    FP5121

    ELECTRONICS PVT. LT

    RENU

    FlexiPanels

    12.1" TFT

    Color Touch Scr

  • 7/27/2019 FP5121

    2/5

    alient Features :-

    12.1 Graphical Touchscreen TFT Color Display

    Ladder editor with powerful instruction set

    Support for Recipes and 32K color Bitmaps

    Communication Ports:

    Two serial ports to connect PLC at RS232 / 422 / 485 levels / Printer / Programming Port

    One USB (Device) port as Programming Monitoring Port

    One USB (Host) port to connect USB memory drive

    One optional Ethernet port (10/100 Mbps. Modbus TCP/IP)

    Dual Port communication supported

    Data Logging, Transfer logged data on USB memory drive

    Floating point support, Alarms and Trending (Real Time and Historical), RTC

    Multilanguage (Unicode) support with true type Windows fonts for graphical models

    IP66 design. CE, UL approved. RoHS compliant

    Common Programming software for the entire FlexiPanels family.........FREE!!

  • 7/27/2019 FP5121

    3/5

    Operations :-

    e FlexiPanels support Operator interface as well as Programmable Logic Controller Counter-

    tures. The user can implement logic, specific to application using standard Ladder Up counter UP Down Counter

    ogramming. A PLC logic block can be executed at power up, during every scan, upon Program Control -eiving an interrupt on specific I/O pins or upon a timer interrupt. The FlexiPanels

    Subroutine CALL Subroutine RET Forerator interface functions revolve around Screens and Tasks that can be assigned to

    Next Master Control Set Master Control Reseteens and application.

    Jump Control Set Jump Control Reset En Intr

    Dis Intr DT Step sequence Inituch Keys Task Step sequence Input Step sequence outputuch Keys in FlexiPanels can be assigned Tasks for three instances: when the screen is

    uched, while the screen is touched and when the screen is released. Multiple tasks can

    Function -assigned to a touch key. In addition to above, tasks for data entry, alarm management

    Moving Average Digital Filter PID1,4. can be defined. These definitions allow Complete flexibility in cursor control and key

    Upper limit Lower limit Maximum Valueerations when changing data.

    Average Value Function generator Minimum Value

    arms Special -al time and historical Alarms can be defined in FlexiPanels . User-friendly Alarm object

    Device Set Device Reset Register Setn be defined on the display. Alarms can be real time or historical.

    Register Reset Set Carry Reset Carry

    Encode Decode Bit Count Flip Flopcipes Direct I/O Set Calender Calender Operationcipes data is stored in the FlexiPanels memory. With one button stroke, a set of data

    n be downloaded to the PLC. Once in the local memory, the recipes data can be edited

    The execution of ladder logic is in microseconds. Ladder monitoring for debugging is alsong simple data entry objects.

    supported in FlexiPanels configuration software.

    maps / Wizards Multilanguage / Unicode Supportferent bitmaps can be embedded on the FlexiPanels screen. Transparent buttons can

    All the languages are supported in the FlexiPanels (Color Touchscreen based models) . Theused for data entry and set points on bitmap images. Bitmaps can be imported into the

    can now display messages, alarms in any regional language. All Windows fonts can also beplication and displayed on the FlexiPanels screens. In addition, several wizards arein an application.pported to create commonly used objects such as Analog meters, Lamps, Buttons and

    r graphs. 32K colors are supported for bitmaps.

    Communication Ports

    FP5121 has two serial communication ports. Both the ports can be used for programming osy events logging and trend tracking FlexiPanels , printing screens (only text), connecting to third party serial devices (barcode5121 models support data logging feature. A part of FlexiPanels memory can be

    readers, temp scanners etc.) or to connect to a PLC or drive.otted for data logging. Real time as well as Historical Trending is also supported. The

    Dual port feature is supported for FP5121. User can configure these serial ports to connect er can also display multiple trends with different pen color on one screen.

    different devices supporting different protocols, such as PLC / Drives / DCS / SCADA etc.

    dder Support It has one USB (Device) port. The USB port can be used as a programming port or for laddexiPanels support ladder functionality. User can define logic in the unit using FlexiSoft

    monitoring. The unit also has one USB (Host) port. The USB Host port can be used to conntware. The execution of ladder could be through communication port or through I/O. memory drive.ly HMI version of FlexiPanels also support ladder functionality. It is used for critical

    plications where data is processed before sending it to controller. The FlexiLogics

    Ethernet Portpport following different types of instructions :

    FlexiPanels support optional Ethernet port (Modbus TCP/IP). It can be used to connect to a

    and monitor machine / process status from remote location. The Ethernet port can also be uInstructions -

    for remote programming of FP5121.O contact NC contact Output

    ling Edge Rising Edge Inverter

    Configuration Softwareverter Coil Positive Pulse Contact Negative Pulse Contact

    FlexiSoft is a compact, Windows based software to configure the FlexiPanels units. Usersitive pulse coi l Negative Pulse Coi l

    friendly configuration tools and easy approach, helps user create applications quickly and ea

    ta Transfer -

    OV word MOV DWORD Invert Transfer

    ble Initialize Table Block Transfer Table Invert Transfer

    ta Exchange Multiplexer Demultiplexer

    ath-

    dition Subtraction Multiplication

    vision Addition with Carry Subtraction with Carry

    crement Decrement

    mpare -

    eater than Greater than or equal Equal

    t Equal Less Than Less than or Equal

    gic -

    D OR XOR

    ift Rotate

    To get started with FlexiPanels , user needs:ta Conversion -

    1. FlexiPanels unit 2. FlexiSoft Softwarex to Ascii Ascii to Hex Absolute Value

    3. USB Programming cable (Part no. PC-USBAB-00)segment decode Ascii conversion Binary Conversion

    D conversion 2's complement word 2's complement Double word

    OS requirements for FlexiSoft are:

    mer - Windows Version : Microsoft Windows 2000 or above

    N TOFF TSS

  • 7/27/2019 FP5121

    4/5

    upported Task in FlexiPanels are :-

    Driver FP5121

    Allen Bradley DF1

    Aromat FP Series

    Danfoss Drive

    ABB

    Delta

    Baldor

    Fatek

    GE Fanuc

    GE SNP-X

    Driver FP5121

    Mitsubishi Q series (Serial)

    LG Master K series

    LG Master-K 300S

    Modbus master

    Mitsubishi FX

    Idec

    Omron Yaskawa Drive

    Omron Host Link

    Modbus slave

    Driver FP5121

    Toshiba T2 Link port

    Serial Monitor

    Siemens-S7-200

    Siemens-S7-300

    Toshiba Inverters

    Universal Serial (ASCII)

    Toshiba T1

    UnitelwayTwido

    Protocols Supported for :-

    Write value to tag

    Add constant to tag

    Subtract constant from tag

    Add tag B to Tag A

    Subtract tag B from Tag A

    Turn bit ON

    Turn bit OFF

    Toggle bit

    Copy Tag B to Tag A

    Swap Tag A and tag B

    Copy HMI block to HMI/PLC block

    Copy HMI/PLC block to HMI block

    USB Data Log Upload

    Print Data

    Set RTC

    Copy RTC to PLC block

    Copy tag to STR

    Go to screen

    Go to next screen

    Go to previous screen

    GoTo Popup screen

    Wait

    Delay

    Copy tag To LED

    Task

    Type

    Power up Global Before

    showing

    While

    showing

    Screen

    After

    hiding

  • 7/27/2019 FP5121

    5/5

    Dimensions :-

    lease contact factor y for more information. We welcome an opportunity to develop new, custom drivers and customized units.

    (Specifications subject to change without prior notice DS-FP5121

    All dimensions are in mm.

    An ISO 9001 : 2008 and ISO 14001 : 2004 certified company

    FACTORY

    Survey No. 2/6, Baner Road, Pune - 411045, India.

    Tel : +91 20 2729 2840 Fax : +91 20 2729 2839

    Email : [email protected]

    Website: www.renuelectronics.com

    One D type port that supports RS232 and RS485 levels on different pins. Y type cable can be used for separate RS232 and RS485 levels simultaneously.

    Model Comparison :-t Model PLC

    Steps

    Memory Screen

    Memory

    Logging

    Memory

    Serial**

    Ports

    USB RTCEthernet

    Port

    Power

    Consumption

    Weight Panel CBezel Dimensions (mm)

    1

    Display LCD LifeO

    at 25 C

    FP5121TDevice

    and Host

    Yes160 kUp-to

    14 MB

    293 W 312 W x 246 H x 48 D

    (Drawing D)

    1.680 Kg16WNo2YesUp-to

    10 MB

    800x600 SVGA

    12.1" Color TFT

    70000 hrs

    Device

    and Host

    TS

    Yes

    Yes Yes160 kUp-to

    14 MB

    800x600 SVGA

    12.1" Color TFTFP5121TN 293 W

    312 W x 246 H x 48 D

    (Drawing D)

    Drawing D

    1.680 Kg16WYes2YesUp-to

    10 MB70000 hrs

    312

    200

    225

    246

    293

    238

    Mounting Clamp

    48

    upported Printers :-

    exiPanels support following Dot matrix serial printers :

    EPSONSAMSUNGTVS

    pecifications :-

    wer : + 24V DC 15%, 16W Type of LCD : TFT Color Touch ScreenO

    LCD Life : 70000 hrs at 25 Czel : IP66 rated Touch ScreenO O

    perating Temperature : 0 to 50 C Supported Colors : 32K for Color TFT LCDO O

    orage Temperature : -20 to 80 C Immunity to ESD : as per IEC61000-4-2

    umidity : 10% to 85% (Non condensing) Immunity to Fast Transients : as per IEC61000-4-4

    mmunication Ports : Two serial ports (RS232 / RS422 Immunity to Radiated

    / RS485 levels supported) Electromagnetic field : as per IEC61000-4-3

    SB Device Port : As programming and monitoring port Immunity to

    SB Host port : Supports USB Memory drive Conducted disturbances : as per IEC61000-4-6

    hernet Port : For connecting to a PLC, Surge : as per IEC61000-4-5, Radiated emission : as per EN55011Programming of FlexiPanels a

    third party device,Drive or remote

    monitoring (10 / 100 MBPS).