flowpath control ex50li - frsa · 2018. 8. 20. · flowpath™ control shoulder strap integrated...

1
Rehabilitation Quickly cool and rehabilitate with integrated misters. PowerStream® External Battery Charger Charge batteries on fire apparatus Order # R2C-5500DC Charge batteries at fire station Order # R2C-5500AC230 Swappable 40V Li-Ion Battery Pack Spare Battery (recommend ordering 2) Order # R2-360-AH-U Stay Unplugged, Indefinitely! Swappable battery packs with enhanced IP66 water jet protection to protect against the inevitable sweep of the fire hose. The ability to have extra packs ready to go removes the limitations of other battery fan concepts, leading towards full corded fan replacement on the fire ground. 40V Lithium Ion Battery Packs Advanced, High Energy Density 432 Wh Lithium Ion battery system was designed specifically for the high draw and sustained run-time applications demanded of PPV fans. Available Accessories Operational Flexibility 090617 Convert to Confined Space Rescue Fan Duct Adapter/Reducer Order # EL2211 40cm duct (4.6m length) Order # FDT-1615BR 40cm duct (7.6m length) Order # FDT-1625BR Convert to a Smoke Ejector Door Bar and Hangar Kit Order # EL7095K Hanger Kit (if you already own door bar) Order # EL8095 Model EX50Li Order# EL5500AUS (Batteries not included) Motor 0.8 Hp / 0.6 kW Runtime @ Max. Speed DC: 90 minutes (four battery packs) DC: 45 minutes (two battery packs) DC: 23 minutes (one battery pack) AC: Unlimited Battery System 40V Lithium-ion, 432Wh, 12Ah Electric Power Plug 230V, Type I, AS-3112 IP Rating (Motor/Battery System/ Controller) IP66 / IP66 / IP66 Dimensions (h/w/d) 56 x 53 x 30 cm Weight with two batteries: 25 kg with one battery: 23 kg without batteries: 20 kg Approvals AMCA AMCA Verified Airflow Single Door Opening 15,187 m 3 /hr Lightweight, Aircraft Grade Aluminum Alloy Frame Specifications AMCA 240, as defined and tested by the third-party Air Movement and Control Association (AMCA), is tested through a standard area opening which represents a single-door structure opening most often used in fire fighting PPV operations. This test procedure is published and is the most accurate method for PPV airflow testing that currently exists. AMCA’s testing center is available to all manufacturers of ventilators for performance verification to this standard. Due to its standardized, published testing procedure and third-party status, this is known internationally as the best testing method for comparing PPV fans. Verify performance data online at AMCA.org. Note: Output changes as setback from the opening changes. Single door airflow is per AMCA 240-15 testing. This data derives from 0” static pressure. Real world results will be substantially reduced by structure backpressure. The EX50Li tested at 14 ft (4.3 m) setback at 13° tilt and 2798 rpm. 46 cm All-Purpose Battery Ventilator EX50Li Swappable 40V Li-Ion Battery Pack Door Bar & Hanger Kit Duct Adapter & Standard Duct Battery Charger PPV Equipped with 2nd generation PowerStream ® airflow straighteners for flexible positioning, reduced noise inside the structure and a deeper FlowPath™ through the structure. Confined Space Rescue Used directly on top of a manhole or connected to duct for rescues in a confined space. Smoke Ejector Perfectly balanced to hang from a doorbar during smoke ejection. WWW.FRSA.COM.AU Vehicle Mount Kit Custom mount that perfectly fits fan Order # EL600K Vehicle Mount Kit EX50Li Mister EX50Li Mister Order # EL8111 Shoulder Strap Order # EL6013 FlowPath Control Shoulder Strap Integrated LED Flood Lights illuminate the entry point of a structure during night operations Euramco Brushless DC Motor IP66 Water Resistance Protects from Powerful Water Jets Swappable 40V Li-Ion Battery Packs can be Charged in 4 hrs Next generation Intellisense™ E2 Controller Equipped with 2nd Generation PowerStream ® Air Straighteners Optional Integrated Misters Wide range tilt adjustment

Upload: others

Post on 10-Sep-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FlowPath Control EX50Li - FRSA · 2018. 8. 20. · FlowPath™ Control Shoulder Strap Integrated LED Flood Lights illuminate the entry point of a structure during night operations

RehabilitationQuickly cool and rehabilitate with integrated misters.

PowerStream®

External Battery ChargerCharge batteries on fire apparatus Order # R2C-5500DCCharge batteries at fire stationOrder # R2C-5500AC230

Swappable 40V Li-Ion Battery PackSpare Battery (recommend ordering 2)Order # R2-360-AH-U

Stay Unplugged, Indefinitely! Swappable battery packs with enhanced IP66 water jet protection to protect against the inevitable sweep of the fire hose. The ability to have extra packs ready to go removes the limitations of other battery fan concepts, leading towards full corded fan replacement on the fire ground.

40V Lithium Ion Battery Packs Advanced, High Energy Density 432 Wh Lithium Ion battery system was designed specifically for the high draw and sustained run-time applications demanded of PPV fans.

Available AccessoriesOperational Flexibility

0906

17

Convert to Confined Space Rescue FanDuct Adapter/Reducer Order # EL221140cm duct (4.6m length) Order # FDT-1615BR40cm duct (7.6m length) Order # FDT-1625BR

Convert to a Smoke EjectorDoor Bar and Hangar KitOrder # EL7095KHanger Kit (if you already own door bar)Order # EL8095

Model EX50Li

Order# EL5500AUS (Batteries not included)

Motor 0.8 Hp / 0.6 kW

Runtime @ Max. Speed

DC: 90 minutes (four battery packs)DC: 45 minutes (two battery packs)DC: 23 minutes (one battery pack)AC: Unlimited

Battery System 40V Lithium-ion, 432Wh, 12Ah

Electric Power Plug 230V, Type I, AS-3112

IP Rating (Motor/Battery System/ Controller)

IP66 / IP66 / IP66

Dimensions (h/w/d) 56 x 53 x 30 cm

Weightwith two batteries: 25 kgwith one battery: 23 kgwithout batteries: 20 kg

Approvals AMCA

AMCA Verified Airflow

Single Door Opening 15,187 m3/hr

Lightweight, Aircraft Grade Aluminum Alloy Frame

Specifications

AMCA 240, as defined and tested by the third-party Air Movement and Control Association (AMCA), is tested through a standard area opening which represents a single-door structure opening most often used in fire fighting PPV operations. This test procedure is published and is the most accurate method for PPV airflow testing that currently exists. AMCA’s testing center is available to all manufacturers of ventilators for performance verification to this standard. Due to its standardized, published testing procedure and third-party status, this is known internationally as the best testing method for comparing PPV fans. Verify performance data online at AMCA.org.

Note: Output changes as setback from the opening changes. Single door airflow is per AMCA 240-15 testing. This data derives from 0” static pressure. Real world results will be substantially reduced by structure backpressure. The EX50Li tested at 14 ft (4.3 m) setback at 13° tilt and 2798 rpm.

46 cmAll-Purpose Battery Ventilator

EX50Li

Swappable 40V Li-Ion Battery Pack

Door Bar & Hanger Kit

Duct Adapter & Standard Duct

Battery Charger

PPVEquipped with 2nd generation PowerStream® airflow

straighteners for flexible positioning, reduced noise inside the structure and a deeper FlowPath™ through the structure.

Confined Space RescueUsed directly on top of a manhole or connected to

duct for rescues in a confined space.

Smoke EjectorPerfectly balanced to hang from

a doorbar during smoke ejection.

WWW.FRSA.COM.AU

Vehicle Mount KitCustom mount that perfectly fits fanOrder # EL600K

Vehicle Mount Kit EX50Li MisterEX50Li MisterOrder # EL8111

Shoulder StrapOrder # EL6013

FlowPath™ Control

Shoulder Strap

Integrated LED Flood Lights illuminate the entry point of a

structure during night operations

Euramco Brushless DC Motor

IP66 Water Resistance Protects from Powerful Water Jets

Swappable 40V Li-Ion Battery Packs can be Charged in 4 hrs

Next generation Intellisense™ E2 Controller

Equipped with 2nd Generation PowerStream® Air Straighteners

Optional Integrated Misters

Wide range tiltadjustment