Page 1 of 8 © 2018 CommScope, Inc. All Rights Reserved Contents Installation Instructions FST-R FLEXIBLE SERVICE TERMINAL 860646295 Rev. A TC-1405-IP Rev B, November 2018 www.commscope.com 1. About this Installation Instruction This installation instruction manual describes the installation of the FST-R terminal with full size hardened adapter and the DLX® adapters. The instructions will explain how to handle the terminal and factory integrated adapter drop ports, how to mount the terminal (hand hole and pole), how to connect and maintain the different adapter types (full size hardened and DLX) and provide guidelines on how to splice the feeder cable. 2. General product information The FST-R is a compact sealed terminal with hardened connectivity for reliable plug-n-play distribution to customer premises. Featuring pre-connectorized hardened full size or DLX adapter drops, and a round loose tube feeder cable (dia5,5mm) to splice. CommScope’s FST-R enables FTTH deployment in brown field and green field applications. Primarily designed for hand hole applications, the terminal provides fast, easy network connections in space-constrained environments. The FST-R terminal is available with 2, 4, 6, 8 and 12 fibre drops. 1. About this Installation Instruction ....................................... 1 2. General product information ................................................ 1 3. Warnings and caution ............................................................ 2 4. Required Tools ........................................................................ 2 5. Using Hardened Connectors and Adapters ......................... 2 6. Mounting Installation ............................................................ 3 7. Splicing .................................................................................... 4 8. Installing Drop cable .............................................................. 4 9. Maintenance of FST-R Terminals .......................................... 5 10. Trade-marks ............................................................................ 8 11. Contact information ............................................................... 8

Upload: others

Post on 09-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FST-R FLEXIBLE SERVICE TERMINAL · 2019. 12. 30. · Featuring pre-connectorized hardened full size or DLX adapter drops, and a round loose tube feeder cable (dia5,5mm) to splice

Page 1 of 8© 2018 CommScope, Inc. All Rights Reserved

Contents

Installation Instructions

FST-R FLEXIBLE SERVICE TERMINAL

860646295Rev. A

TC-1405-IPRev B, November 2018www.commscope.com

1. About this Installation InstructionThis installation instruction manual describes the installation of the FST-R terminal with full size hardened adapter and the DLX® adapters. The instructions will explain how to handle the terminal and factory integrated adapter drop ports, how to mount the terminal (hand hole and pole), how to connect and maintain the different adapter types (full size hardened and DLX) and provide guidelines on how to splice the feeder cable.

2. General product informationThe FST-R is a compact sealed terminal with hardened connectivity for reliable plug-n-play distribution to customer premises. Featuring pre-connectorized hardened full size or DLX adapter drops, and a round loose tube feeder cable (dia5,5mm) to splice. CommScope’s FST-R enables FTTH deployment in brown field and green field applications. Primarily designed for hand hole applications, the terminal provides fast, easy network connections in space-constrained environments. The FST-R terminal is available with 2, 4, 6, 8 and 12 fibre drops.

1. About this Installation Instruction ....................................... 12. General product information ................................................ 13. Warnings and caution ............................................................ 24. Required Tools ........................................................................ 25. Using Hardened Connectors and Adapters ......................... 26. Mounting Installation ............................................................ 3

7. Splicing .................................................................................... 48. Installing Drop cable .............................................................. 49. Maintenance of FST-R Terminals .......................................... 510. Trade-marks ............................................................................ 811. Contact information ............................................................... 8

Page 2: FST-R FLEXIBLE SERVICE TERMINAL · 2019. 12. 30. · Featuring pre-connectorized hardened full size or DLX adapter drops, and a round loose tube feeder cable (dia5,5mm) to splice

Page 2 of 8© 2018 CommScope, Inc. All Rights Reserved

3. Warnings and caution

Before installing and using FST-R, the user should fully understand the warnings and notes explained in this section.

Warning - Danger: Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the ends of the optical connectors or adapters or exposure to laser radiation may result. Use an optical power meter to verify if an optical signal is present. Do not assume the laser power is turned off or that the fiber is disconnected at the other end. The dust cap MUST be immediately placed over any radiating optical connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the connector.

Do not disassemble the product

The user should not disassemble the product. If the user thinks a repair is necessary, contact the CommScope Technical Support Team.

Installation site condition

For safe and stable use, the product should be installed in a site satisfying the following conditions:

3.1. Avoid locations where temperature is too high or low. FST-R normally operates in an environment with the following conditions: Operating temperature: -20ºC ~ 65ºC

3.2. Keep the product surroundings clean and dust-free both during and after installation.

4. Required Tools • Standard tools to mount the FST-R, and cable preparation tools for splicing fibers. • 216 key tool

5. Using Hardened Connectors and Adapters5.1. Hardened connectors and adapters provide sealed environmental protection for the subscriber drop cable connector and the SC adapter mounted within the FST-R optical port. The following sections provide a description of the connector and adapter components and provide instructions for connecting or disconnecting the drop cable to/from the optical ports.

5.2. The basic components of the drop cable connector are shown in the pictures below. The dust cap threads onto the connector coupling nut. A pair of O-rings on the connector body provide a tight seal when the dust cap is in place.

Do not exceed a pulling force of 45N.

DUST CAPO-RINGS

COUPLING NUTCONNECTOR

BODY

Full size hardened connector

DUST CAP

O-RING

COUPLING NUTCONNECTOR

BODY

DLX-Connector

Page 3: FST-R FLEXIBLE SERVICE TERMINAL · 2019. 12. 30. · Featuring pre-connectorized hardened full size or DLX adapter drops, and a round loose tube feeder cable (dia5,5mm) to splice

Page 3 of 8© 2018 CommScope, Inc. All Rights Reserved

6. Mounting Installation6.1. Product Dimension (mm):

6.2. Installing FST-R in Hand Hole / Pit / wall / pole

6.2.1. FST-R can be fixed to the side of a hand hole/pit/wall using self-tapping screw (not included in kit).

6.2.2. Ensure FST-R is located in the pit with feeder situated below the customer ports to allow easy installer access.

Page 4: FST-R FLEXIBLE SERVICE TERMINAL · 2019. 12. 30. · Featuring pre-connectorized hardened full size or DLX adapter drops, and a round loose tube feeder cable (dia5,5mm) to splice

Page 4 of 8© 2018 CommScope, Inc. All Rights Reserved

6.2.3. FST-R can be fixed on a pole with a strap (not included in the kit). Mount the FST-R as shown on picture using a strap with a width of max. 12 mm.

7. Splicing7.1. Splicing feeder cable to FST-R

Remove the cable jacket using the correct tools, and “RIP-cord” in the cable and handle the cable per standard local practice in the previous network element (ex. enclosure, terminal or hub).Cable OD= 5.5 mmLoose tube OD= 2.5 mm

8. Installing Drop cableEnsure you remove the dust caps. Use the 216B key tool (accessory) to unscrew the dust cap from the optical port, inspect and clean them if necessary. (see section 9)

Page 5: FST-R FLEXIBLE SERVICE TERMINAL · 2019. 12. 30. · Featuring pre-connectorized hardened full size or DLX adapter drops, and a round loose tube feeder cable (dia5,5mm) to splice

Page 5 of 8© 2018 CommScope, Inc. All Rights Reserved

8.1. DLX connector8.1.1. Align the DLX-connectors as shown in Figure below. The protrusions on the drop cable connector should line up with the arrow on the FST-R adapter. Insert the drop cable connector into the FST-R adapter until it slides freely into place and latches. Thread the drop cable connector coupling nut into the optical port and tighten coupling nut until fi nger tight.

8.1.2. Thread the optical port dust cap into the drop cable dust cap as shown below and then tighten both dust caps fi nger tight. This ensures that both dust caps will stay clean when not in use.

8.2. Full size hardened-connector8.2.1. Align the Full size hardened-connectors as shown in Figure below. The pointer on the drop cable connector should line up with the notch on the FST-R adapter. Insert the drop cable connector into the optical port and tighten coupling nut until fi nger tight.

8.2.2. Thread the optical port dust cap into the drop cable dust cap as shown below and then tighten both dust caps fi nger tight. This ensures that both dust caps will stay clean when not in use.

COUPLINGNUT

NOTE: ORIENT CONNECTORSO ARROW IS ALIGNEDWITH PROTRUSIONS.

ARROW

PROTRUSIONS

OPTICAL PORTDUST CAP DROP CABLE

DUST CAP

ORIENT CONNECTORSO ARROW IS ALIGNED

WITH NOTCH

COUPLINGNUT

DROP CABLEDUST CAP

OPTICAL PORTDUST CAP

Page 6: FST-R FLEXIBLE SERVICE TERMINAL · 2019. 12. 30. · Featuring pre-connectorized hardened full size or DLX adapter drops, and a round loose tube feeder cable (dia5,5mm) to splice

Page 6 of 8© 2018 CommScope, Inc. All Rights Reserved

9. Maintenance of FST-R TerminalsMaintenance for the FST-R terminal is limited to cleaning the hardened adapters as needed to maintain optimal performance.

9.1. DLX Cable Connector and adapter Cleaning ProcedureClean both the optical port adapter and the drop cable connector (requires accessory kit FHD-ACC-CLNKIT1) as specified in ADCP-96-163.

9.1.1. DLX connector cleaning

9.1.1.1. Examine the end of the drop cable connector, note the position of the protrusions on the connector.

9.1.1.2. Locate the cleaning tape cassette that is provided with the cleaning kit.

9.1.1.3. Open the tape shutter by squeezing the lever on the underside of the cassette and then keep the shutter open by continuing to squeeze the lever.

9.1.1.4. Hold connector facing you with the protrusions perpendicular to the length of the cleaning cassette, tilt the connector to the right (no more than 8-degrees) this places the connector in the correct position for cleaning.

Note: The drop cable connector uses angled SC type connectors. Make sure the connector end-face is point-ing in the correct direction before starting the cleaning motion.

9.1.1.5. With light pressure, slide the connector end-face once across the tape in the direction shown using a smooth linear motion. Do not press too hard and do not repeat the cleaning motion with the same tape.

9.1.1.6. Release the lever on the underside of the cassette to close the tape shutter.

9.1.1.7. Repeat Step 9.1.1.3 through Step 9.1.1.6 until the connector has been cleaned three times.

9.1.2. DLX adapter cleaning

9.1.2.1. Locate the dry swabs that are provided with the connector/adapter cleaning kit.

9.1.2.2. Insert a dry swab into the adapter as shown on picture below.

Note: Do not apply alcohol to the swab or the adapter.

9.1.2.3. While applying light pressure against the connector end-face, rotate the dry swab 360º three times.

9.1.2.4. Dispose of the dry swab after use.

9.1.2.5. When connector end-face and adapter are clean, install the drop cable connector into the optical port.

CASSETTECLEANING

TAPEDIRECTION

OF CONNECTORMOTION

ANGLED CONNECTORDETAIL DRAWING

PROTRUSIONS

PROTRUSIONS

Cleaning Tools

Page 7: FST-R FLEXIBLE SERVICE TERMINAL · 2019. 12. 30. · Featuring pre-connectorized hardened full size or DLX adapter drops, and a round loose tube feeder cable (dia5,5mm) to splice

Page 7 of 8© 2018 CommScope, Inc. All Rights Reserved

9.2. Full size hardened connector and adapter Cleaning ProcedureClean both the optical port adapter and the drop cable connector (requires accessory kit FHD-ACC-CLNKIT1) as specified in ADCP-96-067.

9.2.1. Full size hardened connector cleaning

9.2.1.1. Examine the end of the drop cable connector and determine which is the high side which is the low side of the connector end-face.

9.2.1.2. Locate the cleaning tape cassette that is provided with the cleaning kit.

9.2.1.3. Open the tape shutter by squeezing the lever on the underside of the cassette and then keep the shutter open by continuing to squeeze the lever.

9.2.1.4. Hold the end-face of the drop cable connector per- pendicular to the cleaning tape and with the high side of the connector pointing in the direction of cleaning.

9.2.1.5. With light pressure, slide the connector end-face once across the tape in the direction shown using a smooth linear motion. Do not press too hard and do not repeat the cleaning motion with the same tape.

9.2.1.6. Release the lever on the underside of the cassette to close the tape shutter.

9.2.1.7. Repeat Step 9.2.1.3 through Step 9.2.1.6 until the connector has been cleaned three times.

.

9.2.2. Full size hardened adapter cleaning

9.2.2.1. Cleaning kit (FHD-ACC-CLNKIT1) is required for this procedure or use a tool as shown on picture below.

9.2.2.2. Locate the dry swabs that are provided with the connector/adapter cleaning kit.

9.2.2.3. Insert a dry swab into the adapter as shown in picture.

Note: Do not apply alcohol to the swab or the adapter.

9.2.2.4. While applying light pressure against the connector end-face, rotate the dry swab 360º three times. Dispose of the dry swab after use.

9.2.2.5. When connector end-face and adapter are clean, install the drop cable connector into the optical port.

HIGH SIDEOF END-FACE

WIPE DIRECTIONOF CLEANING

LOW SIDEOF END-FACE

ANGLED CONNECTORDETAIL DRAWING

Cleaning Tools

Page 8: FST-R FLEXIBLE SERVICE TERMINAL · 2019. 12. 30. · Featuring pre-connectorized hardened full size or DLX adapter drops, and a round loose tube feeder cable (dia5,5mm) to splice

Page 8 of 8© 2018 CommScope, Inc. All Rights Reserved

10. Trade-marksAll trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. CommScope is committed to the highest standards of business integrity and environmental sustainability, with a number of CommScope’s facilities across the globe certified in accordance with international standards, including ISO 9001, TL 9000, and ISO 14001.

Further information regarding CommScope’s commitment can be found atwww.commscope.com/About-Us/Corporate-Responsibility-and-Sustainability.

11. Contact informationVisit our website or contact your local CommScope representative for more information.

For technical assistance, customer service, or to report any missing/damaged parts, visit us at:http://www.commscope.com/SupportCenter

This product may be covered by one or more U.S. patents or their foreign equivalents. For patents, see www.cs-pat.com.