Dear Mr. Sajid Hussain Shah,  Reference our discussion today regarding a possible project with yourself for packaging, sourcing, supervising a installation/commissioning of a Turbine Generator in Punjab. We have purchased a 7.83 MW Turbine Generator from Europe. Photo's attached. The Turbine Generator was installed at a sugar plant which was liquidated 2 years ago. The liquidator only saved the Turbine, Gear and Alternator. All auxilaries of the Turbine Generator were destroyed by the plant liquidator and are missing. Following is a list of components that are missing from the Turbine Generator: Turbine Generator Panel including excit ation control s ystem? We require engineering and quotation of the Turbine Generator Panel. Lubricating oil system (reservoir, reservoir demister, heater, main oil pump, aux. oil  pump, emergency (DC) oil pump, duplex filters, duplex coolers, piping, valves and instruments). Including Hydraulic Goveronor Contr ol System. We re quire a quotation from your company. The heat exchangers required f or oil cooling are available locally in Pakistan. Heat Exchanger Sizing is an issue which needs to be provided by your company. Turbine Local Panel can als o be sourced locally in Pakistan. However, all drawing and engineering would have to be provided by you, alternatively please quote this item. Couplings. We will require the high speed coupling be tween the Turbine and Gear and also the low speed coupling between the Gear and Alternator. Oil conditioning system (de-watering system). Gland condenser system (ejectors, heat exchanger, piping, valves and instruments). We need sizing of t he heat exchanger. Please quote your best p rices, however i thi nk if your companyt provides the heat exchanger sizing, we can have them purchased locally as they would be more price competitive. Alternator cooling water pump sizing. Cooling water supply s ystem (duplex pumps, piping, va lves and instruments). We need sizing of the heat exchangers. Excitation control system (panel). All valves, fittings and instrumentation is available locally in Pakistan at very competitive  prices. All interconnecting pipi ng for oil system w ould have to be done. The Alternator has CACW cooling system.  

Upload: mian-ahsan

Post on 09-Apr-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: For Prints

8/8/2019 For Prints

http://slidepdf.com/reader/full/for-prints 1/8

Dear Mr. Sajid Hussain Shah,

 

Reference our discussion today regarding a possible project with yourself for packaging,

sourcing, supervising a installation/commissioning of a Turbine Generator in Punjab.

We have purchased a 7.83 MW Turbine Generator from Europe. Photo's attached. The

Turbine Generator was installed at a sugar plant which was liquidated 2 years ago.

The liquidator only saved the Turbine, Gear and Alternator. All auxilaries of the Turbine

Generator were destroyed by the plant liquidator and are missing.

Following is a list of components that are missing from the Turbine Generator:

• Turbine Generator Panel including excitation control system? We require

engineering and quotation of the Turbine Generator Panel.• Lubricating oil system (reservoir, reservoir demister, heater, main oil pump, aux. oil

 pump, emergency (DC) oil pump, duplex filters, duplex coolers, piping, valves and

instruments). Including Hydraulic Goveronor Control System. We require a

quotation from your company.

• The heat exchangers required for oil cooling are available locally in Pakistan. Heat

Exchanger Sizing is an issue which needs to be provided by your company.

• Turbine Local Panel can also be sourced locally in Pakistan. However, all drawing

and engineering would have to be provided by you, alternatively please quote this

item.

• Couplings. We will require the high speed coupling between the Turbine and Gear 

and also the low speed coupling between the Gear and Alternator.

• Oil conditioning system (de-watering system).

• Gland condenser system (ejectors, heat exchanger, piping, valves and instruments).

We need sizing of the heat exchanger. Please quote your best prices, however i think 

if your companyt provides the heat exchanger sizing, we can have them purchased

locally as they would be more price competitive.

• Alternator cooling water pump sizing.

• Cooling water supply system (duplex pumps, piping, valves and instruments). We

need sizing of the heat exchangers.

• Excitation control system (panel).

All valves, fittings and instrumentation is available locally in Pakistan at very competitive

 prices. All interconnecting piping for oil system would have to be done.

The Alternator has CACW cooling system.

 

Page 2: For Prints

8/8/2019 For Prints

http://slidepdf.com/reader/full/for-prints 2/8

We will also require following missing components:

 

•  Neutral earthing resistor. (Available Locally, we would require sepcifications)

• Low Voltage electrical equipment (motor control panels)• High Voltage electrical equipment (including bus bars and high voltage breaker)

• Direct current electrical system (powering DC oil pump, if required).

• Special tools.

We need engineering services to provide specification of missing components, supply of 

missing components as per above list, services for supervision of installation/commissioning

of the Turbine Generator.

We will facilitate all support structure at site. We will provide lodging, food, tools and

necessary infra-structure during the project at the Site. An overhead crane is available in the

 power house. The Turbine Generator is expected to arrive in Pakistan by July 30, 2010

We are sending the Turbine Generator Manual, drawings, photo's and all the relevant data

that may help you establish a commercial proposal for supply of missing components

and also commercial offer for services.

I look forward to your feedback.

Regards

Asad Ali - Managing Director 

Spectra ID (Pvt) Ltd 

1 D9 Sector 21, Korangi Industrial Area,

Karachi, Pakistan

Tel: +92 21 706-5321

E-mail: [email protected]

www.spectraid.com

Mobile +92 300 203-2345

Page 3: For Prints

8/8/2019 For Prints

http://slidepdf.com/reader/full/for-prints 3/8

Page 4: For Prints

8/8/2019 For Prints

http://slidepdf.com/reader/full/for-prints 4/8

Page 5: For Prints

8/8/2019 For Prints

http://slidepdf.com/reader/full/for-prints 5/8

Page 6: For Prints

8/8/2019 For Prints

http://slidepdf.com/reader/full/for-prints 6/8

Page 7: For Prints

8/8/2019 For Prints

http://slidepdf.com/reader/full/for-prints 7/8

Page 8: For Prints

8/8/2019 For Prints

http://slidepdf.com/reader/full/for-prints 8/8