed line.

    Go to step D.

  • Air System Troubleshooting

    19

    Air System Troubleshooting

    Step D Install a 100 PSI air gauge in the discon-nected air line end. With the shift lever inneutral, move the range selector up toselect high range. Observe the gauge.

    The gauge reads 0 PSI. Go to step F.

    The gauge reads pressure butis lower than 58 PSI or higherthan 63 PSI.

    Replace the filter/regulator and checkfor proper range operation.

    The gauge reads between 58 -63 PSI.

    Go to step E.

    Step E Confirm that shift lever is still in neutral.Have an assistant move the range selec-tor up and down between low and highrange. Does the pressure measured atthe gauge respond rapidly when goingfrom high to low.

    Pressure rapidly changes be-tween 58-63 PSI and 0 at thegauge.

    Air system appears to be operatingsatisfactory. Go to step R.

    Pressure does not changerapidly at gauge.

    1. Check for a plugged or dirty filter inthe filter/regulator assembly.

    2. Check for a pinched or obstructed 1/4" rubber air line between the filter/reg-ulator and slave valve.

    3. Check for a pinched or obstructed 1/4" rubber air line between the slavevalve and the test gauge.

    4. If all are satisfactory, go to step F.

    Step F Place shift lever in neutral. At the shift knob, move the range selec-tion lever up to select high range.At the slave valve, remove the air linefrom the "P" port. (should be black line).Check for air flow from the disconnectedline.

    Air flows from the discon-nected line.

    1. Confirm that the air lines are con-nected to the correct ports at the shiftknob.

    2. If the lines are correct, replace theshift knob.

    No air flow from the discon-nected line.

    Go to step G.

    Step G Check for air coming out of the slavevalve "P" port.

    Air flows from this port. Replace the slave valve.

    No air flow from this port. Go to step H.

    Table 15 No or Slow Range Shift into High

    Procedure Result What to do next

  • Air System Troubleshooting

    20

    Step H Place the shift lever in neutral. Install a100 PSI pressure gauge in line with the"P" line. Move the range selector backand forth from low to high range. Thegauge should show rapid pressurechange.

    The gauge responds slowly. 1. Check for a restricted line betweenthe shift knob and slave valve.

    2. Check for a restricted exhaust porton the shift knob.

    3. Check for a plugged or dirty filter inthe filter/regulator assembly.

    4. Check for a pinched or obstructed1/4" rubber air line between the filter/regulator and slave valve.

    5. Check for a pinched or obstructed airline between the slave valve and the "S"port on the shift knob.

    6. If all are good, replace the shift knob.

    The gauge rapidly moves be-tween 58-63 PSI and 0 PSI.

    Go to step I.

    Step I If possible, leave air lines attached toslave valve.Unbolt the slave valve from transmissionside.Check for free movement of the plungerpin protruding from the case under theslave valve. The pin should extract whenthe transmission is shifted into gear andretract when shifted into neutral.If desired, the slave valve can be actuat-ed and tested while unbolted from thetransmission case. The air lines, ofcourse, must remain attached.

    Actuating plunger pin doesnot move freely.

    1. Remove actuating plunger pin andcheck for damage.

    2. Check for missing or broken spring.

    Actuating plunger pin movesfreely.

    Repair or replace slave valve and checkfor proper range operation.

    Table 15 No or Slow Range Shift into High

    Procedure Result What to do next

  • Air System Troubleshooting

    21

    Air System Troubleshooting

    Step R If air system has been tested and foundto operate satisfactory, the auxiliary sec-tion must be removed to inspect for me-chanical problem.Remove auxiliary section and inspectfor:•Binding of range yoke bar or piston•Damaged or defective range yoke•Damaged or defective range synchro-nizer•Cracked countershaft weld resulting ingear turning on shaft•Damaged or defective range slidingclutch•Auxiliary section gearing out of time

    Table 15 No or Slow Range Shift into High

    Procedure Result What to do next

  • Air System Troubleshooting

    22

    Procedure 8: Symptom - Range Shifts with Shift Lever in GearNormal Operation: Range shifts should only occur when the shift lever is in neutral. The range selector can be moved up or down while the shift leveris in a gear position, but the shift will not occur until the shift lever is moved to neutral.

    Possible Causes:

    • Worn or missing actuating pin or air valve shaft

    • Worn shift rail

    Procedure:If the range has been confirmed to shift with the shift lever in gear, unbolt the slave valve from the side of the transmission. Con-firm that the actuating pin is present and that it is the proper part number for the corresponding slave valve. If correct, remove theshift bar housing assembly and check for a worn or damaged air valve shaft or worn shift rails. Replace necessary parts.

  • Air System Troubleshooting

    23

    Air System Troubleshooting

    RTLO 10-Speed Troubleshooting

    Confirm Correct Components and Plumbing• A-5454 Air Filter/Regulator on the range cylinder cover.

    • 1/4 inch air hose from the air filter/regulator to the splitter cylinder cover (iron port).

    • A red air line from the air filter/regulator to the tee in the range actuator valve "S" port on the shift bar housing.

    • A red air line from the tee to the A-5510/A-6910 Roadranger valve "S" port.

    • A black air line from the range actuator valve "P" port to the range cylinder.

    • A blue air line from the Roadranger A-5510/A-6910 valve "SP" port to the splitter cylinder cover (brass port.)

    WARNING: Prior to removing the air module, exhaust the air from it. Failure to exhaust the air module may result inpersonal injury or damage to parts from the sudden release of air.

    WARNING: Use care when removing the test port pipe plugs. If air pressure is present on the plug, it can become aprojectile during removal. When removing the “L” plug or “H” plug, pressure can be shut off by selecting the oppositerange mode. If removing the “F” plug, exhaust the air to the module inlet.

    CY

    L

    NO

    NC

    Air Hose

    Blue Air Line

    A-5454Air Filter/Regulator

    Black Air Line

    Red Air Line

    Red Air Line

  • Air System Troubleshooting

    24

    Air Filter/ Regulator Test

    Figure 1 Figure 2

    Table 1 Air Filter/Regulator Test

    Step Procedure Result What to do next

    A Place the transmission shift leverin neutral.

    B Start the engine and wait for theair system pressure to reach gov-ernor cut off (90 to 125 PSI.)

    C Turn the engine off.

    If at any time during testing thetruck's air pressure falls below 90PSI; restart the engine, wait for airpressure to reach governor pres-sure, turn the engine off, and con-tinue testing.

    D Make sure the splitter control but-ton is rearward.

    E Remove the two (2) screws on theRoadranger valve cover and pullthe cover down.

    F Disconnect the blue air line fromthe "SP" port.

    G Install the correct test fixture foryour air line size in the "SP" line.

  • Air System Troubleshooting

    25

    Air System Troubleshooting

    H Move the splitter control buttonforward to overdrive. The air pres-sure gauge should read between58 and 63 PSI.

    Air pressure is outside the 58 to63 PSI range and the truck's airsystem pressure is 90 to 125 PSI.

    Replace the A-5454 Filter/Regulator.

    Air pressure slowly comes up tobetween 58 and 63 PSI.

    Inspect the red air line from the filter/regulatorto the range actuator valve and the red air linefrom the range actuator valve to the A-5510/A-6910 Roadranger valve for restrictions

    R Remove the test fixture. Assemblethe Roadranger valve.

    Table 1 Air Filter/Regulator Test

    Step Procedure Result What to do next

  • Air System Troubleshooting

    26

    Range System Test

    If water or oil is found in an insert valve, remove both insert valves, the filter/regulator, the range cylinder cover, and the rangepiston. Clean everything and replace the range piston O-rings and range cylinder cover gasket. Apply silicone grease to the ex-ternal range piston O-ring and the insert valve O-rings. Assemble and test.

    Note: If you replace or repair any parts, return to Step A after completion

    Figure 3 Figure 4

    Table 2 Range System Test

    Step Procedure Result What to do next

    A Move the transmission shift lever inneutral away from the driver to the topgear rail position.

    B Remove the black air line from therange cylinder cover.

    C Check for air flow out of the black airline.

    There is no air flow from the black airline.

    Go to step D.

    There is air flow. Check the range actuator valve retain-ing bolts. Tighten any loose bolts andcheck again for air flow. If air flow con-tinues, remove the range actuatorvalve retaining bracket bolts. Push thebutton all the way into the valve. If airflow continues, replace the range actu-ator valve. If air flow stops when therange actuator valve is manually oper-ated, remove the actuating pin (lift itout with a magnet). Check the pin forwear. It should be 1.029 to 1.032 inch-es long. If it is not, replace the pin. Ifthe pin length is correct, refer to theservice manual for shift bar housinginspection.

  • Air System Troubleshooting

    27

    Air System Troubleshooting

    D Check for air flow from the range cyl-inder port.

    There is no air flow from the port. Go to step E.

    There is air flow. Remove the insert valve retaining plugfrom the range cylinder cover bottom.The insert valve will be blown out ofthe cover. Clean the insert valve, usingcompressed air and apply siliconegrease to the external O-rings. As-semble and check for air flow from theport. If air flow persists, replace theinsert valve.

    E Install the correct test fixture, for yourair line size, in the range cylinder port.

    F Move the transmission shift lever to-ward the driver (center rail.) The airpressure should rapidly be between 58and 63 PSI.

    Air pressure rapidly comes up to be-tween 58 and 63 PSI.

    Remove the test fixture and connectthe black air line to the range cylinder.If air pressure does rapidly come up tobetween 58 and 63 PSI, remove theactuating pin (lift it out with a magnet).The pin should be between 1.029 and1.032 inches long. If it is not, replaceit. If the pin length is correct, refer tothe service manual for shift bar hous-ing inspection.

    Air pressure does not rapidly come upto between 58 and 63 PSI.

    Inspect the black air line from therange actuator valve "CYL" port for re-strictions.If there are no restrictions,remove the range actuator valve re-taining bolt. Push the button all theway into the valve and release it. If airpressure does not rapidly come up tobetween 58 and 63 PSI, replace therange actuator valve.

    Table 2 Range System Test

    Step Procedure Result What to do next

  • Air System Troubleshooting

    28

    G Listen for a range shift while movingthe transmission shift lever from neu-tral to the top gear rail and back towardthe driver into the center rail. If there isno range shift, move the transmissionshift lever back and forth again andcheck for a momentary exhaust fromthe insert valve retaining plug in therange cylinder cover bottom.

    There is no range shift and there ismomentary exhaust from both insertvalves.

    Remove the range cylinder cover. Ifthe piston is stuck from rust and con-tamination, remove the piston, cleanthe cylinder, replace the O-rings, andassemble. Clean the insert valve, usecompressed air and apply siliconegrease to the external O-rings. As-semble and test.

    There is no momentary exhaust. Remove the insert valve retaining plugfrom the range cylinder cover bottom.The insert valve will be blown out ofthe cover. Clean the insert valve, usecompressed air and apply siliconegrease to the external O-rings. Assem-ble and test. If there is still no momen-tary exhaust, replace the insert valve.

    There is momentary exhaust. Move the transmission shift lever inneutral back and forth again and checkfor momentary exhaust from the insertvalve retaining plug on the range cylin-der cover side. Continue to step I.

    I Move the transmission shift lever inneutral toward the driver to the centerrail. Check both insert valve retainingplugs for continuous air flow from theexhaust port.

    There is air flow. Remove the insert valve retaining plug.The insert valve will be blown out ofthe cover. Clean the insert valve, usecompressed air and apply siliconegrease to the external O-rings. As-semble and check for air flow. If airflow persists, replace the insert valve.If air flow persists with a new insertvalve, remove the range cylinder coverand inspect the range piston O-ringsfor damage or contamination and therange piston for cracks.

    There is no air flow. Go to step J.

    J Move the transmission shift lever inneutral away from the driver to the topgear rail. Check both insert valve re-taining plugs for continuous air flowfrom the exhaust port.

    There is air flow. Remove the insert valve retaining plug.The insert valve will be blown out ofthe cover. Clean the insert valve, usecompressed air and apply siliconegrease to the external O-rings. As-semble and check for air flow. If airflow persists, replace the insert valve.

    There is no air flow. Go to step K.

    Table 2 Range System Test

    Step Procedure Result What to do next

  • Air System Troubleshooting

    29

    Air System Troubleshooting

    K With the transmission shift lever inneutral, toward the driver in the centerrail, remove the breather or breatherhole plug on the shift bar housing.Check for air flow from the hole in theshift bar housing. If there is airflowmove the transmission shift lever inneutral, away from the driver, to thetop gear rail.

    Air flow stopped. Refer to the service manual and re-place the range piston shaft to rangecylinder O-ring.

    Air flow did not stop. Refer to the service manual and re-place the splitter piston shaft to splittercylinder O-ring.

    R If the insert valves were not removedand cleaned during the test, removethem now (remove the insert valve re-taining plugs.) The insert valves willbe blown out the cover. Clean the in-sert valve, use compressed air and ap-ply silicone grease to the external "O"rings. Assemble and test. The rangeportion of the test is now complete.

    Table 2 Range System Test

    Step Procedure Result What to do next

  • Air System Troubleshooting

    30

    Splitter System Test

    If you replace or repair any parts , return to Step A after completion

    Ffigure 1 Figure 2

    Figure 3

    Table 3 Splitter System Test

    Step Procedure Result What to do next

    A Wipe off the area around the insertvalve exhaust port.

    B Move the control button back andforth several times to clear the ex-haust port.

    C Make sure the control button is rear-ward. Loosen the control air line re-taining nut at the splitter cylinder.

  • Air System Troubleshooting

    31

    Air System Troubleshooting

    D Remove the loosened control air lineand check for air flow from the cylin-der fitting.

    There is no air flow. Go to step E.

    There is air flow. Remove the insert valve and clean us-ing compressed air. Then apply sili-cone grease to the o-rings andrecheck for airflow.

    E Install, between the control line andthe cylinder fitting, the correct test fix-ture for your air line size.

    F Move the control button forward. Air pressure rapidly changes to be-tween 58 and 63 PSI and the truck'sair system is 90 to 125 PSI.

    Go to next step G.

    Air pressure does not change to be-tween 58 and 63 PSI and the truck'sair system is 90 to 125 PSI.

    Inspect the control air line for restric-tions.

    G Check the insert valve exhaust port forleakage.

    No leakage is detected. Go to next step H.

    Leakage is detected. Go to Step L.

    H Move the control button rearward andlisten for the shift.

    There is a shift. Go to next step I.

    There is no shift or a delayed shift. Go to Step L.

    I Check the exhaust port for leakage. No leakage is detected. Go to next step J.

    Leakage is detected. Go to Step L.

    J Move the control button forward andlisten for the shift.

    There is a shift. Go to next step K.

    There is no shift or a delayed shift. Go to Step L.

    K If there is air pressure at the controlline, move the control button rearwardand remove the test fixture. Connectthe control line to the cylinder.

    L Remove the insert valve retainingplug. The insert valve will be blownout of the cover (note valve orienta-tion.)

    There is no water and/or oil blown out. Go to next step M.

    Water and/or oil is blown out. Remove the cylinder cover and cleanthe cover and cylinder. Replace thecylinder cover gasket with a new gas-ket. Install cover.

    M Clean insert valve using compressedair.

    Table 3 Splitter System Test

    Step Procedure Result What to do next

  • Air System Troubleshooting

    32

    N Install the insert valve, as noted inStep L, and replace the retaining plug.

    O Check the insert valve exhaust port forleakage.

    No leakage is detected. Go to next step P.

    Leakage is detected. Replace the insert valve.

    P Move the control button forward andlisten for the shift.

    There is a shift. Go to next step Q.

    There is no shift or a delayed shift. Replace the insert valve.

    Q Check the insert valve exhaust port forleakage.

    No leakage is detected. Go to next step R.

    Leakage is detected. Replace the insert valve.

    R Move the control button rearward andlisten for the shift

    There is a shift. Go to next step S.

    There is no shift or a delayed shift. Replace the insert valve.

    S Check the insert valve exhaust port forleakage.

    No leakage is detected. Go to next step T.

    Leakage is detected. Disassemble (see service manual)and inspect splitter/reduction pistonO-ring and piston to shaft seal.

    T Move the control button forward andlisten for the shift.

    There is a shift. Go to next step V.

    There is no shift or a delayed shift. Disassemble (see service manual)and inspect splitter/reduction pistonO-ring and piston to shaft seal.

    V The air system test procedure is nowcomplete and the air system has beenconfirmed to be operating correctly. Ifperformance irregularities persist,they are not caused by the air system.

    Table 3 Splitter System Test

    Step Procedure Result What to do next

  • Air System Troubleshooting

    33

    Air System Troubleshooting

    Combination Cylinder Troubleshooting

    The symptoms listed below are covered on the following pages. Before beginning any of those troubleshooting procedures, placethe transmission in neutral and move the range selection lever from low to high. Listen for any constant air leak from the shiftknob, air module base (exhaust), or transmission breather. If a constant leak is heard, go to that particular leak troubleshootingprocedure first.

    If you do not see the symptom you need to correct, refer to the General Troubleshooting chart.

    Symptom

    • Air Leak from Air Module Base (Exhaust Leak)

    • No or Slow Range Shift into High (Shift into low range is good)

    • No or Slow Range Shift into Low (Shift into high range is good)

    • Constant Air Leak from Shift Knob

    • Range Shifts in Gear

    • Air Leak from Transmission Breather or Transmission Case is Pressurized

    Note: Use the air system troubleshooting procedures for part replacement only if the symptom can be duplicated. If the problemis intermittent, parts that are not defective could be replaced.

    Note: During all testing, the vehicle air pressure must be greater than 90 PSI (620 kPa). If during testing the pressure falls below90 PSI (620 kPa), make sure the transmission is in neutral, start the engine and let the pressure build to governor cutoff.After the pressure reaches the governor cutoff, continue testing. The pressure is critical if the vehicle is equipped with a ve-hicle air system Pressure Protection Valve that would shut off the air supply to certain air circuits if the system pressuredropped below a preset level.

    Note: A 0-150 PSI (0-1034 kPa) air gauge with a 1/16” male pipe thread fitting attachment is required for some of the test proce-dures.

    WARNING: Prior to removing the air module, exhaust the air from it. Failure to exhaust the air module may result inpersonal injury or damage to parts from the sudden release of air.

    WARNING: Use care when removing the test port pipe plugs. If air pressure is present on the plug, it can become aprojectile during removal. When removing the “L” plug or “H” plug, pressure can be shut off by selecting the oppositerange mode. If removing the “F” plug, exhaust the air to the module inlet.

  • Air System Troubleshooting

    34

    Procedure 1: Symptom - Air Leak at Shift KnobNormal operation:A burst of air will be exhausted from the shift knob when moving the range selector from low to high. This is the air being exhaust-ed from the "P" air line.

    A burst of air will be exhausted from the shift knob when moving the deep reduction button rearward (shifting out of deep reduc-tion).This is the air being exhausted from the “SP” air line.

    Possible causes:

    • Incorrectly attached air lines

    • Internal leak in slave valve

    • Internal leak at insert valve

    • Internal leak at shift knob

    Table 1 Air Leak at Shift Knob

    Procedure Result What to do next

    Step A Remove lower skirt on shift knob. Checkfor leaking fitting at the shift knob.

    Leak found. Repair leaking fitting or airline.

    No leak found. Go to step B.

    Step B Check air lines to make sure all lines areconnected to the proper ports on the shiftknob. Reversal of “S” and “P” lines willresult in a constant leak from the exhaustwhen high range is selected. Reversal ofthe H/L and “SP” lines will result in a con-stant leak when the deep reduction but-ton is rearward.

    Air lines are not connected to the properports.

    Connect lines properly.

    Air lines are connected to proper ports. Go to step C.

    Step C Move the range selector lever down toLow range. Check for constant air flowfrom the exhaust “E” port.

    Constant air flow from “E” port. Replace knob.

    No air flow from “E” port. Go to Step D.

    Step D Move the range selector up to high range.Disconnect the small air line connectedto the “P” port of the shift knob. Checkfor air flow from the port and air line.

    Constant air is leaking from the “P” portor the “E” port.

    Repair or replace the shiftknob.

    Air is coming out of the disconnectedair line.

    1. Verify that the air line isconnected to the slave valve“p” port.

    2. If properly connected, re-place the slave valve.

    Air is not leaking from either port or dis-connected air line.

    Go to Step E.

  • Air System Troubleshooting

    35

    Air System Troubleshooting

    Step E Reattach the air line to the “P” port. Movethe range selector down to low range andmove the deep reduction button rear-ward. Disconnect the air line from the“SP” port. Check for air flowing from theSP line.

    Air is flowing from the SP line. 1. Check to make sure the“SP” line is connected to thedeep reduction cylinder cov-er.

    2. If the line is properly at-tached, check that the insertvalve is properly installed(stem facing inward) andthat the insert valve bore isnot defective.

    3. Replace the insert valve.

    Air is not flowing from the line. Repair or replace the shift-knob.

    Table 1 Air Leak at Shift Knob

    Procedure Result What to do next

  • Air System Troubleshooting

    36

    Procedure 2: Symptom - Air Leak at Slave ValveNormal operation:A momentary exhaust of air at the slave valve occurs during a range shift. The air from the low side of the range cylinder is ex-hausted as air pressure is applied to the high range side. Likewise, air from the high range side of the piston is exhausted as airpressure is applied to the low range side. The exhaust port is located at the slave valve to transmission mounting interface.

    Possible Causes:

    • Internal leak in range cylinder

    • Internal leak in slave valve.

    Table 2 Air Leak at Slave Valve

    Procedure Result What to do next

    Step A Confirm that air is leaking from theexhaust port on the slave valve andnot a fitting or air line.

    Air is leaking from fitting or air line. Repair or replace fitting or air line.

    Air is definitely leaking from slavevalve exhaust port.

    Go to Step B.

    Step B Move range selector down to selectlow range. Remove the 1/4” I.D.rubber air line at the high range sup-ply port on the range cylinder. Feelfor air flow from the open port onthe range cylinder. Note: If the airleak at the slave valve only occurswhen the transmission is in highrange, repeat the above test, but re-move the low range air hose andcheck with high range selected.

    Air is flowing from high range sup-ply port on range cylinder.

    Remove range cylinder cover and re-pair leaking range piston or piston seal.After repair, check for proper range op-eration.

    No air flow from high range port. Repair or replace slave valve.

  • Air System Troubleshooting

    37

    Air System Troubleshooting

    Procedure 3: Symptom - Air Leak from Transmission Breather or Transmission Case isPressurizedNormal Operation:There should be no measurable air flow from the transmission breather.

    Possible causes:

    • Leak at range yoke bar O-ring

    • Leak at deep reduction yoke bar O-ring

    Table 3 Air Leak from Transmission Breather or Transmission Case is Pressurized

    Procedure Result What to do next

    Step A Listen for the air leak with the trans-mission shifted to both low and highrange.

    Leak is only in low range. Remove range cylinder and inspectfor damaged range yoke bar, yoke barO-ring, or range cylinder. Repair asnecessary.

    Leak is in both low and high range. Remove deep reduction cylinder. In-spect for damaged deep reductionyoke bar, O-ring, or cylinder. Repairas necessary.

  • Air System Troubleshooting

    38

    Procedure 4: Symptom: Air Leak at Deep Reduction Cylinder Cover Exhaust PortNormal operation:A burst of air will exhaust from this port when shifting into deep reduction (the deep reduction button is moved forward while inlow range).

    Possible causes:

    • Damaged/defective insert valve

    • Leak past insert valve external O-rings

    • Leak past deep reduction cylinder piston

    Table 4 Air Leak at Deep Reduction Cylinder Cover Exhaust Port

    Procedure Result What to do next

    Step A Remove insert valve. Check for con-tamination, damaged seals, or stickymovement. Check the insert valvebore in the deep reduction cylindercover for contamination or damagewhich would result in leakage pastthe insert valve O-rings.

    Contamination or damage found. Repair or replace as necessary.

    No contamination or damage found. Go to step B.

    Step B Remove the deep reduction cylindercover and piston. Check the pistonbore for contamination or damage.Check the piston seals for damage.NOTE: Early production transmis-sions used a paper gasket to seal thepiston to the yoke bar, if necessary,replace this configuration with thecurrent design which uses an O-ring.

    Contamination or damage found. Repair or replace as necessary.

  • Air System Troubleshooting

    39

    Air System Troubleshooting

    Procedure 5: Symptom - No or Slow Range Shift into LowNormal Operation:When the range selector on the shift knob is moved down to select low range, air pressure will flow through the shift knob to the‘P port on the slave valve. The slave valve will direct air pressure through the low range 1/4” rubber hose to the range cylinder toshift the range. There will be a brief burst of air at the slave valve as the high range side of the range piston exhausts. Likewise,when high range is selected, the air pressure in the “P” will be exhausted at the shift knob. This will cause the slave valve to directair to the rear side of the range cylinder piston. The air pressure on the low range side will be exhausted at the slave valve.

    Possible Causes:

    • Incorrect air line hook up

    • Insufficient air supply to transmission

    • Damaged or defective air filter / regulator assembly

    • Damaged or defective shift knob master valve

    • Damaged or defective slave valve

    • Damaged or defective range cylinder

    • Damaged or defective range yoke or yoke bar

    • Damaged or defective range synchronizer

    • Damaged or defective gearing in auxiliary section of transmission

    Table 5 No or Slow Range Shift into Low

    Procedure Result What to do next

    Step A Place the shift lever in neutral. Checkfor constant air leakage at the shiftknob, slave valve, and transmissioncase breather when both low andhigh range have been selected.

    Constant air leak is detected. Go to the other corresponding symp-tom first. See beginning of Air SystemTroubleshooting section.

    No constant leak is detected. Go to step B.

    Step B Place shift lever in neutral. Moverange selector up to high range posi-tion. At the rear of the transmission,disconnect the 1/4” rubber air linefrom the low range supply port on therange cylinder. Check for air flowfrom the low range port.

    Air flows from the low range port. Remove range cylinder cover and re-pair leaking range piston or pistonseal.

    No air flow from low range port. Go to step C.

    Step C Check for air flow from the discon-nected air line.

    Air flows from disconnected air line. Go to step F.

    No air flow from disconnected line. Go to step D.

  • Air System Troubleshooting

    40

    Step D Install a 100 PSI air gauge in the dis-connected air line end. With the shiftlever in neutral, move the range se-lector down to select low range andobserve the gauge.

    The gauge read 0 PSI. Go to step F.

    The gauge reads pressure but is low-er than 58 PSI or higher than 63 PSI.

    Replace the filter/regulator and checkfor proper range operation.

    The gauge reads between 58 - 63PSI.

    Go to step E.

    Step E Confirm that shift lever is still in neu-tral. Have an assistant move therange selector up and down betweenlow and high range. Does the pres-sure measured at the gauge respondrapidly when going from high to low.

    Pressure rapidly changes between58-63 PSI and 0 at the gauge.

    Air system appears to be operatingsatisfactory. Go to step R.

    Pressure does not change rapidly atgauge.

    1. Check for a plugged or dirty filter inthe filter/regulator assembly.

    2. Check for a pinched or obstructed1/4” rubber air line between the filter/regulator and slave valve.

    3. Check for a pinched or obstructed1/4” rubber air line between the slavevalve and the test gauge.

    4. If all are satisfactory, go to step F.

    Step F Place shift lever in neutral. At theshift knob, move the range selectionlever up to select high range. At theslave valve, remove the air line fromthe “P” port (should be black line).Check for air flow from the discon-nected line.

    Air flows from the disconnected line. 1. Confirm that the air lines are con-nected to the correct ports at the shiftknob.

    2. If the lines are correct, replace theshift knob.

    No air flow from the disconnectedline.

    Go to step G.

    Step G Check for air flow from the “P” por-tion the slave valve.

    Air flows from this port. Replace the slave valve.

    No air flow from this port. Continue to step H.

    Table 5 No or Slow Range Shift into Low

    Procedure Result What to do next

  • Air System Troubleshooting

    41

    Air System Troubleshooting

    Step H Place the shift lever in neutral. Installa 100 PSI pressure gauge in line withthe “P” line. Move the range selectorback and forth from low to highrange. The gauge should show rapidpressure change.

    The gauge responds slowly. 1. Check for a restricted line betweenthe shift knob and slave valve.

    2. Check for a restricted exhaust porton the shift knob.

    3. Check for a plugged or dirty filter inthe filter / regulator assembly.

    4. Check for a pinched or obstructed 1/4” rubber air line between the filter/regulator and slave valve.

    5. Check for a pinched or obstructedair line between the slave valve and the“S” port on the shift knob.

    6. If all are good, replace the shiftknob.

    The gauge rapidly moves between58-63 PSI and 0 PSI.

    Go to step I.

    Step I If possible, leave air lines attached toslave valve. Unbolt the slave valvefrom transmission side. Check forfree movement of the plunger pinprotruding from the case under theslave valve. The pin should extractwhen the transmission is shifted intogear and retract when shifted intoneutral.

    Actuating plunger pin does not movefreely.

    1. Remove actuating plunger pin andcheck for damage.

    2. Check for missing or broken spring.

    Actuating plunger pin moves freely. Repair or replace slave valve andcheck for proper range operation.

    Table 5 No or Slow Range Shift into Low

    Procedure Result What to do next

  • Air System Troubleshooting

    42

    Step R If air system has been tested andfound to operate satisfactory, theauxiliary section must be removed toinspect for mechanical problem. Re-move auxiliary section and inspectfor:•Binding of range yoke bar or piston•Damaged or defective range yoke•Damaged or defective range syn-chronizer•Cracked c/s weld resulting in gearturning on shaft•Damaged or defective range slidingclutch•Auxiliary section gearing out oftime.

    Table 5 No or Slow Range Shift into Low

    Procedure Result What to do next

  • Air System Troubleshooting

    43

    Air System Troubleshooting

    Procedure 6: Symptom - No or Slow Range Shift into HighNormal Operation:When the range selector on the shift knob is moved down to select low range, air pressure will flow through the shift knob to the‘P” port on the slave valve. The slave valve will direct air pressure through the low range 1/4” rubber supply hose to the rangecylinder to shift the range. There will be a brief burst of air at the slave valve as the high range side of the range piston exhausts.Likewise, when high range is selected, the air pressure in the “P” will be exhausted at the shift knob. This will cause the slave valveto direct air to the rear side of the range cylinder piston. The air pressure on the low range side will be exhausted at the slave valve.

    Possible Causes:

    • Incorrect air line hook up

    • Insufficient air supply to transmission

    • Plugged filter

    • Incorrect regulator pressure

    • Damaged or defective shift knob master valve

    • Damaged or defective slave valve

    • Damaged or defective range cylinder

    • Damaged or defective range yoke or yoke bar

    • Damaged or defective range synchronizer

    • Damaged or defective gearing in auxiliary section of transmission

    Table 6 No or Slow Range Shift into High

    Procedure Result What to do next

    Step A Place the shift lever in neutral. Checkfor constant air leakage at the shiftknob, slave valve, and transmissioncase breather when both low and highrange have been selected.

    Constant air leak is detected. Go to the above correspondingsymptom first. See beginning of AirSystem Troubleshooting section.

    No constant leak is detected. Go to step B.

    Step B Place shift lever in neutral. Moverange selector down to low range po-sition. At the transmission rear, dis-connect the 1/4” rubber air line fromthe range cylinder high range supplyport. Check for air flow from the cylin-der high range port.

    Air flows from the high range port. Remove range cylinder cover and re-pair leaking range piston or pistonseal. After repair, check for properrange operation.

    No air flow from high range port. Go to step C.

    Step C Check for air flow from the discon-nected air line.

    Air flows from disconnected air line. Go to step F.

    No air flows from disconnected line. Go to step D.

  • Air System Troubleshooting

    44

    Step D Install a 100 PSI air gauge in the dis-connected air line end. With the shiftlever in neutral, move the range selec-tor up to select high range. Observethe gauge.

    The gauge reads 0 PSI. Go to step F.

    The gauge reads pressure but is low-er than 58 PSI or higher than 63 PSI.

    Replace the filter/regulator and checkfor proper range operation.

    The gauge reads between 58-63 PSI. Go to Step E.

    Step E Confirm that a shift lever is still inneutral. Have an assistant move therange selector up and down betweenlow and high range. Does the pres-sure measured at the gauge respondrapidly when going from low to highto low.

    Pressure rapidly changes between58-63 PSI and O at the gauge.

    Air system appears to be operatingsatisfactory. Go to Step R.

    Pressure does not respond rapidly atgauge.

    1. Check for a plugged or dirty filter inthe filter/regulator assembly.

    2. Check for a pinched or obstructed1/4" rubber air line between the filter/regulator and slave valve.

    3. Check for a pinched or obstructed1/4" rubber air line between the slavevalve and the test gauge.

    4. If all are satisfactory, Go to Step F.

    Step F Place shift lever in neutral. At the shiftknob, move the range selector up toselect high range. At the slave valve,remove the air line from the "P" port(should be black line). Check for airflow from the disconnected line.

    Air flows from the disconnected line. 1. Confirm proper air line hook-up atthe shift knob.

    2. If correct hook-up, replace the shiftknob.

    No air flow from the disconnectedline.

    Go to Step G.

    Step G Check for air coming out of the slavevalve "P" port.

    Air flows from this port. Replace the slave valve.

    No air flow from this port. Continue to Step H.

    Table 6 No or Slow Range Shift into High

    Procedure Result What to do next

  • Air System Troubleshooting

    45

    Air System Troubleshooting

    Step H Place the shift lever in neutral. Installa 100 PSI pressure gauge in line withthe "P" line end. Move the range selec-tion lever back and forth from low tohigh range. The gauge should showrapid pressure change.

    The gauge responds slowly. 1. Check for a restricted line betweenthe shift knob and slave valve.

    2. Check for a restricted exhaust porton the shift knob.

    3. Check for a plugged or dirty filter inthe filter/regulator assembly.

    4. Check for a pinched or obstructed1/4" rubber air line between the filter/regulator and slave valve.

    5. Check for a pinched or obstructedair line between the slave valve andthe "S" port on the shift knob.

    6. If all are good, replace the shiftknob.

    The gauge rapidly moves between58-63 PSI and 0 PSI.

    Go to Step I.

    Step I If possible, leave air lines attached toslave valve. Unbolt the slave valvefrom the transmission side. Check forfree movement of the plunger pin pro-truding from the case under the slavevalve. The pin should extract when thetransmission is shifted into gear andretract when shifted into neutral.NOTE: If desired, the slave valve canbe actuated and tested while unboltedfrom the transmission case. The airlines, of course, must remain at-tached.

    Actuating plunger pin does not movefreely.

    1. Remove actuating plunger pin andcheck for damage.

    2. Check for missing or brokenspring.

    Actuating plunger pin moves freely. Repair or replace slave valve andcheck for proper range operation.

    Table 6 No or Slow Range Shift into High

    Procedure Result What to do next

  • Air System Troubleshooting

    46

    Step R If air system has been tested andfound to operate satisfactory, theauxiliary section must be removed toinspect for mechanical problem. Re-move auxiliary section and inspectfor:•Binding of range yoke bar or piston•Damaged or defective range yoke•Damaged or defective range syn-chronizer•Cracked c/s weld resulting in gearturning on shaft•Damaged or defective range slidingclutch•Auxiliary section gearing out of time.

    Table 6 No or Slow Range Shift into High

    Procedure Result What to do next

  • Air System Troubleshooting

    47

    Air System Troubleshooting

    Procedure 7: Symptom - No or Slow Shift into Deep ReductionNormal Operation:When the deep reduction button is moved forward to select deep reduction, air pressure is supplied through the “SP” air line tothe insert valve signal port. This air pressure causes the insert valve to exhaust the air pressure on the rear of the deep reductionpiston and the piston moves rearward. A burst of air occurs at the deep reduction cylinder exhaust port as this air is exhaustedfrom the piston back side. A burst of air also occurs at the shift knob when the deep reduction button is moved rearward. This isthe signal air being exhausted out of the “SP” line.

    Possible causes:

    • Incorrect air line hook up, Plugged filter.

    • Incorrect regulator pressure. Insufficient air supply to transmission.

    • Damaged or defective shift knob master valve.

    • Damaged or defective deep reduction insert valve.

    • Damaged or defective deep reduction piston or cylinder.

    • Damaged or defective deep reduction yoke bar or yoke.

    • Damaged or defective deep reduction sliding clutch or gearing.

    Note: Before completing the following troubleshooting procedure, move the deep reduction button both rearward and forward ancheck for constant exhaust air at either the shift knob or deep reduction cylinder exhaust port. If a constant leak is noticed,go to that troubleshooting procedure first. In addition, confirm that the low and high range shifts are occurring properly. Ifnot, go to the appropriate range shift troubleshooting procedure before completing the following procedure.

    Table 7 No or Slow Shift into Deep Reduction

    Procedure Result What to do next

    Step A Move range selector down to selectlow range. Move the deep reductionbutton rearward. At the deep reduc-tion cylinder on the transmissionback, remove the small air line whichprovides the signal to the insert valve(SP line). Make sure this line was con-nected to the proper port location onthe cylinder cover. Check for air flowfrom the line.

    Air flows from the disconnected line. Go to Step K.

    No air flow from disconnected line. Go to Step B.

    Step B Connect a 100 PSI pressure gauge tothe disconnected signal port line.Move the deep reduction button for-ward. Read the pressure on the gauge.

    Gauge reads 0 PSI. Go to Step F.

    Gauge reads pressure, but is lower than58 PSI or higher than 63 PSI.

    Replace filter / regulator assembly.

    Gauge reads between 58 PSI and 63PSI.

    Go to Step C.

  • Air System Troubleshooting

    48

    Step C Have an assistant move the deep re-duction button forward and rearward.Observe the pressure gauge.

    Pressure rapidly changes between 58-63 PSI and 0 PSI at the gauge.

    Go to Step D.

    Pressure does not respond rapidly atgauge.

    Go to Step F.

    Step D Remove the insert valve. NOTE: Afterthe insert valve plug has been re-moved, cover the opening with a shoprag and apply shop air to the signalline port to blow the insert valve out ofit’s bore. Catch the valve with the shoprag. If the vehicle air pressure is stillpresent, constant air flow should beblowing out of the insert valve bore.Inspect the insert valve for contamina-tion or damage. Make sure the smallpiston inside the valve can freely move1/32”.

    Insert valve is contaminated, sticking,or damaged.

    Replace insert valve, reconnect airline, and check if deep reductionshifts normally.

    Insert valve is clean and small internalpiston moves freely.

    Go to step E.

    Step E Remove the deep reduction cylindercover and deep reduction piston. In-spect piston and bore for contamina-tion or damage.

    Deep reduction cylinder bore or pistonis contaminated or damaged.

    Repair as necessary, replace insertvalve and air line. Check if deep re-duction shifts normally

    Deep reduction cylinder bore or pistonis in good condition.

    1. Remove deep reduction cylinderassembly. Inspect for contamina-tion or damage causing deep reduc-tion yoke bar to bind in cylinder.Repair as necessary.

    2. Remove auxiliary section and in-spect deep reduction yoke, slidingclutch, and gearing for damagewhich would prevent deep reduc-tion shift. Repair as necessary.

    Table 7 No or Slow Shift into Deep Reduction

    Procedure Result What to do next

  • Air System Troubleshooting

    49

    Air System Troubleshooting

    Step F At the shift knob, remove the twoscrews attaching the lower cover, andslide the lower cover down to accessthe fittings. Confirm that the air linesare connected to the proper ports.Make sure the shift lever is in neutral.Move the range selector down to se-lect low range, and move the deep re-duction button rearward. Disconnectthe air line connected to the “SP” port.Check for air flow from the “SP” port.

    Air flows from “SP” port. Replace shift knob.

    No air flow from “SP” port. Go to Step G.

    Step G Move deep reduction button forward.Check for air flow from “SP” port.

    Air flows from “SP” port. 1. Check for proper air line connec-tion from “SP” port on shift knob to“SP port on deep reduction cylin-der.

    2. Check for obstruction in “SP” airline or fittings.

    3. If clear, reconnect the air line atthe shift knob, go to step A.

    No air flow from “SP” port. Go to step H.

    Step H Disconnect air line H/L port on shiftknob. Check for air flow from the dis-connected line.

    Air flows from disconnected line. Replace shift knob.

    No air flow from disconnectedline.

    1. Check to make sure that the shiftlever is in neutral, the range selec-tor is down in low range and the “H/L” line is properly connected to thelow range hose at the slave valve.

    2. If no air pressure is available onlow range hose, perform low rangeshift troubleshooting procedure tocorrect this problem.

    Table 7 No or Slow Shift into Deep Reduction

    Procedure Result What to do next

  • Air System Troubleshooting

    50

    Procedure 8: Symptom - Range Shifts with Shift Lever in GearNormal Operation:Range shift should only occur when the shift lever is in neutral. The range selector can be moved up or down while the shift leveris in a gear position, but the shift will not occur until the shift lever is moved to neutral.

    Possible Causes:

    • Worn or missing actuating pin or air valve shaft.

    • Worn shift rail

    Procedure:If the range has been confirmed to shift with the shift lever in gear, unbolt the slave valve from the side of the transmission. Con-firm that the actuating pin is present and that it is the proper P/N for the corresponding slave valve. If correct, remove the shiftbar housing assembly and check for a worn or damaged air valve shaft or worn shift rails. Replace necessary parts.

  • Air System Troubleshooting

    51

    Air System Troubleshooting

    FR-1X210 Troubleshooting

    The symptoms listed below are covered on the following pages. Before beginning any of those troubleshooting procedures, placethe transmission in neutral and move the range selection lever from low to high. Listen for any constant air leak from the shiftknob, air module base (exhaust), or transmission breather. If a constant leak is heard, go to that particular leak troubleshootingprocedure first. If you do not see the symptom you need to correct, refer to the General Troubleshooting chart at the beginning ofthis section.

    Symptom

    • Air leak from Air Module Base (Exhaust leak)

    • No or Slow Range Shift into High (Shift into low range is good)

    • No or Slow Range Shift into Low (Shift into high range is good)

    • Constant Air Leak from Shift Knob

    • Range Shifts While Transmission is in Gear

    • Air Leak from Transmission Breather or Transmission Case is Pressurized

    Note: Use the air system troubleshooting procedures for part replacement only if the symptom can be duplicated. If the problemis intermittent, parts that are not defective could be replaced.

    Note: During all testing, the vehicle air pressure must be greater than 90 PSI (620 kPa). If during testing the pressure falls below90 PSI (620 kPa), make sure the transmission is in neutral, start the engine and let the pressure build to governor cutoff.After the pressure reaches the governor cutoff, continue testing. The pressure is critical if the vehicle is equipped with a Pres-sure Protection Valve that would shut off the air supply to certain air circuits if the system pressure dropped below a presetlevel.

    Note: A 0-150 PSI (0-1034 kPa) air gauge with a 1/16" male pipe thread fitting attachment is required for some of the test proce-dures.

    Note: Regulated air pressure is 75 to 85 PSI (517-586 kPa).

    WARNING: Prior to removing the air module, exhaust the air from it. Failure to exhaust the air module may result inpersonal injury or damage to parts from the sudden release of air.

    WARNING: Use care when removing the test port pipe plugs. If air pressure is present on the plug, it can become aprojectile during removal. When removing the “L” plug or “H” plug, pressure can be shut off by selecting the oppositerange mode. If removing the “F” plug, exhaust the air to the module inlet.

  • Air System Troubleshooting

    52

    Air System Nomenclature

    Figures 4-1 through 4-3 below show the air module, shift knob, and range alignment lock cover (earlier models) with their com-ponents labeled. These are the primary components used during troubleshooting. If necessary, refer to these figures while trou-bleshooting the air system.

  • Air System Troubleshooting

    53

    Air System Troubleshooting

    Figure 4-4 below shows how to isolate the air module. If necessary, refer to this figure when isolating the air module.

    The table below shows which air lines connect to which ports on the shift knob and air module. If necessary, refer to this tablewhen connecting the air lines.

    Figure 4-4 Air Module Isolation

    Port on Knob Port on Air Module Air Line Color (Typical)

    S S Red

    P P Black

  • Air System Troubleshooting

    54

    Air System Symptom - Air Leak from Module Base (Exhaust)

    Short bursts of air leakage from the module base (exhaust) are normal as the range system is shifted. The module base is definedas both the interface of the module cover and module base and the extreme underside of the module. Leakage is a problem whenit is audible and constant. Air leakage from the module base may result from either a defective air module or a defective rangepiston. The following procedure will identify the defective component.

    Test Procedure:1. Check for air leakage from the module base (exhaust) in each of the four following conditions. (Make sure the range is shiftedwhen the shift lever is in neutral.)

    a. Range selection lever in Low and shift lever in neutral.

    b. Range selection lever in Low and shift lever in gear.

    c. Range selection lever in High and shift lever in neutral.

    d. Range selection lever in High and shift lever in gear.

    Record the findings (constant leak or no leak) in the following table.

    2. If the information you recorded at step 1 matches one of the following tables, replace the air module. If your table does notmatch either of the tables, it will be necessary to isolate and test the air module separately, continue to step 3.

    WARNING: Failure to exhaust the air pressure may cause personal injury or damage to parts.

    3. Exhaust the air pressure from the air module. To do so, the vehicle’s air tanks may need to be exhausted.

    4. Leaving all air lines connected to the module, remove the four capscrews attaching the air module to the shift bar housing. Liftthe air module and tilt it to gain access to the two air holes at the underside on the rear capscrew location. Do not damage or losethe two o-rings used to seal the holes.

    5. Block off the air ports on the underside of the module. Use a piece of gasket material or rubber material to seal the bottom ofthe module as shown in Figure 4-1 under “Air System Nomenclature”.

    6. Repressurize the air module with an inlet supply pressure of over 90 PSI (620 kPa). To repressurize the air module, the vehiclemay need to be started and air pressure allowed to build up.

    7. Check for air leakage in both high and low range. If air continues to leak constantly from the exhaust, the air module is defective.If air does not leak, a range cylinder piston or piston seal failure has occurred. Remove the shift bar housing to gain access to therange shift cylinder.

    Range Selector in LOW Range Selector in HIGH

    Lever in Neutral

    Lever in Gear

    Range Selector in LOW Range Selector in HIGH

    Lever in Neutral No Leak Constant Leak

    Lever in Gear No Leak Constant Leak

    Range Selector in LOW Range Selector in HIGH

    Lever in Neutral Constant Leak Constant Leak

    Lever in Gear Constant Leak Constant Leak

  • Air System Troubleshooting

    55

    Air System Troubleshooting

    Air System Symptom - No or Slow Range Shift into High (Shift into Low Range is Good)

    This transmission contains a SynchroSaver feature to protect the high range synchronizer. When high range is selected and a frontsection gear is engaged, air pressure is supplied to both sides of the range piston, which reduces synchronizer force. Therefore,if the driver engages a front section gear before the high range synchronizer engages, the high range synchronizer will remain inneutral. When a front section gear engages before the synchronizer shift completes, the driver must shift the lever back to neutralto allow the high range synchronizer to complete its shift. Once the range shift is complete, the driver can complete the front sec-tion shift.

    If the high range synchronizer hangs up or is slow to synchronize, the front section may engage first. The driver complaint will bethat the transmission “neutralizes” on a shift to high range. If this condition occurs, perform the following test of the air systemto eliminate the air system as the source of the problem. If the air system performs properly, then the problem is internal to thetransmission range synchronizer system.

    Note: The driver must preselect all range shifts.

    Note: If a capscrew or stud is installed too far into the right side (air module side) rear support hole, the fastener can extend toofar into the transmission. The fastener may contact the range yoke and bind the range synchronizer assembly during therange shift.

    Test Procedure1. Check the shift knob operation.

    On the shift knob, remove the screws holding the plastic skirt. Slide the skirt down and out of the way. Move the range selectionlever up into high range. Disconnect the black line connected to the “P” port on the knob.

    2. Test the regulator pressure. (Regulator pressure should be between 75 and 85 PSI (517-586 kPa).)

    Reconnect the “P” line at the shift knob. Locate the two small pipe plugs on the rear of the air module. One is labeled “H" and theother “L”. (See Figure 4-1 “Air System Nomenclature”). Install a 0-150 PSI (0-1034 kPa) air gauge in the port marked “H.”

    Note: Prior to removing the pipe plug, turn off the air flow by flipping the range selector down into the low range position. Thetransmission must be in neutral.

    Move the range selector up to the high range position and record the pressure on the gauge. Match the pressure to one of thoseon the chart on the next page, and follow the corresponding instructions.

    Question Result What to do next

    Does air come out of the “P” port on theknob?

    Yes Repair or replace the knob.

    No Reconnect the air line to the knob, and con-tinue to the next step.

    Question Result What to do Next

    What is the air pressure atthe “H” port?

    75-85 PSI (517-586 kPa)(to specification)

    Continue to the next step.

  • Air System Troubleshooting

    56

    3. Check the spool valve function.

    With the shift lever in neutral, move the range selector from low to high several times. Answer the question on the chart below,and follow the instructions corresponding to the result.

    4. Isolate and test the air module. Refer to Figure 4-1 “Air System Nomenclature” to see an example of an isolated air module.

    WARNING: Failure to exhaust