  • 8/11/2019 For the Steam and Condensate Loop_01

    1/4

    Applications overview

    for the steam and condensate loop

  • 8/11/2019 For the Steam and Condensate Loop_01

    2/4

  • 8/11/2019 For the Steam and Condensate Loop_01

    3/4

    Jacketed heating pan

    Shell and tube

    heat exchanger

    Flow

    Return

    Condensate

    from others

    To boiler

    feedtank

    To condensate

    receiver unit

    Flow

    Plate heat

    exchanger

    Return

    traps

    odynamic

    lable:-

    pressure

    bucket

    Pipeline ancillaries

    36Strainers

    37Air vents38Sight glasses39Pressure gauges40 Vacuum breakers

    Pipeline ancillaries

    41Separators42Check valves43Steam trap monitors44 Manual and actuated ball valves

    45Stop valves46 Bellows sealed stop valves

    Steam humidification

    47 Steam injection humidifiers

    Also available:-Self-generative humidifiers

    Clean / pure steam

    Many of the products shown are alsoavailable for clean or pure steam

    applications in the biotechnology,pharmaceutical, food and drinkindustries.

    Flash steam recovery

    48 Flash vessels are used to convert pressurised condensate into useful

    flash steam - used here on the

    first stage of an air heater battery.

    Condensate recovery

    49 Combined pump traps and pressurepower pumps for condensate

    removal and return (no electrics).

    50 Electric pump sets used where

    condensate can freely draininto a receiver.

    Engineered Systems

    A complete, compact steam heatexchange solution for process, heating,and domestic hot water requirements.

    The environment

    Steam has always been environmentallyfriendly - modern, highly efficientcentralised boiler plant ensures

    emissions are minimised and the steamitself condenses to pure, unpollutedwater.

    Spirax Sarco remain at the forefront ofimproving the efficiency of the entiresteam and condensate loop and are theonly company with this total capability.

    Steam specialisation, condensate handling and the environment

    Air

    Air duct

    Air

    General layout only,some of the detail has been omitted for clarity. Your local Spirax Sarco engineer will be pleased to advise.

    30

    32

    40

    45

    37

    4535

    42

    44 34 44

    39

    44 37

    26

    28 46

    46

    30

    26

    47

    44

    44

    38

    35

    36

    19

    48

    44 37

    44

    49

    50

    32

    36

    46

    30

  • 8/11/2019 For the Steam and Condensate Loop_01

    4/4