front load specifications - denton, texas€¦ · web viewexterior to be painted with one (1) coat...

29
CITY OF DENTON RFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS EXHIBIT 3 TECHNICAL SPECIFICATIONS The technical specifications shall be finalized upon the selection of the Firm. The proposal submission shall have accurately described your understanding of the objectives and scope of the requested products and services and provided an outline of your process to implement the requirements of the scope of work and/or technical specification below. It is anticipated that the scope proposal submission will include, at a minimum, the following: FRONT LOAD SPECIFICATIONS Proposers must state make and model number of the unit they are offering. Proposals submitted shall be on the latest current model of equipment meeting specifications and shall conform to the latest American National Standards Z 245.1 – 1975 safety requirements for refuse collection and compaction equipment. All containers and related equipment are to be cleaned of all weld splatter and slag, oil and excessive rust. Interior and exterior to be primed with (1) coat of High Solid Alkyd Rust inhibitive Primer, or equal. Exterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container Green 91D377-5. or equal). Recycle containers to be to be primed and painted the same with the exception of color, use Safety Blue, or equal. If Purchase Order does not specify color, color should be Emsco Green or Dark Container Green or Safety Blue or equal. All sharp edges should be ground to prevent injury, welds should be smooth with no welding wire visible, and all seams and joints must be fitted correctly.

Upload: others

Post on 26-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

EXHIBIT 3

TECHNICAL SPECIFICATIONS

The technical specifications shall be finalized upon the selection of the Firm. The proposal submission shall have accurately described your understanding of the objectives and scope of the requested products and services and provided an outline of your process to implement the requirements of the scope of work and/or technical specification below. It is anticipated that the scope proposal submission will include, at a minimum, the following:

FRONT LOAD SPECIFICATIONS

Proposers must state make and model number of the unit they are offering. Proposals submitted shall be on the latest current model of equipment meeting specifications and shall conform to the latest American National Standards Z 245.1 – 1975 safety requirements for refuse collection and compaction equipment.

All containers and related equipment are to be cleaned of all weld splatter and slag, oil and excessive rust. Interior and exterior to be primed with (1) coat of High Solid Alkyd Rust inhibitive Primer, or equal. Exterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container Green 91D377-5. or equal). Recycle containers to be to be primed and painted the same with the exception of color, use Safety Blue, or equal. If Purchase Order does not specify color, color should be Emsco Green or Dark Container Green or Safety Blue or equal.

All sharp edges should be ground to prevent injury, welds should be smooth with no welding wire visible, and all seams and joints must be fitted correctly.

All containers shall have a metal plate attached to the item listing model #, serial #, manufacturer and date of manufacturing.

All equipment shall be marked for safety in operation according to American National Standard Specification and other regulations as applicable.

All items must be new and unused.

Technical Specifications for Proposal Item 1A – 4:

Front Load Containers Designed for McNeilus Lift Systems

1. Blunderbuss: 7 GA

Page 2: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

2. Metal plate: listing model #, serial #, manufacturer & date of manufacturing3. Upper sleeve gusset: 3/16”4. Lower sleeve gusset: 3/16”5. Drain: 1¼ weld flange6. PVC drain plug7. Lift sleeve: 3/16”8. Hinge pin 5/8” HR RD, flat washer, 1/8” x 1” cotter pin 9. Hinge bracket: inside & outside: 7 GA10. Lids .250 UV stabilized high molecular polyethylene made of new, non-

recycled material11. Container numbers to be painted left front top corner of container, no more

than 2” from top edge and no more than 2” from left edge, using 2-2” letter and 4-2” numbers. Numbers to be consecutive, FL3-0001, FL3-0002 etc.

12. Bottom channel: 10 GA (floor support)13. Top framing for front, rear & side: 11 GA14. Buff plate: 7 GA x 2” x 19” long15. Front & rear sheet: 12 GA; bottom sheet: 10 GA16. Floor support: 2, 3, 4 yd; 2 full length structural channel, skids with end

caps17. Floor support: 6 and 8 yd; 3 full length structural channel, skids with end

caps18. Door sheet: 16 GA, Door handle 3/16” x 1 F.L., Door track channel 3/16”19. 6 and 8 cubic yard to have right and left free slide metal doors 30” x 30”20. Horizontal corrugations across front sheet of 6 and 8 yd21. Dimensions (approximate): for further details see pages 12 – 1822. All deliveries shall be scheduled (Date & Time) unless otherwise requested.

Size W D H

3 cu. yd. 72 45 494 cu. yd. 72 57 496 cu. yd. Slant 72 74 626 cu. yd. Lo profile 72 69 606 cu. yd. Hi profile 72 57 738 cu. yd. Lo Profile 72 74 778 cu. yd. Hi profile 72 69 818 cu. yd. Slant 72 76 72 rear/50 front

Containers to be welded solid on inside and be waterproofed up to the first opening (lid or side door).

23. Refuse container numbers to be painted on left front top corner of container, no more than 2” from top edge and no more than 2” from left edge, using 2-2” letters and 4-2” numbers. Numbers to be consecutive, FL3-0001, FL3-0002 etc.

Page 3: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

24. Recycling container numbers are to be painted on right front top corner of container 3-2” letters and 3-2” numbers. Numbers to be consecutive RFS8-101, RFS8-102 etc.

FL3-0001 to be installed on 3 yd Front Load. FL3-0001, FL3-0002, FL3-0003 etc.FL4-0001 to be installed on 4 yd Front Load. FL4-0001, FL4-0002, FL4-0003 etc.FS6-0001 to be installed on 6 yd Slant. FS6-0001, FS6-0002, FS6-0003 etc.FL6-0001 to be installed on 6 yd Lo Profile. FL6-0001, FL6-0002, FL6-0003 etc.FH6-0001 to be installed on 6 yd Hi Profile. FH6-0001, FH6-0002, FH6-0003 etc.FS8-0001 to be installed on 8 yd Slant FS8-0001, FS8-0002, FS8-0003 etc.FL8-0001 to be installed on 8 yd Lo Profile FL8-0001, FL8-0002, FL8-0003 etc.FH8-0001 to be installed on 8 yd Hi Profile FH8-0001, FH8-0002, FH8-0003 etc.RFS6-0001 to be installed on 6 yd Slant.RFS6-0001, RFS6-0002, RFS6-0003 etc.RFS8-0001 to be installed on 8 yd Slant RFS8-0001, RFS8-0002, RFS8-0003 etc

Page 4: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

1 BLUNDERBUSS: 7 GA

2 METAL PLATE: LISTING MODEL #, SERIAL #, MANUFACTURER & DATE OF MANUFACTURING

3 UPPER SLEEVE GUSSET: 3/16”

4 LOWER SLEEVE GUSSET: 3/16”

Page 5: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

5 DRAIN: 1¼ WELD FLANGE

6 PVC DRAIN PLUG

7 LIFT SLEEVE: 3/16”

8 HINGE PIN 5/8” HR RD, FLAT WASHER, 1/8” x 1” COTTER PIN

9 HINGE BRACKET: INSIDE & OUTSIDE: 7 GA

10 LIDS .250 UV STABILIZED HIGH MOLECULAR POLYETHYLENE

11CONTAINER NUMBERS TO BE PAINTED ON LEFT FRONT TOP CORNER OF CONTAINER 2-2” LETTER AND 4-2” NUMBERS. NUMBERS TO BE CONSECUTIVE, FL3-0001, FL3-0002 ETC.

12 BOTTOM CHANNEL: 10 GA (FLOOR SUPPORT)

13 TOP FRAMING FOR FRONT, REAR & SIDE: 11 GA

14 BUFF PLATE: 7 GA x 2” x 19” LONG

15 FRONT & REAR SHEET: 12 GA, BOTTOM SHEET: 10 GA

Page 6: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

3 YD FRONT LOAD

Page 7: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

4 YD FRONT LOAD

Page 8: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

6 YD SLANT FRONT LOAD

Page 9: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

8 YD SLANT FRONT LOAD

Page 10: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

8 YD HIGH FRONT LOAD

Page 11: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

8 YD LO PROFILE FRONT LOAD

Page 12: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

SIDE LOAD SPECIFICATIONS

Proposers must state make and model number of the unit they are offering. Proposals submitted shall be on the latest current model of equipment meeting specifications and shall conform to the latest American National Standards Z 245.1 – 1975 safety requirements for refuse collection and compaction equipment.

All containers and related equipment are to be cleaned of all weld splatter and slag, oil and excessive rust. Interior and exterior to be primed with (1) coat of High Solid Alkyd Rust inhibitive Primer, or equal. Exterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container Green 91D377-5. or equal). Recycle containers to be to be primed and painted the same with the exception of color, use Safety Blue, or equal. If Purchase Order does not specify color, color should be Emsco Green or Dark Container Green or Safety Blue or equal.

All sharp edges should be ground to prevent injury, welds should be smooth with no welding wire visible, and all seams and joints must be fitted correctly.

All containers shall have a metal plate attached to the item listing model #, serial #, manufacturer and date of manufacturing.

All equipment shall be marked for safety in operation according to American National Standard Specification and other regulations as applicable.

All items must be new and unused.

Technical Specifications for Proposal Item 2A-2B(2):

Side Load Containers Designed for EMCO Lift Systems

1. Metal plate: listing model #, serial #, manufacturer & date of manufacturing2. Lids .250 UV stabilized high molecular polyethylene made of new, non-

recycled material3. Container numbers to be painted left front top corner of container, no more

than 2” from top edge and no more than 2” from left edge, using 2-2” letter and 4-2” numbers. Numbers to be consecutive, FL3-0001, FL3-0002 etc.

4. Bottom channel: 10 GA (floor support)5. Top framing for front, rear & side: 11 GA6. Front & rear sheet: 12 GA; bottom sheet: 12 GA7. Floor support: 3 & 4 yd; 2 full length structural channel, skids with end caps8. Dimensions (approximate): for further details see pages 12 – 18

Page 13: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

9. All deliveries shall be scheduled (Date & Time) unless otherwise requested.

Size W D H

3 cu. yd. 58 38 54 ½ 4 cu. yd. 58 54 70 ½

Containers to be welded solid on inside and be waterproofed up to the first opening (lid or side door).

10. Refuse container numbers are to be painted on left front top corner of container, no more than 2” from top edge and no more than 2” from left edge, using 2-2” letters and 4-2” numbers. Numbers to be consecutive, SL3-0001, SL3-0002 etc.

11. Recycling container numbers are to be painted on left front top corner of container 3-2” letters and 3-2” numbers. Numbers to be consecutive RSL3-0001, RSL3-0002 etc.

SL3-0001 to be installed on 3 yd side load SL3-0001, SL3-0002, SL3-0003, etc.SL4-0001 to be installed on 4 yd side load SL4-0001, SL4-0002, SL4-0003, etc.RSL3-0001 to be installed on 3 yd blue side load RSL3-0001, RSL3-0002, RSL3-0003, etc.RSL4-0001 to be installed on 4 yd blue side load RSL4-0001, RSL4-0002, RSL4-0003, etc.

Page 14: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

1 12 gauge Body Panels2 12 gauge Floor3 1 ½” x 2 ½” Structural Tubing on Top Rails4 Front & Back Rails (11 gauge tubing)5 10 gauge Bottom Runner6 Hookup (Emco hooks)7 Lids ( ½” metal with 2/plastic lid)8 Container numbers to be painted on left front top corner of container. 2-2” Letter and 4-

2” numbers. Numbers to be consecutive, SL3-0001, SL3-0002, etc.

9 Metal Plate: Listing Model #, Serial #, Manufacturer & Date of Manufacturing.

Page 15: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

3 Yd. Side Load

Page 16: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

4 Yd. Side Load

Page 17: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

RECTANGULAR ROLL-OFF SPECIFICATIONS

Proposers must state make and model number of the unit they are offering. Proposals submitted shall be on the latest current model of equipment meeting specifications and shall conform to the latest American National Standards Z 245.1 – 1975 safety requirements for refuse collection and compaction equipment.

All containers and related equipment are to be cleaned of all weld splatter and slag, oil and excessive rust. Interior and exterior to be primed with (1) coat of High Solid Alkyd Rust inhibitive Primer, or equal. Exterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container Green 91D377-5. or equal). Recycle containers to be to be primed and painted the same with the exception of color, use Safety Blue, or equal. If Purchase Order does not specify color, color should be Emsco Green or Dark Container Green or Safety Blue or equal.

All sharp edges should be ground to prevent injury, welds should be smooth with no welding wire visible, and all seams and joints must be fitted correctly.

All containers shall have a metal plate attached to the item listing model #, serial #, manufacturer and date of manufacturing.

All equipment shall be marked for safety in operation according to American National Standard Specification and other regulations as applicable.

All items must be new and unused.

Technical Specifications for Proposal Item 3A-3C(3):

Rectangular Roll-Off Containers:

1. Floor : ¼”2. Walls: 10 gauge3. Crossmembers: 18”4. Wall Post Spacing 24”5. Long Sills: 6x2x1/4”6. Top Rail: 4x3x11 gauge7. Door Sheet: 12 gauge8. Head Sheet: 12 gauge9. Hook: ¼”10. Hook plate: 7/8”

Page 18: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

11. Rear Rollers: 8”x9”12. Push Plates: ½”13. Metal plate: listing model #, serial #, manufacturer & date of manufacturing14. Container numbers to be painted right front top corner of container, no more

than 2” from top edge and no more than 2” from left edge, using 2-2” letter and 4-2” numbers. Numbers to be consecutive, 030-0001, 030-0002 etc.

15. Dimensions (approximate): for further details see pages 12 – 1816. All deliveries shall be scheduled (Date & Time) unless otherwise requested.

Size W H L

15 cu. yd. 96 32 22’ 20 cu. yd. 96 41½ 22’ 30 cu. yd. 96 61 22’

Containers to be welded solid on inside.

17. Refuse container numbers to be painted on right front top corner of container, no more than 2” from top edge and no more than 2” from left edge, using 2-2” letters and 4-2” numbers. Numbers to be consecutive, 030-0001, 030-0002 etc.

015-0001 to be installed on 15 yd. open top 015-0001, 015-0002, 015-0003, etc.020-0001 to be installed on 20 yd. open top 020-0001, 020-0002, 020-0003, etc.030-0001 to be installed on 30 yd. open top 030-0001, 030-0002, 030-0003, etc.

Page 19: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

1 Floor ¼”2 Wall 10 gauge3 Crossmembers 18”4 Wall Post Spacing 24”5 Long Sills 6x2x1/4”6 Top Rail 4x3x11 gauge7 Door Sheet 12 gauge8 Head Sheet 12 gauge9 Hook 1 ¼”10 Hook Plate 7/8”11 Rear Rollers 8” x 9”12 Push Plates ½”13 Container numbers to be painted on left front top corner of container. 2-2” Letter and 4-2”

numbers. Numbers to be consecutive, SL3-0001, SL3-0002, etc.14 Metal Plate: Listing Model #, Serial #, Manufacturer & Date of Manufacturing.

Page 20: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

15 Yd. Open Top Roll Off

Page 21: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

20 Yd. Roll Off

Page 22: FRONT LOAD SPECIFICATIONS - Denton, Texas€¦ · Web viewExterior to be painted with one (1) coat of H-I-S PAINT Alkyd Industrial Enamel. Emsco Green Code #90D32 or Dark Container

CITY OF DENTONRFP 6379 FOR STEEL REFUSE COLLECTION CONTAINERS

30 Yd. Roll Off