firefighter all vol 1

Upload: fire-library

Post on 31-May-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    1/47

    I WANT TO BE AFIREFIGHTER

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    2/47

    I WANT TO BE A APPLICANT

    FIREFIGHTER 100 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    3/47

    Which of the following results in reducedchaos and confusion, improved coordination,reduced duplication of effort and a reductionin the amount of direction needed toaccomplish tasks?

    1. Standard operating procedures2. Tactical objectives

    3. Size up4. StrategyREMOVEDREMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    4/47

    Which of the following results in reducedchaos and confusion, improved coordination,reduced duplication of effort and a reductionin the amount of direction needed toaccomplish tasks?

    1. Standard operating procedures

    ANSWER: 1 ESSENTIALS 4 TH , P 13

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    5/47

    I WANT TO BE A RECRUIT

    FIREFIGHTER 200 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    6/47

    Lightweight wood trusses will failafter exposure to fire for __ to __ minutes

    1. 5 to 10

    2. 10 to 153. 15 to 20

    4. 25 to 25

    REMOVED

    REMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    7/47

    Lightweight wood trusses will failafter exposure to fire for __ to __ minutes

    1. 5 to 10

    Answer 1 ESSENTIALS 4 TH , P 75

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    8/47

    I WANT TO BE A ROOKIE

    FIREFIGHTER 300 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    9/47

    WHEN USING AN EXTINGUISHER,ONE SHOULD:

    1. Point the nozzle upward to lob the agent gentlyonto the fire from above.

    2. Sweep the nozzle vertically while discharging

    the agent in an effort to cover the entire body of flame.

    3. Point the nozzle at the base of the flames and

    sweep it back and forth while discharging theagent.

    4. Place the nozzle as close to the fuel as possible

    in order to blow the flame off of the fuel.

    REMOVE

    REMOVE

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    10/47

    WHEN USING AN EXTINGUISHER,ONE SHOULD:

    3 Point the nozzle at the base of the flames andsweep it back and forth while discharging the

    agent.

    Answer 3 ESSENTIALS 4 TH , P 137, 142-144

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    11/47

    I WANT TO BE A PROBIE

    FIREFIGHTER 500 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    12/47

    DATA REGARDING THE ROPESCONDITION AND DATE OF LAST

    INSPECTION SHOULD BE RECORDEDON:

    1. Rope status sheet

    2. Rope maintenance record

    3. Equipment inventory log

    4. Rope log

    REMOVED

    REMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    13/47

    DATA REGARDING THE ROPESCONDITION AND DATE OF LAST

    INSPECTION SHOULD BE RECORDEDON:

    4 Rope log

    Answer 4 ESSENTIALS 4 TH , P 152

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    14/47

    I WANT TO BE A ENGINE

    COMPANY FIREFIGHTER 1,000 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    15/47

    THE AIR CHISEL IS WELL SUITED FOR ALL OF THE FOLLOWING

    APPLICATIONS EXCEPT ONE. CHOOSETHE EXCEPTION.

    1. Opening a car roof.2. Use in the presence of flammable vapors.

    3. Cutting sheet metal.

    4. Cutting a car roof support posts.

    REMOVED

    ROMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    16/47

    THE AIR CHISEL IS WELL SUITED FOR ALL OF THE FOLLOWING

    APPLICATIONS EXCEPT ONE. CHOOSETHE EXCEPTION.

    2 Use in the presence of flammable vapors.

    Answer 2 ESSENTIALS 4 TH , P 193

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    17/47

    I WANT TO BE A TRUCKIE

    FIREFIGHTER 2,000 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    18/47

    A SELF-CLOSING FIRE DOOR:

    1. Remains open until heat activates the closingdevice.

    2. Returns to the closed position after beingopened.

    3. Can be forced by inserting a prybar near thelatch

    4. Can be made to stay open by replacing thefusible link

    REMOVED

    REMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    19/47

    A SELF-CLOSING FIRE DOOR:

    2 Returns to the closed position after being

    opened.

    Answer 2 ESSENTIALS 4 TH , P 250

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    20/47

    I WANT TO BE A DRIVER

    FIREFIGHTER 4,000 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    21/47

    HOW FAR SHOULD THE TOP OF THELADDER EXTEND BEYOND THE EDGE

    OF A ROOF?

    1. TWO RUNGS

    2. THREE RUNGS

    3. FOUR RUNGS

    4. FIVE RUNGS

    REMOVED

    REMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    22/47

    HOW FAR SHOULD THE TOP OF THELADDER EXTEND BEYOND THE EDGE

    OF A ROOF?

    4 FIVE RUNGS

    Answer 4 ESSENTIALS 4 TH , P 291

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    23/47

    I WANT TO BE A ENGINEER

    FIREFIGHTER 8,000 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    24/47

    FORCED VENTILATION IS

    ACCOMPLISHED:

    1. Mechanically and electrically

    2. Hydraulically and mechanically

    3. Pneumatically and hydraulically

    4. Intrinsically and extrinsically

    REMOVED

    REMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    25/47

    FORCED VENTILATION ISACCOMPLISHED:

    1. Mechanically and electrically

    Answer 1 ESSENTIALS 4TH

    , P366

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    26/47

    I WANT TO BE A LIEUTENANT

    FIREFIGHTER 16,000 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    27/47

    ALL OF THE STATEMENTS ABOUT TWOFIREFIGHTERS OPERATING A LARGEHOSELINE ARE CORRECT EXCEPT ONE.CHOOSE THE EXCEPTION .

    1. Some means of anchoring the hose will be needed toabsorb some of the nozzle kickback.

    2. Rope or web hose tools (hose straps) may assist inanchoring the hose.

    3. The backup firefighter should be about ten feet behind

    the firefighter on the nozzle.4. The hose may be anchored by having the backup

    firefighter kneel on the hoseline while holding it.

    REMOVED

    REMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    28/47

    ALL OF THE STATEMENTS ABOUT TWOFIREFIGHTERS OPERATING A LARGEHOSELINE ARE CORRECT EXCEPT ONE.CHOOSE THE EXCEPTION .

    3 The backup firefighter should be about ten feet behindthe firefighter on the nozzle.

    Answer 3 ESSENTIALS 4 TH , P 435-436

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    29/47

    I WANT TO BE A CAPTAIN

    FIREFIGHTER 32,000 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    30/47

    HIGH-EXPANSION FOAMS ARE WELL

    SUITED FOR:

    1. Hydrocarbon fuels

    2. Polar solvents3. Confined space fires

    4. Vapor suppression on unignited spills

    REMOVED

    REMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    31/47

    HIGH-EXPANSION FOAMS ARE WELL

    SUITED FOR:

    3 Confined space fires

    Answer 3 ESSENTIALS 4 TH , P 503

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    32/47

    I WANT TO BE A STAFFBATTALION CHIEF

    FIREFIGHTER

    64,000 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    33/47

    ANSI STANDARD Z87.1 ADDRESSES:

    1. Hearing protection

    2. Safety shoe construction3. Firefighter safety uniform standards

    4. Eye protection

    REMOVEDREMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    34/47

    ANSI STANDARD Z87.1 ADDRESSES:

    4 Eye protection

    Answer 4 ESSENTIALS 4 TH , P 82

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    35/47

    I WANT TO BE A OPERATIONSBATTALION CHIEF

    FIREFIGHTER

    125,000 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    36/47

    A PROTECTED PREMISES FIREALARM SYSTEM USED TO BE KNOWNAS:

    1. Proprietary system2. Audible alarm

    3. Local alarm system

    4. Building alarm

    REMOVED

    REMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    37/47

    A PROTECTED PREMISES FIREALARM SYSTEM USED TO BE KNOWNAS:

    3 Local alarm system

    Answer 3 ESSENTIALS 4TH

    , 559

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    38/47

    I WANT TO BE A SENIOR

    FIREFIGHTER 250,000 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    39/47

    ACCORDING TO NFPA STANDARD, ANORANGE HYDRANT SHOULD FLOW

    ____ GPM.

    1. Less than 5002. 500 to 1000

    3. 1000 to 1500

    4. 1500 or more

    REMOVEDREMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    40/47

    ACCORDING TO NFPA STANDARD, ANORANGE HYDRANT SHOULD FLOW

    ____ GPM.

    2 500 to 1000

    Answer 2 ESSENTIALS 4TH

    , P 388

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    41/47

    I WANT TO BE A TRAINING

    OFFICER FIREFIGHTER 500,000 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    42/47

    UNPROTECTED STEEL STRUCTURALMEMBERS ELONGATE WHEN

    EXPOSED TO TEMPERATURES OF ASLOW AS ____ DEGREES FAHRENHEIT.

    1. 6002. 800

    3. 1,000

    4. 1,200

    REMOVED

    REMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    43/47

    UNPROTECTED STEEL STRUCTURALMEMBERS ELONGATE WHEN

    EXPOSED TO TEMPERATURES OF ASLOW AS ____ DEGREES FAHRENHEIT.

    3 1,000

    Answer 3 ESSENTIALS 4 TH , P545

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    44/47

    I WANT TO BE A LINE

    FIREFIGHTER 1,000,000 POINT QUESTION

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    45/47

    THE UNIT OF VOLUME IN SI IS THE:

    1. Square foot

    2. Cubic yard

    3. Square meter

    4. Cubic meter

    REMOVEDREMOVED

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    46/47

    THE UNIT OF VOLUME IN SI IS THE:

    4 Cubic meter

    Answer 4 ESSENTIALS 4 TH , P 34

  • 8/14/2019 FIREFIGHTER ALL VOL 1

    47/47

    CONGRATULATIONSYOU ARE ONEIN A MILLION

    ALINE

    FIREFIGHTER