flyer elc 2015 · 2019. 6. 29. · control port profibus harmonic current distortion thdi 33%...
TRANSCRIPT
![Page 1: Flyer ELC 2015 · 2019. 6. 29. · control port PROFIBUS harmonic current distortion THDi 33% efficiency typ. 96% mains voltage 400 V or 480 V, ... Lamp feeder connection mains connection](https://reader035.vdocuments.us/reader035/viewer/2022071011/5fc8f9a1bac9456057776ba7/html5/thumbnails/1.jpg)
ELC®
Electronic Lamp Control
eta plus electronic gmbh
part of the IST METZ group, Lauterstrasse 29, D-72622 Nuertingen, Germany
tel: +49 (0)7022 60 02 813; fax: +49 (0)7022 60 02 888
@: [email protected] www.eta-uv.de Stand: Sept.13
![Page 2: Flyer ELC 2015 · 2019. 6. 29. · control port PROFIBUS harmonic current distortion THDi 33% efficiency typ. 96% mains voltage 400 V or 480 V, ... Lamp feeder connection mains connection](https://reader035.vdocuments.us/reader035/viewer/2022071011/5fc8f9a1bac9456057776ba7/html5/thumbnails/2.jpg)
2/1
9/2
015
2
ELC® general information
The electronic lamp control units ELC®
are designed to power UV medium
pressure discharge lamps. In four
different series we offer fully integrated
electronic lamp control solutions for UV
lamps from 3 kW to 35 kW.
Various air and water based cooling
options offer most flexible and reliable
power system integration. Special
versions are designed for marine
applications such as BWMS, ballast
water treatment on ships.
The ELC® control strategies allow easy
PLC connection via PROFIBUS, Modbus
or analog signals, and supports smart
lamp control, safety and servicing
options.
Technology:
All ELC® are based on a high
frequency resonant power converter to
precisely power the medium pressure
lamps. This topology combines highest
efficiency at lowest electromagnetic
interference. The fully insulated lamp
output allows perfect lamp matching as
well as short circuit and earth fault
resistant operation.
Our MP lamps:
Our customer-specific in-house lamp
development and manufacturing permits
the optimum component match for your
UV system. Coupled with the consistent
quality strategy, we supply the
industries most reliable and efficient UV
components available on the UV-
market.
� system reliability- smart soft ignition
- highest lamp lifetime
� efficiency
- low heat exhaust - highest ambient temperature
- energy savings
� step less lamp control - dimming range 20% - 100%
- precisely controlled and monitored lamp status
� mains compliance- high power factor- low harmonic distortion
- symmetric load- no inrush current
- no start-up over-current
� safety features
- insulated lamp output- integrated earth fault detection- short circuit proof
ELC® is a registered trademark of IST Metz GmbH
![Page 3: Flyer ELC 2015 · 2019. 6. 29. · control port PROFIBUS harmonic current distortion THDi 33% efficiency typ. 96% mains voltage 400 V or 480 V, ... Lamp feeder connection mains connection](https://reader035.vdocuments.us/reader035/viewer/2022071011/5fc8f9a1bac9456057776ba7/html5/thumbnails/3.jpg)
2/1
9/2
015
3
ELC® N series
• nominal lamp power: 4 kW to 32 kW
• analog / digital PLC control port
• highest efficiency
• protection IP 20
• air cooled
ELC® P series
• nominal lamp power: 5 kW to 35 kW
• PROFIBUS control
• highest efficiency
• protection IP 20
• air cooled
ELC® X series
• lamp power: 6 kW, 8 kW, 4kW, 12kW*
• Modbus and PROFIBUS control
• wide input voltage range 360 V to 528 V
• lowest harmonic distortion THDi
• protection IP 66
• integrated heat exchange
• X_B series option for marine applications
ELC® IP series
• nominal lamp power: 5 kW to 10 kW
• field bus (PROFIBUS) control
• protection IP 65
• water cooled
ELC® series
* 12kW under development
![Page 4: Flyer ELC 2015 · 2019. 6. 29. · control port PROFIBUS harmonic current distortion THDi 33% efficiency typ. 96% mains voltage 400 V or 480 V, ... Lamp feeder connection mains connection](https://reader035.vdocuments.us/reader035/viewer/2022071011/5fc8f9a1bac9456057776ba7/html5/thumbnails/4.jpg)
2/1
9/2
015
4
ELC® X series
CE, EN 50 178, (UL and IMO under development)*approvals
built-in safety relay for emergency stopsafety interrupt
45 °C (X_B series 55°C)max. ambient temperature
voltage, current, power, statuslamp monitoring
470mm x 125 mm (w x h)
depth: X4: 260mm, X6: 320mm, X8: 420mm, X12: 420mm
dimensions
X6: 14 kg, X8: 19 kg *weight
stacking option allows cabinet-free installation of up to 12
modules in one tower
special feature
standardearth fault detection
40m (standard), (100m with special lamp cable)*max. distance to lamp
IP66protection
forced air cooling, no air filter requiredcooling
typ. 0.98power factor
16% to 100%*lamp dimming range
PROFIBUS and Modbuscontrol port
< 10%harmonic current distortion THDi
typ. 94%efficiency
wide input range 360V - 528V, 2 phase mains voltage
1100 V
800 V
600 V
400 V
Lamp voltage
Appendix A12 kWELC X12-110*
Appendix A8 kWELC X8-80
Appendix A4 kWELC X4-40
Dimensions seeLamp powerType
6 kW Appendix AELC X6-60
The result of intense in-house R&D and market experience; The X series combines ideal mains compatibility with a highly innovative cooling principle for best reliability and maximum installation flexibility. The field bus allows smart control and in-field diagnostics.
* under development
* preliminary data, subject to technical alterations, data may vary over types
![Page 5: Flyer ELC 2015 · 2019. 6. 29. · control port PROFIBUS harmonic current distortion THDi 33% efficiency typ. 96% mains voltage 400 V or 480 V, ... Lamp feeder connection mains connection](https://reader035.vdocuments.us/reader035/viewer/2022071011/5fc8f9a1bac9456057776ba7/html5/thumbnails/5.jpg)
2/1
9/2
015
5
ELC® X_B series
Appendix A
Appendix A
Appendix A
Appendix A
Dimensions see
1100 V
800 V
600 V
400 V
Lamp voltage
12 kWELC X12B-110*
8 kWELC X8B-80
4 kWELC X4B-40*
Lamp powerType
6 kWELC X6B-60
For marine applications like BWMS; This version of ELC X series is designedin compliance with IMO MEPC174(58) regulation.
* under development
subject to technical alterations, data may vary over types
� max. temperature 55°C
� vibration proof
� humidity proof (IP66 rated design)
� built-in heat exchange
� included harmonic filter optimized for generator supply
� wide supply input 360 to 528 V, fully covers 440V ±20%
� advanced lamp ignition for low temperatures
� lamp distance up to 100m
� highest power density
� designed according to MEPC174(58)
![Page 6: Flyer ELC 2015 · 2019. 6. 29. · control port PROFIBUS harmonic current distortion THDi 33% efficiency typ. 96% mains voltage 400 V or 480 V, ... Lamp feeder connection mains connection](https://reader035.vdocuments.us/reader035/viewer/2022071011/5fc8f9a1bac9456057776ba7/html5/thumbnails/6.jpg)
2/1
9/2
015
6
ELC® P series
CE, EN 50 178approvals
yessafety interrupt
40 °C to 50 °C (depending on ELC type)max. ambient temperature
voltage, current, powerlamp monitoring
see table abovedimensions
typ. 15 kg to 37 kgweight
standardearth fault detection
15 to 40m (depending on ELC type)max. distance ELC® to lamp
IP20protection
forced air coolingcooling
P type: typ. 0.93, PE type: typ. 0.90power factor
20% to 100%lamp dimming range
PROFIBUScontrol port
P type: 33%, PE type: typ. 36% *harmonic current distortion THDi
P type: typ. 96%, PE type: typ. 94%efficiency
400 V or 480 V, ± 10%, 3 phase, 50/60 Hzmains voltage
on request
on request
on request
on request
ELC P10-480-80*
ELC P5HV-480-40
Type
480 V version
Appendix C2200V22 kWELC PE22-400-220
Appendix D800V10 kWELC P10-400-80
Appendix D400V5 kWELC P5HV-400-40
2800V
1400V
1100V
Lamp
voltage
Dimensions
see
Lamp
power
Type
400 V version
32 kW
16 kW
12 kW
Appendix CELC PE32-400-280
Appendix BELC PE16-400-140
Appendix BELC PE12-400-110
Based on the N series, the P series offers a smart digital field bus control combined with highest power density in a compact and efficient design. The field bus control enables in-field diagnostics, and significantly reduces wiring.
subject to technical alterations
* PE type requires additional mains choke UK = 4%
* under development
![Page 7: Flyer ELC 2015 · 2019. 6. 29. · control port PROFIBUS harmonic current distortion THDi 33% efficiency typ. 96% mains voltage 400 V or 480 V, ... Lamp feeder connection mains connection](https://reader035.vdocuments.us/reader035/viewer/2022071011/5fc8f9a1bac9456057776ba7/html5/thumbnails/7.jpg)
2/1
9/2
015
7
ELC® N series
CE, EN 50 178, (UL depending on ELC type)approvals
nosafety interrupt
40 °C to 50 °c (depending on ELC type)max. ambient temperature
current, powerlamp monitoring
see table abovedimensions
typ. 15 kg to 37 kgweight
standardearth fault detection
15 to 40m (depending on ELC type)max. distance ELC® to lamp
IP20protection
forced air coolingcooling
N type: typ. 0.93, NE type: typ. 0.88power factor
20% to 100%lamp dimming range
analog 0-10V, digital I/O, PLC compatiblecontrol port
N type: 33%, NE type: typ. 45% *harmonic current distortion THDi
N type: typ. 96%, NE type: typ. 94% (depending on ELC type)efficiency
400 V or 480 V, ± 10%, 3 phase, 50/60 Hzmains voltage
Appendix D400Vtwo times 4 kWELC N2x4-480-40ELC N2x4-400-40
Appendix D400V4 kWELC N2x4-480-40ELC N4HV-400-40
on request
on request
on request
on request
ELC N10-480-80
ELC N8-480-80
ELC N6-480-75
ELC N5HV-480-40
ELC N3HV-480-30
Type
480 V version
Appendix C2200V22 kWELC NE22-400-220
Appendix D800V10 kWELC N10-400-80
Appendix D800V8 kWELC N8-400-80
Appendix D750V6 kWELC N6-400-75
Appendix D400V5 kWELC N5HV-400-40
Appendix D300V3 kWELC N3HV-400-30
2800V
1400V
1100V
Lamp
voltage
Dimensions
see
Lamp
power
Type
400 V version
32 kW
16 kW
12 kW
Appendix CELC NE32-400-280
Appendix BELC NE16-400-140
Appendix BELC NE12-400-110
A modular ELC® concept offering the highest efficiency and process stability for all applications. The analog control port offers easy connection to any PLC.
subject to technical alterations * NE type requires additional mains choke UK = 4%
![Page 8: Flyer ELC 2015 · 2019. 6. 29. · control port PROFIBUS harmonic current distortion THDi 33% efficiency typ. 96% mains voltage 400 V or 480 V, ... Lamp feeder connection mains connection](https://reader035.vdocuments.us/reader035/viewer/2022071011/5fc8f9a1bac9456057776ba7/html5/thumbnails/8.jpg)
2/1
9/2
015
8
ELC® IP series
CE, EN 50 178approvals
standardsafety interrupt
35 °C max. water temperature
voltage, current, powerlamp monitoring
approx. 540 x 130 x 235 mm (h x w x d)dimensions
approx. 15 kgweight
standardearth fault detection
15 to 20m (depending on ELC type)max. distance ELC® to lamp
IP65protection
water 3L / mincooling
typ. 0.93power factor
20% to 100%lamp dimming range
PROFIBUScontrol port
33%harmonic current distortion THDi
typ. 96%efficiency
400 V or 480 V, 3 phase , ± 10%, 50/60 Hzmains voltage
ELC P10IP-480-80*
ELC P5IP-480-40*
Type
480 V version
800V10 kWELC P10IP-400-80
400V5 kWELC P5IP-400-40*
Lamp
voltage
Lamp
power
Type
400 V version
Perfectly protected water-cooled ELC® for harsh operating conditions. This series is controlled via PROFIBUS, allowing smart control and in-field diagnostics.
subject to technical alterations
* on request
![Page 9: Flyer ELC 2015 · 2019. 6. 29. · control port PROFIBUS harmonic current distortion THDi 33% efficiency typ. 96% mains voltage 400 V or 480 V, ... Lamp feeder connection mains connection](https://reader035.vdocuments.us/reader035/viewer/2022071011/5fc8f9a1bac9456057776ba7/html5/thumbnails/9.jpg)
2/1
9/2
015
9
Appendix A: ELC® X series
ELC® X4
ELC® X6
ELC® X8, X12
![Page 10: Flyer ELC 2015 · 2019. 6. 29. · control port PROFIBUS harmonic current distortion THDi 33% efficiency typ. 96% mains voltage 400 V or 480 V, ... Lamp feeder connection mains connection](https://reader035.vdocuments.us/reader035/viewer/2022071011/5fc8f9a1bac9456057776ba7/html5/thumbnails/10.jpg)
2/1
9/2
015
10
Appendix B: ELC® NE12, NE16, PE12 , PE16
501 m
m
min
. 150
540 m
m
31 mm 31 mm
650 m
m
200 mm
Obentop
min
. 150
261 mm
263,5
mm
control connector
Lampenstecker lampconnection
Netzanschlußline input
Luftaustrittair exhaust
Steckerleiste für Steuersignale
Lufteintrittair entrance
![Page 11: Flyer ELC 2015 · 2019. 6. 29. · control port PROFIBUS harmonic current distortion THDi 33% efficiency typ. 96% mains voltage 400 V or 480 V, ... Lamp feeder connection mains connection](https://reader035.vdocuments.us/reader035/viewer/2022071011/5fc8f9a1bac9456057776ba7/html5/thumbnails/11.jpg)
2/1
9/2
015
11
501 m
m
min
. 150
540 m
m
31 mm 31 mm
650 m
m
200 mm
Obentop
min
. 150
261 mm
control connector
Lampenstecker lampconnection
Netzanschlußline input
Luftaustrittair exhaust
Steckerleiste für Steuersignale
Lufteintrittair entrance
484 m
m
Lufteintrittair entrance
Luftaustrittair exhaust
Appendix C: ELC® NE22, NE32, PE22, PE32
![Page 12: Flyer ELC 2015 · 2019. 6. 29. · control port PROFIBUS harmonic current distortion THDi 33% efficiency typ. 96% mains voltage 400 V or 480 V, ... Lamp feeder connection mains connection](https://reader035.vdocuments.us/reader035/viewer/2022071011/5fc8f9a1bac9456057776ba7/html5/thumbnails/12.jpg)
2/1
9/2
015
12
Appendix D: ELC® N3 to N10, P5 to P10
Back mounting(see manual for further info)
Side-by-side rack mounting(see manual for further info)
321 mm
130 m
m
min
. 20
min
. 50
top
473 m
m
min
. 100
min
. 100
520 m
m
539 m
m
80 mm23 mm
M8 (4x)
Lamp feeder connection
mains connection
pin-and-socket connectorfor control signals