FIXTURE REMOVER KIT When marginal bone loss occurs, implant placement and GBR can be done right after the implant removal. Implant can be simply removed even in broken or osseointegrated cases. No bone damage and no dental trauma in patients occur. Trephine drill is unnecessary. Applied to any kinds of implants. When implant is placed in the wrong direction, it is possible to pull implant out simply. Key Points of Neo Fixture Remover kit 2 FR kit is a tool for removing stopped implant caused by excessive torque during insertion or other several reasons. FR kit 1 Neobiotech Co.,Ltd 104, 24 / 102, 103, 104-1, 104-2, 105, 106, 205, 212, 312, 509, 510, 511, 10F, 36 Digital-ro 27-gil, Guro-gu, Seoul, Korea Tel 82-2-582-2885, Fax 82-2-582-2883 www.neobiotech.com / Made in Korea

Upload: others

Post on 02-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FIXTURE REMOVER - Neobiotech... / Made in Korea Dongbang Acuprime 1 Forrest Units, Hennock Road East, Marsh Barton, Exeter EX2 8RU, UK Tel +44 1392-829500 Fax +44 1392-829232 Note

FIXTUREREMOVER

KIT

• When marginal bone loss occurs, implant placement and GBR can be done right after the implant removal. • Implant can be simply removed even in broken or osseointegrated cases. • No bone damage and no dental trauma in patients occur. • Trephine drill is unnecessary. • Applied to any kinds of implants. • When implant is placed in the wrong direction, it is possible to pull implant out simply.

Key Points of Neo Fixture Remover kit2 • FR kit is a tool for removing stopped implant caused by excessive torque during insertion or other several reasons.

FR kit1

Neobiotech Co.,Ltd 104, 24 / 102, 103, 104-1, 104-2, 105, 106, 205, 212, 312, 509, 510, 511, 10F, 36 Digital-ro 27-gil,Guro-gu, Seoul, Korea Tel 82-2-582-2885, Fax 82-2-582-2883 www.neobiotech.com / Made in Korea

Page 2: FIXTURE REMOVER - Neobiotech... / Made in Korea Dongbang Acuprime 1 Forrest Units, Hennock Road East, Marsh Barton, Exeter EX2 8RU, UK Tel +44 1392-829500 Fax +44 1392-829232 Note

Fixture Remover Kit Technique Guide

Fixture Remover Kit Clinical Case

Torque Wrench

Screw Driver

Fixture RemoverScrew

Fixture Remover

1

3 4

2

Failed implant

Left turn Close

Right turn Close

Clear

Neobiotech Co.,Ltd104, 24 / 102, 103, 104-1, 104-2, 105, 106, 205, 212, 312, 509, 510, 511, 10F, 36 Digital-ro 27-gil, Guro-gu, Seoul, Korea Tel 82-2-582-2885, Fax 82-2-582-2883www.neobiotech.com / Made in Korea

Dongbang Acuprime1 Forrest Units, Hennock Road East, Marsh Barton, Exeter EX2 8RU, UKTel +44 1392-829500 Fax +44 1392-829232

NoteFR kit is tool for removing stopped implant causes by excessivetorque during insertion or implant in lost bone easily, it’s designed for implant with the same diameter after removing implant, inserting new.

Ordering informationCatalog Number Description

FRKIT Fixture Remover Kit