fire_ul_fm

Upload: liaomarco

Post on 03-Jun-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/11/2019 Fire_ul_fm

    1/12

    Va l ves & Hydrants

    fo r F i re F igh t ing

    UL/ULC L i s ted and FM Approved

    A V K I N T E R N A T I O N A L A / S

  • 8/11/2019 Fire_ul_fm

    2/12

    Fire plays a decisive part in our developement ashuman beings. Under control it is invaluable, but

    out of control it can be devastating.

    Brave firemen risk their lives to extinguish fires. They rely fully on

    their equipment to function perfectly when needed. Therefore it

    is crucial that the products installed are highly reliable, are easy

    to maintain and last a lifetime. AVK is a leading suppliers of

    high quality hydrants and valves for fire fighting and sprinkler

    systems. Our unique design and wide product range is based

    on the needs of customers worldwide. We offer a wide range of

    high quality valves and hydrants which, along with a series of

    accessories, build the optimum solution.

    The complete fire fighting package complies with international

    standards and consists of hydrants, NRS post indicator valves,

    hand wheel operated OS&Y gate valves, post and wall indicators,

    all UL/ULC listed and FM approved. Furthermore AVK holds VDS

    approval for NRS hand wheel operated gate valves.

    AV K B u i l d s L o n g L i f e a n d G o o d E c o n o m y

    i n t o y o u r F i r e F i g h t i n g S y s t e m s

    Valves to DIN Standard

    Series 06/35

    Gate valve with positionindicator

    Post Indicators to UL and

    FM Standard

    Series 34

    Post indicator

    Wall post indicator

    Hydrants to AWWA

    Standard

    Series 24

    Wet barrel fire hydrant

    Series 27

    Dry barrel fire hydrant,modern style

    Dry barrel fire hydrant,nostalgic style

    Valves to AWWA Standard

    Series 25

    Gate valve for post indicator

    Gate valve with rising stem

    Series 45

    Gate valve

  • 8/11/2019 Fire_ul_fm

    3/12

  • 8/11/2019 Fire_ul_fm

    4/12

    Dry bar re l hydrants

    Ser ies 27 and Ser ies 24

    Series 27/00 dry barrel fire hydrant is primarilydesigned for frost areas, where the water main is

    located below ground frost zone.

    The series 27/00 dry barrel hydrant has two drain outlets located

    just above the water main level. The main valve disc is designed

    with the purpose of flushing the drain channels for soil and other

    impurities during opening. These impurities could lead to dama-

    ge of the main valve disk. After turning the operation key 2 to 3

    times the drain will stop flushing and the barrel will be filled with

    water, which will flow directly into the hoses and pumper hose

    or whatever is connected. Furthermore when the hydrant is

    closed after service the barrel will drain the water through the

    drain holes in the base. Therefore it is important to make sure

    that the base is surrounded by gravel allowing the hydrant to

    drain and flush without washing off the soil. If not, this could

    result in undermining of the pavement.

    Series 24 wet barrel fire hydrant is designed for

    non frost areas.

    The series 24 wet barrel hydrant is designed with the shut-off

    device directly at the outflow nozzle for hose or pumper connec-

    tion. This means that the hydrant is constantly filled with water

    and thus under pressure.

    The hydrant is mounted directly on the water main, giving full

    water pressure instantaniously when needed.

    Only after 1/8turns on the stem the water starts to flow, and

    after 12 turns the full flow capacity can be held against the fire.

    The hydrant is not for use where the temperature may come

    below 0C, due to the risk of frost bursting.

    In order to service and maintain the hydrant, we

    recommend installing an isolating gate valve on the

    upstream side.

  • 8/11/2019 Fire_ul_fm

    5/12

    5

    AVK dry or wet barrel fire hydrants meet or exceedAWWA C-502 and are all UL/ULC listed and FM

    approved. Both types of fire hydrants are designed

    for high performance, easy repair and minimum

    end user costs for labor and inventory.

    Series 27

    Series 27 are available in a modern or nostalgic design. All the

    AVK hydrants offer a numerous features including:

    Hydrant serviceable under pressure

    Light-weight, inexpensive hydrant

    tools available

    Ductile iron nozzle section, barrel

    section and base

    High pressure rating - 17.2 bar

    (250 PSI)

    Electrostatically applied polyester

    coating

    360 degree nozzle section rotationpossible

    Removable nozzles secured with

    external stainless steel allen screw

    Travel stop nut in the nozzle section

    for additional safety

    Pumper nozzle can be changed from

    4" - 41/2"

    Nozzles available in any thread

    configuration

    Traffic flange designed for easy repair

    Stainless steel traffic coupling desig-

    ned for longer operational life and

    high corrosion resistance

    Extensions available in lengths from

    6" - 60", bury depths 2' - 13'

    Patented AVK main valve design

    -1 piece replaces up to 13 pieces

    Ductile iron core fully encapsulated with rubber. Completely

    corrosion resistant (stop pins of stainless steel)

    51/4" valve opening for high flow rating

    360 degree all bronze drain channel

    Inlet shoe can be easily changed - available in most configurati-

    ons (MJ, FL, PO)

    AVK Dry Bar re l F i re Hydrants a re

    Des igned fo r H igh Per formance

    Series 84/60

    The series 84/60 monitor hydrant is particularly made for fire

    fighting in the chemical and petro-chemical industry, for refine-

    ries, tank farms, and airports where large quantities of explosive,

    flammable liquids are handled and thereby constitute a risk.

    The hydrant is supplied with two 2 1/2 hose nozzles and one

    4 pumper nozzle. The nozzles are supplied with

    the patented Easy-open system that makes

    an easy and fast opening of

    the nozzle possible - even at

    high pressure.

    Horizontally the hydrant turns 360

    continuously variable, and vertically the

    monitor can be adjusted from 45 to 70

    - also continuously variable.

    The Monitors HH365 and HH366 are

    both PN 16. They have a capacity of

    2000 respectively 3000 litres/hour and

    are suitable for both water and foam.

    The capacity of the spray nozzle is adjustable from

    1100 to 3000 litres/hour at 8 bar. Furthermore, the

    monitor can be supplied with a self-priming foam pipe,

    and the foam blend can be continuously variable adjusted from

    2-6%.

    Maintenance/repair of the hydrant can be made on location.

    The well-known ball shut-off principal allows replacement of the

    inner parts of the hydrant under full pressure without using spe-

    cial tools. In this way, the hydrant does not have to be isolated

    from the ring main. The spindle rod is made of stainless steel, and

    the plug is made of polyamide GTW synthetic elastomer.

  • 8/11/2019 Fire_ul_fm

    6/12

    Post or wall indicators are mounted end to endwith the extension spindel connecting the valve.

    It is mounted in places where direct access is

    impossible. It could be gate valves mounted on

    a water ring main in a factory area, such as oil

    refineries, chemical plants or airports.

    The post indicator indicates if the mating valve is in open or

    closed position. According to government regulations it must

    be easy for firemen to see if the valve is open or closed, even at

    a long distance. The post indicator signs OPEN AND SHUT are

    mounted on the target according to clear locations and accordingto valve size.

    P o s t I n d i c a t o r s

  • 8/11/2019 Fire_ul_fm

    7/12

    7

    The post indicator valves are used for under-ground installation in fire fighting systems. The

    post indicator flange is incorporated in the top

    gland giving a compact design.

    The post indicator indicates the position of the wedge, whether

    it is open or closed.

    The basic valve construction is, like valves for water supply,

    characterized by a fully rubber coated wedge, full and straight

    bore, low torque operation and O-ring stem seals exchangeable

    under pressure.

    The valves are available with flanges, mechanical joints or push-on

    joint ends in DN 100-300 (4" - 12").

    P o s t I n d i c a t o r V a l v e s

    Picture: MINIMAX GmbH

    Resil ient seated gate

    valves

    A published test from

    City of Roseville, US, has

    proved that impurities up

    to 8.7 mm can be

    handled by a DN 150 mm

    valve without any problems.

    The same test has also

    proved that the unique

    AVK rubber quality EDK

    70 is the only rubber

    quality which instantly

    returns to the original

    shape when the valve is

    opened again.

  • 8/11/2019 Fire_ul_fm

    8/12

    Series 06/35 - The light weight flanged gate valve isvery suitable for use in fire fighting systems as an

    isolating gate valve for maintenance purpose.

    The pin indicator indicates the wedge position. Micro switches

    for remote indication of the wedge in open or closed position

    are available as an optional extra.

    The basic valve construction is, like valves for water supply,

    characterized by a fully rubber coated wedge, full and straight

    bore and 3 independant stem seals.

    GGG-50 Face to face to DIN 3202, F4

    DN 50 - 300

    VdS-approved

    Series 25 and Series 45 - The OS&Y or NRS gate

    valves with flanges are used in above ground

    installations. Due to the rising stem it is easy to

    recognize the valve position, open or closed, even

    at a distance.

    The basic valve design is, like valves for water supply, characteri-

    zed by a fully rubber coated wedge, full and straight bore, low

    torque operation and O-ring stem seals exchangeable under

    pressure.

    DN 65 - 300 (21/2" - 12")

    UL-listed, FM-approved

    Standard stem sealing system

    for water applications to

    AWWA standard.

    NBR wiper ring

    polyamid bearing with 2 O-rings,

    exchangeable under pressure

    with the valve fully opened.

    O-ring protects the antifrictionwashers

    Optional stem material:

    Low zinc bronze

    Standard stem sealing system

    for water applications to DIN

    standard.

    NBR wiper ring

    polyamid bearing with 4 O-rings

    EPDM rubber manchette

    Gate Va l ves Ser ies 06/35 (D IN ) ,

    Ser ies 25 (AWWA) and Ser ies 45 (AWWA)

    Picture: MINIMAX GmbH

    AVK resilient seated gate valves are designed with

    a fully vulcanised rubber wedge - internally and

    externally.

    With this design no iron parts are exposed to the medium and

    the excellent rubber vulcanisation prevents creeping corrosion

    underneath the rubber. The rubber is vulcanized onto the wedge

    by AVK GUMMI A/S, one of Europe's leading manufacturers of

    high technology moulded rubber components.

    The high quality of AVK rubber is characterized by:

    Smell and taste response characteristics highly suitable for

    the food industry

    Very low deformation ensuring optimum sealing

    High impact resistance preventing corrosion

    Low friction ensuring low closing torques

    EPDM rubber for water supply, NBR rubber for gas supply

  • 8/11/2019 Fire_ul_fm

    9/12

    9

    Picture: MINIMAX GmbH

    Dry pipe system

    for rooms subject to frost hazard

    Wet pipe system

    for frost-protected rooms

    Pump suction tank

    Control cabinet

    Fire pump

    Jockey pumpCompressor unit

    Water pressure vessel

    Dry pipe valve setWet pipe valve set

    Automatic feedmechanism

    Town main

    Escutcheon

    Sprinkler pipework installed visible -upright sprinklers with riserPipework installed abovesuspended ceiling -pendent sprinklers

    Townmain

    Sprinkler pipework installed visible -upright sprinklers with riser Pipeworks installed abovesuspended ceiling -pendent dry sprinklers

    Feeding tank

    Manifold

    Over-

    flow

    drain

    Test linefor pump

    Suction pipe

    SPR

    INKLER-ALA

    RM

    SPR

    INKLER-ALA

    RM

  • 8/11/2019 Fire_ul_fm

    10/12

    0

    Hydrants , Ga te Va l ves

    and Ind ica tor Posts fo r F i re F igh t ing

    Series 27/00

    Dry barrel fire hydrant,modern styleBury depth 21/2' - 10'250 PSI, GGG-50UL/ULC listed,FM approved

    Inlet options: 4"-6" flanged 4"-6" mechanical joint 6" push-on

    Series 06/35

    Flanged gate valvewith position indi-catorDN 50-300PN 10 or 16GGG-50VdS approved

    Series 25

    Flanged gate valvefor indicator postDN 100-300, PN 16GG-25UL/ULC listed,FM approved

    Options: push-on ends or

    mechanical joint ends

    Series 25

    Flanged gate valvewith rising stem200 PSIDN 65-250: GG-25DN 300: GGG-50UL/ULC listed,FM approved

    Options: grooved ends or

    grooved/flangedends

    Series 34/00

    Post indicator,telescopic forDN 100-300 P.I.gate valves,bury depth483-2210 mmGGG-50UL/ULC listed,FM approved

    Series 34/80

    Wall post indicator,DN 100-300 P.I.gate valves,Stem length250-1250 mmGGG-50UL/ULC listed,FM approved

    Series 45

    Gate valve with groovedends and rising stemGGG-50Bonnet: GGG-50UL/ULC listed,FM approved

    Options: flanged ends or

    grooved/flangedends

    Series 25

    Flanged gate valvefor indicator postDN 50-300200 PSIGG-25UL/ULC listed,FM approved

    Options: push-on ends or

    mechanical joint ends

    Series 24

    Wet barrel fire hydrant200 PSIGGG-50UL listedFM approved

    Options: 1 x pumper 2 x hose 1 x pumper 1 x hose

    Series 27/80

    Dry barrel fire hydrant,nostalgic styleBury depth 21/2' - 10'250 PSI, GGG-50UL/ULC listed,FM approved

    Inlet options: 4"-6" flanged 4"-6" mechanical joint 6" push-on

    Series 25

    Gate valve withmechanical joint endsfor indicator postDN 50-400, 200 PSIGG-25UL/ULC listed,FM approved

    Options: flange ends or IPS

    push-on ends

  • 8/11/2019 Fire_ul_fm

    11/12

    11

    Accesso r ies

    for Hydrants and Va l ves

    Series 27/70

    Extension kit for drybarrel hydrants

    Series 24/82

    Break ring repairkit for wet barrelhydrants

    Series 04

    Stem caps for gatevalves and serviceconnection valvesDN 25-500GG-25

    Series 27/75

    Traffic section repairkit for dry barrelhydrants

    Series 27

    Tools for dry barrelhydrants

    Series 08

    Hand wheel for gatevalvesDN 50-500GG-25

    Series 24/80

    Breakable flangeunit for wet barrelhydrants

    Micro Switch forseries 06/35

    Series 84/60

    Dry barrelmonitor hydrantAccording to DIN 3222Additional ball shut offat inletDuctile iron,DN 100, PN 16

  • 8/11/2019 Fire_ul_fm

    12/12

    AVK INTERNATIONAL A/S

    Bizonvej 1, Skovby

    DK-8464 Galten, Denmark

    Tel.: +45 87 54 21 00

    Fax: +45 87 54 21 20

    e-mail: [email protected]