for global market violin tmii - lieckipedia gmbh · 2019. 1. 17. · for global market violin tmii...

2
For Global Market VIOLIN II TM Baseline CHSM6610P Series Baseline CHSM6610P/HV Series Crystalline PV Module With innovational 4-busbar cells Unique PERC technology with optimized module process CHSM6610P max system voltage 1000V standard, CHSM6610P/HV max system voltage 1500V standard 0/+5 Wp - 0.407%/K +0.049%/K - 0.000%/K - 0.408%/K - 0.310%/K 43±2°C Warranted power output STC (Pnominal) Rated voltage (Vmpp) at STC Rated current (lmpp) at STC Open circuit voltage (Voc) at STC Short circuit current (Isc) at STC Module efficiency Rated output (Pmpp) at NOCT Rated voltage (Vmpp) at NOCT Rated current (Impp) at NOCT Open circuit voltage (Voc) at NOCT Short circuit current (Isc) at NOCT Temperature coefficient (Pmpp) Temperature coefficient (Isc) Temperature coefficient (Impp) Temperature coefficient (Vmpp) Temperature coefficient (Voc) STC rated output (Pmpp)* PTC rated output (Pmpp)** ELECTRICAL SPECIFICATIONS Standard sorted output 275 280 285 290 290 Wp 268.7 Wp 290 Wp 31.55 V 9.20 A 39.18 V 9.75 A 17.8% 217.5 Wp 28.56 V 7.62 A 35.79 V 8.21 A 280 Wp 259.2 Wp 280 Wp 31.20 V 8.99 A 38.69 V 9.59 A 17.2% 210.0 Wp 28.22 V 7.44 A 35.35 V 8.08 A * Measurement tolerance +/- 3% ** Estimated Normal operating cell temperature (NOCT) EN 6 (or 3) 15 A Maximum system voltage (IEC/UL) Number of diodes Maximum series fuse rating 1000VDC / 1000VDC or 1500VDC / 1500VDC 285 Wp 263.9 Wp 285 Wp 31.38 V 9.09 A 38.94 V 9.68 A 17.5% 213.8 Wp 28.41 V 7.52 A 35.57 V 8.15 A 275 Wp 254.4 Wp 275 Wp 31.12 V 8.85 A 38.45 V 9.52 A 16.9% 206.3 Wp 28.15 V 7.33 A 35.13 V 8.02 A IEC TS 62941

Upload: others

Post on 27-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • For Global Market

    VIOLIN IITM

    VIOLIN TM

    Baseline CHSM6610P SeriesBaseline CHSM6610P/HV Series

    Crystalline PV Module

    With innovational 4-busbar cellsUnique PERC technology with optimized module process

    CHSM6610P max system voltage 1000V standard, CHSM6610P/HV max system voltage 1500V standard

    0/+5 Wp

    - 0.407%/K

    +0.049%/K

    - 0.000%/K

    - 0.408%/K

    - 0.310%/K

    43±2°C

    Warranted power output STC (Pnominal)

    Rated voltage (Vmpp) at STC

    Rated current (lmpp) at STC

    Open circuit voltage (Voc) at STC

    Short circuit current (Isc) at STC

    Module effi ciency

    Rated output (Pmpp) at NOCT

    Rated voltage (Vmpp) at NOCT

    Rated current (Impp) at NOCT

    Open circuit voltage (Voc) at NOCT

    Short circuit current (Isc) at NOCT

    Temperature coeffi cient (Pmpp)

    Temperature coeffi cient (Isc)

    Temperature coeffi cient (Impp)

    Temperature coeffi cient (Vmpp)

    Temperature coeffi cient (Voc)

    STC rated output (Pmpp)*

    PTC rated output (Pmpp)**

    ELECTRICAL SPECIFICATIONS

    Standard sorted output

    275 280 285 290

    290 Wp

    268.7 Wp

    290 Wp

    31.55 V

    9.20 A

    39.18 V

    9.75 A

    17.8%

    217.5 Wp

    28.56 V

    7.62 A

    35.79 V

    8.21 A

    280 Wp

    259.2 Wp

    280 Wp

    31.20 V

    8.99 A

    38.69 V

    9.59 A

    17.2%

    210.0 Wp

    28.22 V

    7.44 A

    35.35 V

    8.08 A

    * Measurement tolerance +/- 3%** Estimated

    Normal operating cell temperature (NOCT)

    EN

    6 (or 3)

    15 A

    Maximum system voltage (IEC/UL)

    Number of diodes

    Maximum series fuse rating

    1000VDC / 1000VDCor 1500VDC / 1500VDC

    285 Wp

    263.9 Wp

    285 Wp

    31.38 V

    9.09 A

    38.94 V

    9.68 A

    17.5%

    213.8 Wp

    28.41 V

    7.52 A

    35.57 V

    8.15 A

    275 Wp

    254.4 Wp

    275 Wp

    31.12 V

    8.85 A

    38.45 V

    9.52 A

    16.9%

    206.3 Wp

    28.15 V

    7.33 A

    35.13 V

    8.02 A

    IEC TS 62941

  • © Chint Solar (Zhejiang) Co., Ltd. Reserves the right of final interpretation.Specifications and designs included in this datasheet are subject to change without notice.

    01-2017

    RELATED PARAMETERS QUALIFICATION AND LINEAR WARRANTIES

    Product standard IEC 61215, 61730 / UL1703

    1st year

    2nd~ 25th years

    Extended product warranty

    Output decline 2.5%/year performance Pmpp (STC)

    Output decline 0.7%/year performance Pmpp (STC)

    Number of cells / cell arrangement

    Cell type

    Cells dimension

    Packing unit

    Polycrystalline

    60 / 6 x 10

    6”

    28 modules

    10 years

    MECHANICAL SPECIFICATIONS

    Outer dimensions (L x W x H)

    Frame technology

    Module composition

    Weight (module only)

    Front glass thickness

    Junction box IP rating

    ① Cable length (UL/IEC)

    Cable diameter (UL/IEC)

    ② Maximum load capacity

    Fire performance (UL/IEC)

    Connector type ( UL/IEC)

    Front view

    Aluminum, silver anodized

    Glass / EVA / Backsheet (white)

    3.2 mm / 0.13 in

    IP 65 (above)

    900(+)/600(-)mm / 35.43/23.62 in

    12 AWG / 4 mm²

    2400 Pa

    Type 1 (UL) or Class C (IEC)

    MC4 compatible

    MODULE DIMENSION DETAILS

    Side view Frame cross sectionRear view

    18.3 kg / 40.34 lbs

    1648 x 990 x 35 mm64.88 x 38.98 x 1.38 in

    ① Option: 1000 mm for defined projects in advance.

    990 mm/3.248 feet 35 mm/0.115 feet

    35 mm/ 0.115 feet

    11mm/ 0.036 feet

    35 m

    m/0

    .115

    feet

    1648

    mm

    /5.4

    07 fe

    et

    80.70%

    0 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5

    Linear Performance Wanrranty100.00%

    95.00%

    90.00%

    85.00%

    80.00%

    75.00%

    97.50%

    ARTICLE NUMBER

    Model Article No. (IEC) Article No. (UL)

    (VIOLIN II) CHSM6610P-275

    (VIOLIN II) CHSM6610P-280

    (VIOLIN II) CHSM6610P-285

    (VIOLIN II) CHSM6610P-290

    (VIOLIN II) CHSM6610P/HV-275

    (VIOLIN II) CHSM6610P/HV-280

    (VIOLIN II) CHSM6610P/HV-285

    (VIOLIN II) CHSM6610P/HV-290

    Weight of packing unit (for container) 557 kg / 1228 lbs

    100

    mm

    /0.3

    28 fe

    et

    946 mm/ 3.104 feet

    Mounting hole

    6-Φ5.5 mm / 0.018 feet

    16-3.5 mm x8.5 mm/ 0.011 feet x0.028 feet

    6-7 mm x11.5 mm / 0.023 feet x0.038 feet

    Drainage hole

    Ground hole 824

    mm

    /2.7

    03 fe

    et

    198

    mm

    /0.6

    50 fe

    et

    600

    mm

    / 1.

    97 fe

    et

    900

    mm

    / 2.

    95 fe

    et

    ② Refer to Astronergy crystalline installation manual.

    200601

    200641

    200684

    200685

    500082

    500084

    500100

    500101

    200602

    200642

    200686

    200687

    500083

    500085

    500102

    500103