- Telecom Applications -
Solar Power Supplies for
Telecom Applications
FOLGAT AG Frankfurt am Main Germany
-
7/29/2019 Folgat Solar Telecom Applications
2/16
- Telecom Applications -
As mobile network expansion moves ostensibly to emerging markets where solar
energy levels are more favorable, solar power appears ready to play an important role
in reducing the costs of cellular service delivery and ensuring a more reliable power
supply. The OEMs drive toward reducing base station power consumption, along withimprovements in photovoltaic cells, have meant that solar energy is now a very viable
solution for powering cellular base stations.
335,000 Cellular Base Stations to Include Solar Power by 2013
Mobile networks go green
ABI Research Company , USA / Mobile Networks Research Report
www.abiresearch.com
Solar power will first be used in conjunction with other primary energy sources such as
diesel or grid-based electricity, but will increasingly be seen as a primary source for
autonomous cell sites. The market for autonomous solar powered cell sites looks set to
grow from extremely modest levels today to over 40,000 renewable energy sites by theend of 2013. A further 295,000 base stations are expected to supplement on-grid
power usage with solar.
2
-
7/29/2019 Folgat Solar Telecom Applications
3/16
- Telecom Applications -
Utility Grid
Diesel GenSet
Solar Power Supply
Hybrid System: Solar / Wind
Hybrid System: Solar / Wind / GenSetHybrid: Utility Grid / GenSet
Hybrid: Utility Grid / Back-up Batteries
A short review about Power Supplies forTelecom Applications
Basically there are the following possibilities to supply energy to BTS (Basic
Telecommunication Stations) in remote areas:
The most economic possibility is to use renewable energy systems or
combined systems. Here we would like to introduce solar energy systems as
a reliable and cost efficient solution.
3
-
7/29/2019 Folgat Solar Telecom Applications
4/16
- Telecom Applications -
The most disadvantages of Diesel Aggregates are:
Dependence of fuel (world-wide increase of oil prices; limited resources
in future)
Transport to the sites (long distances and cost intensive transports) Storage of the fuel at site (safety problems - explosions, vandalism, etc.)
No unintended operation is possible (high personal cost)
High maintenance cost (oil, filters, etc.)
Limited life-time of Diesel motors (change of motors every two years) Pollution (noise, heat and dirt)
The most advantages of Solar Systems are:
Independence of oil, gas and utility gridMost economic operation (very low running costs)
Unintended operation (normally no operation personal is required)
Long lifetime (only the batteries must be changed every 5 8 years)
No pollution, no noise, no dirt
Comparison of Solar and Diesel power supply for BTS
4
-
7/29/2019 Folgat Solar Telecom Applications
5/16
- Telecom Applications -
Solar Powered BTS in remote areas
Front viewTotal view
The Kingdom of Saudi Arabia
5
-
7/29/2019 Folgat Solar Telecom Applications
6/16
- Telecom Applications -
All system is inside the
bunker
Photovoltaic systems of high-level security
Also Installations of container type
(in 20-foot containers)
6
-
7/29/2019 Folgat Solar Telecom Applications
7/16
- Telecom Applications -
Battery blocks with inter-connectors and recombination devices theyare necessary, of course, only for flooded battery types like OPzS
Applied Solar Batteries
7
-
7/29/2019 Folgat Solar Telecom Applications
8/16
- Telecom Applications -
Charge-Discharge-Controller / up to 16 kW (240A; 48V)
8
-
7/29/2019 Folgat Solar Telecom Applications
9/16
- Telecom Applications -
Charge-Discharge-Controller / up to 16 kW (240A; 48V)
9
-
7/29/2019 Folgat Solar Telecom Applications
10/16
- Telecom Applications -
SUW 200 can be used in solarapplications to convert DC powerfrom solar modules or AC power fromgen-set into 48VDC. The basic task ofthe SUW 200 power supply system isto supply main telecom equipment(telecom exchanges, GSM base etc.)
with Uninterruptible DC power.
Selectiva PLUS 4080 48V / 80A
Selectiva PLUS 4120 48V / 120A
Rectifier Devices
10
-
7/29/2019 Folgat Solar Telecom Applications
11/16
- Telecom Applications -
Monitoring and Data Transfer System
Remote
Site BTS
Remote
Site BTS
Remote
Site BTS
Remote
Site BTS
1
.. 2000
OfficeComputer
withModem
Internal Network
Server
Handy
DC power supply system and inverter system,
generating set, solar, battery etc.air conditioner,
DC and AC distribution board,
UPS (Uninterruptible Power System),
fire protection system,
others
11
-
7/29/2019 Folgat Solar Telecom Applications
12/16
- Telecom Applications -
Load current and Ampere-Hour
Battery current and Ampere-Hour (calculated)
Array current and Ampere-Hour
Battery Voltage
Shelter temperature
Ambient temperature
Fire alarm status
Battery High Voltage Alarm
Battery Low Voltage Alarm
Water Level Alarm
Door Open Alarm
Solar Insulation Level
Typical parameters which can be monitored are the following:
Monitoring and Data Transfer System
12
-
7/29/2019 Folgat Solar Telecom Applications
13/16
- Telecom Applications -
2 inputs for Ah counting for Load and Array. The battery Ah will be calculated.
5 alarm digital inputs (high voltage, low voltage, fire alarm status, water level
status, intruder alarm), 4 analog inputs (battery voltage, load current, array current, solar insolation),
2 inputs for temperature measurement.
+ Measurements once a minute:
local data collecting of 4 analog (15 min averages from minutesmeasurements), 5 digital quantities, 2 temperatures and 2 Ah counters. (4 datapackets for 1 hour = 96 data packets per day) near 56 KB local memory for onemonth data collection,
local connection and data transfer through RS232,
data transfer once a day (after 0:00AM - all data packets from day before), alarm signals transmission after its appearance.
Remote communication over GSM network CSD or GPRS (with static addressesnecessary).
Controller specification
Monitoring and Data Transfer System
13
-
7/29/2019 Folgat Solar Telecom Applications
14/16
- Telecom Applications -
Economical consideration of DIESEL- and SOLAR poweredtelecom-plants
0
10
20
30
40
50
6070
80
90
100
0 20 40 60 80 100
Solar Power
Diesel Power
break-even pointbelow 20 USD cent
Relative values for annual operating costs
Costs for DIESEL fuel in USD cent
Assumptions: Interest rate = 6 % ; Lifetime of systems = 20 years ; operation in areas with high solar
irradiations (sunbelt ofearth) ; price increase of DIESEL fuel = 5% per anno;
Even below 20 USD cents for fuel a SOLAR powered system operates more economic
than DIESEL powered stations!
14
-
7/29/2019 Folgat Solar Telecom Applications
15/16
- Telecom Applications -
Providing with solar cells, solar modules, solar inverters
Planning/Consulting
Outsource design and installation works
Monitoring
Service
FOLGAT AG is a provider of solutions and products (solar cells, solar
inverters, modules, systems) for the photovoltaic electricity generation. We
intensively collaborate with the numerous companies along the entire value
chain of PV products at regional, national, European and International level.
FOLGAT AG / Solar strategy
15
Business focus
-
7/29/2019 Folgat Solar Telecom Applications
16/16
- Telecom Applications -
FOLGAT AG
Melsunger Str. 9, D-60389,Frankfurt am Main, Germany
tel.: 49 69 95297164
fax: 49 69 95297165
CONTACTS
In partnership with
16