floating suctions – c0001-c0013, c0015, c0093 ... - … · emco wheaton floating suctions...
TRANSCRIPT
INSIDE
Fluid Transfer Division
Floating suctions – C0001-C0013, C0015, C0093
C00
01-C
0013
, C00
15, C
0093
EMCO WHEATON floating suctions
Design:
• variousdesigns,dependingonthetankdimensionsandinletposition
• sizes:2“to24“
• theproductisalwaysistransferredwithinadefineddistanceundertheliquidlevel
• contaminationdirt /sedi-ments/solidparticlesandheavyfluidsremainsepara-tedonthetankbottom
• constantproductqualityindependentfromliquidlevel
• longlifetimeandlowwearcharacteristicsduetosplittflangeballbearingswiveljoints
• easyinstallationviainternalswiveljointflanging
• highpressureratingforbothinternalandexternal(pres-surevariations)
• vortexpreventionthroughoptimalinletdesign
• pressure-prooffloats
Floating suctions compared with per-manently fixed nozzles have the follo-wing advantages:
EMCOWHEATONUSAINC9111JackrabbitRoad·Houston,Texas77095·USA
Phone+1281856-1300·Fax+1281856-1325www.emcowheaton.com·[email protected]
Whilst the content of this leaflet has been edited with the greatest care, we are not liable for any errors and/or omissions. Subject to change without notice.
ISO9001
Materials and technical data
C00
01-C
0013
,C00
15,C
0093
US
A0
7/06
Dimensions and technical data
Floating suctions – C0001-C0013, C0015, C0093
EMCO WHEATON floating suction for any container/tankFor use in semi-buried tankage with lateral outlet on the centre-line
C0001 right hand design C0002 left hand design C0003 centre design
single arm
For use in buried tankage with the outlet through the manhole
C0004 connection at Pos. I C0005 connection at Pos. II C0006 connection at in Pos. III C0007 connection at Pos. IV C0008 connection at Pos. V
single arm
For use in above ground tankage with lateral outlet near the bottom
C0009 right hand design C0010 left hand design C0011 centre design at Pos. V
single arm
For use in vertical storage tanks with lateral outlet near the bottom
C0012 left hand design
C0013 left hand design
double arm
triple arm
The tank diameter must be bigger than the maximum fluid level.
At fluid levels bigger than the tank diameter double or triple arm floating suctions may be required depending on the relation between ∅ and height.
For articulated drainage units with floating ceiling/floating roof
C0015 left hand design „hanging“two-pieces
The loads resulting from the weight of the floating suction must be absorbed by the floating ceiling/roof.
For articulated drainage units with floating ceiling/floating roof
C0093 right hand design with rollsingle arm
Tank roof design must absorb the force of floating suction.
Aluminum, Steel or Stainless steel
Buna, Viton or PTFE (other seals available)
pressureless
+14 °F up to +125 °F
materials of product carrying parts
materials of seals
design pressure
design temperatureAlternativeconfigurationsonrequest.
• Theexactsizeisdependantontherequiredsuctionspeed.Theflowvelocityshouldnotexceed3ft/s.
• Designandlength(s)offloatingsuctionwillbedeterminedbykindoftankconfigurationandallrelevantdimensions.
• Optimisingthedesignofthefloatingsuctionpleasefillinour„datasheetfloatingsuctions“.
• Iftherearenospecialinstruc-tionsthefloatingsuctionwillbedesignedthatallpartscanbeinstalledthroughamanholesize24inch.Thefloatingsuctionwillbedeliveredinparts.
Notes:
Typical floating suction – single armC0009