flexicom-cx-user-157168 (1)

16
Instructions for Use Condensing Boilers/ Flexicom cx 24cx G.C. No. 47-047-33 30cx G.C. No. 47-047-34 35cx G.C. No. 47-047-35

Upload: trinhduong

Post on 30-Dec-2016

223 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: flexicom-cx-user-157168 (1)

Instructions for UseCondensing Boilers/ Flexicom cx

24cx G.C. No. 47-047-3330cx G.C. No. 47-047-3435cx G.C. No. 47-047-35

Page 2: flexicom-cx-user-157168 (1)

READ CAREFULLY BEFORE USING

1 Readme.................................................................................................................. 31.1 Welcome........................................................................................... 31.2 GuaranteePack................................................................................ 31.3 Servicing........................................................................................... 31.4 Benchmark....................................................................................... 41.5 QuickReferenceGuide.................................................................... 4

2 Introducingyourappliance...................................................................................... 52.1 Appliancedescription....................................................................... 52.2 Accessories...................................................................................... 5

3 Productdocumentation........................................................................................... 53.1 Documentstorage............................................................................ 53.2 Explanationofsymbols..................................................................... 5

4 Safety...................................................................................................................... 64.1 Whattodoifyousmellgas............................................................. 64.2 Safetyrecommendations.................................................................. 64.3 Safetyregulations............................................................................. 6

5 GuaranteeResponsibility........................................................................... 85.1 DetailedGuarantee.......................................................................... 85.2 ApplianceUse/Manufacturerresponsibility.................................... 8

6 Recycling................................................................................................................. 96.1 Appliance.......................................................................................... 96.2 Packaging......................................................................................... 9

7 Clearances.............................................................................................................. 9

HOW TO USE YOUR APPLIANCE

8 Overview............................................................................................................... 108.1 DisplayDescription......................................................................... 108.2 SwitchingOnandOff...................................................................... 10

ANY ASSISTANCE?

9 FaultFinding..........................................................................................................119.1 Electricalsupplyfailure....................................................................119.2 Appliancefailstolight......................................................................11

10 Appliancesafetydevices....................................................................................... 1210.1 BoilerShutdown............................................................................. 1210.2 Protectingagainstfrost................................................................... 1210.3 CondensateDrainBlockage........................................................... 1210.4 SafetyDischargeValve.................................................................. 14

11 Appliancemaintenanceandservicing................................................................... 1411.1 Cleaning......................................................................................... 1411.2 Regularservicing.............................................................................1411.3 SealedWaterSystems.....................................................................1411.4 SpareParts.....................................................................................14

12 TipsforSavingEnergy.......................................................................................... 1513 Contactyourafter-salesorganisation................................................................... 15

table of contents

- 2 -

Page 3: flexicom-cx-user-157168 (1)

0020127401_00 - 06/11 - Glow-worm

READ CAREFULLY BEFORE USING

- 3 -

READ CAREFULLY BEFORE USING

1 Read me

1.1 Welcome

Theseinstructionsareanintegralpartoftheboilerandmust,tocomplywiththecurrentissueoftheGasSafety(InstallationandUse)Regulations,beleftwiththeuser.

EnsurethattheinstallerhasfullycompletedtheBenchmarkChecklistlocatedontheinsidebackpagesoftheinstallationinstructionssuppliedwiththeproductandthatyouhavesignedittosaythatyouhavereceivedafullandclearexplanationofitsoperation.TheinstallerislegallyrequiredtocompleteacommissioningchecklistasameansofcomplyingwiththeappropriateBuildingRegulations(EnglandandWales).

AllinstallationsmustbenotifiedtoLocalAreaBuildingControleitherdirectlyorthroughaCompetentPersonsScheme.ABuildingRegulationsComplianceCertificatewillthenbeissuedtothecustomerwhoshould,onreceipt,writetheNotificationNumberontheBenchmarkChecklist.

Readtheseinstructionsandfollowthemcarefullyforthesafeandeconomicaluseofyourboiler.

Do not forget to read the chapters “Safety” and “Guarantee” where you will find important information for your safety.

1.2 Guarantee Pack

Thepackcontainstheletterofintroductionandtheguarantee.Theextendedguaranteeissuppliedlooseandwerecommendthatyoushouldreadit.

Completeandreturnassoonaspossibleyourguaranteeregistrationcard.

IfyourguaranteeregistrationcardismissingyoucanobtainacopyorrecordyourregistrationbytelephoningtheGlow-wormCustomerServicenumber08000732142.

1.3 Servicing

Thisproductshouldbeservicedregularlytooptimiseitssafety,efficiencyandperformance.TheserviceengineershouldcompletetherelevantServiceRecordontheBenchmarkChecklistaftereachservice.TheBenchmarkChecklistmayberequiredintheeventofanywarrantyworkandassupportingdocumentationrelatingtohomeimprovementsintheoptionaldocumentssectionoftheHomeInformationPack.

Toensurethecontinuedefficientandsafeoperationoftheboileritisrecommendedthatitischeckedandservicedatregularintervals.Thefrequencyofservicingwilldependuponthesiteconditionsandusage,butingeneral,onceayearshouldbeenough.

Toobtainservice,callyourinstallerorGlow-worm’sownserviceorganisationusingthetelephonenumberontheinsidebackcoverofthisbooklet.

Page 4: flexicom-cx-user-157168 (1)

0020127401_00 - 06/11 - Glow-worm

READ CAREFULLY BEFORE USING

- 4 -

1.4 Benchmark

Glow-wormisalicensedmemberoftheBenchmarkSchemewhichaimstoimprovethestandardsofinstallationandcommissioningofdomesticheatingandhotwatersystemsintheUKandtoencourageregularservicingtooptimisesafety,efficiencyandperformance.

1.5 Quick reference guide

WedesignedthisQuickreferenceguidesothatyoucanstartusingyourappliancerightaway.

ThisQuickreferenceguideassumesthattheappliancehasbeeninstalledandcommissionedbyacompetentperson.

BenchmarkismanagedandpromotedbytheHeatingandHotwaterIndustryCouncil.

• Formoreinformationvisitwww.centralheating.co.uk

MODE

MODE

Page 5: flexicom-cx-user-157168 (1)

0020127401_00 - 06/11 - Glow-worm

READ CAREFULLY BEFORE USING

- 5 -

2 Introducing your appliance

2.1 Appliance description

TheFlexicomcxrangeofboilersaredesignedforuseaspartofasealedwatercentralheatingsystemwithfullypumpedcirculation.Thepump,expansionvesselandassociatedsafetydevicesareallfittedwithintheboiler.

Thedomestichotwaterisdelivereddirectlytothetapwithouttheneedforstorage.

Oncethecontrolsareset,theboileroperatesautomatically.

IntelligentcontrolsareavailableasaccessoriesfromGlow-worm.

ContactyourInstallerorGlow-wormsalesforfurtherinformation.

TheFlexicomcxboilerisanappliancethatusescondensingtechnology,whichrecoversheatfromthefluegases,thisoperatingprinciple,consumeslessenergyandcontributestothereductionofyourhouseholdCO2emissions.

Thisapplianceisaroom-sealedtypeequippedwithafluesystemforairsupplyandtheremovalofcombustionproducts.Thisfluesystemoffersthepossibilitytoinstalltheapplianceinanyroomwithouttheneedforadditionalventilation.

Installationandcommissioningoftheapplianceshouldonlybecarriedoutbyacompetentperson.Theyareresponsiblefortheinstallationandthecommissioninginaccordancewithstandardsinforce.

Youshouldalsoconsultacompetentpersonformaintenanceandrepairoftheapplianceaswellasforanyadjustmentnecessary.

2.2 Accessories

TheFlexicomcxiscompatiblewithmostmakesof230Vprogrammableroomthermostats.

ForincreasedsystemcompatibilityandincreasedenergysavingwithintelligentcontrolGlow-wormofferarangeofcontrolsdedicatedtoworkusingauniquecommunicationsystem-eBus(lowvoltage).

Forfurtherdetailscontactyourinstaller.

3 Product documentation

3.1 Document storage

• Makesurethatthismanualisstoredclosetoyourapplianceforfuturereference.Shouldyoumovehomeensurethatthismanualishandedovertothenewhomeowners.

• Readtheseinstructionsandfollowthemcarefullyforthesafeandefficientuseofyourappliance.

Noresponsibilityorliabilitycanbeacceptedfordamagescausedbyfailuretofollowtheinstructionsinthismanual.

3.2 Explanation of symbols

DANGER: Risk of injuries.

ATTENTION: Risk of damage to the appliance or to its surroundings.

IMPORTANT INFORMATION

Page 6: flexicom-cx-user-157168 (1)

0020127401_00 - 06/11 - Glow-worm

READ CAREFULLY BEFORE USING

- 6 -

4 Safety

4.1 What to do if you smell gas?

- isolateyourgassupplyatthegasemergencycontrolvalve.

- Eliminateallsourcesofignition,i.e.smoking,blowlamps,hotairgunsetc.

- donotoperateelectricallightsorswitches,eitheronoroff.Openalldoorsandwindows,ventilatethearea.

- openimmediatelywindowsanddoorsinordertoventilatetheproperty.

- donotsearchforgasleakswithanakedflame.

- callyourgassupplier’semergencyphonenumber.

- alertotherbuildingoccupants.

4.2 Safety recommendations

Youmustcomplywiththefollowingrecommendationsandsafetyinstructions:

• Neverperformanymaintenanceorrepairoftheapplianceyourself.Onlycompetentpersonsareallowedtoworkontheappliance.

• Nevertamperwithsafetydevices.

• Donotattempttomodifytheapplianceoritsimmediatesurroundingsasthismayaffectonthesafeuseoftheappliance.

• Undernocircumstancesmusttheuserinterferewithoradjustsealedparts.

• Donotallowchildrentooperatetheappliance.

• Donotobstructthefluesystem

Certainhomeimprovementsmayadverselyaffecttheoperationofyour

appliance–youshouldconsultyourinstallerforadvicebeforecarryingoutanywork.

• Donotexposetheappliancetohighhumidity.

• Donotuseorstoreexplosiveorinflammablematerials(e.g.petrol,aerosols,solvents,chlorinebaseddetergents,paint,glueetc.)inthesameroom,compartmentorcupboardastheappliance.Undercertainconditions,thesesubstancescanprovetobecorrosive.

• Donottouchtheheatedsurfacesoftheappliance,suchasoutletduct,hydraulicconnections,alsoaftertheapplianceoperationbecause,foracertaintime,thesesurfacesmaybecomehot.Anycontactwiththemcancauseburns.

Thisappliancecontainsmetalparts(components)andcareshouldbetakenwhenhandlingandcleaning,withparticularregardtoedges.

• Inthecaseofanywaterleak,immediatelyturnoffthecoldwatersupplytotheapplianceandhavetheleakrepairedbyyourcompetentperson.

• Donotstoreorplacearticlesontheappliance.

4.3 Safety regulations

Servicing/maintenanceshouldbecarriedoutbyacompetent personapprovedatthetimebytheHealthandSafetyExecutive,inaccordancewiththerulesinforceinthecountriesofdestination.

IfthisboilerisinstalledinarentedpropertyintheUKthereisadutyofcareimposedontheownerofthepropertybythecurrentissueoftheGasSafety(InstallationandUse)Regulations,Section35.

Page 7: flexicom-cx-user-157168 (1)

0020127401_00 - 06/11 - Glow-worm

READ CAREFULLY BEFORE USING

- 7 -

Gas Safety (Installation and Use) Regulations

Inyourowninterestsandthatofsafety,itistheLawthatALLgasapplianceshavebeeninstalledbyacompetentpersonapprovedatthetimebytheHealthandSafetyExecutive,inaccordancewiththecurrentissueoftheseregulations.

Gas Category

ThisboilerisforuseonlyonG20naturalgas.

Electrical Connection

TheboilerMUSTbeearthed.

TheboilerMUSTbeconnectedtoapermanent230Vac,50Hzsupply,fusedat3A.

Connectionofthewholeelectricalsystemoftheboiler,includinganyheatingcontrols,totheelectricalsupplymustbethroughonecommonisolator.

Thecoloursofthreecoreflexiblecableare,blue-neutral,brown-live,greenandyellow-earth.

Testing and Certification

ThisboileriscertificatedtothecurrentissueofEN483forperformanceandsafety.

Itisimportantthatnoalterationismadetotheboilerunlessapproved,inwriting,byGlow-worm.

AnyalterationnotapprovedbyGlow-worm,couldinvalidatethecertification,boilerwarrantyandmayalsoinfringethecurrentissueofthestatutoryrequirements.

CE Mark

Thisboilermeets therequirementsofStatutoryInstrument,No.3083oftheBoiler(EfficiencyRegulations,andthereforeisdeemedtomeettherequirementsofDirective92/42/EEContheefficiencyrequirementsfornewhotwaterboilersfirewithliquidorgaseousfuels.

TypetestforpurposesofRegulation5certifiedby:Notifiedbody0087.

Product/productioncertifiedby:Notifiedbody0086.

TheCEmarkonthisapplianceshowscompliancewith:

-Directive2009/142/EContheapproximationofthelawsoftheMemberStatesrelatingtoappliancesburninggaseousfuels.

-Directive73/23/EEContheharmonisationoftheLawsoftheMemberStatesrelatingtoelectricalequipmentdesignedforusewithincertainvoltagelimits

-Directive89/336/EEContheapproximationoftheLawsoftheMemberStatesrelatingtoelectromagneticcompatibility.

The CE mark shows that this appliance has been designed according to the safety techniques and rules in force. The compliance of this appliance with the relevant standards has been certified.

Page 8: flexicom-cx-user-157168 (1)

0020127401_00 - 06/11 - Glow-worm

READ CAREFULLY BEFORE USING

- 8 -

5 Guarantee / Responsibility

5.1 Detailed guarantee

ThankyouforinstallinganewGlow-wormapplianceinyourhome.

Glow-wormappliancesaremanufacturedtotheveryhigheststandardsowearepleasedtoofferourcustomersaComprehensiveGuarantee.

Thisproductisguaranteedfor24monthsfromthedateofinstallationor30monthsfromthedateofmanufacture,whicheveristheshorter,forpartsandlabour.

Thesecondyearofthepartsguarantee,fromthebeginningofthe13thmonthonwardsafterinstallationormanufacture,isconditionalupontheboilerhavingbeenservicedbyacompetentpersonapprovedatthetimebytheHealthandSafetyExecutive,inaccordancewiththemanufacturer’srecommendations.Westronglyrecommendregularservicingofyourgasappliance,butwheretheconditionisnotmet,anychargeablesparepartsorcomponentsissuedwithintheapplicableguaranteeperiodstillbenefitfroma12monthwarrantyfromthedateofissuebythemanufacturer.

5.2 Appliance use / manufacturer responsibility

Servicing/maintenanceshouldbecarriedoutbyacompetentperson approvedatthetimebytheHealthandSafetyExecutive,inaccordancewiththerulesinforceinthecountriesofdestination.

Theguaranteeisapplicableontheconditionthat:

- Theapplianceisinstalledbyacompetentpersoninaccordancewithinstallationinstructions.

- Theapplianceisusedfornormaldomesticpurposesandinaccordance

withthemanufacturer’soperatingandmaintenanceinstructions.

- Theapplianceisserviced,maintained,byacompetentperson.

- Therepairorreplacementofpartsduringtheguaranteeperioddoesnothavetheeffectofextendingtheperiod.

Themanufacturerhasnoresponsibilitywhatsoeverforanydamageresultingfrom:

- Anydefectsordamageresultingfromincorrectorpoorinstallation,inadequateservicing,ormaladjustmentofthegasorwaterused.

- Anydefectsinthesystemtowhichtheapplianceisconnected.

- Anydefectscausedbyinadequatefrostprotection.

- Anydeteriorationormaladjustmentfollowingchangesinthenatureorpressureofthegasorthewaterused,orachangeinthecharacteristicsoftheelectricalsupplyvoltage.

• Forfurtherdetails,refertoyourTermsandConditions.

This appliance is intended to be installed only within the designated countries displayed on the type plate.

• Itistheresponsibilityofparents,guardiansandcarers,thattheapplianceisprotectedawayfrompersonsundertheircare.

Page 9: flexicom-cx-user-157168 (1)

0020127401_00 - 06/11 - Glow-worm

READ CAREFULLY BEFORE USING

- 9 -

6 Recycling

ThisappliancecontainsmanyrecyclablepartsandshouldbedisposedofaccordingtothecurrentWEEEregulations.Thepackagingshouldalsobedisposedofaccordingtothecurrentregulations.

6.1 Appliance

TheappliancemustberecycledincompliancewiththeWEEE(WasteElectricalandElectricalEquipment)directivewhich,inparticular,requires:

- selectivecollectionofwasteelectricalandelectronicequipment,

- thesystematicselectiveprocessingofcertaincomponentsandsubstancesdeemeddangerous,

- reuse,recyclingandenergyrecoveryofcollectedWEEE’s.

This symbol indicates that this appliance must not be disposed of with household waste, that it should be selectively collected for energy recovery, reuse or recycling.

• Taketheappliancetoanappropriatecollectionpointforprocessing,energyrecoveryandrecyclingofwasteElectronicandElectricalEquipment.

By complying with this directive, you will contribute to the preservation of natural resources and the protection of human health.

6.2 Packaging

Thecompetentpersonwhoinstalledtheappliancemust:

- sortthewastesoastoseparatethosewhichcanberecycled(cardboard,plastics...)fromthosethatcannot.

- disposeofthewasteincompliancewithregulationsinforce.

7 Clearances

Page 10: flexicom-cx-user-157168 (1)

0020127401_00 - 06/11 - Glow-worm

HOW TO USE YOUR APPLIANCE

- 10 -

HOW TO USE YOUR APPLIANCE

8 Overview

8.1 Display Description

TheUserControlpanelconsistsofthreepushbuttons,aresetbuttonanddisplay,whichwillindicatewithsymbolsthestatusoftheboiler.

8.2 Switching On and Off

Switching on

- Checkthatthewaterandgasisolatingvalvesontheapplianceareopenandthewaterflowsfreelyfromthehotwatertaps,closethetaps.

Do not operate without water

• Makesurethat:

- Theappliancehaselectricalpowerandthereisnodemandfromanyexternalcontrols.

- Thedigitaldisplaywillindicatethesystempressure,whichshouldreadatleast0.7bar(recommended1.0bar).If

thepressureisless,connectthefillingloopandpressuriseasdescribedintheFillingLoopsection9.2.

Switching Off

• Switchofftheelectricalsupply.

- Theapplianceandthedisplaywillshutdown.

If you intend to leave your property empty for a prolonged period, refer to the Appliance Safety Devices section.

8.3 User Controls

If you are in any doubt about the boiler being filled with water contact your installer or Glow-worm's own service organisation using the telephone number shown in the chapter " Contact your after-sales organisation".

• Pressandholdthe"MODE"buttonfor2secondstoenterCentralHeatingfunction,indicatedbyaflashing .

Symbol Mode

Heating+domestichotwater

Heatingonly

Domestichotwateronly

• After5secondsofinactivitythedisplaywillresettoindicatethewatertemperature.

• ToselecttheCentralHeatingtemperature(38-82oC)pressthe"+or-"selectorbuttons.

Page 11: flexicom-cx-user-157168 (1)

0020127401_00 - 06/11 - Glow-worm

HOW TO USE YOUR APPLIANCE

- 11 -

• Theboilerwilloperateautomatically.

• NOTE:ThedisplaywillindicatetheHeatingsystemwatertemperatureorafaultcode(seesectionFaultFinding).

• Thecontrolpanelwillflashanddisplayallitsdigits.Itwillthenreturntothedefaultdisplayanddependingontheselectedoperationandcontrols,displaythetemperaturesettingsandwaterpressure.

Pre heat

ComfortfeaturetomaintaintheDomesticHotWatertemperature,whichimprovestheresponsetimeofhotwateratthetap.ToaccessthePreHeatfunctionholdinthe"+"buttonfor5seconds.Thedisplaywillindicate(flashing)ifitisON/OFF(OF).Pressingthe"-"buttonwillswitchthePreHeatOFFandpressingthe"+"buttonwillswitchitON.After5secondsofinactivitythedisplaywillresettoindicatethewaterpressure.

Switching off - Central Heating mode

• Pressthe"-"selectorbuttontoturnOFFtheCentralHeating.

Alltheappliancefunctionswillbeswitchedoff,exceptfrostprotection.

ANY ASSISTANCE?

9 Fault Finding

Inthissectionfaultcodesthataredisplayed,whichCANbecarriedoutbytheUSERtorestoreapplianceoperation(Correctiveaction:...).OtherfaultcodesMUSTbesolvedbyacompetentpersononly.

Like all condensing boilers it will produce a plume of condensation from the flue terminal in cool weather. This is due to the high efficiency and hence low flue gas temperature of the boiler. It is normal and not a fault indication.

Ifanyfaultpersists,andyourappliancestilldoes not work, leave it switched off andcontactyourcompetentperson.

9.1 Electrical Supply Failure

Theboilerwillnotworkwithoutanelectricalsupplyandnormaloperationoftheboilershouldresumewhentheelectricalsupplyisrestored.Iftheboilerdoesnotresumenormaloperation,checktheexternalcontrols.Itmaybenecessarytorestartyourappliance.

• Torestarttheboiler,presstheresetbutton,seechapter"Howtouseyourappliance►Overview".

9.2 Appliance fails to light

TheLCDwilldisplayaflashing'F'andcodenumber,

• Torestarttheboiler,presstheresetbutton,seechapter"Howtouseyourappliance►Overview".

Page 12: flexicom-cx-user-157168 (1)

0020127401_00 - 06/11 - Glow-worm

HOW TO USE YOUR APPLIANCE

- 12 -

Filling Loop

Connectthefillingloopatthefillingtap.

WiththeCentralHeatingflowisolationvalveopenasindicatedinthediagram.Openthecoldwaterinlettap.Slowlyturnthefillingtapuntilthecorrectpressureisindicatedonthedisplay.

Disconnectthefillingloopatthefillingtap.

Ifthelossofpressureproblempersists,youmustcontactyourInstallation/ServicingcompanyorGlow-wormService.

10 Appliance safety devices

10.1 Boiler Shutdown

Theboilersoftwareisdesignedtorecognisethepotentialforanoverheatlockoutandwillshutdownbeforethishappens.

• Torestarttheboiler,presstheresetbutton,seechapter"Howtouseyourappliance►Overview".

Iftheboilerfailstoresumenormaloperationandallexternalcontrolsarecallingforheat,thencallyourInstallation/ServicingcompanyorGlow-wormservice.

10.2 Protecting against frost

Appliance Protecion

Incaseoftheriskoffrost:

• Makesurethattheelectricalandgassupplytotheapplianceisturnedon.

• Foranabsenceofseveraldays,youcanleavetheappliancetorunnormally.

Theappliancehasabuiltinfrostprotectiondevicethatprotectstheboilerfromfreezing.WiththegasandelectricsuppliesONandirrespectiveofanyroom

thermostatsetting,thefrostprotectiondevicewilloperatethepumpwhenthetemperatureoftheboilerwaterfallsbelow8OC.Atimerisusedsothatthetemperaturecanbecheckedperiodically.After10minutesthepumpwillbestoppedifthetemperatureishigherthan10OCorhasalreadyreached35OC.Theburnerwillactivateiftheboilertemperaturedoesnotreach10OCafter30minutesoratanytimeifthetemperaturedropsto5OC.Theburnerwillswitchoffwhenthetemperaturereaches35OC.

Theappliancealwayshasfrostprotectionactivewhenthepowerandgassupplyareon.

System Protection

Theboileralonecannotensurethattheinstallationisprotectedagainstfrost.NOTE:Anyotherexposedareasofthesystemshouldbeprotectedbyaseparatefrostthermostat.

Incaseofprolongedabsence,wherepowertothedwellingandtheboilerisswitchedoff,contactyourInstallation/ServicingcompanyorGlow-wormServicetohavetheinstallationdrainedortohavetheheatingcircuitprotectedbyaddingananti-freezespeciallydesignedforheatingsystems.

CAUTION: Your domestic water circuit (hot and cold) is not protected by the boiler.

10.3 Condensate Drain Blockage

Asasafetyfeaturetheboilerwillstopworkingifthecondensatedrainbecomesblocked.Duringfreezingconditionsthismaybeduetotheformingoficeinthecondensedrainexternaltothehouse.

• Releaseaniceblockagebytheuseofwarmclothsonthepipe.

Theboilershouldthenrestart.

Page 13: flexicom-cx-user-157168 (1)

0020127401_00 - 06/11 - Glow-worm

HOW TO USE YOUR APPLIANCE

- 13 -

Filling Tap Filling Tap

CODE DESCRIPTION POSSIBLECAUSES

F1 Boilerhasattemptedtolight5timesandfailedonalloccassions

Presstheresetbutton.Ifthefaultpersists,contactyourInstallation/ServicingcompanyorGlow-worm

F5 Overheat Boilerhasoverheated-allowtocoolthenpressresetbutton

F22 Lowwaterpressureorignitiontemperaturerisetooslow

Notenoughwaterinthesystem.Connectthefillingloopundertheboilerandopenbothfillingtaps.When1.0barisshownonthedisplay,closetapsandremovefillingloop.Ifthefaultpersists,contactyourInstallation/ServicingcompanyorGlow-worm

Page 14: flexicom-cx-user-157168 (1)

0020127401_00 - 06/11 - Glow-worm

ANY ASSISTANCE ?

- 14 -

• ContactyourInstallation/ServicingcompanyorGlow-wormserviceifthefaultpersists.

10.4 Safety Discharge Valve

Thesafetydischargevalveanddischargepipeisfittedtotheboiler.

• Ifthereisanydischargefromthepipe,switchofftheboilerelectricalsupply,thencallyourInstallation/ServicingcompanyorGlow-wormservice.

11 Appliance maintenance and servicing

11.1 Cleaning

Before cleaning turn the appliance off.

Theappliancecasingcanbecleanedusingamildliquiddetergentwithadampcloth,thenadryclothtopolish.

Do not use any form of abrasive or solvent cleaner as you may damage the paintwork.

11.2 Regular servicing

Regularservicingoftheapplianceisimportanttotheprolonged,safeandefficientuseofyourappliance.

Incorrect or inadequate servicing can severely affect the safety of the appliance and can lead to injury.

Werecommendthatyourapplianceisservicedeveryyear.

• Onlyuseacompetentperson.

TheserviceengineershouldcompletetherelevantServiceRecordontheBenchmarkChecklistaftereachservice.TheBenchmarkChecklistmayberequiredintheeventofanywarrantyworkandassupportingdocumentationrelatingtohomeimprovementsintheoptionaldocumentssectionoftheHomeInformationPack.

Toobtainservice,callyourinstallerorGlow-worm’sownserviceorganisationusingthetelephonenumberbelow.

Tel:01773828100

11.3 Sealed Water Systems

Thedraining,refillingandpressurisingMUSTbecarriedoutbyacompetent personapprovedatthetimebytheHealthandSafetyExecutive.

• ContactGlow-worm’sownserviceorganisationusingthetelephonenumberbelow.

Tel:01773828100

11.4 Spare Parts

Inordertoguaranteethesafeandprolongedlifeoftheproduct,insistthatonlythemanufacturer’sgenuinesparepartsareused.

• DonotusereconditionedorcopypartsthathavenotbeenclearlyauthorisedbyGlow-worm.

• IfreplacementpartsarerequiredcontactGlow-worm’sownserviceorganisationforadviceusingthetelephonenumberbelow.

Tel:01773828100

orforapprovedstockist,visitwww.glow-worm.co.uk.

Page 15: flexicom-cx-user-157168 (1)

0020127401_00 - 06/11 - Glow-worm

ANY ASSISTANCE ?

- 15 -

Quotethenameandmodeloftheboiler.

Thenameandmodelbadgeisonthefrontcase.

• IfindoubtseekadvicefromthelocalgascompanyorGlow-worm’sownserviceorganisationusingthetelephonenumberbelow.

Tel:01773828100

12 Tips for saving energy

Yourinstallerwillbeabletogiveenergysavingadviceaboutyoursystemanditscontrols.

ForenergysavingadviceyoucancontacttheEnergySavingsTrustforadviceorvisitwww.energysavingtrust.org.ukwhooffersimpleeffectiveadviceaboutsavingenergy.

Regularservicingofyourboilerwillhelpmaintainitsefficiency-servicingonceayearisrecommended

Turnyourthermostatdown.Reducingyourroomtemperatureby1°Ccouldcutyourheatingbillsbyupto10percent.Setyourheatingandhotwateratthetimecontrollertocomeononlywhenrequiredratherthanallthetime.

13 Contact your after-sales organisation

Customer service call

Tel:01773828100

Technical helpline

Tel:01773828300

Page 16: flexicom-cx-user-157168 (1)

0020127401

Glow-worm

Nottingham Road, Belper, Derbyshire. DE56 1JT

Because of our constant endeavour for improvement, details may vary slightly from those shown in these instructions.

www.glow-worm.co.uk

Subj

ect t

o en

gine

erin

g ch

ange

s00

2012

7401

_00 -

06/1

1