from safety to dual safety - norwep.com · from safety to dual safety marketing & business...

20
ID: Autronca Fire and Gas Detection Solution 1 From Safety to Dual Safety Marketing & Business Development A/P Rolf Hansen General Manager ENGTEK - Tommy Tan

Upload: others

Post on 26-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID:

Autronca Fire and Gas Detection Solution

1

From Safety to Dual Safety

Marketing & Business Development A/P

– Rolf Hansen

General Manager ENGTEK

- Tommy Tan

Page 2: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID:

Autronica – the complete value chain

� Founded in 1957 in Trondheim, Norway

� Autronica handles all development and production itself for Fire detection equipment.

� We deliver complete systems and total solutions

2 2

Page 3: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID: 3

Petrochemical, Oil & Gas

Autronica O&G Branch offices

Autronica O&G Partners

Huston Busan

Dubai

London

Autronica HQ

Stavanger

More than 50 years experience

Autronica’s GLOBAL organization

ENGTEK

Page 4: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID:

Always in Front, Development History

Page 5: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID:

Overall Avoid this Situation by using Reliable Solution

Page 6: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID: 6

Flame Detectors

Gas Detectors

Smoke/Heat/Multisensors/HSSD

Call Points

Field Equipment for Fire and Gas detection

Page 7: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID: 7

Integrated FIRE & GAS detection solution

SIL 2 approval

Page 8: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID: 8

Safety Integrity Level

� Safety Integrity Level (SIL) is defined as a relative level of risk-reduction provided by a safety function., SIL is a measurement of performance required

.

Integrated Fire and Gas System SIL-2 approved

It should be noted that a SIL number applies to a complete function

Page 9: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID: 9

� In the mid nineties, Autronica Fire and Security AS was approached by oil companies operating on the Norwegian Continental Shelf (BP, Total, Shell) with an opportunity to look into the possibilities of developing a self-verification functionality for fire and gas detectors.

� The aim was to increase reliability and lower life-cycle cost for the fire and gas detection systems.

IEC 61508 SIL 2

SelfVerify® Calibrated Test Every 24 Hours

Page 10: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID: 10

SelfVerify® Calibrated Test every 24 hours

Page 11: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID: 11

LCC calculation results

ExampleExampleExampleExample DetecDetecDetecDetec----torstorstorstors

Costs in USD million, Costs in USD million, Costs in USD million, Costs in USD million, withoutwithoutwithoutwithoutselfselfselfself----verificationverificationverificationverification (test scheme II)(test scheme II)(test scheme II)(test scheme II)

Costs in USD million, Costs in USD million, Costs in USD million, Costs in USD million, withwithwithwithselfselfselfself----verificationverificationverificationverification (test scheme V)(test scheme V)(test scheme V)(test scheme V)

Primary invest-ment

Operat./ mainten-ance

TotalLCC

Primary invest-ment

Operat./mainten-ance

TotalLCC

GasGasGasGasandandandandFlameFlameFlameFlame

800 gas 5.88 7.60 13.48 6.02 1.90 7.92

400flame

3.95 3.80 7.75 4.10 0.95 5.05

Total 9.83 11.40 21.2321.2321.2321.23 10.12 2.85 12.9712.9712.9712.97

Smoke/Smoke/Smoke/Smoke/HeatHeatHeatHeat

700 4.47 6.67 11.1411.1411.1411.14 4.50 1.67 6.176.176.176.17

TotalTotalTotalTotal 1900 14.30 18.07 32.3732.3732.3732.37 14.62 4.52 19.1419.1419.1419.14

SelfVerify® Calibrated Test Every 24 Hours

Page 12: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID:

AutroSafe DYFi+

Smouldering Fire Filter• Reliable and fast alarm of slow fire

development� A Life Saver

Transient Filter• Filters out misleading phenomena

that result in unwanted alarms� Avoid false Alarms

Pollution Filter• Fault warning before unwanted

alarm or “dying” detector

� Maintain the System before getting Alarm

Save Lives and Avoid False Alarm

Page 13: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID:

Dual Safety FIRE & GAS detection solution

Page 14: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID: 14

AutroSafe Sys. & Utility Software Package

� AS Configuration Tool� Merge Tool

� Power Calculators

� Import/Export Tools

� Download Tools

� AS I/O Simulator Tool� The perfect Application

Software verification Tool

� Loop Diagnostics Tool� WAS-2000 and AS-2000

Page 15: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID:

Autronica – always a safe choice

� Designed and approved according to international standards and regulations

� EX certification

� IEC61508 SIL 2

15

NAN YANG

Page 16: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID:

Why SELECT Autronica Fire & Gas solution

Experience and References (Marked leader in Offshore)

Give Quality due to Failure Modes and Effects Analysis (FMEA)

A successful FMEA activity helps a team to identify potential failure modes based on past experience with similar products processes.

Certified Technology – SIL 2

Give Risk Reduction and Required Performance for a Reliable and High Uptime system proven to standards, IEC 61 508 SIL

Self Verify – SIL 2

Give Security and Confidence that the system is testet every day and not only every 3 month by manual testing

Special features like Dynamic Filters - DYFI+

To save lives and continue stable drilling and production by not receiving false alarms. If you have a false alarm it could be that you need to stop Drilling / Production and all personal has to be evacuated.

Page 17: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID:

Loops for Gas and Flame Detectors

Decrease Installation cost, Cabling cost and Configuration cost by using addressable detectors, same principle as Fire addressable system.

WW Network and Autronica Hub offices

To get the best System and Service support wherever the vessels or Rigs will operate.

Software and Hardware tools

Do easy Configuration/Programming and in operation Save fault finding time and maintenance

Experience and References Gas Sampling System

Autronica (Omicron) has been I business since 1993

Why SELECT Autronica Fire & Gas solution

Page 18: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID:

Making sure you’re in control

AutroMaster Integrated Safety and Emergency System (ISEMS)

� Combining the strengths of a powerful

fire detection system with functions

dedicated to make sure you are in

control in case of an emergency

� Saves time when most needed

� Full overview

� Ease of use

� Interoperability

AutroMaster, Man Machine Interface

Page 19: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID:

Gas Sampling System

For FPSO and other installation that require Gas analyzingfrom isolated room and ‘pockets’

Page 20: From Safety to Dual Safety - norwep.com · From Safety to Dual Safety Marketing & Business DevelopmentA/P – Rolf Hansen General Manager ENGTEK-Tommy Tan. ID: Autronica – the complete

ID: 20

ThankThankThankThank YouYouYouYou