FlashPro-CC Flash Programmer for the CC series devices - Chipcon product from TI Remote Control Programming User’s Guide PM024A02 Rev.2 December-17-2007 Elprotronic Inc.

Upload: others

Post on 01-Jun-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

FlashPro-CC Flash Programmer

for the CC series devices - Chipcon product from TI

Remote Control Programming User’s Guide

PM024A02 Rev.2

December-17-2007

Elprotronic Inc.

Page 2: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

2

Elprotronic Inc.

16 Crossroads Drive

Richmond Hill,

Ontario, L4E-5C9

CANADA

Web site: www.elprotronic.com

E-mail: [email protected]

Fax: 905-780-2414

Voice: 905-780-5789

Copyright © Elprotronic Inc. All rights reserved.

Disclaimer:

No part of this document may be reproduced without the prior written consent of Elprotronic Inc.

The information in this document is subject to change without notice and does not represent a

commitment on any part of Elprotronic Inc. While the information contained herein is assumed to

be accurate, Elprotronic Inc. assumes no responsibility for any errors or omissions.

In no event shall Elprotronic Inc, its employees or authors of this document be liable for special,

direct, indirect, or consequential damage, losses, costs, charges, claims, demands, claims for lost

profits, fees, or expenses of any nature or kind.

The software described in this document is furnished under a licence and may only be used or copied

in accordance with the terms of such a licence.

Disclaimer of warranties: You agree that Elprotronic Inc. has made no express warranties to You

regarding the software, hardware, firmware and related documentation. The software, hardware,

firmware and related documentation being provided to You “AS IS” without warranty or support

of any kind. Elprotronic Inc. disclaims all warranties with regard to the software, express or implied,

including, without limitation, any implied warranties of fitness for a particular purpose,

merchantability, merchantable quality or noninfringement of third-party rights.

Limit of liability: In no event will Elprotronic Inc. be liable to you for any loss of use, interruption

of business, or any direct, indirect, special incidental or consequential damages of any kind

(including lost profits) regardless of the form of action whether in contract, tort (including

negligence), strict product liability or otherwise, even if Elprotronic Inc. has been advised of the

possibility of such damages.

Page 3: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

3

END USER LICENSE AGREEMENT

PLEASE READ THIS DOCUMENT CAREFULLY BEFORE USING THE SOFTWARE AND

THE ASSOCIATED HARDWARE. ELPROTRONIC INC. AND/OR ITS SUBSIDIARIES

(“ELPROTRONIC”) IS WILLING TO LICENSE THE SOFTWARE TO YOU AS AN

INDIVIDUAL, THE COMPANY, OR LEGAL ENTITY THAT WILL BE USING THE

SOFTWARE (REFERENCED BELOW AS “YOU” OR “YOUR”) ONLY ON THE CONDITION

THAT YOU AGREE TO ALL TERMS OF THIS LICENSE AGREEMENT. THIS IS A LEGAL

AND ENFORCABLE CONTRACT BETWEEN YOU AND ELPROTRONIC. BY OPENING THIS

PACKAGE, BREAKING THE SEAL, CLICKING “I AGREE” BUTTON OR OTHERWISE

INDICATING ASSENT ELECTRONICALLY, OR LOADING THE SOFTWARE YOU AGREE

TO THE TERMS AND CONDITIONS OF THIS AGREEMENT. IF YOU DO NOT AGREE TO

THESE TERMS AND CONDITIONS, CLICK ON THE “I DO NOT AGREE” BUTTON OR

OTHERWISE INDICATE REFUSAL, MAKE NO FURTHER USE OF THE FULL PRODUCT

AND RETURN IT WITH THE PROOF OF PURCHASE TO THE DEALER FROM WHOM IT

WAS ACQUIRED WITHIN THIRTY (30) DAYS OF PURCHASE AND YOUR MONEY WILL

BE REFUNDED.

1. License.

The software, firmware and related documentation (collectively the “Product”) is the property of

Elprotronic or its licensors and is protected by copyright law. While Elprotronic continues to own

the Product, You will have certain rights to use the Product after Your acceptance of this license.

This license governs any releases, revisions, or enhancements to the Product that Elprotronic may

furnish to You. Your rights and obligations with respect to the use of this Product are as follows:

YOU MAY:

A. use this Product on many computers;

B. make one copy of the software for archival purposes, or copy the software onto the hard disk

of Your computer and retain the original for archival purposes;

C. use the software on a network

YOU MAY NOT:

A. sublicense, reverse engineer, decompile, disassemble, modify, translate, make any attempt

to discover the Source Code of the Product; or create derivative works from the Product;

B. redistribute, in whole or in part, any part of the software component of this Product;

Page 4: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

4

C. use this software with a programming adapter (hardware) that is not a product of

Elprotronic Inc.

2. Copyright

All rights, title, and copyrights in and to the Product and any copies of the Product are owned by

Elprotronic. The Product is protected by copyright laws and international treaty provisions.

Therefore, you must treat the Product like any other copyrighted material.

3. Limitation of liability.

In no event shall Elprotronic be liable to you for any loss of use, interruption of business, or any

direct, indirect, special, incidental or consequential damages of any kind (including lost profits)

regardless of the form of action whether in contract, tort (including negligence), strict product

liability or otherwise, even if Elprotronic has been advised of the possibility of such damages.

4. DISCLAIMER OF WARRANTIES.

You agree that Elprotronic has made no express warranties to You regarding the software, hardware,

firmware and related documentation. The software, hardware, firmware and related documentation

being provided to You “AS IS” without warranty or support of any kind. Elprotronic disclaims all

warranties with regard to the software and hardware, express or implied, including, without

limitation, any implied warranties of fitness for a particular purpose, merchantability, merchantable

quality or noninfringement of third-party rights.

Page 5: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

5

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital devices,

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful

interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy

and, if not installed and used in accordance with the instruction manual, may cause harmful interference to

radio communications. However, there is no guarantee that interference will not occur in a particular

installation. If this equipment does cause harmful interference to radio or television reception, which can be

determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one

of more of the following measures:

* Reorient or relocate the receiving antenna

* Increase the separation between the equipment and receiver

* Connect the equipment into an outlet on a circuit different from that to which the receiver is connected

* Consult the dealer or an experienced radio/TV technician for help.

Warning: Changes or modifications not expressly approved by Elprotronic Inc. could void the user’s authority

to operate the equipment.

This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

(1) this device may not cause harmful interference and

(2) this device must accept any interference received,

including interference that may cause undesired

operation.

This Class B digital apparatus meets all requirements of the Canadian

Interference-Causing Equipment Regulations.

Cet appereil numerique de la classe B respecte toutes les exigences du

Reglement sur le material brouilleur du Canada.

Page 6: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

6

Table of Contents

1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

2. Demo program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

3. Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

3.1 Example with single FPA API DLL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

3.2 Example with Multi-FPA API DLL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

4. List of the DLL instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

4.1 Multi-FPA instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

F_Trace_ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

F_Trace_OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

F_OpenInstances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

F_CloseInstances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

F_OpenInstancesAndFPAs, F_OpenInstances_AndFPAs . . . . . . . . . . . . . . 29

F_API_DLL_Directory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

F_Set_FPA_index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

F_Get_FPA_index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

F_Disable_FPA_index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

F_Enable_FPA_index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

F_LastStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

F_Multi_DLLTypeVer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

F_Get_FPA_SN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

4.2 Generic instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

F_Check_FPA_access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

F_DLLTypeVer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

F_Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

F_Close_All . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

F_GetSetup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

F_ConfigSetup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

F_SetConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

F_GetConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

F_DispSetup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Page 7: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

7

F_ReportMessage, F_Report_Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

F_GetReportMessageChar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

F_ReadCodeFile, F_Read_CodeFile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

F_Get_CodeCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

F_ConfigFileLoad, F_Config_FileLoad . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

F_Clr_Code_Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

F_Put_Byte_to_Code_Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

F_Get_Byte_from_Code_Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

F_Put_IEEEAddr64_to_Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

F_Put_IEEEAddr_Byte_to_Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

F_Get_IEEEAddr64_from_Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

F_Get_IEEEAddr_Byte_from_Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

F_Power_Target . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

F_Reset_Target . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

F_Get_Targets_Vcc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

4.3 Encapsulated instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

F_AutoProgram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

F_Verify_Lock_Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

F_Memory_Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

F_Memory_Blank_Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

F_Memory_Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

F_Memory_Verify . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

F_Memory_Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

F_Write_IEEE_Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

F_Read_IEEE_Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

F_Write_Lock_Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

4.4 Sequential instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

F_Open_Target_Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

F_Close_Target_Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

F_Segment_Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

F_Sectors_Blank_Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

F_Write_Byte_to_XRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

F_Read_Byte_from_XRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

F_Write_Byte_to_direct_RAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

F_Read_Byte_from_direct_RAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

F_Copy_Buffer_to_Flash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

F_Copy_Flash_to_Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

F_Copy_Buffer_to_XRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

Page 8: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

8

F_Copy_XRAM_to_Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

F_Copy_Buffer_to_direct_RAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

F_Copy_direct_RAM_to_Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

F_Put_Byte_to_Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

F_Get_Byte_from_Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

F_Set_PC_and_RUN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

F_Get_MCU_Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

Appendix A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

FlashPro-CC Command Line interpreter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

Page 9: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

9

1. Introduction

FlashPro-CC Flash Programmer (USB ) can be remotely controlled from other

software applications (Visual C++, Visual Basic etc.) via a DLL library. The Multi-FPA - allows

to remotely control simultaneously up to eight Flash Programming Adapters (FPAs)

significantly reducing programming speed in production.

Figure 1.1 shows the connections between PC and up to eight programming adapters. The

FPAs can be connected to PC USB ports directly or via USB-HUB. Direct connection to the PC

is faster but if the PC does not have required number of USB ports, then USB-HUB can be used.

The USB-HUB should be fast, otherwise speed degradation can be noticed. When the USB hub

is used, then the D-Link’s Model No: DUB-H7, P/N BDUBH7..A2 USB 2.0 HUB is

recommended.

Figure 1.1

Page 10: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

10

Page 11: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 11

Block diagram of the Multi-FPA application DLL is presented on the Figure 1.2.

To support the Multi-FPA API-DLL feature, the software package contains nine dll files

- the Multi-FPA API-DLL selector

- eight standard single FPAs API-DLLs

Figure 1.3 shows the logical connections between dll files.

Figure 1.2

Page 12: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 12

The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer API-DLL

functions coming from an application software to desired single application dll (FlashProCC-

FPA1.dll to FlashProCC-FPA8.dll).

Note: Software package contains one FlashProCC-FPA1.DLL. Files FlashProCC-

FPA2.DLL to FlashProCC-FPA8.DLL will be copied automatically if required.

The FlashProCC-FPAsel.dll is transparent for all API-DLL functions implemented in the

single API-DLLs functions. Desired destination FPA can be selected using the selector function

added to the Multi-FPA selector (FlashProCC-FPAsel.dll).

F_Set_FPA_index( fpa );

where the

Figure 1.3

Page 13: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 13

fpa = 1 to 8 when the only one desired FPA required to be selected

or

fpa = 0 when ALL active FPAs should be selected.

The selected FPA index modified by the F_Set_FPA_index( fpa ) instruction can be

modified at any time. By default, the FPA index is 1 and if only one FPA is used then fpa index

does not need to be initialized or modified. When the fpa index 1 to 8 is used, then the result is

coming back to application software from the single API-DLL via transparent Multi-FPA

selector. When the fpa index is 0 (ALL-FPAs) and results are the same from all FPAs, then the

same result is passing back to application software. If results are not the same, then the Multi-

FPA selector DLL is returning value -1 (minus 1) and all recently received results can be read

individually using function

F_LastStatus( fpa )

Most of the implemented functions allows to use the determined fpa index 1 to 8 or 0

(ALL-FPAs). When functions return specific value, like read data etc, then only determined FPA

index can be used ( fpa index from 1 to 8). When the fpa index is 0 (ALL-FPAs) then almost all

functions are executed simultaneously. Less critical functions are executed sequentially from

FPA-1 up to FPA-8 but that process can not be seen from the application software.

When the inactive fpa index is selected, then return value from the selected function is -2

(minus 2). When all fpa has been selected (fpa index = 0) then only active FPAs will be serviced.

For example if only one FPA is active and fpa index=0, then only one FPA will be used. It is

save to prepare the universal application software that allows to remote control up to eight FPAs

and on the startup activate only desired number of FPAs.

It should be noticed, that all single API-DLLs (FlashProCC-FPA1.dll to FlashProCC-

FPA8.dll) used with the Multi-FPA DLL (FlashProCC-FPAsel.dll) are fully independent to each

other. From that point of view it is not required that transferred data to one FPA should be the

same as the transferred data to the others FPAs. For example code data downloaded to FPA-1 can

be different that the code data downloaded to the FPA-2, FPA-3 etc. But even in this case the

programming process can be done simultaneously. In this case the desired code should be read

from the code file and saved in the API-DLL-1, next code file data should be saved in the API-

DLL-2 etc. When it is done, then the F_AutoProgram can be executed simultaneously with

selected all active FPAs. All FPAs will be serviced by his own API-DLL and data packages

saved in these dlls.

Page 14: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 14

The FlashPro-CC Flash Programmer software package contains all required files to

remotely control programmer from a software application. When software package is installed

then by default the DLL file, library file and header file are located in:

C:\Program Files\Elprotronic\CCxx\USB FlashPro-CC\API-DLL

FlashProCC-FPAsel.dll - Multi-FPA selection / task manager API- DLL

FlashProCC-FPA1.dll - Single api-DLL for the UAB-FPA

FlashProCC-Dll.h - header file for C++

FlashProCC-Dos-Dll.h - header file for C++ (Borland) or DOS

FlashProCC-FPAsel.lib - lib file for C++

FlashProCC-FPAsel-BC.lib - lib file for C++ (Borland)

config.ini - default configuration file for the FPAs

FPAs-setup.ini - FPAs- vs USB ports configuration file

The FlashProCC-FPAsel.dll contains two groups of the same functions used in C++

application and Visual Basic (or similar) applications All procedure names used in Visual Basic

are starting from VB_xxxx, when the procedure names used in C++ are starting from F_xxxx.

All functions starting from F_xxxx using the _Cdecl declarations used in C++ . Function names

starting from VB_xxxx has the _stdcall calling declaration required in Visual Basic.

Reminding files listed above are required in run time - to initialize the flash programming

adapter (config.ini) and USB setup (FPAs-setup.ini).

When the C++ application is created, then following files should be copied to the source

application directory:

FlashProCC-Dll.h - header file for C++

FlashProCC-FPAsel.lib - lib file for C++ (Microscoft Visual C++)

or

FlashProCC-Dos-Dll.h - header file for C++

FlashProCC-FPAsel-BC.lib - lib file for C++ (Borland C++)

and to the release/debug application directory

FlashProCC-FPAsel.dll - Multi-FPA selection / task manager DLL

FlashProCC-FPA1.dll - API-DLL for the USB-FPA

config.ini - default configuration file for the FPAs

Page 15: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 15

FPAs-setup.ini - FPAs- vs USB ports configuration file

Executable application software package in C++ or when application in Visual Basic is created,

then following files should be copied to the source or executable application directory:

FlashProCC-FPAsel.dll

FlashProCC-FPA1.dll

config.ini

FPAs-setup.ini

All these files ‘as is’ should be copied to destination location, where an application software

using the DLL library.

The config.ini file has default setup information. This file can be modified and taken directly

form the FlashPro-CC Flash Programmer application software. To create required config.ini file

the standard FlashPro-CC Flash programmer software should be open and required setup

(memory option, communication speed etc) should be created. When this is done, programming

software should be closed and the config.ini file with the latest saved configuration copied to

destination location. Note, that the configuration setup can be modified using DLL library

function.

Software package has a demo software written under Visual C++.net. All files and source

code are located in:

C:\Program Files\Elprotronic\CCxx\USB FlashPro-CC\API-DLL-Demo\Cpp

Page 16: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 16

2. Demo program

The demo program is a small GUI program with a lot of buttons allowing to separately

call functions using DLL library package software. Source code and all related project files are

located in the following directory:

C:\Program Files\Elprotronic\CCxx\USB FlashPro-CC\API-DLL-Demo\Cpp

Program can be activated by selecting the FlashProCC-DLL-DemoCpp.exe located in the \release

subdirectory. This demo program can also be activated from the windows menu:

Start->Program->Elprotronic-Flash Programmer->(CCxx) USB FlashPro-CC->FlashProCC-DLL-Demo-

Cpp

Page 17: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 17

When the demo program is activated, then the following dialogue screen is displayed (see figure

2.1). At the beginning the USB-FPA’s configuration file should be created, that contains list off

all FPAs used in the application. Using the Notepad editor the default FPA configuration file

‘FPAs-setup.ini’ should be opened by pressing the “Open FPAs-setup.ini” button in the

dialogue screen.

Take a serial numbers from the FPAs labels and write it on the desired FPAs locations FPA-1 up

to FPA-8. If for example two FPAs will be used with SN 20070031 and 20070032 then the

contents of the FPA’s configuration file will be as follows:

;===================================================================

; USB-FPA configuration setup *

; Elprotronic Inc. *

;-------------------------------------------------------------------

; up to eight FPA can be specified and connected via USB to PC *

Figure 2.1 Demo program dialogue screen using DLLs.

Page 18: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 18

; syntax: *

; FPA-x Serial Number *

; where FPA-x can be FPA-1, FPA-2, FPA-3 .... up to FPA-8 *

; Serial number - get serial number from the desires FPA's label *

; Minimum one FPA's must be specified *

; FPA-x order - any *

; *

; e.g (without semicolon - comment) *

; *

;FPA-1 20050116 *

;FPA-3 20050199 *

;FPA-5 20050198 *

;===================================================================

FPA-1 20070031

FPA-2 20070032

Note, that only lines without comments (without semicolon on the front ) are used by

software. All lines with comment are ignored. The FPA’s serial numbers and FPA’s indexes can

be listed in any order and with gap like FPA-1, FPA-5 etc. without FPA-2, 3 etc. Minimum one

valid FPA with correct SN must be specified. Up to eight FPAs can be declared. When the FPA’s

configuration file is created then file should be saved using name starting from FPA and with

extention ini e.g FPAs-setup.ini.

Connect all required FPA’s to USB connectors and run the FlashProCC-

DLL-Demo-Cpp.exe demo software. First the DLL instances should be opened and all

connected FPA’s should be assigned to desired FPA’s indexes. It is recommended to press the

button ‘FPA assigment’ located inside the frame named ‘From File (recommended)’. When this

button is pressed, then the DLL function named

F_OpenInstancesAndFPAs( FileName );

is called. The list of defined FPA’s serial numbers are taken from the FPAs configuration file and

assigned all FPAs to desired FPA indexes (1 to 8). Number of instances to be opened is

calculated automatically, one per available and valid FPA. On described example with two FPAs

in the ‘FPAs selector’ will display two valid FPAs with list of used FPAs’ serial numbers. All,

others FPA-x fields will be disabled. In this example only two DLL instances becomes opened.

Valid FPA indexes becomes 1,3 and ALL.

Note: When one or more FPA adapters are connected to PC and the “FPAs-setup.ini”

does not contain valid FPA serial numbers, then the first detected FPA (and only one)

will be activated.

Page 19: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 19

Other method (old method - not recommended) that allows to open required number of

instances uses ‘2. Open Instances’ button in ‘Default’ frame. First the number of the instances

should be defined in the ‘Total no of FPAs’ location. When the ‘2. Open Instances’ button is

pressed, then the DLL function named

F_OpenInstances( no );

called where ‘no’ - number of instances to be opened.. When the dll instances are opened, then it

is possible to check the access to the FPA connected to PC via USB ports. Pressing button ‘3.

FPA list’ ( function F_Check_FPA_access(index); called in loop for index = 1,2,3..8 ) allows

to check the access to these adapters. On the end the button ‘4. FPA assignment’ ( function

F_Check_FPA_access(index); with desired ‘fpa’ and USB indexes) allows to assign desired

FPA adapter to ‘fpa’ index. All these steps can be done automatically when the function

F_OpenInstancesAndFPAs( FileName ) described above is used (used button ‘FPA

assigment’ located inside the frame named ‘From File (recommended) ).

When the FPA(s)s has been assigned then all adapters should be activated by pressing the

‘1. Initialization’ button. This initialization calls the DLL function F_Initialization and

communication between programming adapter and PC is established. Report message is

displayed in the report window ( uses the F_ReportMessage function). By default the config.ini

file is empty and to make a required programmer setup the setup file should be downloaded to

programmer. It can be done by pressing the button ‘ 2.Setup File’, (executing

F_ConfigFileLoad DLL function). Setup file can be prepared first using standard FlashPro-CC

programming software with GUI. Also desired code file can be downloaded by pressing the

button ‘3. Open Code’ (executing F_ReadCodeFile DLL function).

There are seven buttons located on the right side of demo dialogue screen. Each of them

calls one encapsulated function from the following list - F_AutoProgram, F_Memory_Erase,

F_Memory_Blank_Check, F_Memory_Write, F_Memory_Verify and F_Memory_Read

When any of these button is pressed, then a function, exactly in the same way how it is

done in the standard FlashPro-CC Flash Programming software (GUI) is executed. Also buttons

Power ON/OFF, RESET has the same action as related buttons in standard programmer. Refer

to the FlashPro-CC Flash Flash Programmer for the CC series devices - User’s Manual for

details of these functions.

In the central part on dialogue screen there are buttons that can call the sequential DLL

functions.

Button Open Target - F_Open_Target_Device();

Page 20: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 20

Button Erase Segment - F_Segment_Erase(....);

Button Blank Check Segm. - F_Sectors_Blank_Check(....);

Button Write Flash Block - F_Copy_Buffer_to_Flash(....);

Button Read Flash Block - F_Copy_Flash_to_Buffer(....)

Button Write XRAM Block - F_Copy_Buffer_to_XRAM(....);

Button Read XRAM Block - F_Copy_XRAM_to_Buffer(....);

Button Write direct RAM - F_Copy_Buffer_to_direct_RAM(....);

Button Read direct RAM - F_Copy_direct_RAM_to_Buffer(....);

Button Set PC and Run - F_Set_PC_and_RUN(....);

Button Close Target - F_Close_Target_Device();

When a sequential function is called then Open Target (calling F_Open_Target_Device

DLL function) must be pressed first. After that any button calling a sequential function can be

pressed - in any order and as many times as required. On the end of sequential communication

the button Close Traget (calling F_Close_Target_Device DLL function) should be pressed.

In the presented demo software all sequential functions have very small task to perform to

demonstrate how to use the DLL functions. See source code of the DLL-Demo program in the

software package in the ..\Demo-DLL subdirectory for details.

Erase Segment: Erase segment at location 0x1000 (segment size 1 or 2k )

Blank Check Segm. Segment blank check Erase at location 0x1000 to 0x107F

Write Flash Block Write 16 bytes to the flash memory at location 0x1020 to 0x102f using

function

F_Copy_Buffer_to_Flash( 0x1020, 16);

Following data are written no targets:

0x1020 -> 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

Read Flash Block Read 64 bytes from target device starting from the flash memory address

at 0x1000. On the report screen only 16 bytes from each target devices

taken from addresses 0x1020 to 0x102F are displayed.

Write XRAM Block Write 16 bytes to XRAM at location 0xF000 to 0xF00F using function

F_Copy_Buffer_to_XRAM( 0xF000, 16);

Following data are written no targets:

30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F

Page 21: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 21

Read XRAM Block Read 16 bytes XRAM starting from address at 0xF000. On the report

screen 16 bytes from each target devices taken from addresses 0xF000 to

0xF00F are displayed

Write direct RAM Write 16 bytes to direct RAM at location 0x60 to 0x6F using function

F_Copy_Buffer_to_direct_RAM( 0x60, 16);

Following data are written no targets:

40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F

Read direct RAM Read 16 bytes direct RAM starting from address at 0x60. On the report

screen 16 bytes from each target devices taken from addresses 0x60 to

0x6F are displayed

Set PC and Run Small program is written and downloaded to each target devices.

Following program is saved in the XRAM at location stated from 0xF100.

//Downloaded code to RAM - address 0xF100

0xC2, 0xAF, // clr EA (Enable mask)

0xE4, // clr A

0x90, 0xF0, 0x00, // mov DPTR, #0xF000

0x79, 0x10, // mov R1, #0x10

loop:

0xF0, // movx @dptr,A

0x04, // inc A

0xA3, // inc dptr

0xD9,0xFB, // DJNZ R1,loop

//done, fake a breakpoint

0xA5, // DB 0xA5

0x00, // NOP

Written program is modifying contents of the XRAM at locations 0xF000

to 0xF00F. The new XRAM vales should be 0x00, 0x01, 0x02,..... 0x0F.

When the Set PC and Run program is pressed, then the contents described

above is downloaded to XRAM and function

Set_PC_and_RUN( 1, 0xF100 );

Page 22: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 22

is executed. When program is finished, then XRAM at location should be

modified. XRAM contents can be read by pressing the Read XRAM Block

button.

To make a test do following steps (from the beginning):

1. FPA List

2. Initialization

3. Setup File

4. Power from FPA - Enable

5. Open Target

6. Write XRAM Block

7. Read XRAM Block ( remember XRAM contents)

8. Set PC and RUN

9. Read XRAM Block ( compare with the contents from point 7 ).

On the right part of the dialogue screen are located buttons with encapsulated functions

like Autoprogram, Erase Flash etc. Encapsulated functions are not requires to call the

F_Open_Target_Device() function. All functions, including “Open..”, “Close...” are build-in

inside the encapsulated functions (see chapter 4 for details).

Page 23: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 23

3. Getting Started

The Multi-FPA API-DLL software package is the same for the application written under

Visual C++, Visual Basic, LabView etc. When the desired application is created then all files

from the Elprotronic directory

C:\Program Files\Elprotronic\CCxx\USB FlashPro-CC\API-DLL

should be copied to the executable destination directory.

It is recommended to start the standard FlashPro-CC (GUI) programming software to

verify if the hardware and the drivers setup are correct. Using the FlashPro-CC programming

software the fully functional setup that satisfy desired requirements should be created. When it is

done then using the “File->Save Setup as..” option the configuration file should be saved. This

file can be used “as is” in the application uses Multi-FPA API-DLL. Copy and paste the required

configuration to your destination directory, where your application software is installed. It is

recommended to use the demo program and verify if the setup in your PC and destination

directory are done correctly. To do that copy the executable file

FlashProCC-DLL-DemoCpp.exe

from location

C:\Program Files\Elprotronic\CCxx\USB FlashPro-CC\API-DLL-Demo\Cpp\release

to your destination location where your application software is installed. Run the demo program.

Follow instruction described in chapter 2 how to use the demo program.

3.1 Example with single FPA API DLL

The API-DLL always uses two API-DLL - selector DLL and AOI-DLL. When one FLA

is used only, then selector DLL always sould select the first FPA. Also it is recommended to use

the first detected FPA, since only one FPA is typically connected to PC. The application software

can be simplified in this case. All instructions related to single FPA are detailed described in the

chapters 4.2, 4.3 and 4.4. Instructions specific to Multi-FPA features described in the chapter 4.1.

Initialization opening procedure for the USB-FPA can be as follows:

Page 24: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 24

F_OpenInstancesAndFPAs( “*# *” ); // DLL and FPA (one only) initialization

F_Set_FPA_index( 1 ); // select FPA 1 for

F_Initialization( ); // init FPA

Below is an example of the simplified (without error handling procedures) application

program written in C++ that allows to initialize one FPA, and run an autoprogram with the same

features like an autoprogram in the standard FlashPro-CC (GUI) software.

1. Download data to target device

F_OpenInstancesAndFPAs( “*# *” ); // DLL and FPA (one only) initialization

F_Set_FPA_index( 1 ); // select FPA 1

F_Initialization( ); // init FPA

F_ReadConfigFile( filename ); // read configuration data and save

// to API-DLL

F_ReadCodeFile( format, filename ); // read code data and save to DLL

do

{

status = F_AutoProgram(1); //start autoprogram

if ( status != TRUE )

{

status = F_LastStatus(1);

................................................

}

else

{

................................................

}

} while(1); //make an infinite loop until last target device programmed

.................................................................

F_CloseInstances();

3.2 Example with Multi-FPA API DLL

The code example described below uses Multi-FPA API-DLL. The Multi-FPA API-DLL

is a shell that allows to transfer incoming instructions from the application software to desired

FPA. All instructions related to single FPA are detailed described in the chapters 4.2, 4.3 and 4.4.

Instructions specific to Multi-FPA features described in the chapter 4.1.

Page 25: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 25

Initialization opening procedure for the USB-FPA can be as follows: F_OpenInstancesAndFPAs( FPAs-setup.ini); // DLL and FPA initialization

F_Set_FPA_index( ALL_ACTIVE_FPA ); // select all FPA’s

F_Initialization( ); // init all FPA’s

In the example above number of the opened USB-FPAs are specified in the ‘FPAs-setup.ini’

Below is an example of the simplified (without error handling procedures) application

program written in C++ that allows to initialize all dlls and FPA, and run an autoprogram with

the same features like an autoprogram in the standard FlashPro-CC (GUI) software.

1. Download data to all target devices (uses USB-FPAs)

F_OpenInstancesAndFPAs( FPAs-setup.ini); // DLL and FPA initialization

F_Set_FPA_index( ALL_ACTIVE_FPA ); // select all FPA’s

F_Initialization( ); // init all FPA’s

F_ReadConfigFile( filename ); // read configuration data and save

// to all API-DLLs

F_ReadCodeFile( format, filename ); // read code data and save to all

// API-DLLs

do

{

status = F_AutoProgram( 1 );

//start autoprogram-to program all targets simultaneously with

//the same downloaded data to all target devices.

if ( status != TRUE )

{

if ( status == FPA_UNMACHED_RESULTS )

{

for (n=1; n<=MAX_FPA_INDEX; n++ ) status[n] = = F_LastStatus( n);

................................................

}

else

{

................................................

}

}

} while(1); //make an infinite loop until last target device programmed

.................................................................

F_CloseInstances();

Note, that all single API-DLL are independent from each others and it is not required that all

data and configuration should be the same for each API-DLLs (each FPAs, or target devices) .

For example - code data downloaded to the target devices connected to first FPA can be the same

Page 26: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 26

(but it is not required) as code data downloaded to the target devices connected to second FPA

etc. In the example below the downloaded code to target devices are not the same .

2. Download independent data to target devices (uses USB-FPAs)

F_OpenInstancesAndFPAs( FPAs-setup.ini); // DLL and FPA initialization

F_Set_FPA_index( ALL_ACTIVE_FPA ); // select all FPA’s

F_Initialization( ); // init all FPA’s

.................................................................

F_Set_FPA_index( ALL_ACTIVE_FPA ); // select all FPA’s

F_ReadConfigFile( filename ); // read configuration data and save

// to all API-DLLs

F_Set_FPA_index( 1 ); // select FPA 1

F_ReadCodeFile( format, filename1 ); // read code data and save to

// API-DLL-1

F_Set_FPA_index( 2 ); // select FPA 2

F_ReadCodeFile( format, filename2 ); // read code data and save to

// API-DLL-2

................................................................

F_Set_FPA_index(7 ); // select FPA 7

F_ReadCodeFile( format, filename7 ); // read code data and save to

// API-DLL-7

F_Set_FPA_index( 8 ); // select FPA 8

F_ReadCodeFile( 8, format, filename8 ); // read code data and save to

// API-DLL-8

F_Set_FPA_index( ALL_ACTIVE_FPA ); // select all FPA’s

do

{

status = F_AutoProgram( 1 );

//start autoprogram - to program all targets simultaneously

//with the independent downloaded data to all target devices.

if ( status != TRUE )

{

if ( status == FPA_UNMACHED_RESULTS )

{

for (n=1; n<=MAX_FPA_INDEX; n++ ) status[n] = = F_LastStatus( n);

................................................

}

else

{

................................................

}

}

} while(1); //make an infinite loop until last target device programmed

.................................................................

F_CloseInstances();

Page 27: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 27

4. List of the DLL instructions

All DLL instructions are divided to four groups - related to Multi-FPA selector, single

FPA generic, single FPA encapsulated and single FPA sequential instructions. Multi-FPA

specific instructions are related to the Multi-FPA DLL only. Generic instructions are related to

initialization programmer process, while encapsulated and sequential instructions are related to

target device’s function. Encapsulated and sequential instructions can write, read, and erase

contents of the target device’s flash memory.

Multi-FPA specific instructions are related to load and release the single-FPA dlls,

selection of the transparent path and sequential/simultaneous instructions transfer management.

All other instructions are related to single FPAs.

Generic instructions are related to initialization programmer process, configuration setup

and data preparation, Vcc and Reset to the target device. Generic instructions should be called

first, before encapsulated and sequential instruction.

Encapsulated instructions are fully independent executable instructions providing access

to the target device. Encapsulated instructions can be called at any time and in any order. When

called then all initialization communication with the target device is starting first, after that

requested function is executed and at the end communication with the target device is terminated

and target device is released from the programming adapter.

The encapsulated functions should be mainly used for programming target devices. These

functions perform most tasks required during programming in an easy to use format. These

functions use data provided in Code Files, which should be loaded before the encapsulated

functions are used. To augment the functionality of the encapsulated functions, sequential

functions can be executed immediately after to complete the programming process.

Sequential instructions allow access to the target device in a step-by-step fashion. For

example, a typical sequence of instructions used to read data from the target device would be to

open the target device, then read data and then close the target device. Sequential instruction

have access to the target device only when communication between target device and

programming adapter is initialized. This can be done when Open Target Device instruction is

called. When communication is established, then any number of sequential instruction can be

called. When the process is finished, then at the end Close Target Device instruction should be

called. When communication is terminated, then sequential instructions can not be executed.

Note: Inputs / outputs has been defined as INP_X defined as 4 bytes long (see header file )

#define INP_X _int32

Make sure that an application using the DLL file has the same length of desired data.

Page 28: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 28

4.1 Multi-FPA instructions

The Multi-FPA API-DLL instructions are related to Multi-FPA selector only. These

instructions allows to initialize all single applications dlls and select the instruction patch

between application software and desired FPA and sequential/simultaneous instructions transfer

management Up to eight independent FPAs can be remotely controlled from the application

software. All instructions from application software can be transferred to one selected FPA or to

all FPAs at once. That feature allows to increase programming speed up to eight times and also

allows to have individual access to any FPA is required.

F_Trace_ON

F_Trace_ON - This function activate the tracing.

Syntax:

void MSPPRG_API F_Trace_ON( void );

The F_Trace_ON() opens the DLLtrace.txt file located in the current directory and records all

API-DLL instructions called from the application software. This feature is useful for debugging.

When debugging is not required then tracing should be disabled. Communication history

recorded in the in the last session can be viewed in the DLLtrace.txt located in the directory

where the API-DLL file is located. When the new session is established then the file

DLLtrace.txt is erased and new trace history is recorded.

Note: Tracing is slowing the time execution, because all information passed from application

software to API-DLL are recorded in the dlltrace.txt file.

F_Trace_OFF

F_Trace_OFF - Disable tracing, See F_Trace_ON for details.

Syntax:

void MSPPRG_API F_Trace_OFF( void );

F_OpenInstances

Page 29: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 29

F_OpenInstances - API-DLL initialization in the PC.

Instruction must be called first - before all other instruction. Instead this function the

F_OpenInstancesAndFPAs can be used.

Important: It is not recommended to use this function. Function used only for compatible with

the old software. Use the F_OpenInstancesAndFPAs instead.

Do not use the F_OpenInstances or F_Check_FPA_access after using the

F_OpenInstancesAndFPAs. The F_OpenInstancesAndFPAs is assigning the FPAs to

USB ports and it is not recommended to reassign once again the USB port using the

F_Check_FPA_access function. To check the communication activity with FPA use the

F_Get_FPA_SN function that allows to check te communication with the FPA adapter

without modifying the USB ports assignment.

Syntax: INT_X MSPPRG_API F_OpenInstances ( BYTE no );

Parameters: no -> number of the single API-DLL to be open

no -> 1 to MAX_USB_DEV_NUMBER

where MAX_USB_DEV_NUMBER = 16

Return value:number of opened instances

F_CloseInstances

F_CloseInstances - Close all active API-DLLs and free system memory.

Syntax: INT_X MSPPRG_API F_CloseInstances ( void );

Parameters: void no -> 1 to MAX_USB_DEV_NUMBER

where MAX_USB_DEV_NUMBER = 16

Return value:TRUE

F_OpenInstancesAndFPAs, F_OpenInstances_AndFPAs

Page 30: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 30

F_OpenInstancesAndFPAs - API-DLL initialization in the PC and FPA scan and

or F_OpenInstances_AndFPAs assignment to desired USB port according to contents of the

FPA’s list specified in the string or FPA’s configuration file.

Instruction must be called first - before all other instruction. Instead this function the

F_OpenInstances can be used. Function can be used only when the USB FPA are used. When the

USB-FPA is used, then the function F_OpenInstancesAndFPAs is recommended in the initialization

process. Function is very convenient - automatically is opening the number of the desired API-DLL

and assigning the desired FPA to available USB ports. Regardless of the USB port open sequence

and connection of the FPA to USB ports, the F_OpenInstancesAndFPAs instruction is reading the

FPA’s list, scanning all available FPAs connected to any USB ports and assigning the indexes to all

FPAs according to contents of the FPA list (from strinc or configuartion file). All FPAs not listed

in the FPA configuration file and connected to USB ports are ignored.

Important: Do not use the F_Check_FPA_access after using the F_OpenInstancesAndFPAs.

The F_OpenInstancesAndFPAs is assigning the FPAs to USB ports and it is not

recommended to reassign once again the USB port using the F_Check_FPA_access

function. To check the communication activity with FPA use the F_Get_FPA_SN

function that allows to check te communication with the FPA adapter without

modifying the USB ports assignment.

Syntax: INT_X MSPPRG_API F_OpenInstancesAndFPAs( char * List );

INT_X MSPPRG_API F_OpenInstances_AndFPAs( CString List );

Parameters:

1. When the first two characters in the List string are *#, then string reminding characters

contains list of desired FPAs serial numbers assigned to FPA-1, -2, ...-n indexes, eg.“*# 20060123, 20060234, 20060287"

2. When the first two characters in the List string are not *#, then string contains file name

or full path of the file with list of the FPA’s serial numbers, eg. “C:\Program Files\Elprotronic\FPAs-setup.ini”

Return value:number of opened instances

1. The FPA list in the string:

Page 31: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 31

String -> “*# SN1, SN2, SN3, SN4, SN5...”

Where the

SN1- FPA’s serial number that should be assigned to FPA-1 index

SN2- FPA’s serial number that should be assigned to FPA-2 index

etc.

As a delimiter the comma ‘,’ or white space ‘ ’ can be used.

Example:

“*# 20060123, 0, 20060346, 20060222, 20060245"

or

“*# 20060123 0 20060346 20060222 20060245"

In example above the FPAs will be assigned as follows: FPA-1 20060123

FPA-2 0 //empty - FPA is not assigned

FPA-3 20060346

FPA-4 20060222

FPA-5 20060245

In the FPA list can be specified ONE adapter with any serial number when the character ‘*’ is used

instead the FPA’s serial number. Only one ‘*’ character can be specified in the FPA list and must

be located on the end of valid SN list. All other serial numbers specified after ‘*’ will be ignored.

This option allows to specify any FPA when the only one adapter is used eg.

“*# *"

FPA-1 -> Any FPA is one adapter is connected, or the first detected adapter, if more then one adapters are

connected.

or if more then one adapter is used

“*# 20060123 *" FPA-1 20060123

FPA-2 - first detected adapter (excluding already assigned adapters), if

more adapters are connected.

When the ‘*’ is inside the FPA list, eg.

“*# 20060123 * 20060137 20060166"

then the last two FPA’s SN will be ignored FPA-1 20060123

FPA-2 - first detected adapter (excluding already assigned adapters), if

more adapters are connected.

FPA-3 - not assigned

Initialization example:

1. F_OpenInstances_AndFPAs( “*# *” ); // only one FPA - any SN

or

Page 32: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 32

2. F_OpenInstances_AndFPAs( snlist ); // hardcoded SN list

or

3. // scanned available FPA’s SN list

long SN[MAX_USB_DEV_NUMBER+1], Snr[MAX_USB_DEV_NUMBER+1];

CString snlist;

char * buf[20];

F_OpenInstances( 1 ); // DLL initialization - one instance

F_Set_FPA_index( 1 ); // select access to the first instance

n = 0; //number of detected FPAs

for( k=1; k<=MAX_USB_DEV_NUMBER ; k++ )

{

SN[k] = F_Check_FPA_access(k);

if ( SN[k] > 20000000 ) n++;

}

F_CloseInstances();

// write your own procedure .......

// remap available FPAs SN to desired FPAs order from SN[k] to Snr[p]

snlist = “*#”;

for( k=1; k<=n ; k++ )

{

sprintf( buf, “ %8.8li”, Snr[k] );

snlist += buf;

}

F_OpenInstances_AndFPAs( snlist );

2.The FPA list in the configuration file:

String -> “C:\Program Files\Elprotronic\FPAs-setup.ini”

Example of the FPA configuration file:

; -> semicolon - comment

; Syntax of the FPAs configuration specified

; FPA-x Serial Number

; where FPA-x can be FPA-1, FPA-2, FPA-3 .... up to FPA-8

; e.g

FPA-1 20050116

FPA-3 20050199

FPA-5 20050198

FPA-6 20050205

; FPA-x can be listed in any order and can contain gaps,

; like above without FPA-2, FPA-4

; When list like above is used, then following fpa can be valid

; fpa -> 1,3,5,6

Page 33: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 33

; NotePad editor can be used to create the FPA configuration file.

When the ‘*’ is used instead FPA’s SN, then any FPA will be accepted. The ‘*’ can be used only

once and on the end of the FPA’s list eg.

FPA-1 20050116

FPA-3 20050199

FPA-5 *

or

FPA-1 *

when only one adapter (any adapter) is used.

Example:F_OpenInstancesAndFPAs( FPAs-setup.ini );

//DLL startup and FPA assignment

F_Set_FPA_index (ALL_ACTIVE_FPA);

//select all available FPAs

F_Initialization();

//init all FPAs

F_ReadConfigFile( filename );

//download the same configuration to all DLLs.

F_ReadCodeFile( format, filename );

//download the same code file to all DLLs.

do

{

status = AutoProgram(1);

//start autoprogram to all FPAs simultaneously.

if( status != TRUE )

{

if( status == FPA_UNMATCHED_RESULTS )

{

// service software when results from FPAs are not the same

}

else

{

}

.......................

{

.......................

} while(1);

F_CloseInstances();

// release DLLs from memory

Page 34: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 34

F_API_DLL_Directory

F_API_DLL_Directory - The DLL directory location.

VALID FPA index - irrelevant - the same directory location for all DLLs.

The F_API_DLL_Directory command can specify the directory path where the DLLs are

located. This command is not mandatory and usually is not required. But in some application

software (like in the LabVIEW) the default location of the DLLs is not transferred to the DLL. In

this case the related files with DLLs like MSPlist.ini located in the same directory where the

DLLs are located can not be find. To avoid this problem the full path of the directory where the

DLLs are located can be specified. The F_API_DLL_Directory must be used before

F_Initialization() function.

Syntax:MSPPRG_API void F_API_DLL_Directory( Cstring APIDLLpath );

or MSPPRG_API void F_APIDLL_Directory( char* APIDLLpath );

Example:

............................

F_API_DLL_Directory( “C:\\Program Files\\Test\\LabVIEW” );

// directory where the API-DLLs and MSPlist.ini are located

// C:\Program Files\Test\LabVIEW

If( F_Initialization() != TRUE ) //required API-Dll - initialization

{

// Initialization error

}

F_Set_FPA_index

F_Set_FPA_index - Select desired FPA index (desired DLL instance)

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs).

Syntax: INT_X MSPPRG_API F_Set_FPA_index ( BYTE fpa );

Parameters: fpa -> 1 to MAX_FPA_INDEX where MAX_FPA_INDEX = 8

or 0 -> ALL_ACTIVE_FPA

note: instead of ‘0' value it can be used global defined ALL_ACTIVE_FPA that is defined as

Page 35: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 35

#define ALL_ACTIVE_FPA 0

in the header file

Return value:TRUE - if used fpa index is valid

FPA_INVALID_NO - if used fpa index is not activated or out of range

note: FPA_INVALID_NO -> -2 (minus 2)

F_Get_FPA_index

F_Get_FPA_index - Get current FPA index

Syntax: BYTE MSPPRG_API F_Get_FPA_index ( void );

Return value:current FPA index

F_Disable_FPA_index

F_Disable_FPA_index - Disable desired FPA index (desired DLL instance)

VALID FPA index - ( 1 to 8 )

Function allows to disable communication with selected FPA adapter. From application point of

view, all responses will be the same as from the not active FPA. Communication with target

devices connected to selected FPA will be stopped. When the F_Set_FPA_index(0) will be used,

then selected FPA will be ignored. Result will not be presented in the Status results (Status and

F_LastStatus(..)).

Syntax:

void MSPPRG_API F_Disable_FPA_index ( BYTE fpa );

Parameters: fpa -> 1 to MAX_FPA_INDEX where MAX_FPA_INDEX = 8

F_Enable_FPA_index

F_Enable_FPA_index - Enable desired FPA index (desired DLL instance)

VALID FPA index - ( 1 to 8 )

Page 36: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 36

Function allows to enable communication with selected FPA adapter if the mentioned FPA has

been disabled using the function F_Disable_FPA_index(...). By default, all FPAs are enabled.

Syntax: void MSPPRG_API F_Enable_FPA_index ( BYTE fpa );

Parameters:

fpa -> 1 to MAX_FPA_INDEX where MAX_FPA_INDEX = 8

F_LastStatus

F_LastStatus - Get current FPA index

VALID FPA index - ( 1 to 8 )

Syntax: INT_X MSPPRG_API F_LastStatus ( BYTE fpa );

Parameters:fpa - FPA index of the desired status

fpa index -> 1..8

Return value:Last status from the desired FPAs

All F_xxx functions returns the same parameters (status) as the original API_DLL is returning.

When function is transferred to all API-DLLs (when the fpa=0) then returned parameter (status)

is the same as the returned value from the API-DLLs when the ALL returned values ARE THE

SAME. If not, then returned value is

FPA_UNMATCHED_RESULTS

(value of the FPA_UNMATCHED_RESULTS is minus 1).

To get the returned values from each FPAs, use the

For( n=1; n<=8; n++) status[n] = F_LastStatus( n);

where n -> desired FPA index

and get the last status data from FPA-1, 2, .. up to .8

F_Multi_DLLTypeVer

Page 37: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 37

F_Multi_DLLTypeVer function returns integer number with DLL ID and software revision

version.

Syntax: MSPPRG_API INT_X F_Multi_DLLTypeVer( void );

Return value:VALUE = (DLL ID) | ( 0x0FFF & Version)

DLL ID = 0x1000 - Single DLL for the Parallel Port MSP430-FPA

DLL ID = 0x2000 - Single DLL for the USB MSP430-FPA (FlashPro430)

DLL ID = 0x3000 - Single API-DLL for the GangPro430

DLL ID = 0x4000 - Single API-DLL for the FlashPro-CC

DLL ID = 0x5000 - Single API-DLL for the GangPro-CC

DLL ID = 0x6000 - Multi-FPA API-DLL for the FlashPro430

DLL ID = 0x7000 - Multi-FPA API-DLL for the GangPro430

DLL ID = 0x8000 - Multi-FPA API-DLL for the FlashPro-CC

DLL ID = 0x9000 - Multi-FPA API-DLL for the GangPro-CC

Version = (0x0FFF & VALUE)

F_Get_FPA_SN

F_Get_FPA_SN - Get FPAs Serial number assigned to selected FPA-index (selected

DLL instance number).

Syntax: INT_X MSPPRG_API F_Get_FPA_SN ( BYTE fpa );

Parameters:fpa - FPA index of the desired status

fpa index -> 1..8

Return value:Serial number of the selected FPA

or FPA_INVALID_NO - if used fpa index is not activated or out of range.

note: FPA_INVALID_NO -> -2 (minus 2)

Page 38: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 38

4.2 Generic instructions

Generic instructions are related to initialization programmer process, configuration setup and

preparation data, turning ON and OFF target’s DC and RESET target device. Any communication

with the target device is provided when any of the generic instruction is executed. Generic

instructions should be called before encapsulated and sequential instruction.

F_Check_FPA_access

F_Check_FPA_access - Check available Flash Programming Adapter connected to specified

USB drivers (USB driver index from 1 to 16)

Important: It is not recommended to use this function. Function used only for compatible with

the old software. Use the F_OpenInstancesAndFPAs instead.

Do not use the F_OpenInstances or F_Check_FPA_access after using the

F_OpenInstancesAndFPAs. The F_OpenInstancesAndFPAs is assigning the FPAs to

USB ports and it is not recommended to reassign once again the USB port using the

F_Check_FPA_access function. To check the communication activity with FPA use the

F_Get_FPA_SN function that allows to check te communication with the FPA adapter

without modifying the USB ports assignment.

VALID FPA index (DLL instance number) - ( 1 to 8 )

F_Check_FPA_access should be called as a first function when the *.dll is activated. Function

returns serial number of the detected flash programming adapter, or zero, if programming adapter

has not been detected with selected USB driver. Up to 16 USB drivers can be scanned.

To make a Multi-FPA software back compatible, the F_Check_FPA_access procedure is calling

the function F_OpenInstances if none of the instances has not been activated before. That

allows to use old application software without calling the new type of Multi-FPA functions.

Syntax:

MSPPRG_API INT_X F_Check_FPA_access ( INT_X USB_index );

Parameters:

Index: USB driver index from 1 to MAX_USB_DEV_NUMBER

where MAX_USB_DEV_NUMBER = 16

Page 39: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 39

Return value:

0 - FALSE

>0 - Detected FPA’s Serial Number

Example:

long SN[MAX_USB_DEV_NUMBER+1];

F_OpenInstances( 1 ); // DLL initialization - one instance

F_Set_FPA_index( 1 ); // select access to the first instance

n = 0; //no of detected FPAs

for( k=1; k<=MAX_USB_DEV_NUMBER ; k++ )

{

SN[k] = F_Check_FPA_access(k);

if ( SN[k] > 0 ) n++;

}

F_CloseInstances(); // DLL initialization - one instance

F_OpenInstances( n ); // Open ‘n’ instances - one per FPA

// Find desired FPAs SN and assign the FPAs serial number every time to the

same // FPA-index.

// For example if the

// SN[1]= 20060123

// SN[2]= 20060147

// SN[3]= 0 - adapter not present

// SN[4]= 20060135

// and desired assignment

// FPA-1 20060123

// FPA-2 20060135

// FPA-3 20060147

// then following sequence instructions can be used

F_Set_FPA_index( 1 ); // select access to the first instance

F_Check_FPA_access( 1 ); //assign FPA SN[1] = 20060123 to FPA-1

F_Set_FPA_index( 2 ); // select access to the second instance

F_Check_FPA_access( 4 ); //assign FPA SN[4] = 20060135 to FPA-2

F_Set_FPA_index( 3 ); // select access to the third instance

F_Check_FPA_access( 2 ); //assign FPA SN[2] = 20060147 to FPA-3

F_Set_FPA_index( ALL_ACTIVE_FPA ); // select all active instances

F_Initialization() // All FPAs initialization

............................

Page 40: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 40

F_DLLTypeVer

F_DLLTypeVer - Get information about DLL software type and software revision.

VALID FPA index - ( 1 to 8 )

F_DLLTypeVer function returns integer number with DLL ID and software revision version

and copying text message to report message buffer about DLL ID and software revision. Text

content can downloaded using one of the following functions

F_GetReportMessageChar( index )

or F_ReportMessage( text )

Syntax: MSPPRG_API INT_X F_DLLTypeVer( void );

Return value:VALUE = (DLL ID) | ( 0x0FFF & Version)

DLL ID = 0x1000 - Single DLL for the Parallel Port MSP430-FPA

DLL ID = 0x2000 - Single DLL for the USB MSP430-FPA (FlashPro430)

DLL ID = 0x3000 - Single API-DLL for the GangPro430

DLL ID = 0x4000 - Single API-DLL for the FlashPro-CC

DLL ID = 0x5000 - Single API-DLL for the GangPro-CC

DLL ID = 0x6000 - Multi-FPA API-DLL for the FlashPro430

DLL ID = 0x7000 - Multi-FPA API-DLL for the GangPro430

DLL ID = 0x8000 - Multi-FPA API-DLL for the FlashPro-CC

DLL ID = 0x9000 - Multi-FPA API-DLL for the GangPro-CC

Version = (0x0FFF & VALUE)

Example:INT_X id;

.......................

.......................

id = F_DLLTypeVer();

Disp_report_message();

//see F_ReportMessage or F_GetReportMessage for details

.......................

F_Initialization

F_Initialization - Programmer initialization.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Page 41: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 41

F_Initialization function should be called after the communication with the FPA adapter is

established. To make a Multi-FPA software back compatible, the F_Initialization procedure is

calling the function F_OpenInstances if none of the instances has not been activated before.

That allows to use old application software without calling the new type of Multi-FPA functions.

In this case the F_Check_FPA_access function can be used to activate communication between

PC and Programming Adapter. When the F_Check_FPA_access is not called then by default

the USB driver number “1" is selected.

When the F_Initialization is called then:

- all internal data is cleared or set to the default value,

- initial configuration is downloaded from the config.ini file,

- USB driver is initialized if has not been initialized before (for the USB version

programmer) or Parallel Port becomes open (for the parallel port version programmer).

Programming adapter must be connected to the USB or Parallel Port to establish communication

between PC and programming adapter. Otherwise the F_Initialization will return FALSE result.

Syntax: MSPPRG_API INT_X F_Initialization( void );

Return value:0 - FALSE

1 - TRUE

4 - Programming adapter not detected.

Example: ............................

F_API_DLL_Directory( “.....” ) // optional - see F_API_DLL_Directory()

If( F_Initialization() != TRUE ) //required API-Dll - initialization

{

// Initialization error

}

............................

F_Close_All

F_Close_All - Close communication with the programming adapter and release

PC memory.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Page 42: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 42

F_Close_All function should be called as the last one before *.dll is closed. When the

F_Close_All is called then communication port becomes closed and all internal dynamic data

will be released from the memory. To activate communication with the programmer when the

function F_Close_All has been used the F_Initialization function must be called first.

Syntax: MSPPRG_API INT_X F_Close_All( void );

Return value:0 - FALSE

1 - TRUE

Example:F_Initialization(); //required API-Dll - initialization

............................

............................

F_Close_All;

............................

F_GetSetup

F_GetSetup - Get configuration setup from the programmer.

VALID FPA index - ( 1 to 8 )

See F_ConfigSetup description for more details.

Syntax:MSPPRG_API INT_X F_GetSetup( CFG_BLOCK *config );

Return value:0 - FALSE

1 - TRUE

F_ConfigSetup

F_ConfigSetup - Setup programmer’s configuration.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Page 43: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 43

The F_ConfigSetup can modify configuration of the programmer. When the

F_ConfigSetup is called, then the structure data block is transferred from the software application

to the programmer software. Current programmer setup can be read using function setup

F_GetSetup. When data block is taken from the programmer, then part or all of the configuration

data can be modified and returned to programmer using F_ConfigSetup function. Configuration

data structure and available data for all listed items in this structure are defined below. Listed

name and indexes in the [] brackets are related to the F_SetConfig and F_GetConfig

instructions

See F_Set_Config(....) for detailed description of the all configuration data contents.

typedef struct

{

INT_X DeviceIndex;

INT_X PowerTargetEn;

INT_X CommSpeedIndex;

INT_X ResetTimeIndex;

INT_X CustomResetPulseTime;

INT_X CustomResetIdleTime;

INT_X RstVccOffTime;

INT_X ApplicationStartIndex;

INT_X ApplicationRunTime;

INT_X FlashEraseModeIndex;

INT_X FlashReadModeIndex;

INT_X FlashLockBits;

INT_X UnlockDebugBit;

INT_X LockBitsEn;

INT_X VerifyModeIndex;

INT_X IEEEAddeModeIndex;

INT_X ManIEEEAddeModeIndex;

INT_X BeepOKEn;

INT_X VccIndex;

INT_X TargetEnMask; //used in the GangPro-CC only

INT_X RetainDataEn;

INT_X RetainDataStartAddr;

INT_X RetainDataStopAddr;

INT_X EraseDefBlock1En;

INT_X EraseDefBlock1StartAddr;

INT_X EraseDefBlock1StopAddr;

INT_X EraseDefBlock2En;

INT_X EraseDefBlock2StartAddr;

INT_X EraseDefBlock2StopAddr;

INT_X EraseDefBlock3En;

INT_X EraseDefBlock3StartAddr;

INT_X EraseDefBlock3StopAddr;

INT_X EraseDefBlock4En;

INT_X EraseDefBlock4StartAddr;

Page 44: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 44

INT_X EraseDefBlock4StopAddr;

INT_X ReadDefBlock1En;

INT_X ReadDefBlock1StartAddr;

INT_X ReadDefBlock1StopAddr;

INT_X ReadDefBlock2En;

INT_X ReadDefBlock2StartAddr;

INT_X ReadDefBlock2StopAddr;

INT_X ReadDefBlock3En;

INT_X ReadDefBlock3StartAddr;

INT_X ReadDefBlock3StopAddr;

INT_X ReadDefBlock4En;

INT_X ReadDefBlock4StartAddr;

INT_X ReadDefBlock4StopAddr;

INT_X Spare1;

INT_X Spare2;

INT_X Spare3;

INT_X Spare4;

INT_X Spare5;

INT_X Spare6;

INT_X Spare7;

INT_X Spare8;

INT_X Spare9;

INT_X Spare10;

INT_X Spare11;

INT_X Spare12;

INT_X Spare13;

INT_X Spare14;

INT_X Spare15;

INT_X Spare16;

} CFG_BLOCK;

Syntax: MSPPRG_API INT_X F_ConfigSetup( CFG_BLOCK config );

Return value:

0 - FALSE

1 - TRUE

Example:

Example below shows the method of modification of the programmers configuration setup. First

the current setup from the programmer is uploaded to the application, after that some of the

parameters have been modified and at the end the modified setup is returned back to the

programmer.

CFG_BLOCK config; //programmer’s configuration data

.......................

Page 45: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 45

F_GetSetup( &config );

//API-DLL - get configuration from the programmer

config.CommSpeedIndex = SPEED_3MB_INDEX;

//select JTAG interface

config.FlashEraseModeIndex = ERASE_ALL_MEM_INDEX;

//select all memory erase option

F_ConfigSetup( config );

//API-DLL - setup configuration in the programmer

F_SetConfig

F_SetConfig - Setup one item of the programmer’s configuration.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Similar to the F_ConfigSetup, but only one selected item from the CFG_BLOCK structure

is modified.

Syntax: MSPPRG_API INT_X F_SetConfig( INT_X index, INT_X data );

Return value:0 - FALSE

1 - TRUE

Example: .......................

.......................

F_SetConfig( CFG_MICROCONTROLLER, config.uProcIndex );

or

F_SetConfig( CFG_MICROCONTROLLER, 7 );

Index’s list

CFG_MICROCONTROLLER 1

CFG_POWERTARGETEN 2

CFG_COMM_SPEED_INDEX 3

CFG_RESET_TIME_INDEX 4

CFG_RESET_PULSE_TIME 5

CFG_RESET_IDLE_TIME 6

CFG_RSTVCC_OFF_TIME 7

CFG_APPLSTARTEN 8

CFG_APPL_RUN_TIME 9

CFG_FLASHERASEMODE 10

CFG_FLASHREADMODE 11

CFG_FLASH_LOCKBIT 12

CFG_UNLOCK_DEBUG_BIT 13

CFG_LOCK_BITS_EN 14

Page 46: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 46

CFG_VERIFYMODE 15

CFG_IEEE_ADDR_MODE 16

CFG_MAN_IEEE_ADDR_MODE 17

CFG_BEEP_OK_EN 18

CFG_VCCINDEX 19

CFG_TARGET_EN_MASK 20

CFG_RETAIN_DEF_DATA_EN 21

CFG_RETAIN_START_ADDR 22

CFG_RETAIN_STOP_ADDR 23

CFG_ERASE_DEFBLOCK1_EN 24

CFG_ERASE1_START_ADDR 25

CFG_ERASE1_STOP_ADDR 26

CFG_ERASE_DEFBLOCK2_EN 27

CFG_ERASE2_START_ADDR 28

CFG_ERASE2_STOP_ADDR 29

CFG_ERASE_DEFBLOCK3_EN 30

CFG_ERASE3_START_ADDR 31

CFG_ERASE3_STOP_ADDR 32

CFG_ERASE_DEFBLOCK4_EN 33

CFG_ERASE4_START_ADDR 34

CFG_ERASE4_STOP_ADDR 35

CFG_READ_DEFBLOCK1_EN 36

CFG_READ1_START_ADDR 37

CFG_READ1_STOP_ADDR 38

CFG_READ_DEFBLOCK2_EN 39

CFG_READ2_START_ADDR 40

CFG_READ2_STOP_ADDR 41

CFG_READ_DEFBLOCK3_EN 42

CFG_READ3_START_ADDR 43

CFG_READ3_STOP_ADDR 44

CFG_READ_DEFBLOCK4_EN 45

CFG_READ4_START_ADDR 46

CFG_READ4_STOP_ADDR 47

CFG_IEEE_ADDR_LOCATION 48

CFG_IEEE_ADDR_LOC_MODE 49

CFG_IEEE_ADDR_LSB_FIRST 50

// -------------- CONFIG_BLOCK - definitions ----

// CFG_MICROCONTROLLER 1

CC_ANY 0

// 1 - CC1110F8

// 2 - CC1110F16

// 3 - CC1110F32

// 4 - CC2430F32

// 5 - CC2430F64

Page 47: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 47

// 6 - CC2430F128

// 7 - CC2431F32

// 8 - CC2431F64

// 9 - CC2431F128

// 10 - CC2510F8

// 11 - CC2510F16

// 12 - CC2510F32

// 13 - CC2511F8

// 14 - CC2511F16

// 15 - CC2511F32

// CFG_POWERTARGETEN 2

// 0 -> PowerTarget Disable

// 1 -> PowerTarget Enable

// CFG_COMM_SPEED_INDEX 3

SPEED_3MB_INDEX 1

SPEED_1MB_INDEX 2

// CFG_RESET_TIME_INDEX 4

RESET_10MS_INDEX 0

RESET_100MS_INDEX 1

RESET_200MS_INDEX 2

RESET_500MS_INDEX 3

RESET_CUSTOM_INDEX 4

RESET_TOGGLE_VCC_INDEX 5

// CFG_RESET_PULSE_TIME 5

time in ms

// CFG_RESET_IDLE_TIME 6

time in ms

// CFG_RSTVCC_OFF_TIME 7

time in ms

// CFG_APPLSTARTEN 8

APPLICATION_KEEP_RESET 0

APPLICATION_TOGGLE_RESET 1

APPLICATION_TOGGLE_VCC 2

APPLICATION_SOFT_RESET 3

// CFG_APPL_RUN_TIME 9

time in ms

// CFG_FLASHERASEMODE 10

ERASE_NONE_MEM_INDEX 0

ERASE_ALL_MEM_INDEX 1

Page 48: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 48

ERASE_INFILE_MEM_INDEX 2

ERASE_DEF_CM_INDEX 3

// CFG_FLASHREADMODE 11

READ_ALL_MEM_INDEX 0

READ_PRGMEM_ONLY_INDEX 1

READ_INFOMEM_ONLY_INDEX 2

READ_DEF_MEM_INDEX 3

// CFG_FLASH_LOCKBIT 12

// CFG_UNLOCK_DEBUG_BIT 13

// CFG_LOCK_BITS_EN 14

// CFG_VERIFYMODE 15

VERIFY_NONE_INDEX 0

VERIFY_STD_INDEX 1

VERIFY_FAST_INDEX 2

// CFG_IEEE_ADDR_MODE 16

AP_IEEE_ADDR_DISABLE 0

AP_WR_NEW_IEEE_ADDR 1

AP_RETAIN_CODE_WR_IEEE 2

AP_IEEE_ADDR_BLANK 3

AP_RETAIN_IEEE_ADDR 4

AP_ASSIGN_WR_IEEE_ADDR 5

AP_WR_IEEE_ADDR_FROM_FILE 6

// CFG_MAN_IEEE_ADDR_MODE 17

AP_IEEE_ADDR_DISABLE 0

AP_WR_NEW_IEEE_ADDR 1

AP_RETAIN_CODE_WR_IEEE 2

// CFG_BEEP_OK_EN 18

// CFG_VCCINDEX 19

VCC_2V2_INDEX 0

VCC_2V4_INDEX 1

VCC_2V6_INDEX 2

VCC_2V8_INDEX 3

VCC_3V0_INDEX 4

VCC_3V2_INDEX 5

VCC_3V4_INDEX 6

VCC_3V6_INDEX 7

// CFG_RETAIN_DEF_DATA_EN 21

0-disable 1-enable

// CFG_RETAIN_START_ADDR 22

0x00000 to 0x1FFFF

Page 49: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 49

// CFG_RETAIN_STOP_ADDR 23

0x00000 to 0x1FFFF

// CFG_ERASE_DEFBLOCK1_EN 24

0-disable 1-enable

// CFG_ERASE1_START_ADDR 25

0x00000 to 0x1FFFF

// CFG_ERASE1_STOP_ADDR 26

0x00000 to 0x1FFFF

// CFG_ERASE_DEFBLOCK2_EN 27

0-disable 1-enable

// CFG_ERASE2_START_ADDR 28

0x00000 to 0x1FFFF

// CFG_ERASE2_STOP_ADDR 29

0x00000 to 0x1FFFF

// CFG_ERASE_DEFBLOCK3_EN 30

0-disable 1-enable

// CFG_ERASE3_START_ADDR 31

0x00000 to 0x1FFFF

// CFG_ERASE3_STOP_ADDR 32

0x00000 to 0x1FFFF

// CFG_ERASE_DEFBLOCK4_EN 33

0-disable 1-enable

// CFG_ERASE4_START_ADDR 34

0x00000 to 0x1FFFF

// CFG_ERASE4_STOP_ADDR 35

0x00000 to 0x1FFFF

// CFG_READ_DEFBLOCK1_EN 36

0-disable 1-enable

// CFG_READ1_START_ADDR 37

0x00000 to 0x1FFFF

// CFG_READ1_STOP_ADDR 38

0x00000 to 0x1FFFF

// CFG_READ_DEFBLOCK2_EN 39

Page 50: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 50

0-disable 1-enable

// CFG_READ2_START_ADDR 40

0x00000 to 0x1FFFF

// CFG_READ2_STOP_ADDR 41

0x00000 to 0x1FFFF

// CFG_READ_DEFBLOCK3_EN 42

0-disable 1-enable

// CFG_READ3_START_ADDR 43

0x00000 to 0x1FFFF

// CFG_READ3_STOP_ADDR 44

0x00000 to 0x1FFFF

// CFG_READ_DEFBLOCK4_EN 45

0-disable 1-enable

// CFG_READ4_START_ADDR 46

0x00000 to 0x1FFFF

// CFG_READ4_STOP_ADDR 47

0x00000 to 0x1FFFF

// CFG_IEEE_ADDR_LOCATION 48

0x00000 to 0x1FFF8

// CFG_IEEE_ADDR_LOC_MODE 49

0-default 1-defined

// CFG_IEEE_ADDR_LSB_FIRST 50

0-disable 1-enable

F_GetConfig

F_GetConfig - Get one item of the programmer’s configuration.

VALID FPA index - ( 1 to 8 )

Similar to the F_GetSetup, but only one item from the CFG_BLOCK structure is read.

Syntax: MSPPRG_API INT_X F_GetConfig( INT_X index );

Page 51: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 51

Index’s list - see F_SetConfig

Return value:

Requested setup parameter;

Example: .......................

.......................

F_GetSetup( config );

DeviceIndex = config.DeviceIndex;

or directly

DeviceIndex = F_GetConfig( CFG_MICROCONTROLLER );

.......................

F_DispSetup

F_DispSetup - Copy programmer’s configuration to report message buffer in text form.

VALID FPA index - ( 1 to 8 )

Syntax: MSPPRG_API INT_X F_DispSetup( void );

Return value:

1 - TRUE;

Example: .......................

.......................

F_DispSetup();

Disp_report_message();

//see F_ReportMessage or F_GetReportMessage for details

.......................

F_ReportMessage, F_Report_Message

F_ReportMessage - Get the last report message from the programmer.

or F_Report_Message

Page 52: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 52

VALID FPA index - ( 1 to 8 )

When any of the DLL functions is activated, a message is created and displayed on the

dynamically created programmer’s dialogue box. At the end of execution the dialogue box is

closed and function returns back to the application program. Reported message is closed as well.

The last report message can be read by application program using F_ReportMessage function.

When F_ReportMessage is called, then report message up to

REPORT_MESSAGE_MAX_SIZE 2000

characters is imported from the programmer software to the application software. Make sure to

declare characters string length no less then REPORT_MESSAGE_MAX_SIZE characters. When the

F_ReportMessage is called then at the end the internal report message buffer in the programmer

software is cleared. When F_ReportMessage is not called after every communication with the

target device, then the report message will collect all reported information up to

REPORT_MESSAGE_MAX_SIZE last characters.

Syntax: MSPPRG_API void F_ReportMessage( char * text );

MSPPRG_API char* F_Report_Message( void );

note: F_Report_Message is available only with the Multi-FPA API-DLL.

Return value:none

Example:#include “FlashProCC-Dll.h”;

char text[REPORT_MESSAGE_MAX_SIZE];

.......................

.......................

F_ReportMessage( text );

.......................

Example below shows how to take a message and display it in the scrolling box. The Edit box

with the ID e.g. IDC_REPORT must be created first.

............................................

#include “FlashProCC-Dll.h”;

Cstring Message = "";

............................................

Page 53: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 53

void CMspPrgDemoDlg::Disp_report_message()

{

char text[REPORT_MESSAGE_MAX_SIZE];

F_ReportMessage( text ); //API-Dll - get last report message

Message = text;

SetDlgItemText(IDC_REPORT, Message.GetBuffer(Message.GetLength()));

CEdit* pEdit = (CEdit*) GetDlgItem(IDC_REPORT);

pEdit->LineScroll(pEdit->GetLineCount(), 0);

UpdateWindow();

}

F_GetReportMessageChar

F_GetReportMessageChar - Get one character of the the last report message from the

programmer.

VALID FPA index - ( 1 to 8 )

See comment for the F_ReportMessage function.

F_GetReportMessageChar allows to get character by character from the report message buffer.

This function is useful in the Visual Basic application, where all message can not be transfered

via pointer like it is possible in the C++ application.

Syntax: MSPPRG_API char F_GetReportMessageChar( INT_X index );

Return value:Requested character from the Report Message buffer. 1 - TRUE

Example:#include “FlashProCC-Dll.h”;

char text[REPORT_MESSAGE_MAX_SIZE];

INT_X k;

.......................

.......................

for( k = 0; k< REPORT_MESSAGE_MAX_SIZE; k++ )

text[k] = F_GetReportMessageChar( k );

.......................

Example below shows how to take a message and display it in the scrolling box. The Edit box

with the ID e.g. IDC_REPORT must be created first.

Page 54: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 54

............................................

#include “FlashProCC-Dll.h”;

Cstring Message = "";

............................................

void CMspPrgDemoDlg::Disp_report_message()

{

char text[REPORT_MESSAGE_MAX_SIZE];

INT_X k;

for( k = 0; k< REPORT_MESSAGE_MAX_SIZE; k++ )

text[k] = F_GetReportMessageChar( k );

Message = text;

SetDlgItemText(IDC_REPORT, Message.GetBuffer(Message.GetLength()));

CEdit* pEdit = (CEdit*) GetDlgItem(IDC_REPORT);

pEdit->LineScroll(pEdit->GetLineCount(), 0);

UpdateWindow();

}

F_ReadCodeFile, F_Read_CodeFile

F_ReadCodeFile - Read code data from the file and download it to internal buffer.

or F_Read_CodeFile

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Function F_ReadCodeFile downloads code from the file to internal memory buffer. Code file

format and file name and location path of the desired file must be specified. Three file formats

are supported - Texas Instruments text format, Motorola *.s19 format and Intel *.hex format.

When file is downloaded then contents of this file is analysed. Only code memory location valid

for the Ccxx device family will be downloaded to the internal memory buffer. Any code data

located outside memory space of the Ccxx device will be ignored and warning message will be

created.

Syntax: MSPPRG_API INT_X F_ReadCodeFile( int file_format, char * FileName );

MSPPRG_API INT_X F_Read_CodeFile( int file_format, CString FileName );

file_format:

FILE_TI_FORMAT (1) for TI (*.txt) format

FILE_MOTOROLA_FORMAT (2) for Motorola (*.s19, *.s28 or *.s37)

FILE_INTEL_FORMAT (3) for Intel (*.hex)

FileName: file name including path, file name and extention

Page 55: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 55

Return value:(0xFFFe & info) | state

where state is defined as follows:

0 - FALSE

1 - TRUE

info is defined as follows:

warning -> CODE_IN_ROM

CODE_IN_RAM

CODE_OUT_OF_FLASH

CODE_OVERWRITTEN

error -> INVALID_CODE_FILE

OPEN_FILE_OR_READ_ERR

Example:

int st;

....................

st = F_ReadCodeFile( FILE_TI_FORMAT, “c:\test\demofile.txt” );

if(( st & 1 ) == TRUE )

{

....................

}

else

{

if ( st & CODE_IN_ROM ) {......}

if ( st & CODE_OUT_OF_FLASH ) {......}

if ( st & INVALID_CODE_FILE ) {......}

if ( st & OPEN_FILE_OR_READ_ERR ) {......}

....................

....................

}

F_Get_CodeCS

F_Get_CodeCS - Read code from internal buffer and calculate the check sum.

VALID FPA index - ( 1 to 8 ).

Syntax: MSPPRG_API INT_X F_Get_CodeCS( int index );

index - index of the desired code

Index = 1 - Calculate check sum of the code from internal code buffer.

Page 56: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 56

Other Index values - reserved for the future option.

Check Sum is calculated as an arithmetic sum of the 16-bits unsigned words form the valid code

bytes. If the only one byte is present in the calculated word, then other byte is taken as a 0xFF.

Check Sum result is 32 bits.

For example from the following code

address data

0x0300 0xF2 0x12 0x23 0x34 0x78

Check Sum calculation

Word 1 0x12F2

Word 2 0x3423

Word 2 0xFF78

---------------------------------

CS = 0x0001468D

Return value:

Calculated check sum.

F_ConfigFileLoad, F_Config_FileLoad

F_ConfigFileLoad - Modify programmer’s configuration setup according to data taken

or F_Config_FileLoad from the specified configuration file.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

The F_ConfigFileLoad function can download the programmer setup from the external setup

file. Setup file can be created using standard FlashPro-CC (GUI) Flash Programmer software.

When the setup from the file is downloaded, then old configuration setup is overwritten. The

new setup can be modified using F_GetSetup and F_ConfigSetup functions.

Location path and file name of the config file must be specified.

Syntax:

MSPPRG_API INT_X F_ConfigFileLoad( char * filename );

MSPPRG_API INT_X F_ConfigFileLoad( Cstring filename );

Page 57: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 57

filename - configuration file name including path, file name and extention

Return value:0 - FALSE

1 - TRUE

(0xFFFe & info) | state

where state is defined as follows:

0 - FALSE

1 - TRUE

info is defined as follows:

error -> OPEN_FILE_OR_READ_ERR

Configuration file is a standard text file with the parameters name and value.

Example:st = F_ConfigFileLoad( “c:\test\configfile.cfg” );

if(( st & 1 ) == TRUE )

{

....................

}

else

{

Info = st & 0xFFFE;

....................

}

F_Clr_Code_Buffer

F_Clr_Code_Buffer - Clear content of the code buffer.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Syntax: MSPPRG_API INT_X F_Clr_Code_Buffer( void );

Return value:0 - FALSE

1 - TRUE

Example:.....................

F_Clr_Code_Buffer();

.....................

Page 58: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 58

F_Put_Byte_to_Code_Buffer

F_Put_Byte_to_Code_Buffer - Write code data to code buffer.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Instruction allows to write contents of the code to code buffer instead using the F_ReadCodeFile

instruction. Contents of the downloaded code data can be modified or filled with the new data, if

code buffer has been cleared first (using F_Clr_Code_Buffer function).

Syntax: MSPPRG_API INT_X F_Put_Byte_to_Code_Buffer( INT_X address, BYTE data );

Parameters value:code address - 0x0 to 0x1FFFF

data - 0x00 to 0xFF

Return value:0 - FALSE

1 - TRUE

Example:

BYTE code[MAX_FLASH_SIZE];

.....................

F_Clr_Code_Buffer();

for( address = 0x0; address < MAX_FLASH_SIZE; address ++ )

{

F_Put_Byte_to_Code_Buffer( address, code[address]);

}

.....................

F_Get_Byte_from_Code_Buffer

F_Get_Byte_from_Code_Buffer - Read code data from code buffer.

VALID FPA index - ( 1 to 8 )

Instruction allows to read or verify contents of the code from code buffer

Syntax: MSPPRG_API INT_X F_Get_Byte_from_Code_Buffer( INT_X address );

Page 59: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 59

Parameters value:code address - 0x0 to MAX_FLASH_SIZE-1 (0x1FFFF)

Return value:0x00 to 0xFF - valid code data

-1 (0xFFFF) - code data not initialized on particular address

F_Put_IEEEAddr64_to_Buffer

F_Put_IEEEAddr64_to_Buffer - Write IEEE address to buffer.

VALID FPA index - ( 1 to 8 ).

Instruction allows to write one unique IEEE address to buffer. Contents of the IEEE address from

the buffers will be saved to target device when the F_Autoprogram(0) is executed and when in

the configuration setup this option is enabled.

Syntax:MSPPRG_API void F_Put_IEEEAddr64_to_Buffer(ULONG64 data );

Parameters value: data - 64 bits unsigned long integer number 0 to 0xFFFFFFFFFFFFFFFF

F_Put_IEEEAddr_Byte_to_Buffer

F_Put_IEEEAddr_Byte_to_Buffer - Write one byte of the IEEE address to buffer.

VALID FPA index - ( 1 to 8 ).

Instruction allows to write one byte of the unique IEEE address to buffer. Contents of the IEEE

address from the buffers will be saved to target device when the F_Autoprogram(0) is executed

and when in the configuration setup this option is enabled.

Syntax:MSPPRG_API INT_X F_Put_IEEEAddr64_to_Buffer( BYTE no, BYTE data );

Page 60: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 60

Instruction is functionally the same as the F_Put_IEEEAddr64_to_Buffer, but allows to transfer

byte by byte of the 64 IEEE address to buffer. Function is used when the Visual Basic 6 is used,

that not support the Int 64 bits data.

no -> 0 to 7.

Index no MUST started from 0 and finished on 7 to transfer whole IEEEAddr. When no = 0, the

lowest byte of the IEEEAddr must be transferred. When no = 7, the highest byte of the

IEEEAddr is transferred.

Parameters value: data - one byte from 64 bits IEEEAddr data

F_Get_IEEEAddr64_from_Buffer

F_Get_IEEEEAddr64_from_Buffer - Read IEEE address contents from the buffer

VALID FPA index - ( 1 to 8 )

Syntax: MSPPRG_API ULONG64 F_Get_IEEEAddr64_from_Buffer(BYTE no,);

Parameters value:none

Return value:64 bits unsigned long integer number 0 to 0xFFFFFFFFFFFFFFFF

F_Get_IEEEAddr_Byte_from_Buffer

F_Get_IEEEEAddr_Byte_from_Buffer - Read one byte of the IEEE address contents from

the buffer

VALID FPA index - ( 1 to 8 )

Syntax: MSPPRG_API BYTE F_Get_IEEEAddr_Byte_from_Buffer();

Instruction is functionally the same as the F_Get_IEEEAddr64_from_Buffer, but allows to

transfer byte by byte of the 64 IEEE address from buffer. Function is used when the Visual Basic

6 is used, that not support the Int 64 bits data.

no -> 0 to 7.

Page 61: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 61

When no = 0, the lowest byte of the IEEEAddr is transferred. When no = 7, the highest byte of

the IEEEAddr is transferred.

Parameters value:no - byte number of the 64 bits IEEEAddr data

Return value:one byte of the IEEEAddr

F_Power_Target

F_Power_Target - Turn ON or OFF power from programming adapter to target

device.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Function F_Power_Target switches ON or OFF power from the programming adapter to the target

device.

Note: PowerTargetEn flag must be set to TRUE (1) in the configuration setup to switch the

power from the programming adapter ON.

Syntax: MSPPRG_API INT_X F_Power_Target( INT_X OnOff );

Return value:0 - FALSE

1 - TRUE

Example:.....................

F_Power_Target( 1 ); // Turn Power ON

.....................

F_Power_Target( 0 ); // Turn Power OFF

.....................

F_Reset_Target

F_Reset_Target - Generate short RESET pulse on the target’s device RESET line.

Page 62: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 62

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Function F_Reset_Target resets target device and target device’s application program can start.

Length of the RESET pulse time is specified by ResetTimeIndex in configuration setup. See

F_ConfigSetup description for details.

Syntax: MSPPRG_API INT_X F_Reset_Target( void );

Return value:0 - FALSE

1 - TRUE

Example:.....................

F_Reset_Target( void );

.....................

F_Get_Targets_Vcc

F_Get_Targets_Vcc - Get Vcc in [mV] supplied target device.

VALID FPA index - ( 1 to 8 )

Syntax: MSPPRG_API INT_X F_Get_Targets_Vcc( void );

Return value:INT_X - Vcc in milivolts e.g 3000 -> 3.0 V

or (-1) if USB-FPA is not active.

Page 63: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 63

4.3 Encapsulated instructions

Encapsulated functions are powerful and easy to use. When called then all device actions from the

beginning to the end are done automatically and final result is reported as TRUE or FALSE.

Required configuration should be set first using F_GetSetup and F_ConfigSetup functions.

Encapsulated function has following sequence:

- Power from the programming adapter becomes ON if PowerTargetEn in configuration

setup is enabled.

- Vcc is verified to be higher then 2.0V.

- Communication between programming adapter and target device is initialized.

- Selected encapsulated instruction is executed ( Autoprogram, Memory Erase etc. ).

- Communication between target device and programming adapter is terminated.

- Power from the programming adapter becomes OFF (if selected).

- Target device is released from the programming adapter.

F_AutoProgram

F_AutoProgram - Target device program with full sequence - erase, blank check,

program, verify and blow security fuse (if enabled).

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed simultaneously.

Auto Program button is the most frequently function when programming microcontrollers in

the production process. Auto Program function activates all required procedures to fully program and

verify the flash memory contents. Typically, when flash memory needs to be erased, Auto Program

executes the following procedures:

- initialization

- read retained data (if required)

- read IEEE address contents(if required)

- erase flash memory,

- memory blank check,

- flash programming,

- restoring or writing the new IEEE address (if required)

- restoring retained data (if required)

- flash memory verification (check sum verification of whole verification byte by byte),

- write lock protection bits (if required).

- switch-off Vcc from target device.

Page 64: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 64

Syntax: MSPPRG_API INT_X F_AutoProgram( INT_X mode );

mode = 0;

mode = 1 and up - reserved

Return value:0 - FALSE

1 - TRUE

Example: ............................

if( F_Initialization() != TRUE ) //required API-Dll - initialization

{

// Initialization error

}

F_GetSetup( &config ); //API-DLL - get configuration from the programmer

............................ // modify configuration if required

F_ConfigSetup( config ); // download setup to programmer

int st = F_ConfigFileLoad( “c:\test\configfile.cfg” );

if(( st & 1 ) != TRUE )

{

Info = st & 0xFFFE;

....................

}

do{

.................... // prepare next microcontrollers

targets_mask = 0x3F //active all six target devices

F_SetConfig( CFG_TARGET_EN_INDEX, (INT_X)targets_mask );

if( F_AutoProgram(0) == targets_mask )

{

//all target devices programmed

}

else

{

//some targets has nod been programmed

}

.................... //exit if the last microcontrollers

// has been programmed

} while(1); ....................

F_Verify_Lock_Bits

Page 65: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 65

F_Verify_Lock_Bits -Verify the Lock debug Bit. If debug access is disabled, then only

debug bit is verified. Other bits are not accessible when the debug bit

enable is clear.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed simultaneously.

Lock Protection bits

bit-4 0x10 - Boot Block Lock

0 - Page 0 is write protected

1 - Page 0 is writable, unless LSIZE is 000

bits3:1 LSIZE - Sets the size of the upper Flash area which is write-protected

bit 0 0x01 Debug lock bit

0 - Disable debug command

1 - Enable debug command

Syntax: MSPPRG_API INT_X F_Verify_Lock_Bits( void );

Return value:0x100 | 8 bits Lock Bits value (see above)

if debug bit is enabled or

0x100

if debug bit is disabled (access to other bits is locked)

F_Memory_Erase

F_Memory_Erase - Erase Target’s Flash Memory

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed simultaneously.

Erase flash size, or sector to be erased, should be specified in the configuration setup. When mode

erase flag is set to one, then all memory will be erased, regardless erase memory configuration setup

value.

Syntax: MSPPRG_API INT_X F_Memory_Erase( INT_X mode );

mode = 0 -> erase space specify by the FlashEraseModeIndex;

mode = 1 -> erase all Flash memory, regardless FlashEraseModeIndex;

Return value:

Page 66: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 66

0 - FALSE

1 - TRUE

F_Memory_Blank_Check

F_Memory_Blank_Check - Check if the Target’s Flash Memory is blank.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed simultaneously.

Syntax: MSPPRG_API INT_X F_Memory_Blank_Check( void );

Return value:0 - FALSE

1 - TRUE

F_Memory_Write

F_Memory_Write - Write content taken from the Code file to the selected Target

Devices Flash Memory.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed simultaneously.

Syntax: MSPPRG_API INT_X F_Memory_Write( INT_X mode );

mode = 0;

mode = 1 and up - reserved

Return value:0 - FALSE

1 - TRUE

F_Memory_Verify

F_Memory_Verify - Verify contents of the selected Target Devices Flash Memory and

Code file.

Page 67: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 67

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed simultaneously.

Note: During the verification process either all memory or just the selected part of the memory is

verified, depending on settings specified in the configuration setup FlashEraseModeIndex.

Only data taken from the Code file are compared with the target’s flash memory. If size of the

flash memory is bigger then code size then all reminding data in flash memory is ignored.

Syntax: MSPPRG_API INT_X F_Memory_Verify( INT_X mode );

mode = 0;

mode = 1 and up - reserved

Return value:0 - FALSE

1 - TRUE

F_Memory_Read

F_Memory_Read - Read Flash Memory from selected or all Target Devices.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed simultaneously.

Size of the read memory size is defined in the configuration setup

All data will be saved in the internal Read Buffer. Contents from the Read Buffer can be taken using

function

BYTE F_Get_Byte_from_Buffer( INT_X addr );

Syntax: MSPPRG_API INT_X F_Memory_Read( void );

Return value:0 - FALSE

1 - TRUE

Example: BYTE data[MAX_FLASH_SIZE];

unsigned int addr,n;

....................

st = F_Memory_Read();

if ( st != 0 )

Page 68: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 68

{

for( addr=0x0; addr<MAX_FLASH_SIZE; addr++)

data[addr] = F_Get_Byte_from_Buffer( addr );

}

....................

F_Write_IEEE_Address

F_Write_IEEE_Address - Write content taken from the IEEE Address buffer to target

devices. Write IEEE address option should be enabled in the

configuration setup.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed simultaneously.

Syntax:INT_X MSPPRG_API F_Write_IEEE_Address( void );

Return value:0 - FALSE

1 - TRUE

Example:

F_Put_IEEEAddr64_to_Buffer( 0x0123456789ABCDE0 );

F_Write_IEEE_Address();

F_Read_IEEE_Address

F_Read_IEEE_Address - Read IEEE Addresses from target devices and save it in the

IEEE buffer

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed simultaneously.

Syntax:INT_X MSPPRG_API F_Read_IEEE_Address( void );

Page 69: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 69

Return value:0 - FALSE

1 - TRUE

Example:#define “FlashProCC-Dll.h”;

ULONG64 IEEE;

F_Read_IEEE_Address();

IEEE = F_Get_IEEEAddr64_from_Buffer();

F_Write_Lock_Bits

F_Write_Lock_Bits - Write lock bits to target devices. Contents of the lock bits should be

set first using configuration setup instructions.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Syntax:

MSPPRG_API INT_X F_Write_Lock_Bits( void );

Return value:

0 - FALSE

1 - TRUE

Page 70: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 70

4.4 Sequential instructions

Sequential instructions allow access to the target device in any combination of the small

instructions like erase, read, write sector, modify part of memory etc. Sequential instruction have an

access only when communication between target device and programming adapter is initialized. This

can be done when F_Open_Target_Device instruction is called. When communication is established,

then any of the sequential instruction can be called. When the process is finished, then at the end

F_Close_Target_Device instruction should be called. When communication is terminated, then

sequential instructions can not be executed.

Note: Erase/Write/Verify/Read configuration setup is not required when sequential instructions are

called. Also code file is not required to be downloaded. All data to be written, erased, and read is

specified as a parameter to the sequential functions. Data downloaded from the code file is ignored

in this case.

Very important:

The sequential functions allows to program words in the FLASH memory on any flash space location.

Also the same bytes / words can be programmed few times. Software is not be able to control how

many times the same location of the flash has been programmed between erasures. User should take

a full responsibility for programming the flash memory according to the CCxx specifications. See TI’s

data sheets and manuals for details.

The following flash programming limitation should be taken to consideration:

1. The same word or byte can not be programmed more then twice between erasures. Otherwise,

damage can occur.

2. In the CCxx flash device two or four bytes are programmed simultaneously. This means -

programmed bytes should be prepared first and flashed as a block with two or four bytes

length. Otherwise four independent bytes programmed separately will be programmed four

times - one time with required data and 3 times with 0xFF data.

Note: CCxx devices with max flash size up to 32 kB have two bytes size programming word

in the flash, while the CCxx with bigger flash memory size (up to 128 kB), have four bytes size

writing word.

Page 71: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 71

F_Open_Target_Device

F_Open_Target_Device - Initialization communication with the target device.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed simultaneously.

When F_Open_Target_Device is executed, then

- Power from the programming adapter becomes ON if PowerTargetEn in configuration

setup is enabled.

- Vcc is verified to be higher then 2.0V.

- communication between programming adapter and target device is initialized.

Target device is ready to get other sequential instructions.

Syntax: MSPPRG_API INT_X F_Open_Target_Device( void );

Return value:0 - FALSE

1 - TRUE

Example: int st, mask;

long addr;

....................

mask = 0x3F; //enable all six target devices

F_SetConfig( CFG_TARGET_EN_INDEX, (INT_X)mask );

F_Open_Target_Device();

....................

F_Segment_Erase(0x1000);

st = F_Sectors_Blank_Check( 0x1000, 0x107f );

if( st != mask )

{ ................ }

for( addr = 0x1000; addr<0x1020; addr++ )

F_Put_Byte_to_Buffer( addr, data(addr) )

F_Copy_Buffer_to_Flash( 0x1000, 0x20 );

F_Segment_Erase(0x4000);

....................

F_Close_Target_Device();

....................

F_Close_Target_Device

Page 72: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 72

F_Close_Target_Device - Termination communication between target device and programming

adapter.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Instruction should be called on the end of the sequential instructions. When F_Close_Target_Device

instruction is executed then:

- Communication between target device and programming adapter is terminated.

- Power from the programming adapter becomes OFF (if selected).

- Target device is released from the programming adapter.

Syntax: MSPPRG_API INT_X F_Close_Target_Device( void );

Return value:0 - FALSE

1 - TRUE

Example:

See example above (F_Open_Target_Device).

F_Segment_Erase

F_Segment_Erase - Erase any segment of the CCxx Flash memory.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Parameters:

segment address - Any address form the desired segment space addresses

To erase a memory segment specify an address within that memory segment. For example to erase

segment 0x2000-0x27FF any address from the range 0x2000 to 0x27FF can be specified. To erase

all memory segments, erase the memory segment by segment, or used the encapsulated instruction F_Memory_Erase(1);

Note: When encapsulated instruction is executed, then next access to the sequential instruction can

be accessed only when F_Open_Target_Device instruction is called again.

Syntax:

Page 73: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 73

MSPPRG_API INT_X F_Segment_Erase( INT_X address );

Return value:0 - FALSE

1 - TRUE

Example: ....................

F_Segment_Erase(0x4000); // erase segment 0x4000 to 0x47FF

F_Segment_Erase(0x4100); // erase the same segment

....................

F_Sectors_Blank_Check

F_Sectors_Blank_Check - Blank check part or all Flash Memory. Start and stop address of the

tested memory should be specified.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Parameters:

start address - Even number from 0x0 to 0x1FFFE,

stop address - Odd number from 0x1 to 0x1FFFF,,

Syntax: MSPPRG_API INT_X F_Sectors_Blank_Check( INT_X start_addr,

INT_X stop_addr );

Return value:0 - FALSE

1 - TRUE

Example: ....................

F_Sectors_Blank_Check (0x1000, 0x107F) ; //INFO secto blank check

F_Sectors_Blank_Check (0x8000, 0xFFFF) ; //32 kB memory size blank check

F_Sectors_Blank_Check (0x1220, 0x123f) ; //part of sector blank check

....................

F_Write_Byte_to_XRAM

Page 74: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 74

F_Write_Byte_to_XRAM - Write one byte to XRAM.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs).

Write one byte to any XRAM location of the target devices.

Parameters:

address - address where XRAM is located 0xDF00 to 0xFFFF,

data - one byte to be written to target device

Syntax: MSPPRG_API INT_X F_Write_Byte_to_XRAM( INT_X addr, BYTE data );

Return value:0 - FALSE

1 - TRUE

Example:F_Write_Byte_to_XRAM( 0xF010, 0x21 );

F_Read_Byte_from_XRAM

F_Read_Byte_from_XRAM - Reade one byte from XRAM.

VALID FPA index - ( 1 to 8 ).

Read one byte from any XRAM location of the target devices.

Parameters:

address - address where XRAM is located 0xDF00 to 0xFFFF,

data - one byte to be written to target device

Syntax: MSPPRG_API INT_X F_Read_Byte_from_XRAM( INT_X addr );

Return value:0x00 to 0xFF - valid code data

-1 (0xFFFF) - FALSE

Example:F_Read_Byte_from_XRAM( 0xF010 );

Page 75: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 75

F_Write_Byte_to_direct_RAM

F_Write_Byte_to_direct_RAM - Write one byte to direct RAM.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Write one byte to any direct RAM location of the target devices.

Parameters:

address - address where RAM is located 0x00 to 0xFF,

data - one byte to be written to target device

Syntax: MSPPRG_API INT_X F_Write_Byte_to_direct_RAM( INT_X addr, BYTE data );

Return value:0 - FALSE

1 - TRUE

Example:F_Write_Byte_to_direct_RAM( 0x60, 0x33 );

F_Read_Byte_from_direct_RAM

F_Read_Byte_from_direct_RAM - Read one byte from direct RAM.

VALID FPA index - ( 1 to 8 ).

Read one byte from any direct RAM location of the target devices.

Parameters:

address - address where RAM is located 0x00 to 0xFF,

data - one byte to be written to target device

Syntax: MSPPRG_API INT_X F_Read_Byte_from_direct_RAM( INT_X addr );

Return value:

Page 76: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 76

0x00 to 0xFF - valid code data

-1 (0xFFFF) - FALSE

Example:F_Read_Byte_from_direct_RAM( 0x60 );

F_Copy_Buffer_to_Flash

F_Copy_Buffer_to_Flash - Write data from the Buffer to target devices.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Parameters:

start address - Flash address from 0x0 to 0x1FFFF,

size - Size from 1 to MAX_FLASH_SIZE (0x20000) - block of data in bytes

to be written.

Syntax: MSPPRG_API INT_X F_Copy_Buffer_to_Flash( INT_X start_addr, INT_X size );

Return value:0 - FALSE

1 - TRUE

Example: long addr;

int mask;

....................

for( addr = 0x1000; addr<0x2100; addr++ )

F_Put_Byte_to_Buffer( addr, (BYTE)(0xFF & addr));

....................

mask = 0x3F; //enable all six target devices

F_SetConfig( CFG_TARGET_EN_INDEX, (INT_X)mask );

F_Open_Target_Device();

F_Copy_Buffer_to_Flash( 0x1000, 0x1100 );

....................

F_Copy_Flash_to_Buffer

Page 77: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 77

F_Copy_Flash_to_Buffer - Read specified in “size” number of bytes from Flash and save it in

the temporary buffer. Starting address is specified in the “start

address”.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Syntax: MSPPRG_API INT_X F_Copy_Flash_to_Buffer( INT_X start_address,

INT_X size );

Parameters:start address

size

Return value:0 - FALSE

1 - TRUE

NOTE: Specified address in the temporary RAM/Flash buffer is the same as a physical RAM

address.

Example:

....................

....................

st = F_Copy_Flash_to_Buffer( 0x2220, 0xE0 );

if( st == TRUE )

{

for( addr = 0x2220; addr<0x2300; addr++ )

data[addr]= F_Get_Byte_from_Buffer( addr );

}

else

{

...................

}

....................

F_Copy_Buffer_to_XRAM

F_Copy_Buffer_to_XRAM - Write “size” number of bytes from the temporary

XRAM/Flash buffer to XRAM. Starting address is specified

in the “start address”.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Syntax:

Page 78: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 78

MSPPRG_API INT_X F_Copy_Buffer_to_XRAM( INT_X start_address, INT_X size );

Parameters:start address - physical XRAM address 0xDF00 to 0xFFFF

size - size in bytes

Return value:0 - FALSE

1 - TRUE

NOTE: Specified address in the temporary XRAM/Flash buffer is the same as a physical

XRAM address.

Example: ....................

....................

for( addr = 0xF220; addr<0xF300; addr++ )

st = F_Put_Byte_To_Buffer( addr, data[addr] );

st = F_Copy_Buffer_to_XRAM( 0xF220, 0xE0 );

....................

F_Copy_XRAM_to_Buffer

F_Copy_XRAM_to_Buffer - Read specified in “size” number of bytes from the XRAM and save

it in the temporary buffer. Starting address is specified in the “start

address”.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Syntax:

MSPPRG_API INT_X F_Copy_XRAM_to_Buffer( INT_X start_address,

INT_X size );

Parameters:start address - physical XRAM address 0xDF00 to 0xFFFF

size - size in bytes

Return value:0 - FALSE

1 - TRUE

Page 79: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 79

NOTE: Specified address in the temporary XRAM/Flash buffer is the same as a physical

XRAM address.

Example: ....................

....................

st = F_Copy_XRAM_to_Buffer( 0xF220, 0xE0 );

if( st == TRUE )

{

for( addr = 0xF220; addr<0xF300; addr++ )

data[addr]= F_Get_Byte_from_Buffer( addr );

}

else

{

...................

}

....................

F_Copy_Buffer_to_direct_RAM

F_Copy_Buffer_to_direct_RAM - Write “size” number of bytes from the temporary

XRAM/Flash buffer no ‘1' to direct RAM. Starting

address is specified in the “start address”.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Syntax:

MSPPRG_API INT_X

F_Copy_Buffer_to_direct_RAM( INT_X start_address, INT_X size );

Parameters:

start address - direct RAM address 0x00 to 0xFF

size - size in bytes

Return value:

0 - FALSE

1 - TRUE

Example:

....................

....................

Page 80: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 80

for( addr = 0x60; addr<0x7f; addr++ )

st = F_Put_Byte_To_Buffer( addr, data[addr] );

st = F_Copy_Buffer_to_direct_RAM( 0x60, 0x20 );

....................

F_Copy_direct_RAM_to_Buffer

F_Copy_direct_RAM_to_Buffer - Read specified in “size” number of bytes from the direct

RAM and save it in the temporary buffer. Starting address is

specified in the “start address”.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Syntax: MSPPRG_API INT_X

F_Copy_direct_RAM_to_Buffer( INT_X start_address, INT_X size );

Parameters:start address - direct RAM address 0x00 to 0xFF

size - size in bytes

Return value:0 - FALSE

1 - TRUE

F_Put_Byte_to_Buffer

F_Put_Byte_to_Buffer - Write byte to temporary buffer.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Syntax: MSPPRG_API INT_X F_Put_Byte_to_Buffer( INT_X address, BYTE data );

address: temporary buffer address equal the RAM/XRAM or Flash

destination address ( 0x0000 to 0x1FFFF )

data: Byte to be written.

Return value:TRUE if specified address is legal (0x0000 to 0x1FFFF) otherwise FALSE.

NOTE: Specified address in the temporary RAM or Flash buffer is the same as a physical

RAM/FLASH address.

Page 81: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 81

NOTE: DLL contains two Buffers - one is dedicated to the data READ from target devices,

second one is dedicated to the data to be WRITE to the target devices. Contents of

the Buffers can not be verified by writing and read the same data to the Buffers e.g.

F_Put_Byte_to_Buffer (0x1000, 5);

data = F_Get_Byte_from_Buffer( 0x1000 );

Read data can be other that ‘5'.

Example: ....................

....................

for( addr = 0x1000; addr<0x1020; addr++ )

st = F_Put_Byte_to_Buffer( addr, data[addr][n] );

st = F_Copy_Buffer_to_Flash( 0x1000, 0x20 );

....................

F_Get_Byte_from_Buffer

F_Get_Byte_from_Buffer - Read one byte from the temporary RAM/Flash buffer.

VALID FPA index - ( 1 to 8 )

Syntax: MSPPRG_API BYTE F_Get_Byte_from_Buffer( INT_X address );

Return value:Requested byte from the specified address of the RAM/Flash temporary

buffer.

Example:

see F_Copy_All_Flash_To_Buffer.

NOTE: DLL contains two Buffers - one is dedicated to the data READ from target devices,

second one is dedicated to the data to be WRITE to the target devices. Contents of

the Buffers can not be verified by writing and read the same data to the Buffers.

F_Set_PC_and_RUN

Page 82: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 82

F_Set_PC_and_RUN - Instructions allows to run program in microcontroller from specified

PC in the XRAM or Flash location. Program should be downloaded

first using the Write to Flash or XRAM procedures.

Note: The F_Open_Target_Device instruction is resetting the CPU. All internal registers states

are set to default value. The F_Synch_CPU_JTAG is synchronizing the CPU and JTAG on

fly. The CPU is stopped, but all registers have not been modified.

VALID FPA index - ( 1 to 8 ) or 0 (ALL FPAs) executed sequentially.

Syntax:

MSPPRG_API INT_X F_Set_PC_and_RUN( INT_X xram_en, INT_X PC_address );

Parameters:xram_en - 0 -> run program located in Flash

- 1 -> run program located in XRAM

address - set Program Counter to address and run

Return value:

0 - FALSE

1 - TRUE

F_Get_MCU_Data

F_Get_MCU_Data - Get the MCU status or device ID/silicon version

VALID FPA index - ( 1 to 8 ).

INT_X MSPPRG_API F_Get_MCU_Data( INT_X Type );

Parameters:Type: GET_MCU_ID ( 1 )

Result

Higher byte (bits 15:8) MCU ID

0x01 - CC1110F8

0x85 - CC2430F64

0x89 - CC2431F32

0x81 - CC2510F8

0x91 - CC2511F8

Lower byte (bits 15:8) Silicon version ID

GET_MCU_STATUS ( 2 )

Result one byte

0x80 - Chip Erase Done

Page 83: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 83

0x40 - PCON Idle

0x20 - CPU halted

0x10 - Power Mode 0

0x08 - Halt Status

0x04 - Debug Locked

0x02 - Oscillator stable

0x01 - Stack overflow

Return value:data from the MCU buffer.

Page 84: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 84

Appendix A

FlashPro-CC Command Line interpreter

The Multi-FPA API-DLL can be used with the command line interpreter shell. This shell allows to

use the standard Command Prompt windows or script file to execute the API-DLL functions. All

required files are located in the directory

C:\Program Files\Elprotronic\CCxx\USB FlashPro-CC\CMD-line

and contains

FP-CC-commandline.exe -> command line shell interpreter

FlashProCC-FPAsel.dll -> standard API-DLL files

FlashProCC-FPA1.dll -> ----,,,,,--------

All API-DLL files should be located in the same directory where the FP-CC-commandline.exe is

located. To start the command line interpreter, the FP-CC-commandline.exe should be executed.

Command Syntax:

instruction_name ( parameter1, parameter2, .... )

parameter:

1. string ( file name etc. ) - "filename"

2. numbers

integer decimal eg. 24

or integer hex eg. 0x18

Note: Spaces are ignored

Instructions are not case sensitive

F_OpenInstancesAndFPAs( "*# *" )

and f_openinstancesandfpas( "*# *" )

are the same.

Example-1:

Page 85: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 85

Run the FP-CC-commandline.exe

Type:

F_OpenInstancesAndFPAs( "*# *" ) // open instances and find the first adapter (any SN)

Press ENTER - result ->1 (OK)

Type:

F_Initialization() //initialization with config taken from the config.ini

//setup taken from the FlashPro-CC - with defined CCxx type, code file etc.

Press ENTER - result ->1 (OK)

Type:

F_AutoProgram( 0 )

Press ENTER - result ->1 (OK )

Type:

F_Report_Message()

Press ENTER - result -> displayed the last report message (from the F_Autoprogram(0))

See figure A-1 for result:

Type quit() and press ENTER to close the FP-CC-commandline.exe program.

Figure A-1

Page 86: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 86

Example-2:

Run the FP-CC-commandline.exe and type the following commands:

F_OpenInstancesAndFPAs( "*# *" ) // open instances and find the first adapter (any SN)

F_Initialization()

F_Report_Message()

F_ConfigFileLoad( "filename" ) //put vaild path and config file name

F_ReadCodeFile( 1, "FileName" ) //put vaild path and code file name (TI.txt format)

F_AutoProgram( 0 )

F_Report_Message()

........................

........................

F_Put_Byte_to_Buffer( 1, 0x8000, 0x11 )

F_Put_Byte_to_Buffer( 1, 0x8001, 0x21 )

........................

F_Put_Byte_to_Buffer( 1, 0x801F, 0xA6 )

F_Open_Target_Device()

F_Segment_Erase( 0x8000 )

F_Copy_Buffer_to_Flash( 0x8000, 0x20 )

F_Copy_Flash_to_Buffer( 0x8000, 0x20 )

F_Get_Byte_from_Buffer( 1, 0x8000 )

F_Get_Byte_from_Buffer( 2, 0x8000 )

F_Get_Byte_from_Buffer( 1, 0x8001 )

F_Get_Byte_from_Buffer( 2, 0x8001 )

........................

F_Get_Byte_from_Buffer( 1, 0x801F )

F_Get_Byte_from_Buffer( 2, 0x801F )

F_Close_Target_Device()

quit()

Page 87: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 87

List of command line instructions

quit() ;close the command interpreter program

help() ;display list below

F_Trace_ON()

F_Trace_OFF()

F_OpenInstances( no )

F_CloseInstances()

F_OpenInstancesAndFPAs( "FileName" )

F_Set_FPA_index( fpa )

F_Get_FPA_index()

F_LastStatus( fpa )

F_DLLTypeVer()

F_Multi_DLLTypeVer()

F_Check_FPA_access(index )

F_Get_FPA_SN( fpa )

F_APIDLL_Directory( "APIDLLpath" )

F_Initialization()

F_DispSetup()

F_Close_All()

F_Power_Target( OnOff )

F_Reset_Target()

F_Report_Message()

F_ReadCodeFile( file_format, "FileName" )

F_Get_CodeCS( dest )

F_ConfigFileLoad( "filename" )

F_SetConfig( index, data )

F_GetConfig( index )

F_Put_Byte_to_Buffer( addr, data )

F_Get_Byte_from_Buffer( addr )

F_Clr_Code_Buffer()

F_Put_Byte_to_Code_Buffer( addr, data )

F_Get_Byte_from_Code_Buffer( addr )

F_Put_IEEEAddr64_to_Buffer("Hex data string")

F_Get_IEEEAddr64_from_Buffer( )

F_AutoProgram( 0 )

Page 88: FlashPro-CC Flash Programmer · 2019. 6. 1. · Remote Control Programming User’s Guide PM024A02 Rev.2 12 The main FlashProCC-FPAsel.dll (Multi-FPA selector) allows to transfer

Remote Control Programming User’s Guide PM024A02 Rev.2 88

F_Verify_Lock_Bits()

F_Memory_Erase( mode )

F_Memory_Blank_Check()

F_Memory_Write( mode )

F_Memory_Verify( mode )

F_Memory_Read()

F_Write_IEEE_Address()

F_Read_IEEE_Address()

F_Write_Lock_Bits()

F_Open_Target_Device()

F_Close_Target_Device()

F_Segment_Erase( address )

F_Sectors_Blank_Check( start_addr, stop_addr )

F_Copy_Buffer_to_Flash( start_addr, size )

F_Flash_to_Buffer( start_addr, size )

F_Write_Byte_to_XRAM( addr, data )

F_Read_Byte_from_XRAM( addr )

F_Write_Byte_to_direct_RAM( addr, data )

F_Read_Byte_from_direct_RAM( addr )

F_Copy_Buffer_to_XRAM( start_addr, size )

F_Copy_XRAM_to_Buffer( start_addr, size )

F_Copy_Buffer_to_direct_RAM( start_addr, size )

F_Copy_direct_RAM_to_Buffer( start_addr, size )

F_Set_PC_and_RUN( xram_en, PC_addr )

F_Get_MCU_Data(type )

F_Get_Targets_Vcc()

F_Disable_FPA_index( fpa )

F_Enable_FPA_index( fpa )

See chapter 4 for detailed description of the instructions listed above.

Note: Not all instructions listed in the chapter 4 are implemented in the command line

interpreter. For example - all instructions uses pointers are not implemented, however

this is not limiting the access to all features of the API-DLLs, because all instructions

uses pointers are implemented also in the simpler way without pointers.