*fragrance free, one-step disinfectant, sanitizer ... rooms, ambulance, blood banks, dialysis...

1
110 WIPES WIPE DIMENSIONS: 7IN. X 8IN., 2.14 lbs (970 g) ACTIVE INGREDIENT: Ethyl alcohol....... 20.0% OTHER INGREDIENTS: ........................... 80.0% TOTAL: ....................................................100.0% KEEP OUT OF REACH OF CHILDREN 2 MINUTE Disinfection * COMPATIBLE with Common Healthcare Surfaces STORAGE AND DISPOSAL: Do not contaminate water, food, or feed by storage and disposal. Product Storage: Store this product in a cool dry area, away from direct sunlight and heat to avoid deterioration. Towelette Disposal: Do not re-use towelette. Discard wipe in trash receptacle after use. Do not flush. Container Handling: Nonrefillable container. Do not reuse or refill this container. Offer for recycling, if available. If recycling is not available, discard in trash or in a sanitary landfill. PHYSICAL OR CHEMICAL HAZARDS: Combustible. Do not use or store near heat or open flame. VIRUSES †Influenza A virus (flu virus) 15 seconds †Respiratory Syncytial Virus (RSV) (a cause of the common cold) 15 seconds †Human Coronavirus, Strain 229E (a cause of the common cold) 15 seconds *†Murine norovirus 2 minutes †Human Hepatitis B virus (HBV) 20 seconds †Human Hepatitis C virus (HCV) 20 seconds †Human immunodeficiency virus Type I (HIV-1) 15 seconds †Rotavirus 30 seconds BACTERIA Streptococcus pyogenes (Strep) 60 seconds Klebsiella pneumoniae multi-drug resistant [MDR] 60 seconds Pseudomonas aeruginosa (Pseudomonas) 60 seconds 1 Methicillin-resistant staphylococcus aureus (MRSA) 80 seconds ¥Staphylococcus aureus (Staph) 2 minutes Vancomycin Resistant Enterococcus faecalis (VRE) 60 seconds ¥Escherichia coli (E. coli) 60 seconds Bordetella pertussis 60 seconds Enterobacter aerogenes 75 seconds Acinetobacter baumannii (multi-drug resistant) (MDR) 60 seconds *When use-directions for disinfection and sanitization are followed **Not recommended for use on alcohol soluble wood finishes. Test in small inconspicuous area before broad application. HEALTHCARE SURFACE DISINFECTING WIPES 9340-640-HC100 Hard, Nonporous Use Sites Hospitals, Healthcare facilities, Physician and Dental Offices, Pediatrics, Nursing Homes, Home Health Care, Nurseries, Neonatal units, Emergency rooms, Ambulance, Blood banks, Dialysis centers, Hospices, Labs, Rehabilitation, Medical research facilities, Patient care rooms & facilities, Exam rooms, Radiology, Operating rooms, Orthopedic clinics, Surgical centers, Isolation areas, Recovery rooms, Transport vehicles, Vet offices and clinics This product is approved for use on medical equipment surfaces. See label for details. DIRECTIONS FOR USE: It is a violation of Federal Law to use this product in a manner inconsistent with its labeling. This product is not to be used as a terminal sterilant/high level disinfectant on any surface or instrument that (1) is introduced directly into the human body, either into or in contact with the bloodstream or normally sterile areas of the body, or (2) contacts intact mucous membranes but which does not ordinarily penetrate the blood barrier or otherwise enter normally sterile areas of the body. This product may be used to pre-clean or decontaminate critical or semi-critical medical devices prior to sterilization or high-level disinfection. DISINFECTION DIRECTIONS TO DISINFECT HARD, NONPOROUS SURFACES: Visible soil must be removed prior to disinfecting by pre-cleaning the surface. Wipe surface until completely wet. Treated surfaces must remain wet for appropriate contact time listed below. Allow to air dry or wipe with a clean cloth or paper towel after appropriate contact time has expired. A water rinse is not required. TO DISINFECT NON-CRITICAL PRE-CLEANED INSTRUMENTS: Visible soil must be removed prior to disinfecting by pre-cleaning the surface. Wipe instruments until surfaces are completely wet. Treated surfaces must remain wet for appropriate contact time listed on this label. Allow to air dry or wipe with a clean cloth or paper towel after appropriate contact time has expired. A water rinse is not required. SANITIZATION DIRECTIONS TO SANITIZE HARD, NONPOROUS FOOD CONTACT SURFACES¥ : Visible soil must be removed prior to sanitizing by pre-cleaning the surface. Wipe surface until completely wet. Treated surfaces must remain wet for 60 seconds. Allow to air dry or wipe with a clean, cloth or paper towel after 60 second contact time has expired. A water rinse is not required. SPECIAL INSTRUCTIONS FOR CLEANING AND DECONTAMINATION AGAINST HIV-1, HBV and HCV ON SURFACES/OBJECTS SOILED WITH BLOOD OR BODY FLUIDS: This product kills HIV, HBV and HCV on pre cleaned environmental surfaces/objects previously soiled with blood/body fluids in healthcare settings or other settings in which there is an expected likelihood of soiling of inanimate surfaces/objects with blood/body fluids and in which the surfaces/objects likely to be soiled with blood/body fluids can be associated with the potential for transmission of Human Immunodeficiency Virus Type 1 (HIV 1) (associated with AIDS) [Human] Hepatitis B Virus (HBV) and [Human] Hepatitis C Virus (HCV) Personal Protection: When handling items soiled with blood or body fluids use disposable impervious gloves, gowns, masks and eye coverings. Cleaning Procedures: Blood and body fluids must be thoroughly cleaned from surfaces and objects before application of this product. Contact time: Wipe surface until completely wet and let stand for 20 seconds. Note: contact times for other micororganisms on this label may vary. Infectious Materials Disposal: Blood and other body fluids should be autoclaved and disposed of according to local regulations for infectious disposal. Medical Equipment Surfaces: Dental chairs, Dental unit instrument trays, dental curing lights, Operating tables, Examination tables, X-ray tables, Patient care equipment, MRI machines, Dialysis machines, External ultrasound transducers and probes, Chemotherapy hoods, Oxygen hoods, CAT scans, stretchers, medical carts, Blood pressure monitors, gurneys, stethoscopes, diagnostic equipment, Patient support and delivery equipment, Infant incubators, Blood glucose meters TO OPEN PACKAGE: Flip open dispensing cap and remove entire lid from canister by lifting upward. Locate wipe at center of roll, twist corner to a point and thread through small opening in lid. DO NOT PUSH FINGER THROUGH OPENING. Replace lid and pull sheet up at an angle. Remaining wipes feed automatically. When finished, snap lid cap shut to retain moisture. N O B L E A C H N O H A R S H F U M E S KILLS: MRSA 1 , HBV , HCV , HIV-1 , INFLUENZA A *FRAGRANCE FREE, ONE-STEP DISINFECTANT, SANITIZER, DEODORIZER, CLEANER Hard, Nonporous High Touch Surfaces: Bed frames, railings and matresses, Bedside tables, IV poles, wheelchairs, walkers, nurse call buttons, cabinet handles, keyboards, light switches, door knobs, ¥tables, chairs, stools, ¥counters, carts, telephones, handrails, mobile workstations, electronic screens, keyboards, handheld electronic devices, ¥childrens toys Hard, Nonporous Use Surfaces: Acrylic, chrome, finished wood**, glazed tile, fiberglass surfaces, laminate, metal, plastic, glazed porcelain, stainless steel, vinyl HEALTHCARE SURFACE DISINFECTING WIPES EPA Reg. No. 84150-1 EPA Est. No.: 84150-OH-001 (CF), 84150-OH-002 (WR), 84150-OH-003 (ST), 73027-WI-1 (MP), 50757-WI-1 (GN), 50757-WI-2 (GY) Beginning of batch code indicates EPA Est. No. Distributed by: GOJO Industries, Inc., PO Box 991, Akron, OH 44309 Ingredient information / Questions? Tel: 1-888-4-PURELL ©2018. GOJO Industries, Inc. All rights reserved. Made in U.S.A. DISINFECTS FOOD CONTACT SURFACES, NO RINSE REQUIRED THICK, DURABLE WIPE LEAVES NO DULL OR STICKY RESIDUE BROAD SPECTRUM DISINFECTANT NOT FOR USE ON SKIN NOT FOR PERSONAL CLEANING NOT FOR USE AS A BABY WIPE 84150-1_Purell Healthcare Surface Disinfecting Wipes_20190529_9_84150_.pdf

Upload: others

Post on 11-Jun-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: *FRAGRANCE FREE, ONE-STEP DISINFECTANT, SANITIZER ... rooms, Ambulance, Blood banks, Dialysis centers, ... Visible soil must be removed prior to disinfecting by pre-cleaning the surface

110 WIPESWIPE DIMENSIONS: 7IN. X 8IN., 2.14 lbs (970 g)

ACTIVE INGREDIENT: Ethyl alcohol....... 20.0%OTHER INGREDIENTS: ........................... 80.0%TOTAL: .................................................... 100.0%

KEEP OUT OF REACHOF CHILDREN

2 MINUTE Disinfection*

COMPATIBLE with Common Healthcare Surfaces

STORAGE AND DISPOSAL: Do not contaminate water, food, or feed by storage and disposal.Product Storage: Store this product in a cool dry area, away from direct sunlight and heat to avoid deterioration. Towelette Disposal: Do not re-use towelette. Discard wipe in trash receptacle after use. Do not �ush. Container Handling: Nonre�llable container. Do not reuse or re�ll this container. Offer for recycling, if available. If recycling is not available, discard in trash or in a sanitary land�ll.

PHYSICAL OR CHEMICAL HAZARDS: Combustible. Do not use or store near heat or open �ame.†VIRUSES†In�uenza A virus (�u virus) 15 seconds†Respiratory Syncytial Virus (RSV) (a cause of the common cold) 15 seconds†Human Coronavirus, Strain 229E (a cause of the common cold) 15 seconds *†Murine norovirus 2 minutes†Human Hepatitis B virus (HBV) 20 seconds†Human Hepatitis C virus (HCV) 20 seconds†Human immunode�ciency virus Type I (HIV-1) 15 seconds†Rotavirus 30 seconds

BACTERIAStreptococcus pyogenes (Strep) 60 secondsKlebsiella pneumoniae multi-drug resistant [MDR] 60 secondsPseudomonas aeruginosa (Pseudomonas) 60 seconds1Methicillin-resistant staphylococcus aureus (MRSA) 80 seconds¥Staphylococcus aureus (Staph) 2 minutes Vancomycin Resistant Enterococcus faecalis (VRE) 60 seconds¥Escherichia coli (E. coli) 60 secondsBordetella pertussis 60 secondsEnterobacter aerogenes 75 secondsAcinetobacter baumannii (multi-drug resistant) (MDR) 60 seconds

*When use-directions for disinfection and sanitization are followed**Not recommended for use on alcohol soluble wood �nishes. Test in small inconspicuous area before broad application.

HEALTHCARE

SURFACEDISINFECTING WIPES

9340-640-HC100

Hard, Nonporous Use SitesHospitals, Healthcare facilities, Physician and Dental Of�ces, Pediatrics, Nursing Homes, Home Health Care, Nurseries, Neonatal units, Emergency rooms, Ambulance, Blood banks, Dialysis centers, Hospices, Labs, Rehabilitation, Medical research facilities, Patient care rooms & facilities, Exam rooms, Radiology, Operating rooms, Orthopedic clinics, Surgical centers, Isolation areas, Recovery rooms, Transport vehicles, Vet of�ces and clinics

This product is approved for use on medical equipment surfaces. See label for details.DIRECTIONS FOR USE: It is a violation of Federal Law to use this product in a manner inconsistent with its labeling.

This product is not to be used as a terminal sterilant/high level disinfectant on any surface or instrument that (1) is introduced directly into the human body, either into or in contact with the bloodstream or normally sterile areas of the body, or (2) contacts intact mucous membranes but which does not ordinarily penetrate the blood barrier or otherwise enter normally sterile areas of the body. This product may be used to pre-clean or decontaminate critical or semi-critical medical devices prior to sterilization or high-level disinfection.

DISINFECTION DIRECTIONSTO DISINFECT HARD, NONPOROUS SURFACES: Visible soil must be removed prior to disinfecting by pre-cleaning the surface. Wipe surface until completely wet. Treated surfaces must remain wet for appropriate contact time listed below. Allow to air dry or wipe with a clean cloth or paper towel after appropriate contact time has expired. A water rinse is not required.TO DISINFECT NON-CRITICAL PRE-CLEANED INSTRUMENTS: Visible soil must be removed prior to disinfecting by pre-cleaning the surface. Wipe instruments until surfaces are completely wet. Treated surfaces must remain wet for appropriate contact time listed on this label. Allow to air dry or wipe with a clean cloth or paper towel after appropriate contact time has expired. A water rinse is not required.

SANITIZATION DIRECTIONSTO SANITIZE HARD, NONPOROUS FOOD CONTACT SURFACES¥ : Visible soil must be removed prior to sanitizing by pre-cleaning the surface. Wipe surface until completely wet. Treated surfaces must remain wet for 60 seconds. Allow to air dry or wipe with a clean, cloth or paper towel after 60 second contact time has expired. A water rinse is not required.

SPECIAL INSTRUCTIONS FOR CLEANING AND DECONTAMINATION AGAINST HIV-1, HBV and HCV ON SURFACES/OBJECTS SOILED WITH BLOOD OR BODY FLUIDS: This product kills HIV, HBV and HCV on pre cleaned environmental surfaces/objects previously soiled with blood/body �uids in healthcare settings or other settings in which there is an expected likelihood of soiling of inanimate surfaces/objects with blood/body �uids and in which the surfaces/objects likely to be soiled with blood/body �uids can be associated with the potential for transmission of Human Immunode�ciency Virus Type 1 (HIV 1) (associated with AIDS) [Human] Hepatitis B Virus (HBV) and [Human] Hepatitis C Virus (HCV) Personal Protection: When handling items soiled with blood or body �uids use disposable impervious gloves, gowns, masks and eye coverings. Cleaning Procedures: Blood and body �uids must be thoroughly cleaned from surfaces and objects before application of this product. Contact time: Wipe surface until completely wet and let stand for 20 seconds. Note: contact times for other micororganisms on this label may vary. Infectious Materials Disposal: Blood and other body �uids should be autoclaved and disposed of according to local regulations for infectious disposal.

Medical Equipment Surfaces:Dental chairs, Dental unit instrument trays, dental curing lights, Operating tables, Examination tables, X-ray tables, Patient care equipment, MRI machines, Dialysis machines, External ultrasound transducers and probes, Chemotherapy hoods, Oxygen hoods, CAT scans, stretchers, medical carts, Blood pressure monitors, gurneys, stethoscopes, diagnostic equipment, Patient support and delivery equipment, Infant incubators, Blood glucose meters

TO OPEN PACKAGE: Flip open dispensing cap and remove entire lid from canister by lifting upward. Locate wipe at center of roll, twist corner to a point and thread through small opening in lid. DO NOT PUSH FINGER THROUGH OPENING. Replace lid and pull sheet up at an angle. Remaining wipes feed automatically. When �nished, snap lid cap shut to retain moisture.

NO BLEACH

• N

O HARSH FUM

ES •

KILLS: MRSA1, HBV†, HCV†, HIV-1†, INFLUENZA A†

*FRAGRANCE FREE, ONE-STEP DISINFECTANT, SANITIZER, DEODORIZER, CLEANER

Hard, Nonporous High Touch Surfaces:Bed frames, railings and matresses, Bedside tables, IV poles, wheelchairs, walkers, nurse call buttons, cabinet handles, keyboards, light switches, door knobs, ¥tables, chairs, stools, ¥counters, carts, telephones, handrails, mobile workstations, electronic screens, keyboards, handheld electronic devices, ¥childrens toys

Hard, Nonporous Use Surfaces:Acrylic, chrome, �nished wood**, glazed tile, �berglass surfaces, laminate, metal, plastic, glazed porcelain, stainless steel, vinyl

HEALTHCARE

SURFACEDISINFECTING WIPES

EPA Reg. No. 84150-1 EPA Est. No.: 84150-OH-001 (CF), 84150-OH-002 (WR), 84150-OH-003 (ST), 73027-WI-1 (MP), 50757-WI-1 (GN), 50757-WI-2 (GY) Beginning of batch code indicates EPA Est. No.

Distributed by: GOJO Industries, Inc., PO Box 991, Akron, OH 44309Ingredient information / Questions? Tel: 1-888-4-PURELL©2018. GOJO Industries, Inc. All rights reserved. Made in U.S.A.

DISINFECTS FOOD CONTACT SURFACES, NO RINSE REQUIRED

THICK, DURABLE WIPE

LEAVES NO DULL OR STICKY RESIDUE

BROAD SPECTRUM DISINFECTANT

NOT FOR USE ON SKIN

NOT FORPERSONALCLEANING

NOT FORUSE AS A

BABY WIPE

84150-1_Purell Healthcare Surface Disinfecting Wipes_20190529_9_84150_.pdf