Name: David Ledwith Presentation: Design Strategy for the Deep Retrofit of a Typical Flat Top Social Housing Block Brief: To Develop a Holistic Strategy for the Sustainable Regeneration of the Housing Block Type, with Baseline Targets of achieving an A2 BER Rating and compliance with Current Building Regulations EXISTING PROPOSED

Upload: david-ledwith

Post on 06-May-2015

292 views

Category:

Design


2 download

TRANSCRIPT

Page 1: Flat Top Social Housing Energy Retrofit

Name: David Ledwith

Presentation: Design Strategy for the Deep Retrofit of a Typical Flat Top Social Housing Block

Brief: To Develop a Holistic Strategy for the Sustainable Regeneration of the Housing Block Type, with Baseline Targets of achieving an A2 BER Rating and compliance with Current Building Regulations

EXISTING PROPOSED

Page 2: Flat Top Social Housing Energy Retrofit

EXISTING BUILDING

• 2 x FIVE STOREY BLOCKS• 38 UNITS (MIXTURE of 1,2,3,4 BED)• SINGLE STOREY GROUND FLOOR UNITS & 2 X TWO STOREY DUPLEXES ABOVE• AVERAGE BER OF E1 320kWhr/sq.m/yr•CARBON EMISSIONS OF 128 TONNES

Page 3: Flat Top Social Housing Energy Retrofit

DESIGN ISSUES

1. ENERGY PERFORMANCE

2. TECHNICAL PERFORMANCE

3. SOCIAL & CIVIC PERFORMANCE

- BUILDING HAS A VERY POOR THERMAL PERFORMANCE

- MINIMAL TO ZERO LEVELS OF INSULATION- HIGH LEVELS OF THERMAL BRIDGING- LOW EFFICIENCY HEATING SYSTEMS- CONDENSATION & MOULD PROBLEMS- HIGH CARBON EMISSIONS

- DWELLINGS ARE SMALL (59 sq.m -2 Bed Duplex)- ACCESSIBILITY & FIRE SAFETY ISSUES- GROUND FLOOR LAYOUT & DEFENSIBLE SPACE

- BUILDINGS SET BACK & SURROUNDED WITH RAILINGS- POOR CONTRIBUTION TO URBAN STREETSCAPE- SOCIAL HOUSING STIGMA- FUEL POVERTY

POSITIVES- WELL BUILT STRUCTURES- STRONG COMMUNITIES

Page 4: Flat Top Social Housing Energy Retrofit

3. CREATION COMMUNITY SPACES

2. RE-IMAGINATION OFTHE GROUND PLANE

1. NEW THERMAL ENVELOPE

DESIGN SOLUTION

Page 5: Flat Top Social Housing Energy Retrofit

NEW THERMAL ENVELOPE

EXISITING

STRIP BACK TO ‘WINE RACK’ STRUCTURAL LAYOUT

CONSTRUCT NEW INSULATION LAYER AND BALCONIES

Page 6: Flat Top Social Housing Energy Retrofit

THE SECTION

Page 7: Flat Top Social Housing Energy Retrofit

NEW GROUND FLOOR

- NEW SINGLE STOREY PLINTH- NEW STAIRS & LIFTS - SHARED COURTYARD FORMED- UNITS ACCESSED FROM STREET- COMMUNAL FACILITIES- SHARED LAUNDRY- SECURE STORAGE- COMMUNITY ROOMS

Page 8: Flat Top Social Housing Energy Retrofit

FIRST FLOOR (& THIRD FLOOR)

- PLINTH FORMS A GARDEN - PLAYGROUND AREA- 14 UNITS DUPLEX UNITS- DUPLEX UNIT TYPE - EXTENDED INTO BALCONY &

WALKWAY- BATHROOM MOVED DOWNSTAIRS

Page 9: Flat Top Social Housing Energy Retrofit

SECOND FLOOR (& FOURTH FLOOR)

- UPPER FLOOR OF DUPLEX UNITS- THREE BED UNIT- TRIPLE ASPECT- UNIVERSALLY ACCESSSIBLE

Page 10: Flat Top Social Housing Energy Retrofit

VIEW OF GARDEN LEVEL

Page 11: Flat Top Social Housing Energy Retrofit

FIFTH FLOOR

- NEW FLOOR LEVEL- 3 NO. ONE BED UNITS- COMMUNAL PENTHOUSE ROOM- ALOTMENTS- 10 SQ.M PER UNIT

Page 12: Flat Top Social Housing Energy Retrofit

AXO

- GARDEN PLINTH WITH RECYLING FACILITIES AND CAR CHARGING POINTS

- ALOTMENTS ON THE ROOF- SOLAR PANELS REDUCE ENRGY

DEMAND- BIOMASS FUELLED CHP BOILER USED

TO PROVIDE HEAT

Page 13: Flat Top Social Housing Energy Retrofit

SUMMARY

- NEW URBAN BLOCK CREATED- INTEGRATED AT GROUND FLOOR LEVEL WITH

THE CITY- SAME NUMBER OF UNITS MAINTAINED – 38- UNIT SIZES HAVE INCREASED BY ONE THIRD- DEFINED OPEN SPACES CREATED- COMMUNAL ACCOMODATION CREATED- GARDEN & ALOTMENTS PROVIDED- A2 BER RATING WITH SOLARPANELS & CHP- 36 kWhr/sq.m/yr- NEGATIVE CARBON EMISSIONS –

4.1kgCO2/sq.m/yr

Page 14: Flat Top Social Housing Energy Retrofit

THANK YOU