follow-me charge stage coordination and what to expect out of multiple charge controllers....
TRANSCRIPT
Follow-Me charge stage coordination and what to expect
out of multiple charge [email protected]
Ryan, Technical Support [email protected]
360-403-7207 XT151
*Multiple Charge controllers without Follow-Me*Multiple Charge controllers with Follow-Me*Follow-Me
*Controllers each need a Battery temp sensor*Equalize needs to be started on each controller*Float charges not coordinated *Displays needed for each controller
*1 battery temp sensor needed*EQ, manual or Auto can be controlled by a single controller*Going to Float is coordinated*Single display can view all Follow-Me Classic’s
Programming Follow-Me
Press “Main Menu” and then use the arrows to scroll to “Tweaks” and press “Enter”
Programming Follow-Me
Press the button labeled “More” and Press it again for “More2”
Programming Follow-Me
Press the button labeled “More3” and Press it again for “More4”
Programming Follow-Me
*Set the number for FollowMe*Turn BTS-NET on if wanted*Enter to save*Status button to return to “Home” screen
Ground fault sharing
*Enable ground fault Hardware and software on one Classic only*Enable ground fault Software on any additional Classic’s you wish to turn off on GF
Naming the Classic
*Use the Local App to name the Classic*Name shows up on the display of each Classic making navigating multiple Classic’s easier
Addressing each Classic for viewing on a single MNGP
*Hold Left arrow and tap up or down to change address*Find an unused address to address that Classic to and press and hold left and right arrow till saved (Classic is address 10 by default)*Use the MNGP to address any Lite’s*Hold left arrow and tap up or down arrow to view different Classics on the Follow-Me network
Programming the Classic Lite for Follow-Me
*Use the standard Classic’s MNGP and physically plug it into each Lite and follow the steps from earlier to enable Follow-Me, Battery temp sharing and Addressing of the Lite (If wanted)*Set the MNLP to Custom and plug it in. *MNLP’s from serial # 5435 or older will not work with Follow-Me, either leave them unplugged or contact us for a replacement
*Absorb time and voltage must be set on all*Float voltage must be set on all*EQ time and voltage must be set on all*LED1 mode gives visual indication of function*Wind Synch*Cloned settings
Questions?
Ryan StankevitzMidNite Solar360-403-7207 XT [email protected]