flow divider applicationssmittechae.com/assets/pdf/4_scherzinger/2_flow_divider... · 2020. 8....

4
Scherzinger Pump Technology I Bregstr. 23-25 I D-78120 Furtwangen I Phone: +49 (0) 7723 / 6506-0 I Fax: +49 (0) 7723 / 6506-40 I E-Mail: [email protected] I ©2014 by Scherzinger Pump Technology I Doc# C4-1122139, dt. 21.05.2014 Flow Divider Applications GE Frame Flow Divider Features Picture Frame 5 / 6 Type: No. of elements: Fuel Application: Rated flow capacity: Option(s): Linear 10 various 34GPM (128 l/min) - Additional AC or DC starter motor, - TINOX* Frame 6B Type: No. of elements: Application: Rated flow capacity: Option(s): Linear 10 Distillate 83GPM (316 l/min) - AC or DC motor, - Magnetic Pick Ups - TINOX Frame 6C Type: No. of elements: Fuel Application: Rated flow capacity: Option(s): Linear 6 Distillate 119GPM (450 l/min) - AC motor, - Magnetic Pick Ups - TINOX Frame 7EA Type: No. of elements: Fuel Application: Rated flow capacity: Option(s): Circular 10 various 160GPM (605 l/min) - NPT or SAE outlets - With SST inlet flange, - Economy version

Upload: others

Post on 18-Jan-2021

2 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Flow Divider Applicationssmittechae.com/assets/PDF/4_SCHERZINGER/2_Flow_Divider... · 2020. 8. 18. · Flow Divider Applications GE Frame Flow Divider Features Picture Frame 5 / 6

Scherzinger Pump Technology I Bregstr. 23-25 I D-78120 Furtwangen I Phone: +49 (0) 7723 / 6506-0 I Fax: +49 (0) 7723 / 6506-40 I E-Mail: [email protected] I ©2014 by Scherzinger Pump Technology I Doc# C4-1122139, dt. 21.05.2014

Flow Divider Applications GE Frame Flow Divider Features Picture Frame 5 / 6 Type:

No. of elements: Fuel Application: Rated flow capacity: Option(s):

Linear 10 various 34GPM (128 l/min) - Additional AC or DC

starter motor, - TINOX*

Frame 6B Type: No. of elements: Application: Rated flow capacity: Option(s):

Linear 10 Distillate 83GPM (316 l/min) - AC or DC motor, - Magnetic Pick Ups - TINOX

Frame 6C Type: No. of elements: Fuel Application: Rated flow capacity: Option(s):

Linear 6 Distillate 119GPM (450 l/min) - AC motor, - Magnetic Pick Ups - TINOX

Frame 7EA Type: No. of elements: Fuel Application: Rated flow capacity: Option(s):

Circular 10 various 160GPM (605 l/min) - NPT or SAE outlets - With SST inlet flange, - Economy version

Page 2: Flow Divider Applicationssmittechae.com/assets/PDF/4_SCHERZINGER/2_Flow_Divider... · 2020. 8. 18. · Flow Divider Applications GE Frame Flow Divider Features Picture Frame 5 / 6

Scherzinger Pump Technology I Bregstr. 23-25 I D-78120 Furtwangen I Phone: +49 (0) 7723 / 6506-0 I Fax: +49 (0) 7723 / 6506-40 I E-Mail: [email protected] I ©2014 by Scherzinger Pump Technology I Doc# C4-1122139, dt. 21.05.2014

Frame 7FA Type: No. of elements: Fuel Application: Rated flow capacity: Option(s):

Linear 14 various 266GPM (1050 l/min) - TINOX

Frame 9E Type:

No. of elements: Fuel Application: Rated flow capacity: Option(s):

Circular 14 various 168GPM (636 l/min) - Additional AC or DC

starter motor

Type:

No. of elements: Fuel Application: Rated flow capacity: Option(s):

Linear 14 various 229GPM (867 l/min) - AC starter motor - Magnetic Pick Ups - TINOX

Frame 9FA/9FB Type: No. of elements: Fuel Application: Rated flow capacity: Option(s):

Circular 18 various 356GPM (1350 l/min) - Additional AC starter

motor

Type: No. of elements: Fuel Application: Rated flow capacity: Option(s):

Linear 18 various 356GPM (1350 l/min) - TINOX

Page 3: Flow Divider Applicationssmittechae.com/assets/PDF/4_SCHERZINGER/2_Flow_Divider... · 2020. 8. 18. · Flow Divider Applications GE Frame Flow Divider Features Picture Frame 5 / 6

Scherzinger Pump Technology I Bregstr. 23-25 I D-78120 Furtwangen I Phone: +49 (0) 7723 / 6506-0 I Fax: +49 (0) 7723 / 6506-40 I E-Mail: [email protected] I ©2014 by Scherzinger Pump Technology I Doc# C4-1122139, dt. 21.05.2014

BHEL Flow Divider Features Picture Frame 6B Type:

No. of elements: Fuel Application: Rated flow capacity: Option(s):

Circular 10 Various 80GPM (303 l/min)

Westinghouse Flow Divider Features Picture W501 Type:

No. of elements: Fuel Application: Rated flow capacity: Option(s):

Linear 14 Various 189GPM (716 l/min) - Motor position

W501 Type: No. of elements: Application: Rated flow capacity: Option(s):

Linear 16 Various 140GPM (530 l/min) - Motor position

Siemens Flow Divider Features Picture SGT6-5000F5/6 Type:

No. of elements: Application: Rated flow capacity: Option(s):

Linear 16 Pilot Stage 42,5GPM (161 l/min) TINOX

Type: No. of elements: Application: Rated flow capacity: Option(s):

Linear 16 Stage A/B 157GPM (595 l/min) - TINOX

Page 4: Flow Divider Applicationssmittechae.com/assets/PDF/4_SCHERZINGER/2_Flow_Divider... · 2020. 8. 18. · Flow Divider Applications GE Frame Flow Divider Features Picture Frame 5 / 6

Scherzinger Pump Technology I Bregstr. 23-25 I D-78120 Furtwangen I Phone: +49 (0) 7723 / 6506-0 I Fax: +49 (0) 7723 / 6506-40 I E-Mail: [email protected] I ©2014 by Scherzinger Pump Technology I Doc# C4-1122139, dt. 21.05.2014

SGT6-5000F(LC) Type: No. of elements: Application: Rated flow capacity: Option(s):

Linear 16 Main Stage 251GPM (952 l/min) - TINOX

SGT5-8000H Type: No. of elements: Application: Rated flow capacity: Option(s):

Linear 16 Pilot Stage 65,4GPM (247,8 l/min) - TINOX

Type: No. of elements: Application: Rated flow capacity: Option(s):

Linear 16 Stage A/B 260GPM (986 l/min) - TINOX

SGT6-8000H Type: No. of elements: Application: Rated flow capacity: Option(s):

Linear 12 Pilot Stage 64GPM (242,4 l/min) - TINOX

Type: No. of elements: Application: Rated flow capacity: Option(s):

Linear 12 Stage A/B 192GPM (728 l/min) TINOX

Notes:

- Technical details / Data sheets upon request - Subject to technical changes - *TINOX = completely out of non corrosive materials