flexible risers
TRANSCRIPT
-
8/13/2019 Flexible Risers
1/43
LECC 2011
FLEXIBLE RISERS
-
8/13/2019 Flexible Risers
2/43
-
8/13/2019 Flexible Risers
3/43
Risers
Seabed to surface
Gas, oil, water
Production, Injection, Export
Floating platforms need flexible risers
-
8/13/2019 Flexible Risers
4/43
FPSO
-
8/13/2019 Flexible Risers
5/43
FPF
-
8/13/2019 Flexible Risers
6/43
Pliant wave
-
8/13/2019 Flexible Risers
7/43
Parameters (typical)
Design life 20 years
Length 800 metres +
Internal Diameter 6 to 16 inches
Operating pressure up to 350 bar (80%)
Operating temperature up to 100C
Water depths up to 1000m (70%)
-
8/13/2019 Flexible Risers
8/43
Structure
-
8/13/2019 Flexible Risers
9/43
Structure
-
8/13/2019 Flexible Risers
10/43
Manufacture
-
8/13/2019 Flexible Risers
11/43
Principal Manufacturers
Technip
Wellstream
NKT
Some 1400 km of flexible pipe
manufactured, of which 58% are risers
-
8/13/2019 Flexible Risers
12/43
Failures
Recent survey
1400 static lines
1900 risers
315 reported damage/failure incidents
-
8/13/2019 Flexible Risers
13/43
Failure modes include:
Sheath damage / Flooded annulus
Ageing of Pressure Sheath
End fitting pull-out Vent system malfunction
Carcass collapse
Overbending Abrasive wear
-
8/13/2019 Flexible Risers
14/43
Puncture
-
8/13/2019 Flexible Risers
15/43
Internal collapse
-
8/13/2019 Flexible Risers
16/43
-
8/13/2019 Flexible Risers
17/43
Carcass collapse
-
8/13/2019 Flexible Risers
18/43
Abrasion
-
8/13/2019 Flexible Risers
19/43
Sheath burst
-
8/13/2019 Flexible Risers
20/43
Robert Boyle 1627 - 1691
-
8/13/2019 Flexible Risers
21/43
Condition monitoring
Visual observation (ROV)
Annulus vacuum/pressure testing Gas sampling
Coupon testing
-
8/13/2019 Flexible Risers
22/43
Repair / Replacement
Timescale
Inspection of damaged riser
Cost of manufacture Cost of changeout
-
8/13/2019 Flexible Risers
23/43
Future Focus
Water depth limit?
Operating pressures up to 1300 bar(?)
Operating temperatures New monitoring techniques
Annulus vent system design
Reassessment of corrosion fatigue Investigation of new failure modes
-
8/13/2019 Flexible Risers
24/43
LECC 2011
CONTROL UMBILICALS
-
8/13/2019 Flexible Risers
25/43
Subsea installations
-
8/13/2019 Flexible Risers
26/43
-
8/13/2019 Flexible Risers
27/43
Template
-
8/13/2019 Flexible Risers
28/43
-
8/13/2019 Flexible Risers
29/43
Control functions
Control/monitoring from surface
installation (or shore)
Static and/or dynamic
Valve operations
Downhole monitoring
MEG injection
-
8/13/2019 Flexible Risers
30/43
-
8/13/2019 Flexible Risers
31/43
Structure
-
8/13/2019 Flexible Risers
32/43
-
8/13/2019 Flexible Risers
33/43
Record breaker?
-
8/13/2019 Flexible Risers
34/43
-
8/13/2019 Flexible Risers
35/43
Control from platform
-
8/13/2019 Flexible Risers
36/43
Subsea Control Module
C f f
-
8/13/2019 Flexible Risers
37/43
Control from floating installation
-
8/13/2019 Flexible Risers
38/43
Failure modes
Damage during manufacture UTH damage / jumper cables
Leakage in hydraulic lines
Contamination of hydraulic oil Installation damage including ploughing
Water ingress to electrical components
Loss of insulation resistance (Cables)
Interface with surface installation
-
8/13/2019 Flexible Risers
39/43
-
8/13/2019 Flexible Risers
40/43
-
8/13/2019 Flexible Risers
41/43
-
8/13/2019 Flexible Risers
42/43
Future Focus
Increasing water depth
Increasing complexity of subsea
developments
Fault tracing
Advanced repair methods
-
8/13/2019 Flexible Risers
43/43
Charles Taylor adjusting
INTERNATIONAL LOSS ADJUSTERSPresented by Martin Oinn
Charles Taylor energy
88 Leadenhall Street
London EC3A 3BA
Telephone - +44 (0) 20 7623 1819
Facsimile - +44 (0) 20 7623 1817
Direct Dial - +44 (0) 20 7015 2018